Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Autoimmun ; 139: 103056, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37302272

RESUMEN

ObjectiveMultiple spliceosome components are known autoantigens in systemic sclerosis (SSc). Here we aim to identify new and characterize rare anti-spliceosomal autoantibodies in patients with SSc without known autoantibody specificity. MethodsSera that precipitated spliceosome subcomplexes, as detected by immunoprecipitation-mass spectrometry (IP-MS), were identified from a database of 106 patients with SSc without known autoantibody specificity. New autoantibody specificities were confirmed with immunoprecipitation-western blot. The IP-MS pattern of new anti-spliceosomal autoantibodies was compared with anti-U1 RNP-positive sera of patients with different systemic autoimmune rheumatic diseases and anti-SmD-positive sera of patients with systemic lupus erythematosus (n = 24). ResultsThe NineTeen Complex (NTC) was identified and confirmed as new spliceosomal autoantigen in one patient with SSc. U5 RNP, as well as additional splicing factors, were precipitated by the serum of another patient with SSc. The IP-MS patterns of anti-NTC and anti-U5 RNP autoantibodies were distinct from those of anti-U1 RNP- and anti-SmD-positive sera. Furthermore, there was no difference in IP-MS patterns between a limited number of anti-U1 RNP-positive sera of patients with different systemic autoimmune rheumatic diseases. ConclusionAnti-NTC autoantibodies are a new anti-spliceosomal autoantibody specificity, here first identified in a patient with SSc. Anti-U5 RNP autoantibodies are a distinct but rare anti-spliceosomal autoantibody specificity. All major spliceosomal subcomplexes have now been described as target of autoantibodies in systemic autoimmune diseases.


Asunto(s)
Lupus Eritematoso Sistémico , Enfermedades Reumáticas , Esclerodermia Sistémica , Humanos , Autoanticuerpos , Empalmosomas/química , Lupus Eritematoso Sistémico/diagnóstico , Anticuerpos Antinucleares , Autoantígenos
2.
J Autoimmun ; 135: 102988, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36634459

RESUMEN

PURPOSE: In up to 20% of patients with systemic sclerosis (SSc) no known autoantibody specificity can be identified. Recently discovered autoantigens, such as telomeric repeat binding factor 1 (TERF1), as well as established autoantigens, like RuvBL1/2, are associated with telomere and telomerase biology. We aimed to identify new telomere- and telomerase-associated autoantigens in patients with SSc without known autoantibody specificity. METHODS: Unlabelled protein immunoprecipitation combined with gel-free liquid chromatography-tandem mass spectrometry (IP-MS) was performed with sera of 106 patients with SSc from two tertiary referral centres that had a nuclear pattern on HEp-2 indirect immunofluorescence without previously identified autoantibody. Telomere- or telomerase-associated proteins or protein complexes precipitated by individual sera were identified. Candidate autoantigens were confirmed through immunoprecipitation-western blot (IP-WB). A custom Luminex xMAP assay for 5 proteins was evaluated with sera from persons with SSc (n = 467), other systemic autoimmune rheumatic diseases (n = 923), non-rheumatic disease controls (n = 187) and healthy controls (n = 199). RESULTS: Eight telomere- and telomerase-associated autoantigens were identified in a total of 11 index patients, including the THO complex (n = 3, all with interstitial lung disease and two with cardiac involvement), telomeric repeat-binding factor 2 (TERF2, n = 1), homeobox-containing protein 1 (HMBOX1, n = 2), regulator of chromosome condensation 1 (RCC1, n = 1), nucleolar and coiled-body phosphoprotein 1 (NOLC1, n = 1), dyskerin (DKC1, n = 1), probable 28S rRNA (cytosine(4447)-C(5))-methyltransferase (NOP2, n = 1) and nuclear valosin-containing protein-like (NVL, n = 2). A Luminex xMAP assay for THO complex subunit 1 (THOC1), TERF2, NOLC1, NOP2 and NVL revealed high reactivity in all index patients, but also in other patients with SSc and disease controls. However, the reactivity by xMAP assay in these other patients was not confirmed by IP-WB. CONCLUSION: IP-MS revealed key telomere- and telomerase-associated proteins and protein complexes as autoantigens in patients with SSc.


Asunto(s)
Esclerodermia Sistémica , Telomerasa , Humanos , Autoantígenos , Telomerasa/metabolismo , Autoanticuerpos , Telómero , Proteínas Nucleares/metabolismo , Proteínas de Ciclo Celular/metabolismo , ATPasas Asociadas con Actividades Celulares Diversas/metabolismo , Proteínas Portadoras , ADN Helicasas/metabolismo , Proteínas de Unión al ADN/metabolismo , Proteínas de Unión al ARN
3.
Clin Chem Lab Med ; 61(7): 1199-1208, 2023 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-36989428

RESUMEN

OBJECTIVES: Detection of antinuclear antibodies (ANA) by indirect immunofluorescence assay using HEp-2 cells (HEp-2 IFA) is used to screen for various autoimmune diseases. HEp-2 IFA suffers from variability, which hampers harmonization. METHODS: A questionnaire was developed to collect information on HEp-2 IFA methodology, computer-assisted diagnosis (CAD) systems, training, inter-observer variability, quality assessment, reagent lot change control, and method verification. The questionnaire was distributed to laboratories by Sciensano (Belgium), national EASI groups (Italy, Croatia, Portugal, Estonia, Greece) and ICAP (worldwide). Answers were obtained by 414 laboratories. The results were analysed in the framework of the recent EFLM/EASI/ICAP ANA recommendations (companion paper). RESULTS: Laboratories used either HEp-2, HEp-2000, or HEp-20-10 cells and most laboratories (80%) applied the same screening dilution for children and adults. The conjugate used varied between laboratories [IgG-specific (in 57% of laboratories) vs. polyvalent]. Sixty-nine percent of CAD users reviewed the automatic nuclear pattern and 53% of CAD users did not fully exploit the fluorescence intensity for quality assurance. Internal quality control was performed by 96% of the laboratories, in 52% of the laboratories only with strongly positive samples. Interobserver variation was controlled by 79% of the laboratories. Limited lot-to-lot evaluation was performed by 68% of the laboratories. Method verification was done by 80% of the respondents. CONCLUSIONS: Even though many laboratories embrace high-quality HEp-2 IFA, substantial differences in how HEp-2 IFA is performed and controlled remain. Acting according to the EFLM/EASI/ICAP ANA recommendations can improve the global performance and quality of HEp-2 IFA and nurture harmonization.


Asunto(s)
Anticuerpos Antinucleares , Enfermedades Autoinmunes , Adulto , Niño , Humanos , Anticuerpos Antinucleares/análisis , Técnica del Anticuerpo Fluorescente Indirecta/métodos , Enfermedades Autoinmunes/diagnóstico , Pruebas Inmunológicas , Variaciones Dependientes del Observador
4.
Clin Chem Lab Med ; 61(7): 1167-1198, 2023 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-36989417

RESUMEN

OBJECTIVES: Antinuclear antibodies (ANA) are important for the diagnosis of various autoimmune diseases. ANA are usually detected by indirect immunofluorescence assay (IFA) using HEp-2 cells (HEp-2 IFA). There are many variables influencing HEp-2 IFA results, such as subjective visual reading, serum screening dilution, substrate manufacturing, microscope components and conjugate. Newer developments on ANA testing that offer novel features adopted by some clinical laboratories include automated computer-assisted diagnosis (CAD) systems and solid phase assays (SPA). METHODS: A group of experts reviewed current literature and established recommendations on methodological aspects of ANA testing. This process was supported by a two round Delphi exercise. International expert groups that participated in this initiative included (i) the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group "Autoimmunity Testing"; (ii) the European Autoimmune Standardization Initiative (EASI); and (iii) the International Consensus on ANA Patterns (ICAP). RESULTS: In total, 35 recommendations/statements related to (i) ANA testing and reporting by HEp-2 IFA; (ii) HEp-2 IFA methodological aspects including substrate/conjugate selection and the application of CAD systems; (iii) quality assurance; (iv) HEp-2 IFA validation/verification approaches and (v) SPA were formulated. Globally, 95% of all submitted scores in the final Delphi round were above 6 (moderately agree, agree or strongly agree) and 85% above 7 (agree and strongly agree), indicating strong international support for the proposed recommendations. CONCLUSIONS: These recommendations are an important step to achieve high quality ANA testing.


Asunto(s)
Anticuerpos Antinucleares , Enfermedades Autoinmunes , Humanos , Enfermedades Autoinmunes/diagnóstico , Técnica del Anticuerpo Fluorescente Indirecta/métodos , Estándares de Referencia , Línea Celular Tumoral
5.
Ann Rheum Dis ; 2022 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-35697487

RESUMEN

INTRODUCTION: Commercial assays measuring antibodies to citrullinated protein/peptide (ACPA) show poor quantitative agreement. The diagnostic industry has never adopted the International Union of Immunological Societies-Centers for Disease Control and Prevention (IUIS-CDC) ACPA reference standard. Recently, the National Institute for Biological Standards and Control (NIBSC) prepared a new candidate ACPA standard (18/204). We evaluated both reference materials using different commercially available ACPA assays. MATERIALS AND METHODS: This is an international study in which the NIBSC candidate ACPA standard and the IUIS-CDC ACPA reference material were analysed together with 398 diagnostic samples from individuals with rheumatoid arthritis (RA) and in 1073 individuals who did not have RA using nine commercial ACPA assays. RESULTS: For both reference materials and samples from individuals with RA and individuals who did not have RA, there were large differences in quantitative ACPA results between assays. For most assays, values for the IUIS-CDC standard were lower than values for NIBSC 18/204 and the IUIS-CDC/NIBSC ratio was comparable for several, but not all assays. When NIBSC 18/204 was used as a calibrator, an improvement in alignment of ACPA results across several of the evaluated assays was obtained. Moreover, NIBSC 18/204 could align clinical interpretation for some but not all assays. CONCLUSION: Adoption of an international standard for ACPA determination is highly desirable. The candidate NIBSC 18/204 standard improved the standardisation and alignment of most ACPA assays and might therefore be recommended to be used as reference in commercial assays.

6.
Clin Chem Lab Med ; 60(9): 1373-1383, 2022 08 26.
Artículo en Inglés | MEDLINE | ID: mdl-35749077

RESUMEN

OBJECTIVES: No reference data are available on repositories to measure precision of autoantibody assays. The scope of this study was to document inter- and intra-run variations of quantitative autoantibody assays based on a real-world large international data set. METHODS: Members of the European Autoimmunity Standardisation Initiative (EASI) group collected the data of intra- and inter-run variability obtained with assays quantifying 15 different autoantibodies in voluntary participating laboratories from their country. We analyzed the impact on the assay performances of the type of immunoassay, the number of measurements used to calculate the coefficient of variation (CVs), the nature and the autoantibody level of the internal quality control (IQC). RESULTS: Data were obtained from 64 laboratories from 15 European countries between February and October 2021. We analyzed 686 and 1,331 values of intra- and inter-run CVs, respectively. Both CVs were significantly dependent on: the method of immunoassay, the level of IQC with higher imprecision observed when the antibody levels were lower than 2-fold the threshold for positivity, and the nature of the IQC with commercial IQCs having lower CVs than patients-derived IQCs. Our analyses also show that the type of autoantibody has low impact on the assay' performances and that 15 measurements are sufficient to establish reliable intra- and inter-run variations. CONCLUSIONS: This study provides for the first time an international repository yielding values of intra- and inter-run variation for quantitative autoantibody assays. These data could be useful for ISO 15189 accreditation requirements and will allow clinical diagnostic laboratories to assure quality of patient results.


Asunto(s)
Autoanticuerpos , Servicios de Laboratorio Clínico , Humanos , Laboratorios , Control de Calidad , Estándares de Referencia
7.
Clin Chem Lab Med ; 60(10): 1617-1626, 2022 09 27.
Artículo en Inglés | MEDLINE | ID: mdl-35790193

RESUMEN

OBJECTIVES: Rheumatoid factor (RF) is a well-established marker for the diagnosis and classification of rheumatoid arthritis (RA). Most studies evaluated IgM RF or isotype-nonspecific total RF assays. We evaluated the added value of IgA RF in this context. METHODS: An international sample cohort consisting of samples from 398 RA patients and 1073 controls was tested for IgA RF with 3 commercial assays. For all RA patients and 100 controls essential clinical and serological data for ACR/EULAR classification were available. RESULTS: The sensitivity of IgA RF for diagnosing RA was lower than the sensitivity of IgM RF. Differences in numerical values between IgA RF assays were observed. With all assays, the highest IgA RF values were found in patients with primary Sjögren's syndrome. Double positivity for IgM RF and IgA RF had a higher specificity for RA than either IgM RF or IgA RF. The sensitivity of double positivity was lower than the sensitivity of either IgA RF or IgM RF. Single positivity for IgA RF was at least as prevalent in controls than in RA patients. Adding IgA RF to IgM RF and anti-citrullinated protein antibodies (ACPA) did not affect RA classification. However, combined positivity for IgA RF, IgM RF and IgG ACPA had a higher specificity and lower sensitivity for RA classification than positivity for either of the antibodies. CONCLUSIONS: IgA RF showed a lower sensitivity than IgM RF. Combining IgA RF with IgM RF and ACPA did not improve sensitivity of RA classification. Combined positivity (IgA-RF/IgM-RF/ACPA) increased specificity.


Asunto(s)
Artritis Reumatoide , Inmunoglobulina A , Inmunoglobulina M , Factor Reumatoide , Artritis Reumatoide/diagnóstico , Humanos , Inmunoglobulina A/química , Inmunoglobulina M/química , Péptidos Cíclicos , Factor Reumatoide/metabolismo , Sensibilidad y Especificidad
8.
J Pediatr Gastroenterol Nutr ; 72(5): 661-666, 2021 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-32810036

RESUMEN

OBJECTIVES: Autoantibodies (AAb) and donor-specific HLA antibodies (DSA) are frequently present in pediatric liver transplant (LT) recipients. Their clinical significance remains incompletely understood. We aimed to investigate the prevalence of serum AAb and DSA in pediatric LT recipients and its correlation with patient characteristics and histological and biochemical parameters. METHODS: We retrospectively reviewed the data from 62 pediatric LT patients in follow-up at Ghent University Hospital between January 2007 and February 2018. Blood samples with AAb measurement were taken systematically, liver biopsies (LB) were performed on clinical indication. RESULTS: AAb were detected in 27 (43.3%) patients, with antinuclear antibodies (ANA) being the most frequently (24%) encountered AAb. There was an association between AAb positivity and female gender (P = 0,032) and deceased donor LT (P = 0,006). Patients with positive AAb underwent a higher number of LB during their follow-up (P < 0,001), and an association was found with the presence of nonspecific histologic alterations (P = 0,032) in the absence of de novo autoimmune hepatitis. Positive AAb were also associated with higher alkaline phosphatase (P < 0,001), ALT (P < 0,001), AST (P < 0,001), γ-GT (P = 0,001), IgG (P = 0,011) and lower albumin (P = 0,029). Fourteen out of 50 (28%) patients were DSA-positive, mostly anti-HLA class II. DSA positivity was associated with T-cell-mediated rejection (P = 0,019), higher total (P = 0,033), and direct (P = 0,012) bilirubin and γ-GT (P < 0,001). CONCLUSIONS: The presence of AAb and DSA is associated with histological and biochemical parameters of graft dysfunction. Larger prospective studies are warranted to investigate the causal relationships between AAb and DSA development and outcome parameters post pediatric LT.


Asunto(s)
Trasplante de Hígado , Autoanticuerpos , Niño , Femenino , Rechazo de Injerto , Supervivencia de Injerto , Antígenos HLA , Humanos , Isoanticuerpos , Estudios Prospectivos , Estudios Retrospectivos
9.
Clin Exp Rheumatol ; 38(2): 212-219, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31287411

RESUMEN

OBJECTIVES: Today, the contribution of myositis-specific autoantibodies (MSA) in the diagnostic workup of idiopathic inflammatory myopathies (IIM) is on the rise. The aim of this study was to document MSA frequency as detected by lineblot in a set of consecutive MSA requests and to correlate the results with clinical diagnosis, IIM subtype and indirect immunofluorescence (IIF) findings. Additionally, a comparison between two lineblots was performed. METHODS: A total of 118 consecutive samples of patients with suspicion of IIM were analysed on IIF and two lineblots. A total of 107 patients with autoimmune rheumatic diseases served as controls. RESULTS: MSA were detected in 55% of IIM patients (n=31) and 7.9% (n=12) of patients without clinical diagnosis of IIM or myositis overlap syndrome. All the IIM patients had a MSA-compatible clinical subtype. There was no to fair agreement between both lineblots for the individual antibodies, with most discrepancies observed for anti-TIF1γ (κ=-0.021), anti-SRP (κ=-0.006) and anti-SAE (κ=0.395). Differences between both assays were mostly observed in the non-IIM patients, also showing signi cantly lower blot signal intensities compared to IIM patients (p=0.0013). MSA in the non-IIM patients frequently showed an incompatible IIF pattern. CONCLUSIONS: Lineblot seems to be an interesting tool for MSA detection in a clinical context, allowing the identification of clinical subtypes. However, considerable caution must be exercised in interpreting the results in case of low positive MSA signal intensity, discordant lineblot results and/or an incompatible IIF pattern.


Asunto(s)
Autoanticuerpos/inmunología , Miositis/diagnóstico , Miositis/inmunología , Autoanticuerpos/sangre , Enfermedades Autoinmunes , Técnica del Anticuerpo Fluorescente Indirecta , Humanos , Síndrome
10.
Clin Chem Lab Med ; 58(3): 416-423, 2020 02 25.
Artículo en Inglés | MEDLINE | ID: mdl-31714880

RESUMEN

Background Systemic sclerosis (SSc) and primary biliary cholangitis (PBC) are autoimmune diseases that may occur concomitantly and are both strongly associated with disease-specific autoantibodies. This study investigated the prevalence and fine specificity of PBC-specific serology (PBC-Ab) and associations with the SSc-subtypes and SSc-specific antibodies as well as the association with cholestatic liver enzymes. Furthermore, three different techniques for the detection of PBC-Ab were compared. Methods Serum of 184 Belgian SSc patients with a known SSc-antibody profile, was analyzed for PBC-Ab (antimitochondrial antibodies [AMA], anti-Gp210, anti-Sp100 and anti-PML) using indirect immunofluorescence (IIF) analysis on human epithelioma-2000 (HEp-2000) cells (ANA-IIF, Immunoconcepts) and liver-kidney-stomach tissue sections (IIF-LKS) (Menarini), and a line immunoblot (LB) (EuroImmun). Alkaline phosphatase/γ-glutamyl transferase (ALP/GGT) were evaluated at time of first sampling (t0) and after 3 years of follow-up (t3). Results PBC-Ab were present in 13% of patients and significantly correlated with centromere antibodies (anti-CENP-B), but not correlated with the limited cutaneous SSc subgroup (lcSSc). The most frequent reactivities were AMA (11%, with 9% AMA-M2) and Sp-100 antibodies (5%), showing a major overlap. There was no relevant association between the presence of PBC-Ab and ALP or GGT elevation at t0 nor at t3. Detection of AMA with IIF-LKS is comparable to LB. ANA-IIF screening was less sensitive compared to LB. Conclusions A wide range of PBC-Ab is detectable in SSc in the absence of cholestatic liver enzyme elevations, even after 3 years of follow-up. However, as these antibodies may precede PBC-disease up to 10 years further prospective follow-up of our cohort will be necessary.


Asunto(s)
Cirrosis Hepática Biliar/complicaciones , Cirrosis Hepática Biliar/inmunología , Esclerodermia Sistémica/complicaciones , Pruebas Serológicas , Adulto , Bélgica , Estudios de Cohortes , Femenino , Humanos , Cirrosis Hepática Biliar/diagnóstico , Masculino , Persona de Mediana Edad
11.
J Allergy Clin Immunol ; 144(3): 809-824, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-30826363

RESUMEN

BACKGROUND: Predominantly antibody deficiencies (PADs) are the most prevalent primary immunodeficiencies, but their B-cell defects and underlying genetic alterations remain largely unknown. OBJECTIVE: We investigated patients with PADs for the distribution of 41 blood B-cell and plasma cell (PC) subsets, including subsets defined by expression of distinct immunoglobulin heavy chain subclasses. METHODS: Blood samples from 139 patients with PADs, 61 patients with common variable immunodeficiency (CVID), 68 patients with selective IgA deficiency (IgAdef), 10 patients with IgG subclass deficiency with IgA deficiency, and 223 age-matched control subjects were studied by using flow cytometry with EuroFlow immunoglobulin isotype staining. Patients were classified according to their B-cell and PC immune profile, and the obtained patient clusters were correlated with clinical manifestations of PADs. RESULTS: Decreased counts of blood PCs, memory B cells (MBCs), or both expressing distinct IgA and IgG subclasses were identified in all patients with PADs. In patients with IgAdef, B-cell defects were mainly restricted to surface membrane (sm)IgA+ PCs and MBCs, with 2 clear subgroups showing strongly decreased numbers of smIgA+ PCs with mild versus severe smIgA+ MBC defects and higher frequencies of nonrespiratory tract infections, autoimmunity, and affected family members. Patients with IgG subclass deficiency with IgA deficiency and those with CVID showed defects in both smIgA+ and smIgG+ MBCs and PCs. Reduced numbers of switched PCs were systematically found in patients with CVID (absent in 98%), with 6 different defective MBC (and clinical) profiles: (1) profound decrease in MBC numbers; (2) defective CD27+ MBCs with almost normal IgG3+ MBCs; (3) absence of switched MBCs; and (4) presence of both unswitched and switched MBCs without and; (5) with IgG2+ MBCs; and (6) with IgA1+ MBCs. CONCLUSION: Distinct PAD defective B-cell patterns were identified that are associated with unique clinical profiles.


Asunto(s)
Subgrupos de Linfocitos B/inmunología , Síndromes de Inmunodeficiencia/inmunología , Células Plasmáticas/inmunología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Recuento de Células , Niño , Preescolar , Femenino , Humanos , Inmunoglobulinas/deficiencia , Inmunoglobulinas/inmunología , Masculino , Persona de Mediana Edad , Adulto Joven
12.
Clin Chem Lab Med ; 56(7): 1090-1099, 2018 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-29427547

RESUMEN

BACKGROUND: Screening for antinuclear antibodies by indirect immunofluorescence (ANA-IIF) is essential in the diagnostic workup of ANA-associated autoimmune rheumatic diseases (AARDs). However, also healthy individuals may test positive, making the interpretation challenging. Recent reports suggest that dense fine speckled 70 antibodies (anti-DFS70) may facilitate this challenge. Here, we investigate their clinical importance based on data from four Belgian laboratories (one primary, two secondary and one tertiary care). METHODS: At least one specific DFS70 assay (DFS70 IgG ELISA or lineblot [Euroimmun, full length antigen] and/or DFS70 IgG CLIA [Inova Diagnostics, truncated antigen]) was performed on four consecutive cohorts of homogeneous-like ANA-IIF samples (n=697). Co-occurrence with AARD-specific ANA and clinical information were documented in the anti-DFS70-positive samples. RESULTS: Using a combination of solid phase techniques, we found between 7.6% and 26% anti-DFS70 in the different cohorts. Focusing on anti-DFS70 CLIA-positive samples without co-occurrence of AARD-specific ANA, we observed a trend towards lower frequency in tertiary (8% [p=0.0786]) and secondary care (12% [p=0.1275] and 6% [p<0.001]) compared to primary care (21%). Moreover, in this specific subpopulation, AARD was less frequent (0%-50% compared to 6%-77% in the total anti-DFS70-positive group). CONCLUSIONS: Anti-DFS70 prevalence depends on the applied assay and care setting. Our data suggest that, for an ANA-IIF-positive patient, it is rather the absence of AARD-associated ANA and clinical symptoms that contribute to the exclusion of AARD than the presence of anti-DFS70. Nevertheless, isolated anti-DFS70 helps to clarify positive ANA-IIF results, especially if pretest probability for AARD is low.


Asunto(s)
Proteínas Adaptadoras Transductoras de Señales/inmunología , Anticuerpos Antinucleares/sangre , Enfermedades Autoinmunes/diagnóstico , Enfermedades Reumáticas/diagnóstico , Factores de Transcripción/inmunología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Anticuerpos Antinucleares/inmunología , Bélgica , Femenino , Técnica del Anticuerpo Fluorescente Indirecta/métodos , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
14.
Eur Respir J ; 49(5)2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-28495691

RESUMEN

Screening for pulmonary arterial hypertension (PAH) in systemic sclerosis (SSc) improves outcomes. The DETECT screening algorithm is recommended in a high-risk SSc subgroup. This study aims to compare prospectively the positive predictive value of screening using the DETECT algorithm and the 2009 European Society of Cardiology/European Respiratory Society (ESC/ERS) guidelines, and to compare their cost-effectiveness in an unselected, day-to-day SSc population. Post hoc, screening according to the 2015 ESC/ERS guidelines using echocardiographic parameters alone ("2015 echo screening") or combined with the DETECT algorithm ("2015 combined screening") in high-risk subjects was analysed.195 consecutive SSc patients included in the Ghent University Hospital SSc cohort were screened using different algorithms.The referral rate for right heart catheterisation was 32% (63 out of 195 patients) (46/4/13/34/40 patients using the DETECT algorithm/2009 guidelines/both/2015 echo screening/2015 combined screening). Right heart catheterisation was performed in 53 patients (84%) (36 (78%)/four (100%)/13 (100%)/28 (82%)/32 (80%) patients recommended by the DETECT algorithm/2009 guidelines/both/2015 echo screening/2015 combined screening). PAH was diagnosed in three patients (incidence 1.5%·year-1, 95% CI 0.5-4.4), in whom all algorithms recommended a right heart catheterisation. The positive predictive value was 6% (95% CI 2-17%; three out of 49 patients) for the DETECT algorithm, 18% (95% CI 6-41%; three out of 17 patients) for the 2009 guidelines, 23% (95% CI 8-50%; three out of 13 patients) for both, 11% (95% CI 4-27%; three out of 28 patients) for the 2015 echo screening and 9% (95% CI 3-24%; three out of 32 patients) for the 2015 combined screening. The cost was EUR224/80/90/112 per patient using the DETECT algorithm/2009 guidelines/2015 echo screening/2015 combined screening.Echocardiography may remain a candidate first step for PAH screening in SSc.


Asunto(s)
Hipertensión Pulmonar/diagnóstico , Tamizaje Masivo/métodos , Adulto , Algoritmos , Cateterismo Cardíaco , Análisis Costo-Beneficio , Ecocardiografía , Europa (Continente) , Femenino , Humanos , Hipertensión Pulmonar/complicaciones , Incidencia , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Prevalencia , Estudios Prospectivos , Esclerodermia Sistémica/complicaciones
16.
Haematologica ; 102(1): 192-202, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27634199

RESUMEN

The etiology of primary antibody deficiencies is largely unknown. Beside rare monogenic forms, the majority of cases seem to have a more complex genetic basis. Whereas common variable immunodeficiency has been investigated in depth, there are only a few reports on milder primary antibody deficiencies such as idiopathic primary hypogammaglobulinemia and IgG subclass deficiency. We performed flow cytometric immunophenotyping in 33 patients with common variable immunodeficiency, 23 with idiopathic primary hypogammaglobulinemia and 21 with IgG subclass deficiency, as well as in 47 asymptomatic first-degree family members of patients and 101 unrelated healthy controls. All three groups of patients showed decreased memory B- and naïve T-cell subsets and decreased B-cell activating factor receptor expression. In contrast, circulating follicular helper T-cell frequency and expression of inducible T-cell co-stimulator and chemokine receptors were only significantly altered in patients with common variable immunodeficiency. Asymptomatic first-degree family members of patients demonstrated similar, albeit intermediate, alterations in naïve and memory B- and T-cell subsets. About 13% of asymptomatic relatives had an abnormal peripheral B-cell composition. Furthermore, asymptomatic relatives showed decreased levels of CD4+ recent thymic emigrants and increased central memory T cells. Serum IgG and IgM levels were also significantly lower in asymptomatic relatives than in healthy controls. We conclude that, in our cohort, the immunophenotypic landscape of primary antibody deficiencies comprises a spectrum, in which some alterations are shared between all primary antibody deficiencies whereas others are only associated with common variable immunodeficiency. Importantly, asymptomatic first-degree family members of patients were found to have an intermediate phenotype for peripheral B- and T-cell subsets.


Asunto(s)
Agammaglobulinemia/diagnóstico , Enfermedades Asintomáticas , Inmunodeficiencia Variable Común/diagnóstico , Familia , Deficiencia de IgG/diagnóstico , Inmunofenotipificación , Adolescente , Adulto , Agammaglobulinemia/sangre , Anciano , Anciano de 80 o más Años , Subgrupos de Linfocitos B/inmunología , Subgrupos de Linfocitos B/metabolismo , Biomarcadores , Estudios de Casos y Controles , Niño , Preescolar , Análisis por Conglomerados , Inmunodeficiencia Variable Común/sangre , Células Dendríticas/inmunología , Células Dendríticas/metabolismo , Femenino , Humanos , Deficiencia de IgG/sangre , Inmunoglobulinas/sangre , Inmunofenotipificación/métodos , Masculino , Persona de Mediana Edad , Fenotipo , Subgrupos de Linfocitos T/inmunología , Subgrupos de Linfocitos T/metabolismo , Adulto Joven
19.
Clin Chem Lab Med ; 52(7): 989-98, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24598837

RESUMEN

BACKGROUND: Screening for anti-nuclear antibodies by indirect immunofluorescence (ANA-IIF) remains mandatory in the serological work-up of connective tissue diseases. Recently, automated approaches were introduced that may improve harmonization. Here, we investigated whether the introduction of automated ANA-IIF and more specifically the use of its quantitative measure, could improve ANA-IIF internal quality control (IQC) management. METHODS: We retrospectively reviewed results of two cohorts of routine samples and parallel IQC data collected from January 2010 to February 2013 and from February to mid October 2013. For the first cohort, data were collected using conventional microscopy. The second cohort was analyzed by an automated ANA-IIF microscope (Zenit G sight, A. Menarini). Retrospectively, we evaluated the applicability of the probability index (PI) of control material measurements and patient results for IQC management based on Westgard multirules. This approach was also compared with monthly monitoring of the %ANA-IIF positive samples. RESULTS: In our historical data set, we showed that monitoring of %ANA positives identified systematic errors that were not detected by monitoring control material results. Data resulting from automated microscopy showed that PI measurements on control material remained stable within the observed period and that Westgard multirules can be used for IQC follow-up. Parallel monitoring of the daily median patient PI and the monthly %ANA positives, showed that the daily median was a sensitive and fast tool for detecting systematic errors. CONCLUSIONS: The introduction of the automated ANA-IIF microscope could enable objective IQC procedures and should be considered an important step forward in ANA-IIF harmonization.


Asunto(s)
Anticuerpos Antinucleares/análisis , Técnica del Anticuerpo Fluorescente Indirecta , Microscopía Fluorescente , Automatización , Humanos , Control de Calidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA