Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 224
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Circulation ; 148(18): 1371-1380, 2023 10 31.
Artículo en Inglés | MEDLINE | ID: mdl-37772419

RESUMEN

BACKGROUND: Patients with previous coronary artery bypass grafting often require invasive coronary angiography (ICA). However, for these patients, the procedure is technically more challenging and has a higher risk of complications. Observational studies suggest that computed tomography cardiac angiography (CTCA) may facilitate ICA in this group, but this has not been tested in a randomized controlled trial. METHODS: This study was a single-center, open-label randomized controlled trial assessing the benefit of adjunctive CTCA in patients with previous coronary artery bypass grafting referred for ICA. Patients were randomized 1:1 to undergo CTCA before ICA or ICA alone. The co-primary end points were procedural duration of the ICA (defined as the interval between local anesthesia administration for obtaining vascular access and removal of the last catheter), patient satisfaction after ICA using a validated questionnaire, and the incidence of contrast-induced nephropathy. Linear regression was used for procedural duration and patient satisfaction score; contrast-induced nephropathy was analyzed using logistic regression. We applied the Bonferroni correction, with P<0.017 considered significant and 98.33% CIs presented. Secondary end points included incidence of procedural complications and 1-year major adverse cardiac events. RESULTS: Over 3 years, 688 patients were randomized with a median follow-up of 1.0 years. The mean age was 69.8±10.4 years, 108 (15.7%) were women, 402 (58.4%) were White, and there was a high burden of comorbidity (85.3% hypertension and 53.8% diabetes). The median time from coronary artery bypass grafting to angiography was 12.0 years, and there were a median of 3 (interquartile range, 2 to 3) grafts per participant. Procedure duration of the ICA was significantly shorter in the CTCA+ICA group (CTCA+ICA, 18.6±9.5 minutes versus ICA alone, 39.5±16.9 minutes [98.33% CI, -23.5 to -18.4]; P<0.001), alongside improved mean ICA satisfaction scores (1=very good to 5=very poor; -1.1 difference [98.33% CI, -1.2 to -0.9]; P<0.001), and reduced incidence of contrast-induced nephropathy (3.4% versus 27.9%; odds ratio, 0.09 [98.33% CI, 0.04-0.2]; P<0.001). Procedural complications (2.3% versus 10.8%; odds ratio, 0.2 [95% CI, 0.1-0.4]; P<0.001) and 1-year major adverse cardiac events (16.0% versus 29.4%; hazard ratio, 0.4 [95% CI, 0.3-0.6]; P<0.001) were also lower in the CTCA+ICA group. CONCLUSIONS: For patients with previous coronary artery bypass grafting, CTCA before ICA leads to reductions in procedure time and contrast-induced nephropathy, with improved patient satisfaction. CTCA before ICA should be considered in this group of patients. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT03736018.


Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Angiografía Coronaria/efectos adversos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Puente de Arteria Coronaria
2.
Catheter Cardiovasc Interv ; 102(1): 64-70, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37161887

RESUMEN

OBJECTIVES: The study aims to investigate the safety and feasibility of retrograde CTO intervention via collateral connection grade 0 (CC-0) septal channel and to identify predictors of collateral tracking failure. BACKGROUND: Guidewire crossing a collateral channel is a critical step for successful retrograde percutaneous coronary intervention (PCI) of chronic total occlusion (CTO). METHODS: Retrograde PCI was attempted in 122 cases of CTO with CC-0 septal collaterals from December 2018 to May 2021. A hydrophilic polymer coating guidewire was used for crossing all intended CC-0 collaterals. A multivariable logistic regression analysis was performed to identify the predictors of guidewire tracking failure via the CC-0 collaterals. RESULTS: Successful guidewire tracking via CC-0 septal channel was achieved in 98 (80.3%) of 122 cases. The independent predictors of CC-0 septal channel guidewire tracking failure included well-developed non-septal collateral (OR: 5.297, 95% CI: 1.107-25.353, p = 0.037) and the ratio length of posterior descending artery (PDA) versus the distance of PDA ostium to cardiac apex ≤2/3 (OR: 3.970, 95% CI: 1.454-10.835, p = 0.007). Collateral perforation, target vessel perforation, and cardiac tamponade occurred in 5 (4.1%), 3 (2.5%), and 6 (4.9%) cases, respectively. There were no complications requiring emergency cardiac surgery or revascularization of nontarget vessel. CONCLUSIONS: Retrograde PCI via CC-0 septal channels with a hydrophilic polymer-coated guidewire is feasible and safe in patients with CTO. Well-developed nonseptal collaterals and short PDA length influence the procedure success and the risk of guidewire tracking failure via CC-0 septal channels.


Asunto(s)
Oclusión Coronaria , Intervención Coronaria Percutánea , Humanos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Oclusión Coronaria/terapia , Oclusión Coronaria/cirugía , Resultado del Tratamiento , Angiografía Coronaria/métodos , Circulación Colateral , Enfermedad Crónica
3.
Catheter Cardiovasc Interv ; 99(3): 706-713, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34402586

RESUMEN

BACKGROUND: Volumetric intravascular ultrasound (IVUS) analysis is currently performed at a fixed frame interval, neglecting the cyclic changes in vessel dimensions occurring during the cardiac cycle that can affect the reproducibility of the results. Analysis of end-diastolic (ED) IVUS frames has been proposed to overcome this limitation. However, at present, there is lack of data to support its superiority over conventional IVUS. OBJECTIVES: The present study aims to compare the reproducibility of IVUS volumetric analysis performed at a fixed frame interval and at the ED frames, identified retrospectively using a novel deep-learning methodology. METHODS: IVUS data acquired from 97 vessels were included in the present study; each vessel was segmented at 1 mm interval (conventional approach) and at ED frame twice by an expert analyst. Reproducibility was tested for the following metrics; normalized lumen, vessel and total atheroma volume (TAV), and percent atheroma volume (PAV). RESULTS: The mean length of the analyzed segments was 50.0 ± 24.1 mm. ED analysis was more reproducible than the conventional analysis for the normalized lumen (mean difference: 0.76 ± 4.03 mm3 vs. 1.72 ± 11.37 mm3 ; p for the variance of differences ratio < 0.001), vessel (0.30 ± 1.79 mm3 vs. -0.47 ± 10.26 mm3 ; p < 0.001), TAV (-0.46 ± 4.03 mm3 vs. -2.19 ± 14.39 mm3 ; p < 0.001) and PAV (-0.12 ± 0.59% vs. -0.34 ± 1.34%; p < 0.001). Results were similar when the analysis focused on the 10 mm most diseased segment. The superiority of the ED approach was due to a more reproducible detection of the segment of interest and to the fact that it was not susceptible to the longitudinal motion of the IVUS probe and the cyclic changes in vessel dimensions during the cardiac cycle. CONCLUSIONS: ED IVUS segmentation enables more reproducible volumetric analysis and quantification of TAV and PAV that are established end points in longitudinal studies assessing the efficacy of novel pharmacotherapies. Therefore, it should be preferred over conventional IVUS analysis as its higher reproducibility is expected to have an impact on the sample size calculation for the primary end point.


Asunto(s)
Enfermedad de la Arteria Coronaria , Placa Aterosclerótica , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Vasos Coronarios/diagnóstico por imagen , Humanos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Resultado del Tratamiento , Ultrasonografía Intervencional/métodos
4.
Circulation ; 141(16): 1282-1291, 2020 04 21.
Artículo en Inglés | MEDLINE | ID: mdl-32078380

RESUMEN

BACKGROUND: Myocardial perfusion reflects the macro- and microvascular coronary circulation. Recent quantitation developments using cardiovascular magnetic resonance perfusion permit automated measurement clinically. We explored the prognostic significance of stress myocardial blood flow (MBF) and myocardial perfusion reserve (MPR, the ratio of stress to rest MBF). METHODS: A 2-center study of patients with both suspected and known coronary artery disease referred clinically for perfusion assessment. Image analysis was performed automatically using a novel artificial intelligence approach deriving global and regional stress and rest MBF and MPR. Cox proportional hazard models adjusting for comorbidities and cardiovascular magnetic resonance parameters sought associations of stress MBF and MPR with death and major adverse cardiovascular events (MACE), including myocardial infarction, stroke, heart failure hospitalization, late (>90 day) revascularization, and death. RESULTS: A total of 1049 patients were included with a median follow-up of 605 (interquartile range, 464-814) days. There were 42 (4.0%) deaths and 188 MACE in 174 (16.6%) patients. Stress MBF and MPR were independently associated with both death and MACE. For each 1 mL·g-1·min-1 decrease in stress MBF, the adjusted hazard ratios for death and MACE were 1.93 (95% CI, 1.08-3.48, P=0.028) and 2.14 (95% CI, 1.58-2.90, P<0.0001), respectively, even after adjusting for age and comorbidity. For each 1 U decrease in MPR, the adjusted hazard ratios for death and MACE were 2.45 (95% CI, 1.42-4.24, P=0.001) and 1.74 (95% CI, 1.36-2.22, P<0.0001), respectively. In patients without regional perfusion defects on clinical read and no known macrovascular coronary artery disease (n=783), MPR remained independently associated with death and MACE, with stress MBF remaining associated with MACE only. CONCLUSIONS: In patients with known or suspected coronary artery disease, reduced MBF and MPR measured automatically inline using artificial intelligence quantification of cardiovascular magnetic resonance perfusion mapping provides a strong, independent predictor of adverse cardiovascular outcomes.


Asunto(s)
Inteligencia Artificial , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Circulación Coronaria , Angiografía por Resonancia Magnética , Imagen de Perfusión Miocárdica , Anciano , Enfermedad de la Arteria Coronaria/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad
5.
Am Heart J ; 240: 28-45, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34077744

RESUMEN

Advances in image processing and computer hardware have enabled the development of user-friendly software which operate in real-time and can be used in the catheterization laboratory to facilitate percutaneous coronary intervention (PCI). The two dimensional-(2D) quantitative coronary angiography (QCA) systems that have traditionally been used to assess lesion severity have been replaced by 3D-QCA systems, enabling more reliable evaluation of vessel geometry and lesion dimensions. This also allows 3D reconstruction of coronary bifurcation anatomy and generation of models that can be processed by computational fluid dynamic techniques to reliably detect flow-limiting lesions. More recently, software has been introduced that has the capability of generating a digital silhouette of the coronary arteries superimposed onto X-ray angiography to facilitate wire crossing and stent placement, and potentially reduce contrast use. In parallel, methodologies have been developed that operate with an accessible interface and can process intravascular imaging data, reliably quantify lesion severity and co-register intravascular and X-ray angiographic data to comprehensively assess plaque distribution and guide PCI. The above advances are used in daily practice to improve procedural results and outcomes. This review aims to provide an overview of the developments in the field - it presents the computer-based technologies that have been designed to accurately assess lesion severity, summarizes the advantages and limitations of the systems introduced to co-register imaging data and discusses the potential value of the existing and emerging software in the catheterization laboratory.


Asunto(s)
Cateterismo Cardíaco/métodos , Vasos Coronarios/diagnóstico por imagen , Imagenología Tridimensional , Intervención Coronaria Percutánea/métodos , Programas Informáticos , Angiografía Coronaria/métodos , Fluoroscopía/métodos , Humanos , Stents , Tomografía de Coherencia Óptica/métodos , Ultrasonografía Intervencional/métodos
6.
Catheter Cardiovasc Interv ; 98(4): 649-655, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33241605

RESUMEN

OBJECTIVE: We sought to describe the prevalence, management strategies and evaluate the prognosis of patients with iatrogenic catheter-induced ostial coronary artery dissection (ICOCAD). BACKGROUND: ICOCAD is a rare but potentially devastating complication of cardiac catheterisation. The clinical manifestations of ICOCAD vary from asymptomatic angiographic findings to abrupt vessel closure leading to myocardial infarction and death. METHODS: 55,968 patients who underwent coronary angiography over a 10-year period were screened for ICOCAD as defined by the National Heart, Lung, and Blood Institute. The management and all-cause mortality were retrieved from local and national databases. RESULTS: The overall prevalence of ICOCAD was 0.09% (51/55,968 patients). Guide catheters accounted for 75% (n = 37) of cases. Half of the ICOCAD cases involved the right coronary artery while the remaining were related to left main stem (23/51; 45%) and left internal mammary artery (2/51; 4%). Two-thirds of ICOCAD were high grade (type D, E, and F). The majority of cases were type F dissections (n = 18; 66%), of which two third occurred in females in their 60s. The majority of ICOCAD patients (42/51; 82%) were treated with percutaneous coronary intervention while the remaining underwent coronary artery bypass grafting (3/51; 6%) or managed conservatively (6/51; 12%). Three deaths occurred during the index admission while 48/51 patients (94.1%) were safely discharged without further mortality over a median follow-up of 3.6 years. CONCLUSIONS: ICOCAD is a rare but life-threatening complication of coronary angiography. Timely recognition and prompt bailout PCI is a safe option for majority of patients with good clinical outcomes.


Asunto(s)
Intervención Coronaria Percutánea , Catéteres , Angiografía Coronaria , Vasos Coronarios , Disección , Femenino , Humanos , Enfermedad Iatrogénica , Intervención Coronaria Percutánea/efectos adversos , Prevalencia , Resultado del Tratamiento
7.
Eur Heart J ; 41(31): 2997-3004, 2020 08 14.
Artículo en Inglés | MEDLINE | ID: mdl-32402086

RESUMEN

Despite advanced understanding of the biology of atherosclerosis, coronary heart disease remains the leading cause of death worldwide. Progress has been challenging as half of the individuals who suffer sudden cardiac death do not experience premonitory symptoms. Furthermore, it is well-recognized that also a plaque that does not cause a haemodynamically significant stenosis can trigger a sudden cardiac event, yet the majority of ruptured or eroded plaques remain clinically silent. In the past 30 years since the term 'vulnerable plaque' was introduced, there have been major advances in the understanding of plaque pathogenesis and pathophysiology, shifting from pursuing features of 'vulnerability' of a specific lesion to the more comprehensive goal of identifying patient 'cardiovascular vulnerability'. It has been also recognized that aside a thin-capped, lipid-rich plaque associated with plaque rupture, acute coronary syndromes (ACS) are also caused by plaque erosion underlying between 25% and 60% of ACS nowadays, by calcified nodule or by functional coronary alterations. While there have been advances in preventive strategies and in pharmacotherapy, with improved agents to reduce cholesterol, thrombosis, and inflammation, events continue to occur in patients receiving optimal medical treatment. Although at present the positive predictive value of imaging precursors of the culprit plaques remains too low for clinical relevance, improving coronary plaque imaging may be instrumental in guiding pharmacotherapy intensity and could facilitate optimal allocation of novel, more aggressive, and costly treatment strategies. Recent technical and diagnostic advances justify continuation of interdisciplinary research efforts to improve cardiovascular prognosis by both systemic and 'local' diagnostics and therapies. The present state-of-the-art document aims to present and critically appraise the latest evidence, developments, and future perspectives in detection, prevention, and treatment of 'high-risk' plaques occurring in 'vulnerable' patients.


Asunto(s)
Síndrome Coronario Agudo , Aterosclerosis , Enfermedad de la Arteria Coronaria , Enfermedad Coronaria , Placa Aterosclerótica , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Humanos , Placa Aterosclerótica/diagnóstico por imagen
8.
J Interv Cardiol ; 2020: 6381637, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32395091

RESUMEN

Fractional flow reserve is the gold standard for assessing the haemodynamic significance of intermediate coronary artery stenoses. Cumulative evidence has shown that FFR-guided revascularisation reduces stent implantations and improves patient outcomes. However, despite the wealth of evidence and guideline recommendations, its use in clinical practice remains minimal. Patient and technical limitations of FFR as well as the need for intracoronary instrumentation, use of adenosine, and increased costs have limited FFR's applicability in clinical practice. Over the last decade, several angiography-derived FFR software packages have been developed which do not require intracoronary pressure assessment with a guidewire or need for administration of hyperaemic agents. At present, there are 3 commercially available software packages and several other non-commercial technologies that have been described in the literature. These technologies have been validated against invasive FFR showing good accuracy and correlation. However, the methodology behind these solutions is different-some algorithms are based on solving the governing equations of fluid dynamics such as the Navier-Stokes equation while others have opted for a more simplified mathematical formula approach. The aim of this review is to critically appraise the methodology behind all the known angiography-derived FFR technologies highlighting the key differences and limitations.


Asunto(s)
Angiografía Coronaria , Estenosis Coronaria/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico , Procesamiento de Imagen Asistido por Computador , Adenosina , Hemodinámica , Humanos , Valor Predictivo de las Pruebas
9.
Cardiology ; 145(5): 285-293, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32289784

RESUMEN

Computed tomographic coronary angiography (CTCA) is a non-invasive imaging modality, which allows plaque burden and composition assessment and detection of plaque characteristics associated with increased vulnerability. In addition, CTCA-based coronary artery reconstruction enables local haemodynamic forces assessment, which regulate plaque formation and vascular inflammation and prediction of lesions that are prone to progress and cause events. However, the use of CTCA for vulnerable plaque detection in the clinical arena remains limited. To unlock the full potential of CTCA and enable its broad use, further work is needed to develop user-friendly processing tools that will allow fast and accurate analysis of CTCA, computational fluid dynamic modelling, and evaluation of the local haemodynamic forces. The present study aims to develop a seamless platform that will overcome the limitations of CTCA and enable fast and accurate evaluation of plaque morphology and physiology. We will analyse imaging data from 70 patients with coronary artery disease who will undergo state-of-the-art CTCA and near-infrared spectroscopy-intravascular ultrasound imaging and develop and train algorithms that will take advantage of the intravascular imaging data to optimise vessel segmentation and plaque characterisation. Furthermore, we will design an advanced module that will enable reconstruction of coronary artery anatomy from CTCA, blood flow simulation, shear stress estimation, and comprehensive visualisation of vessel pathophysiology. These advances are expected to facilitate the broad use of CTCA, not only for risk stratification but also for the evaluation of the effect of emerging therapies on plaque evolution.


Asunto(s)
Enfermedad de la Arteria Coronaria , Análisis de Datos , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Humanos , Ultrasonografía Intervencional
10.
Am Heart J ; 218: 20-31, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31655414

RESUMEN

Intravascular imaging has enabled in vivo assessment of coronary artery pathology and detection of plaque characteristics that are associated with increased vulnerability. Prospective invasive imaging studies of coronary atherosclerosis have demonstrated that invasive imaging modalities can detect lesions that are likely to progress and cause cardiovascular events and provided unique insights about atherosclerotic evolution. However, despite the undoubted value of the existing imaging techniques in clinical and research arenas, all the available modalities have significant limitations in assessing plaque characteristics when compared with histology. Hybrid/multimodality intravascular imaging appears able to overcome some of the limitations of standalone imaging; however, there are only few histology studies that examined their performance in evaluating plaque pathobiology. In this article, we review the evidence about the efficacy of standalone and multi-modality/hybrid intravascular imaging in assessing plaque morphology against histology, highlight the advantages and limitations of the existing imaging techniques and discuss the future potential of emerging imaging modalities in the study of atherosclerosis.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Procedimientos Endovasculares/métodos , Imagen Multimodal/métodos , Placa Aterosclerótica/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/patología , Endosonografía , Predicción , Humanos , Técnicas Fotoacústicas/métodos , Placa Aterosclerótica/patología , Ondas de Radio , Espectrometría de Fluorescencia , Espectroscopía Infrarroja Corta , Tomografía de Coherencia Óptica
11.
Circ J ; 84(1): 91-100, 2019 12 25.
Artículo en Inglés | MEDLINE | ID: mdl-31735729

RESUMEN

BACKGROUND: Attenuation-compensated (AC) technique was recently introduced to improve the plaque characterization of optical coherence tomography (OCT). Histological validation demonstrated promising results but the efficacy and reproducibility of this technique for assessing in-vivo tissue composition remains unclear.Methods and Results:OCT images portraying native (n=200) and stented (n=200) segments and 31 histological cross-sections were analyzed. AC-OCT appeared superior to conventional (C)-OCT in detecting the external elastic lamina (EEM) borders (76% vs. 65.5%); AC-OCT enabled larger EEM arc detection compared with C-OCT (174.2±58.7° vs. 137.5±57.9°; P<0.001). There was poor agreement between the 2 techniques for detection of lipid in native and lipid and calcific tissue in stented segments (κ range: 0.164-0.466) but the agreement of C-OCT and AC-OCT was high for calcific tissue in native segments (κ=0.825). Intra and interobserver agreement of the 2 analysts was moderate to excellent with C-OCT (κ range: 0.681-0.979) and AC-OCT (κ range: 0.733-0.892) for all tissue types in both native and stented segments. Ex-vivoanalysis demonstrated that C-OCT was superior to AC-OCT (κ=0.545 vs. κ=0.296) for the detection of the lipid component in native segments. CONCLUSIONS: The AC technique allows better delineation of the EEM but it remains inferior for lipid pool detection and neointima characterization. Combined AC- and C-OCT imaging may provide additional value for complete assessment of plaque and neointima characteristics.


Asunto(s)
Enfermedad de la Arteria Coronaria , Vasos Coronarios , Placa Aterosclerótica , Tomografía de Coherencia Óptica , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/metabolismo , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/metabolismo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Placa Aterosclerótica/diagnóstico por imagen , Placa Aterosclerótica/metabolismo
12.
Eur Heart J ; 39(18): 1602-1609, 2018 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-29409057

RESUMEN

Aims: As a sine qua non for arterial wall physiology, local hemodynamic forces such as endothelial shear stress (ESS) may influence long-term vessel changes as bioabsorbable scaffolds dissolve. The aim of this study was to perform serial computational fluid dynamic (CFD) simulations to examine immediate and long-term haemodynamic and vascular changes following bioresorbable scaffold placement. Methods and results: Coronary arterial models with long-term serial assessment (baseline and 5 years) were reconstructed through fusion of intravascular optical coherence tomography and angiography. Pulsatile non-Newtonian CFD simulations were performed to calculate the ESS and relative blood viscosity. Time-averaged, systolic, and diastolic results were compared between follow-ups. Seven patients (seven lesions) were included in this analysis. A marked heterogeneity in ESS and localised regions of high blood viscosity were observed post-implantation. Percent vessel area exposed to low averaged ESS (<1 Pa) significantly decreased over 5 years (15.92% vs. 4.99%, P < 0.0001) whereas moderate (1-7 Pa) and high ESS (>7 Pa) did not significantly change (moderate ESS: 76.93% vs. 80.7%, P = 0.546; high ESS: 7.15% vs. 14.31%, P = 0.281), leading to higher ESS at follow-up. A positive correlation was observed between baseline ESS and change in lumen area at 5 years (P < 0.0001). Maximum blood viscosity significantly decreased over 5 years (4.30 ± 1.54 vs. 3.21± 0.57, P = 0.028). Conclusion: Immediately after scaffold implantation, coronary arteries demonstrate an alternans of extremely low and high ESS values and localized areas of high blood viscosity. These initial local haemodynamic disturbances may trigger fibrin deposition and thrombosis. Also, low ESS can promote neointimal hyperplasia, but may also contribute to appropriate scaffold healing with normalisation of ESS and reduction in peak blood viscosity by 5 years.


Asunto(s)
Implantes Absorbibles , Vasos Coronarios/patología , Vasos Coronarios/fisiopatología , Endotelio Vascular/patología , Endotelio Vascular/fisiopatología , Modelos Cardiovasculares , Andamios del Tejido , Fenómenos Biomecánicos , Vasos Coronarios/cirugía , Endotelio Vascular/cirugía , Hidrodinámica , Imagenología Tridimensional , Estrés Mecánico , Factores de Tiempo , Tomografía de Coherencia Óptica
13.
Catheter Cardiovasc Interv ; 91(6): 1084-1091, 2018 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-28843033

RESUMEN

BACKGROUND: The shear stress distribution assessment can provide useful insights for the hemodynamic performance of the implanted stent/scaffold. Our aim was to investigate the effect of a novel bioresorbable scaffold, Mirage on local hemodynamics in animal models. METHOD: The main epicardial coronary arteries of 7 healthy mini-pigs were implanted with 11 Mirage Microfiber sirolimus-eluting Bioresorbable Scaffolds (MMSES). Optical coherence tomography (OCT) was performed post scaffold implantation and the obtained images were fused with angiographic data to reconstruct the coronary artery anatomy. Blood flow simulation was performed and Endothelial Shear Stress(ESS) distribution was estimated for each of the 11 scaffolds. ESS data were extracted in each circumferential 5-degree subunit of each cross-section in the scaffolded segment. The generalized linear mixed-effect analysis was implemented for the comparison of ESS in two scaffold groups; 150-µm strut thickness MMSES and 125-µm strut thickness MMSES. RESULTS: ESS was significantly higher in MMSES (150 µm) [0.85(0.49-1.40) Pa], compared to MMSES (125 µm) [0.68(0.35-1.18) Pa]. Both MMSES (150 µm) and MMSES (125 µm) revealed low recirculation zone percentages per luminal surface area [3.17% ± 1.97% in MMSES (150 µm), 2.71% ± 1.32% in MMSES (125 µm)]. CONCLUSION: Thinner strut Mirage scaffolds induced lower shear stress due to the small size vessels treated as compared to the thick strut version of the Mirage which was implanted in relatively bigger size vessels. Vessel size should be taken into account in planning BRS implantation. Small vessels may not get benefit from BRS implantation even with a streamlined strut profile. This pilot study warrants comparative assessment with commercially available bioresorbable scaffolds.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Vasos Coronarios/cirugía , Hemodinámica , Intervención Coronaria Percutánea/instrumentación , Sirolimus/administración & dosificación , Animales , Velocidad del Flujo Sanguíneo , Simulación por Computador , Circulación Coronaria , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Modelos Animales , Modelos Cardiovasculares , Diseño de Prótesis , Estrés Mecánico , Porcinos , Porcinos Enanos , Factores de Tiempo , Tomografía de Coherencia Óptica
14.
Arterioscler Thromb Vasc Biol ; 37(12): 2231-2242, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-29122816

RESUMEN

Local hemodynamic forces are well-known to modulate atherosclerotic evolution, which remains one of the largest cause of death worldwide. Percutaneous coronary interventions with stent implantation restores blood flow to the downstream myocardium and is only limited by stent failure caused by restenosis, stent thrombosis, or neoatherosclerosis. Cumulative evidence has shown that local hemodynamic forces affect restenosis and the platelet activation process, modulating the pathophysiological mechanisms that lead to stent failure. This article first covers the pathophysiological mechanisms through which wall shear stress regulates arterial disease formation/neointima proliferation and the role of shear rate on stent thrombosis. Subsequently, the article reviews the current evidence on (1) the implications of stent design on the local hemodynamic forces, and (2) how stent/scaffold expansion can influence local flow, thereby affecting the risk of adverse events.


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Circulación Coronaria , Reestenosis Coronaria/etiología , Trombosis Coronaria/etiología , Vasos Coronarios/fisiopatología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Stents , Animales , Proliferación Celular , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/patología , Reestenosis Coronaria/fisiopatología , Trombosis Coronaria/diagnóstico por imagen , Trombosis Coronaria/fisiopatología , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Endotelio Vascular/fisiopatología , Hemodinámica , Humanos , Neointima , Diseño de Prótesis , Falla de Prótesis , Factores de Riesgo , Estrés Mecánico , Resultado del Tratamiento
15.
Eur Heart J ; 38(2): 81-92, 2017 01 07.
Artículo en Inglés | MEDLINE | ID: mdl-28158723

RESUMEN

Coronary plaque rupture is the most common cause of vessel thrombosis and acute coronary syndrome. The accurate early detection of plaques prone to rupture may allow prospective, preventative treatment; however, current diagnostic methods remain inadequate to detect these lesions. Established imaging features indicating vulnerability do not confer adequate specificity for symptomatic rupture. Similarly, even though experimental and computational studies have underscored the importance of endothelial shear stress in progressive atherosclerosis, the ability of shear stress to predict plaque progression remains incremental. This review examines recent advances in image-based computational modelling that have elucidated possible mechanisms of plaque progression and rupture, and potentially novel features of plaques most prone to symptomatic rupture. With further study and clinical validation, these markers and techniques may improve the specificity of future culprit plaque detection.


Asunto(s)
Enfermedad de la Arteria Coronaria/fisiopatología , Estrés Fisiológico/fisiología , Adaptación Fisiológica/fisiología , Fenómenos Biomecánicos/fisiología , Técnicas de Imagen Cardíaca , Colesterol/metabolismo , Simulación por Computador , Cristalización , Progresión de la Enfermedad , Endotelio Vascular/fisiología , Humanos , Placa Aterosclerótica/fisiopatología , Rotura Espontánea/fisiopatología , Calcificación Vascular/fisiopatología , Remodelación Vascular/fisiología
16.
Eur Heart J ; 38(6): 400-412, 2017 02 07.
Artículo en Inglés | MEDLINE | ID: mdl-27118197

RESUMEN

Cumulative evidence from histology-based studies demonstrate that the currently available intravascular imaging techniques have fundamental limitations that do not allow complete and detailed evaluation of plaque morphology and pathobiology, limiting the ability to accurately identify high-risk plaques. To overcome these drawbacks, new efforts are developing for data fusion methodologies and the design of hybrid, dual-probe catheters to enable accurate assessment of plaque characteristics, and reliable identification of high-risk lesions. Today several dual-probe catheters have been introduced including combined near infrared spectroscopy-intravascular ultrasound (NIRS-IVUS), that is already commercially available, IVUS-optical coherence tomography (OCT), the OCT-NIRS, the OCT-near infrared fluorescence (NIRF) molecular imaging, IVUS-NIRF, IVUS intravascular photoacoustic imaging and combined fluorescence lifetime-IVUS imaging. These multimodal approaches appear able to overcome limitations of standalone imaging and provide comprehensive visualization of plaque composition and plaque biology. The aim of this review article is to summarize the advances in hybrid intravascular imaging, discuss the technical challenges that should be addressed in order to have a use in the clinical arena, and present the evidence from their first applications aiming to highlight their potential value in the study of atherosclerosis.


Asunto(s)
Técnicas de Imagen Cardíaca/tendencias , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Imagen Multimodal/tendencias , Placa Aterosclerótica/diagnóstico por imagen , Angiografía por Tomografía Computarizada/tendencias , Angiografía Coronaria/tendencias , Angiografía con Fluoresceína/tendencias , Humanos , Técnicas Fotoacústicas/tendencias , Espectroscopía Infrarroja Corta/tendencias , Tomografía de Coherencia Óptica/tendencias , Ultrasonografía Intervencional/tendencias
17.
Heart Lung Circ ; 27(3): 377-380, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28506646

RESUMEN

BACKGROUND: Fractional flow reserve (FFR) has been established as a useful diagnostic tool. The distal coronary pressure to aortic pressure (Pd/Pa) ratio at rest is a simpler physiologic index but also requires the use of the pressure wire, whereas recently proposed virtual functional indices derived from coronary imaging require complex blood flow modelling and/or are time-consuming. Our aim was to test the diagnostic performance of virtual resting Pd/Pa using routine angiographic images and a simple flow model. METHODS: Three-dimensional quantitative coronary angiography (3D-QCA) was performed in 139 vessels (120 patients) with intermediate lesions assessed by FFR. The resting Pd/Pa for each lesion was assessed by computational fluid dynamics. RESULTS: The discriminatory power of virtual resting Pd/Pa against FFR (reference: ≤0.80) was high (area under the receiver operator characteristic curve [AUC]: 90.5% [95% CI: 85.4-95.6%]). Diagnostic accuracy, sensitivity and specificity for the optimal virtual resting Pd/Pa cut-off (≤0.94) were 84.9%, 90.4% and 81.6%, respectively. Virtual resting Pd/Pa demonstrated superior performance (p<0.001) versus 3D-QCA %area stenosis (AUC: 77.5% [95% CI: 69.8-85.3%]). There was a good correlation between virtual resting Pd/Pa and FFR (r=0.69, p<0.001). CONCLUSIONS: Virtual resting Pd/Pa using routine angiographic data and a simple flow model provides fast functional assessment of coronary lesions without requiring the pressure-wire and hyperaemia induction. The high diagnostic performance of virtual resting Pd/Pa for predicting FFR shows promise for using this simple/fast virtual index in clinical practice.


Asunto(s)
Angiografía Coronaria/métodos , Oclusión Coronaria/diagnóstico , Estenosis Coronaria/diagnóstico , Reserva del Flujo Fraccional Miocárdico/fisiología , Imagenología Tridimensional , Flujo Sanguíneo Regional/fisiología , Anciano , Enfermedad Crónica , Oclusión Coronaria/fisiopatología , Estenosis Coronaria/fisiopatología , Vasos Coronarios/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Curva ROC
18.
Catheter Cardiovasc Interv ; 87 Suppl 1: 589-98, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26876688

RESUMEN

OBJECTIVE: This study investigated the diagnostic accuracy of three-dimensional quantitative coronary angiography (3D-QCA) compared with conventional 2D-QCA for predicting functional severity assessed by fractional flow reserve (FFR) for true bifurcation lesions. METHODS: Based on pooled data from the randomized DK-CRUSH II, III, and IV trials, we evaluated the patients with true bifurcation lesions who underwent coronary angiography together with functional evaluations using FFR in both the main vessel and the side branch. Off-line 2D- and 3D-QCA analyses were conducted using dedicated bifurcation QCA analysis software. Measurements of minimum lumen diameter (MLD), percentage diameter stenosis (% DS), and minimum lumen area (MLA) were compared between 2D- and 3D-QCA, and we evaluated their predictive values of functionally significant FFR. RESULTS: Ninety patients were eligible for enrollment in the present study. In the main vessel, MLA measured by 3D-QCA was the most accurate predictor of FFR <0.75 (C statistic 0.85, P < 0.001), while MLD measured by 2D-QCA was a similarly accurate predictor (C statistic 0.85, P < 0.001). In the side branch, the best metrics for predicting FFR <0.75 were % DS measured by 2D-QCA with a C statistic value of 0.91 (P < 0.001) and MLA measured by 3D-QCA with a C statistic value of 0.81 (P < 0.001). However, both 2D- and 3D-QCA metrics exhibited low accuracies for predicting FFR <0.75 in intermediate bifurcation lesions. CONCLUSIONS: 3D-QCA analysis for true bifurcation lesions did not improve the predictive accuracy of functionally significant FFR compared with 2D-QCA analysis. In lesions with intermediate stenosis, the diagnostic performance of both 2D- and 3D-QCA-derived measurements in differentiating functional severity is limited.


Asunto(s)
Angiografía Coronaria/instrumentación , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Imagenología Tridimensional , Anciano , Ensayos Clínicos Fase IV como Asunto , Enfermedad de la Arteria Coronaria/fisiopatología , Estenosis Coronaria/fisiopatología , Vasos Coronarios/fisiopatología , Femenino , Reserva del Flujo Fraccional Miocárdico , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Interpretación de Imagen Radiográfica Asistida por Computador , Ensayos Clínicos Controlados Aleatorios como Asunto , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Programas Informáticos
19.
Circ Res ; 114(6): 1037-51, 2014 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-24625728

RESUMEN

Transcatheter aortic valve replacement emerged ≈20 years ago and changed the landscape of structural interventional cardiology. The first experiments in animal models provided proofs of the concept and the substrate for the first percutaneous valve implantation in patients. The initial promising results in a clinical setting drew the attention of the industry and of the scientific community, and an effort was made for the past 12 years to address the limitations of the technology, facilitate the procedure, minimize the risk of complications, and broaden the applications of transcatheter aortic valve replacement. This article reviews the evolution of transcatheter aortic valve replacement, presents the first steps in this field, cites the evidence from registries and clinical trials, highlights the limitations of this treatment, and discusses the future perspectives and the developments proposed to address the current pitfalls.


Asunto(s)
Válvula Aórtica/cirugía , Procedimientos Endovasculares/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Arritmias Cardíacas/etiología , Cateterismo Cardíaco , Ensayos Clínicos como Asunto , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/tendencias , Diseño de Equipo , Falla de Equipo , Cardiopatías/etiología , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/tendencias , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos , Estudios Multicéntricos como Asunto , Marcapaso Artificial , Selección de Paciente , Inhibidores de Agregación Plaquetaria/uso terapéutico , Complicaciones Posoperatorias , Premedicación , Pronóstico , Ensayos Clínicos Controlados Aleatorios como Asunto , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control
20.
BMC Cardiovasc Disord ; 16: 38, 2016 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-26868826

RESUMEN

Numerous advances and innovative therapies have been introduced in interventional cardiology over the recent years, since the first introduction of balloon angioplasty, but bioresorbable scaffold is certainly one of the most exciting and attracting one. Despite the fact that the metallic drug-eluting stents have significantly diminished the re-stenosis ratio, they have considerable limitations including the hypersensitivity reaction to the polymer that can cause local inflammation, the risk of neo-atherosclerotic lesion formation which can lead to late stent failure as well as the fact that they may preclude surgical revascularization and distort vessel physiology. Bioresorbable scaffolds overcome these limitations as they have the ability to dissolve after providing temporary scaffolding which safeguards vessel patency. In this article we review the recent developments in the field and provide an overview of the devices and the evidence that support their efficacy in the treatment of CAD. Currently 3 devices are CE marked and in clinical use. Additional 24 companies are developing these kind of coronary devices. Most frequently used material is PLLA followed by magnesium.


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria/cirugía , Intervención Coronaria Percutánea , Diseño de Prótesis , Stents , Andamios del Tejido , Angioplastia Coronaria con Balón , Humanos , Grado de Desobstrucción Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA