Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Adv Healthc Mater ; 12(17): e2202673, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36849872

RESUMEN

Advanced interfacial engineering has the potential to enable the successful realization of three features that are particularly important for a variety of healthcare applications: wettability control, antimicrobial activity to reduce infection risks, and sensing of physiological parameters. Here, a sprayable multifunctional triboelectric coating is exploited as a nontoxic, ultrathin tactile sensor that can be integrated directly on the fingertips of surgical gloves. The coating is based on a polymer blend mixed with zinc oxide (ZnO) nanoparticles, which enables antifouling and antibacterial properties. Additionally, the nanocomposite is superhydrophobic (self-cleaning) and is not cytotoxic. The coating is also triboelectric and can be applied directly onto surgical gloves with printed electrodes. The sensorized gloves so obtained enable mechanical energy harvesting, force sensing, and detection of materials stiffness changes directly from fingertip, which may complement proprioceptive feedback for clinicians. Just as importantly, the sensors also work with a second glove on top offering better reassurance regarding sterility in interventional procedures. As a case study of clinical use for stiffness detection, the sensors demonstrate successful detection of pig anal sphincter injury ex vivo. This may lead to improving the accuracy of diagnosing obstetric anal sphincter injury, resulting in prompt repair, fewer complications, and improved quality of life.


Asunto(s)
Infertilidad , Nanocompuestos , Animales , Porcinos , Guantes Quirúrgicos , Tecnología Háptica , Calidad de Vida , Nanocompuestos/química
2.
Mater Horiz ; 10(8): 3124-3134, 2023 07 31.
Artículo en Inglés | MEDLINE | ID: mdl-37221946

RESUMEN

Triboelectric nanogenerators (TENGs) have emerged as a promising green technology to efficiently harvest otherwise wasted mechanical energy from the environment and human activities. However, cost-effective and reliably performing TENGs require rational integration of triboelectric materials, spacers, and electrodes. The present work reports for the first time the use of oxydation-resistant pure copper nanowires (CuNWs) as an electrode to develop a flexible, and inexpensive TENG through a potentially scalable approach involving vacuum filtration and lactic acid treatment. A ∼6 cm2 device yields a remarkable open circuit voltage (Voc) of 200 V and power density of 10.67 W m-2 under human finger tapping. The device is robust, flexible and noncytotoxic as assessed by stretching/bending maneuvers, corrosion tests, continuous operation for 8000 cycles, and biocompatibility tests using human fibroblast cells. The device can power 115 light emitting diodes (LEDs) and a digital calculator; sense bending and motion from the human hand; and transmit Morse code signals. The robustness, flexibility, transparency, and non-cytotoxicity of the device render it particularly promising for a wide range of energy harvesting and advanced healthcare applications, such as sensorised smart gloves for tactile sensing, material identification and safer surgical intervention.


Asunto(s)
Cobre , Nanocables , Humanos , Fenómenos Físicos , Actividades Humanas , Electrodos
3.
Neurosurgery ; 92(3): 639-646, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36729776

RESUMEN

BACKGROUND: Measuring intraoperative forces in real time can provide feedback mechanisms to improve patient safety and surgical training. Previous force monitoring has been achieved through the development of specialized and adapted instruments or use designs that are incompatible with neurosurgical workflow. OBJECTIVE: To design a universal sensorised surgical glove to detect intraoperative forces, applicable to any surgical procedure, and any surgical instrument in either hand. METHODS: We created a sensorised surgical glove that was calibrated across 0 to 10 N. A laboratory experiment demonstrated that the sensorised glove was able to determine instrument-tissue forces. Six expert and 6 novice neurosurgeons completed a validated grape dissection task 20 times consecutively wearing the sensorised glove. The primary outcome was median and maximum force (N). RESULTS: The sensorised glove was able to determine instrument-tissue forces reliably. The average force applied by experts (2.14 N) was significantly lower than the average force exerted by novices (7.15 N) ( P = .002). The maximum force applied by experts (6.32 N) was also significantly lower than the maximum force exerted by novices (9.80 N) ( P = .004). The sensorised surgical glove's introduction to operative workflow was feasible and did not impede on task performance. CONCLUSION: We demonstrate a novel and scalable technique to detect forces during neurosurgery. Force analysis can provide real-time data to optimize intraoperative tissue forces, reduce the risk of tissue injury, and provide objective metrics for training and assessment.


Asunto(s)
Neurocirugia , Humanos , Guantes Quirúrgicos , Procedimientos Neuroquirúrgicos , Competencia Clínica
4.
Front Surg ; 10: 1185516, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37325417

RESUMEN

Background and objectives: In recent decades, the rise of endovascular management of aneurysms has led to a significant decline in operative training for surgical aneurysm clipping. Simulation has the potential to bridge this gap and benchtop synthetic simulators aim to combine the best of both anatomical realism and haptic feedback. The aim of this study was to validate a synthetic benchtop simulator for aneurysm clipping (AneurysmBox, UpSurgeOn). Methods: Expert and novice surgeons from multiple neurosurgical centres were asked to clip a terminal internal carotid artery aneurysm using the AneurysmBox. Face and content validity were evaluated using Likert scales by asking experts to complete a post-task questionnaire. Construct validity was evaluated by comparing expert and novice performance using the modified Objective Structured Assessment of Technical Skills (mOSATS), developing a curriculum-derived assessment of Specific Technical Skills (STS), and measuring the forces exerted using a force-sensitive glove. Results: Ten experts and eighteen novices completed the task. Most experts agreed that the brain looked realistic (8/10), but far fewer agreed that the brain felt realistic (2/10). Half the expert participants (5/10) agreed that the aneurysm clip application task was realistic. When compared to novices, experts had a significantly higher median mOSATS (27 vs. 14.5; p < 0.01) and STS score (18 vs. 9; p < 0.01); the STS score was strongly correlated with the previously validated mOSATS score (p < 0.01). Overall, there was a trend towards experts exerting a lower median force than novices, however, these differences were not statistically significant (3.8 N vs. 4.0 N; p = 0.77). Suggested improvements for the model included reduced stiffness and the addition of cerebrospinal fluid (CSF) and arachnoid mater. Conclusion: At present, the AneurysmBox has equivocal face and content validity, and future versions may benefit from materials that allow for improved haptic feedback. Nonetheless, it has good construct validity, suggesting it is a promising adjunct to training.

5.
Sci Rep ; 12(1): 13657, 2022 08 11.
Artículo en Inglés | MEDLINE | ID: mdl-35953582

RESUMEN

Milk adulteration is a common problem in developing countries, and it can lead to fatal diseases in humans. Despite several studies to identify different adulterants in milk samples, the effects of multiple adulterants remain unexplored. In this work, a three-dimensional (3D) paper-based microfluidic device is designed and fabricated to simultaneously detect multiple chemical adulterants in milk. This device comprises a top cover, a bottom cover, and a middle layer composed of transportation and a detection zone. By making cuts on the middle layer's support, the device's flow path is characterised by optimum and uniform velocity. For the first time, seven adulterants (urea, detergents, soap, starch, hydrogen peroxide, sodium-hydrogen-carbonate, and salt) are detected in the milk sample simultaneously with specificity evaluation and detailed color interference analysis. Only 1-2 mL of sample volume is required to detect 7 adulterants at one time. We have used only 10 [Formula: see text]L of the reagent's volume for the colorimetric reaction and found the results within a few seconds. Observation reveals that the limit of detection (LOD) of the adulterants lies in the range between [Formula: see text] (vol./vol.) to [Formula: see text] (vol./vol.) using the colorimetric detection technique. The unknown quantity of the added adulterants is measured using the calibration curves obtained from the experiments results. The repeatability and reproducibility of the process, sensitivity, and the linear range of detection of the calibration curves and the statistical study of the color intensity data are thoroughly analysed herein. In any resource-limited setting, this simple, portable, and user-friendly 3D microfluidic device is expected to be used for testing liquid foods before consumption.


Asunto(s)
Contaminación de Alimentos , Leche , Animales , Calibración , Contaminación de Alimentos/análisis , Humanos , Leche/química , Reproducibilidad de los Resultados , Urea/análisis
6.
J Phys Commun ; 7(6): 065008, 2022 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-37398924

RESUMEN

Upconverting particles like Yb and Er-doped NaYF4 are known to heat up after illumination with light at pump wavelength due to inefficient upconversion processes. Here we show that NaYF4 particles which have been co-doped not only with Yb and Er but also Fe improves the photothermal conversion efficiency. In addition, we show for the first time that alternating magnetic fields also heat up the ferromagnetic particles. Thereafter we show that a combination of optical and magnetic stimuli significantly increases the heat generated by the particles.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA