Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Blood ; 141(25): 3055-3064, 2023 06 22.
Artículo en Inglés | MEDLINE | ID: mdl-37001036

RESUMEN

The objective of this study is to externally validate the clinical positron emission tomography (PET) model developed in the HOVON-84 trial and to compare the model performance of our clinical PET model using the international prognostic index (IPI). In total, 1195 patients with diffuse large B-cell lymphoma (DLBCL) were included in the study. Data of 887 patients from 6 studies were used as external validation data sets. The primary outcomes were 2-year progression-free survival (PFS) and 2-year time to progression (TTP). The metabolic tumor volume (MTV), maximum distance between the largest lesion and another lesion (Dmaxbulk), and peak standardized uptake value (SUVpeak) were extracted. The predictive values of the IPI and clinical PET model (MTV, Dmaxbulk, SUVpeak, performance status, and age) were tested. Model performance was assessed using the area under the curve (AUC), and diagnostic performance, using the positive predictive value (PPV). The IPI yielded an AUC of 0.62. The clinical PET model yielded a significantly higher AUC of 0.71 (P < .001). Patients with high-risk IPI had a 2-year PFS of 61.4% vs 51.9% for those with high-risk clinical PET, with an increase in PPV from 35.5% to 49.1%, respectively. A total of 66.4% of patients with high-risk IPI were free from progression or relapse vs 55.5% of patients with high-risk clinical PET scores, with an increased PPV from 33.7% to 44.6%, respectively. The clinical PET model remained predictive of outcome in 6 independent first-line DLBCL studies, and had higher model performance than the currently used IPI in all studies.


Asunto(s)
Linfoma de Células B Grandes Difuso , Recurrencia Local de Neoplasia , Humanos , Pronóstico , Estudios Retrospectivos , Tomografía de Emisión de Positrones , Linfoma de Células B Grandes Difuso/diagnóstico , Factores de Riesgo , Fluorodesoxiglucosa F18
2.
Eur J Nucl Med Mol Imaging ; 49(3): 943-952, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34476551

RESUMEN

PURPOSE: MYC gene rearrangements in diffuse large B-cell lymphoma (DLBCL) patients are associated with poor prognosis. Our aim was to compare patterns of 2[18F]fluoro-2-deoxy-D-glucose positron emission tomography computed tomography (PET/CT) response in MYC + and MYC- DLBCL patients. METHODS: Interim PET/CT (I-PET) and end of treatment PET/CT (EoT-PET) scans of 81 MYC + and 129 MYC- DLBCL patients from 2 HOVON trials were reviewed using the Deauville 5-point scale (DS). DS1-3 was regarded as negative and DS4-5 as positive. Standardized uptake values (SUV) and metabolic tumor volume (MTV) were quantified at baseline, I-PET, and EoT-PET. Negative (NPV) and positive predictive values (PPV) were calculated using 2-year overall survival. RESULTS: MYC + DLBCL patients had significantly more positive EoT-PET scans than MYC- patients (32.5 vs 15.7%, p = 0.004). I-PET positivity rates were comparable (28.8 vs 23.8%). In MYC + patients 23.2% of the I-PET negative patients converted to positive at EoT-PET, vs only 2% for the MYC- patients (p = 0.002). Nine (34.6%) MYC + DLBCL showed initially uninvolved localizations at EoT-PET, compared to one (5.3%) MYC- patient. A total of 80.8% of EoT-PET positive MYC + patients showed both increased lesional SUV and MTV compared to I-PET. In MYC- patients, 31.6% showed increased SUV and 42.1% showed increased MTV. NPV of I-PET and EoT-PET was high for both MYC subgroups (81.8-94.1%). PPV was highest at EoT-PET for MYC + patients (61.5%). CONCLUSION: MYC + DLBCL patients demonstrate aberrant PET response patterns compared to MYC- patients with more frequent progression during treatment after I-PET negative assessment and new lesions at sites that were not initially involved. TRIAL REGISTRATION NUMBER AND DATE OF REGISTRATION: HOVON-84: EudraCT: 2006-005,174-42, retrospectively registered 01-08-2008. HOVON-130: EudraCT: 2014-002,654-39, registered 26-01-2015.


Asunto(s)
Linfoma de Células B Grandes Difuso , Tomografía Computarizada por Tomografía de Emisión de Positrones , Fluorodesoxiglucosa F18 , Reordenamiento Génico , Humanos , Linfoma de Células B Grandes Difuso/diagnóstico por imagen , Linfoma de Células B Grandes Difuso/genética , Linfoma de Células B Grandes Difuso/terapia , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones , Pronóstico , Estudios Retrospectivos
3.
Eur J Nucl Med Mol Imaging ; 48(9): 2856-2870, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33517517

RESUMEN

PURPOSE: In order to achieve comparability of image quality, harmonisation of PET system performance is imperative. In this study, prototype harmonisation criteria for PET brain studies were developed. METHODS: Twelve clinical PET/CT systems (4 GE, 4 Philips, 4 Siemens, including SiPM-based "digital" systems) were used to acquire 30-min PET scans of a Hoffman 3D Brain phantom filled with ~ 33 kBq·mL-1 [18F]FDG. Scan data were reconstructed using various reconstruction settings. The images were rigidly coregistered to a template (voxel size 1.17 × 1.17 × 2.00 mm3) onto which several volumes of interest (VOIs) were defined. Recovery coefficients (RC) and grey matter to white matter ratios (GMWMr) were derived for eroded (denoted in the text by subscript e) and non-eroded grey (GM) and white (WM) matter VOIs as well as a mid-phantom cold spot (VOIcold) and VOIs from the Hammers atlas. In addition, left-right hemisphere differences and voxel-by-voxel differences compared to a reference image were assessed. RESULTS: Systematic differences were observed for reconstructions with and without point-spread-function modelling (PSFON and PSFOFF, respectively). Normalising to image-derived activity, upper and lower limits ensuring image comparability were as follows: for PSFON, RCGMe = [0.97-1.01] and GMWMre = [3.51-3.91] for eroded VOI and RCGM = [0.78-0.83] and GMWMr = [1.77-2.06] for non-eroded VOI, and for PSFOFF, RCGMe = [0.92-0.99] and GMWMre = [3.14-3.68] for eroded VOI and RCGM = [0.75-0.81] and GMWMr = [1.72-1.95] for non-eroded VOI. CONCLUSIONS: To achieve inter-scanner comparability, we propose selecting reconstruction settings based on RCGMe and GMWMre as specified in "Results". These proposed standards should be tested prospectively to validate and/or refine the harmonisation criteria.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Tomografía Computarizada por Tomografía de Emisión de Positrones , Encéfalo/diagnóstico por imagen , Fluorodesoxiglucosa F18 , Humanos , Fantasmas de Imagen , Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X
4.
Eur J Nucl Med Mol Imaging ; 48(2): 509-520, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32789599

RESUMEN

PURPOSE: The detection of lymph-node metastases (N1) with conventional imaging such as magnetic resonance imaging (MRI) and computed tomography (CT) is inadequate for primarily diagnosed prostate cancer (PCa). Prostate-specific membrane antigen (PSMA) PET/CT is successfully introduced for the staging of (biochemically) recurrent PCa. Besides the frequently used 68gallium-labelled PSMA tracers, 18fluorine-labelled PSMA tracers are available. This study examined the diagnostic accuracy of 18F-DCFPyL (PSMA) PET/CT for lymph-node staging in primary PCa. METHODS: This was a prospective, multicentre cohort study. Patients with primary PCa underwent 18F-DCFPyL PET/CT prior to robot-assisted radical prostatectomy (RARP) with extended pelvic lymph-node dissection (ePLND). Patients were included between October 2017 and January 2020. A Memorial Sloan Kettering Cancer Centre (MSKCC) nomogram risk probability of ≥ 8% of lymph-node metastases was set to perform ePLND. All images were reviewed by two experienced nuclear physicians, and were compared with post-operative histopathologic results. RESULTS: A total of 117 patients was analysed. Lymph-node metastases (N1) were histologically diagnosed in 17/117 patients (14.5%). The sensitivity, specificity, positive predictive value and negative predictive value for the 18F-DCFPyL PET/CT detection of pelvic lymph-node metastases on a patient level were 41.2% (confidence interval (CI): 19.4-66.5%), 94.0% (CI 86.9-97.5%), 53.8% (CI 26.1-79.6%) and 90.4% (CI 82.6-95.0%), respectively. CONCLUSION: 18F-DCFPyL PET/CT showed a high specificity (94.4%), yet a limited sensitivity (41.2%) for the detection of pelvic lymph-node metastases in primary PCa. This implies that current PSMA PET/CT imaging cannot replace diagnostic ePLND. Further research is necessary to define the exact place of PSMA PET/CT imaging in the primary staging of PCa.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata , Estudios de Cohortes , Disección , Humanos , Masculino , Estadificación de Neoplasias , Estudios Prospectivos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología
5.
World J Urol ; 39(7): 2439-2446, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33079250

RESUMEN

PURPOSE: In primary prostate cancer (PCa) patients, accurate staging and histologic grading are crucial to guide treatment decisions. 18F-DCFPyL (PSMA)-PET/CT has been successfully introduced for (re)staging PCa, showing high accuracy to localise PCa in lymph nodes and/or osseous structures. The diagnostic performance of 18F-DCFPyL-PET/CT in localizing primary PCa within the prostate gland was assessed, allowing for PSMA-guided targeted-prostate biopsy. METHODS: Thirty patients with intermediate-/high-risk primary PCa were prospectively enrolled between May 2018 and May 2019 and underwent 18F-DCFPyL-PET/CT prior to robot-assisted radical prostatectomy (RARP). Two experienced and blinded nuclear medicine physicians assessed tumour localisation within the prostate gland on PET/CT, using a 12-segment mapping model of the prostate. The same model was used by a uro-pathologist for the RARP specimens. Based on PET/CT imaging, a potential biopsy recommendation was given per patient, based on the size and PET-intensity of the suspected PCa localisations. The biopsy recommendation was correlated to final histopathology in the RARP specimen. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for clinically significant PCa (csPCa, Gleason score ≥ 3 + 4 = 7) were assessed. RESULTS: The segments recommended for potential targeted biopsy harboured csPCA in 28/30 patients (93%), and covered the highest Gleason score PCa segment in 26/30 patient (87%). Overall, 122 of 420 segments (29.0%) contained csPCa at final histopathological examination. Sensitivity, specificity, PPV and NPV for csPCa per segment using 18F-DCFPyL-PET/CT were 61.4%, 88.3%, 68.1% and 84.8%, respectively. CONCLUSIONS: When comparing the PCa-localisation on 18F-DCFPyL-PET/CT with the RARP specimens, an accurate per-patient detection (93%) and localisation of csPCa was found. Thus, 18F-DCFPyL-PET/CT potentially allows for accurate PSMA-targeted biopsy.


Asunto(s)
Antígenos de Superficie , Glutamato Carboxipeptidasa II , Lisina/análogos & derivados , Tomografía Computarizada por Tomografía de Emisión de Positrones , Prostatectomía , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Urea/análogos & derivados , Anciano , Biopsia , Estudios de Factibilidad , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Estudios Prospectivos , Neoplasias de la Próstata/cirugía
7.
Eur J Nucl Med Mol Imaging ; 47(4): 849-859, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31705176

RESUMEN

PURPOSE: One-third of patients with RAS wild-type mCRC do not benefit from anti-EGFR monoclonal antibodies. This might be a result of variable pharmacokinetics and insufficient tumor targeting. We evaluated cetuximab tumor accumulation on [89Zr]Zr-cetuximab PET/CT as a potential predictive biomarker and determinant for an escalating dosing strategy. PATIENTS AND METHODS: PET/CT imaging of [89Zr]Zr-cetuximab (37 MBq/10 mg) after a therapeutic pre-dose (500 mg/m2 ≤ 2 h) cetuximab was performed at the start of treatment. Patients without visual tumor uptake underwent dose escalation and a subsequent [89Zr]Zr-cetuximab PET/CT. Treatment benefit was defined as stable disease or response on CT scan evaluation after 8 weeks. RESULTS: Visual tumor uptake on [89Zr]Zr-cetuximab PET/CT was observed in 66% of 35 patients. There was no relationship between PET positivity and treatment benefit (52% versus 80% for PET-negative, P = 0.16), progression-free survival (3.6 versus 5.7 months, P = 0.15), or overall survival (7.1 versus 9.4 months, P = 0.29). However, in 67% of PET-negative patients, cetuximab dose escalation (750-1250 mg/m2) was applied, potentially influencing outcome in this group. None of the second [89Zr]Zr-cetuximab PET/CT was positive. Eighty percent of patients without visual tumor uptake had treatment benefit, making [89Zr]Zr-cetuximab PET/CT unsuitable as a predictive biomarker. Tumor SUVpeak did not correlate to changes in tumor size on CT (P = 0.23), treatment benefit, nor progression-free survival. Cetuximab pharmacokinetics were not related to treatment benefit. BRAF mutations, right-sidedness, and low sEGFR were correlated with intrinsic resistance to cetuximab. CONCLUSION: Tumor uptake on [89Zr]Zr-cetuximab PET/CT failed to predict treatment benefit in patients with RAS wild-type mCRC receiving cetuximab monotherapy. BRAF mutations, right-sidedness, and low sEGFR correlated with intrinsic resistance to cetuximab.


Asunto(s)
Neoplasias Colorrectales , Tomografía Computarizada por Tomografía de Emisión de Positrones , Biomarcadores , Cetuximab/metabolismo , Neoplasias Colorrectales/diagnóstico por imagen , Neoplasias Colorrectales/tratamiento farmacológico , Neoplasias Colorrectales/genética , Humanos , Mutación , Proteínas Proto-Oncogénicas B-raf/genética , Proteínas Proto-Oncogénicas p21(ras)/genética
8.
Eur J Nucl Med Mol Imaging ; 45(6): 951-961, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29362858

RESUMEN

INTRODUCTION: 3'-deoxy-3'-[18F]fluorothymidine (18F-FLT) positron emission tomography (PET) provides a non-invasive method to assess cellular proliferation and response to antitumor therapy. Quantitative 18F-FLT uptake metrics are being used for evaluation of proliferative response in investigational setting, however multi-center repeatability needs to be established. The aim of this study was to determine the repeatability of 18F-FLT tumor uptake metrics by re-analyzing individual patient data from previously published reports using the same tumor segmentation method and repeatability metrics across cohorts. METHODS: A systematic search in PubMed, EMBASE.com and the Cochrane Library from inception-October 2016 yielded five 18F-FLT repeatability cohorts in solid tumors. 18F-FLT avid lesions were delineated using a 50% isocontour adapted for local background on test and retest scans. SUVmax, SUVmean, SUVpeak, proliferative volume and total lesion uptake (TLU) were calculated. Repeatability was assessed using the repeatability coefficient (RC = 1.96 × SD of test-retest differences), linear regression analysis, and the intra-class correlation coefficient (ICC). The impact of different lesion selection criteria was also evaluated. RESULTS: Images from four cohorts containing 30 patients with 52 lesions were obtained and analyzed (ten in breast cancer, nine in head and neck squamous cell carcinoma, and 33 in non-small cell lung cancer patients). A good correlation was found between test-retest data for all 18F-FLT uptake metrics (R2 ≥ 0.93; ICC ≥ 0.96). Best repeatability was found for SUVpeak (RC: 23.1%), without significant differences in RC between different SUV metrics. Repeatability of proliferative volume (RC: 36.0%) and TLU (RC: 36.4%) was worse than SUV. Lesion selection methods based on SUVmax ≥ 4.0 improved the repeatability of volumetric metrics (RC: 26-28%), but did not affect the repeatability of SUV metrics. CONCLUSIONS: In multi-center studies, differences ≥ 25% in 18F-FLT SUV metrics likely represent a true change in tumor uptake. Larger differences are required for FLT metrics comprising volume estimates when no lesion selection criteria are applied.


Asunto(s)
Didesoxinucleósidos/farmacocinética , Neoplasias/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Tomografía de Emisión de Positrones , Reproducibilidad de los Resultados
9.
Eur J Nucl Med Mol Imaging ; 45(13): 2307-2317, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30094460

RESUMEN

BACKGROUND: The aim of this study was to assess radiomics features on pre-treatment [18F]FDG positron emission tomography (PET) as potential biomarkers for response and survival in patients with metastatic colorectal cancer (mCRC). METHODS: Patients with mCRC underwent [18F]FDG PET/computed tomography (CT) prior to first- or third-line palliative systemic treatment. Tumour lesions were semiautomatically delineated and standard uptake value (SUV), metabolically active tumour volume (MATV), total lesion glycolysis (TLG), entropy, area under the curve of the cumulative SUV-volume histogram (AUC-CSH), compactness and sphericity were obtained. RESULTS: Lesions of 47 patients receiving third-line systemic treatment had higher SUVmax, SUVpeak, SUVmean, MATV and TLG, and lower AUC-CSH, compactness and sphericity compared to 52 patients receiving first-line systemic treatment. Therefore, first- and third-line groups were evaluated separately. In the first-line group, anatomical changes on CT correlated negatively with TLG (ρ = 0.31) and MATV (ρ = 0.36), and positively with compactness (ρ = -0.27) and sphericity (ρ = -0.27). Patients without benefit had higher mean entropy (p = 0.021). Progression-free survival (PFS) and overall survival (OS) were worse with a decreased mean AUC [hazard ratio (HR) 0.86, HR 0.77] and increase in mean MATV (HR 1.15, HR 1.22), sum MATV (HR 1.14, HR 1.19), mean TLG (HR 1.16, HR 1.22) and sum TLG (HT1.12, HR1.18). In the third-line group, AUC-CSH correlated negatively with anatomical change (ρ = 0.21). PFS and OS were worse with an increased mean MATV (HR 1.27, HR 1.68), sum MATV (HR 1.35, HR 2.04), mean TLG (HR 1.29, HR 1.52) and sum TLG (HT 1.27, HR 1.80). SUVmax and SUVpeak negatively correlated with OS (HR 1.19, HR 1.21). Cluster analysis of the 10 radiomics features demonstrated no complementary value in identifying aggressively growing lesions or patients with impaired survival. CONCLUSION: We demonstrated an association between improved clinical outcome and pre-treatment low tumour volume and heterogeneity as well as high sphericity on [18F]FDG PET. Future PET imaging research should include radiomics features that incorporate tumour volume and heterogeneity when correlating PET data with clinical outcome.


Asunto(s)
Neoplasias del Colon/diagnóstico por imagen , Neoplasias del Colon/terapia , Fluorodesoxiglucosa F18 , Procesamiento de Imagen Asistido por Computador , Cuidados Paliativos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias del Colon/metabolismo , Neoplasias del Colon/patología , Supervivencia sin Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Metástasis de la Neoplasia , Estudios Retrospectivos , Carga Tumoral , Adulto Joven
10.
Dis Esophagus ; 30(2): 1-7, 2017 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-27001344

RESUMEN

18F-Fluorodeoxyglucose positron emission tomography (FDG-PET) has been investigated as a tool for monitoring response to neoadjuvant chemo- and chemoradiotherapy (CT and CRT, respectively) and as a predictor for survival in patients with esophageal cancer. In contrast to patients who undergo neoadjuvant CT, it is not known whether patients who are clinically identified as responders after neoadjuvant CRT show better disease-free survival (DFS) than patients identified as nonresponders. The aim of the study was to determine the predictive value of FDG-uptake measured prior to and early during neoadjuvant CRT. Patients treated with neoadjuvant CRT between 2004 and 2009 within a randomized trial were included. FDG-uptake was measured at baseline and after 14 days of CRT. According to the PERCIST-criteria, patients were allocated to have metabolic response, stable disease, or progression. Patients were followed until recurrence of disease or death. The predictive value of FDG-PET was determined with univariable and multivariable analysis in patients who underwent potentially curative surgery. One-hundred and six patients were included in the analysis. Minimal follow-up for surviving patients was 60 months. No significant differences in DFS were found between patients with metabolic response, stable disease, or progression, with 5-year DFS rates of 66%, 53%, and 67%, respectively (P = 0.39). Relative change in FDG uptake after 14 days of CRT is not associated with DFS in patients with esophageal cancer undergoing neoadjuvant chemoradiotherapy followed by surgery. These measurements should not be used for prognostication in this specific group of patients.


Asunto(s)
Progresión de la Enfermedad , Neoplasias Esofágicas/diagnóstico por imagen , Fluorodesoxiglucosa F18 , Tomografía de Emisión de Positrones/métodos , Radiofármacos , Adulto , Anciano , Quimioradioterapia Adyuvante/métodos , Supervivencia sin Enfermedad , Neoplasias Esofágicas/patología , Neoplasias Esofágicas/terapia , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Terapia Neoadyuvante/métodos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Resultado del Tratamiento
11.
J Viral Hepat ; 23(5): 348-57, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26768955

RESUMEN

Hepatitis C virus (HCV) infection may induce chronic fatigue and cognitive dysfunction. Virus replication was proven within the brain and HCV-positive cells were identified as microglia and astrocytes. We hypothesized that cerebral dysfunction in HCV-afflicted patients is associated with microglia activation. Microglia activation was assessed in vivo in 22 patients with chronic HCV infection compared to six healthy controls using [(11) C]-PK11195 Positron Emission Tomography (PET) combined with magnetic resonance tomography for anatomical localization. Patients were subdivided with regard to their PCR status, Fatigue Impact Scale score (FIS) and attention test sum score (ATS). A total of 12 patients (54.5%) were HCV PCR positive [of which 7 (58.3%) had an abnormal FIS and 7 (58.3%) an abnormal ATS], 10 patients (45.5%) were HCV PCR negative (5 (50%) each with an abnormal FIS or ATS). Patients without attention deficits showed a significantly higher accumulation of [(11) C]-PK11195 in the putamen (P = 0.05), caudate nucleus (P = 0.03) and thalamus (P = 0.04) compared to controls. Patients with and without fatigue did not differ significantly with regard to their specific tracer binding in positron emission tomography. Preserved cognitive function was associated with significantly increased microglia activation with predominance in the basal ganglia. This indicates a probably neuroprotective effect of microglia activation in HCV-infected patients.


Asunto(s)
Disfunción Cognitiva , Hepatitis C Crónica/complicaciones , Hepatitis C Crónica/patología , Microglía/inmunología , Adulto , Encéfalo/diagnóstico por imagen , Femenino , Humanos , Imagen por Resonancia Magnética , Persona de Mediana Edad , Tomografía de Emisión de Positrones
12.
NMR Biomed ; 29(4): 519-26, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26876426

RESUMEN

The purpose of this study was to assess whether there was an agreement between quantitative cerebral blood flow (CBF) and arterial cerebral blood volume (CBVA) measurements by [(15)O]H2O positron emission tomography (PET) and model-free QUASAR MRI. Twelve healthy subjects were scanned within a week in separate MRI and PET imaging sessions, after which quantitative and qualitative agreement between both modalities was assessed for gray matter, white matter and whole brain region of interests (ROI). The correlation between CBF measurements obtained with both modalities was moderate to high (r(2): 0.28-0.60, P < 0.05), although QUASAR significantly underestimated CBF by 30% (P < 0.001). CBVA was moderately correlated (r(2): 0.28-0.43, P < 0.05), with QUASAR yielding values that were only 27% of the [(15)O]H2O-derived values (P < 0.001). Group-wise voxel statistics identified minor areas with significant contrast differences between [(15)O]H2O PET and QUASAR MRI, indicating similar qualitative CBVA and CBF information by both modalities. In conclusion, the results of this study demonstrate that QUASAR MRI and [(15)O]H2O PET provide similar CBF and CBVA information, but with systematic quantitative discrepancies.


Asunto(s)
Arterias/fisiología , Volumen Sanguíneo/fisiología , Circulación Cerebrovascular/fisiología , Imagen por Resonancia Magnética/métodos , Tomografía de Emisión de Positrones/métodos , Agua/metabolismo , Adulto , Femenino , Hemodinámica , Humanos , Masculino , Isótopos de Oxígeno , Adulto Joven
13.
Neuroimage ; 92: 182-92, 2014 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-24531046

RESUMEN

Measurements of the cerebral blood flow (CBF) and cerebrovascular reactivity (CVR) provide useful information about cerebrovascular condition and regional metabolism. Pseudo-continuous arterial spin labeling (pCASL) is a promising non-invasive MRI technique to quantitatively measure the CBF, whereas additional hypercapnic pCASL measurements are currently showing great promise to quantitatively assess the CVR. However, the introduction of pCASL at a larger scale awaits further evaluation of the exact accuracy and precision compared to the gold standard. (15)O H2O positron emission tomography (PET) is currently regarded as the most accurate and precise method to quantitatively measure both CBF and CVR, though it is one of the more invasive methods as well. In this study we therefore assessed the accuracy and precision of quantitative pCASL-based CBF and CVR measurements by performing a head-to-head comparison with (15)O H2O PET, based on quantitative CBF measurements during baseline and hypercapnia. We demonstrate that pCASL CBF imaging is accurate during both baseline and hypercapnia with respect to (15)O H2O PET with a comparable precision. These results pave the way for quantitative usage of pCASL MRI in both clinical and research settings.


Asunto(s)
Arterias Cerebrales/diagnóstico por imagen , Arterias Cerebrales/metabolismo , Circulación Cerebrovascular , Hipercapnia/diagnóstico por imagen , Hipercapnia/metabolismo , Radioisótopos de Oxígeno/farmacocinética , Adulto , Velocidad del Flujo Sanguíneo , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Imagen de Perfusión/métodos , Tomografía de Emisión de Positrones/métodos , Radiofármacos/farmacocinética , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Marcadores de Spin , Agua/metabolismo , Adulto Joven
15.
Blood Adv ; 5(9): 2375-2384, 2021 05 11.
Artículo en Inglés | MEDLINE | ID: mdl-33944897

RESUMEN

Interim 18F-fluorodeoxyglucose positron emission tomography (Interim-18F-FDG-PET, hereafter I-PET) has the potential to guide treatment of patients with diffuse large B-cell lymphoma (DLBCL) if the prognostic value is known. The aim of this study was to determine the optimal timing and response criteria for evaluating prognosis with I-PET in DLBCL. Individual patient data from 1692 patients with de novo DLBCL were combined and scans were harmonized. I-PET was performed at various time points during treatment with rituximab plus cyclophosphamide, doxorubicin, vincristine, and prednisone (R-CHOP) therapy. Scans were interpreted using the Deauville score (DS) and change in maximum standardized uptake value (ΔSUVmax). Multilevel Cox proportional hazards models corrected for International Prognostic Index (IPI) score were used to study the effects of timing and response criteria on 2-year progression-free survival (PFS). I-PET after 2 cycles (I-PET2) and I-PET4 significantly discriminated good responders from poor responders, with the highest hazard ratios (HRs) for I-PET4. Multivariable HRs for a PET-positive result at I-PET2 and I-PET4 were 1.71 and 2.95 using DS4-5, 4.91 and 6.20 using DS5, and 2.93 and 4.65 using ΔSUVmax, respectively. ΔSUVmax identified a larger proportion of poor responders than DS5 did. For all criteria, the negative predictive value was >80%, and positive predictive values ranged from 30% to 70% at I-PET2 and I-PET4. Unlike I-PET1, I-PET3 discriminated good responders from poor responders using DS4-5 and DS5 thresholds (HRs, 2.94 and 4.67, respectively). I-PET2 and I-PET4 predict good response equally during R-CHOP therapy in DLBCL. Optimal timing and response criteria depend on the clinical context. Good response at I-PET2 is suggested for de-escalation trials, and poor response using ΔSUVmax at I-PET4 is suggested for randomized trials that are evaluating new therapies.


Asunto(s)
Linfoma de Células B Grandes Difuso , Fluorodesoxiglucosa F18 , Humanos , Linfoma de Células B Grandes Difuso/diagnóstico por imagen , Linfoma de Células B Grandes Difuso/tratamiento farmacológico , Tomografía de Emisión de Positrones , Pronóstico , Vincristina/uso terapéutico
16.
J Clin Pharm Ther ; 35(1): 63-9, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20175813

RESUMEN

BACKGROUND: Clinical positron emission tomography (PET) requires safe and effective PET radiopharmaceuticals. Tracers used for measuring oxygen consumption and blood volume are [(15)O]O(2) and [(15)O]CO, respectively. In general, these oxygen-15 labelled tracers are produced using a cyclotron that accelerates deuterons onto a target filled with (14)N(2) containing a trace of oxygen. In recent years, cyclotrons have been developed that only are capable of accelerating protons. The purpose of this study was to validate and assess such a cyclotron for production and administration of oxygen-15 labelled gasses in an hospital setting. METHODS: An RDS111 cyclotron (Siemens-CTI, Knoxville, USA) was validated for bolus production of [(15)O]O(2) and [(15)O]CO gasses. In addition, equipment was developed to administer these tracers to patients. RESULTS: Both [(15)O]O(2) and [(15)O]CO gasses could be produced in sufficient amounts, whilst meeting European Pharmacopeia requirements. Although produced oxygen-15 gasses contained a minor level of (11)C contamination, in clinical studies it was possible to correct for this contamination by delayed blood counting. CONCLUSION: An 11 MeV proton cyclotron combined with an in-house developed gas delivery system allows for the production and administration of sufficient amounts of [(15)O]-gasses for routine clinical PET studies in an hospital setting.


Asunto(s)
Monóxido de Carbono , Ciclotrones , Radioisótopos de Oxígeno , Oxígeno , Tomografía de Emisión de Positrones , Radiofármacos , Administración por Inhalación , Análisis de los Gases de la Sangre , Monóxido de Carbono/sangre , Monóxido de Carbono/química , Radioisótopos de Carbono/sangre , Radioisótopos de Carbono/química , Contaminación de Medicamentos , Humanos , Insuflación/instrumentación , Oxígeno/sangre , Oxígeno/química , Radioisótopos de Oxígeno/sangre , Radioisótopos de Oxígeno/química , Tomografía de Emisión de Positrones/instrumentación , Control de Calidad , Radiofármacos/sangre , Radiofármacos/química
17.
EJNMMI Phys ; 7(1): 20, 2020 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-32297142

RESUMEN

Optimization of injected gallium-68 (68Ga) activity for 68Ga-prostate-specific membrane antigen positron emission tomography/computed tomography (68Ga-PSMA PET/CT) studies is relevant for image quality, radiation protection, and from an economic point of view. However, no clear guidelines are available for 68Ga-PSMA studies. Therefore, a phantom study is performed to determine the highest coefficient of variation (COV) acceptable for reliable image interpretation and quantification.To evaluate image interpretation, the relationship of COV and contrast-to-noise ratio (CNR) was studied. The CNR should remain larger than five, according to the Rose criterion. To evaluate image quantification, the effect of COV on the percentage difference (PD) between quantification results of two studies was analyzed. Comparison was done by calculating the PD of the SUVmax. The maximum allowable PDSUVmax was set at 20%. The highest COV at which both criteria are still met is defined as COVmax. Of the NEMA Image Quality phantom, a 20 min/bed (2 bed positions) scan was acquired in list-mode PET (Philips Gemini TF PET/CT). The spheres to background activity ratio was approximately 9:1. To obtain images with different COV, lower activity was mimicked by reconstructions with acquisition times of 10 min/bed to 5 s/bed. Pairs of images were obtained by reconstruction of two non-overlapping parts of list-mode data.For the 10-mm diameter sphere, a COV of 25% still meets the criteria of CNRSUVmean ≥ 5 and PDSUVmax ≤ 20%. This phantom scan was acquired with an acquisition time of 116 s and a background activity concentration of 0.71 MBq/kg. Translation to a clinical protocol results in a clinical activity regimen of 3.5 MBq/kg min at injection. To verify this activity regimen, 15 patients (6 MBq/kg min) with a total of 22 lesions are included. Additional reconstructions were made to mimic the proposed activity regimen. Based on the CNRSUVmax, no lesions were missed with this proposed activity regimen.For our institution, a clinical activity regimen of 3.5 MBq/kg min at injection is acceptable, which indicates that activity can be reduced by almost 50% compared with the current code of practice. Our proposed method could be used to obtain an objective activity regimen for other PET/CT systems and tracers.

19.
Neuroimage Clin ; 28: 102504, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33395993

RESUMEN

PURPOSE: Alpha-synuclein often co-occurs with Alzheimer's disease (AD) pathology in Dementia with Lewy Bodies (DLB). From a dynamic [18F]flortaucipir PET scan we derived measures of both tau binding and relative cerebral blood flow (rCBF). We tested whether regional tau binding or rCBF differed between DLB patients and AD patients and controls and examined their association with clinical characteristics of DLB. METHODS: Eighteen patients with probable DLB, 65 AD patients and 50 controls underwent a dynamic 130-minute [18F]flortaucipir PET scan. DLB patients with positive biomarkers for AD based on cerebrospinal fluid or amyloid PET were considered as DLB with AD pathology (DLB-AD+). Receptor parametric mapping (cerebellar gray matter reference region) was used to extract regional binding potential (BPND) and R1, reflecting (AD-specific) tau pathology and rCBF, respectively. First, we performed regional comparisons of [18F]flortaucipir BPND and R1 between diagnostic groups. In DLB patients only, we performed regression analyses between regional [18F]flortaucipir BPND, R1 and performance on ten neuropsychological tests. RESULTS: Regional [18F]flortaucipir BPND in DLB was comparable with tau binding in controls (p > 0.05). Subtle higher tau binding was observed in DLB-AD+ compared to DLB-AD- in the medial temporal and parietal lobe (both p < 0.05). Occipital and lateral parietal R1 was lower in DLB compared to AD and controls (all p < 0.01). Lower frontal R1 was associated with impaired performance on digit span forward (standardized beta, stß = 0.72) and category fluency (stß = 0.69) tests. Lower parietal R1 was related to lower delayed (stß = 0.50) and immediate (stß = 0.48) recall, VOSP number location (stß = 0.70) and fragmented letters (stß = 0.59) scores. Lower occipital R1 was associated to worse performance on VOSP fragmented letters (stß = 0.61), all p < 0.05. CONCLUSION: The amount of tau binding in DLB was minimal and did not differ from controls. However, there were DLB-specific occipital and lateral parietal relative cerebral blood flow reductions compared to both controls and AD patients. Regional rCBF, but not tau binding, was related to cognitive impairment. This indicates that assessment of rCBF may give more insight into disease mechanisms in DLB than tau PET.


Asunto(s)
Enfermedad de Alzheimer , Disfunción Cognitiva , Enfermedad por Cuerpos de Lewy , Enfermedad de Alzheimer/diagnóstico por imagen , Circulación Cerebrovascular , Humanos , Enfermedad por Cuerpos de Lewy/diagnóstico por imagen , Tomografía de Emisión de Positrones , Proteínas tau
20.
Eur J Nucl Med Mol Imaging ; 36(4): 624-31, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19043704

RESUMEN

PURPOSE: Rheumatoid arthritis (RA) involves migration of macrophages into inflamed areas. (R)-[(11)C]PK11195 binds to peripheral benzodiazepine receptors, expressed on macrophages, and may be used to quantify inflammation using positron emission tomography (PET). This study evaluated methods for the quantification of (R)-[(11)C]PK11195 binding in the knee joints of RA patients. METHODS: Data from six patients with RA were analysed. Dynamic PET scans were acquired in 3-D mode following (R)-[(11)C]PK11195 injection. During scanning arterial radioactivity concentrations were measured to determine the plasma (R)-[(11)C]PK11195 concentrations. Data were analysed using irreversible and reversible one-tissue and two-tissue compartment models and input functions with various types of metabolite correction. Model preferences according to the Akaike information criterion (AIC) and correlations between measures were evaluated. Correlations between distribution volume (V(d)) and standardized uptake values (SUV) were evaluated. RESULTS: AIC indicated optimal performance for a one-tissue reversible compartment model including blood volume. High correlations were observed between V(d) obtained using different input functions (R(2)=0.80-1.00) and between V(d) obtained with one- and two-tissue reversible compartment models (R(2)=0.75-0.94). A high correlation was observed between optimal V(d) and SUV after injection (R(2)=0.73). CONCLUSION: (R)-[(11)C]PK11195 kinetics in the knee were best described by a reversible single-tissue compartment model including blood volume. Applying metabolite corrections did not increase sensitivity. Due to the high correlation with V(d), SUV is a practical alternative for clinical use.


Asunto(s)
Antineoplásicos/farmacología , Artritis Reumatoide/diagnóstico , Isoquinolinas/farmacología , Articulación de la Rodilla/diagnóstico por imagen , Adulto , Anciano , Radioisótopos de Carbono/farmacología , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Cinética , Macrófagos/metabolismo , Masculino , Persona de Mediana Edad , Tomografía de Emisión de Positrones/métodos , Receptores de GABA-A/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA