Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Radiol Bras ; 53(3): 148-154, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32587421

RESUMEN

OBJECTIVE: To compare automated and manual magnetic resonance imaging protocols for estimating liver iron concentrations at 1.5 T. MATERIALS AND METHODS: Magnetic resonance imaging examination of the liver was performed in 53 patients with clinically suspected hepatic iron overload and in 21 control subjects. Liver iron concentrations were then estimated by two examiners who were blinded to the groups. The examiners employed automated T2* and T1 mapping, as well as manual T2* and signal-intensity-ratio method. We analyzed accuracy by using ROC curves. Interobserver and intraobserver agreement were analyzed by calculating two-way intraclass correlation coefficients. RESULTS: The area under the ROC curve (to discriminate between patients and controls) was 0.912 for automated T2* mapping, 0.934 for the signal-intensity-ratio method, 0.908 for manual T2*, and 0.80 for T1 mapping, the last method differing significantly from the other three. The level of interobserver and intraobserver agreement was good (intraclass correlation coefficient, 0.938-0.998; p < 0.05). Correlations involving T1 mapping, although still significant, were lower. CONCLUSION: At 1.5 T, T2* mapping is a rapid tool that shows promise for the diagnosis of liver iron overload, whereas T1 mapping shows less accuracy. The performance of T1 mapping is poorer than is that of T2* methods.


OBJETIVO: Comparar protocolos automatizados e manuais de ressonância magnética para estimar a concentração hepática de ferro em 1,5 T. MATERIAIS E MÉTODOS: Foi realizada ressonância magnética hepática em 53 pacientes com suspeita de sobrecarga de ferro hepática e 21 controles, seguida da estimativa cega da concentração hepática de ferro por dois examinadores usando mapas automáticos T2* e T1, assim como o manual T2* e o método signal-intensity-ratio. O desempenho foi medido usando curvas ROC e a correlação interobservador e intraobservador usando o coeficiente de correlação intraclasse bidirecional. RESULTADOS: O desempenho da curva ROC separando pacientes e controles mostrou áreas sob a curva de 0,912 para o mapa automático T2*, 0,934 para o método signal-intensity-ratio, 0,908 para manual T2* e 0,80 para mapa T1 (este difere significativamente dos outros três métodos). Houve boa correlação interobservador e intraobservador (coeficiente de correlação intraclasse entre 0,938 e 0,998; p < 0,05). Correlações envolvendo o mapa T1, embora ainda significativas, foram menores. CONCLUSÃO: Em 1,5 T, o mapa T2* representa uma nova ferramenta rápida e promissora para avaliar o diagnóstico de sobrecarga de ferro hepática, enquanto o mapa T1 mostrou menor precisão. O desempenho do mapa T1 foi menor que o dos métodos T2*.

2.
Radiol Bras ; 52(3): 182-186, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31210693

RESUMEN

The rupture of an abdominal aortic aneurysm (AAA) is considered a high-risk surgical emergency, given the catastrophic consequences and high mortality rate. The objective of this pictorial essay is to illustrate the radiological signs that indicate rupture or imminent rupture. To that end, we describe cases treated at our facility and present a brief review of the literature on the topic. The clinical diagnosis of imminent AAA rupture can be difficult, because patients are usually asymptomatic or have nonspecific pain complaints. In the subsequent follow-up, it is possible to identify radiological signs that indicate instability or rupture itself and thus change the prognosis. Computed tomography is the modality of choice for evaluating an AAA and abdominal pain in the emergency setting. It is therefore essential that the radiologist immediately identify the imaging findings that indicate AAA rupture or the imminent risk of such rupture.


A ruptura de aneurisma da aorta abdominal (AAA) é considerada uma emergência cirúrgica de altíssimo risco, pelas consequências catastróficas e pelo alto índice de mortalidade. Este ensaio iconográfico tem como objetivo ilustrar os sinais radiológicos que indiquem ruptura ou a sua iminência. Utilizamos casos atendidos no nosso serviço e apresentamos breve revisão bibliográfica acerca do tema. O diagnóstico clínico da iminência de ruptura de AAA pode ser difícil, visto que os pacientes são normalmente assintomáticos ou apresentam queixas álgicas inespecíficas. No controle evolutivo, podem ser identificados sinais radiológicos que indiquem instabilidade ou a própria ruptura e, dessa forma, mudar o prognóstico do paciente. Como a tomografia computadorizada é a modalidade de escolha para a avaliação dos AAAs e da dor abdominal no cenário da emergência, torna-se imprescindível o reconhecimento precoce pelo radiologista dos achados de imagem que indiquem aneurismas rotos ou com risco iminente de ruptura.

3.
Femina ; 48(3): 173-176, mar. 31 2020. ilus
Artículo en Portugués | LILACS | ID: biblio-1095700

RESUMEN

Apesar da melhora no diagnóstico e tratamento, a gravidez ectópica ainda é a principal causa de mortalidade materna no primeiro trimestre da gravidez. Formas raras podem apresentar um desafio diagnóstico e, sem um diagnóstico adequado, a incidência de complicações e a mortalidade materna estão relacionadas a aumento de seus índices. Os termos "gravidez cornual" e "gravidez intersticial" têm sido utilizados de forma inconsistente na literatura, sendo frequentemente usados como sinônimos do termo "gravidez angular". Uma distinção estrita entre essas entidades pode ter implicações clínicas importantes, porque o curso natural, a propedêutica e os resultados diferem entre eles. A ressonância magnética não é o padrão-ouro para o diagnóstico de gravidez ectópica, no entanto possui relevância significativa no diagnóstico de possíveis complicações decorrentes dessa afecção. Nesse contexto, esta revisão aborda a importância da ressonância magnética na distinção dos tipos de gravidez mencionados, ilustrados por meio de casos do nosso serviço.(AU)


Despite the improvement in diagnostics and treatment, ectopic pregnancies are still the main cause of maternal mortality in the first trimester of pregnancy. Rare forms may present a diagnostic challenge and without adequate diagnosis, the incidence of complications and maternal mortality is greatly increased. The terms "cornual pregnancy" and "interstitial pregnancy" have been used inconsistently in the literature, frequently been used as synonyms and even used interchangeably with the term "angular pregnancy". A strict distinction among these entities can have important clinical implications because the natural course, management and outcomes differ among them. Magnetic resonance imaging is not the gold standard for the diagnosis of ectopic pregnancy, however, it can be useful in the diagnosis of complicated presentations of such ailment. In this context, this review highlights the importance of MRI in distinguishing the aforementioned types of pregnancies, illustrated with few cases from our service.(AU)


Asunto(s)
Humanos , Femenino , Embarazo , Embarazo Ectópico/diagnóstico por imagen , Espectroscopía de Resonancia Magnética , Embarazo Angular/diagnóstico por imagen , Embarazo Cornual/diagnóstico por imagen , Embarazo Intersticial/diagnóstico por imagen
4.
Radiol. bras ; Radiol. bras;53(3): 148-154, May-June 2020. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1136074

RESUMEN

Abstract Objective: To compare automated and manual magnetic resonance imaging protocols for estimating liver iron concentrations at 1.5 T. Materials and Methods: Magnetic resonance imaging examination of the liver was performed in 53 patients with clinically suspected hepatic iron overload and in 21 control subjects. Liver iron concentrations were then estimated by two examiners who were blinded to the groups. The examiners employed automated T2* and T1 mapping, as well as manual T2* and signal-intensity-ratio method. We analyzed accuracy by using ROC curves. Interobserver and intraobserver agreement were analyzed by calculating two-way intraclass correlation coefficients. Results: The area under the ROC curve (to discriminate between patients and controls) was 0.912 for automated T2* mapping, 0.934 for the signal-intensity-ratio method, 0.908 for manual T2*, and 0.80 for T1 mapping, the last method differing significantly from the other three. The level of interobserver and intraobserver agreement was good (intraclass correlation coefficient, 0.938-0.998; p < 0.05). Correlations involving T1 mapping, although still significant, were lower. Conclusion: At 1.5 T, T2* mapping is a rapid tool that shows promise for the diagnosis of liver iron overload, whereas T1 mapping shows less accuracy. The performance of T1 mapping is poorer than is that of T2* methods.


Resumo Objetivo: Comparar protocolos automatizados e manuais de ressonância magnética para estimar a concentração hepática de ferro em 1,5 T. Materiais e Métodos: Foi realizada ressonância magnética hepática em 53 pacientes com suspeita de sobrecarga de ferro hepática e 21 controles, seguida da estimativa cega da concentração hepática de ferro por dois examinadores usando mapas automáticos T2* e T1, assim como o manual T2* e o método signal-intensity-ratio. O desempenho foi medido usando curvas ROC e a correlação interobservador e intraobservador usando o coeficiente de correlação intraclasse bidirecional. Resultados: O desempenho da curva ROC separando pacientes e controles mostrou áreas sob a curva de 0,912 para o mapa automático T2*, 0,934 para o método signal-intensity-ratio, 0,908 para manual T2* e 0,80 para mapa T1 (este difere significativamente dos outros três métodos). Houve boa correlação interobservador e intraobservador (coeficiente de correlação intraclasse entre 0,938 e 0,998; p < 0,05). Correlações envolvendo o mapa T1, embora ainda significativas, foram menores. Conclusão: Em 1,5 T, o mapa T2* representa uma nova ferramenta rápida e promissora para avaliar o diagnóstico de sobrecarga de ferro hepática, enquanto o mapa T1 mostrou menor precisão. O desempenho do mapa T1 foi menor que o dos métodos T2*.

5.
Radiol. bras ; Radiol. bras;52(3): 182-186, May-June 2019. graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1012928

RESUMEN

Abstract The rupture of an abdominal aortic aneurysm (AAA) is considered a high-risk surgical emergency, given the catastrophic consequences and high mortality rate. The objective of this pictorial essay is to illustrate the radiological signs that indicate rupture or imminent rupture. To that end, we describe cases treated at our facility and present a brief review of the literature on the topic. The clinical diagnosis of imminent AAA rupture can be difficult, because patients are usually asymptomatic or have nonspecific pain complaints. In the subsequent follow-up, it is possible to identify radiological signs that indicate instability or rupture itself and thus change the prognosis. Computed tomography is the modality of choice for evaluating an AAA and abdominal pain in the emergency setting. It is therefore essential that the radiologist immediately identify the imaging findings that indicate AAA rupture or the imminent risk of such rupture.


Resumo A ruptura de aneurisma da aorta abdominal (AAA) é considerada uma emergência cirúrgica de altíssimo risco, pelas consequências catastróficas e pelo alto índice de mortalidade. Este ensaio iconográfico tem como objetivo ilustrar os sinais radiológicos que indiquem ruptura ou a sua iminência. Utilizamos casos atendidos no nosso serviço e apresentamos breve revisão bibliográfica acerca do tema. O diagnóstico clínico da iminência de ruptura de AAA pode ser difícil, visto que os pacientes são normalmente assintomáticos ou apresentam queixas álgicas inespecíficas. No controle evolutivo, podem ser identificados sinais radiológicos que indiquem instabilidade ou a própria ruptura e, dessa forma, mudar o prognóstico do paciente. Como a tomografia computadorizada é a modalidade de escolha para a avaliação dos AAAs e da dor abdominal no cenário da emergência, torna-se imprescindível o reconhecimento precoce pelo radiologista dos achados de imagem que indiquem aneurismas rotos ou com risco iminente de ruptura.

6.
Radiol. bras ; Radiol. bras;46(5): 307-312, Sep-Oct/2013. tab, graf
Artículo en Inglés | LILACS | ID: lil-690170

RESUMEN

A literature review and pictorial essay were developed to discuss the importance of knowing the main findings and locations of otosclerosis at multidetector computed tomography (MDCT). The authors performed a retrospective review of cases of otosclerosis diagnosed in their institution by means of high resolution multidetector computed tomography. Otosclerosis corresponds to otic capsule dysplasia characterized by metabolic derangement of its endochondral layer. Such condition constitutes a relevant cause of sensorineural hearing loss, affecting about 7% to 10% of the general population. The diagnosis is usually clinical, but imaging methods play a significant role in the anatomical detailing, differential diagnosis, surgical planning and evaluation of postoperative complications. Among such methods, the relevance of MDCT is highlighted. Radiologists should be familiar with the MDCT findings of otosclerosis, as well as with the temporal bone anatomy to assist in the appropriate clinical management of this disease.


Revisão da literatura e ensaio iconográfico foram realizados com o objetivo de discutir a importância do conhecimento das principais características e localizações da otosclerose à tomografia computadorizada multidetectores (TCMD). Foi feita avaliação retrospectiva de casos de otosclerose diagnosticados em nosso serviço, em equipamento multidetectores com técnica de alta resolução. A otosclerose é uma displasia da cápsula ótica, caracterizada pelo desarranjo metabólico de sua camada endocondral. É uma importante causa de perda auditiva neurossensorial, com incidência de cerca de 7% a 10% da população geral. O diagnóstico usualmente é clínico, porém os métodos de imagens são de grande valia para o detalhamento anatômico, diagnóstico diferencial, planejamento cirúrgico e avaliação de complicações pósoperatórias. Dentre esses métodos, deve-se ressaltar o importante papel da TCMD. Os radiologistas devem estar familiarizados com as características da otosclerose, assim como com a anatomia do osso temporal à TCMD, para auxiliar no manejo clínico adequado desta doença.

7.
Radiol. bras ; Radiol. bras;46(6): 372-375, Nov-Dec/2013. graf
Artículo en Inglés | LILACS | ID: lil-699247

RESUMEN

Mucoceles are cystic masses that generally affect the sinuses. It occurs as a result from obstruction of the ostium of a sinus and consequential accumulation of mucus. Frontal and ethmoid sinuses are mostly affected. Usually, the clinical symptoms are insidious, varying with the extent of the affected region. The treatment is surgical and endoscopic surgery is the method of choice in most cases. The present study is aimed at describing the main characteristics of paranasal sinuses mucoceles, demonstrating and illustrating a series of atypical presentations with emphasis on imaging findings.

8.
Radiol. bras ; Radiol. bras;46(2): 101-105, mar.-abr. 2013. ilus, graf
Artículo en Portugués | LILACS | ID: lil-673353

RESUMEN

A maioria das fraturas dos ossos temporais resulta de traumas cranianos bruscos, de alta energia, estando muitas vezes relacionadas a outras fraturas cranianas ou a politraumatismo. As fraturas e os deslocamentos da cadeia ossicular, na orelha média, representam umas das principais complicações das injúrias nos ossos temporais e, por isso, serão abordadas de maneira mais profunda neste artigo. Os outros tipos de injúrias englobam as fraturas labirínticas, fístula dural, paralisia facial e extensão da linha de fratura ao canal carotídeo. A tomografia computadorizada tem papel fundamental na avaliação inicial dos pacientes politraumatizados, pois é capaz de identificar injúrias em importantes estruturas que podem causar graves complicações, como perda auditiva de condução ou neurossensorial, tonturas e disfunções do equilíbrio, fístulas perilinfáticas, paralisia do nervo facial, lesões vasculares, entre outras.


Most temporal bone fractures result from high-energy blunt head trauma, and are frequently related to other skull fractures or to polytrauma. Fractures and displacements of ossicular chain in the middle ear represent some of the main complications of temporal bone injury, and hence they will be more deeply approached in the present article. Other types of injuries include labyrinthine fractures, dural fistula, facial nerve paralysis and extension into the carotid canal. Computed tomography plays a fundamental role in the initial evaluation of polytrauma patients, as it can help to identify important structural injuries that may lead to severe complications such as sensorineural hearing loss, conductive hearing loss, dizziness and balance dysfunction, perilymphatic fistulas, facial nerve paralysis, vascular injury and others.


Asunto(s)
Humanos , Traumatismos Craneocerebrales , Fracturas Craneales , Hueso Temporal , Tomografía Computarizada por Rayos X
9.
Radiol. bras ; Radiol. bras;46(4): 247-251, Jul-Aug/2013. graf
Artículo en Inglés | LILACS | ID: lil-684589

RESUMEN

Middle ear cholesteatoma is a relevant and relatively common disease that may have severe consequences. In the present pictorial essay, the authors have selected illustrative examples of multislice computed tomography and magnetic resonance imaging depicting the main presentations of cholesteatomas, and describing their characteristics, locations, and major complications.


O colesteatoma da orelha média é uma doença importante e relativamente comum, podendo ter sérias consequências. Neste ensaio iconográfico selecionamos exemplos ilustrativos de tomografia computadorizada multislice e ressonância magnética das principais apresentações dos colesteatomas, descrevendo suas características, localizações e principais complicações.

10.
Radiol. bras ; Radiol. bras;46(3): 163-167, May-Jun/2013. graf
Artículo en Inglés | LILACS | ID: lil-681923

RESUMEN

Cochlear implant is the method of choice in the treatment of deep sensorineural hypoacusis, particularly in patients where conventional amplification devices do not imply noticeable clinical improvement. Imaging findings are crucial in the indication or contraindication for such surgical procedure. In the assessment of the temporal bone, radiologists should be familiar with relative or absolute contraindication factors, as well as with factors that might significantly complicate the implantation. Some criteria such as cochlear nerve aplasia, labyrinthine and/or cochlear aplasia are still considered as absolute contraindications, in spite of studies bringing such criteria into question. Cochlear dysplasias constitute relative contraindications, among them labyrinthitis ossificans is highlighted. Other alterations may be mentioned as complicating agents in the temporal bone assessment, namely, hypoplasia of the mastoid process, aberrant facial nerve, otomastoiditis, otosclerosis, dehiscent jugular bulb, enlarged endolymphatic duct and sac. The experienced radiologist assumes an important role in the evaluation of this condition.


O implante coclear é o método de escolha no tratamento da hipoacusia neurossensorial profunda, notadamente nos pacientes em que os aparelhos de amplificação convencionais não implicam melhora clínica notável. Achados de imagem são fatores decisórios na indicação ou contraindicação desse procedimento cirúrgico. Os fatores que contraindicam absoluta ou relativamente, assim como os que podem complicar de forma significativa o implante, devem ser familiares aos radiologistas na avaliação do osso temporal. Alguns critérios ainda são considerados contraindicações absolutas, como a aplasia do nervo coclear, a aplasia da cóclea e/ou labiríntica, apesar de já existirem relatos que questionam ou contradizem esses dois últimos. As contraindicações relativas são as displasias cocleares, destacando a labirintite ossificante. Outros achados podem ser citados como agentes complicadores na avaliação temporal, tais como hipoplasia do processo mastoideo, nervo facial aberrante, otomastoidite, otosclerose, deiscência do bulbo da jugular, alargamento dos ductos e saco endolinfático. O radiologista experiente na avaliação do osso temporal assume papel de destaque no curso dessa doença.

11.
Radiol. bras ; Radiol. bras;46(3): 184-186, May-Jun/2013. graf
Artículo en Inglés | LILACS | ID: lil-681934

RESUMEN

Persistent stapedial artery is a rare congenital anomaly that occurs by a failure in the involution of such artery. Most patients with persistent stapedial artery are asymptomatic. The imaging diagnosis is made principally by means of multidetector computed tomography. In the present case, persistent stapedial artery was an incidental computed tomography finding. The authors discuss the embryogenesis, computed tomography findings and the importance of an early diagnosis of such anomaly.


A artéria estapedial persistente é uma rara anomalia congênita que ocorre por uma falha na sua involução. A maioria dos pacientes com artéria estapedial persistente é assintomática. O diagnóstico de imagem é feito principalmente pela tomografia computadorizada multidetectores. Neste estudo a artéria estapedial persistente foi um achado ocasional no exame tomográfico. São discutidos a embriologia, os achados tomográficos e a importância do seu diagnóstico precoce.

12.
Radiol. bras ; Radiol. bras;45(6): 351-352, out.-dez. 2012. ilus
Artículo en Portugués | LILACS | ID: lil-660797

RESUMEN

A concha nasal média secundária é uma rara variação anatômica na cavidade nasal, descrita pela primeira vez por Khanobthamchai et al. como uma estrutura óssea revestida por partes moles originária da parede lateral do meato médio. Na maioria dos casos relatados na literatura ocorre bilateralmente, sem complicações associadas. Neste artigo descrevemos um caso encontrado em nosso serviço, com tal variação anatômica incomum.


Secondary middle turbinate is an anatomical variant rarely observed in the nasal cavity, firstly described by Khanobthamchai et al. as a bone structure originating from the lateral nasal wall and covered by soft tissue. In most cases reported in the literature, this variant is bilateral, occurring without associated complications. In the present report, the authors describe the case of patient of their institution with such anatomical variation.


Asunto(s)
Humanos , Femenino , Persona de Mediana Edad , Cornetes Nasales/anatomía & histología , Cornetes Nasales/anomalías , Cavidad Nasal , Obstrucción Nasal , Cefalea , Tomografía Computarizada por Rayos X
13.
Rev. imagem ; 33(1/2): 7-14, jan.-jun. 2011. ilus
Artículo en Portugués | LILACS | ID: lil-644370

RESUMEN

As variantes anatômicas dos seios da face são achados comuns na prática diária. O conhecimento destas variações por parte dos radiologistas faz-se necessário tanto pelas condições patológicas relacionadas como também pela importância no planejamento da cirurgia endoscópica funcionalendonasal. A cirurgia endonasal é o procedimento de escolha para diagnóstico, biópsias e tratamentode várias doenças nasossinusais, e para que seja efetuada com segurança, prevenindo-se lesões iatrogênicas, é fundamental que o cirurgião tenha o mapeamento dessas estruturas. Dessaforma, a tomografia computadorizada torna-se indispensável para avaliação pré-operatória dos seios da face. Revisão da literatura e ensaio iconográfico foram realizados com o objetivo de discutir a importância das principais variantes anatômicas dos seios paranasais, pois o conhecimento dessas alterações e suas relações com condições patológicas é uma habilidade que se espera do radiologista geral.


Anatomic variations of paranasal sinuses are common findings in daily practice. For a radiologist, to know these variations is necessary because of the pathological conditions related to them, and also because they are import for planning a functional endoscopicendonasal surgery, the procedure of choice for diagnosis, biopsy and treatment of various sinonasal diseases. To assure that this surgery is done safely, preventing iatrogenic injuries, it is essential that the surgeon has the mapping of these structures. Thus, aCT is indispensable for preoperative evaluation of paranasal sinuses.Since a general radiologist is expected to know these changes and their relationship to pathological conditions, a literature review and a iconographic essay were conducted with the aimof discussing the importance of major anatomic variations of paranasal sinuses.


Asunto(s)
Endoscopía/métodos , Senos Paranasales/anatomía & histología , Tomografía Computarizada por Rayos X
14.
Rev. imagem ; 32(3/4): 39-44, jul.-dez. 2010. ilus
Artículo en Portugués | LILACS | ID: lil-613157

RESUMEN

O objetivo deste trabalho foi demonstrar os achados tomográficos normais e patológicos encontrados no pós-operatório de pacientes submetidos a implantes de prótese ossicular, avaliados retrospectivamente por tomografia computadorizada. A estapedectomia com inserção de prótese é considerada o método ideal em indivíduos com fechamento da janela oval secundário a otosclerosefenestral ou causas inflamatórias. Vários tipos de prótese são utilizados, dependendo da extensãoda doença e preferência do cirurgião. Os autores, após revisão da literatura, descrevem os achadospós-operatórios considerados normais e as várias complicações inerentes ao procedimentocirúrgico, incluindo perfuração da membrana timpânica, processo inflamatório pós-operatório, necrosecom subluxação ou extrusão da prótese, desenvolvimento de granuloma/colesteatoma oufibrose periprotética, fístula perilinfática, lesão do nervo facial, dentre outras. Os achados tomográficos relacionados ao pós-operatório, bem como às complicações supracitadas, são de grande importância para o conhecimento dos radiologistas, sendo imprescindível para a propedêutica diagnóstica uma estreita correlação clínico-cirúrgica.


The aim of this essay was to demonstrate the normal and pathological CT findings of the post-operative imaging of patients underwent ossicular prosthesis implants. The stapedectomy replacedby prosthesis is considered the “gold standard” treatment of patients with oval window closure, related to otosclerosis or otherinflammatory conditions. Several types of prosthesis are availableand the choice depends on the extension of the disease or thesurgeon’s preferences. Based on extensive literature review, thenormal postoperative findings, as well as some surgery inherentcomplications were described, including among others: perforationof the tympanic membrane, necrosis associated with subluxation/extrusion of the prosthesis. granuloma/cholesteatoma or periprosthetic fibrosis, perilymphatic fistula, facial nerve damage. The knowledge of post-operative and related complications CT findings is extremely useful for head and neck radiologist, but it is essentialfor an assertive diagnoses a close clinical correlation.


Asunto(s)
Humanos , Cirugía del Estribo/efectos adversos , Cirugía del Estribo/métodos , Prótesis Osicular , Oído Medio/cirugía , Tomografía Computarizada Espiral/métodos , Periodo Posoperatorio , Estudios Retrospectivos
15.
Rev. imagem ; 31(1/2): 7-12, jan.-jun. 2009. ilus
Artículo en Portugués | LILACS | ID: lil-542442

RESUMEN

Após a redução da fratura, dispositivos de fixação interna ou externa podem ser utilizados para promover estabilidade e manter o alinhamento dos fragmentos ósseos. O objetivo do presente estudoé descrever a aparência radiológica e a aplicação dos principais materiais cirúrgicos usados no tratamento de fraturas. Os autores fazem uma revisão bibliográfica sobre o tema e apresentamimagens radiográficas que ilustram o uso dos principais dispositivos de fixação de fratura. Na primeira parte deste estudo, serão abordados os princípios biomecânicos envolvidos no design e na aplicação dos principais tipos de fios e parafusos utilizados para osteossíntese, assim como a aparência radiológica destes e os termos ortopédicos utilizados para descrevê-los. Entendemos que o papel do radiologista na abordagem das fraturas compreende desde a sua detecção até acaracterização do tipo de tratamento e sua evolução, o que torna essencial a familiarização deste profissional com os materiais usados para a fixação de fraturas.


After the reduction of a fracture, internal or external devices of fixation can be used to promote stability and keep the alignment of the bone fragments during the healing process. The objective ofthe present study is to describe the radiologic findings and the applicationof surgery materials found in daily practice and used in fractures treatment. The authors perform a review on the subject and present radiographic images showing the use of the main fracturesfixation devices. In the first part of this study, the biological and biomechanical aspects related to the design and the application of different wires and screws used to the osteosynthesis willbe approached as well as the radiologic findings and orthopedic terms used to describe them. We understand that the work of the radiologist in the fracture approach includes from the diagnosisto the characterization of the lesion and its evolution. Therefore, it is important that the radiologist knows the applications of the fracture fixation devices.


Asunto(s)
Humanos , Tornillos Óseos , Hilos Ortopédicos , Fijación Interna de Fracturas/instrumentación , Fracturas Cerradas/cirugía , Fracturas Cerradas , Clavos Ortopédicos
16.
Rev. imagem ; 31(1/2): 13-18, jan.-jun. 2009. ilus
Artículo en Portugués | LILACS | ID: lil-542443

RESUMEN

Após a redução da fratura, dispositivos de fixação interna ou externa podem ser utilizados para promover estabilidade e manter o alinhamento dos fragmentos ósseos. O objetivo do presente estudoé descrever a aparência radiológica e a aplicação dos principais materiais cirúrgicos usados no tratamento de fraturas. Os autores fazem uma revisão bibliográfica sobre o tema e apresentamimagens radiográficas que ilustram o uso dos principais dispositivos de fixação de fratura. Na segunda parte deste estudo serão enfatizados os aspectos radiológicos dos principais tipos de placas, hastes intramedulares e fixadores externos, assim como a aplicação destes dispositivos no tratamento das fraturas. Entendemos que o papel do radiologista na abordagem das fraturas compreendedesde a sua detecção até a caracterização do tipo de tratamento e sua evolução, o que torna essencial a familiarização deste profissional com os materiais usados para a fixação de fraturas.


After the reduction of a fracture, internal or external fixation devices can be used to promote stability and keep the alignment of the bone fragments during the healing process. The objective ofthe present study is to describe the radiologic findings and the applicationof surgery materials found in daily practice and used in fractures treatment. The authors perform a review on the subject and present radiographic images showing the utilization of the mainfractures fixation devices. In the second part of this study the radiologic findings of the main plates, intramedullary nails and external fixation frames will be emphasized and its application willalso be approached. We understand that the work of the radiologist in the fracture approach includes from the diagnosis to the characterization of the lesion and its evolution. Therefore, it is important that the radiologist knows the applications of the fracture fixation devices.


Asunto(s)
Humanos , Fijación Intramedular de Fracturas/instrumentación , Fracturas Abiertas , Radiografía , Técnica de Ilizarov/instrumentación
17.
Rev. imagem ; 29(4): 127-131, out.-dez. 2007. ilus
Artículo en Portugués | LILACS | ID: lil-542267

RESUMEN

A deiscência do canal semicircular superior foi descrita por Minor e cols. em 1998 e tem como definição a ausência de cobertura óssea sobre o canal semicircular superior na zona próxima à duramáter na fossa craniana média, o que seria equivalente a uma terceira janela. Sabe-se que qualquer processo que crie uma comunicação adicional com o labirinto leva a sinais e sintomas clínicos semelhantes, sendo, portanto, denominado terceira janela. Os objetivos deste trabalho são apresentar o conceito de terceira janela, destacar a fisiopatologia, a clínica e os diagnósticos diferenciais, e discutir os achados de imagem, inclusive com casos de nosso serviço. As janelas redonda e oval são as duas aberturas fisiológicas do sistema hidráulico da orelha interna. Medianteuma terceira janela, este sistema é rompido e há alteração da fisiologia do labirinto, gerando sinais e sintomas auditivos e vestibulares. Terceira janela é um novo conceito no campo da otologia. O tratamento por parte do otorrinolaringologista depende da identificação desse distúrbio peloradiologista.


The superior semicircular canal dehiscence was described first time by Minor in 1998 and the definition is the absence of bone cover on superior semicircular canal in the zone adjacent duramater, equivalent third window. Any process that does a labyrinth additional communication produces similar signs and symptoms, denominated third window. The objective of this study was to introduce the third window conception, emphasizing physiology,pathology, clinical issues and different diagnostic, discussing imaging findings, together with cases of owner service. The oval and round windows are physiologies openings hydraulic system of the inner ear. Through a third window, this system is breaking and has a labyrinth physiology disorder, producing vestibular signs and symptoms and hearing loss. Third window is a new conception. Adequate treatment by specialist doctor depends on correct identification by radiologist.


Asunto(s)
Humanos , Canales Semicirculares/anomalías , Espectroscopía de Resonancia Magnética , Ventana Redonda/fisiopatología , Ventana Oval/fisiopatología , Oído Interno/fisiopatología , Tomografía Computarizada por Rayos X , Diagnóstico Diferencial
18.
Radiol. bras ; Radiol. bras;34(2): 113-115, mar.-abr. 2001. ilus
Artículo en Portugués | LILACS | ID: lil-309847

RESUMEN

O hepatocarcinoma fibrolamelar é neoplasia hepatocelular rara, diagnosticada por tomografia computadorizada e confirmada pelo exame anatomopatológico. O caso relatado foi atendido no Hospital Mater Dei de Belo Horizonte, MG. Os aspectos clínicos, radiológicos e patológicos discutidos reforçam a importância das imagens radiológicas na detecção e caracterização das neoplasias focais hepáticas.


Asunto(s)
Humanos , Masculino , Niño , Neoplasias Hepáticas/diagnóstico , Carcinoma Hepatocelular , Hepatomegalia
19.
Radiol. bras ; Radiol. bras;33(4): 211-4, jul-.ago. 2000. ilus, tab
Artículo en Portugués | LILACS | ID: lil-277578

RESUMEN

Avaliamos 90 exames do abdome, por tomografia computadorizada helicoidal, de pacientes que ingeriram soluçäo de iodo diluído a 1 por cento, leite integral ou nenhum meio de contraste oral antes do procedimento. Os resultados dos pacientes que ingeriram o leite integral foram superiores aos demais nos quatro parâmetros avaliados: distensäo gastroduodenal, visibilidade parietal, discriminaçäo pâncreas-duodeno e discriminaçäo entre alças intestinais. O leite integral é um eficiente meio de contraste oral de baixa densidade.


Asunto(s)
Humanos , Masculino , Femenino , Niño , Adolescente , Adulto , Persona de Mediana Edad , Abdomen , Medios de Contraste , Leche , Anciano de 80 o más Años , Diagnóstico por Imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA