RESUMEN
Quantiferon-TB Gold Plus (QFT-Plus) is an interferon gamma release assay used to diagnose latent tuberculosis (LTB). A borderline range (0.20 to 0.99 IU/ml) around the cutoff (0.35 IU/ml) has been suggested for the earlier QFT version. Our aims were to evaluate the borderline range for QFT-Plus and the contribution of the new TB2 antigen tube. QFT-Plus results were collected from clinical laboratories in Sweden and linked to incident active TB within 3 to 24 months using the national TB registry. Among QFT-Plus results from 58,539 patients, 83% were negative (<0.20 IU/ml), 2.4% were borderline negative (0.20 to 0.34 IU/ml), 3.4% were borderline positive (0.35 to 0.99 IU/ml), 9.6% were positive (≥1.0 IU/ml), and 1.6% were indeterminate. Follow-up tests after initial borderline results were negative (<0.20 IU/ml) in 38.3%, without any cases of incident active TB within 2 years. Applying the 0.35-IU/ml cutoff, 1.5% of TB1 and TB2 results were discrepant, of which 52% were within the borderline range. A TB2 result of ≥0.35 IU/ml with a TB1 result of <0.20 IU/ml was found in 0.4% (231/58,539) of all included baseline QFT-Plus test results, including 1.8% (1/55) of incident TB cases. A borderline range for QFT-Plus is clinically useful as more than one-third of those with borderline results are convincingly negative upon retesting, without developing incident active TB. The TB2 tube contribution to LTB diagnosis appears limited.
Asunto(s)
Tuberculosis Latente , Mycobacterium tuberculosis , Humanos , Interferón gamma , Ensayos de Liberación de Interferón gamma , Tuberculosis Latente/diagnósticoRESUMEN
Polymerase chain reaction (PCR) detection has become the gold standard for diagnosis and typing of enterovirus (EV) and human parechovirus (HPeV) infections. Its effectiveness depends critically on using the appropriate sample types and high assay sensitivity as viral loads in cerebrospinal fluid samples from meningitis and sepsis clinical presentation can be extremely low. This study evaluated the sensitivity and specificity of currently used commercial and in-house diagnostic and typing assays. Accurately quantified RNA transcript controls were distributed to 27 diagnostic and 12 reference laboratories in 17 European countries for blinded testing. Transcripts represented the four human EV species (EV-A71, echovirus 30, coxsackie A virus 21, and EV-D68), HPeV3, and specificity controls. Reported results from 48 in-house and 15 commercial assays showed 98% detection frequencies of high copy (1000 RNA copies/5 µL) transcripts. In-house assays showed significantly greater detection frequencies of the low copy (10 copies/5 µL) EV and HPeV transcripts (81% and 86%, respectively) compared with commercial assays (56%, 50%; P = 7 × 10-5 ). EV-specific PCRs showed low cross-reactivity with human rhinovirus C (3 of 42 tests) and infrequent positivity in the negative control (2 of 63 tests). Most or all high copy EV and HPeV controls were successfully typed (88%, 100%) by reference laboratories, but showed reduced effectiveness for low copy controls (41%, 67%). Stabilized RNA transcripts provide an effective, logistically simple and inexpensive reagent for evaluation of diagnostic assay performance. The study provides reassurance of the performance of the many in-house assay formats used across Europe. However, it identified often substantially reduced sensitivities of commercial assays often used as point-of-care tests.