Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Int Endod J ; 57(1): 87-99, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37947444

RESUMEN

AIM: To investigate the influence of pulse energy, tip geometry and tip position in simulated 3D-printed root canals with multiple side canals at different levels in all directions on the cleaning performance of laser-activated irrigation (LAI) compared to sonic activation (EDDY) and conventional needle irrigation (NI). METHODOLOGY: 3D-printed root canal models (25/.06, length 20 mm, curvature 60°, radius 5 mm) with side canals (diameter 0.2 mm) at 2, 5 and 8 mm from the apex were filled with coloured biofilm-mimicking hydrogel. LAI (Morita AdvErL Evo, Kyoto, Japan) was performed with six settings (n = 20; pulse-energy, pulses per second [PPS], tip position): LAI1 (50 mJ, 25 PPS, P400FL, canal entrance [CE]), LAI2 (same as LAI1, but insertion depth 9 mm before the apical endpoint [AE] [corresponding to 1 mm above the first lateral canals]), LAI3 (80 mJ, 25 PPS, P400FL, 9 mm before AE), LAI4 (same as LAI 3, but at CE) for 3 × 20 s each, LAI5 (50 mJ, 25 PPS, P400FL 2 × 20 s, CE & R200T (30 mJ, 25 PPS, 1 × 20 s, 9 mm before AE), LAI6 (30 mJ, 25 PPS, R200T, 9 mm before AE, 3 × 20 s). A continuous irrigation (3 mL/20 s) using distilled water accompanied the irrigation cycles. NI and EDDY (3 × 20 s each; 3 mL/20 s irrigation, insertion AE minus 1 mm, amplitude 4 mm) served as control groups. Biofilm-mimicking hydrogel removal (ImageJ, NIH) was assessed for the entire system, the central canal and the lateral canals using standardized photographs with a microscope (Expert DN, Müller-Optronic) and statistically analysed was performed using Kruskal-Wallis and Dunn tests (p = .05). Irrigant extrusion beyond the foramina was also recorded. RESULTS: LAI2 (99.08%; interquartile range [IQR]: 96.85-100.00) and LAI3 (97.50%; 96.24-100.00) achieved the significantly best and LAI6 (80.08%; 73.41-84.69) the significantly worst removal of hydrogel from the entire root canal system amongst all LAI configurations (p < .05). There were no significant differences between LAI6, EDDY (72.89%; 67.49-76.22) and manual irrigation (54.39%; 51.01-56.94) (p > .05). R200T laser tip caused significantly more often irrigant extrusion than all other techniques (p < .05). CONCLUSION: Tip design, energy settings, and the positioning of the laser tip below the canal entrance caused an improvement in cleaning performance of the LAI. However, the small R200T tip created significantly more procedural errors (irrigant extrusion) due to higher concentrated energy.


Asunto(s)
Cavidad Pulpar , Láseres de Estado Sólido , Preparación del Conducto Radicular/métodos , Láseres de Estado Sólido/uso terapéutico , Irrigantes del Conducto Radicular , Hidrogeles , Irrigación Terapéutica/métodos
2.
Int Endod J ; 56 Suppl 3: 296-325, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35536159

RESUMEN

BACKGROUND: The diagnosis of the status of the inflamed pulp is essential in clinical diagnosis and treatment provision. There are a limited number of well-designed and well-executed clinical trials on the diagnosis of the true status of the pulp. OBJECTIVES: Three PICO questions were formulated and agreed a priori by the European Society of Endodontology to evaluate the clinical tests for sensibility testing, determination of biomarkers and pulp bleeding with regard to their suitability to correctly diagnose the condition of the pulp tissue for the development of S3-Level guidelines. METHODS: A literature search was conducted using PubMed, Clarivate Analytics' Web of Science, Scopus, Google Scholar and Cochrane Central Register of Controlled Trials from inception to 21 January 2022. Additionally, a hand search was performed, and the contents of the major subject journals were also examined. Eligibility criteria followed the proposed PICO questions. Two independent reviewers were involved in study selection, data extraction and appraising the included studies; disagreements were resolved by a third reviewer. The risk of bias was assessed by the QUADAS-2 tool for diagnostic accuracy studies, the Newcastle-Ottawa scale for noncomparative, nonrandomized studies and the Newcastle-Ottawa Quality Assessment scale adapted for cross-sectional studies. RESULTS: In total, 28 studies out of 29 publications were considered eligible and were included in the review. Twelve studies were identified to investigate the diagnostic accuracy of the pulp vitality. Ten studies fulfilled the criteria to evaluate the diagnostic accuracy of the pulpal conditions, while 6 studies investigating the expression of biomarkers were eligible. Three studies addressing the prognostic factors and therapeutic interventions relating to pulpal status were included. DISCUSSION: The core problem in pulp diagnostics is that a reliable reference standard is lacking under clinical conditions. Based on limited evidence, the most promising current approach seems to define a combination of different clinical tests and symptoms, probably in future including molecular diagnosis ("diagnostic package") will be required to ascertain the best possible strategy to clinically diagnose true pulpal conditions. CONCLUSIONS: The effectiveness of diagnosing pulpitis is low due to limited scientific evidence regarding the accuracy and reproducibility of diagnostic tests. There is a lack of evidence to determine the true status of the pulp or to identify prognostic indicators allowing for a reliable pre-operative estimation of the outcome of vital pulp treatment. REGISTRATION: PROSPERO database (CRD42021265366).


Asunto(s)
Enfermedades de la Pulpa Dental , Pulpitis , Humanos , Pulpitis/diagnóstico , Estudios Transversales , Reproducibilidad de los Resultados , Pulpa Dental , Biomarcadores
3.
Int Endod J ; 55 Suppl 1: 72-94, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34862796

RESUMEN

The aim of this review is to provide a critical overview of the physical properties (surface hardness, cutting efficiency, bending properties, flexibility and cyclic fatigue resistance) of NiTi instruments. Frequently used experimental models regarding these aspects will be presented and discussed with regard to their strengths and weaknesses. For all these aspects, a plethora of experimental models have been described. Based on a critical appraisal and especially taking the appropriate translation of experimental findings to clinical endodontics into account, suggestions for future research based on clearly defined and valid experimental methodologies will be provided. Up to now, very few attempts have been made to assess which particular physical properties of NiTi instruments exert an impact on the clinical outcome of root canal treatment. Departure from merely focusing on physical properties and fracture characteristics towards more biological aspects in terms of treatment outcome is essential.


Asunto(s)
Aleaciones Dentales , Endodoncia , Diseño de Equipo , Ensayo de Materiales , Modelos Teóricos , Preparación del Conducto Radicular , Estrés Mecánico , Propiedades de Superficie , Titanio
4.
Clin Oral Investig ; 24(3): 1217-1227, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31312970

RESUMEN

OBJECTIVES: The aim of this study was to determine the frequency and quality of root canal fillings (RCF) and the prevalence of apical radiolucency (AR) in a German population. MATERIAL AND METHODS: Five hundred randomly selected full-size CBCT images (Planmeca ProMax 3D, FOV = 8 × 8 cm, voxel size 160 µm or 200 µm) were obtained from German patients (40.6% = ♂; 59.4% = ♀; mean age = 50.21 ± 12.45 years). A total of 8254 teeth were examined for pathology (AR, widened periodontal ligament). The relationship between AR and existing RCF and the quality of RCF were documented. Frequency and correlations between the left and right sides and gender distribution were analyzed statistically using the chi-square test. RESULTS: The overall prevalence of AR was 3.8%, whereas for teeth with RCF, it was 42.5%. Patients had approximately 1.4 root canal-filled teeth (8.2% of all teeth). RCF terminated more than 2 mm short of the radiological apex in 31.2%, 5.1% reached beyond the apex, 8.1% were associated with extruded sealer, and 5.3% presented untreated root canals. Odds ratio of having an AR was highest in teeth with RCF beyond the apex (OR = 27.0) followed by RCF <2 mm short of the apex (OR = 4.4), untreated root canals (OR = 2.9), and inhomogeneity of RCF (OR = 1.2). Extrusion of sealer was least associated with AR. Molars were most frequently associated with AR (P < 0.05). Root canal-filled teeth showed significantly more AR in men compared with women (P < 0.05). CONCLUSIONS: About 42.5% of root canal-filled teeth were associated with AR, and in about one-third of these teeth, the RCF terminated more than 2 mm short of the apex. CLINICAL RELEVANCE: Each step in root canal therapy influences treatment outcome and prevalence of periapical radiolucencies. Determination of the working length is still one of the key points to achieve predictable periapical healing, and homogenous root canal filling reaching the foramen major seems to be essential.


Asunto(s)
Materiales de Obturación del Conducto Radicular , Obturación del Conducto Radicular , Tomografía Computarizada de Haz Cónico Espiral , Adulto , Cavidad Pulpar , Femenino , Alemania , Humanos , Masculino , Persona de Mediana Edad , Prevalencia
5.
Odontology ; 108(2): 174-179, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31446499

RESUMEN

The aim was to compare the shaping ability of different rotary nickel-titanium instruments in simulated S-shaped canals. One hundred S-shaped canals in resin blocks were prepared to an apical size 25 using F6 SkyTaper (Komet), Silk Files .04, Silk Files .06, Prototypes .04, and Prototypes .06 (all Mani) (20 canals/group). Material removal was measured at 20 measuring points, beginning 1 mm from the endpoint of preparation. Incidence of canal aberrations, preparation time, and instrument failures were also recorded. Statistical analyses were performed using ANOVA, Student-Newman-Keuls and Chi-square test. Pooled data of all measuring points revealed that canals instrumented with Prototypes .04 were significantly better centered than those prepared with all other instruments, while Prototypes .06 and both Silk Files performed significantly better than F6 SkyTaper (p < 0.05). The preparation time differed significantly between all groups and Prototypes .04 allowed the fastest preparation (p < 0.05). There was no statistically significant association between type of instrument and incidence of aberrations (p > 0.05). The cross-sectional design had a marked impact on the shaping ability of the instruments, and less tapered instruments maintained the original canal curvature better than instruments having greater tapers.


Asunto(s)
Níquel , Titanio , Estudios Transversales , Aleaciones Dentales , Instrumentos Dentales , Cavidad Pulpar , Diseño de Equipo , Humanos , Preparación del Conducto Radicular
6.
Odontology ; 107(2): 231-236, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30276580

RESUMEN

The aim was to evaluate the influence of different irrigation solutions on the push-out bond strength (POBS) of three different sealers (AH Plus, BioRoot RCS, GuttaFlow2). Root canals of 180 single-rooted human teeth were instrumented with F360 up to size 45.04. All canals were irrigated with 5 ml NaOCl 3% and 5 ml EDTA 17%. The canals were finally irrigated with either 5 ml NaOCl 3%, CHX 2%, EDTA 17%, citric acid 20% or NaCl 0.9% (n = 36) with a contact time of 5 min and obturated using matching gutta-percha cones according to the single-cone technique in combination with one of the sealers (n = 12). After 8 weeks of incubation, the roots were embedded in resin. Two slices of 1 mm thickness were obtained representing the middle third of the root. Dislodgement resistance was measured and POBS was calculated. Specimens were examined under 4× magnification to determine the mode of bond failure. Statistical analysis was performed using two-way ANOVA and Student-Newman-Keuls test for POBS and Chi-square test for the mode of failure. POBS was significantly affected by the factor "sealer" (P < 0.001) and by the interaction "sealer/irrigation solution" (P < 0.01). AH Plus revealed significantly higher POBS than BioRoot RCS and GuttaFlow2 (P < 0.05). The POBS of GutttaFlow2 was not affected by the irrigation protocol (P > 0.05). The POBS of AH Plus was positively influenced by EDTA and NaOCl. EDTA had a negative effect on the POBS of BioRoot RCS. The POBS of GuttaFlow2 was not influenced by the irrigation solutions.


Asunto(s)
Recubrimiento Dental Adhesivo , Materiales de Obturación del Conducto Radicular , Calcio , Compuestos de Calcio , Análisis del Estrés Dental , Dentina , Resinas Epoxi , Humanos , Ensayo de Materiales , Irrigantes del Conducto Radicular , Silicatos , Siliconas
7.
Odontology ; 107(4): 421-436, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30554288

RESUMEN

Recently, sealers based on calcium silicates were developed as a new class of endodontic sealers. Inspired by the excellent sealing ability and biocompatibility of calcium silicate-based cements, these sealers establish a biological point of view on the obturation of root canals. No longer, the bacteria-tight seal against reinfection of the root canal is the only goal of root canal obturation. Antibacterial properties as well as bioactive inducement of periapical healing and hard tissue formation are added to the portfolio of sealers. Ready-to-use sealers consisting of only one component with a need for external water supply from, e.g., body fluid and two components sealers with internal water supply were introduced to the market. Both of these material types have the same setting reactions in common whereby a hydration reaction of the calcium silicate is followed by a precipitation reaction of calcium phosphate. Though the available sealers are all based on calcium silicates, they consist of different compositions. Due to this aspect, differences in their physical and chemical properties as well as in their in vitro characteristics were described. Studies addressing the clinical impact of calcium silicate-based sealers on outcome are still sparse. The bioactive potential of sealers based on calcium silicates is a consequence of the slight solubility of these materials even after setting, but solubility of the sealer might also compromise the quality of sealing a root canal against regrowth and reinfection. Further clinical investigations are required to evaluate the clinical relevance of the gulf between bioactivity and solubility.


Asunto(s)
Materiales de Obturación del Conducto Radicular , Compuestos de Calcio , Combinación de Medicamentos , Resinas Epoxi , Ensayo de Materiales , Obturación del Conducto Radicular , Silicatos
8.
Clin Oral Investig ; 22(2): 811-817, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28643130

RESUMEN

OBJECTIVES: The objective of the study was to compare the retreatability of three calcium silicate-containing sealers (BioRoot RCS, MTA Fillapex, Endo C.P.M.) and an epoxy resin-based sealer (AH Plus) with different root canal instruments (Hedström files, Reciproc R40, Mtwo retreatment file R 25/.05 + Mtwo 40/.06, and F6 SkyTaper) concerning sealer remnants and retreatment time. MATERIALS AND METHODS: Root canals of 192 teeth were instrumented with Reciproc R40. All root canals were obturated using the single-cone technique with Reciproc R40 gutta-percha and one of the sealers (n = 48 per sealer). Two months later, retreatment was performed using one of the mentioned instruments (n = 12 per instrument and sealer). The roots were split longitudinally, and both halves were investigated using light microscopy. The percentage of sealer remnants covering the root canal wall was evaluated using the software ImageJ. The time required for retreatment was recorded. Statistical analysis was performed using two-way ANOVA and Student-Newman-Keuls post hoc test. RESULTS: Regarding the percentage of root canal filling remnants as well as retreatment time, two-way ANOVA indicated that the results were significantly affected by the sealer (p < 0.001) and by the instrument used (p < 0.05). Overall, the use of AH Plus was associated with significantly more remnants compared to all other sealers (p < 0.001) and F6 SkyTaper instruments allowed significantly faster retreatment than the other instruments (p < 0.05). CONCLUSION: The retreatability of calcium silicate-containing sealers was better compared to AH Plus as less sealer remnants and shorter retreatment times were observed. Retreatment with engine-driven NiTi instruments was superior compared to hand instrumentation. CLINICAL RELEVANCE: Engine-driven NiTi instruments are better suited to remove root canal fillings than stainless steel Hedström files.


Asunto(s)
Materiales de Obturación del Conducto Radicular/química , Obturación del Conducto Radicular/instrumentación , Compuestos de Aluminio/química , Materiales Biocompatibles , Compuestos de Calcio/química , Combinación de Medicamentos , Resinas Epoxi/química , Humanos , Procesamiento de Imagen Asistido por Computador , Técnicas In Vitro , Óxidos/química , Retratamiento , Silicatos/química
9.
Materials (Basel) ; 17(4)2024 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-38399077

RESUMEN

Reciprocating motion expands the lifetime of endodontic instruments during the preparation of severely curved root canals. This study aimed to investigate the time to fracture (TTF) and number of cycles to failure (NCF) of different reciprocating instruments (n = 20 in each group) at body temperature using a dynamic testing model (amplitude = 3 mm). Reciproc Blue (RPB), size 25/.08, WaveOne Gold (WOG) 25/.07, Procodile (Proc) 25/.06, R-Motion (RM_06) 25/.06 and R-Motion (RM_04) 30/.04 instruments were tested in their specific reciprocating motion in artificial matching root canals (size of the instrument ± 0.02 mm; angle of curvature 60°, radius 5.0 mm, and centre of curvature 5.0 mm from apical endpoint). The number of fractured instruments, TTF, NCF, the and lengths of the fractured instruments were recorded and statistically analysed using the Chi-Square or Kruskal-Wallis test. Both TTF (median 720, 643, 562, 406, 254 s) and the NCF (3600, 3215, 2810, 2032, 1482 cycles) decreased in the following order RM_06 > RPB > RM_04 > Proc > WOG with partially significant differences. During testing, only six RM_06 instruments fractured, whereas 16/20 (RPB), 18/20 (Proc), and 20/20 (RM_04, WOG) fractures were recorded (p < 0.05). Within the limitations of the present study, blue-coloured RPB and RM instruments exhibited a significantly superior cyclic fatigue resistance compared to SE-NiTi and Gold-wire instruments. Heat treatment, cross-sectional design and core mass significantly influenced the longevity of reciprocating instruments in cyclic dynamic testing.

10.
J Endod ; 50(5): 644-650.e1, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38382735

RESUMEN

INTRODUCTION: This study aimed to evaluate the removal of a biofilm-mimicking hydrogel from isthmus structures in a simulated complex root canal system consisting of 2 curved root canals by Laser-activated irrigation (LAI, AdvErl Evo, Morita) and mechanical activation techniques. METHODS: A 3D-printed root canal model with 2 parallel root canals (60°-curvature, radius 5 mm, dimension 25/.06) with a total length of 20 mm connected via isthmuses (2.5 × 0.4 × 0.2 mm) at 5 mm and 8 mm from the apical endpoint and with lateral canals (diameter 0.2 mm) in all directions at 2, 5, and 8 mm from the apex was filled with a colored biofilm-mimicking hydrogel. Irrigation protocols under continuous irrigation with distilled water (3 × 20s per root canal; 3 ml/20s; n = 20) included conventional needle irrigation (=NI); manual agitation (=MA, gutta-percha point 25/.06); EndoActivator (=SAI-EA, 25/.04); EDDY (=SAI-E, 25/.04); ultrasonically-activated irrigation (=UAI) and LAI (Er:YAG-laser; P400FL tip at canal entrance; 25pps, 50 mJ, 300µs). Removal of the hydrogel was determined as a percentage via standardized photos through a microscope. Statistical analysis was performed using Kruskal-Wallis and Conover tests (P = .05). RESULTS: Laser-activated irrigation (LAI) was associated with the greatest removal of hydrogel from the entire root canal system (P < .05), followed by SAI-E. No significant differences were reported for the coronal isthmus between LAI, SAI-E, NI, and MA (P > .05), but inferior results for SAI-EA and UAI (P < .05). In the apical isthmus, all techniques outperformed UAI (P < .05), with LAI, SAI-E, and NI showing the best results (P < .05). CONCLUSIONS: Laser-activated irrigation (LAI) was superior to other irrigation techniques in the entire root canal system. SAI-E and NI performed comparable to LAI in the isthmuses.


Asunto(s)
Cavidad Pulpar , Irrigantes del Conducto Radicular , Preparación del Conducto Radicular , Irrigación Terapéutica , Irrigación Terapéutica/métodos , Irrigación Terapéutica/instrumentación , Preparación del Conducto Radicular/métodos , Preparación del Conducto Radicular/instrumentación , Irrigantes del Conducto Radicular/administración & dosificación , Humanos , Biopelículas , Impresión Tridimensional
11.
Int Dent J ; 2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-39048490

RESUMEN

AIMS: Composite materials are widely used in dentistry for direct tooth restorations. However, they are highly sensitive to the working technique employed during the restorative procedure. Even minor procedural errors can have a significant impact on the quality including the longevity of the restoration. Hence the aim of this study was to determine the material preferences and analyse the clinical problems associated with direct composite restorations in a cohort of dentists. METHODS: A 20-item online questionnaire was created in English and administered 1830 general dentists and specialists in 13 countries. The first section of the questionnaire included four questions to elicit demographic data, and the second section comprised 16 questions focused on material preferences for conservative restorations, durability of composite restorations, and the most challenging stages the dentists faced during the composite restorative procedures. RESULTS: Respondents decided most often to use composite materials for the tooth restorations (OR 997.4, 95% CI 233.8-4254.8, P value <.001). Most respondents indicated that the durability of composite restorations was approximately 7 to 10 years (41.5%). Among the factors affecting durability, maintenance of a dry cavity was the most often reported reason (47.1%) and the foremost challenge faced by dentists (61.0%) during the composite restorative procedures. CONCLUSIONS: Our study confirmed that resin-based composites are the most popular material for direct restoration in many countries. Although working with this material is difficult and involves multiple steps, maintaining a dry cavity during bonding, and material application may affect the therapeutic success and durability of these restorations. Clinicians need to be attentive to this issue and be prepared to adapt their decision-making and consider opting for alternative restorative materials, if appropriate.

12.
J Dent ; 145: 105009, 2024 06.
Artículo en Inglés | MEDLINE | ID: mdl-38643866

RESUMEN

OBJECTIVES: Resin-based composites (RBCs) evolved into favoured materials for teeth restorations, marking a significant change in dental practice. Despite many advantages, RBCs exhibit various limitations in their physical and chemical properties. Therefore, we assessed the dentists' awareness of possible complications after direct composite restorations and their opinions about this material. METHODS: The online questionnaire was created in English in May 2023. A 16-item survey was dedicated to general dentists and specialists. The first section included four questions related to demographic characteristics. The second section comprised twelve questions and focused on awareness of potential side effects of composite restorations, the most crucial advantages and disadvantages of composite resins, and the frequency of experienced clinical complications after the application of composite materials. RESULTS: A total of 1830 dentists from 13 countries took part in the survey. Dentists most often declared awareness of low adhesion to the dentine (77.5 %) and, most rarely, solubility in oral fluids (42.6 %). Aesthetics was identified as the main advantage of composite fillings (79 %), followed by the possibility of repair (59 %) and adhesion to enamel (57 %). Polymerisation shrinkage was a major disadvantage for most countries (70 % overall). Analysing the declared potential clinical complications for all countries, statistically significant findings were obtained for marginal discolouration (OR=2.982, 95 % CI: 1.321-6.730, p-value=0.009) and borderline significance for secondary caries (OR=1.814, 95 % CI: 0.964-3.415, p-value=0.065). CONCLUSIONS: Dentists value aesthetics and repairability but are aware of shrinkage and experience discolouration. The issue of toxicity and solubility seems to be the least known to dentists. CLINICAL SIGNIFICANCE: Dentists should use RBCs with critical caution due to possible side effects. Despite the undoubted aesthetics of direct composite restorations, it is necessary to remember potential clinical complications such as marginal discolouration or secondary caries.


Asunto(s)
Resinas Compuestas , Restauración Dental Permanente , Odontólogos , Resinas Compuestas/efectos adversos , Resinas Compuestas/química , Humanos , Restauración Dental Permanente/efectos adversos , Odontólogos/psicología , Encuestas y Cuestionarios , Femenino , Masculino , Materiales Dentales/efectos adversos , Materiales Dentales/química , Adulto , Estética Dental , Persona de Mediana Edad , Polimerizacion , Reparación de Restauración Dental
13.
J Endod ; 2023 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-37586645

RESUMEN

INTRODUCTION: To compare the biofilm-mimicking hydrogel removal efficiency of laser-activated irrigation (LAI) with five other irrigation techniques in simulated curved root canals with lateral canals. METHODS: Three-dimensional-printed root canal models (60°-curvature, radius 5 mm; dimension 25/.06) with a total length of 20 mm and lateral canals in all directions at 2, 5, and 8 mm (diameter 0.2 mm) from the apex were filled with a colored biofilm-mimicking hydrogel. The following protocols (each 3 × 20 seconds continuous irrigation with distilled water 3 ml/20 seconds; n = 20) were carried out: conventional needle irrigation; manual agitation ([MA], gutta-percha point 25/.06); EndoActivator (=sonically-activated irrigation EndoActivator, 25/.04); EDDY (=sonically-activated irrigation EDDY [SAI-E]; 25/.04); ultrasonically-activated irrigation and LAI (Erbium-doped Yttrium Aluminum Garnet laser; P400FL tip at canal entrance; 25 pps, 50 mJ, 300 µs). Standardized photos were taken with a microscope and the removal of the hydrogel was determined as a percentage for the entire system, the main canal and the lateral canals. Statistical analysis was performed using analysis of variance and Scheffé test (P = .05). RESULTS: LAI (89.3% ± 5.9%) showed the greatest hydrogel removal followed by SAI-E (65.5% ± 3.3%) and ultrasonically-activated irrigation (59.1% ± 4.7%), with significant differences between these groups (P < .05). Needle irrigation, MA, and sonically-activated irrigation EndoActivator performed equally (P > .05) and obtained the significantly lowest values (P < .05). LAI and SAI-E showed the significantly best hydrogel removal from the main canal (P < .05). At all three levels, LAI removed significantly more hydrogel from the lateral canals than all other techniques (P < .05). CONCLUSIONS: LAI was superior to other techniques in both the entire system and the lateral canals in removing the hydrogel. SAI-E achieved comparable results in the main canal.

14.
J Endod ; 49(5): 549-558, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36863567

RESUMEN

BACKGROUND: An additional canal found in the mandibular first molar (M1M) is the middle mesial canal (MMC), which is often missed during root canal treatment. In this study, the prevalence of MMC in M1M on cone-beam computed tomography (CBCT) images was evaluated in 15 countries, along with the effect of some demographic factors on its prevalence. METHODS: Deidentified CBCT images were scanned retrospectively, and the ones including bilateral M1Ms were included in the study. A written and video instruction program explaining the protocol to be followed step-by-step was provided to all observers to calibrate them. The CBCT imaging screening procedure consisted of evaluating three planes (coronal, sagittal, and axial) after a 3-dimensional alignment of the long axis of the root(s). The presence of an MMC in M1Ms (yes/no) was identified and recorded. RESULTS: In total, 6304 CBCTs, representing 12,608 M1Ms, were evaluated. A significant difference was found between countries (P < .05). MMC prevalence ranged from 1% to 23%, and the overall prevalence was 7% (95% confidence interval [CI]: 5%-9%). No significant differences were found between the left and right M1M (odds ratio = 1.09, 95% CI: 0.93, 1.27; P > .05) or between genders (odds ratio= 1.07, 95% CI: 0.91, 1.27; P > .05). As for the age groups, no significant differences were found (P > .05). CONCLUSIONS: The prevalence of MMC varies by ethnicity, but it is generally estimated at 7% worldwide. Physicians must pay close attention to the presence of MMC in M1M, especially for opposite M1Ms, due to the prevalence of MMC being significantly bilateral.


Asunto(s)
Cavidad Pulpar , Raíz del Diente , Humanos , Masculino , Femenino , Cavidad Pulpar/diagnóstico por imagen , Estudios Transversales , Prevalencia , Estudios Retrospectivos , Mandíbula/diagnóstico por imagen , Diente Molar/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico/métodos
15.
Quintessence Int ; 53(5): 384-392, 2022 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-35119238

RESUMEN

OBJECTIVES: The aim of this in vitro study was to compare the shear bond strength of a CAD/CAM resin-based composite restoration material with a lithium-disilicate-ceramic restoration material on human dentin. In addition, the influence of the chosen adhesive system should be investigated. METHOD AND MATERIALS: Thirty cylindrical specimens each were fabricated from the composite resin-based material Grandio Blocs (GB) and the ceramic IPS e.max CAD (IEM). In each case, 15 specimens were bonded to human dentin samples using the adhesive system recommended and provided by the manufacturer. For 15 additional specimens, the adhesive systems were interchanged. After water storage (4 weeks) and thermocycling (5,000 cycles between 5°C and 55°C), the shear bond strength, the fracture modes, and the Adhesive Remnant Index (ARI) were determined. All data were statistically evaluated (Kruskal-Wallis test; P < .05). RESULTS: The shear bond strength of IEM in combination with the manufacturer's recommended adhesive system was statistically significantly higher than in those of all other groups (P < .05), resulting in 39.24 ± 7.73 N/mm2. For IEM, adhesive fracture mode was the only mode found, while adhesive and mixed fracture modes occurred in both GB groups. Significantly more adhesive/restoration material remnants (ARI) remained on the dentin surfaces in both GB groups (P < .05). CONCLUSION: For IEM the adhesive system recommended by the manufacturer should be used. For the GB samples, the choice of adhesive system had no influence on the shear bond strength. With GB, fracture may occur partly within the material under heavy load.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos de Resina , Cerámica/química , Resinas Compuestas , Recubrimiento Dental Adhesivo/métodos , Porcelana Dental/química , Dentina , Humanos , Ensayo de Materiales , Cementos de Resina/química , Resistencia al Corte , Propiedades de Superficie
16.
Materials (Basel) ; 15(20)2022 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-36295385

RESUMEN

This study aimed to investigate the short- and long-term solubility, alkalizing potential, and suitability for warm-vertical compaction of AH Plus Bioceramic Sealer (AHBC), and Total Fill BC Sealer (TFBC) compared to the epoxy-resin sealer AH Plus (AHP). A solubility test was performed according to ISO specification 6876 and further similar to ISO requirements over a period of 1 month in distilled water (AD) and 4 months in phosphate-buffered saline (PBS). The pH of the immersion solution was determined weekly. Sealers were exposed to thermal treatment at 37, 57, 67, and 97 °C for 30 s. Furthermore, heat treatment at 97 °C was performed for 180 s to simulate inappropriate implementation of warm vertical filling techniques. Physical properties (setting time, flow, film thickness according to ISO 6876) and chemical properties (Fourier transformed infrared spectroscopy) were assessed. AHBC and TFBC were associated with significantly higher solubility than AHP over 1 month in AD and 4 months in PBS (p < 0.05). AHBC and TFBC both reached high initial alkaline pH, while TFBC was associated with a longer-lasting alkaline potential than AHBC. Initial pH of AHBC and TFBC was higher in AD than in PBS. None of the sealers were compromised by thermal treatment.

17.
Aust Endod J ; 47(1): 59-66, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33159489

RESUMEN

Antibacterial activity and tissue dilution of sodium hypochlorite (NaOCl) are improved by moderately heating the irrigant. Temperature can be risen by preheating or intracanal activation. To assess intracanal temperature development of NaOCl during irrigation activation and syringe activation (SI) in a closed system at 37°C, Type-K thermocouples were inserted close to the root canal of one human single-rooted maxillary canine at the apex and 5 and 10 mm from the apical foramen via drilled holes. The root was positioned in a plastic vial filled with alginate simulating surrounding biological structures. Experiments were performed in a closed environment at 37°C (n = 14): EA: EndoActivator (Dentsply Sirona), EDDY: EDDY (VDW), PUI: passive ultrasonic irrigation, PIPS: Photon-induced photoacoustic streaming (Fotona), S60: SI of 60°C-NaOCl, S45: SI of 45°C-NaOCl, and S20: SI of 20°C-NaOCl. S45, PUI and EDDY lead to minor intracanal temperature increases. EA and PIPS did not influence the intracanal temperature. SI with 60°C-NaOCl resulted in higher intracanal temperatures than activation systems. Temperature dissipation into simulated tissues buffered intracanal temperature changes.


Asunto(s)
Irrigantes del Conducto Radicular , Preparación del Conducto Radicular , Cavidad Pulpar , Humanos , Rayos Láser , Hipoclorito de Sodio , Jeringas , Temperatura , Irrigación Terapéutica
18.
Materials (Basel) ; 14(19)2021 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-34640131

RESUMEN

Instrument failure during root canal preparation is still a concern among endodontists. However, it remains unclear whether the use of more martensitic alloys or the cross-sectional design parameters (i.e., core mass) significantly improve fracture resistance. The aim of the study was to evaluate the impact of core mass and alloy on dynamic cyclic fatigue resistance of nickel-titanium endodontic instruments in matching artificial canals at body temperature. Two groups were tested. (A) taper 0.04: F360 (Komet, Lemgo, Germany), Twisted file (Sybron Endo, Glendora, CA, USA) (=TF), JIZAI (Mani, Tochigi, Japan) (=J_04) (all size #25) and the variable tapered TruNatomy (Dentsply, Ballaigues, Switzerland) (size #26) (=TN). (B) size #25; taper 0.06: (Mtwo (VDW, Munich, Germany), JIZAI (Mani) (=J_06), and variable tapered Hyflex EDM OneFile (Coltene Whaledent, Altstätten, Switzerland) (=HF). Time, number of cycles to fracture (NCF), and number and length of fractured fragments were recorded and statistically analysed using ANOVA Student-Newman-Keuls, Kruskal-Wallis or Chi-square test (significance level = 0.05). (A) TN showed the significantly shortest time until fracture, followed by TF, F360 and J_04 which also differed significantly, while NCF showed the following order: F360 < TN < TF < J_04 (p < 0.05). Only one J_04 but all instruments of the other groups fractured within the test-limit of 10 min. (B) Mtwo was significantly inferior concerning time until fracture and NCF, compared to J_06 and HF (p < 0.05), which did not differ significantly (p > 0.05). While all Mtwo instruments fractured, only four instruments failed in the other groups (p < 0.05). Within the limitations of this study, alloy and cross-sectional design (i.e., core mass) were critical factors regarding instrument failure, but none of these factors could be determined as a main parameter for increased or decreased time, and cycles to fracture. Rather, it seemed to be the interaction of multiple factors (e.g., longitudinal and cross-sectional design, alloy, and rotational speed) that was responsible for differences in the time and cycles to fracture. Nonetheless, all instruments had lifetimes that allow safe clinical use. However, the superiority or inferiority of an instrument with regard to cyclic fatigue based on laboratory results-even when identical trajectories are guaranteed-may be considered questionable, as the characteristics and design parameters of the instruments vary considerably, and the experimental setups lack additional clinical parameters and thus clinical relevance.

19.
J Clin Med ; 10(19)2021 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-34640456

RESUMEN

Sealer staining using rhodamine B dye to investigate the penetration depth of endodontic sealers was proven unsuitable for this purpose. This study aimed to investigate the sealer penetration depth into dentinal tubules by scanning electron microscopy (SEM). Root canals of 52 human upper central incisors were instrumented using the ProTaper Gold NiTi system (Dentsply Sirona, York, PA, USA) up to size F3. After irrigation with sodium hypochlorite and citric acid combined with ultrasonic activation, the root canals were either filled using the epoxy resin sealer AH Plus (Dentsply Sirona) or the calcium silicate-based sealer Total Fill BC Sealer HiFlow (TFHF, FKG Dentaire, La Chaux-de-Fonds, Switzerland) by warm vertical compaction. Root slices of 1 mm thickness were obtained at 2 to 3, 5 to 6 and 8 to 9 mm from the apex. The root slices were investigated for sealer penetration into the dentinal tubules using SEM according to four root quadrants (buccal, mesial, oral, distal). Statistical analysis was performed by the Kruskal-Wallis test (p = 0.05) as data were not normally distributed according to the Shapiro-Wilk test. AH Plus penetrated significantly deeper into the dentinal tubules compared to TFHF at each root level (p < 0.05). Dentinal sealer penetration was deeper in the bucco-oral direction compared to the mesio-distal direction. AH Plus penetrated deeper into dentinal tubules than TFHF. Warm vertical compaction exerting high pressure on the root canal filling material is not able to press sealers deep into dentinal tubules as penetration depth values did not exceed a mean of 110 µm in SEM.

20.
Materials (Basel) ; 14(5)2021 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-33668333

RESUMEN

The aim was to evaluate the canal straightening and the amount of apically extruded debris associated with five rotary nickel-titanium when preparing curved root canals. A total of 100 root canals in extracted human teeth (angles of curvatures 20°-30°; radii 5.9-13.5 mm) were divided into five groups (n = 20/group). The groups were balanced with respect to the angle and the radius of canal curvature. The root canals were prepared using conventional austenite 55-NiTi alloy instruments F360, F6 SkyTaper (both Komet, Lemgo, Germany), and the heat-treated NiTi Jizai, Silk-Complex and Silk-Standard instruments (all Mani, Tochigi, Japan) to an apical size 25. The amount of extruded debris was assessed with a micro balance. Statistical analysis was performed using Kruskal-Wallis test with Bonferroni correction at a significance level of p < 0.05. During canal preparation, neither instrument fractures nor procedural preparation errors were noticed. Regarding canal straightening, the use of Jizai instruments resulted in the significantly lowest straightening (p < 0.05), while no significant differences were obtained between all other groups (p > 0.05). Regarding the amount of apically extruded debris, no significant differences between all groups were obtained (p > 0.05). Within the limitations of this study, all instruments performed well, and especially the Jizai instruments showed an excellent shaping ability.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA