Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
BMJ Open ; 13(12): e075070, 2023 12 14.
Artículo en Inglés | MEDLINE | ID: mdl-38101848

RESUMEN

INTRODUCTION: Transfusions in surgery can be life-saving interventions, but inappropriate transfusions may lack clinical benefit and cause harm. Transfusion decision-making in surgery is complex and frequently informed by haemoglobin (Hgb) measurement in the operating room. Point-of-care testing for haemoglobin (POCT-Hgb) is increasingly relied on given its simplicity and rapid provision of results. POCT-Hgb devices lack adequate validation in the operative setting, particularly for Hgb values within the transfusion zone (60-100 g/L). This study aims to examine the accuracy of intraoperative POCT-Hgb instruments in non-cardiac surgery, and the association between POCT-Hgb measurements and transfusion decision-making. METHODS AND ANALYSIS: PREMISE is an observational prospective method comparison study. Enrolment will occur when adult patients undergoing major non-cardiac surgery require POCT-Hgb, as determined by the treating team. Three concurrent POCT-Hgb results, considered as index tests, will be compared with a laboratory analysis of Hgb (lab-Hgb), considered the gold standard. Participants may have multiple POCT-Hgb measurements during surgery. The primary outcome is the difference in individual Hgb measurements between POCT-Hgb and lab-Hgb, primarily among measurements that are within the transfusion zone. Secondary outcomes include POCT-Hgb accuracy within the entire cohort, postoperative morbidity, mortality and transfusion rates. The sample size is 1750 POCT-Hgb measurements to obtain a minimum of 652 Hgb measurements <100 g/L, based on an estimated incidence of 38%. The sample size was calculated to fit a logistic regression model to predict instances when POCT-Hgb are inaccurate, using 4 g/L as an acceptable margin of error. ETHICS AND DISSEMINATION: Institutional ethics approval has been obtained by the Ottawa Health Science Network-Research Ethics Board prior to initiating the study. Findings from this study will be published in peer-reviewed journals and presented at relevant scientific conferences. Social media will be leveraged to further disseminate the study results and engage with clinicians.


Asunto(s)
Transfusión Sanguínea , Hemoglobinas , Sistemas de Atención de Punto , Adulto , Humanos , Transfusión Sanguínea/métodos , Canadá , Hemoglobinas/análisis , Hospitales , Estudios Observacionales como Asunto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA