Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Vet Radiol Ultrasound ; 62(2): 190-198, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33350535

RESUMEN

Computed tomographic (CT) excretory urography is commonly used to investigate canine ureteral ectopia (UE). Modern technology allows time-resolved CT imaging (four-dimensional CT excretory urography [4D-CTEU]) over a distance exceeding the detector collimation. Objectives of this prospective, observational, diagnostic accuracy study were to evaluate the diagnostic accuracy of CT excretory urography (CTEU) and 4D-CTEU for UE in dogs with lower urinary tract signs, assess the influence of pelvis positioning, and to determine the significance of the ureterovesical junction (UVJ) angle for UE diagnosis. Thirty-six dogs, with a total of 42 normotopic ureters, 27 intramural ectopic ureters, and three extramural ectopic ureters, underwent CTEU and 4D-CTEU with randomized pelvis positioning. Randomized CTEU and 4D-CTEU studies were scored by two observers for ureteral papilla location and murality on a grading scheme. Interobserver agreement, sensitivity, and specificity for ureter topia status and diagnosis were calculated. Computed tomographic excretory urography showed moderate interobserver agreement for the left ureter and perfect for the right ureter, whereas 4D-CTEU showed bilateral nearly perfect agreement between both observers. When comparing CTEU versus confirmed diagnosis, there was a sensitivity and specificity of 73% and 90.2%, respectively, whereas 4D-CTEU showed a sensitivity and specificity of 97% and 94.6%, respectively. An obtuse UVJ angle is significantly more commonly observed in ectopic intramural than normotopic ureters and is significantly associated with increased diagnostic confidence of UE. The use of a wedge to angle the pelvis did not increase the diagnostic confidence in determining ureteral opening position. Four-dimensional CT excretory urography is an accurate and reliable diagnostic technique to investigate UE as cause of urinary incontinence in dogs that is slightly superior to CTEU.


Asunto(s)
Enfermedades de los Perros/diagnóstico por imagen , Tomografía Computarizada Cuatridimensional/veterinaria , Enfermedades Ureterales/veterinaria , Urografía/veterinaria , Animales , Enfermedades de los Perros/patología , Perros , Femenino , Tomografía Computarizada Cuatridimensional/métodos , Masculino , Estudios Prospectivos , Uréter , Enfermedades Ureterales/diagnóstico por imagen , Enfermedades Ureterales/patología , Vejiga Urinaria , Incontinencia Urinaria/veterinaria
2.
J Zoo Wildl Med ; 47(1): 6-11, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27010258

RESUMEN

Electrocardiography represents a relevant diagnostic tool for detecting cardiac disease in animals. Elephants can present various congenital and acquired cardiovascular diseases. However, few electrophysiologic studies have been reported in captive elephants, mainly due to challenging technical difficulties in obtaining good-quality electrocardiogram (ECG) tracings, and no data are currently available for free-ranging Asian elephants (Elephas maximus). The purpose of this pilot prospective study was to evaluate the feasibility of using a simple method for recording ECG tracings in wild, apparently healthy, unsedated Asian elephants (n = 7) in the standing position. Successful six-lead recordings (I, II, III, aVR, aVL, and aVF) were obtained, with the aVL lead providing the best-quality tracings in most animals. Variables measured in the aVL lead included heart rate, amplitudes and duration of the P waves, QRS complexes, T and U waves, and duration of the PR, QT, and QU intervals. A negative deflection following positive P waves, representative of an atrial repolarization wave (Ta wave), was observed for five out of the seven elephants.


Asunto(s)
Electrocardiografía/veterinaria , Elefantes/fisiología , Animales , Animales de Zoológico , Electrocardiografía/métodos , Femenino , Masculino , Valores de Referencia
3.
Open Vet J ; 12(4): 562-566, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36118718

RESUMEN

Background: The acquisition of systemic blood pressure (SBP) provides valuable information regarding cardiovascular function and tissue perfusion in human and veterinary species. Aim: To evaluate the agreement between Parks Medical Doppler (PMD) and Mano Médical Vet BP (MMVBP) Doppler for assessing SBP in conscious dogs. Methods: 40 client-owned dogs were prospectively enrolled; SBP measurements were acquired by a single operator using the PMD and then the MMVBP. The mean of five consecutive measurements for each device was classified according to target organ damage (TOD) risk scores (1: <140 mmHg; 2: 140-160 mmHg; 3: 160-180 mmHg; 4: ≥ 180 mmHg). Results: Total mean SBP for the devices was not statistically different (p = 0.77). However, the Bland-Altman analysis revealed wide limits of agreement (LoA), with MMVBP slightly underestimating SBP compared to PMD (bias = -0.6 mmHg, 95% LoA: -26.3 to 25.09). Both devices correlated well ( r = 0.8269; p < 0.0001) and had identically acceptable intra-observer repeatability (coefficients of variation = 4.09% for MMVBP and 3.86% for PMD). Four dogs (10%) had a TOD score of 3 by one device but scored <3 with the other. Conclusion: A good agreement and correlation was observed between the PMD and the MMVBP, suggesting that both devices can be used interchangeably for assessment of SBP in conscious dogs. The wide LoA observed between both devices was most likely associated with intraindividual variability in SBP over time.


Asunto(s)
Determinación de la Presión Sanguínea , Ultrasonografía Doppler , Animales , Presión Sanguínea/fisiología , Determinación de la Presión Sanguínea/veterinaria , Perros , Humanos , Oscilometría/veterinaria , Ultrasonografía Doppler/veterinaria
4.
Vet Rec ; 186(19): e29, 2020 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-32201381

RESUMEN

INTRODUCTION: Corn snakes are a very common pet reptile species, yet there is an absence of evidence-based literature standardising collection of ECG or detailing ECG deflection morphology in the normal animal. The authors describe a well-tolerated, reproducible technique and detail the cardiac cycle in terms of lead 2 equivalent waveforms and intervals. ANIMALS: 29 adult corn snakes. MATERIALS AND METHODS: This prospective study evaluated, under species-appropriate, standardised conditions, a technique for producing standard six-lead ECG tracings. Lead 2 equivalent cardiac cycles were described in detail and statistically analysed for sex, weight, length, heart rate and mean electrical axis. RESULTS: High-quality tracings demonstrated common ECG characteristics for this species, including no Q, S or SV waves, prolonged PR and RT intervals, rhythmic oscillation of the baseline, short TP segments, and a right displaced mean electrical axis. An influence of sex, weight or length on heart rate and mean electrical axis was not identified. CONCLUSIONS: To the authors' knowledge, this is the first study to describe a standardised technique for recording ECG in significant numbers of normal corn snakes. Ranges have been provided that may be of diagnostic value or form the basis for future development of reference intervals for this species.


Asunto(s)
Colubridae/fisiología , Electrocardiografía/veterinaria , Corazón/fisiología , Animales , Electrocardiografía/normas , Femenino , Frecuencia Cardíaca/fisiología , Masculino , Estudios Prospectivos , Estándares de Referencia
5.
J Vet Cardiol ; 24: 64-77, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31405556

RESUMEN

INTRODUCTION: We hypothesized that real-time three-dimensional echocardiography (RT-3DE) was superior to two-dimensional echocardiography for the estimation of left atrial volume (LAV), using electrocardiographic (ECG)-gated multidetector computed tomography angiography (MDCTA) as a volumetric gold standard. The aim was to compare maximum LAV (LAVmax) and minimum LAV (LAVmin) measured by biplane area-length method (ALM), biplane method of disk (MOD) and RT-3DE with 64-slice ECG-gated MDCTA in dogs ANIMALS: The study included twenty dogs, anaesthetized for various diagnostic purposes and without evidence of cardiovascular disease. METHODS: Left atrial volume was estimated by ALM, MOD and RT-3DE following ECG-gated MDCTA. The results were compared with LAV from MDCTA and correlations were performed. The limits of agreement (LoA) between methods were evaluated using Bland-Altman analysis and intraclass correlations. Coefficients of variation were calculated. RESULTS: Area-length method (r = 0.79 and 0.72), MOD (r = 0.81 and 0.70) and RT-3DE (r = 0.94 and 0.82) correlated with MDCTA for LAVmax and LAVmin, respectively (all p < 0.05). Biases for LAVmax (-0.96 mL, 95% LoA: -5.6 to 3.7) and LAVmin (-0.67 mL, 95% LoA: -5.4 - 4.1) were minimal with RT-3DE, reflecting a slight underestimation. Conversely, MOD (LAVmaxbias = 3.19 mL, 95% LoA: -5.7 - 12.1; LAVminbias = 1.96 mL, 95% LoA: -4.6 - 8.5) and ALM (LAVmaxbias = 4.05, 95% LoA: -5.7 - 13.8; LAVminbias = 2.80 mL, 95% LoA: -3.9 - 9.5) suggested LAV overestimation. Intraobserver and interobserver variability were adequate. CONCLUSIONS: Real-time three-dimensional echocardiography is a non-invasive, accurate and feasible method with superior accuracy to two-dimensional methods.


Asunto(s)
Perros/anatomía & histología , Atrios Cardíacos/anatomía & histología , Animales , Ecocardiografía/veterinaria , Ecocardiografía Tridimensional/veterinaria , Femenino , Atrios Cardíacos/diagnóstico por imagen , Masculino , Tomografía Computarizada Multidetector/veterinaria , Estudios Prospectivos , Valores de Referencia
6.
Am J Vet Res ; 80(4): 347-357, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30919673

RESUMEN

OBJECTIVE: To determine variability of global longitudinal strain (GLS) and strain rate (SR) measurements in dogs with and without cardiac disease derived from 2-D speckle tracking echocardiography (STE) by use of various software. ANIMALS: 2 cohorts comprising 44 dogs (23 cardiovascularly healthy and 21 with cardiac disease) and 40 dogs (18 cardiovascularly healthy and 22 with cardiac disease). PROCEDURES: Transthoracic echocardiographic images in each cohort were analyzed with vendor-independent software and vendor-specific 2-D STE software for each of 2 vendors. Values for GLS and SR obtained from the same left parasternal apical views with various software were compared. Intraobserver and interobserver variability was determined, and agreement among results for the various software was assessed. RESULTS: Strain analysis was not feasible with vendor-independent software for 20% of images obtained with the ultrasonography system of vendor 1. Intraobserver and interobserver coefficient of variation was < 10% for GLS values, whereas SR measurements had higher variance. There was a significant difference in GLS and SR obtained for each cohort with different software. Evaluation of Bland-Altman plots revealed wide limits of agreement, with variance for GLS of up to 6.3 units in a single dog. CONCLUSIONS AND CLINICAL RELEVANCE: Results of longitudinal strain analysis were not uniform among software, and GLS was the most reproducible measurement. Significant variability in results among software warrants caution when referring to reference ranges or comparing serial measurements in the same patient because changes of < 6.5% in GLS might be within measurement error for different postprocessing software.


Asunto(s)
Enfermedades de los Perros/fisiopatología , Ecocardiografía/veterinaria , Cardiopatías/veterinaria , Programas Informáticos , Animales , Estudios de Cohortes , Perros , Femenino , Cardiopatías/fisiopatología , Ventrículos Cardíacos , Masculino , Variaciones Dependientes del Observador , Valores de Referencia , Reproducibilidad de los Resultados , Especificidad de la Especie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA