Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 187
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Europace ; 26(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38291778

RESUMEN

AIMS: To predict worsening heart failure hospitalizations (WHFHs) in patients with implantable defibrillators and remote monitoring, the HeartInsight algorithm (Biotronik, Berlin, Germany) calculates a heart failure (HF) score combining seven physiologic parameters: 24 h heart rate (HR), nocturnal HR, HR variability, atrial tachyarrhythmia, ventricular extrasystoles, patient activity, and thoracic impedance. We compared temporal trends of the HF score and its components 12 weeks before a WHFH with 12-week trends in patients without WHFH, to assess whether trends indicate deteriorating HF regardless of alert status. METHODS AND RESULTS: Data from nine clinical trials were pooled, including 2050 patients with a defibrillator capable of atrial sensing, ejection fraction ≤ 35%, NYHA class II/III, no long-standing atrial fibrillation, and 369 WHFH from 259 patients. The mean HF score was higher in the WHFH group than in the no WHFH group (42.3 ± 26.1 vs. 30.7 ± 20.6, P < 0.001) already at the beginning of 12 weeks. The mean HF score further increased to 51.6 ± 26.8 until WHFH (+22% vs. no WHFH group, P = 0.003). As compared to the no WHFH group, the algorithm components either were already higher 12 weeks before WHFH (24 h HR, HR variability, thoracic impedance) or significantly increased until WHFH (nocturnal HR, atrial tachyarrhythmia, ventricular extrasystoles, patient activity). CONCLUSION: The HF score was significantly higher at, and further increased during 12 weeks before WHFH, as compared to the no WHFH group, with seven components showing different behaviour and contribution. Temporal trends of HF score may serve as a quantitative estimate of HF condition and evolution prior to WHFH.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Taquicardia Ventricular , Humanos , Hospitalización , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Complejos Cardíacos Prematuros
2.
Sensors (Basel) ; 24(7)2024 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-38610543

RESUMEN

In the framework of the PREDIS EU project, a wireless battery-operated gamma-ray detection system was developed in order to provide a medium-to-long-term monitoring system for radioactive waste drums. It was initially proposed to monitor the gamma radioactivity outcoming from steel drums containing cemented radwaste, even though it could be usefully employed in a wider range of applications. Gamma rays are penetrating and convey information from the drum's internal structure, as the count rate measured on the surface depends on the thickness and density of the crossed materials. A number of sensors arranged around a drum, typically four units, provide indications of the emission anisotropy, and any sensitive change in the measured count rate would hint at some anomaly, thus triggering a suitable inspection by operators.

3.
J Cardiovasc Electrophysiol ; 34(4): 947-956, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36709469

RESUMEN

INTRODUCTION: Thoracic impedance (TI) drops measured by implantable cardioverter-defibrillators (ICDs) have been reported to correlate with ventricular tachycardia/fibrillation (VT/VF). The aim of our study was to assess the temporal association of decreasing TI trends with VT/VF episodes through a longitudinal analysis of daily remote monitoring data from ICDs and cardiac resynchronization therapy defibrillators (CRT-Ds). METHODS AND RESULTS: Retrospective data from 2384 patients were randomized 1:1 into a derivation or validation cohort. The TI decrease rate was defined as the percentage of rolling weeks with a continuously decreasing TI trend. The derivation cohort was used to determine a TI decrease rate threshold for a ≥99% specificity of arrhythmia prediction. The associated risk of VT/VF episodes was estimated in the validation cohort by dividing the available follow-up into 60-day assessment intervals. Analyses were performed separately for 1354 ICD and 1030 CRT-D patients. During a median follow-up of 2.0 years, 727 patients (30.4%) experienced 3298 confirmed VT/VF episodes. In the ICD group, a TI decrease rate of >60% was associated with a higher risk of VT/VF episode in a 60-day assessment interval (stratified hazard ratio, 1.42; 95% confidence interval (CI), 1.05-1.92; p = .023). The TI decrease preceded (40.8%) or followed (59.2%) the VT/VF episodes. In the CRT-D group, no association between TI decrease and VT/VF episodes was observed (p = .84). CONCLUSION: In our longitudinal analysis, TI decrease was associated with VT/VF episodes only in ICD patients. Preventive interventions may be difficult since episodes can occur before or after TI decrease.


Asunto(s)
Arritmias Cardíacas , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/terapia , Impedancia Eléctrica , Estudios Retrospectivos , Fibrilación Ventricular , Desfibriladores Implantables
4.
J Cardiovasc Pharmacol ; 81(2): 129-133, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36607629

RESUMEN

ABSTRACT: Dual pathway inhibition (DPI) with low-dose rivaroxaban and aspirin in patients with coronary artery disease (CAD) and/or peripheral artery disease (PAD) reduces the occurrence of cardiovascular (CV) events; however, the underlying mechanisms explaining these latter CV benefits are not clearly understood. Our explorative observational study aimed to evaluate the effect of dual pathway inhibition on plasma inflammation and coagulation markers among real-world patients with CAD and/or PAD. We prospectively included all consecutive patients with an established diagnosis of CAD and/or PAD treated with aspirin 100 mg once daily (OD) and rivaroxaban 2.5 mg twice daily (TD). Clinical evaluation and laboratory analyses, including hemoglobin, renal function (creatinine, urea, and cystatin-C), coagulation markers (INR and aPTT), inflammation markers (IL-6, CRP, lipoprotein-associated phospholipase A2, and copeptin), and growth differentiation factor-15 (GDF-15), were conducted at baseline, before starting treatment, and at 4 and 24 weeks after study drug administration. Fifty-four consecutive patients (mean age 66 ± 7 years; male 83%) who completed the 6-month follow-up were included. At 24-week follow-up, a statistically significant reduction in IL-6 serum levels [4.6 (3.5-6.5) vs. 3.4 (2.4-4.3) pg/mL ; P = 0.0001] and fibrinogen [336 (290-390) vs. 310 (275-364) mg/dL; P = 0.04] was shown; moreover, a significant increase in GDF-15 serum level [1309 (974-1961) vs. 1538 (1286-2913) pg/mL; P = 0.002] was observed. Hemoglobin, renal function, and cardiovascular homeostasis biomarkers remain stable over the time. The anti-Xa activity at both [0.005 (0-0.02) vs. 0.2 (0.1-0.34); P < 0.0001) significantly increased. The dual pathway inhibitions with low-dose rivaroxaban and aspirin in patients with CAD and/or PAD were associated with the reduction of inflammation biomarkers.


Asunto(s)
Aterosclerosis , Enfermedad de la Arteria Coronaria , Enfermedad Arterial Periférica , Anciano , Humanos , Masculino , Persona de Mediana Edad , Aspirina , Aterosclerosis/tratamiento farmacológico , Biomarcadores , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Quimioterapia Combinada , Inhibidores del Factor Xa , Factor 15 de Diferenciación de Crecimiento , Inflamación/tratamiento farmacológico , Interleucina-6 , Enfermedad Arterial Periférica/tratamiento farmacológico , Inhibidores de Agregación Plaquetaria , Rivaroxabán , Femenino
5.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-36942949

RESUMEN

AIMS: In bradycardia patients treated with dual-chamber pacing, we aimed to evaluate whether pacing with atrioventricular (AV) delay management [AV hysteresis (AVH)], compared with standard pacing with fixed AV delays, reduces unnecessary ventricular pacing percentage (VPP) and is associated with better clinical outcomes. Main study endpoints were the incidence of heart failure hospitalizations (HFH), persistent atrial fibrillation (AF), and cardiac death. METHODS AND RESULTS: Data from two identical prospective observational studies, BRADYCARE I in the USA and BRADYCARE II in Europe, Africa, and Asia, were pooled. Overall, 2592 patients (75 ± 10 years, 45.1% female, 50% with AVH) had complete clinical and device data at 1-year follow-up and were analysed. Primary pacing indication was sinus node disease (SND) in 1177 (45.4%), AV block (AVB) in 974 (37.6%), and other indications in 441 (17.0%) patients. Pacing with AVH, compared with standard pacing, was associated with a lower 1-year incidence of HFH [1.3% vs. 3.1%, relative risk reduction (RRR) 57.5%, P = 0.002] and of persistent AF (5.3% vs. 7.7%, RRR = 31.1%, P = 0.028). Cardiac mortality was not different between groups (1.0% vs. 1.4%, RRR = 27.8%, P = 0.366). Pacing with AVH, compared with standard pacing, was associated with a lower (P < 0.001) median VPP in all patients (7% vs. 75%), in SND (3% vs. 44%), in AVB (25% vs. 98%), and in patients with other pacing indications (3% vs. 47%). CONCLUSION: Cardiac pacing with AV delay management via AVH is associated with reduced 1-year incidence of HFH and persistent AF, most likely due to a reduction in VPP compared to standard pacing.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Marcapaso Artificial , Humanos , Femenino , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/prevención & control , Estimulación Cardíaca Artificial/métodos , Incidencia , Resultado del Tratamiento , Marcapaso Artificial/efectos adversos , Síndrome del Seno Enfermo/terapia , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/prevención & control , Hospitalización
6.
Europace ; 25(4): 1467-1474, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36881780

RESUMEN

AIMS: Patients with atrial fibrillation frequently experience sleep disorder breathing, and both conditions are highly prevalent in presence of heart failure (HF). We explored the association between the combination of an HF and a sleep apnoea (SA) index and the incidence of atrial high-rate events (AHRE) in patients with implantable defibrillators (ICDs). METHODS AND RESULTS: Data were prospectively collected from 411 consecutive HF patients with ICD. The IN-alert HF state was measured by the multi-sensor HeartLogic Index (>16), and the ICD-measured Respiratory Disturbance Index (RDI) was computed to identify severe SA. The endpoints were as follows: daily AHRE burden of ≥5 min, ≥6 h, and ≥23 h. During a median follow-up of 26 months, the time IN-alert HF state was 13% of the total observation period. The RDI value was ≥30 episodes/h (severe SA) during 58% of the observation period. An AHRE burden of ≥5 min/day was documented in 139 (34%) patients, ≥6 h/day in 89 (22%) patients, and ≥23 h/day in 68 (17%) patients. The IN-alert HF state was independently associated with AHRE regardless of the daily burden threshold: hazard ratios from 2.17 for ≥5 min/day to 3.43 for ≥23 h/day (P < 0.01). An RDI ≥ 30 episodes/h was associated only with AHRE burden ≥5 min/day [hazard ratio 1.55 (95% confidence interval: 1.11-2.16), P = 0.001]. The combination of IN-alert HF state and RDI ≥ 30 episodes/h accounted for only 6% of the follow-up period and was associated with high rates of AHRE occurrence (from 28 events/100 patient-years for AHRE burden ≥5 min/day to 22 events/100 patient-years for AHRE burden ≥23 h/day). CONCLUSIONS: In HF patients, the occurrence of AHRE is independently associated with the ICD-measured IN-alert HF state and RDI ≥ 30 episodes/h. The coexistence of these two conditions occurs rarely but is associated with a very high rate of AHRE occurrence. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Insuficiencia Cardíaca , Síndromes de la Apnea del Sueño , Humanos , Desfibriladores Implantables/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Medición de Riesgo , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia
7.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37656991

RESUMEN

AIMS: The HeartLogic Index combines data from multiple implantable cardioverter defibrillators (ICDs) sensors and has been shown to accurately stratify patients at risk of heart failure (HF) events. We evaluated and compared the performance of this algorithm during sinus rhythm and during long-lasting atrial fibrillation (AF). METHODS AND RESULTS: HeartLogic was activated in 568 ICD patients from 26 centres. We found periods of ≥30 consecutive days with an atrial high-rate episode (AHRE) burden <1 h/day and periods with an AHRE burden ≥20 h/day. We then identified patients who met both criteria during the follow-up (AHRE group, n = 53), to allow pairwise comparison of periods. For control purposes, we identified patients with an AHRE burden <1 h throughout their follow-up and implemented 2:1 propensity score matching vs. the AHRE group (matched non-AHRE group, n = 106). In the AHRE group, the rate of alerts was 1.2 [95% confidence interval (CI): 1.0-1.5]/patient-year during periods with an AHRE burden <1 h/day and 2.0 (95% CI: 1.5-2.6)/patient-year during periods with an AHRE-burden ≥20 h/day (P = 0.004). The rate of HF hospitalizations was 0.34 (95% CI: 0.15-0.69)/patient-year during IN-alert periods and 0.06 (95% CI: 0.02-0.14)/patient-year during OUT-of-alert periods (P < 0.001). The IN/OUT-of-alert state incidence rate ratio of HF hospitalizations was 8.59 (95% CI: 1.67-55.31) during periods with an AHRE burden <1 h/day and 2.70 (95% CI: 1.01-28.33) during periods with an AHRE burden ≥20 h/day. In the matched non-AHRE group, the rate of HF hospitalizations was 0.29 (95% CI: 0.12-0.60)/patient-year during IN-alert periods and 0.04 (95% CI: 0.02-0.08)/patient-year during OUT-of-alert periods (P < 0.001). The incidence rate ratio was 7.11 (95% CI: 2.19-22.44). CONCLUSION: Patients received more alerts during periods of AF. The ability of the algorithm to identify increased risk of HF events was confirmed during AF, despite a lower IN/OUT-of-alert incidence rate ratio in comparison with non-AF periods and non-AF patients. CLINICAL TRIAL REGISTRATION: http://clinicaltrials.gov/Identifier: NCT02275637.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Algoritmos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Atrios Cardíacos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia
8.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-36932709

RESUMEN

AIMS: In subcutaneous implantable cardioverter defibrillator (S-ICD) recipients, the UNTOUCHED study demonstrated a very low inappropriate shock rate on programming a conditional zone between 200 and 250 bpm and a shock zone for arrhythmias >250 bpm. The extent to which this programming approach is adopted in clinical practice is still unknown, as is its impact on the rates of inappropriate and appropriate therapies. METHODS AND RESULTS: We assessed ICD programming on implantation and during follow-up in a cohort of 1468 consecutive S-ICD recipients in 56 Italian centres. We also measured the occurrence of inappropriate and appropriate shocks during follow-up. On implantation, the median programmed conditional zone cut-off was set to 200 bpm (IQR: 200-220) and the shock zone cut-off was 230 bpm (IQR: 210-250). During follow-up, the conditional zone cut-off rate was not significantly changed, while the shock zone cut-off was changed in 622 (42%) patients and the median value increased to 250 bpm (IQR: 230-250) (P < 0.001). UNTOUCHED-like programming of detection cut-offs was adopted in 426 (29%) patients immediately after device implantation, and in 714 (49%, P < 0.001) at the last follow-up. UNTOUCHED-like programming was independently associated with fewer inappropriate shocks (hazard ratio 0.50, 95%CI 0.25-0.98, P = 0.044), and had no impact on appropriate and ineffective shocks. CONCLUSIONS: In recent years, S-ICD implanting centres have increasingly programmed high arrhythmia detection cut-off rates, at the time of implantation in the case of new S-ICD recipients, and during follow-up in the case of pre-existing implants. This has contributed significantly to reducing the incidence of inappropriate shocks in clinical practice. Rordorf: Programming of the S-ICD. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Asunto(s)
Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Desfibriladores Implantables/efectos adversos , Taquicardia Ventricular/diagnóstico , Estudios de Seguimiento , Estudios Prospectivos , Cardioversión Eléctrica , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia
9.
Europace ; 25(6)2023 06 02.
Artículo en Inglés | MEDLINE | ID: mdl-37350404

RESUMEN

AIMS: Subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy is expanding rapidly. However, there are few data on the S-ICD extraction procedure and subsequent patient management. The aim of this analysis was to describe the procedure, management, and outcome of S-ICD extractions in clinical practice. METHODS AND RESULTS: We enrolled consecutive patients who required complete S-ICD extraction at 66 Italian centres. From 2013 to 2022, 2718 patients undergoing de novo implantation of an S-ICD were enrolled. Of these, 71 required complete S-ICD system extraction (17 owing to infection). The S-ICD system was successfully extracted in all patients, and no complications were reported; the median procedure duration was 40 (25th-75th percentile: 20-55) min. Simple manual traction was sufficient to remove the lead in 59 (84%) patients, in whom lead-dwelling time was shorter [20 (9-32) months vs. 30 (22-41) months; P = 0.032]. Hospitalization time was short in the case of both non-infectious [2 (1-2) days] and infectious indications [3 (1-6) days]. In the case of infection, no patients required post-extraction intravenous antibiotics, the median duration of any antibiotic therapy was 10 (10-14) days, and the re-implantation was performed during the same procedure in 29% of cases. No complications arose over a median of 21 months. CONCLUSION: The S-ICD extraction was safe and easy to perform, with no complications. Simple traction of the lead was successful in most patients, but specific tools could be needed for systems implanted for a longer time. The peri- and post-procedural management of S-ICD extraction was free from complications and not burdensome for patients and healthcare system. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Asunto(s)
Desfibriladores Implantables , Humanos , Administración Intravenosa , Antibacterianos , Hospitalización , Resultado del Tratamiento
10.
Europace ; 25(4): 1423-1431, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36794691

RESUMEN

AIMS: A previous randomized study demonstrated that the subcutaneous implantable cardioverter defibrillator (S-ICD) was noninferior to transvenous ICD with respect to device-related complications and inappropriate shocks. However, that was performed prior to the widespread adoption of pulse generator implantation in the intermuscular (IM) space instead of the traditional subcutaneous (SC) pocket. The aim of this analysis was to compare survival from device-related complications and inappropriate shocks between patients who underwent S-ICD implantation with the generator positioned in an IM position in comparison with an SC pocket. METHODS AND RESULTS: We analysed 1577 consecutive patients who had undergone S-ICD implantation from 2013 to 2021 and were followed up until December 2021. Subcutaneous patients (n = 290) were propensity matched with patients of the IM group (n = 290), and their outcomes were compared. : During a median follow-up of 28 months, device-related complications were reported in 28 (4.8%) patients and inappropriate shocks were reported in 37 (6.4%) patients. The risk of complication was lower in the matched IM group than in the SC group [hazard ratio 0.41, 95% confidence interval (CI) 0.17-0.99, P = 0.041], as well as the composite of complications and inappropriate shocks (hazard ratio 0.50, 95% CI 0.30-0.86, P = 0.013). The risk of appropriate shocks was similar between groups (hazard ratio 0.90, 95% CI 0.50-1.61, P = 0.721). There was no significant interaction between generator positioning and variables such as gender, age, body mass index, and ejection fraction. CONCLUSION: Our data showed the superiority of the IM S-ICD generator positioning in reducing device-related complications and inappropriate shocks. CLINICAL TRIAL REGISTRATION: Clinical Trial Registration: ClinicalTrials.gov; NCT02275637.


Asunto(s)
Desfibriladores Implantables , Humanos , Desfibriladores Implantables/efectos adversos , Estudios de Casos y Controles , Muerte Súbita Cardíaca/etiología , Estudios Retrospectivos , Resultado del Tratamiento
11.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37536671

RESUMEN

AIMS: Patients with cardiomyopathies and channelopathies are usually younger and have a predominantly arrhythmia-related prognosis; they have nearly normal life expectancy thanks to the protection against sudden cardiac death provided by the implantable cardioverter defibrillator (ICD). The subcutaneous ICD (S-ICD) is an effective alternative to the transvenous ICD and has evolved over the years. This study aimed to evaluate the rate of inappropriate shocks (IS), appropriate therapies, and device-related complications in patients with cardiomyopathies and channelopathies who underwent modern S-ICD implantation. METHODS AND RESULTS: We enrolled consecutive patients with cardiomyopathies and channelopathies who had undergone implantation of a modern S-ICD from January 2016 to December 2020 and who were followed up until December 2022. A total of 1338 S-ICD implantations were performed within the observation period. Of these patients, 628 had cardiomyopathies or channelopathies. The rate of IS at 12 months was 4.6% [95% confidence interval (CI): 2.8-6.9] in patients with cardiomyopathies and 1.1% (95% CI: 0.1-3.8) in patients with channelopathies (P = 0.032). No significant differences were noted over a median follow-up of 43 months [hazard ratio (HR): 0.76; 95% CI: 0.45-1.31; P = 0.351]. The rate of appropriate shocks at 12 months was 2.3% (95% CI: 1.1-4.1) in patients with cardiomyopathies and 2.1% (95% CI: 0.6-5.3) in patients with channelopathies (P = 1.0). The rate of device-related complications was 0.9% (95% CI: 0.3-2.3) and 3.2% (95% CI: 1.2-6.8), respectively (P = 0.074). No significant differences were noted over the entire follow-up. The need for pacing was low, occurring in 0.8% of patients. CONCLUSION: Modern S-ICDs may be a valuable alternative to transvenous ICDs in patients with cardiomyopathies and channelopathies. Our findings suggest that modern S-ICD therapy carries a low rate of IS. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Asunto(s)
Cardiomiopatías , Canalopatías , Desfibriladores Implantables , Humanos , Desfibriladores Implantables/efectos adversos , Canalopatías/complicaciones , Canalopatías/terapia , Resultado del Tratamiento , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Cardiomiopatías/complicaciones , Cardiomiopatías/terapia , Sistema de Registros
12.
Heart Vessels ; 38(5): 680-688, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36418560

RESUMEN

No real-world data are available about the complications rate in drug-induced type 1 Brugada Syndrome (BrS) patients with an implantable cardioverter-defibrillator (ICD). Aim of our study is to compare the device-related complications, infections, and inappropriate therapies among drug-induced type 1 BrS patients with transvenous- ICD (TV-ICD) versus subcutaneous-ICD (S-ICD). Data for this study were sourced from the IBRYD (Italian BRugada sYnDrome) registry which includes 619 drug-induced type-1 BrS patients followed at 20 Italian tertiary referral hospitals. For the present analysis, we selected 258 consecutive BrS patients implanted with ICD. 198 patients (76.7%) received a TV-ICD, while 60 a S-ICD (23.4%). And were followed-up for a median time of 84.3 [46.5-147] months. ICD inappropriate therapies were experienced by 16 patients (6.2%). 14 patients (7.1%) in the TVICD group and 2 patients (3.3%) in S-ICD group (log-rank P = 0.64). ICD-related complications occurred in 31 patients (12%); 29 (14.6%) in TV-ICD group and 2 (3.3%) in S-ICD group (log-rank P = 0.41). ICD-related infections occurred in 10 patients (3.88%); 9 (4.5%) in TV-ICD group and 1 (1.8%) in S-ICD group (log-rank P = 0.80). After balancing for potential confounders using the propensity score matching technique, no differences were found in terms of clinical outcomes between the two groups. In a real-world setting of drug-induced type-1 BrS patients with ICD, no significant differences in inappropriate ICD therapies, device-related complications, and infections were shown among S-ICD vs TV-ICD. However, a reduction in lead-related complications was observed in the S-ICD group. In conclusion, our evidence suggests that S-ICD is at least non-inferior to TV-ICD in this population and may also reduce the risk of lead-related complications which can expose the patients to the necessity of lead extractions.


Asunto(s)
Síndrome de Brugada , Desfibriladores Implantables , Humanos , Desfibriladores Implantables/efectos adversos , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Síndrome de Brugada/etiología , Puntaje de Propensión , Cardioversión Eléctrica/efectos adversos , Electrocardiografía/métodos , Muerte Súbita Cardíaca/epidemiología , Resultado del Tratamiento
13.
Artículo en Inglés | MEDLINE | ID: mdl-37667884

RESUMEN

Sleep-disordered breathing (SDB) represents an important cardiovascular risk factor that is still often underestimated and not always optimally treated. Such breathing disorders can induce several harmful effects on the heart, also favoring the development of arrhythmias, ischemic heart disease, and left ventricular remodeling. Obstructive sleep apnea syndrome (OSA) is more frequent in heart failure patients than in the general population, promoting the worsening of left ventricular dysfunction. Both sleep apnea and heart failure have common clinical manifestations but also similar neurohormonal characteristics, both contributing to the development and progression of heart failure and resulting in increased mortality. The pathophysiological mechanisms underlying left ventricular dysfunction associated with SDB will be analyzed, and the potential therapeutic effects of gliflozins on OSA in heart failure patients will be discussed.

14.
Medicina (Kaunas) ; 59(2)2023 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-36837457

RESUMEN

Atrial fibrillation (AF) is the most common cardiac arrhythmia associated with an increased thromboembolic risk. The impact of the female sex as an independent risk factor for thromboembolic events in AF is still debated. Background and Objectives: The aim of this review is to evaluate the gender-related differences in cardioembolic risk and response to anticoagulants among AF patients. Materials and Methods: The PubMed database is used to review the reports about gender differences and thromboembolic risk in atrial fibrillation. Results: Non-vitamin K oral anticoagulants (NOACs) represent the gold standard for thromboembolic risk prevention in patients with non-valvular atrial fibrillation (NVAF). Despite a similar rate of stroke and systemic embolism (SE) among men and women in NOACs or vitamin K antagonists (VKAs) treatment, the use of NOACs in AF women is associated with a lower risk of intracranial bleeding, major bleeding, and all-cause mortality than in men. Conclusions: The female sex can be defined as a stroke risk modifier rather than a stroke risk factor since it mainly increases the thromboembolic risk in the presence of other risk factors. Further studies about the efficacy and safety profile of NOACs according to sex are needed to support clinicians in performing the most appropriate and tailored anticoagulant therapy, either in male or female AF patients.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Tromboembolia , Femenino , Humanos , Masculino , Anticoagulantes/uso terapéutico , Fibrilación Atrial/complicaciones , Administración Oral , Factores Sexuales , Accidente Cerebrovascular/complicaciones , Factores de Riesgo
15.
J Cardiovasc Electrophysiol ; 33(7): 1472-1479, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35499267

RESUMEN

INTRODUCTION: The Respiratory Disturbance Index (RDI) computed by an implantable cardioverter defibrillator (ICD) algorithm accurately identifies severe sleep apnea (SA). In the present analysis, we tested the hypothesis that RDI could also predict atrial fibrillation (AF) burden. METHODS: Patients with ejection fraction ≤35% implanted with an ICD were enrolled and followed up for 24 months. One month after implantation, patients underwent a polysomnographic study. The weekly mean RDI value was considered, as calculated during the entire follow-up period and over a 1-week period preceding the sleep study. The endpoints were as follows: daily AF burden of ≥5 min, ≥6 h, ≥23 h. RESULTS: Here, 164 patients had usable RDI values during the entire follow-up period. Severe SA (RDI ≥ 30 episodes/h) was diagnosed in 92 (56%) patients at the time of the sleep study. During follow-up, AF burden ≥ 5 min/day was documented in 70 (43%), ≥6 h/day in 48 (29%), and ≥23 h/day in 33 (20%) patients. Device-detected RDI ≥ 30 episodes/h at the time of the polygraphy, as well as the polygraphy-measured apnea hypopnea index ≥ 30 episodes/h, were not associated with the occurrence of the endpoints, using a Cox regression model. However, using a time-dependent model, continuously measured weekly mean RDI ≥ 30 episodes/h was independently associated with AF burden ≥ 5 min/day (hazard ratio [HR]: 2.13, 95% confidence interval [CI]: 1.24-3.65, p = .006), ≥6 h/day (HR: 2.75, 95% CI: 1.37-5.49, p = .004), and ≥23 h/day (HR: 2.26, 95% CI: 1.05-4.86, p = .037). CONCLUSIONS: In heart failure patients, ICD-diagnosed severe SA on follow-up data review identifies patients who are from two- to three-fold more likely to experience an AF episode, according to various thresholds of daily AF burden.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Insuficiencia Cardíaca , Síndromes de la Apnea del Sueño , Algoritmos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Insuficiencia Cardíaca/complicaciones , Humanos , Síndromes de la Apnea del Sueño/complicaciones , Síndromes de la Apnea del Sueño/diagnóstico , Síndromes de la Apnea del Sueño/terapia
16.
Europace ; 24(2): 234-244, 2022 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-34392336

RESUMEN

AIMS: We developed and validated an algorithm for prediction of heart failure (HF) hospitalizations using remote monitoring (RM) data transmitted by implanted defibrillators. METHODS AND RESULTS: The SELENE HF study enrolled 918 patients (median age 69 years, 81% men, median ejection fraction 30%) with cardiac resynchronization therapy (44%), dual-chamber (38%), or single-chamber defibrillators with atrial diagnostics (18%). To develop a predictive algorithm, temporal trends of diurnal and nocturnal heart rates, ventricular extrasystoles, atrial tachyarrhythmia burden, heart rate variability, physical activity, and thoracic impedance obtained by daily automatic RM were combined with a baseline risk-stratifier (Seattle HF Model) into one index. The primary endpoint was the first post-implant adjudicated HF hospitalization. After a median follow-up of 22.5 months since enrolment, patients were randomly allocated to the algorithm derivation group (n = 457; 31 endpoints) or algorithm validation group (n = 461; 29 endpoints). In the derivation group, the index showed a C-statistics of 0.89 [95% confidence interval (CI): 0.83-0.95] with 2.73 odds ratio (CI 1.98-3.78) for first HF hospitalization per unitary increase of index value (P < 0.001). In the validation group, sensitivity of predicting primary endpoint was 65.5% (CI 45.7-82.1%), median alerting time 42 days (interquartile range 21-89), and false (or unexplained) alert rate 0.69 (CI 0.64-0.74) [or 0.63 (CI 0.58-0.68)] per patient-year. Without the baseline risk-stratifier, the sensitivity remained 65.5% and the false/unexplained alert rates increased by ≈10% to 0.76/0.71 per patient-year. CONCLUSION: With the developed algorithm, two-thirds of first post-implant HF hospitalizations could be predicted timely with only 0.7 false alerts per patient-year.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Anciano , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Hospitalización , Humanos , Masculino , Volumen Sistólico
17.
Pacing Clin Electrophysiol ; 45(6): 807-810, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-33720392

RESUMEN

In the era of coronavirus disease 2019 (COVID-19), the management of cardiac implantable electronic devices infections with concomitant viral infection has not been completely defined yet. In this explorable context, we report the first experience of a Cardiac resynchronization therapy with defibrillator (CRT-D) implantation after transvenous lead extraction for endocarditis in a COVID-19 patient. We describe both the measures and procedures implemented to reduce the cross-infection in the operating room and our clinical practice to improving procedure effectiveness on patient care.


Asunto(s)
COVID-19 , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Endocarditis , Cardiopatías , Dispositivos de Terapia de Resincronización Cardíaca , Remoción de Dispositivos/métodos , Humanos , Estudios Retrospectivos , SARS-CoV-2 , Resultado del Tratamiento
18.
J Cardiovasc Electrophysiol ; 32(6): 1712-1723, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33969569

RESUMEN

INTRODUCTION: Comparison data on management of device-related complications and their impact on patient outcome and healthcare utilization between subcutaneous implantable cardioverter-defibrillator (S-ICD) and transvenous ICD (TV-ICD) are lacking. We designed this prospective, multicentre, observational registry to compare the rate, nature, and impact of long-term device-related complications requiring surgical revision on patient outcome and healthcare utilization between patients undergoing S-ICD or TV-ICD implantation. METHODS AND RESULTS: A total of 1099 consecutive patients who underwent S-ICD or TV-ICD implantation were enrolled. Propensity matching for baseline characteristics yielded 169 matched pairs. Rate, nature, management, and impact on patient outcome of device-related complications were analyzed and compared between two groups. During a mean follow-up of 30 months, device-related complications requiring surgical revision were observed in 20 patients: 3 in S-ICD group (1.8%) and 17 in TV-ICD group (10.1%; p = .002). Compared with TV-ICD patients, S-ICD patients showed a significantly lower risk of lead-related complications (0% vs. 5.9%; p = .002) and a similar risk of pocket-related complications (0.6 vs. 2.4; p = .215) and device infection (0.6% vs. 1.2%; p = 1.000). Complications observed in S-ICD patients resulted in a significantly lower number of complications-related rehospitalizations (median 0 vs. 1; p = .013) and additional hospital treatment days (1.0 ± 1.0 vs. 6.5 ± 4.4 days; p = .048) compared with TV-ICD patients. CONCLUSIONS: Compared with TV-ICD, S-ICD is associated with a lower risk of complications, mainly due to a lower risk of lead-related complications. The management of S-ICD complications requires fewer and shorter rehospitalizations.


Asunto(s)
Desfibriladores Implantables , Desfibriladores Implantables/efectos adversos , Humanos , Aceptación de la Atención de Salud , Estudios Prospectivos , Reoperación , Resultado del Tratamiento
19.
J Cardiovasc Electrophysiol ; 32(6): 1695-1703, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33969578

RESUMEN

BACKGROUND: The traditional technique for subcutaneous implantable cardioverter defibrillator (S-ICD) implantation involves three incisions and a subcutaneous (SC) pocket. An intermuscular (IM) 2-incision technique has been recently adopted. AIMS: We assessed acute defibrillation efficacy (DE) of S-ICD (DE ≤65 J) according to the implantation technique. METHODS: We analyzed consecutive patients who underwent S-ICD implantation and DE testing at 53 Italian centers. Regression analysis was used to determine the association between DFT and implantation technique. RESULTS: A total of 805 patients were enrolled. Four groups were assessed: IM + 2 incisions (n = 546), SC + 2 incisions (n = 133), SC + 3 incisions (n = 111), and IM + 3 incisions (n = 15). DE was ≤65 J in 782 (97.1%) patients. Patients with DE ≤65 J showed a trend towards lower body mass index (25.1 vs. 26.5; p = .12), were less frequently on antiarrhythmic drugs (13% vs. 26%; p = .06) and more commonly underwent implantation with the 2-incision technique (85% vs. 70%; p = .04). The IM + 2-incision technique showed the lowest defibrillation failure rate (2.2%) and shock impedance (66 Ohm, interquartile range: 57-77). On multivariate analysis, the 2-incision technique was associated with a lower incidence of shock failure (hazard ratio: 0.305; 95% confidence interval: 0.102-0.907; p = .033). Shock impedance was lower with the IM than with the SC approach (66 vs. 70 Ohm p = .002) and with the 2-incision than the 3-incision technique (67 vs. 72 Ohm; p = .006). CONCLUSIONS: In a large population of S-ICD patients, we observed a high defibrillation success rate. The IM + 2-incision technique provides lower shock impedance and a higher likelihood of successful defibrillation.


Asunto(s)
Desfibriladores Implantables , Índice de Masa Corporal , Cardioversión Eléctrica/efectos adversos , Impedancia Eléctrica , Humanos , Implantación de Prótesis/efectos adversos , Tejido Subcutáneo , Resultado del Tratamiento
20.
J Cardiovasc Electrophysiol ; 32(9): 2528-2535, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34252991

RESUMEN

INTRODUCTION: Factors influencing malignant arrhythmia onset are not fully understood. We explored the circadian periodicity of ventricular arrhythmias (VAs) in patients with implantable cardioverter and cardiac resynchronization defibrillators (ICD/CRT-D). METHODS: Time, morphology (monomorphic/polymorphic), and mode of termination (anti-tachycardia pacing [ATP] or shock) of VAs stored in a database of remote monitoring data were adjudicated. Episodes were grouped in six 4-h timeslots from 00:00 to 24:00. Circadian distributions and adjusted marginal odds ratios (ORs), with 95% confidence interval (CI), were analyzed using mixed-effect models and logit generalized estimating equations, respectively, to account for within-subject correlation of multiple episodes. RESULTS: Among 1303 VA episodes from 446 patients (63% ICD and 37% CRT-D), 120 (9%) self-extinguished, and 842 (65%) were terminated by ATP, 343 (26%) by shock. VAs clustered from 08:00 to 16:00 with 44% of episodes, as compared with 22% from 00:00 to 08:00 (p < .001) and 34% from 16:00 to 24:00 (p = .005). Episodes were more likely to be polymorphic at night with an adjusted marginal OR of 1.66 (CI, 1.15-2.40; p = .007) at 00:00-04:00 versus other timeslots. Episodes were less likely to be terminated by ATP in the 00:00-04:00 (success-to-failure ratio, 0.67; CI, 0.46-0.98; p = .039) and 08:00-12:00 (0.70; CI, 0.51-0.96; p = .02) timeslots, and most likely to be terminated by ATP between 12:00 and 16:00 (success-to-failure ratio 1.42; CI, 1.06-1.91; p = .02). CONCLUSION: VAs did not distribute uniformly over the 24 h, with a majority of episodes occurring from 08:00 to 16:00. Nocturnal episodes were more likely to be polymorphic. The efficacy of ATP depended on the time of delivery.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Taquicardia Ventricular , Arritmias Cardíacas , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA