Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Opt Express ; 29(21): 34781-34796, 2021 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-34809260

RESUMEN

This paper proposes a passive optical brightening element design, a non-axisymmetric freeform lens (NAFL), arranged and assembled on a traditional traffic sign. NAFL is the first optical design which can effectively solve the traffic problem that direct sunlight affects the driver's inability to look directly at the traffic sign. The NAFL can converge the sunlight behind the traffic sign and diverge forward to 150 meters away. In this way, the NAFL array combinations on the traffic sign can directly rely on sunlight as image information pixels. According to the simulation, the optical efficiency of the NAFL can be as high as 81.5%. Besides, the angular tolerance is also analyzed to evaluate the working hours of the NAFL. Finally, we made the prototype and proved that such passive brightening components could effectively improve the traffic sign's visibility in harsh sunlight.

2.
Opt Express ; 20(13): 14584-95, 2012 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-22714520

RESUMEN

In this paper, a metal layer assisted guide mode resonance (MaGMR) device with high sensitivity is proposed for bioanalytical applications and its functioning is experimentally proved. We find that the reflection spectra present a unique inversed response. The resonance mechanism is also discussed. Numerical calculation results indicate that the high sensitivity performance of MaGMR comes from the strongly asymmetric resonance modal profile and low propagation angle inside the waveguide. There is a one-fold enhancement of the evanescent wave in the analytes region compared to typical GMR. According to the experimental results, the proposed MaGMR achieved a bulk sensitivity of 376.78 nm/RIU in fundamental TM mode resonating at 0.809 µm with the first diffraction angle. Experiment results show a 264.78% enhancement in the sensitivity compared to that of the typical GMR sensor in the same resonance conditions of TM mode.


Asunto(s)
Técnicas Biosensibles/instrumentación , Metales/química , Fotometría/instrumentación , Refractometría/instrumentación , Resonancia por Plasmón de Superficie/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo
3.
Sensors (Basel) ; 11(9): 8953-65, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22164115

RESUMEN

Recent developments in aptamers have led to their widespread use in analytical and diagnostic applications, particularly for biosensing. Previous studies have combined aptamers as ligands with various sensors for numerous applications. However, merging the aptamer developments with guided mode resonance (GMR) devices has not been attempted. This study reports an aptasensor based home built GMR device. The 29-mer thrombin aptamer was immobilized on the surface of a GMR device as a recognizing ligand for thrombin detection. The sensitivity reported in this first trial study is 0.04 nm/µM for thrombin detection in the concentration range from 0.25 to 1 µM and the limit of detection (LOD) is 0.19 µM. Furthermore, the binding affinity constant (Ka) measured is in the range of 10(6) M(-1). The investigation has demonstrated that such a GMR aptasensor has the required sensitivity for the real time, label-free, in situ detection of thrombin and provides kinetic information related to the binding.


Asunto(s)
Trombina/análisis , Técnicas Biosensibles , Cinética , Límite de Detección
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA