Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Kidney Int ; 104(1): 189-200, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36990214

RESUMEN

Use of a covered stent after percutaneous transluminal angioplasty (PTA) was compared to PTA alone for treatment of upper extremity hemodialysis patients with arteriovenous fistula (AVF) stenoses. Patients with AVF stenosis of 50% or more and evidence of AVF dysfunction underwent treatment with PTA followed by randomization of 142 patients to include a covered stent or 138 patients with PTA alone. Primary outcomes were 30-day safety, powered for noninferiority, and six-month target lesion primary patency (TLPP), powered to test whether TLPP after covered-stent placement was superior to PTA alone. Twelve-month TLPP and six-month access circuit primary patency (ACPP) were also hypothesis tested while additional clinical outcomes were observed through two years. Safety was significantly non-inferior while six- and 12-month TLPP were each superior for the covered stent group compared to PTA alone (six months: 78.7% versus 55.8%; 12 months: 47.9% versus 21.2%, respectively). ACPP was not statistically different between groups at six-months. Observed differences at 24 months favored the covered-stent group: 28.4% better TLPP, fewer target-lesion reinterventions (1.6 ± 1.6 versus 2.8 ± 2.0), and a longer mean time between target-lesion reinterventions (380.4 ± 249.5 versus 217.6 ± 158.4 days). Thus, our multicenter, prospective, randomized study of a covered stent used to treat AVF stenosis demonstrated noninferior safety with better TLPP and fewer target-lesion reinterventions than PTA alone through 24 months.


Asunto(s)
Angioplastia de Balón , Fístula Arteriovenosa , Derivación Arteriovenosa Quirúrgica , Humanos , Oclusión de Injerto Vascular/diagnóstico por imagen , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/terapia , Grado de Desobstrucción Vascular , Constricción Patológica/etiología , Angioplastia de Balón/efectos adversos , Estudios Prospectivos , Resultado del Tratamiento , Derivación Arteriovenosa Quirúrgica/efectos adversos , Angioplastia/efectos adversos , Stents , Fístula Arteriovenosa/etiología , Diálisis Renal/efectos adversos
2.
J Vasc Interv Radiol ; 33(5): 479-488.e3, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35181497

RESUMEN

PURPOSE: To study the use of the self-expanding Covera covered stent for the treatment of stenotic lesions at the venous anastomosis of hemodialysis arteriovenous grafts (AVGs). MATERIALS AND METHODS: A total of 110 patients with AVG venous anastomotic stenosis of ≥50% and access dysfunction were treated at 14 centers in the United States using percutaneous transluminal angioplasty followed by covered stent placement. The primary end points were 30-day safety and 6-month target lesion primary patency (TLPP). The secondary measures included access circuit primary patency, circuit cumulative patency, and the number of reinterventions through 24 months. RESULTS: Freedom from a primary safety event at 30 days was 96.4% while the 6-month TLPP rate was 70.3%. Seventy-five patients completed 24-month follow-up (68.2%). The TLPP rates were 54.2% at 365 days and 36.9% at 730 days while the access circuit primary patency rates were 16.7% at 365 days and 7.8% at 730 days (Kaplan-Meier analysis). The access circuit cumulative patency rates were 85.4% at 12 months and 73.6% at 24 months. The number of reinterventions to maintain the patency of the access circuit was 3.6 ± 3.1 at 24 months (1.6 ± 1.9 at the target lesion). CONCLUSIONS: Use of the Covera covered stent for hemodialysis graft-vein anastomotic stenosis provided a safe treatment option with a TLPP rate of 70.3% at 6 months and TLPP and cumulative access circuit patency rates of 36.9% and 73.6% at 2 years.


Asunto(s)
Angioplastia de Balón , Derivación Arteriovenosa Quirúrgica , Enfermedades Vasculares , Anastomosis Quirúrgica , Angioplastia de Balón/efectos adversos , Derivación Arteriovenosa Quirúrgica/efectos adversos , Constricción Patológica , Oclusión de Injerto Vascular/diagnóstico por imagen , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/terapia , Humanos , Estudios Prospectivos , Diálisis Renal , Stents , Resultado del Tratamiento , Estados Unidos , Grado de Desobstrucción Vascular
3.
J Vasc Interv Radiol ; 31(3): 494-502, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31959517

RESUMEN

PURPOSE: To evaluate the patency, cellular response, and thrombogenicity of a novel vascular stent graft. MATERIALS AND METHODS: Test stent grafts, incorporating luminal spun polytetrafluoroethylene and a nonpermeable fluoropolymer layer, and control stent grafts, constructed of permeable expanded polytetrafluoroethylene, were implanted in the external iliac arteries of 14 adult sheep with a median weight of 73.4 kg ranging from 60.6-86.8 kg for 30 (n = 4), 90 (n = 4), and 180 (n = 6) days. Angiographic patency and percent diameter stenosis (%DS) were assessed at termination. Excised stent grafts were fixed and stained for histopathologic analysis, including neointimal coverage (NC) assessment. RESULTS: Test and control device migration occurred in 1 animal, resulting in test device thrombosis. Both devices were excluded from analysis. Mean %DS in test and control implants was 4.6% and 8.2% (P = .563), 2.0% and 10.9% (P = .363), and 2.1% and 10.3% (P = .009) at 30, 90, and 180 days, respectively. Median NC scores at 30, 90, and 180 days were significantly lower in middle test device sections (P < .05). Proximal and distal test and control sections exhibited similar median NC scores at all time periods (P > .05). When present, test and control devices exhibited no neointimal detachment from the graft surface. Except for the migrated test device, no thrombus was observed. Transgraft cellular migration was absent in test devices but present in control devices with tissue accumulation around the stent struts. CONCLUSIONS: Test and control devices demonstrated excellent patency in an ovine model. Compared to the control, test devices exhibited significantly lower %DS values at 180 days and significantly lower mid-device NC scores at 30, 90, and 180 days.


Asunto(s)
Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Arteria Ilíaca/cirugía , Politetrafluoroetileno/química , Stents , Animales , Implantación de Prótesis Vascular/efectos adversos , Femenino , Migración de Cuerpo Extraño/etiología , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/patología , Oclusión de Injerto Vascular/fisiopatología , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/patología , Arteria Ilíaca/fisiopatología , Masculino , Ensayo de Materiales , Modelos Animales , Neointima , Diseño de Prótesis , Oveja Doméstica , Trombosis/etiología , Trombosis/patología , Trombosis/fisiopatología , Factores de Tiempo , Grado de Desobstrucción Vascular
5.
J Vasc Interv Radiol ; 29(6): 765-773.e2, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29706343

RESUMEN

PURPOSE: To conduct an economic analysis on the impact of increased stent graft (SG) use for treatment of arteriovenous graft (AVG) anastomotic stenosis or arteriovenous fistula (AVF)/AVG in-stent restenosis (ISR) from United States point-of-care (POC) and Medicare perspectives. MATERIALS AND METHODS: The analyses compared initial device and reintervention costs over 2 years between current and projected treatment mixes, including percutaneous transluminal angioplasty (PTA), bare metal stents (BMSs), and SGs. In projected scenarios, the absolute increase in SG use was approximately 3%. Costs included procedure reimbursement rates (Medicare) and device list prices (POC) for index procedures and reinterventions. Reintervention rates and types were informed by the RENOVA and RESCUE randomized trials. Reinterventions were primarily PTA only; however, stent use occurred a proportion of the time. BMS reintervention rates were assumed to be identical to PTA based on observational data. A population size of 1,000 patients was assumed. RESULTS: To the POC (n = 1,000), increased SG use was predicted to result in cost savings ranging from $4,106 to $34,420 for AVG anastomotic stenosis. For AVF/AVG ISR, increased SG use was predicted to result in either a cost increase of $17,187 or a cost savings of $13,159. To Medicare (n = 1,000), increased SG use was predicted to save costs for both populations, with savings ranging from $57,401 to $169,544. CONCLUSIONS: The use of SG for treatment of AVG anastomotic stenosis and AVF/AVG ISR appears to be economically favorable for POC providers and Medicare. Further data on reintervention rates are required from other SG trials to validate findings.


Asunto(s)
Prótesis Vascular/economía , Oclusión de Injerto Vascular/economía , Oclusión de Injerto Vascular/terapia , Sistemas de Atención de Punto/economía , Stents/economía , Angioplastia/economía , Constricción Patológica , Costos y Análisis de Costo , Humanos , Medicare/economía , Retratamiento/economía , Estados Unidos , Grado de Desobstrucción Vascular
6.
J Vasc Interv Radiol ; 33(10): 1151-1152, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36182252
7.
N Engl J Med ; 362(6): 494-503, 2010 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-20147715

RESUMEN

BACKGROUND: The leading cause of failure of a prosthetic arteriovenous hemodialysis-access graft is venous anastomotic stenosis. Balloon angioplasty, the first-line therapy, has a tendency to lead to subsequent recoil and restenosis; however, no other therapies have yet proved to be more effective. This study was designed to compare conventional balloon angioplasty with an expanded polytetrafluoroethylene endovascular stent graft for revision of venous anastomotic stenosis in failing hemodialysis grafts. METHODS: We conducted a prospective, multicenter trial, randomly assigning 190 patients who were undergoing hemodialysis and who had a venous anastomotic stenosis to undergo either balloon angioplasty alone or balloon angioplasty plus placement of the stent graft. Primary end points included patency of the treatment area and patency of the entire vascular access circuit. RESULTS: At 6 months, the incidence of patency of the treatment area was significantly greater in the stent-graft group than in the balloon-angioplasty group (51% vs. 23%, P<0.001), as was the incidence of patency of the access circuit (38% vs. 20%, P=0.008). In addition, the incidence of freedom from subsequent interventions at 6 months was significantly greater in the stent-graft group than in the balloon-angioplasty group (32% vs. 16%, P=0.03 by the log-rank test and P=0.04 by the Wilcoxon rank-sum test). The incidence of binary restenosis at 6 months was greater in the balloon-angioplasty group than in the stent-graft group (78% vs. 28%, P<0.001). The incidences of adverse events at 6 months were equivalent in the two treatment groups, with the exception of restenosis, which occurred more frequently in the balloon-angioplasty group (P<0.001). CONCLUSIONS: In this study, percutaneous revision of venous anastomotic stenosis in patients with a prosthetic hemodialysis graft was improved with the use of a stent graft, which appears to provide longer-term and superior patency and freedom from repeat interventions than standard balloon angioplasty. (ClinicalTrials.gov number, NCT00678249.)


Asunto(s)
Angioplastia de Balón , Derivación Arteriovenosa Quirúrgica , Oclusión de Injerto Vascular/terapia , Diálisis Renal , Stents , Angioplastia de Balón/efectos adversos , Derivación Arteriovenosa Quirúrgica/métodos , Catéteres de Permanencia/efectos adversos , Femenino , Estudios de Seguimiento , Oclusión de Injerto Vascular/etiología , Humanos , Análisis de Intención de Tratar , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Recurrencia , Stents/efectos adversos , Insuficiencia del Tratamiento , Grado de Desobstrucción Vascular
9.
Dig Dis Sci ; 58(7): 2100-6, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23381105

RESUMEN

BACKGROUND: Transjugular intrahepatic portosystemic shunts (TIPS) created with expanded poly-tetrafluoroethylene-covered stents have largely replaced bare metal stents. Short-term shunt patency is typically assessed with protocol Doppler ultrasound (US), while little information exists with regard to long-term patency. AIM: We investigated the value of Doppler US in assessing TIPS patency as well as long-term clinical outcomes. METHODS: A retrospective analysis of 59 patients with covered stents used for TIPS between January 2001 and December 2011 was performed. RESULTS: Fifty-four patients had early (median 9 days) Doppler US follow-up. Seven of eight patients with an abnormal baseline US required stent revisions. None of the 46 patients with normal baseline Doppler US required revisions within the first 6 months; six of these patients subsequently had a portogram because of symptoms, but all TIPS were patent. Fifty-two patients survived for long-term (>6 months) follow-up, averaging 654 days and three Doppler US exams. Five of six patients with abnormal follow-up Doppler US required revisions, whereas none of the 46 patients with normal follow-up US had revisions. The recurrence of symptoms of portal hypertension and/or hepatic encephalopathy (HE) was low (4/52 patients). No significant predictors of long-term stenosis were identified. Post-TIPS HE was independent of pre-TIPS HE or Child-Pugh score. CONCLUSIONS: Short-term patency and that at approximately 2 years after TIPS placement was 87 and 77 %, respectively. We conclude that Doppler US at least 1 week after TIPS is warranted, but repeated Doppler US follow-up is probably not necessary in the absence of clinical symptoms.


Asunto(s)
Falla de Equipo/estadística & datos numéricos , Hipertensión Portal/cirugía , Politetrafluoroetileno , Derivación Portosistémica Intrahepática Transyugular/instrumentación , Stents , Ultrasonografía Doppler , Adulto , Femenino , Estudios de Seguimiento , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Reoperación/estadística & datos numéricos , Estudios Retrospectivos , Resultado del Tratamiento
10.
J Vasc Interv Radiol ; 23(4): 479-87, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22464712

RESUMEN

PURPOSE: To review technical and 180-day clinical outcomes when stent grafts were used to treat dysfunctional arteriovenous (AV) hemodialysis access circuits. MATERIALS AND METHODS: The FLUENCY Plus Stent Graft (Bard Peripheral Vascular, Tempe, Arizona) was used to salvage percutaneous transluminal angioplasty (PTA) technical failures and complications in AV access circuits over 2 years. There were 106 patients treated with 138 stent grafts. Indications for stent graft use included residual stenosis after PTA (n = 81), extravasation after PTA (n = 22), early recurrent stenosis (n = 14), pseudoaneurysms (n = 4), and "other" (n = 4). Data were retrospectively analyzed for complications and outcomes. RESULTS: Technical success was achieved in all patients, and clinical success was achieved in 104 (98%) of 106 patients. At 180 days, postintervention primary patency (PIPP) was 47%, and postintervention secondary patency (PISP) was 79%. PIPP was 62% for autogenous fistulas (AVFs) and 35% for prosthetic grafts (AVGs) (P = .010). The 180-day PIPP for stent grafts 9-10 mm in diameter was 63% versus 38% for stent grafts 6-8 mm in diameter (P = .012). Implants that did not cross the elbow had a 180-day PIPP of 47% compared with 25% for implants across the elbow (P = .032). Technical complications were periprocedure AVG thromboses (n = 2), intraprocedural stent graft dislodgment (n = 1), venospasm (n = 2), and contrast agent-related hives (n = 1). One patient returned at 2 months with an infected AVG and stent graft in the outflow vein. CONCLUSIONS: The FLUENCY Plus Stent Graft was effective for maintenance of hemodialysis access circuit patency and was comparable or better than historical outcomes for PTA and bare stents. Factors that favored improved patency included larger diameter devices, use in AVFs, and avoiding placement across the elbow joint.


Asunto(s)
Angioplastia/estadística & datos numéricos , Prótesis Vascular/estadística & datos numéricos , Catéteres de Permanencia/estadística & datos numéricos , Rechazo de Injerto/epidemiología , Complicaciones Posoperatorias/epidemiología , Diálisis Renal/estadística & datos numéricos , Stents/estadística & datos numéricos , Anciano , Anciano de 80 o más Años , Análisis de Falla de Equipo , Femenino , Supervivencia de Injerto , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Prevalencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Terapia Recuperativa , Resultado del Tratamiento , Estados Unidos/epidemiología
11.
J Vasc Interv Radiol ; 22(11): 1570-4, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21937239

RESUMEN

PURPOSE: To report experience with endovascular treatment of traumatic injuries of the main renal artery. MATERIALS AND METHODS: A retrospective review of traumatic injuries to the main renal artery was performed in three major trauma institutions. Eight patients (age range, 17-46 y; mean age, 27 y) presented with main renal artery occlusion (n = 7) or dissection (n = 1) after major blunt abdominal trauma. Associated injuries were present in the majority of patients. The mean time from injury to intervention was 5 hours (range, 2-8 h). RESULTS: Recanalization of the occluded renal artery with stent placement was successfully achieved in six patients. In two of the eight patients, interventions resulted in extravasation of contrast medium, and embolization of the main renal artery was performed. At follow-up 2-24 months after injury, four patients had kidney atrophy (two treated with embolization and two with stents), two had proven stent patency with functional kidneys, one was normotensive with unknown stent patency, and one was lost to follow-up. One of the patients with an occluded stent developed severe renal hypertension and required nephrectomy. CONCLUSIONS: The majority of occlusions and dissections of the main renal artery after major blunt abdominal trauma can be successfully treated with recanalization and stent placement. However, long-term kidney salvage is not always achieved, and there is a potential of development of renovascular hypertension, which may require late nephrectomy.


Asunto(s)
Traumatismos Abdominales/terapia , Disección Aórtica/terapia , Procedimientos Endovasculares/instrumentación , Obstrucción de la Arteria Renal/terapia , Heridas no Penetrantes/terapia , Traumatismos Abdominales/etiología , Accidentes de Tránsito , Adolescente , Adulto , Disección Aórtica/etiología , Embolización Terapéutica , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Hipertensión Renovascular/etiología , Hipertensión Renovascular/cirugía , Louisiana , Masculino , Persona de Mediana Edad , Traumatismo Múltiple , Nefrectomía , Obstrucción de la Arteria Renal/etiología , Estudios Retrospectivos , Stents , Texas , Factores de Tiempo , Centros Traumatológicos , Resultado del Tratamiento , Heridas no Penetrantes/etiología , Adulto Joven
12.
J Vasc Interv Radiol ; 21(3): 322-6, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20097095

RESUMEN

PURPOSE: To review technical and patency results with expanded polytetrafluoroethylene (ePTFE)-covered stents for treatment of venous rupture encountered during percutaneous hemodialysis intervention. MATERIALS AND METHODS: The Fluency covered stent is a tracheobronchial device that was used in an off-label manner to treat percutaneous transluminal angioplasty (PTA)-induced rupture in hemodialysis circuits. Data were retrospectively reviewed for all patients treated with the stent in 2004-2005 at two medical centers for PTA-related rupture. RESULTS: From a database of 106 procedures, 21 patients (21 procedures) were treated with the ePTFE-covered stent for PTA-related extravasation. Nine patients had arteriovenous (AV) grafts and 12 had AV fistulas. Five extravasations followed angioplasty as part of an AV graft declotting procedure. Location of extravasation was the outflow or cannulation venous segment (n = 11), cephalic arch (n = 3), AV graft venous anastomosis (n = 6), and intragraft (n = 1). All procedures were technically successful at halting extravasation and preserving vascular access. There were no known complications, and all patients underwent a successful first dialysis session. Twenty of the 21 circuits remained patent beyond the first week after intervention. The 180-day primary circuit patency rate was 20% and the 180-day cumulative circuit patency rate was 65%. CONCLUSIONS: In 21 patients, the ePTFE-covered stent successfully treated PTA-induced rupture with no need for acute secondary procedures such as thrombolysis or surgery. There was no instance of pseudoaneurysm formation or delayed bleeding. The ePTFE-covered stent offers advantages compared to prolonged PTA or bare stents when attempting to preserve hemodialysis access after PTA-induced rupture.


Asunto(s)
Angioplastia/efectos adversos , Prótesis Vascular , Extravasación de Materiales Terapéuticos y Diagnósticos/etiología , Extravasación de Materiales Terapéuticos y Diagnósticos/terapia , Diálisis Renal/efectos adversos , Stents , Anciano , Derivación Arteriovenosa Quirúrgica/efectos adversos , Materiales Biocompatibles Revestidos/química , Femenino , Polímeros de Fluorocarbono/química , Humanos , Masculino , Persona de Mediana Edad , Grado de Desobstrucción Vascular
13.
J Vasc Interv Radiol ; 21(8): 1173-84, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20598570

RESUMEN

PURPOSE: To evaluate the safety and effectiveness of the retrievable Option inferior vena cava (IVC) filter in patients at risk for pulmonary embolism (PE). MATERIALS AND METHODS: This was a prospective, multicenter, single-arm clinical trial. Subjects (N = 100) underwent implantation of the IVC filter and were followed for 180 days; subjects whose filters were later removed were followed for 30 days thereafter. The primary objective was to determine whether the one-sided lower limit of the 95% CI for the observed clinical success rate was at least 80%. Clinical success was defined as technical success (deployment of the filter such that it was judged suitable for mechanical protection from PE) without subsequent PE, significant filter migration or embolization, symptomatic caval thrombosis, or other complications. RESULTS: Technical success was achieved in 100% of subjects. There were eight cases of recurrent PE, two cases of filter migration (23 mm), and three cases of symptomatic caval occlusion/thrombosis (one in a subject who also experienced filter migration). No filter embolization or fracture occurred. Clinical success was achieved in 88% of subjects; the one-sided lower limit of the 95% CI was 81%. Retrieval was successful at a mean of 67.1 days after implantation (range, 1-175 d) for 36 of 39 subjects (92.3%). All deaths (n = 17) and deep vein thromboses (n = 18) were judged to have resulted from preexisting or intercurrent illnesses or interventions and unrelated to the filter device; all deaths were judged to be unrelated to PE. CONCLUSIONS: Placement and retrieval of the Option IVC filter were performed safely and with high rates of clinical success.


Asunto(s)
Embolia Pulmonar/prevención & control , Tromboembolia/terapia , Filtros de Vena Cava , Trombosis de la Vena/terapia , Adulto , Anciano , Remoción de Dispositivos , Femenino , Migración de Cuerpo Extraño/etiología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Embolia Pulmonar/etiología , Recurrencia , Tromboembolia/complicaciones , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos , Filtros de Vena Cava/efectos adversos , Trombosis de la Vena/complicaciones
14.
J Vasc Access ; 21(5): 543-553, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31884872

RESUMEN

Although not common, hemodialysis access-induced distal ischemia is a serious condition resulting in significant hemodialysis patient morbidity. Patients with signs and symptoms suggestive of hand ischemia frequently present to the general and interventional nephrologist for evaluation. In order to care for these cases, it is necessary to understand this syndrome and its management. Most cases can be managed conservatively without intervention. Some cases requiring intervention may be treated using techniques within the scope of practice of the interventional nephrologists while other cases require vascular surgery. In order for the interventional nephrologists to evaluate and manage these cases in a timely and appropriate manner, practice guidelines are presented.


Asunto(s)
Derivación Arteriovenosa Quirúrgica/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Mano/irrigación sanguínea , Isquemia/terapia , Nefrólogos/normas , Pautas de la Práctica en Medicina/normas , Radiografía Intervencional/normas , Radiólogos/normas , Diálisis Renal/normas , Circulación Colateral , Consenso , Humanos , Isquemia/diagnóstico por imagen , Isquemia/etiología , Isquemia/fisiopatología , Radiografía Intervencional/efectos adversos , Flujo Sanguíneo Regional , Factores de Riesgo , Resultado del Tratamiento
15.
Ann Surg ; 249(2): 318-21, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19212188

RESUMEN

OBJECTIVE: We hypothesized that an adrenal vein sampling (AVS) algorithm incorporating rapid cortisol assays, which enables resampling of the adrenal veins, would improve the success rate by a team of radiologists. SUMMARY BACKGROUND DATA: AVS is the most accurate means to localize aldosterone production in primary aldosteronism (PA). However, cannulation of the right adrenal vein (RAV) is difficult, and success is assumed from venography without the support of steroid assays. Furthermore, few institutions can assign all studies to 1 dedicated and experienced AVS interventional radiologist. METHODS: Retrospective chart review of patients with PA at our university hospitals who underwent AVS. We compared results for 30 AVS studies incorporating rapid cortisol assays with 30 conventional AVS studies. RESULTS: The success rate for the control period was 73% (22/30 studies). For the first 30 studies after incorporating rapid cortisol assay, the success rate increased to 97% (29/30 studies). Resampling the RAV was required for 2 studies, and prolonged sheath insertion did not cause any complications. CONCLUSIONS: High AVS success rates may be achieved by a team of interventional radiologists at 1 center using defined AVS protocols. Rapid cortisol assay allows for resampling of the RAV and improves AVS success rates.


Asunto(s)
Glándulas Suprarrenales/irrigación sanguínea , Hidrocortisona/sangre , Hiperaldosteronismo/sangre , Hiperaldosteronismo/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Femenino , Humanos , Hiperaldosteronismo/cirugía , Inmunoensayo , Masculino , Persona de Mediana Edad , Flebografía , Estudios Retrospectivos , Factores de Tiempo , Venas
17.
J Vasc Interv Radiol ; 20(3): 407-9, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19157903

RESUMEN

The use of covered stents in treating delayed postoperative hepatic artery hemorrhage after pancreaticoduodenectomy may preserve hepatic arterial flow. The authors report two cases of massive hemorrhage after pancreaticoduodenectomy that were successfully treated with covered stents. Computed tomographic angiography demonstrated postprocedure patency of the hepatic arteries at 13 and 15 months, respectively. When technically feasible, percutaneous placement of stent-grafts may be used as a first-line intervention in delayed hemorrhage after pancreaticoduodenectomy.


Asunto(s)
Prótesis Vascular , Hemorragia/etiología , Hemorragia/cirugía , Arteria Hepática/lesiones , Arteria Hepática/cirugía , Pancreaticoduodenectomía/efectos adversos , Stents , Femenino , Hemorragia/diagnóstico por imagen , Arteria Hepática/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Radiografía , Resultado del Tratamiento
18.
AJR Am J Roentgenol ; 191(2): 569-77, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18647934

RESUMEN

OBJECTIVE: In this article, we discuss the neoaortoiliac system procedure, a surgical procedure that uses femoropopliteal vein segments for arterial reconstructions in patients with aortofemoral prosthetic graft infections. CONCLUSION: CT angiography (CTA) is a powerful imaging tool that can be used in the follow-up of patients after this complex surgery. CTA accurately detects early and late complications that may develop after the neoaortoiliac system procedure.


Asunto(s)
Angiografía/métodos , Aorta Abdominal/cirugía , Enfermedades de la Aorta/cirugía , Prótesis Vascular , Vena Femoral/trasplante , Vena Ilíaca/cirugía , Pierna/irrigación sanguínea , Vena Poplítea/trasplante , Complicaciones Posoperatorias/diagnóstico por imagen , Infecciones Relacionadas con Prótesis/cirugía , Tomografía Computarizada por Rayos X , Anastomosis Quirúrgica , Enfermedades de la Aorta/diagnóstico por imagen , Medios de Contraste , Humanos , Ultrasonografía Doppler Dúplex , Procedimientos Quirúrgicos Vasculares
19.
Radiographics ; 28(2): 529-48; discussion 549, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18349456

RESUMEN

Infrainguinal arterial bypass (IGAB) surgery is commonly performed in patients with claudication, critical limb ischemia, or other arterial problems in the lower extremities. An IGAB is constructed from different materials depending on the anatomy of the lesion and the availability of an autogenous vein. The ideal material for IGAB is the greater saphenous vein, especially for distal below-knee bypass. In patients with no available autogenous vein, IGAB can be performed by using different prosthetic materials or biologic grafts. After the surgery, periodic surveillance is performed with duplex ultrasonography and clinical assessment of peripheral pulses and ankle-brachial indexes. If complications are detected, further work-up is performed with conventional arteriography, multidetector computed tomographic (CT) angiography, or magnetic resonance angiography. CT angiography has become a powerful tool for assessing the potential early and late complications of IGAB and for planning further therapy in a fast, reliable, and noninvasive manner.


Asunto(s)
Angiografía/métodos , Arteriopatías Oclusivas/cirugía , Implantación de Prótesis Vascular/métodos , Arteria Femoral/cirugía , Pierna/irrigación sanguínea , Enfermedades Vasculares Periféricas/cirugía , Arteria Poplítea/cirugía , Complicaciones Posoperatorias/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Arteriopatías Oclusivas/diagnóstico por imagen , Medios de Contraste , Humanos , Recuperación del Miembro , Enfermedades Vasculares Periféricas/diagnóstico por imagen , Vena Safena/trasplante
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA