Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Ophthalmic Physiol Opt ; 44(6): 1301-1308, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38953568

RESUMEN

PURPOSE: The prevalence of myopia in Scandinavia tends to be lower than in other parts of the world. This study aimed to investigate the incidence of myopia and its predictors in Swedish children to characterise this trend. METHODS: A 2-year longitudinal study was conducted following a cohort of schoolchildren aged 8-16 years. Myopia was defined as a spherical equivalent refraction (SER) ≤ -0.50 D. The study enrolled 128 participants, 70 (55%) females with a mean age of 12.0 years (SD = 2.4). RESULTS: The cumulative incidence of myopia during the follow-up period was 5.5%, and the incidence rate of myopia was 3.2 cases per 100 person-years. Participants with myopia at baseline exhibited a faster increase in refractive error during the follow-up period. Likewise, participants with two myopic parents exhibited a more marked change towards myopia, regardless of their initial refractive error. CONCLUSION: In the current study, similar to prevalence, the incidence of myopia was low when compared with other parts of the world. These results lead us to formulate a new hypothesis that the normal emmetropisation process may be protected by low educational pressure practised in Sweden during early childhood. Further research is necessary to test this new hypothesis.


Asunto(s)
Miopía , Refracción Ocular , Humanos , Suecia/epidemiología , Femenino , Miopía/epidemiología , Miopía/fisiopatología , Niño , Masculino , Incidencia , Adolescente , Refracción Ocular/fisiología , Prevalencia , Estudios Longitudinales , Estudios de Seguimiento
2.
Ophthalmic Physiol Opt ; 42(3): 644-652, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35156728

RESUMEN

PURPOSE: Markers for the relationships between structural and microvasculature measures given by optical coherence tomography angiography are necessary to increase the diagnostic and prognostic value of this technique. The aim of this study was to investigate relationships between structural and microvasculature measures around the fovea in healthy eyes of healthy children. METHODS: Observational cross-sectional study involving children aged 8-17 years, born at full-term, with no eye disease. The better of two 3 × 3 mm macular scans obtained with a Cirrus 5000HD-OCT was analysed. Images were corrected for lateral magnification errors. Vessel density and perfusion were measured with ImageJ/Fiji software for the superficial capillary plexus. Structural measures including foveal and macular thicknesses were performed manually. RESULTS: The sample included 86 participants, 51 (59%) females. Mean age was 12.4 years (SD = 2.5); mean best-corrected acuity was -0.10 logMAR (SD = 0.09); mean refractive error was +0.59 D (SD = 1.3) and mean axial length was 23.1 mm (SD = 0.86). Mean area of the foveal avascular zone (AFAZ) was 0.20 mm2 (SD = 0.88); median fovea-to-macula thickness ratio (FMTR) was 0.63 (IQR = 0.08); mean central vessel density was 12.42 mm-1 (SD = 2.78) and mean central perfusion was 38.66% (SD = 3.83). AFAZ was correlated with central vessel density (p < 0.001), perfusion (p < 0.001), foveal thickness (p < 0.001) and FMTR (p < 0.001). Central vessel density was correlated with foveal thickness (p < 0.001) and FMTR, (p = 0.01). Central perfusion was correlated with foveal thickness (p < 0.001) and FMTR, (p = 0.003). CONCLUSION: In this study, foveal thickness, FMTR and foveal microvasculature measurements were correlated. Clinicians need to be aware that shallow foveal pits and persistent foveal microvasculature are likely to occur in optical coherence tomography angiography images. In healthy eyes from healthy children, an atypical high FMTR and a small AFAZ may be associated with incomplete foveal development. The mechanism and functional implications of this remain unknown.


Asunto(s)
Fóvea Central , Vasos Retinianos , Adolescente , Niño , Preescolar , Estudios Transversales , Femenino , Angiografía con Fluoresceína/métodos , Fondo de Ojo , Humanos , Microvasos/diagnóstico por imagen , Vasos Retinianos/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Agudeza Visual
3.
J Optom ; 16(1): 20-29, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-35022155

RESUMEN

PURPOSE: The aim of this study was to compare central and peripheral refraction using an open view Shin-Nippon NVision-K 5001 autorefractor and an open view COAS-HD VR aberrometer in young children. METHODS: Cycloplegic central and peripheral autorefraction was measured in the right eye of 123 children aged 8 to 16 years. Three measurements each were obtained with both Shin-Nippon NVision-K 5001 autorefractor and COAS-HD VR aberrometer along the horizontal visual field up to 30° (nasal and temporal) in 10° steps. The refraction from the autorefractor was compared with aberrometer refraction for pupil analysis diameters of 2.5-mm and 5.0-mm. RESULTS: The Shin-Nippon was 0.30 D more hyperopic than COAS-HD VR at 2.5-mm pupil and 0.50 D more hyperopic than COAS-HD VR at 5-mm pupil for central refraction. For both pupil sizes, the 95% limits of agreement were approximately 0.50 D for central refraction, and limits were wider in the nasal visual field compared to the temporal visual field. The mean difference for both J0 and J45 were within 0.15 D and the 95% limits of agreement within 0.90 D across the horizontal visual field. CONCLUSION: Defocus components were similar between the Shin-Nippon autorefractor and the COAS-HD VR aberrometer with a 2.5-mm pupil for most visual field angles. However, there was a significant difference in defocus component between the Shin-Nippon autorefractor and the COAS-HD VR aberrometer with a 5.0-mm pupil, wherein the autorefractor measured more hyperopia. The astigmatic components J0 and J45 were similar between instruments for both central and peripheral refraction.


Asunto(s)
Hiperopía , Refracción Ocular , Humanos , Niño , Preescolar , Pruebas de Visión , Midriáticos , Pupila
4.
Clin Exp Optom ; 104(5): 595-601, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33689658

RESUMEN

Clinical relevance: Investigation of refractive errors amongst Swedish schoolchildren will help identify risk factors associated with myopia development.Background: Genetic and hereditary aspects have been linked with the development of myopia. Nevertheless, in the case of 'school myopia' some authors suggest that environmental factors may affect gene expression, causing school myopia to soar. Additional understanding about which environmental factors play a relevant role can be gained by studying refractive errors in countries like Sweden, where prevalence of myopia is expected to be low.Methods: Swedish schoolchildren aged 8-16 years were invited to participate. Participants underwent an eye examination, including cycloplegic refraction and axial length (AL) measurements. Predictors such as time spent in near work, outdoor activities and parental myopia were obtained using a questionnaire. Myopia was defined as spherical equivalent refraction (SER) ≤ -0.50D and hyperopia as SER ≥ +0.75D.Results: A total of 128 children (70 females and 58 males) participated in this study with mean age of 12.0 years (SD = 2.4). Based on cycloplegic SER of the right eye, the distribution of refractive errors was: hyperopia 48.0% (CI95 = 38.8-56.7), emmetropia 42.0% (CI95 = 33.5-51.2) and myopia 10.0%. (CI95 = 4.4-14.9). The mean AL was 23.1 mm (SD = 0.86), there was a correlation between SER and AL, r = -0.65 (p < 0.001). Participants with two myopic parents had higher myopia and increased axial length than those with one or no myopic parents. The mean time spent in near work, outside of school, was 5.3 hours-per-day (SD = 3.1), and mean outdoor time reported was 2.6 hours-per-day (SD = 2.2) for all the participants. The time spent in near work and outdoor time were different for different refractive error categories.Conclusion: The prevalence of myopia amongst Swedish schoolchildren is low. Hereditary and environmental factors are associated with refractive error categories. Further studies with this sample are warranted to investigate how refractive errors and environmental factors interact over time.


Asunto(s)
Hiperopía , Miopía , Errores de Refracción , Longitud Axial del Ojo , Niño , Femenino , Humanos , Hiperopía/epidemiología , Hiperopía/genética , Recién Nacido , Masculino , Miopía/epidemiología , Miopía/genética , Refracción Ocular , Errores de Refracción/epidemiología , Errores de Refracción/genética , Suecia/epidemiología
5.
J. optom. (Internet) ; 16(1)January - March 2023. ilus, tab, graf
Artículo en Inglés | IBECS (España) | ID: ibc-214427

RESUMEN

Purpose: The aim of this study was to compare central and peripheral refraction using an open view Shin-Nippon NVision-K 5001 autorefractor and an open view COAS-HD VR aberrometer in young children.MethodsCycloplegic central and peripheral autorefraction was measured in the right eye of 123 children aged 8 to 16 years. Three measurements each were obtained with both Shin-Nippon NVision-K 5001 autorefractor and COAS-HD VR aberrometer along the horizontal visual field up to 30° (nasal and temporal) in 10° steps. The refraction from the autorefractor was compared with aberrometer refraction for pupil analysis diameters of 2.5-mm and 5.0-mm.ResultsThe Shin-Nippon was 0.30 D more hyperopic than COAS-HD VR at 2.5-mm pupil and 0.50 D more hyperopic than COAS-HD VR at 5-mm pupil for central refraction. For both pupil sizes, the 95% limits of agreement were approximately 0.50 D for central refraction, and limits were wider in the nasal visual field compared to the temporal visual field. The mean difference for both J0 and J45 were within 0.15 D and the 95% limits of agreement within 0.90 D across the horizontal visual field.ConclusionDefocus components were similar between the Shin-Nippon autorefractor and the COAS-HD VR aberrometer with a 2.5-mm pupil for most visual field angles. However, there was a significant difference in defocus component between the Shin-Nippon autorefractor and the COAS-HD VR aberrometer with a 5.0-mm pupil, wherein the autorefractor measured more hyperopia. The astigmatic components J0 and J45 were similar between instruments for both central and peripheral refraction. (AU)


Asunto(s)
Humanos , Niño , Adolescente , Hiperopía , Midriáticos , Estudiantes , Preescolar , Refracción Ocular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA