Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 34(2): 382-388, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36423239

RESUMEN

INTRODUCTION: Transseptal puncture (TSP) is routinely performed for left atrial ablation procedures. The use of a three-dimensional (3D) mapping system or intracardiac echocardiography (ICE) is useful in localizing the fossa ovalis and reducing fluoroscopy use. We aimed to compare the safety and efficacy between 3D mapping system-guided TSP and ICE-guided TSP techniques. METHODS: We conducted a prospective observational study of patients undergoing TSP for left atrial catheter ablation procedures (mostly atrial fibrillation ablation). Propensity scoring was used to match patients undergoing 3D-guided TSP with patients undergoing ICE-guided TSP. Logistic regression was used to compare the clinical data, procedural data, fluoroscopy time, success rate, and complications between the groups. RESULTS: Sixty-five patients underwent 3D-guided TSP, and 151 propensity score-matched patients underwent ICE-guided TSP. The TSP success rate was 100% in both the 3D-guided and ICE-guided groups. Median needle time was 4.00 min (interquartile range [IQR]: 2.57-5.08) in patients with 3D-guided TSP compared to 4.02 min (IQR: 2.83-6.95) in those with ICE-guided TSP (p = .22). Mean fluoroscopy time was 0.2 min (IQR: 0.1-0.4) in patients with 3D-guided TSP compared to 1.2 min (IQR: 0.7-2.2) in those with ICE-guided TSP (p < .001). There were no complications related to TSP in both group. CONCLUSIONS: Three-dimensional mapping-guided TSP is as safe and effective as ICE-guided TSP without additional cost.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Puntaje de Propensión , Atrios Cardíacos , Punciones , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Fluoroscopía , Resultado del Tratamiento
2.
J Cardiovasc Electrophysiol ; 33(8): 1714-1722, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35652836

RESUMEN

INTRODUCTION: Monitored anesthesia care (MAC) or general anesthesia (GA) can be used during catheter ablation (CA) of atrial fibrillation (AF). However, each approach may have advantages and disadvantages with variability in operator preferences. The optimal approach has not been well established. The purpose of this study was to compare procedural efficacy, safety, clinical outcomes, and cost of CA for AF performed with MAC versus GA. METHODS: The study population consisted of 810 consecutive patients (mean age: 63 ± 10 years, paroxysmal AF: 48%) who underwent a first CA for AF. All patients completed a preprocedural evaluation by the anesthesiologists. Among the 810 patients, MAC was used in 534 (66%) and GA in 276 (34%). Ten patients (1.5%) had to convert to GA during the CA. RESULTS: Although the total anesthesia care was longer with GA particularly in patients with persistent AF, CA was shorter by 5 min with GA than MAC (p < 0.01). Prevalence of perioperative complications was similar between the two groups (4% vs. 4%, p = 0.89). There was no atrioesophageal fistula with either approach. GA was associated with a small, ~7% increase in total charges due to longer anesthesia care. During 43 ± 17 months of follow-up after a single ablation procedure, 271/534 patients (51%) in the MAC and 129/276 (47%) patients in the GA groups were in sinus rhythm without concomitant antiarrhythmic drug therapy (p = 0.28). CONCLUSION: With the participation of an anesthesiologist, and proper preoperative assessment, CA of AF using GA or MAC has similar efficacy and safety.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Anciano , Anestesia General/efectos adversos , Antiarrítmicos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Humanos , Persona de Mediana Edad , Resultado del Tratamiento
3.
Europace ; 24(7): 1119-1126, 2022 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-35025987

RESUMEN

AIMS: There is limited information on what clinical factors are associated with the development of pericardial effusion after leadless pacemaker implantation. We sought to determine predictors of and to develop a risk score for pericardial effusion in patients undergoing Micra leadless pacemaker implantation attempt. METHODS AND RESULTS: Patients (n = 2817) undergoing implant attempt from the Micra global trials were analysed. Characteristics were compared between patients with and without pericardial effusion (including cardiac perforation and tamponade). A risk score for pericardial effusion was developed from 18 pre-procedural clinical variables using lasso logistic regression. Internal validation and future prediction performance were estimated using bootstrap resampling. The scoring system was also externally validated using data from the Micra Acute Performance European and Middle East (MAP EMEA) registry. There were 32 patients with a pericardial effusion [1.1%, 95% confidence interval (CI): 0.8-1.6%]. Following lasso logistic regression, 11 of 18 variables remained in the model from which point values were assigned. The C-index was 0.79 (95% CI: 0.71-0.88). Patient risk score profile ranged from -4 (lowest risk) to 5 (highest risk) with 71.8% patients considered low risk (risk score ≤0), 16.6% considered medium risk (risk score = 1), and 11.7% considered high risk (risk score ≥2) for effusion. The median C-index following bootstrap validation was 0.73 (interquartile range: 0.70-0.75). The C-index based on 9 pericardial effusions from the 928 patients in the MAP EMEA registry was 0.68 (95% CI: 0.52-0.83). The pericardial effusion rate increased significantly with additional Micra deployments in medium-risk (P = 0.034) and high-risk (P < 0.001) patients. CONCLUSION: The overall rate of pericardial effusion following Micra implantation attempt is 1.1% and has decreased over time. The risk of pericardial effusion after Micra implant attempt can be predicted using pre-procedural clinical characteristics with reasonable discrimination. CLINICAL TRIAL REGISTRATION: The Micra Post-Approval Registry (ClinicalTrials.gov identifier: NCT02536118), Micra Continued Access Study (ClinicalTrials.gov identifier: NCT02488681), and Micra Transcatheter Pacing Study (ClinicalTrials.gov identifier: NCT02004873).


Asunto(s)
Marcapaso Artificial , Derrame Pericárdico , Ensayos Clínicos como Asunto , Diseño de Equipo , Humanos , Marcapaso Artificial/efectos adversos , Derrame Pericárdico/diagnóstico , Derrame Pericárdico/epidemiología , Derrame Pericárdico/etiología , Estudios Prospectivos , Factores de Riesgo , Resultado del Tratamiento
4.
J Cardiovasc Electrophysiol ; 32(12): 3173-3178, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34586686

RESUMEN

INTRODUCTION: Quinidine is an effective therapy for a subset of polymorphic ventricular tachycardia and ventricular fibrillation (VF) syndromes; however, the efficacy of quinidine in scar-related monomorphic ventricular tachycardia (MMVT) is unclear. METHODS AND RESULTS: Between 2009 and 2020 a single VT referral center, a total of 23 patients with MMVT and structural heart disease (age 66.7 ± 10.9, 20 males, 15 with ischemic cardiomyopathy, mean LVEF 22.2 ± 12.3%, 9 with left ventricular assist device [LVAD]) were treated with quinidine (14 quinidine gluconate; 996 ± 321 mg, 8 quinidine sulfate; 1062 ± 588 mg). Quinidine was used in combination with other antiarrhythmics (AAD) in 19 (13 also on amiodarone). All patients previously failed >1 AAD (amiodarone 100%, mexiletine 73%, sotalol 32%, other 32%) and eight had prior ablations (median of 1.5). Quinidine was initiated in the setting of VT storm despite AADs (6), inability to tolerate other AADs (4), or recurrent VT(12). Ventricular arrhythmias recurred despite quinidine in 13 (59%) patients at a median of 26 (4-240) days after quinidine initiation. In patients with recurrent MMVT, VT cycle length increased from 359 to 434 ms (p = .02). Six (27.3%) patients remained on quinidine at 1 year with recurrence of ventricular arrhythmias in all. The following adverse effects were seen: gastrointestinal side effects (6), QT prolongation (2), rash (1), thrombocytopenia (1), neurologic side effects (1). One patient discontinued due to cost. CONCLUSION: Quinidine therapy has limited tolerability and long-term efficacy when used in the management of amiodarone-refractory scar-related MMVT.


Asunto(s)
Quinidina , Taquicardia Ventricular , Antiarrítmicos/efectos adversos , Humanos , Masculino , Quinidina/efectos adversos , Terapia Recuperativa , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/tratamiento farmacológico , Fibrilación Ventricular
5.
J Cardiovasc Electrophysiol ; 32(4): 1124-1128, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33625785

RESUMEN

BACKGROUND: Lead damage is a complication caused by lead manipulation or heating damage from conventional electrocautery (EC) after cardiovascular implantable electronic device (CIED) replacement. Application of electrical plasma (PEAK PlasmaBlade) is a new technology that reportedly reduces this risk. OBJECTIVES: This study was designed to compare the effect of EC versus PEAK PlasmaBlade on lead parameters and complications after generator replacement procedures. METHODS: We retrospectively studied 410 consecutive patients (840 leads) who underwent CIED replacement using EC (EC group) and 410 consecutive patients (824 leads) using PEAK PlasmaBlade (PlamaBlade group). Pacing lead impedance, incidence of lead damage, and complications were compared between both groups. RESULTS: Lead impedance increased in 393 leads (46.8%) in the EC group versus 282 leads (34.2%) in the PlasmaBlade group (p < .01) with average percent changes of 6.7% and 4.0% (p < .01), respectively. Lead impedance decreased in 438 leads (52.1%) in the EC group versus 507 leads (61.5%) in the PlasmaBlade group (p < .01) with average percent changes of -5.7% and -7.1% (p < .01), respectively. Lead damage requiring lead revision occurred in five leads (0.6%) or after five procedures (1.2%) in the EC group compared to three leads (0.4%, p = .50) or after three procedures (0.7%, p = .48) in the PlasmaBlade group. There were no significant differences in the procedural-related complications between the EC group (nine patients, 2.2%) and the PlasmaBlade group (five patients, 1.2%, p = .28). CONCLUSION: Conventional electrocautery can potentially damage lead insulations. However, this study shows that when used carefully electrocautery is as safe as the PEAK PlasmaBlade™.


Asunto(s)
Desfibriladores Implantables , Electrocoagulación , Desfibriladores Implantables/efectos adversos , Electrocoagulación/efectos adversos , Humanos , Prótesis e Implantes , Reoperación , Estudios Retrospectivos
6.
J Cardiovasc Electrophysiol ; 32(5): 1232-1239, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33600005

RESUMEN

BACKGROUND: Diabetes mellitus (DM) is a risk factor for atrial fibrillation (AF). The effect of antidiabetic medications on AF or the outcomes of catheter ablation (CA) has not been well described. We sought to determine whether metformin treatment is associated with a lower risk of atrial arrhythmias after CA in patients with DM and AF. METHODS AND RESULTS: A first CA was performed in 271 consecutive patients with DM and AF (age: 65 ± 9 years, women: 34%; and paroxysmal AF: 51%). At a median of 13 months after CA (interquartile range: 6-30), 100/182 patients (55%) treated with metformin remained in sinus rhythm without antiarrhythmic drug therapy, compared with 36/89 patients (40%) not receiving metformin (p = .03). There was a significant association between metformin therapy and freedom from recurrent atrial arrhythmias after CA in multivariable Cox hazards models (hazard ratio [HR]: 0.66; ±95% confidence interval [CI]: 0.44-0.98; p = .04) that adjusted for age, sex, body mass index, AF type (paroxysmal vs. nonparoxysmal), antiarrhythmic medication, obstructive sleep apnea, chronic kidney disease, coronary artery disease, left ventricular ejection fraction, and left atrial diameter. A Cox model that also incorporated other antidiabetic agents and fasting blood glucose demonstrated a similar reduction in the risk of recurrent atrial arrhythmias with metformin treatment (HR: 0.63; ±95% CI: 0.42-0.96; p = .03). CONCLUSIONS: In patients with DM, treatment with metformin appears to be independently associated with a significant reduction in the risk of recurrent atrial arrhythmias after CA for AF. Whether this effect is due to glycemic control or pleiotropic effects on electroanatomical mechanisms of AF remains to be determined.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Metformina , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Femenino , Humanos , Metformina/efectos adversos , Persona de Mediana Edad , Recurrencia , Factores de Riesgo , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
7.
Pacing Clin Electrophysiol ; 43(8): 775-780, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32525592

RESUMEN

BACKGROUND: Implanted defibrillators are capable of recording activity data based on company-specific proprietary algorithms. This study aimed to determine the prognostic significance of baseline and decline in device-derived activity level across different device companies in the real world. METHODS: We performed a retrospective cohort study of patients (n = 280) who underwent a defibrillator implantation (Boston, Medtronic, St. Jude, and Biotronik) for primary prevention at the University of Michigan from 2014 to 2016. Graphical data obtained from device interrogations were retrospectively converted to numerical data. The activity level averaged over a month from a week postimplantation was used as baseline. Subsequent weekly average activity levels (SALs) were standardized to this baseline. SAL below 59.4% was used as a threshold to group patients. All-cause mortality and death/heart failure were the primary end-points of this study. RESULTS: Fifty-six patients died in this study. On average, they experienced a 50% decline in SAL prior to death. Patients (n = 129) who dropped their SAL below threshold were more likely to be older, male, diabetic, and have more symptomatic heart failure. They also had a significantly increased risk of heart failure/death (hazard ratio [HR] 3.6, 95% confidence interval [95% CI] 2.3-5.8, P < .0001) or death (HR 4.2, 95% CI 2.2-7.7, P < .0001) compared to those who had sustained activity levels. Lower baseline activity level was also associated with significantly increased risk of heart failure/death and death. CONCLUSION: Significant decline in device-derived activity level and low baseline activity level are associated with increased mortality and heart failure in patients with an ICD for primary prevention.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/mortalidad , Prevención Primaria , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Factores de Riesgo
8.
J Nucl Cardiol ; 26(2): 417-427, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-28687967

RESUMEN

BACKGROUND: Ischemia contributes to arrhythmogenesis though its role is incompletely understood. Abnormal myocardial perfusion measured by PET imaging may predict ventricular arrhythmias (VAs) in a high-risk population. METHODS: Patients with implantable cardiac defibrillators who had undergone rubidium-82 cardiac PET imaging were identified. Patients were stratified by median MBF and MFR values for analysis. The Cox proportional hazards model was used to assess the impact of myocardial perfusion on survival free of VT independent of critical covariates. RESULTS: A total of 159 patients (124 (78%) males, median age 65.9 years, IQR [56.76-72.63]) were followed for 1.43 years IQR [0.83-2.21]. VA occurred in 29 patients (23.7%). After adjustment for ejection fraction, age, and sex, impaired stress MBF was associated with an increased risk of VA (adjusted HR per ml/min/g 1.52, 95% CI (1.01-2.31), P = 0.04). Summed rest and stress scores were not predictive of VA. Among patients with severe LV dysfunction, stress MBF remained an independent predictor of VA (adjusted HR per 1 ml/min/g HR 1.69, 95% CI (1.03-11.36), P = 0.03), while residual EF, summed rest, and summed stress scores were not (P > 0.05). CONCLUSIONS: Impaired stress myocardial blood flow was associated with less survival free of ventricular arrhythmias.


Asunto(s)
Arritmias Cardíacas/diagnóstico por imagen , Circulación Coronaria , Desfibriladores Implantables/efectos adversos , Ventrículos Cardíacos/diagnóstico por imagen , Corazón/diagnóstico por imagen , Anciano , Cardiomiopatías/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Corazón/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/patología , Imagen de Perfusión Miocárdica , Perfusión , Tomografía de Emisión de Positrones , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/terapia , Resultado del Tratamiento
9.
Pacing Clin Electrophysiol ; 42(7): 980-988, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30969440

RESUMEN

BACKGROUND: Heart block requiring a pacemaker is common after self-expandable transcatheter aortic valve replacement (SE-TAVR); however, conduction abnormalities may improve over time. Optimal device management in these patients is unknown. OBJECTIVE: To evaluate the long-term, natural history of conduction disturbances in patients undergoing pacemaker implantation following SE-TAVR. METHODS: All patients who underwent new cardiac implantable electronic device (CIED) implantation at Michigan Medicine following SE-TAVR placement between January 1, 2012 and September 25, 2017 were identified. Electrocardiogram and device interrogation data were examined during follow-up to identify patients with recovery of conduction. Logistic regression analysis was used to compare clinical and procedural variables to predict conduction recovery. RESULTS: Following SE-TAVR, 17.5% of patients underwent device placement for new atrioventricular (AV) block. Among 40 patients with an average follow-up time of 17.1 ± 8.1 months, 20 (50%) patients had durable recovery of AV conduction. Among 20 patients without long-term recovery, four (20%) had transient recovery. The time to transient conduction recovery was 2.2 ± 0.2 months with repeat loss of conduction at 8.2 ± 0.9 months. On multivariate analysis, larger aortic annular size (odds ratio: 0.53 [0.28-0.86]/mm, P = 0.02) predicted lack of conduction recovery. CONCLUSIONS: Half of the patients undergoing CIED placement for heart block following SE-TAVR recovered AV conduction within several months and maintained this over an extended follow-up period. Some patients demonstrated transient recovery of conduction before recurrence of conduction loss. Larger aortic annulus diameter was negatively associated with conduction recovery.


Asunto(s)
Bloqueo Atrioventricular/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Electrocardiografía , Femenino , Humanos , Masculino
10.
J Cardiovasc Electrophysiol ; 29(2): 284-290, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29071765

RESUMEN

INTRODUCTION: Although noninferiority of cryoballoon ablation (CBA) and radiofrequency catheter ablation for antral pulmonary vein isolation (APVI) has been reported in patients with paroxysmal atrial fibrillation (PAF), it is not clear whether contact force sensing (CF-RFA) and CBA with the second-generation catheter have similar procedural costs and long-term outcomes. The objective of this study is to compare the long-term efficacy and cost implications of CBA and CF-RFA in patients with PAF. METHODS AND RESULTS: A first APVI was performed in 146 consecutive patients (age: 63 ± 10 years, men: 95 [65%], left atrial diameter: 42 ± 6 mm) with PAF using CBA (71) or CF-RFA (75). Clinical outcomes and procedural costs were compared. The mean procedure time was significantly shorter with CBA than with CF-RFA (98 ± 39 vs. 158 ± 47 minutes, P < 0.0001). Despite a higher equipment cost in the CBA than the CF-RFA group, the total procedure cost was similar between the two groups (P = 0.26), primarily driven by a shorter procedure duration that resulted in a lower anesthesia cost. At 25 ± 5 months after a single ablation procedure, 51 patients (72%) in the CBA, and 55 patients (73%) in the CF-RFA groups remained free from atrial arrhythmias without antiarrhythmic drug therapy (P = 0.84). CONCLUSIONS: The procedure duration was approximately 60 minutes shorter with CBA than CF-RFA. The procedural costs were similar with both approaches. At 2 years after a single procedure, CBA and CF-RFA have similar single-procedure efficacies of 72-73%.


Asunto(s)
Fibrilación Atrial/economía , Fibrilación Atrial/cirugía , Ablación por Catéter/economía , Criocirugía/economía , Costos de Hospital , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Anestesia/economía , Antiarrítmicos/economía , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Costos de los Medicamentos , Técnicas Electrofisiológicas Cardíacas/economía , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Supervivencia sin Progresión , Venas Pulmonares/fisiopatología , Recurrencia , Reoperación/economía , Estudios Retrospectivos , Factores de Tiempo
11.
Pacing Clin Electrophysiol ; 41(7): 799-806, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29659027

RESUMEN

BACKGROUND: The safety of perioperative anticoagulation (AC) and antiplatelet (AP) therapy with subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation is unknown. The purpose of this study was to identify the risk factors associated with hematoma complicating S-ICD implantation. METHODS: Records were retrospectively reviewed from 200 consecutive patients undergoing S-ICD implantation at two academic medical centers. A hematoma was defined as a device site blood accumulation requiring surgical evacuation, extended hospital stay, or transfusion. RESULTS: Among 200 patients undergoing S-ICD implantation (age 49 ± 17 years, 67% men), 10 patients (5%) had a hematoma, which required evacuation in six patients (3%). Warfarin was bridged or uninterrupted in 12 and 13 patients, respectively (6% and 6.5%). Four of 12 patients with warfarin and bridging AC (33%) and two of 13 patients with uninterrupted warfarin (15%) developed a hematoma. Neither of the two patients with uninterrupted DOAC had a hematoma. No patients on interrupted AC without bridging (n = 26, 13 with warfarin, 13 with DOAC) developed a hematoma. A hematoma was also more likely with the use of clopidogrel (n = 4/10 vs 10/190, 40% vs 5.3%, P < 0.0001) in combination with aspirin in 12/14 patients. Any bridging AC (odds ratio [OR] 10.3, 1.8-60.8, P = 0.01), clopidogrel (OR 10.0, 1.7-57.7, P = 0.01), and uninterrupted warfarin without bridging (OR 11.1, 1.7-74.3, P = 0.013) were independently associated with hematoma formation. CONCLUSION: AC and/or AP therapy with clopidogrel appears to increase the risk for hematoma following S-ICD implantation. Interruption of AC without bridging should be considered when it is an acceptable risk to hold AC.


Asunto(s)
Anticoagulantes/efectos adversos , Aspirina/efectos adversos , Clopidogrel/efectos adversos , Desfibriladores Implantables , Hematoma/inducido químicamente , Hematoma/epidemiología , Inhibidores de Agregación Plaquetaria/efectos adversos , Complicaciones Posoperatorias/inducido químicamente , Complicaciones Posoperatorias/epidemiología , Warfarina/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Implantación de Prótesis/métodos , Estudios Retrospectivos , Factores de Riesgo
12.
Curr Cardiol Rep ; 14(6): 667-72, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22890754

RESUMEN

There are many prospective clinical trials that have examined cardiovascular outcomes over the past 2 decades. Trials completed within the last 5 years clearly indicate that overall cardiovascular risk is reduced by blood pressure lowering to levels below 140/90 mm Hg. Greater cardiovascular risk reduction is not seen, however, by driving blood pressure to levels well below 130/80 mm Hg. This is true across the spectrum of cardio-renal risk with few exceptions, stroke prevention possibly being one. Further there should be an awareness that outcome studies performed within the last decade will not have the same risk reduction of a given class of antihypertensive drug previously tested. This is primarily due to an improved standard of care that was not present in trials of a decade ago and thus, more recent trials have lower cardiovascular risk at baseline. Lastly, new guidelines will most likely change the goal blood pressure to <140/90 mm Hg as all data support this level. Lastly, the caution of lowering diastolic blood pressure below 60 mm Hg especially in the elderly must be avoided to minimize reductions in coronary perfusion.


Asunto(s)
Antihipertensivos/uso terapéutico , Enfermedad de la Arteria Coronaria/complicaciones , Hipertensión , Presión Sanguínea , Humanos , Hipertensión/complicaciones , Hipertensión/tratamiento farmacológico , Planificación de Atención al Paciente
13.
J Interv Card Electrophysiol ; 63(2): 341-343, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34027564

RESUMEN

PURPOSE: The use of vascular closure devices in patients receiving the Micra leadless pacemaker may shorten time to ambulation, facilitate same-day discharge, and reduce risk of venous thrombosis associated with manual hemostasis. We sought evaluate the feasibility of double Perclose ProGlide (Abbott, CA) preclosure for access site hemostasis after leadless pacemaker implant. METHODS: Patients with leadless pacemaker implant and double preclosure for access hemostasis from 2020 to 2021 were reviewed for complications requiring increase of flat time or transfusion, incidence of venous thromboembolism, and hemoglobin decrement. Two ProGlide devices were deployed with a double preclose technique after ultrasound guided wire access. Patients were instructed to lay flat for 2-4 h and were allowed to ambulate after. RESULTS: A total of 36 patients (age 74.5 ± 15.1 years, BMI 27.9 ± 9.0 kg/m2, 30% female gender) were included with 6 having prior venous thromboembolism, 21 with AF, and 15 with chronic kidney disease. Anticoagulation was continued in 14 (8 direct oral anticoagulants, 2 warfarin, 4 intravenous heparin) and interrupted in 5. In one patient, minor rebleeding prompted 10 min of manual pressure and extension of flat time by 2 h. No patients had other complications, prolongation of flat time, transfusion, delayed re-initiation of anticoagulation, or venous thromboembolism within 30 days. CONCLUSIONS: The double preclose technique is a safe and feasible method of achieving access site hemostasis and facilitates early ambulation after leadless pacemaker implantation.


Asunto(s)
Marcapaso Artificial , Dispositivos de Cierre Vascular , Anciano , Anciano de 80 o más Años , Femenino , Arteria Femoral , Humanos , Masculino , Persona de Mediana Edad , Punciones/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Dispositivos de Cierre Vascular/efectos adversos
14.
J Interv Card Electrophysiol ; 64(2): 311-319, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33821386

RESUMEN

PURPOSE: We aim to describe the long-term safety and efficacy of catheter ablation (CA) in young patients (<30 years) with atrial fibrillation (AF). METHODS: This was a retrospective study of patients aged 18-30 who underwent CA for AF, and clinical characteristics and long-term outcomes are reported. Survival analyses were performed between the study group and a propensity-matched older cohort (>30 years, mean age: 58±10 years). RESULTS: From January 2000 to January 2019, a 1st CA (radiofrequency energy n=72, cryoballoon n=10), was performed in 82 patients (mean age 26±4 years, paroxysmal n=61, persistent n=14, longstanding persistent n=7), among 6336 consecutive patients with AF. During a follow-up of 5±5 years, 56% and 30% of the patients with paroxysmal and non-paroxysmal AF were arrhythmia free without antiarrhythmic drug (AAD) therapy after a single CA (P=0.02). After 1.5±0.8 CA procedures, 76% and 75% of the patients with paroxysmal AF and non-paroxysmal AF were arrhythmia free without AADs (P=0.54). Compared to a propensity-matched group of older patients, young patients were as likely to remain in sinus rhythm after CA (P=0.47), however after fewer repeat CAs (1.5±0.8 vs 1.9±0.9, P<0.009). There were no long-term adverse outcomes associated with CA. CONCLUSIONS: CA is a safe and effective treatment of AF in young patients with comparable outcomes to the older patients, however after fewer procedures.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Adulto , Anciano , Antiarrítmicos/uso terapéutico , Ablación por Catéter/métodos , Humanos , Persona de Mediana Edad , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
15.
JACC Clin Electrophysiol ; 7(5): 642-648, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33812835

RESUMEN

OBJECTIVES: The study's goal was to compare the efficacy and safety of dofetilide (DOF) versus amiodarone (AMIO) in patients with atrial fibrillation (AF). BACKGROUND: Comparative efficacy of DOF versus AMIO in patients with AF has not been well established. In addition, proarrhythmia has been a concern with DOF therapy. METHODS: Rhythm control was attempted by using DOF in 657 consecutive patients (mean age 72 ± 9 years; 35% women) with AF (n = 528) or atrial flutter and AF (n = 129) between January 2014 and December 2018. RESULTS: DOF was successfully initiated in 573 (87%) of 657 patients, including 510 (89%) with persistent AF and 63 (11%) with paroxysmal AF. During a mean follow-up of 19 ± 7 months, sinus rhythm was maintained in 361 (63%) of the 573 DOF-treated patients. At 12 months, patients on DOF had a similar likelihood of experiencing recurrent atrial arrhythmias compared with the 2,476 consecutive patients treated with AMIO for rhythm control during the study period (37% vs. 39%; p = 0.56). The efficacy of DOF and AMIO was also similar in specific subgroups of patients, including patients >75 years of age, with a low left ventricular ejection fraction, obesity, renal insufficiency, and prior catheter ablation for AF. Among patients with atypical atrial flutter, likelihood of recurrent atrial flutter was similar between the DOF (43 of 108 [40%]) and AMIO (211 of 555 [38%]; p = 0.69) groups. CONCLUSIONS: When properly initiated and monitored, DOF has efficacy comparable to that of amiodarone for rhythm control in patients with AF.


Asunto(s)
Amiodarona , Fibrilación Atrial , Anciano , Anciano de 80 o más Años , Amiodarona/efectos adversos , Antiarrítmicos/efectos adversos , Fibrilación Atrial/tratamiento farmacológico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fenetilaminas , Volumen Sistólico , Sulfonamidas , Función Ventricular Izquierda
17.
Clin Imaging ; 58: 145-151, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31336361

RESUMEN

PURPOSE: The purpose of this study was to describe the safety and efficacy of hybrid recanalization procedures in a series of patients with obstructed central veins requiring cardiac implantable electronic device (CIED) revision. METHODS: Between 2008 and 2016, 38 consecutive patients (24 M; age 60.5 ±â€¯16.2 years; range 25-87 years) with central venous obstruction underwent 42 recanalization interventions performed in conjunction with CIED revision or extraction. Fifty percent of patients (19/38) presented with veno-occlusive symptoms, and 13% (5/38) of patients had CIED leads with an ipsilateral upper extremity dialysis conduit. RESULTS: Ninety-one percent (38/42) of all procedures resulted in successful recanalization and CIED revision. Twenty-four percent (9/38) of all patients required secondary procedures due to recurrent stenosis, and 78% (7/9) of those requiring secondary procedures had indwelling dialysis conduits and/or clinical symptoms related to venous occlusion before the initial procedure. There were complications in 2 patients related to recanalization, and in 3 related to CIED revision. CONCLUSIONS: Recanalization of central venous stenosis/occlusion in patients with CIED can be technically challenging but is successful in most patients. Symptomatic patients and those with dialysis conduits often require more aggressive revascularization interventions and may be at increased risk of complication or need for secondary interventions.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/efectos adversos , Cateterismo/métodos , Desfibriladores Implantables , Reoperación/estadística & datos numéricos , Enfermedades Vasculares/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Constricción Patológica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
18.
Heart Rhythm ; 16(9): 1368-1373, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31201962

RESUMEN

BACKGROUND: It is not clear if antiarrhythmic drug therapy (AAD) after catheter ablation (CA) of atrial fibrillation (AF) increases mortality. OBJECTIVE: To determine whether there is an association between AAD therapy and mortality after CA of AF. METHODS: There were 3624 consecutive patients with AF (mean age: 59 ± 11 years, women: 27%, paroxysmal AF: 58%). An AAD was used in 2253 patients (62%, AAD group) for a mean duration of 1.3 ± 0.8 years, during a mean follow-up of 6.7 ± 2.2 years after CA of AF. Using propensity score matching, with every 2 patients using an AAD matched to 1 patient who did not use AAD (NO-AAD group), Cox regression models were utilized to assess the association between AAD use (as a time-variable covariate) and all-cause mortality. RESULTS: There were a total of 50 deaths (2.2%) in the AAD and 62 deaths (4.5%) in the NO-AAD groups, respectively (P = .02). At the time of death, 46 of 50 patients (92%) who died in the AAD cohort were still using an AAD (P = .21, compared to baseline use). On multivariate analysis, although the risk of death was not statistically significant between the AAD and NO-AAD cohorts, there was a trend towards mortality benefit with AAD therapy (hazard ratio [HR]: 0.66, 95% confidence interval [CI]: 0.43-1.00, P = .05), regardless of the rhythm or anticoagulation status. CONCLUSION: AAD use after CA of AF is not associated with an increased risk of mortality, suggesting that when carefully chosen and monitored, AADs appear to be safe after CA of AF.


Asunto(s)
Antiarrítmicos , Fibrilación Atrial , Ablación por Catéter , Monitoreo Fisiológico , Medición de Riesgo/métodos , Antiarrítmicos/administración & dosificación , Antiarrítmicos/efectos adversos , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/mortalidad , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Ablación por Catéter/estadística & datos numéricos , Causas de Muerte , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Mortalidad , Selección de Paciente , Periodo Posoperatorio , Puntaje de Propensión , Estados Unidos/epidemiología
19.
Heart Rhythm ; 15(1): 17-24, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28765086

RESUMEN

BACKGROUND: The role of the ligament of Marshall (LOM) in patients with atrial fibrillation (AF) has not been well defined. OBJECTIVE: The purpose of this study was to describe the role of the LOM in patients with AF and related arrhythmias. METHODS: Fifty-six patients (mean age 63 ± 11 years; persistent AF in 48 [86%]; ejection fraction 0.49 ± 0.13; left atrial diameter 4.7 ± 0.6 cm) with LOM-mediated arrhythmias were included. RESULTS: A LOM-pulmonary vein (PV) connection was present in 18 patients (32%) and was eliminated with radiofrequency (RF) ablation at the left lateral ridge or crux (n = 12), at the mitral annulus (n = 3), or with alcohol/ethanol (EtOH) ablation of the vein of Marshall (VOM; n = 3). A LOM-mediated atrial tachycardia (AT) was present in 13 patients (23%). Thirty-one patients with refractory mitral isthmus conduction were referred for potential EtOH ablation. In the 6 patients in whom VOM was injected during perimitral reentry, EtOH resulted in slowing in 3 patients and termination in 1 patient. In others, EtOH infusion resulted in complete isolation of the left-sided PVs and left atrial appendage. Repeat RF and adjunctive EtOH ablation of the VOM tended to be more effective in creating conduction block across the mitral isthmus than RF ablation alone (P = .057). CONCLUSION: The LOM is responsible for a variety of arrhythmia mechanisms in patients with AF and atrial tachycardia. It may be ablated at any point along its course, at the mitral annulus, at the lateral ridge/PV antrum, and epicardially in the coronary sinus and the VOM itself. EtOH ablation of the VOM may be an adjunctive strategy in patients with refractory perimitral reentry.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Sistema de Conducción Cardíaco/cirugía , Frecuencia Cardíaca/fisiología , Ligamentos/diagnóstico por imagen , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Técnicas Electrofisiológicas Cardíacas , Femenino , Sistema de Conducción Cardíaco/diagnóstico por imagen , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Ligamentos/fisiopatología , Ligamentos/cirugía , Masculino , Persona de Mediana Edad , Flebografía , Venas Pulmonares/diagnóstico por imagen , Estudios Retrospectivos , Resultado del Tratamiento
20.
Heart Rhythm ; 15(12): 1835-1841, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30509365

RESUMEN

BACKGROUND: The role of cryoballoon ablation (CBA) for antral pulmonary vein isolation (APVI) has not been well established in persistent atrial fibrillation (PerAF). Isolation of the left atrial posterior wall (BOX) after APVI has been suggested to improve the efficacy of radiofrequency catheter ablation (RFA) in PerAF. OBJECTIVE: The purpose of this study was to compare characteristics and clinical outcomes of APVI by CBA vs APVI + BOX by contact force-guided RFA (CF-RFA) in patients with PerAF. METHODS: APVI was performed in 167 consecutive patients with PerAF (mean age 64 ± 9 years; left atrial diameter 46 ± 6 mm) using CBA (n = 90) or CF-RFA (n = 77). After APVI, a roofline was created in 33 of 90 patients (37%) in the CBA group and BOX was performed in all 77 patients in the CF-RFA group. RESULTS: During 21 ± 10 months of follow-up after a single ablation procedure, 37 of 90 patients (41%) in the CBA group (APVI) and 39 of 77 (51%) in the CF-RFA group (APVI + BOX) remained in sinus rhythm without antiarrhythmic drugs (AADs) (P = .22). During repeat ablation, APVI + BOX using CF-RFA was performed in 20 of 90 patients (22%) and in 18 of 77 patients (23%) who initially underwent CBA or CF-RFA, respectively. At 19 ± 10 months after repeat ablation, sinus rhythm was maintained in 55 of 90 patients (61%) and 52 of 77 patients (68%) in the CBA and CF-RFA groups without AADs, respectively (P = .39). CONCLUSION: In PerAF, an initial approach of APVI by CBA or APVI + BOX by CF-RFA has a similar efficacy of 40%-50% without AADs. After repeat ablation for APVI + BOX by CF-RFA in ∼25%, sinus rhythm is maintained in 60%-70% of patients without AADs.


Asunto(s)
Fibrilación Atrial/cirugía , Mapeo del Potencial de Superficie Corporal , Ablación por Catéter/instrumentación , Criocirugía/métodos , Atrios Cardíacos/cirugía , Sistema de Conducción Cardíaco/cirugía , Venas Pulmonares/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/fisiopatología , Diseño de Equipo , Femenino , Estudios de Seguimiento , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA