Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Sports Med Phys Fitness ; 64(7): 631-639, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38916086

RESUMEN

BACKGROUND: During a prolonged quarantine, there is a need to monitor aerobic fitness levels of trained individuals who are isolated with a simple fitness test that can be performed in confined space of their own homes. This study examined the reliability, validity, usefulness and sensitivity of a novel 3-min submaximal heart rate burpees test (or SubHR3-MBT) to assess and monitor changes in aerobic fitness, of trained athletes. In the SubHR3-MBT, male and female athletes performed 48 and 39 burpees respectively, within 3 min by following a constant beeping pace. The performance criterion of the SubHR3-MBT is the highest heart rate attained (or exercise HRpeak) at the end of 3-min (wherein a lower exercise HRpeak indicates a higher level of aerobic fitness). METHODS: A total of 40 male and female national athletes from various sports volunteered for the study. RESULTS: For reliability (Part 1), the SubHR3-MBT showed good relative and excellent reliability, with intraclass correlation coefficient 0.90 and coefficient of variation 2.6%, respectively. For validity (Part II), there was significant negative correlation between relative exercise HRpeak with respiratory gas-measured VO2max (r=-0.51, large; P<0.001). The test's technical error of measurement of 2.3 is slightly greater than its smallest worthwhile change of 1.5. For sensitivity (Part III), the athletes were tested twice for their SubHR3-MBT and VO2max, once at baseline and another at a followed-up test after >10 weeks. There was a significant correlation between the % change in relative exercise HRpeak with the % change in VO2max (r=-0.66, large; P<0.001). CONCLUSIONS: The SubHR3-MBT is a reliable, valid, marginally useful test and may be able to track changes in aerobic fitness in trained athletes with moderate levels of sensitivity, in case of future isolation due to pandemic occurrence.


Asunto(s)
Prueba de Esfuerzo , Frecuencia Cardíaca , Humanos , Masculino , Femenino , Reproducibilidad de los Resultados , Prueba de Esfuerzo/métodos , Frecuencia Cardíaca/fisiología , Adulto , Aptitud Física/fisiología , Atletas , Adulto Joven , Sensibilidad y Especificidad , COVID-19
2.
Artículo en Inglés | MEDLINE | ID: mdl-35627465

RESUMEN

Due to a prolonged period of quarantine during the COVID-19 pandemic, it is essential to monitor the physical condition of athletes isolated at home with a fitness tool that measures various aspects of physical fitness, which does not require any special equipment, and can be performed within a small space. This study assessed the reliability and validity of the test of performing the maximal number of burpees in 3 min (or 3-MBT) to monitor strength, power, and aerobic endurance in trained athletes. For Part I (reliability of the 3-MBT), 20 (10 male, 10 female) national athletes from various sports performed the 3-MBT on two separate test sessions. Athletes performed as many burpees as possible within 3 min and the primary performance criteria was the number of burpees completed (where a higher number reflected a better performance). The 3-MBT displayed excellent relative reliability in the athletes, with an intraclass correlation coefficient (ICC) and coefficient of variation (CV %) of >0.92, and <3.0%, respectively. For Part II (validity of the 3-MBT), 40 (20 M, 20 F) athletes performed the 3-MBT, and the countermovement jump (CMJ), isometric mid-thigh pull (IMTP), seated medicine ball throw (SMBT), isometric bench (IBP) and maximal aerobic power (VO2max) tests on separate sessions. When data of male and female athletes were pooled, there were significant correlations between relative 3-MBT and relative CMJ height (r = 0.65, large; p < 0.001), relative IMPT peak force (r = 0.50, large; p < 0.001), relative IBP peak force (r = 0.36, moderate, p = 0.02), and relative VO2max (r = 0.50, large; p < 0.001). In conclusion, the 3-MBT is a reliable and reasonably useful test and is a valid assessment of lower body power and strength, upper body strength and aerobic fitness in trained male and female athletes.


Asunto(s)
COVID-19 , Fuerza Muscular , Atletas , Femenino , Humanos , Masculino , Pandemias , Aptitud Física , Reproducibilidad de los Resultados
3.
Arch Dermatol ; 142(5): 577-84, 2006 May.
Artículo en Inglés | MEDLINE | ID: mdl-16702495

RESUMEN

OBJECTIVES: To evaluate the usefulness of integrated positron emission tomography and computed tomography (PET/CT) in staging mycosis fungoides (MF) and Sézary syndrome and to correlate PET/CT data with histopathologic diagnosis of lymph nodes (LNs). DESIGN: A single-center, prospective cohort analysis. SETTING: Academic referral center for cutaneous lymphoma. PATIENTS: Thirteen patients with MF and SS at risk for secondary LN involvement. Interventions Patients were clinically evaluated based on general physical examination, total body skin examination, and laboratory screening. They underwent integrated PET/CT followed by excisional biopsy of LNs. MAIN OUTCOME MEASURES: We used PET/CT to assess LN size and metabolic activity. Enlarged LNs were defined as axillary or inguinal LNs with a short axis 1.5 cm or larger; or cervical LN, with a short axis 1.0 cm or larger. We classified LN pathologic results according to National Cancer Institute (LN1-4) and World Health Organization (WHO 1-3) criteria. We quantified PET activity using standardized uptake value (SUV) and correlated with LN grade. RESULTS: Based on CT size criteria alone, only 5 patients had enlarged LNs, whereas PET revealed hypermetabolic LNs in all 13 patients. Six patients had LN1-3, and 7 had effacement of LN architecture by lymphoma cells (LN4). Of the 7 patients with LN4 nodes, 4 had SS, and 3 had tumorous MF. Two patients with LN4 nodes had inguinal LNs smaller than 1.5 cm and would have been assigned an N0 classification without the use of integrated PET/CT. Correlation of SUV with LN grade revealed that LN1-3 nodes were associated with a mean SUV of 2.7 (median SUV, 2.2; range, 2.0-4.7) and LN4 nodes were associated with a mean SUV of 5.4 (median SUV, 3.9; range, 2.1-11.8). Patients with large cell transformation had the highest SUVs. CONCLUSIONS: For staging MF and SS, PET/CT was more sensitive in detecting LN involved by lymphoma compared with CT data alone and thus may provide more accurate staging and prognostic information. The intensity of PET activity correlated with histologic LN grade.


Asunto(s)
Micosis Fungoide/diagnóstico , Síndrome de Sézary/diagnóstico , Neoplasias Cutáneas/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Micosis Fungoide/diagnóstico por imagen , Micosis Fungoide/patología , Estadificación de Neoplasias/métodos , Proyectos Piloto , Tomografía de Emisión de Positrones , Valor Predictivo de las Pruebas , Estudios Prospectivos , Síndrome de Sézary/diagnóstico por imagen , Síndrome de Sézary/patología , Neoplasias Cutáneas/diagnóstico por imagen , Neoplasias Cutáneas/patología , Tomografía Computarizada por Rayos X
4.
Genome Res ; 15(2): 269-75, 2005 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-15687290

RESUMEN

Large-scale genetic studies are highly dependent on efficient and scalable multiplex SNP assays. In this study, we report the development of Molecular Inversion Probe technology with four-color, single array detection, applied to large-scale genotyping of up to 12,000 SNPs per reaction. While generating 38,429 SNP assays using this technology in a population of 30 trios from the Centre d'Etude Polymorphisme Humain family panel as part of the International HapMap project, we established SNP conversion rates of approximately 90% with concordance rates >99.6% and completeness levels >98% for assays multiplexed up to 12,000plex levels. Furthermore, these individual metrics can be "traded off" and, by sacrificing a small fraction of the conversion rate, the accuracy can be increased to very high levels. No loss of performance is seen when scaling from 6,000plex to 12,000plex assays, strongly validating the ability of the technology to suppress cross-reactivity at high multiplex levels. The results of this study demonstrate the suitability of this technology for comprehensive association studies that use targeted SNPs in indirect linkage disequilibrium studies or that directly screen for causative mutations.


Asunto(s)
Inversión Cromosómica/genética , Técnicas de Sonda Molecular/tendencias , Polimorfismo de Nucleótido Simple/genética , Inversión Cromosómica/estadística & datos numéricos , Análisis por Conglomerados , Sondas de ADN/genética , Perfilación de la Expresión Génica , Genoma Humano , Genotipo , Humanos , Técnicas de Sonda Molecular/normas , Técnicas de Sonda Molecular/estadística & datos numéricos , Sondas Moleculares/genética , Proyectos de Investigación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA