Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Nano Lett ; 19(8): 4861-4865, 2019 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-31265785

RESUMEN

Measurement of the angular and overlap dependence of the conduction between two identical carbon nanotubes (CNTs), with the same diameter and chirality, has only been possible through theoretical calculations; however, our observation of increased resistance adjacent to the junction between two CNTs facilitates such measurements. Since electrical resistance was found to increase with increased diameter ratio, applying 10 V to one of dissimilar diameter CNTs results in cleavage at the junction. Manipulation of the resulting identical CNTs (created by cutting a single CNT) allows for the direct measurement of the angular and parallel overlap conduction. Angular (13° < θ < 63°) dependence shows two minima (22° and 44°) and a maximum at 30°, and conduction between parallel CNTs increases with overall tip separation but shows a sinusoidal relationship with contact length, consistent with the concept of atomic scale registry.

2.
Analyst ; 143(24): 6014-6024, 2018 Dec 03.
Artículo en Inglés | MEDLINE | ID: mdl-30398225

RESUMEN

Vibrational spectroscopic techniques such as Raman spectroscopy and Fourier transform infrared spectroscopy (FTIR) have huge potential for the analysis of biological specimens. The techniques allow the user to gain label-free, non-destructive biochemical information about a given sample. Previous studies using vibrational spectroscopy with the specific application of diagnosing colorectal diseases such as cancer have mainly focused on in vivo or in vitro studies of tissue specimens using microscopy or probe based techniques. There have been few studies of vibrational spectroscopic techniques based on the analysis of blood serum for the advancement of colorectal cancer diagnostics. With growing interest in the field of liquid biopsies, this study presents the development of a high-throughput (HT) serum Raman spectroscopy platform and methodology and compares dry and liquid data acquisition of serum samples. This work considers factors contributing to translatability of the methodologies such as HT design, inter-user variability and sample handling effects on diagnostic capability. The HT Raman methods were tested on a pilot dataset of serum from 30 cancer patients and 30 matched control patients using statistical analysis via cross-validated PLS-DA with a maximum achieved a sensitivity of 83% and specificity of 83% for detecting colorectal cancer.


Asunto(s)
Análisis Químico de la Sangre/métodos , Neoplasias Colorrectales/diagnóstico , Espectrometría Raman/métodos , Anciano , Neoplasias Colorrectales/sangre , Análisis Discriminante , Femenino , Humanos , Análisis de los Mínimos Cuadrados , Masculino , Persona de Mediana Edad , Temperatura
3.
Nanotechnology ; 29(16): 165701, 2018 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-29425112

RESUMEN

ZnO nanosheets are polycrystalline nanostructures that are used in devices including solar cells and gas sensors. However, for efficient and reproducible device operation and contact behaviour the conductivity characteristics must be controlled and surface contaminants removed. Here we use low doses of argon bombardment to remove surface contamination and make reproducible lower resistance contacts. Higher doses strip the surface of the nanosheets altering the contact type from near-ohmic to rectifying by removing the donor-type defects, which photoluminescence shows to be concentrated in the near-surface. Controlled doses of argon treatments allow nanosheets to be customised for device formation.

4.
BJGP Open ; 7(1)2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36332909

RESUMEN

BACKGROUND: The majority of colorectal cancers (CRCs) are detected after symptomatic presentation to primary care. Given the shared symptoms of CRC and benign disorders, it is challenging to manage the risk of missed diagnosis. Colonoscopy resources cannot keep pace with increasing demand. There is a pressing need for access to simple triage tools in primary care to help prioritise patients for referral. AIM: To evaluate the performance of a novel spectroscopy-based CRC blood test in primary care. DESIGN & SETTING: Mixed-methods pilot study of test performance and GP focus group discussions in South Wales. METHOD: Patients on the urgent suspected cancer (USC) pathway were recruited for the Raman spectroscopy (RS) test coupled to machine learning classification ('Raman-CRC') to identify CRC within the referred population. Qualitative focus group work evaluated the acceptability of the test in primary care by thematic analysis of focus group theorising. RESULTS: A total of 532 patients aged ≥50 years referred on the USC pathway were recruited from 27 GP practices. Twenty-nine patients (5.0%) were diagnosed with CRC. Raman-CRC identified CRC with sensitivity 95.7%, specificity 69.3% with area under curve (AUC) of 0.80 compared with colonoscopy as the reference test (248 patients). Stage I and II cancers were detected with 78.6% sensitivity. Focus group themes underlined the convenience of a blood test for the patient and the test's value as a risk assessment tool in primary care. CONCLUSION: The findings support this novel, non-invasive, blood-based method to prioritise those patients most likely to have CRC. Raman-CRC may accelerate access to diagnosis with potential to improve cancer outcomes.

5.
Appl Spectrosc ; 76(4): 496-507, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35255720

RESUMEN

Spectral pre-processing is an essential step in data analysis for biomedical diagnostic applications of Raman spectroscopy, allowing the removal of undesirable spectral contributions that could mask biological information used for diagnosis. However, due to the specificity of pre-processing for a given sample type and the vast number of potential pre-processing combinations, optimisation of pre-processing via a manual "trial and error" format is often time intensive with no guarantee that the chosen method is optimal for the sample type. Here we present the use of high-performance computing (HPC) to trial over 2.4 million pre-processing permutations to demonstrate the optimisation on the pre-processing of human serum Raman spectra for colorectal cancer detection. The effect of varying pre-processing order, using extended multiplicative scatter correction, spectral smoothing, baseline correction, binning and normalization was considered. Permutations were assessed on their ability to detect patients with disease using a random forest (RF) algorithm trained with 102 patients (510 spectra) and independently tested with a set of 439 patients (1317 spectra) in a primary care patient cohort. Optimising via HPC enables improved performance in diagnostic abilities, with sensitivity increasing by 14.6%, specificity increasing by 6.9%, positive predictive value increasing by 3.4%, and negative predictive value increasing by 2.4% when compared to a standard pre-processing optimisation. Ultimate values of these metrics are very important for diagnostic adoption, and once diagnostics demonstrate good accuracy these types of optimisations can make a significant difference to roll-out of a test and demonstrating advantages over existing tests. We also provide tips/recommendations for pre-processing optimisation without the use of HPC. From the HPC permutations, recommendations for appropriate parameter constraints for conducting a more basic pre-processing optimisation are also detailed, thus helping model development for researchers not having access to HPC.


Asunto(s)
Algoritmos , Neoplasias Colorrectales , Neoplasias Colorrectales/diagnóstico , Humanos , Espectrometría Raman/métodos
6.
Front Glob Womens Health ; 1: 610582, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-34816172

RESUMEN

Preeclampsia (PE) is a common obstetric disorder typically affecting 2-8% of all pregnancies and can lead to several adverse obstetric outcomes for both mother and fetus with the greatest burden of severe outcomes in low middle-income countries (LMICs), therefore, screening for PE is vital. Globally, screening is based on maternal characteristics and medical history which are nonspecific for the disorder. In 2004, the World Health Organization acknowledged that no clinically useful test was able to predict the onset of PE, which prompted a universal search for alternative means of screening. Over the past decade or so, emphasis has been placed on the use of maternal characteristics in conjunction with biomarkers of disease combined into predictive algorithms, however these are yet to transition into the clinic and are cost prohibitive in LMICs. As a result, the screening paradigm for PE remains unchanged. It is evident that novel approaches are needed. Vibrational spectroscopy, specifically Raman spectroscopy and Fourier-transform infrared spectroscopy (FTIR), could provide better alternatives suited for implementation in low resource settings as no specialized reagents are required for conventional approaches and there is a drive to portable platforms usable in both urban and rual community settings. These techniques are based on light scattering and absorption, respectively, allowing detailed molecular analysis of samples to produce a unique molecular fingerprint of diseased states. The specificity of vibrational spectroscopy might well make it suited for application in other obstetric disorders such as gestational diabetes mellitus and obstetric cholestasis. In this review, we summarize current approaches sought as alternatives to current screening methodologies and introduce how vibrational spectroscopy could offer superior screening and diagnostic paradigms in obstetric care. Additionally, we propose a real benefit of such tools in LMICs where limited resources battle the higher prevalence of obstetric disorders.

7.
Ultramicroscopy ; 107(4-5): 308-12, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17034949

RESUMEN

Scanning near-field optical microscopy (SNOM) has been successfully employed to generate high resolution (<100nm) fluorescence images of directly tagged human chromosomes. Direct tagging, fluorescence in-situ hybridisation processes (with and without amplification) are investigated and their fluorescence response to near-field excitation are compared. Using the simultaneous topography mode of SNOM, chromosome morphology was seen to differ as a result of the two processes; with chromatin collapse more extensive when the amplified direct tagging procedure was used. The results are discussed in the context of developing locus specific direct tags together with high resolution SNOM imaging for the observation of chromosome aberrations.


Asunto(s)
Cromosomas Humanos Par 1/química , Fluoresceína-5-Isotiocianato/química , Microscopía Fluorescente/métodos , Pintura Cromosómica , Humanos , Linfocitos/ultraestructura
8.
World J Gastrointest Oncol ; 8(5): 427-38, 2016 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-27190582

RESUMEN

Colorectal cancer (CRC) is the fourth most common cancer in the United Kingdom and is the second largest cause of cancer related death in the United Kingdom after lung cancer. Currently in the United Kingdom there is not a diagnostic test that has sufficient differentiation between patients with cancer and those without cancer so the current referral system relies on symptomatic presentation in a primary care setting. Raman spectroscopy and surface enhanced Raman spectroscopy (SERS) are forms of vibrational spectroscopy that offer a non-destructive method to gain molecular information about biological samples. The techniques offer a wide range of applications from in vivo or in vitro diagnostics using endoscopic probes, to the use of micro-spectrometers for analysis of biofluids. The techniques have the potential to detect molecular changes prior to any morphological changes occurring in the tissue and therefore could offer many possibilities to aid the detection of CRC. The purpose of this review is to look at the current state of diagnostic technology in the United Kingdom. The development of Raman spectroscopy and SERS in clinical applications relation for CRC will then be discussed. Finally, future areas of research of Raman/SERS as a clinical tool for the diagnosis of CRC are also discussed.

9.
Nanotoxicology ; 7(2): 144-56, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22263934

RESUMEN

Single-walled carbon nanotubes (SWCNTs) have recently attracted great attention because of their fibrous structure and high aspect ratio. Here the genotoxic potential of 400-800 nm, 1-3 µm and 5-30 µm SWCNT with respect to their geometry and surface characteristics was studied. Following thorough physico-chemical characterisation, human bronchial epithelial (BEAS-2B) and lymphoblastoid (MCL-5) cells were treated with SWCNT for 24 or 48 h. This showed significant increases in micronucleus frequency in a time- and dose-dependent manner in both cell types in the absence of cytotoxicity. Over the same dose range, only 1-3 µm SWCNT gave rise to significant increases in hprt point mutations at doses ≥25 µg/ml. Cellular 2,7-dichlorodihydrofluoresceindiacetate (DCFH-DA) fluorescence assay and RT-PCR for oxidative pathway gene profiling revealed a possible oxidative mechanism for the genotoxicity observed in the 1-3 µm SWCNT. Consequently, this study has demonstrated that SWCNT genotoxicity is dependent on its secondary structure under experimental conditions and oxidative stress alone cannot account for the observed damage.


Asunto(s)
Linfocitos/efectos de los fármacos , Micronúcleos con Defecto Cromosómico/inducido químicamente , Mutágenos/toxicidad , Nanotubos de Carbono/toxicidad , Mucosa Respiratoria/efectos de los fármacos , Línea Celular Tumoral , Supervivencia Celular/efectos de los fármacos , Daño del ADN , Relación Dosis-Respuesta a Droga , Perfilación de la Expresión Génica/métodos , Regulación de la Expresión Génica/efectos de los fármacos , Humanos , Hipoxantina Fosforribosiltransferasa/genética , Linfocitos/metabolismo , Linfocitos/patología , Estructura Molecular , Mutagénesis , Mutágenos/química , Nanotubos de Carbono/química , Estrés Oxidativo/efectos de los fármacos , Tamaño de la Partícula , Mutación Puntual , Reacción en Cadena de la Polimerasa , Mucosa Respiratoria/metabolismo , Mucosa Respiratoria/patología , Relación Estructura-Actividad , Propiedades de Superficie , Factores de Tiempo
10.
PLoS One ; 7(2): e31592, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22347497

RESUMEN

In this study scanning near-field optical microscopy (SNOM) has been utilised in conjunction with quantum dot labelling to interrogate the biomolecular composition of cell membranes. The technique overcomes the limits of optical diffraction found in standard fluorescence microscopy and also yields vital topographic information. The technique has been applied to investigate cell-cell adhesion in human epithelial cells. This has been realised through immunofluorescence labelling of the cell-cell adhesion protein E-cadherin. Moreover, a dual labelling protocol has been optimised to facilitate a comparative study of the adhesion mechanisms and the effect of aberrant adhesion protein expression in both healthy and cancerous epithelial cells. This study reports clear differences in the morphology and phenotype of healthy and cancerous cells. In healthy prostate epithelial cells (PNT2), E-cadherin was predominantly located around the cell periphery and within filopodial extensions. The presence of E-cadherin appeared to be enhanced when cell-cell contact was established. In contrast, examination of metastatic prostate adenocarcinoma cells (PC-3) revealed no E-cadherin labelling around the periphery of the cells. This lack of functional E-cadherin in PC-3 cells coincided with a markedly different morphology and PC-3 cells were not found to form close cell-cell associations with their neighbours. We have demonstrated that with a fully optimised sample preparation methodology, multiplexed quantum dot labelling in conjunction with SNOM imaging can be successfully applied to interrogate biomolecular localisation within delicate cellular membranes.


Asunto(s)
Microscopía/métodos , Neoplasias de la Próstata/patología , Puntos Cuánticos , Cadherinas/análisis , Adhesión Celular , Línea Celular Tumoral , Membrana Celular/química , Células Epiteliales , Humanos , Masculino , Neoplasias de la Próstata/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA