1.
Graefes Arch Clin Exp Ophthalmol ; 262(2): 431-440, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37843567

RESUMEN

PURPOSE: To assess the validity of the results of a freely available online Deep Learning segmentation tool and its sensitivity to noise introduced by cataract. METHODS: The OCT images were collected with a Spectralis SD-OCT (Heidelberg Engineering, Heidelberg, Germany) as part of normal clinical practice. Data were segmented using a freely available online tool called Relayer ( https://www.relayer.online/ ), based on a cross-platform Deep Learning segmentation architecture specifically adapted for retinal OCT images. The segmentations were read into MATLAB (The MathWorks, Natick, MA, USA) and analyzed. RESULTS: There was an excellent agreement between the ETDRS measurements obtained from the two algorithms. Upon visual inspection, the segmentation based on Deep Learning obtained with Relayer appeared more accurate except in one case of apparent good quality image showing interrupted segmentations in some of the B-scans. CONCLUSION: A freely available online Deep Learning segmentation tool showed good and promising performance in healthy retinas before and after cataract surgery, proving robust to optical degradation of the image from media opacities.


Asunto(s)
Catarata , Aprendizaje Profundo , Humanos , Tomografía de Coherencia Óptica/métodos , Retina , Catarata/diagnóstico , Algoritmos
2.
Scand J Med Sci Sports ; 33(7): 1104-1115, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36811255

RESUMEN

Predictors and mitigators of strain injuries have been studied in sprint-related sports. While the rate of axial strain, and thus running speed, may determine the site of muscle failure, muscle excitation seemingly offers protection against failure. It seems therefore plausible to ask whether running at different speeds changes the distribution of excitation within muscles. Technical limitations undermine, however, the possibility of addressing this issue in high-speed, ecological conditions. Here, we circumvent these limitations with a miniaturized, wireless, multi-channel amplifier, suited for collecting spatio-temporal data and high-density surface electromyograms (EMGs) during overground running. We segmented running cycles while 8 experienced sprinters ran at speeds close to (70% and 85%) and at (100%) their maximum, over an 80 m running track. Then, we assessed the effect of running speed on the distribution of excitation within biceps femoris (BF) and gastrocnemius medialis (GM). Statistical parametric mapping (SPM) revealed a significant effect of running speed on the amplitude of EMGs for both muscles, during late swing and early stance. Paired SPM revealed greater EMG amplitude when comparing 100% with 70% running speed for BF and GM. Regional differences in excitation were observed only for BF, however. As running speed increased from 70% to 100% of the maximum, a greater degree of excitation was observed at more proximal BF regions (from 2% to 10% of the thigh length) during late swing. We discuss how these results, in the context of the literature, support the protective role of pre-excitation against muscle failure, suggesting the site of BF muscle failure may depend on running speed.


Asunto(s)
Músculos Isquiosurales , Carrera , Humanos , Músculos Isquiosurales/fisiología , Músculo Esquelético/fisiología , Electromiografía , Carrera/fisiología
3.
J Neuroeng Rehabil ; 20(1): 78, 2023 06 14.
Artículo en Inglés | MEDLINE | ID: mdl-37316858

RESUMEN

BACKGROUND: Although digital mobility outcomes (DMOs) can be readily calculated from real-world data collected with wearable devices and ad-hoc algorithms, technical validation is still required. The aim of this paper is to comparatively assess and validate DMOs estimated using real-world gait data from six different cohorts, focusing on gait sequence detection, foot initial contact detection (ICD), cadence (CAD) and stride length (SL) estimates. METHODS: Twenty healthy older adults, 20 people with Parkinson's disease, 20 with multiple sclerosis, 19 with proximal femoral fracture, 17 with chronic obstructive pulmonary disease and 12 with congestive heart failure were monitored for 2.5 h in the real-world, using a single wearable device worn on the lower back. A reference system combining inertial modules with distance sensors and pressure insoles was used for comparison of DMOs from the single wearable device. We assessed and validated three algorithms for gait sequence detection, four for ICD, three for CAD and four for SL by concurrently comparing their performances (e.g., accuracy, specificity, sensitivity, absolute and relative errors). Additionally, the effects of walking bout (WB) speed and duration on algorithm performance were investigated. RESULTS: We identified two cohort-specific top performing algorithms for gait sequence detection and CAD, and a single best for ICD and SL. Best gait sequence detection algorithms showed good performances (sensitivity > 0.73, positive predictive values > 0.75, specificity > 0.95, accuracy > 0.94). ICD and CAD algorithms presented excellent results, with sensitivity > 0.79, positive predictive values > 0.89 and relative errors < 11% for ICD and < 8.5% for CAD. The best identified SL algorithm showed lower performances than other DMOs (absolute error < 0.21 m). Lower performances across all DMOs were found for the cohort with most severe gait impairments (proximal femoral fracture). Algorithms' performances were lower for short walking bouts; slower gait speeds (< 0.5 m/s) resulted in reduced performance of the CAD and SL algorithms. CONCLUSIONS: Overall, the identified algorithms enabled a robust estimation of key DMOs. Our findings showed that the choice of algorithm for estimation of gait sequence detection and CAD should be cohort-specific (e.g., slow walkers and with gait impairments). Short walking bout length and slow walking speed worsened algorithms' performances. Trial registration ISRCTN - 12246987.


Asunto(s)
Tecnología Digital , Fracturas Femorales Proximales , Humanos , Anciano , Marcha , Caminata , Velocidad al Caminar , Modalidades de Fisioterapia
4.
Sensors (Basel) ; 23(8)2023 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-37112261

RESUMEN

The analysis of the stability of human gait may be effectively performed when estimates of the base of support are available. The base of support area is defined by the relative position of the feet when they are in contact with the ground and it is closely related to additional parameters such as step length and stride width. These parameters may be determined in the laboratory using either a stereophotogrammetric system or an instrumented mat. Unfortunately, their estimation in the real world is still an unaccomplished goal. This study aims at proposing a novel, compact wearable system, including a magneto-inertial measurement unit and two time-of-flight proximity sensors, suitable for the estimation of the base of support parameters. The wearable system was tested and validated on thirteen healthy adults walking at three self-selected speeds (slow, comfortable, and fast). Results were compared with the concurrent stereophotogrammetric data, used as the gold standard. The root mean square errors for the step length, stride width and base of support area varied from slow to high speed between 10-46 mm, 14-18 mm, and 39-52 cm2, respectively. The mean overlap of the base of support area as obtained with the wearable system and with the stereophotogrammetric system ranged between 70% and 89%. Thus, this study suggested that the proposed wearable solution is a valid tool for the estimation of the base of support parameters out of the laboratory.


Asunto(s)
Caminata , Dispositivos Electrónicos Vestibles , Adulto , Humanos , Marcha , Pie , Fotogrametría
5.
J Neuroeng Rehabil ; 19(1): 141, 2022 12 16.
Artículo en Inglés | MEDLINE | ID: mdl-36522646

RESUMEN

BACKGROUND: Measuring mobility in daily life entails dealing with confounding factors arising from multiple sources, including pathological characteristics, patient specific walking strategies, environment/context, and purpose of the task. The primary aim of this study is to propose and validate a protocol for simulating real-world gait accounting for all these factors within a single set of observations, while ensuring minimisation of participant burden and safety. METHODS: The protocol included eight motor tasks at varying speed, incline/steps, surface, path shape, cognitive demand, and included postures that may abruptly alter the participants' strategy of walking. It was deployed in a convenience sample of 108 participants recruited from six cohorts that included older healthy adults (HA) and participants with potentially altered mobility due to Parkinson's disease (PD), multiple sclerosis (MS), proximal femoral fracture (PFF), chronic obstructive pulmonary disease (COPD) or congestive heart failure (CHF). A novelty introduced in the protocol was the tiered approach to increase difficulty both within the same task (e.g., by allowing use of aids or armrests) and across tasks. RESULTS: The protocol proved to be safe and feasible (all participants could complete it and no adverse events were recorded) and the addition of the more complex tasks allowed a much greater spread in walking speeds to be achieved compared to standard straight walking trials. Furthermore, it allowed a representation of a variety of daily life relevant mobility aspects and can therefore be used for the validation of monitoring devices used in real life. CONCLUSIONS: The protocol allowed for measuring gait in a variety of pathological conditions suggests that it can also be used to detect changes in gait due to, for example, the onset or progression of a disease, or due to therapy. TRIAL REGISTRATION: ISRCTN-12246987.


Asunto(s)
Marcha , Enfermedad de Parkinson , Adulto , Humanos , Caminata , Velocidad al Caminar , Proyectos de Investigación
6.
Int J Mol Sci ; 23(14)2022 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-35887233

RESUMEN

Low-molecular-weight, aspartic-acid-rich proteins (ASP-RICH) have been assumed to be involved in the self-incompatibility process of clementine. The role of ASP-RICH is not known, but hypothetically they could sequester calcium ions (Ca2+) and affect Ca2+-dependent mechanisms. In this article, we analyzed the effects induced by clementine ASP-RICH proteins (CcASP-RICH) when expressed in the tobacco heterologous system, focusing on the male gametophyte. The aim was to gain insight into the mechanism of action of ASP-RICH in a well-known cellular system, i.e., the pollen tube. Pollen tubes of tobacco transgenic lines expressing CcASP-RICH were analyzed for Ca2+ distribution, ROS, proton gradient, as well as cytoskeleton and cell wall. CcASP-RICH modulated Ca2+ content and consequently affected cytoskeleton organization and the deposition of cell wall components. In turn, this affected the growth pattern of pollen tubes. Although the expression of CcASP-RICH did not exert a remarkable effect on the growth rate of pollen tubes, effects at the level of growth pattern suggest that the expression of ASP-RICH may exert a regulatory action on the mechanism of plant cell growth.


Asunto(s)
Citrus , Tubo Polínico , Pared Celular/metabolismo , Citoesqueleto/metabolismo , Polinización , Nicotiana/genética
7.
Nutr Metab Cardiovasc Dis ; 31(5): 1542-1547, 2021 05 06.
Artículo en Inglés | MEDLINE | ID: mdl-33810964

RESUMEN

BACKGROUND AND AIMS: Novel genetic determinants associated with coronary artery disease (CAD) have been discovered by genome wide association studies. Variants encompassing the CELSR2- PSRC1-SORT1 gene cluster have been associated with CAD. This study is aimed to investigate the rs629301 polymorphism association with the extent of CAD evaluated by coronary angiography (CAG), and to evaluate its associations with an extensive panel of lipid and lipoprotein measurements in a large Italian cohort of 2429 patients. METHODS AND RESULTS: The patients were collected by four Intensive Care Units located in Palermo and Verona (Italy). Clinical Records were filed, blood samples were collected, lipids and apolipoproteins (apo) were measured in separate laboratories. CAD was defined by the presence of stenotic arteries (>50% lumen diameter) by CAG. The presence of CAD was associated with the rs629301 genotype. Patients with CAD were 78% and 73% (p = 0.007) of the T/T vs. T/G + G/G genotype carriers respectively. T/T genotype was also correlated with the number of stenotic arteries, with a 1.29 (1.04-1.61) risk to have a three-arteries disease. T/T genotype correlated with higher levels of LDL-, non-HDL cholesterol, apoB, apoE and apoCIII, and lower HDL-cholesterol. Logistic Regression confirmed that rs629301was associated with CAD independently from the common risk factors, with a risk similar to that conferred by ten years of age [odds ratios were 1.43 (1.04-1.96) and 1.39 (1.22-1.58) respectively]. CONCLUSIONS: rs629301 risk allele was independently associated with the extension and severity of CAD and positively with apoE and apoB containing lipoproteins.


Asunto(s)
Cadherinas/genética , Angiografía Coronaria , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/genética , Polimorfismo de Nucleótido Simple , Factores de Edad , Anciano , Biomarcadores/sangre , Estenosis Coronaria/sangre , Estenosis Coronaria/epidemiología , Femenino , Estudios de Asociación Genética , Predisposición Genética a la Enfermedad , Humanos , Italia/epidemiología , Lípidos/sangre , Masculino , Persona de Mediana Edad , Fenotipo , Valor Predictivo de las Pruebas , Pronóstico , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo
8.
Sensors (Basel) ; 21(18)2021 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-34577514

RESUMEN

The orientation of a magneto-inertial measurement unit can be estimated using a sensor fusion algorithm (SFA). However, orientation accuracy is greatly affected by the choice of the SFA parameter values which represents one of the most critical steps. A commonly adopted approach is to fine-tune parameter values to minimize the difference between estimated and true orientation. However, this can only be implemented within the laboratory setting by requiring the use of a concurrent gold-standard technology. To overcome this limitation, a Rigid-Constraint Method (RCM) was proposed to estimate suboptimal parameter values without relying on any orientation reference. The RCM method effectiveness was successfully tested on a single-parameter SFA, with an average error increase with respect to the optimal of 1.5 deg. In this work, the applicability of the RCM was evaluated on 10 popular SFAs with multiple parameters under different experimental scenarios. The average residual between the optimal and suboptimal errors amounted to 0.6 deg with a maximum of 3.7 deg. These encouraging results suggest the possibility to properly tune a generic SFA on different scenarios without using any reference. The synchronized dataset also including the optical data and the SFA codes are available online.


Asunto(s)
Algoritmos , Heurística , Fenómenos Biomecánicos , Fenómenos Magnéticos , Magnetismo
9.
Sensors (Basel) ; 21(7)2021 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-33916432

RESUMEN

The orientation of a magneto and inertial measurement unit (MIMU) is estimated by means of sensor fusion algorithms (SFAs) thus enabling human motion tracking. However, despite several SFAs implementations proposed over the last decades, there is still a lack of consensus about the best performing SFAs and their accuracy. As suggested by recent literature, the filter parameters play a central role in determining the orientation errors. The aim of this work is to analyze the accuracy of ten SFAs while running under the best possible conditions (i.e., their parameter values are set using the orientation reference) in nine experimental scenarios including three rotation rates and three commercial products. The main finding is that parameter values must be specific for each SFA according to the experimental scenario to avoid errors comparable to those obtained when the default parameter values are used. Overall, when optimally tuned, no statistically significant differences are observed among the different SFAs in all tested experimental scenarios and the absolute errors are included between 3.8 deg and 7.1 deg. Increasing the rotation rate generally leads to a significant performance worsening. Errors are also influenced by the MIMU commercial model. SFA MATLAB implementations have been made available online.

10.
Int J Mol Sci ; 22(2)2021 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-33477297

RESUMEN

Mal secco is one of the most severe diseases of citrus, caused by the necrotrophic fungus Plenodomus tracheiphilus. With the main aim of identifying candidate genes involved in the response of citrus plants to "Mal secco", we performed a de novo transcriptome analysis of rough lemon seedlings subjected to inoculation of P. tracheiphilus. The analysis of differential expressed genes (DEGs) highlighted a sharp response triggered by the pathogen as a total of 4986 significant DEGs (2865 genes up-regulated and 2121 down-regulated) have been revealed. The analysis of the most significantly enriched KEGG pathways indicated that a crucial role is played by genes involved in "Plant hormone signal transduction", "Phenylpropanoid biosynthesis", and "Carbon metabolism". The main findings of this work are that under fungus challenge, the rough lemon genes involved both in the light harvesting and the photosynthetic electron flow were significantly down-regulated, thus probably inducing a shortage of energy for cellular functions. Moreover, the systemic acquired resistance (SAR) was activated through the induced salicylic acid cascade. Interestingly, RPM1 interacting protein 4, an essential positive regulator of plant defense, and BIR2, which is a negative regulator of basal level of immunity, have been identified thus representing useful targets for molecular breeding.


Asunto(s)
Ascomicetos/genética , Citrus/genética , Perfilación de la Expresión Génica/métodos , Micosis/genética , Fotosíntesis , Enfermedades de las Plantas/microbiología , Reguladores del Crecimiento de las Plantas/metabolismo , Hojas de la Planta/metabolismo , Proteínas de Plantas/metabolismo , Plantones/metabolismo , Transcriptoma
12.
Ital J Pediatr ; 50(1): 19, 2024 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-38273404

RESUMEN

BACKGROUND: Diagnosis of acute otitis media (AOM) in children can be challenging, given that symptoms are often non-specific or absent, and that the direct observation of the tympanic membrane in its entirety through otoscopy can sometimes be difficult. The aim of this study is to assess the diagnostic concordance in detection of AOM episodes between primary care paediatricians and physicians especially trained in paediatric otoscopy, and to characterize the most misleading elements in diagnostic failure. METHODS: Consecutive clinical charts of children regularly followed for recurrent AOM (RAOM, i.e.: >3 episodes in 6 months or > 4 episodes in 1 year) at our Otitis Media paediatric outpatient clinic were retrospectively screened, in order to collect any diagnosis of AOM episode (and the related clinical findings/middle ear complaints) performed by primary care paediatricians/emergency room paediatricians. Diagnosis of AOM episode was validated by the same experienced physician (FF) in case of otoscopic relief of a bulging eardrum with at least one of the following: hyperaemia or yellow-like colour. The diagnostic concordance in detection of AOM episodes between primary care/emergency room paediatricians and our internal validator was expressed as the percentage of matching diagnosis. RESULTS: One hundred and thirty-four single AOM episodes occurring in 87 children (mean age: 26.9 +/- 18.9 months) were included in the analysis. Diagnostic concordance in detection of AOM episodes between primary care/emergency room paediatricians and our internal validator was reported in 72.4% of cases. The most common pitfall found in our study was the misleading diagnosis of AOM in case of hyperaemic tympanic membrane without bulging (32/37 out of non-validated diagnoses). CONCLUSIONS: AOM diagnosis still represents a relevant issue among paediatricians in our country, and the presence of tympanic membrane hyperaemia without concomitant bulging can be confusing.


Asunto(s)
Hiperemia , Otitis Media , Niño , Humanos , Lactante , Preescolar , Estudios Retrospectivos , Otitis Media/diagnóstico , Otoscopía , Enfermedad Crónica , Enfermedad Aguda
13.
Materials (Basel) ; 17(10)2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38793421

RESUMEN

A central debate is the improvement in the mechanical and water resistance of sustainable earthen architecture without additives or stabilizers. This innovative work aims to test the effects of a graphene-based additive, optimized for the improvement in concrete properties, on the strength and water resistance of raw-earth plasters without any stabilizer other than sand. Given the heterogeneous nature of raw earth, three different soils were tested by adding three increasing graphene-based additive contents (0.01, 0.05 and 0.1 wt% of the earth-sand proportion). The link between soil intrinsic properties, i.e., geotechnical and mineralogical properties, and their interaction with the additive were investigated through geotechnical characterization, as well as mineralogical characterization, by XRD and ATR-FTIR analyses. The experimental tests carried out focused on the adhesion properties of the twelve different plasters on standard hollow bricks and on their interaction with water through capillary rise tests and erosion resistance tests. Conclusion from the experimental tests suggests that the graphene-based additive in earth plasters, by increasing the cohesion of the mixture, improves their adhesion performance.

14.
JMIR Form Res ; 8: e50035, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38691395

RESUMEN

BACKGROUND: Wrist-worn inertial sensors are used in digital health for evaluating mobility in real-world environments. Preceding the estimation of spatiotemporal gait parameters within long-term recordings, gait detection is an important step to identify regions of interest where gait occurs, which requires robust algorithms due to the complexity of arm movements. While algorithms exist for other sensor positions, a comparative validation of algorithms applied to the wrist position on real-world data sets across different disease populations is missing. Furthermore, gait detection performance differences between the wrist and lower back position have not yet been explored but could yield valuable information regarding sensor position choice in clinical studies. OBJECTIVE: The aim of this study was to validate gait sequence (GS) detection algorithms developed for the wrist position against reference data acquired in a real-world context. In addition, this study aimed to compare the performance of algorithms applied to the wrist position to those applied to lower back-worn inertial sensors. METHODS: Participants with Parkinson disease, multiple sclerosis, proximal femoral fracture (hip fracture recovery), chronic obstructive pulmonary disease, and congestive heart failure and healthy older adults (N=83) were monitored for 2.5 hours in the real-world using inertial sensors on the wrist, lower back, and feet including pressure insoles and infrared distance sensors as reference. In total, 10 algorithms for wrist-based gait detection were validated against a multisensor reference system and compared to gait detection performance using lower back-worn inertial sensors. RESULTS: The best-performing GS detection algorithm for the wrist showed a mean (per disease group) sensitivity ranging between 0.55 (SD 0.29) and 0.81 (SD 0.09) and a mean (per disease group) specificity ranging between 0.95 (SD 0.06) and 0.98 (SD 0.02). The mean relative absolute error of estimated walking time ranged between 8.9% (SD 7.1%) and 32.7% (SD 19.2%) per disease group for this algorithm as compared to the reference system. Gait detection performance from the best algorithm applied to the wrist inertial sensors was lower than for the best algorithms applied to the lower back, which yielded mean sensitivity between 0.71 (SD 0.12) and 0.91 (SD 0.04), mean specificity between 0.96 (SD 0.03) and 0.99 (SD 0.01), and a mean relative absolute error of estimated walking time between 6.3% (SD 5.4%) and 23.5% (SD 13%). Performance was lower in disease groups with major gait impairments (eg, patients recovering from hip fracture) and for patients using bilateral walking aids. CONCLUSIONS: Algorithms applied to the wrist position can detect GSs with high performance in real-world environments. Those periods of interest in real-world recordings can facilitate gait parameter extraction and allow the quantification of gait duration distribution in everyday life. Our findings allow taking informed decisions on alternative positions for gait recording in clinical studies and public health. TRIAL REGISTRATION: ISRCTN Registry 12246987; https://www.isrctn.com/ISRCTN12246987. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.1136/bmjopen-2021-050785.

15.
Sci Rep ; 14(1): 1754, 2024 01 19.
Artículo en Inglés | MEDLINE | ID: mdl-38243008

RESUMEN

This study aimed to validate a wearable device's walking speed estimation pipeline, considering complexity, speed, and walking bout duration. The goal was to provide recommendations on the use of wearable devices for real-world mobility analysis. Participants with Parkinson's Disease, Multiple Sclerosis, Proximal Femoral Fracture, Chronic Obstructive Pulmonary Disease, Congestive Heart Failure, and healthy older adults (n = 97) were monitored in the laboratory and the real-world (2.5 h), using a lower back wearable device. Two walking speed estimation pipelines were validated across 4408/1298 (2.5 h/laboratory) detected walking bouts, compared to 4620/1365 bouts detected by a multi-sensor reference system. In the laboratory, the mean absolute error (MAE) and mean relative error (MRE) for walking speed estimation ranged from 0.06 to 0.12 m/s and - 2.1 to 14.4%, with ICCs (Intraclass correlation coefficients) between good (0.79) and excellent (0.91). Real-world MAE ranged from 0.09 to 0.13, MARE from 1.3 to 22.7%, with ICCs indicating moderate (0.57) to good (0.88) agreement. Lower errors were observed for cohorts without major gait impairments, less complex tasks, and longer walking bouts. The analytical pipelines demonstrated moderate to good accuracy in estimating walking speed. Accuracy depended on confounding factors, emphasizing the need for robust technical validation before clinical application.Trial registration: ISRCTN - 12246987.


Asunto(s)
Velocidad al Caminar , Dispositivos Electrónicos Vestibles , Humanos , Anciano , Marcha , Caminata , Proyectos de Investigación
16.
Cytokine ; 61(1): 218-22, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23089051

RESUMEN

Polymorphisms of genes encoding key factors for the control and activation of inflammatory response and coagulation cascade regulation may play a role in genetic susceptibility to acute myocardial infarction (AMI). This study sought to analyze the effect of TNF -308G/A and pro-thrombin (FII) 20210G/A polymorphisms on the laboratory parameters of young patients affected by AMI. Results indicated that TNF -308A positive genotype frequencies were increased in these patients and that a genetically determined higher production of TNF-α is associated in young subjects to a more severe cardiac damage as depicted by higher levels of troponin, Creatine kinase-MB Isoenzyme (mCK-MB) and a significant increased plasma fibrinogen levels. Similar and probably additive effects on might have a genetically determined increased production of pro-thrombin even if no significant differences in genotype frequencies of pro-thrombin (FII) 20210G/A polymorphisms were observed in this study. All together these results, indicating the relationship among genetically determined TNFα and FII production and increased levels of tissue damage markers of AMI, suggest that a complex genetic background, might be involved in susceptibility to AMI in young men influencing the extension and severity of the disease.


Asunto(s)
Infarto del Miocardio/genética , Protrombina/genética , Factor de Necrosis Tumoral alfa/genética , Adulto , Factores de Edad , Biomarcadores/sangre , Forma MB de la Creatina-Quinasa/biosíntesis , Fibrinógeno/biosíntesis , Frecuencia de los Genes , Predisposición Genética a la Enfermedad , Genotipo , Humanos , Inflamación/genética , Masculino , Persona de Mediana Edad , Infarto del Miocardio/metabolismo , Polimorfismo de Nucleótido Simple , Troponina/biosíntesis , Troponina/genética , Factor de Necrosis Tumoral alfa/biosíntesis , Adulto Joven
17.
Curr Atheroscler Rep ; 15(6): 329, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23591672

RESUMEN

Atherosclerosis (AS) is a chronic, progressive, multifactorial disease mostly affecting large and medium-sized elastic and muscular arteries. It has formerly been considered a bland lipid storage disease. Currently, multiple independent pathways of evidence suggest this pathological condition is a peculiar form of inflammation, triggered by cholesterol-rich lipoproteins and influenced both by environmental and genetic factors. The Human Genome Project opened up the opportunity to dissect complex human traits and to understand basic pathways of multifactorial diseases such as AS. Population-based association studies have emerged as powerful tools for examining genes with a role in common multifactorial diseases that have a strong environmental component. These association studies often estimate the risk of developing a certain disease in carriers and non-carriers of a particular genetic polymorphism. Dissecting out the influence of pro-inflammatory genes within the complex pathophysiology of AS and its complications will help to provide a more complete risk assessment and complement known classical cardiovascular risk factors. The detection of a risk profile will potentially allow both the early identification of individuals susceptible to disease and the possible discovery of potential targets for drug or lifestyle modification; i.e. it will open the door to personalized medicine.


Asunto(s)
Enfermedad de la Arteria Coronaria/genética , Inflamación/genética , Aterosclerosis/complicaciones , Aterosclerosis/genética , Aterosclerosis/inmunología , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/inmunología , Marcadores Genéticos , Predisposición Genética a la Enfermedad , Estudio de Asociación del Genoma Completo , Humanos , Inflamación/complicaciones , Mediadores de Inflamación/metabolismo , Polimorfismo Genético , Polimorfismo de Nucleótido Simple , Medicina de Precisión
18.
Sci Data ; 10(1): 38, 2023 01 19.
Artículo en Inglés | MEDLINE | ID: mdl-36658136

RESUMEN

Wearable devices are used in movement analysis and physical activity research to extract clinically relevant information about an individual's mobility. Still, heterogeneity in protocols, sensor characteristics, data formats, and gold standards represent a barrier for data sharing, reproducibility, and external validation. In this study, we aim at providing an example of how movement data (from the real-world and the laboratory) recorded from different wearables and gold standard technologies can be organized, integrated, and stored. We leveraged on our experience from a large multi-centric study (Mobilise-D) to provide guidelines that can prove useful to access, understand, and re-use the data that will be made available from the study. These guidelines highlight the encountered challenges and the adopted solutions with the final aim of supporting standardization and integration of data in other studies and, in turn, to increase and facilitate comparison of data recorded in the scientific community. We also provide samples of standardized data, so that both the structure of the data and the procedure can be easily understood and reproduced.

19.
Front Cardiovasc Med ; 10: 1326091, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38299080

RESUMEN

Introduction: The use of contemporary drug-eluting stents (DES) has significantly improved outcomes of patients with coronary artery disease (CAD) undergoing percutaneous coronary intervention (PCI). However, concerns exist regarding the long-term proinflammatory effects of durable polymer coatings used in most DES, potentially leading to long-term adverse events. First-generation polymer-free stent technologies, such as sirolimus- and probucol-eluting stents (PF-SES), have shown an excellent safety and efficacy profile. The aim of this study was to evaluate the safety and efficacy of the new ultrathin Coroflex ISAR NEO PF-SES, in a more-comers PCI population. Methods: The CAESAR (a more-Comers populAtion trEated with an ultrathin struts polimer-free Sirolimus stent: An Italian post-maRketing study) registry is a multicenter, prospective study conducted in Italy, enrolling more-comers CAD patients undergoing PCI with the Coroflex ISAR NEO stent. Patients with left main (LM) disease, cardiogenic shock (CS), or severely reduced left-ventricular ejection fraction (LVEF) were excluded. The primary endpoint was target-lesion revascularization (TLR) at 1 year. Results: A total of 425 patients were enrolled at 13 centers (mean age 66.9 ± 11.6 years, Diabetes mellitus 29%, acute coronary syndrome 67%, chronic total occlusion 9%). Of these, 40.9% had multivessel disease (MVD) and in 3.3% cases, the target lesion was in-stent restenosis (ISR). Clinical device success was reached in 422 (99.6%) cases. At 1 year, only two (0.5%) subjects presented ischemia-driven TLR. The 1-year rates of target vessel revascularization and MACE were 0.5% and 5.1%, respectively. Major bleeding was observed in four (1.0%) patients. Conclusion: In this multicenter, prospective registry, the use of a new ultrathin Coroflex ISAR NEO PF-SES in a more-comers PCI population showed good safety and efficacy at 1 year.

20.
EuroIntervention ; 18(13): e1108-e1119, 2023 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-36043326

RESUMEN

BACKGROUND: Data on left main (LM) percutaneous coronary interventions (PCI) have mostly been obtained in studies using drug-eluting stent (DES) platforms without dedicated large-vessel devices and with limited expansion capability. AIMS: Our study aimed to investigate the safety and efficacy of LM PCI with the latest-generation Resolute Onyx DES. METHODS: ROLEX (Revascularization Of LEft main with resolute onyX) is a prospective, multicentre study (ClinicalTrials.gov: NCT03316833) enrolling patients with unprotected LM coronary artery disease and a SYNTAX score <33 undergoing PCI with the Resolute Onyx zotarolimus-eluting coronary stent, that includes dedicated extra-large vessel platforms. The primary endpoint (EP) was target lesion failure (TLF): a composite of cardiac death, target vessel myocardial infarction (TVMI) and ischaemia-driven target lesion revascularisation (ID-TLR), at 1 year. All events were adjudicated by an independent clinical event committee. An independent core lab analysed all procedural angiograms. RESULTS: A total of 450 patients (mean age 71.8 years, SYNTAX score 24.5±7.2, acute coronary syndrome in 53%) were enrolled in 26 centres. Of these, 77% of subjects underwent PCI with a single-stent and 23% with a 2-stent technique (8% double kissing [DK] crush, 6% culotte, 9% T/T and small protrusion [TAP] stenting). Intravascular imaging guidance was used in 45% (42% intravascular ultrasound [IVUS], 3% optical coherence tomography [OCT]). At 1 year, the primary EP incidence was 5.1% (cardiac death 2.7%, TVMI 2.7%, ID-TLR 2.0%). The definite/probable stent thrombosis rate was 1.1%. In a prespecified adjusted subanalysis, the primary EP incidence was significantly lower in patients undergoing IVUS/OCT-guided versus angio-guided PCI (2.0 vs 7.6%; hazard ratio [HR] 0.28, 95% confidence interval [CI]: 0.13-0.58; p<0.001). CONCLUSIONS: In this large, multicentre, prospective registry, LM PCI with the Resolute Onyx DES showed good safety and efficacy at 1 year, particularly when guided by intracoronary imaging.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Anciano , Intervención Coronaria Percutánea/efectos adversos , Stents Liberadores de Fármacos/efectos adversos , Resultado del Tratamiento , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Infarto del Miocardio/etiología , Stents/efectos adversos , Angiografía/efectos adversos , Angiografía Coronaria/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA