Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Doc Ophthalmol ; 142(2): 197-211, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-32968834

RESUMEN

PURPOSE: An orientation-specific visual evoked potential (osVEP) protocol was developed to probe meridional anisotropies in children with refractive amblyopia. The aim was to characterise the osVEP response in children with bilateral refractive amblyopia, evaluate the intra-session repeatability of the main osVEP components (C1, C2 and C3), coefficient of repeatability (CoR) of the response to gratings in different meridians and determine if refractive amblyopes have poorer repeatability as compared with non-amblyopic controls. METHODS: Children aged 4-7 years with newly diagnosed and untreated bilateral refractive amblyopia and non-amblyopic controls were recruited. Orientation-specific pattern-onset VEPs were recorded in response to an achromatic sinewave grating stimulus of 4 cycles per degree under monocular and binocular stimulation. The grating lines used for monocular stimulation were parallel with the subjects' most positive and negative astigmatic meridians when considered in sphero-minus cylinder form (Meridians 1 and 2, respectively). In subjects without astigmatism, meridians 1 and 2 were designated horizontal and vertical gratings, respectively. Binocular stimuli were presented with grating lines parallel to meridians 45, 90, 135 and 180°. The repeatability of latencies of the main osVEP components (C1, C2 and C3) were investigated using two successive osVEPs recordings for each stimulus meridian and the CoR for each component's latencies were assessed. RESULTS: Seven amblyopic children (Visual acuity (VA) ranging from 0.08 to 0.40 LogMAR in the less amblyopic eye and 0.26-0.52 LogMAR in the more amblyopic eye) and 7 non-amblyopic controls (VA ranging from 0.00 to 0.02 LogMAR in either eye), with a median age of 4.6 and 7.0 years, respectively, completed the study. C1 had the highest CoR for most conditions assessed. Ratio of CoRs C1:C2 was > 2 for all binocular meridians in controls and the 90 and 180 meridians in the amblyopes; C1:C3 was > 2 for the binocularly assessed 45, 90 and 135 meridians in the controls and the 90 and 180 meridians in the amblyopes; C2:C3 were all < 2 for all meridians assessed in both groups. CONCLUSIONS: The osVEP waveforms are reliable and useful for future investigations into the meridional anisotropies in children with refractive amblyopia, particularly the C3 component. Component C1 had the poorest repeatability, which consequentially affected C2 amplitude estimation. Only C3 amplitude and latency could be consistently estimated as C2 and C3 latencies were similarly repeatable. Coefficients of repeatability of osVEP latencies did not appear to systematically differ between non-amblyopic and amblyopic children.


Asunto(s)
Ambliopía , Potenciales Evocados Visuales , Niño , Preescolar , Electrorretinografía , Humanos , Factores de Tiempo , Agudeza Visual
2.
Gerontol Geriatr Educ ; 42(3): 399-422, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33252017

RESUMEN

Appropriately skilled staff are required to meet the health and care needs of aging populations yet, shared competencies for the workforce are lacking. This study aimed to develop multidisciplinary core competencies for health and aged care workers in Australia through a scoping review and Delphi survey. The scoping review identified 28 records which were synthesized through thematic analysis into draft domains and measurable competencies. Consensus was sought from experts over two Delphi rounds (n = 111 invited; n = 59 round one; n = 42 round two). Ten domains with 66 core competencies, to be interpreted and applied according to the worker's scope of practice were finalized. Consensus on multidisciplinary core competencies which are inclusive of a broad range of registered health professionals and unregistered aged care workers was achieved. Shared knowledge, attitudes, and skills across the workforce may improve the standard and coordination of person-centered, integrated care for older Australians from diverse backgrounds.


Asunto(s)
Geriatría , Anciano , Envejecimiento , Australia , Competencia Clínica , Técnica Delphi , Geriatría/educación , Humanos , Recursos Humanos
3.
J Opt Soc Am A Opt Image Sci Vis ; 37(4): A122-A132, 2020 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-32400532

RESUMEN

Lighting conditions nominated for color vision testing are many and varied. The recommendation of CIE color rendering index (CIE CRI) ≥90 and correlated color temperature of close to 6500 K is widely made for color vision testing generally. With the demise of incandescent and fluorescent lighting and their replacement by light-emitting diodes (LEDs), this is an opportune time to revisit the recommendation. In this paper, we consider the current sources, acceptable and unacceptable, and improvements to the recommendation as it applies to the Farnsworth-Munsell 100 Hue Test (FM100Hue Test). We conclude that there is no need to treat LEDs as a special case but propose a modified CRI measure.

4.
Behav Res Methods ; 50(2): 673-683, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-28411334

RESUMEN

Tablet computer displays are amenable for the development of vision tests in a portable form. Assessing color vision using an easily accessible and portable test may help in the self-monitoring of vision-related changes in ocular/systemic conditions and assist in the early detection of disease processes. Tablet computer-based games were developed with different levels of gamification as a more portable option to assess chromatic contrast sensitivity. Game 1 was designed as a clinical version with no gaming elements. Game 2 was a gamified version of game 1 (added fun elements: feedback, scores, and sounds) and game 3 was a complete game with vision task nested within. The current study aimed to determine the normative values and evaluate repeatability of the tablet computer-based games in comparison with an established test, the Cambridge Colour Test (CCT) Trivector test. Normally sighted individuals [N = 100, median (range) age 19.0 years (18-56 years)] had their chromatic contrast sensitivity evaluated binocularly using the three games and the CCT. Games 1 and 2 and the CCT showed similar absolute thresholds and tolerance intervals, and game 3 had significantly lower values than games 1, 2, and the CCT, due to visual task differences. With the exception of game 3 for blue-yellow, the CCT and tablet computer-based games showed similar repeatability with comparable 95% limits of agreement. The custom-designed games are portable, rapid, and may find application in routine clinical practice, especially for testing younger populations.


Asunto(s)
Defectos de la Visión Cromática/diagnóstico , Visión de Colores/fisiología , Computadoras de Mano , Sensibilidad de Contraste/fisiología , Programas Informáticos , Juegos de Video , Pruebas de Visión/instrumentación , Adolescente , Adulto , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Adulto Joven
5.
Behav Res Methods ; 49(2): 548-558, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-27004485

RESUMEN

Recent advances in technology and the increased use of tablet computers for mobile health applications such as vision testing necessitate an understanding of the behavior of the displays of such devices, to facilitate the reproduction of existing or the development of new vision assessment tests. The purpose of this study was to investigate the physical characteristics of one model of tablet computer (iPad mini Retina display) with regard to display consistency across a set of devices (15) and their potential application as clinical vision assessment tools. Once the tablet computer was switched on, it required about 13 min to reach luminance stability, while chromaticity remained constant. The luminance output of the device remained stable until a battery level of 5%. Luminance varied from center to peripheral locations of the display and with viewing angle, whereas the chromaticity did not vary. A minimal (1%) variation in luminance was observed due to temperature, and once again chromaticity remained constant. Also, these devices showed good temporal stability of luminance and chromaticity. All 15 tablet computers showed gamma functions approximating the standard gamma (2.20) and showed similar color gamut sizes, except for the blue primary, which displayed minimal variations. The physical characteristics across the 15 devices were similar and are known, thereby facilitating the use of this model of tablet computer as visual stimulus displays.


Asunto(s)
Computadoras de Mano/normas , Pruebas de Visión/instrumentación , Pruebas de Visión/métodos , Visión Ocular/fisiología , Color/normas , Humanos , Estimulación Luminosa
6.
Optom Vis Sci ; 92(10): 995-1002, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26367341

RESUMEN

PURPOSE: It is widely known that visual impairment (VI) is a risk factor for falls, but patients or their eye care practitioners may not recognize other kinds of incidents as being problematic because of their vision. Consequently, older people with VI may have unmet needs for advice on how to carry out activities of daily living safely. Therefore, the purpose of this study was to understand whether older people with VI consider their vision as a causative factor of incidents they experience and their perceptions regarding the prevention of future incidents. If sample size permitted, a secondary aim was to evaluate whether quantitative findings supported their perceptions. METHODS: The study design was a prospective cohort study evaluating injurious and damaging incidents and related near misses using open questions in a written 2-weekly large-print diary with active follow-up over 8 weeks in older people (>60 years, n = 80) with and without VI. Baseline measures included habitual binocular visual acuity, contrast sensitivity, visual fields, 3-m walk test, and Short Form 12 physical and mental component scores. Participants' diary entries were coded. Factor analysis and binary logistic analysis were used to investigate whether baseline measures were predictive of incident occurrence. Risk and preventative factors identified were compared. RESULTS: Participants perceived that their vision was implicated in bump and fall incidents. Quantitative analysis indicated that contrast sensitivity and fitness were significant predictors of incident occurrence. Six vision-related and five non-vision-related causative factors were identified by participants as contributing factors. Participants frequently stated "don't know" when asked to identify solutions to prevent incident recurrence. CONCLUSIONS: Participants had unmet needs for advice in relation to incident prevention. It would be prudent for eye care practitioners to raise incident prevention in eye care consultations regardless of voiced patient concerns.


Asunto(s)
Accidentes por Caídas , Baja Visión/psicología , Personas con Daño Visual/psicología , Heridas y Lesiones/psicología , Actividades Cotidianas , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Sensibilidad de Contraste/fisiología , Femenino , Evaluación Geriátrica , Necesidades y Demandas de Servicios de Salud , Humanos , Masculino , Estudios Prospectivos , Factores de Riesgo , Agudeza Visual/fisiología , Campos Visuales/fisiología , Heridas y Lesiones/prevención & control
7.
Clin Exp Optom ; : 1-9, 2024 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-38175925

RESUMEN

CLINICAL RELEVANCE: The possibility that changes in blue-yellow visual thresholds and some retinal thickness measures in children with diabetes mellitus may be observed before any visible fundus changes points to the possibility of these measures being a useful predictor that the risks of diabetic retinopathy are higher in some children than in others. INTRODUCTION: Previous studies showed mixed results on chromatic and achromatic contrast sensitivity early in the course of diabetes mellitus, and the findings of these studies may have been influenced by a lack of experimental sensitivity to visual deficits, a bias towards tritan-like errors or the cognitive demands of the tests and variations in sample composition. The purpose of this study was to evaluate colour and contrast thresholds and retinal thickness in children with type 1 diabetes mellitus compared with age-matched controls. METHODS: A prospective case-control study was carried out on 9-14-year-old children with type 1 diabetes mellitus (49 cases) and age matched controls (49) in which isoluminant red-green and blue-yellow and achromatic luminance contrast thresholds were measured. Fundus photography was used to grade diabetic retinopathy. Retinal thickness parameters were measured using optical coherence tomography. Data on the duration of diabetes mellitus, glycaemic control (HbA1c), blood glucose level, body mass index, blood pressure and blood oxygenation at the time of testing were obtained. RESULTS: The cases mostly had poorly controlled diabetes, HbA1c 8.6% (6.4-12.8%), for an average (range) duration of 5 (0.4-12) years. The cases had significantly higher blue-yellow thresholds (p = 0.02) and greater total retinal and inner retinal thickness (p < 0.05) than controls. No cases had diabetic retinopathy. Within the cases, poorer visual function and systemic health measures were associated with thinner retinal structures and greater global loss volume percentage in the ganglion cell complex. CONCLUSION: Blue-yellow thresholds of cases were raised compared to normal. Within the cases, higher luminance contrast thresholds were also associated with, mostly, ganglion cell complex reductions.

8.
Vision Res ; 222: 108439, 2024 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-38896923

RESUMEN

It is important to understand the development of meridional anisotropies in neurotypical children since those with poor visual development, such as amblyopia, can have different patterns of meridional anisotropies. While the oblique effect is usually observed in adults, neurotypical children who have normal 20/20 visual acuity tend to demonstrate a horizontal effect electrophysiologically. In this longitudinal study, orientation-specific visual evoked potentials (osVEPs) and psychophysical grating acuity were used to investigate the changes in the meridional anisotropies in children aged 3.8 to 9.2 years over two visits averaging four months apart. While it was hypothesized that the electrophysiological horizontal effect may shift towards an oblique effect, it was found that the electrophysiological horizontal effect persisted to be present in response to the suprathreshold moderate contrast 4 cycles-per-degree grating stimuli. Psychophysical grating acuity, however, demonstrated an oblique effect when assessed binocularly. In addition, a significant effect of visit, representing an increase in the average age over this period, was observed in the average osVEP C3 amplitudes (4.5 µV) and psychophysical grating acuity (0.28 octaves or approximately 1-line on the logMAR chart). These findings are relevant when evaluating amblyopia treatments and interventions, as it confirms the necessity to take into account of the effect of normal maturation and learning effects when evaluating young children. Special attention should also be given to children with early-onset myopia and high astigmatism even when their visual acuity is 20/20 as the electrophysiological findings are suggestive of poor visual development, which warrants further investigation.

9.
Clin Exp Optom ; 106(2): 110-118, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36336833

RESUMEN

Access to culturally safe health services is a basic human right, however through the lasting effects of colonisation, oppression, and systemic racism, the individual and community health of Indigenous peoples in Australia and Aotearoa New Zealand have been severely impacted. The Aboriginal and Torres Strait Islander Health and Cultural Safety Strategy of the Australian Health Practitioners Regulation Agency, and the Standards of Cultural Competence and Cultural Safety of the Optometrists and Dispensing Opticians Board of New Zealand, recognise the importance of access to safe health care for Aboriginal, Torres Strait Islander and Maori patients, which encompasses both clinical competency and cultural safety. Universities have an ongoing responsibility to ensure their learning and teaching activities result in graduates being able to provide culturally safe practice. This article highlights the emergence of culturally safe practices in the Australian and Aotearoa New Zealand optometry curricula over the last five years incorporating Indigenous ways of knowing, being and doing into the curricula, understanding the local Indigenous histories and contexts, the adoption of online cultural education modules, and clinical placement partnerships with local Indigenous communities. Whilst there is still much work to do to achieve the goal of graduating culturally safe optometrists, this paper focuses on features that enable or impede progress in the development of culturally safe practices within the optometry programmes to improve eye health equity for Indigenous recognise the diversity of Indigenous cultures across Australia and NZ.


Asunto(s)
Servicios de Salud del Indígena , Optometría , Humanos , Australia , Optometría/educación , Nueva Zelanda , Atención a la Salud , Competencia Cultural/educación , Instituciones Académicas
10.
Clin Exp Optom ; 105(6): 642-648, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-34402764

RESUMEN

Patients should be able to rely on optometrists and optical dispensers to provide evidence-based answers to their questions on eye protection, including against ultraviolet radiation. Surveys indicate that there is public concern about the need for protection against ultraviolet radiation, particularly in sunlight. This investigation aimed to evaluate the quality of information provided by practitioners in response to typical questions to which they might reasonably be expected to have ready answers. A cross-sectional study was conducted of on-site responses from attendees of a 3 day optical fair, in Sydney, Australia, in 2017. Subjects were not forewarned about the study. The portion of the questionnaire reported here comprised open answers to four questions intended to represent typical enquiries of patients. The questions were about recommendations for ultraviolet protection in the context of 1) computer use, 2) outdoor use, 3) driving and 4) under office lighting. Eighty-three participants returned completed questionnaires out of 140 issued (61% response). The open-answer question responses were grouped into appropriate, borderline (mostly appropriate but mixed with non-UVR related recommendations) and others (mostly non-UVR related recommendations) and by job title. The proportion of appropriate answers to the four questions were 20%, 30%, 12% and 15%, respectively, which did not differ by job title. A significantly higher proportion of optical dispensers than optometrists selected 'Don't know/no answer' for all questions except office use. Eyecare professionals need to be educated on eye protection against UV radiation to improve the quality of information to be given to the public.


Asunto(s)
Luz Solar , Rayos Ultravioleta , Australia , Estudios Transversales , Humanos , Rayos Ultravioleta/efectos adversos
11.
Work ; 73(4): 1265-1278, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36093666

RESUMEN

BACKGROUND: Standards for building elements recommend a minimum luminance contrast of 30%. The basis of this value and the metric originally used is not known. OBJECTIVE: To begin to provide an evidence base for the specification of minimum contrast in building elements. METHODS: Subjects with and without a vision impairment were characterized by visual acuity, contrast sensitivity, visual fields and color vision. On an iPad they rated the visibility, as a function of contrast, of simulated door frames, door handles, light switches and stair nosings as "not visible at all", "poorly visible", "easily visible" and "extremely easily visible". RESULTS: The contrasts for each level of visibility were highly correlated with visual acuity and contrast sensitivity. A principal component analysis also verified the importance of visual acuity, contrast sensitivity and visual fields in rating visibility of simulations of building elements. The required contrast for door handles, light switches and stair nosings to attain the same ratings of visibility were very similar but less contrast was required for door frames. CONCLUSIONS: 30% Michelson contrast for building elements renders building elements only poorly visible for those with severe vision impairments. 65% luminance contrast is necessary for all elements to be "easily visible". Some increase (not a decrease) on the present 30% requirement and encouragement to exceed this requirement would seem appropriate. The use of simulated objects facilitates a systematic examination of the effect of contrast, but the applicability of the results to real-life remains to be demonstrated.


Asunto(s)
Sensibilidad de Contraste , Visión Ocular , Humanos , Agudeza Visual , Trastornos de la Visión , Entorno Construido
12.
Doc Ophthalmol ; 122(2): 99-113, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21369862

RESUMEN

Transient chromatic pattern visual evoked potentials (VEPs) have been found to be less repeatable in morphology in children than in adults at low to moderate chromatic contrasts. The purpose of this study is to investigate whether low repeatability of VEP components can be associated with high alpha power, in a comparison of alpha activity in children and adults. Transient chromatic contrast and achromatic resolution VEPs were recorded in children (n = 14, mean 9.6 years) and adults (n = 12, mean 21.8 years) with normal vision and assessed for repeatability. Isoluminant chromatic (magenta-cyan) and luminance-modulated achromatic grating stimuli were presented at and above psychophysical threshold levels, in pattern onset-offset at 2 Hz temporal frequency. EEGs (eyes closed and open) were recorded as single sweeps (1 s long) over three 30 s periods while facing a uniform computer display. An index of VEP detectability by observation was developed based on VEP component repeatability. The index was examined for correlations with alpha-wave parameters. Alpha power was calculated as the sum of the powers of 8-13 Hz frequencies of the EEG sweeps (using the discrete Fourier transform). Alpha power variability was calculated using the standard deviation of the powers of each sweep in a 30 s time period. The children had significantly higher alpha powers than the adults for both the eyes-open and eyes-closed conditions. Alpha power variability was significantly higher for the eyes-open condition only. There was no relationship between alpha power parameters and index of VEP detectability by observation for both the chromatic and achromatic grating stimuli. Poor repeatability of transient pattern VEPs is not associated with high alpha power or its variability in EEG measurements in older children or young adults at Oz.


Asunto(s)
Ritmo alfa/fisiología , Percepción de Color/fisiología , Electroencefalografía , Potenciales Evocados Visuales/fisiología , Reconocimiento Visual de Modelos/fisiología , Adolescente , Adulto , Niño , Femenino , Humanos , Masculino , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Adulto Joven
13.
Clin Exp Optom ; 104(1): 56-61, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33090580

RESUMEN

CLINICAL RELEVANCE: Tinted lenses may adversely affect colour discrimination. Before recommending tinted lenses to patients, practitioners should bear in mind any effects on colour discrimination. The effects of 'blue-blocking' spectacle lenses with high luminous transmittance on colour vision is not a concern. BACKGROUND: Blue-blocking lenses have been widely promoted by manufacturers and practitioners. The more blue-blocking lenses are known to affect colour vision significantly but there has been no study of the effects of 'blue-blocking' spectacle lenses. METHODS: The transmittances of commercially available lenses were measured and the three lenses with the lowest blue light transmittance were selected. Subjects undertook the following computer-based colour vision tests: Colour Assessment and Diagnosis; the Cambridge Colour Test; and the Farnsworth-Munsell 100 Hue Test. RESULTS: Blue and luminous transmittances of lenses were documented. The reduction in blue transmittance varied from 12 to 40 per cent (two to 30 per cent compared with an untinted lens). The lenses were found to have no significant, statistical or possibly practical, effect on the results of the three colour vision tests (t-test, analysis of variance, Mann-Whitney, Kruskal-Wallis). CONCLUSION: The modest blue light transmittance reduction of the 'blue-blocking' spectacle lenses examined was not sufficient to have a statistically significant effect on colour vision.


Asunto(s)
Visión de Colores , Cristalino , Lentes Intraoculares , Color , Percepción de Color , Humanos
14.
Work ; 70(4): 1219-1227, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34842207

RESUMEN

BACKGROUND: Standards writers, national and international, have used different contrast calculations to set requirements in building elements for people with visual impairments. On the other hand, they have typically set a single requirement (30%) for specifying the minimum contrast. The systems are not linearly related and 30% means something rather different in each system. OBJECTIVE: To provide a comparison of the various scales in order to illustrate the differences caused by multiple scales with a single compliance value, recommend a single scale for universal adoption and, if a new measure is problematic for implementation, to recommend the most perceptually uniform of the present methods. METHODS: We use the contrast between combinations of 205 paint colours to illustrate the relationships between the measures. We use an internationally accepted scale, with equal perceptual steps, as a "gold standard" to identify the most perceptually uniform measurement scale in the existing methods. RESULTS: We show that Michelson contrast is the most perceptually uniform of the existing measurement scales. We show the contrasts in the proposed method that equate to the various current requirements. CONCLUSIONS: We propose that CIE Metric Lightness could be used as the contrast measure. Alternatively, Michelson contrast is the most perceptually linear of the current measurement scales.


Asunto(s)
Personas con Discapacidad , Humanos , Proyectos de Investigación
15.
Clin Exp Optom ; 103(6): 870-876, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32201990

RESUMEN

BACKGROUND: Convergence insufficiency may be treated by visual exercises designed to increase convergence while maintaining single, clear, binocular vision. However, compliance with treatment is problematic, as patients often cease treatment when symptoms start to improve and before treatment is complete. The purpose of the present study was to assess the feasibility of using gamification of vision training to: (a) treat convergence insufficiency; and (b) improve compliance to treatment in comparison to a conventional treatment over a six-week treatment period. METHODS: Two interventions, anaglyphs and a virtual reality game of Snakes, were evaluated for their effectiveness in treating adults with convergence insufficiency. The prescribed training regimen was 20 minutes, three times per week for six weeks. Vision was assessed before and after the treatment period. Participants also filled in the Core Elements of the Gaming Experience Questionnaire to gauge impact of game design on compliance. RESULTS: Eighteen participants (mean age 20.8 ± 1.8 years) met the inclusion criteria for convergence insufficiency and nine participants were randomly assigned to each intervention. Repeated measures analysis of variance showed a significant effect of visit for near point of convergence (F1,16 = 38.32, p < 0.0001), near positive fusional reserves break (F1,16 = 21.94, p < 0.0001) and recovery (F1,16 = 26.87, p < 0.0001), but not of intervention type. Total time played was significantly longer for the virtual reality Snake Game than the anaglyph intervention (p < 0.0001), which translated to mean compliance of 82 per cent and 51 per cent respectively. CONCLUSION: Gamification of vision training in a virtual reality environment is feasible and associated with increased compliance, hence may be a useful strategy to treat convergence insufficiency.


Asunto(s)
Trastornos de la Motilidad Ocular , Realidad Virtual , Convergencia Ocular , Humanos , Trastornos de la Motilidad Ocular/terapia , Ortóptica , Visión Binocular , Adulto Joven
16.
Invest Ophthalmol Vis Sci ; 61(5): 5, 2020 05 11.
Artículo en Inglés | MEDLINE | ID: mdl-32392311

RESUMEN

Purpose: We investigated and characterized the patterns of meridional anisotropies in newly diagnosed refractive amblyopes using pattern onset-offset visual evoked potentials (POVEPs) and psychophysical grating acuity (GA). Methods: Twenty-five refractive amblyopes were recruited and compared with non-amblyopic controls from our previous study. Monocular POVEPs were recorded in response to sinewave 4 cycles per degree (cpd) grating stimuli oriented along each individual participants' principal astigmatic meridians, which were approximately horizontal (meridian 1) and vertical (meridian 2). Binocular POVEPs in response to the same stimuli, but oriented at 45°, 90°, 135°, and 180°, were recorded. Psychophysical GAs were assessed along the same meridians using a two-alternative non-forced-choice technique. The C3 amplitudes and peak latencies of the POVEPs and GAs were compared across meridians for both groups (refractive amblyopes and controls) using linear mixed models (monocular) and ANOVA (binocular), and post hoc analysis was conducted to determine if meridional anisotropies in this cohort of amblyopes were related to low (≤1.50 diopters [D]), moderate (1.75-2.75 D) and high (≥3.00 D) astigmatism. Results: In the newly diagnosed refractive amblyopes, there were no significant meridional anisotropies across all outcome measures, but the post hoc analysis demonstrated that C3 amplitude was significantly higher in those with low (P = 0.02) and moderate (P = 0.004) astigmatism compared to those with high astigmatism. Refractive amblyopes had poorer GA and C3 amplitudes compared to controls by approximately two lines on the logMAR chart (monocular: P = 0.013; binocular: P = 0.014) and approximately 6 µV (monocular: P = 0.009; binocular: P = 0.027), respectively. Conclusions: Deleterious effects of high astigmatism was evident in newly diagnosed refractive amblyopes, but the neural deficits do not seem to be orientation-specific for the stimulus parameters investigated.


Asunto(s)
Ambliopía/fisiopatología , Potenciales Evocados Visuales/fisiología , Orientación/fisiología , Reconocimiento Visual de Modelos/fisiología , Anisotropía , Astigmatismo/fisiopatología , Estudios de Casos y Controles , Niño , Preescolar , Humanos , Psicofísica
17.
Clin Exp Optom ; 103(4): 434-448, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-31838758

RESUMEN

Despite orientation and mobility (O&M) being a significant factor determining quality of life of people with low vision or blindness, there are no gold standard measures or agreement on how to measure O&M performance. In the first part of this systematic review, an inventory of O&M outcome measures used by recent studies to assess the performance of orientation and/or mobility of adults with vision impairment (low vision and blindness) is presented. A wide variety of O&M outcome measures have been implemented in different fields of study, such as epidemiologic research and interventional studies evaluating training, assistive technology, vision rehabilitation and vision restoration. The most frequent aspect of outcome measures is efficiency such as time, distance, speed and percentage of preferred walking speed, followed by obstacle contacts and avoidance, and dis/orientation and veering. Other less commonly used aspects are target identification, safety and social interaction and self-reported outcome measures. Some studies employ sophisticated equipment to capture and analyse O&M performance in a laboratory setting, while others carry out their assessment in real-world indoor or outdoor environments. In the second part of this review, the appropriateness of implementing the identified outcome measures to assess O&M performance in clinical and functional O&M practice is evaluated. Nearly a half of these outcome measures meet all four criteria of face validity (either clinical or functional), responsiveness, reliability and feasibility and have the potential to be implemented in clinical or functional O&M practice. The findings of this review confirm the complicated and dynamic nature of O&M. Multiple measures are required in any evaluation of O&M performance to facilitate holistic assessment of O&M abilities and limitations of each individual.


Asunto(s)
Orientación , Evaluación de Resultado en la Atención de Salud/métodos , Calidad de Vida , Baja Visión/rehabilitación , Caminata , Humanos , Baja Visión/fisiopatología
18.
J Vis ; 9(6): 22.1-17, 2009 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-19761313

RESUMEN

Measures of chromatic contrast sensitivity in children are lower than those of adults. This may be related to immaturities in signal processing at or near threshold. We have found that children's VEPs in response to low contrast supra-threshold chromatic stimuli are more intra-individually variable than those recorded from adults. Here, we report on linear and nonlinear analyses of chromatic VEPs recorded from children and adults. Two measures of signal-to-noise ratio are similar between the adults and children, suggesting that relatively high noise is unlikely to account for the poor clarity of negative and positive peak components in the children's VEPs. Nonlinear analysis indicates higher complexity of adults' than children's chromatic VEPs, at levels of chromatic contrast around and well above threshold.


Asunto(s)
Envejecimiento/fisiología , Percepción de Color/fisiología , Sensibilidad de Contraste/fisiología , Potenciales Evocados Visuales , Adolescente , Adulto , Niño , Preescolar , Femenino , Humanos , Modelos Lineales , Masculino , Dinámicas no Lineales , Estimulación Luminosa/métodos , Psicofísica , Umbral Sensorial
19.
Invest Ophthalmol Vis Sci ; 60(6): 1906-1913, 2019 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-31042798

RESUMEN

Purpose: We investigated the pattern of meridional anisotropies, if any, for pattern onset-offset visual evoked potential (POVEPs) responses and psychophysical grating acuity (GA) in children with normal letter visual acuity (20/20 or better). Methods: A total of 29 children (aged 3-9 years), nine of whom were astigmatic (AS), were recruited. Orientation-specific monocular POVEPs were recorded in response to sinewave grating stimuli oriented along the subjects' principal AS meridians. Horizontal and vertical gratings were designated Meridians 1 and 2, respectively, for nonastigmatic patients (Non-AS). Binocular POVEPs in response to the same stimuli, but oriented at 45°, 90°, 135°, and 180°, were recorded. Psychophysical GAs were assessed monocularly and binocularly along the same meridians using the same stimuli by a 2-alternative-forced-choice staircase technique. The C3 amplitudes and peak latencies of the POVEP and GAs were compared across meridians using linear mixed models (monocular) and ANOVA (binocular). Results: There were significant meridional anisotropies in monocular C3 amplitudes regardless of astigmatism status (P = 0.001): Meridian 2 (mean ± SE Non-AS, 30.13 ± 2.07 µV; AS, 26.53 ± 2.98 µV) was significantly higher than Meridian 1 (Non-AS, 26.14 ± 1.87 µV; AS, 21.68 ± 2.73 µV; P = 0.019), but no meridional anisotropies were found for GA or C3 latency. Binocular C3 amplitude in response to horizontally oriented stimuli (180°, 29.71 ± 3.06 µV) was significantly lower than the oblique (45°, 36.62 ± 3 .05 µV; P = 0.03 and 135°, 35.95 ± 2.92 µV; P = 0.04) and vertical (90°, 37.82 ± 3.65 µV; P = 0.02) meridians, and binocular C3 latency was significantly shorter in response to vertical than oblique gratings (P ≤ 0.001). Conclusions: Meridional anisotropy was observed in children with normal vision. The findings suggest that horizontal gratings result in a small, but significantly lower POVEP amplitude than for vertical and oblique gratings.


Asunto(s)
Astigmatismo/fisiopatología , Potenciales Evocados Visuales/fisiología , Orientación/fisiología , Reconocimiento Visual de Modelos/fisiología , Psicofísica/métodos , Visión Binocular/fisiología , Agudeza Visual , Anisotropía , Astigmatismo/diagnóstico , Niño , Preescolar , Femenino , Humanos , Masculino
20.
J Vis ; 8(1): 6.1-21, 2008 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-18318609

RESUMEN

Visual evoked potentials (VEPs) may be analyzed by examination of the morphology of their components, such as negative (N) and positive (P) peaks. However, methods that rely on component identification may be unreliable when dealing with responses of complex and variable morphology; therefore, objective methods are also useful. One potentially useful measure of the VEP is the correlation dimension. Its relevance to the visual system was investigated by examining its behavior when applied to the transient VEP in response to a range of chromatic contrasts (42%, two times psychophysical threshold, at psychophysical threshold) and to the visually unevoked response (zero contrast). Tests of nonlinearity (e.g., surrogate testing) were conducted. The correlation dimension was found to be negatively correlated with a stimulus property (chromatic contrast) and a known linear measure (the Fourier-derived VEP amplitude). It was also found to be related to visibility and perception of the stimulus such that the dimension reached a maximum for most of the participants at psychophysical threshold. The latter suggests that the correlation dimension may be useful as a diagnostic parameter to estimate psychophysical threshold and may find application in the objective screening and monitoring of congenital and acquired color vision deficiencies, with or without associated disease processes.


Asunto(s)
Percepción de Color/fisiología , Sensibilidad de Contraste/fisiología , Potenciales Evocados Visuales/fisiología , Percepción Espacial/fisiología , Adulto , Femenino , Análisis de Fourier , Humanos , Masculino , Estimulación Luminosa , Psicofísica , Umbral Sensorial/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA