1.
J Arthroplasty ; 33(9): 3030-3037, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29754982

RESUMEN

BACKGROUND: Suboptimal total knee arthroplasty (TKA) position of both femoral and tibial components is thought to be linked with poor clinical outcomes, polyethylene wear and the "unexplained" painful knee arthroplasty. The aim of this study was to better understand the effect of implant orientation on knee implant performance. METHODS: We analyzed 30 retrieved contemporary TKA implants. Implant positioning measurements in the coronal plane were made prior to revision using a diagnostic algorithm, based on 3D computed tomography (CT) images. Each retrieved polyethylene component was imaged using a micro-CT scanner and a high resolution computational 3D model of each component was digitally reconstructed. The difference in thickness between medial and lateral components was calculated. Statistical analysis was performed to investigate the association between component positioning and damage patterns. RESULTS: We found a significant correlation between both the tibiofemoral and femoral angles and difference in thickness between polyethylene compartments: varus angulations were strongly associated with thinner medial compartments, whilst valgus angulations were associated with thinner lateral compartments. Moreover, suboptimal tibiofemoral orientations and tibial component angulations were associated to greater differences in thickness between polyethylene compartments. CONCLUSION: Our study is the first to compare accurate 3D CT measurements of prerevision TKA positioning in the coronal plane with postrevision retrieval analysis from innovative, accurate and highly reliable micro-CT-based method. Our results demonstrate the impact of component positioning on polyethylene damage and helps understanding of the in vivo performance of these implants. LEVEL OF EVIDENCE: III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Tibia/cirugía , Tomografía Computarizada por Rayos X , Adulto , Anciano , Algoritmos , Estudios de Cohortes , Femenino , Fémur/cirugía , Humanos , Imagenología Tridimensional , Rodilla/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Polietileno , Interpretación de Imagen Radiográfica Asistida por Computador , Reproducibilidad de los Resultados , Programas Informáticos , Propiedades de Superficie , Tibia/diagnóstico por imagen , Microtomografía por Rayos X
2.
Bone Joint Res ; 10(7): 388-400, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34235940

RESUMEN

AIMS: The main advantage of 3D-printed, off-the-shelf acetabular implants is the potential to promote enhanced bony fixation due to their controllable porous structure. In this study we investigated the extent of osseointegration in retrieved 3D-printed acetabular implants. METHODS: We compared two groups, one made via 3D-printing (n = 7) and the other using conventional techniques (n = 7). We collected implant details, type of surgery and removal technique, patient demographics, and clinical history. Bone integration was assessed by macroscopic visual analysis, followed by sectioning to allow undecalcified histology on eight sections (~200 µm) for each implant. The outcome measures considered were area of bone attachment (%), extent of bone ingrowth (%), bone-implant contact (%), and depth of ingrowth (%), and these were quantified using a line-intercept method. RESULTS: The two groups were matched for patient sex, age (61 and 63 years), time to revision (30 and 41 months), implant size (54 mm and 52 mm), and porosity (72% and 60%) (p > 0.152). There was no difference in visual bony attachment (p = 0.209). Histological analysis showed greater bone ingrowth in 3D-printed implants (p < 0.001), with mean bone attachment of 63% (SD 28%) and 37% (SD 20%), respectively. This was observed for all the outcome measures. CONCLUSION: This was the first study to investigate osseointegration in retrieved 3D-printed acetabular implants. Greater bone ingrowth was found in 3D-printed implants, suggesting that better osseointegration can be achieved. However, the influence of specific surgeon, implant, and patient factors needs to be considered. Cite this article: Bone Joint Res 2021;10(7):388-400.

3.
J Orthop Surg Res ; 15(1): 157, 2020 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-32306995

RESUMEN

BACKGROUND: Three-dimensional (3D) printing of porous titanium implants is increasing in orthopaedics, promising enhanced bony fixation whilst maintaining design similarities with conventionally manufactured components. Our study is one of the first to non-destructively characterize 3D-printed implants, using conventionally manufactured components as a reference. METHODS: We analysed 16 acetabular cups retrieved from patients, divided into two groups: '3D-printed' (n = 6) and 'conventional' (n = 10). Coordinate-measuring machine (CMM), electron microscopy (SEM) and microcomputed tomography (micro-CT) were used to investigate the roundness of the internal cup surface, the morphology of the backside surface and the morphometric features of the porous structures of the cups, respectively. The amount of bony attachment was also evaluated. RESULTS: CMM analysis showed a median roundness of 19.45 and 14.52 µm for 3D-printed and conventional cups, respectively (p = 0.1114). SEM images revealed partially molten particles on the struts of 3D-printed implants; these are a by-product of the manufacturing technique, unlike the beads shown by conventional cups. As expected, porosity, pore size, strut thickness and thickness of the porous structure were significantly higher for 3D-printed components (p = 0.0002), with median values of 72.3%, 915 µm, 498 µm and 1.287 mm (p = 0.0002). The median values of bony attachment were 84.9% and 69.3% for 3D-printed and conventional cups, respectively (p = 0.2635). CONCLUSION: 3D-printed implants are designed to be significantly more porous than some conventional components, as shown in this study, whilst still exhibiting the same shape and size. We found differences in the surface morphologies of the groups, related to the different manufacturing methods; a key finding was the presence of partially molten particles on the 3D-printed cups.


Asunto(s)
Acetábulo/anatomía & histología , Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera , Acetábulo/diagnóstico por imagen , Anciano , Artroplastia de Reemplazo de Cadera/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Impresión Tridimensional , Diseño de Prótesis , Microtomografía por Rayos X
4.
J Biomed Mater Res B Appl Biomater ; 108(5): 1779-1789, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-31769198

RESUMEN

The use of three-dimensional (3D) printing to manufacture off-the-shelf titanium acetabular cups for hip arthroplasty has increased; however, the impact of this manufacturing technology is yet not fully understood. Although several studies have described the presence of structural cavities in 3D printed parts, there has been no analysis of full postproduction acetabular components. The aim of this study was to investigate the effect of 3D printing on the material structure of acetabular implants, first comparing different designs of 3D printed cups, second comparing 3D printed with conventionally manufactured cups. Two of the 3D printed cups were produced using electron beam melting (EBM), one using laser rapid manufacturing (LRM). The investigation was performed using X-ray microcomputed tomography, imaging both the entire cups and samples sectioned from different regions of each cup. All 3D printed cups showed evidence of structural cavities; these were uniformly distributed in the volume of the samples and exhibited a prevalent spherical shape. The LRM-manufactured cup had significantly higher cavity density (p = .0286), with a median of 21 cavities/mm3 compared to 3.5 cavities/mm3 for EBM cups. However, the cavity size was similar, with a median of 20 µm (p = .7385). The conventional cups showed a complete absence of distinguishable cavities. The presence of cavities is a known limitation of the 3D printing technology; however, it is noteworthy that we found them in orthopedic implants used in patients. Although this may impact their mechanical properties, to date, 3D printed cups have not been reported to encounter such failures.


Asunto(s)
Acetábulo/metabolismo , Titanio/metabolismo , Artroplastia de Reemplazo de Cadera , Análisis de Falla de Equipo , Prótesis de Cadera , Humanos , Impresión Tridimensional , Prótesis e Implantes , Tomografía Computarizada por Rayos X
5.
3D Print Med ; 5(1): 15, 2019 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-31696334

RESUMEN

BACKGROUND: The design freedom allowed by three-dimensional (3D) printing enables the production of acetabular off-the-shelf cups with complex porous structures. The only studies on these designs are limited to clinical outcomes. Our aim was to analyse and compare the designs of different 3D printed cups from multiple manufacturers (Delta TT, Trident II Tritanium and Mpact 3D Metal). METHODS: We analysed the outer surface of the cups using scanning electron microscopy (SEM) and assessed clinically relevant morphometric features of the lattice structures using micro-computed tomography (micro-CT). Dimensions related to the cup wall (solid, lattice and overall thickness) were also measured. Roundness and roughness of the internal cup surface were analysed with coordinate measuring machine (CMM) and optical profilometry. RESULTS: SEM showed partially molten titanium beads on all cups, significantly smaller on Trident II (27 µm vs ~ 70 µm, p < 0.0001). We found a spread of pore sizes, with median values of 0.521, 0.841 and 1.004 mm for Trident II, Delta TT and Mpact, respectively. Trident II was also significantly less porous (63%, p < 0.0001) than the others (Delta TT 72.3%, Mpact 76.4%), and showed the thinnest lattice region of the cup wall (1.038 mm, p < 0.0001), while Mpact exhibited the thicker solid region (4.880 mm, p < 0.0044). Similar roundness and roughness of the internal cup surfaces were found. CONCLUSION: This was the first study to compare the designs of different 3D printed cups. A variability in the morphology of the outer surface of the cups and lattice structures was found. The existence of titanium beads on 3D printed parts is a known by-product of the manufacturing process; however, their prevalence on acetabular cups used in patients is an interesting finding, since these beads may potentially be released in the body.