Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 308
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Arterioscler Thromb Vasc Biol ; 43(12): 2265-2281, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37732484

RESUMEN

BACKGROUND: Endothelial cells (ECs) are capable of quickly responding in a coordinated manner to a wide array of stresses to maintain vascular homeostasis. Loss of EC cellular adaptation may be a potential marker for cardiovascular disease and a predictor of poor response to endovascular pharmacological interventions such as drug-eluting stents. Here, we report single-cell transcriptional profiling of ECs exposed to multiple stimulus classes to evaluate EC adaptation. METHODS: Human aortic ECs were costimulated with both pathophysiological flows mimicking shear stress levels found in the human aorta (laminar and turbulent, ranging from 2.5 to 30 dynes/cm2) and clinically relevant antiproliferative drugs, namely paclitaxel and rapamycin. EC state in response to these stimuli was defined using single-cell RNA sequencing. RESULTS: We identified differentially expressed genes and inferred the TF (transcription factor) landscape modulated by flow shear stress using single-cell RNA sequencing. These flow-sensitive markers differentiated previously identified spatially distinct subpopulations of ECs in the murine aorta. Moreover, distinct transcriptional modules defined flow- and drug-responsive EC adaptation singly and in combination. Flow shear stress was the dominant driver of EC state, altering their response to pharmacological therapies. CONCLUSIONS: We showed that flow shear stress modulates the cellular capacity of ECs to respond to paclitaxel and rapamycin administration, suggesting that while responding to different flow patterns, ECs experience an impairment in their transcriptional adaptation to other stimuli.


Asunto(s)
Aorta , Células Endoteliales , Humanos , Ratones , Animales , Sirolimus/farmacología , Paclitaxel/farmacología , Análisis de Secuencia de ARN , Estrés Mecánico , Células Cultivadas
2.
Am Heart J ; 262: 66-74, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37072104

RESUMEN

BACKGROUND: Exercise in pregnancy has proven health benefits, yet the safety of exercise in patients with pre-existing cardiovascular disease (CVD) has not been established. Our aim was to determine the feasibility and safety profile of moderate intensity exercise during pregnancy in patients with CVD, compared with those without CVD. METHODS: This is a prospective single center pilot study of a moderate intensity exercise regimen, with data collection through wearable fitness trackers and personal exercise logs in pregnant patients with and without pre-existing CVD. The primary outcome was Doppler umbilical artery systolic to diastolic (S/D) ratio measured between 32 and 34 weeks' gestation. The secondary outcomes were adverse maternal and fetal events, trends in wearable fitness tracker data, C-reactive protein levels, and weight changes. RESULTS: At baseline, the CVD group (62% congenital heart disease) took part in more prepregnancy walking, less weightlifting, and had a higher body mass index compared to the control group, and on average walked 539 fewer steps per day during pregnancy than the control group. Resting heart rate (HR) was found to increase in both groups up to 30 weeks' gestation. The cardiovascular disease group displayed an overall lower exercise intensity, as measured by the ability to increase HR with exercise over resting heart rate 1 hour prior to exercise at study baseline (45% vs 59% P < .001). Umbilical artery S/D ratio was normal in both groups. No differences were seen in adverse events between groups. CONCLUSIONS: This pilot study of moderate intensity exercise in pregnant individuals with pre-existing CVD demonstrated that patients with CVD were not able to increase their HR during exercise throughout pregnancy compared to those in the control group. Although a small study group, this data supports the hypothesis that exercise interventions during pregnancy for patients with CVD are feasible without evidence abnormal fetal Doppler profiles. Further studies using wearable fitness trackers may provide the opportunity to understand how to safely tailor exercise programs to pregnant individuals with CVD.


Asunto(s)
Enfermedades Cardiovasculares , Embarazo , Femenino , Humanos , Enfermedades Cardiovasculares/terapia , Proyectos Piloto , Estudios Prospectivos , Ejercicio Físico/fisiología , Atención Prenatal
3.
EMBO Rep ; 22(6): e51169, 2021 06 04.
Artículo en Inglés | MEDLINE | ID: mdl-34031962

RESUMEN

Recent studies demonstrate that metabolic disturbance, such as augmented glycolysis, contributes to fibrosis. The molecular regulation of this metabolic perturbation in fibrosis, however, has been elusive. COUP-TFII (also known as NR2F2) is an important regulator of glucose and lipid metabolism. Its contribution to organ fibrosis is undefined. Here, we found increased COUP-TFII expression in myofibroblasts in human fibrotic kidneys, lungs, kidney organoids, and mouse kidneys after injury. Genetic ablation of COUP-TFII in mice resulted in attenuation of injury-induced kidney fibrosis. A non-biased proteomic study revealed the suppression of fatty acid oxidation and the enhancement of glycolysis pathways in COUP-TFII overexpressing fibroblasts. Overexpression of COUP-TFII in fibroblasts also induced production of alpha-smooth muscle actin (αSMA) and collagen 1. Knockout of COUP-TFII decreased glycolysis and collagen 1 levels in fibroblasts. Chip-qPCR revealed the binding of COUP-TFII on the promoter of PGC1α. Overexpression of COUP-TFII reduced the cellular level of PGC1α. Targeting COUP-TFII serves as a novel treatment approach for mitigating fibrosis in chronic kidney disease and potentially fibrosis in other organs.


Asunto(s)
Factor de Transcripción COUP II , Receptores Nucleares Huérfanos , Animales , Factor de Transcripción COUP II/genética , Factor de Transcripción COUP II/metabolismo , Fibrosis , Glucólisis/genética , Riñón , Ratones , Ratones Noqueados , Miofibroblastos , Receptores Nucleares Huérfanos/metabolismo , Proteómica
4.
Proc Natl Acad Sci U S A ; 117(22): 12368-12374, 2020 06 02.
Artículo en Inglés | MEDLINE | ID: mdl-32409608

RESUMEN

Epstein-Barr virus (EBV) is a ubiquitous human γ-herpesvirus that establishes life-long infection and increases the risk for the development of several cancers and autoimmune diseases. The mechanisms by which chronic EBV infection leads to subsequent disease remain incompletely understood. Lytic reactivation plays a central role in the development of EBV-driven cancers and may contribute to other EBV-associated diseases. Thus, the clinical use of antivirals as suppressive therapy for EBV lytic reactivation may aid efforts aimed at disease prevention. Current antivirals for EBV have shown limited clinical utility due to low potency or high toxicity, leaving open the need for potent antivirals suitable for long-term prophylaxis. In the present study, we show that tenofovir disoproxil fumarate (TDF) and tenofovir alafenamide (TAF), drugs with excellent safety profiles used clinically for HIV prevention, inhibit EBV lytic DNA replication, with respective IC50 values of 0.30 µM and 84 nM. In a cell-based assay, TAF was 35- and 24-fold and TDF was 10- and 7-fold more potent than acyclovir and penciclovir, respectively, and TAF was also twice as potent as ganciclovir. The active metabolite of tenofovir prodrugs, tenofovir-diphosphate, inhibited the incorporation of dATP into a primed DNA template by the EBV DNA polymerase in vitro. In contrast to acyclovir, treatment of cells during latency for 24 h with TAF still inhibited EBV lytic DNA replication at 72 h after drug was removed. Our results suggest that tenofovir prodrugs may be particularly effective as inhibitors of EBV lytic reactivation, and that clinical studies to address critical questions about disease prevention are warranted.


Asunto(s)
Antivirales/farmacología , Replicación del ADN/efectos de los fármacos , Infecciones por Virus de Epstein-Barr/virología , Herpesvirus Humano 4/efectos de los fármacos , Inhibidores de la Síntesis del Ácido Nucleico/farmacología , Tenofovir/farmacología , Proteínas Virales/antagonistas & inhibidores , ADN Viral/genética , ADN Viral/metabolismo , ADN Polimerasa Dirigida por ADN/genética , ADN Polimerasa Dirigida por ADN/metabolismo , Herpesvirus Humano 4/enzimología , Herpesvirus Humano 4/genética , Herpesvirus Humano 4/fisiología , Humanos , Profármacos/farmacología , Proteínas Virales/genética , Proteínas Virales/metabolismo , Replicación Viral/efectos de los fármacos
5.
Arterioscler Thromb Vasc Biol ; 41(4): 1487-1503, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33567868
6.
Nanomedicine ; 42: 102540, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35181528

RESUMEN

Ultra-high molecular weight polyethylene (UHMWPE) model implants were modified using accelerated neutral atom beam (ANAB) technology and tested for in vitro wear properties and bacteria colonization. Material characterization studies using atomic force microscopy (AFM), surface energy, and in vitro protein adsorption events were also conducted to better understand the mechanism behind such wear properties and bacteria colonization. ANAB modified UHMWPE showed significantly reduced wear properties compared to controls due to nanostructured features, greater surface energy, and improved adsorption of lubricin, a synovial fluid lubricating protein. There was significantly greater adsorption of proteins known to reduce bacteria colonization (specifically, mucin, casein, and lubricin) after 4 h on UHMWPE after ANAB treatment. Such changes in initial protein events led to significantly decreased bacteria (including methicillin resistant Staph. aureus (or MRSA), Staph. aureus, E. coli, multi-drug resistant E. coli, Pseudomonas aeruginosa and Staph. epidermidis) colonization after 24 h without resorting to antibiotic use.


Asunto(s)
Escherichia coli , Polietileno , Ensayo de Materiales , Microscopía de Fuerza Atómica , Polietileno/química , Polietilenos/química , Prótesis e Implantes
7.
J Am Soc Nephrol ; 32(4): 866-885, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33627344

RESUMEN

BACKGROUND: Few therapies prevent venous neointimal hyperplasia (VNH) and venous stenosis (VS) formation in arteriovenous fistulas (AVF). Expression of the immediate early response gene X-1 (Iex-1), also known as Ier3, is associated with VNH and stenosis in murine AVFs. The study aimed to determine if local release of Ier3 long-acting inhibitor 1α,25(OH)2D3 from poly(lactic-co-glycolic acid) (PLGA) nanoparticles embedded in a thermosensitive Pluronic F127 hydrogel (1,25 NP) could affect VNH/VS formation in a large animal model. METHODS: Immediately after AVF creation in a porcine model of renal failure, 1,25 NP or vehicle control was injected into the adventitia space of AVF outflow veins. Scanning electron microscopy and dynamic light scattering characterized drug and control nanoparticles. Animals were sacrificed 3 and 28 days later for gene expression, immunohistologic, magnetic resonance imaging and angiography, and ultrasound analyses. Whole transcriptome RNA sequencing with differential gene expression analysis was performed on outflow veins of AVF. RESULTS: Encapsulation of 1α,25(OH)2D3 in PLGA nanoparticles formed nanoparticles of uniform size that were similar to nanoparticles without 1α,25(OH)2D3. The 1,25 NP-treated AVFs exhibited lower VNH/VS, Ier3 gene expression, and IER-3, MCP-1, CD68, HIF-1α, and VEGF-A immunostaining, fibrosis, and proliferation. Blood flow and lumen area increased significantly, whereas peak systolic velocity and wall shear stress decreased. Treatment increased Young's modulus and correlated with histologic assessment of fibrosis and with no evidence of vascular calcification. RNA sequencing analysis showed changes in the expression of genes associated with inflammatory, TGFß1, and apoptotic pathways. CONCLUSIONS: Local release of 1,25 NP improves AVF flow and hemodynamics, and reduces stenosis in association with reduction in inflammation, apoptosis, and fibrosis in a porcine model of arteriovenous fistula.

8.
Circulation ; 141(23): 1859-1869, 2020 06 09.
Artículo en Inglés | MEDLINE | ID: mdl-32370548

RESUMEN

BACKGROUND: Paclitaxel-containing devices (PTXDs) significantly reduce reintervention in patients with symptomatic femoropopliteal peripheral artery disease. A recent aggregate-data meta-analysis reported increased late mortality in patients with peripheral artery disease treated with PTXDs. We performed an individual patient data meta-analysis to evaluate mortality. METHODS: Manufacturers of US Food and Drug Administration-approved and commercially available devices in the United States provided deidentified individual patient data for independent analysis. Cox proportional hazards 1-stage meta-analysis models using intention-to-treat methods were used for the primary analysis. A secondary analysis of recovered missing vital status data was performed. The impact of control crossover to PTXDs, cause-specific mortality, and drug dose mortality were assessed. RESULTS: A total of 2185 subjects and 386 deaths from 8 PTXD trials with 4-year median follow-up were identified. The primary analysis indicated a 38% (95% CI, 6% to 80%) increased relative mortality risk, corresponding to 4.6% absolute increase, at 5 years associated with PTXD use. Control and treatment arm loss to follow-up and withdrawal were 24% and 23%, respectively. With inclusion of recovered vital status data, the excess relative mortality risk was 27% (95% CI, 3%-58%). This observation was consistent across various scenarios, including as-treated analyses, with no evidence of increased risk over time with PTXDs. Mortality risk tended to be increased for all major causes of death. There were no subgroup differences. No drug dose-mortality association was identified. CONCLUSIONS: This individual patient data meta-analysis, based on the most complete available data set of mortality events from PTXD randomized controlled trials, identified an absolute 4.6% increased mortality risk associated with PTXD use.


Asunto(s)
Angioplastia de Balón/mortalidad , Análisis de Datos , Stents Liberadores de Fármacos , Paclitaxel/administración & dosificación , Enfermedad Arterial Periférica/mortalidad , Enfermedad Arterial Periférica/terapia , Angioplastia de Balón/tendencias , Stents Liberadores de Fármacos/tendencias , Humanos , Mortalidad/tendencias , Ensayos Clínicos Controlados Aleatorios como Asunto/métodos
9.
Magn Reson Med ; 86(6): 3096-3110, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34431550

RESUMEN

PURPOSE: Hemodynamic alterations are indicative of cerebrovascular disease. However, the narrow and tortuous cerebrovasculature complicates image-based assessment, especially when quantifying relative pressure. Here, we present a systematic evaluation of image-based cerebrovascular relative pressure mapping, investigating the accuracy of the routinely used reduced Bernoulli (RB), the extended unsteady Bernoulli (UB), and the full-field virtual work-energy relative pressure ( ν WERP) method. METHODS: Patient-specific in silico models were used to generate synthetic cerebrovascular 4D Flow MRI, with RB, UB, and ν WERP performance quantified as a function of spatiotemporal sampling and image noise. Cerebrovascular relative pressures were also derived in 4D Flow MRI from healthy volunteers ( n=8 ), acquired at two spatial resolutions (dx = 1.1 and 0.8 mm). RESULTS: The in silico analysis indicate that accurate relative pressure estimations are inherently coupled to spatial sampling: at dx = 1.0 mm high errors are reported for all methods; at dx = 0.5 mm ν WERP recovers relative pressures at a mean error of 0.02 ± 0.25 mm Hg, while errors remain higher for RB and UB (mean error of -2.18 ± 1.91 and -2.18 ± 1.87 mm Hg, respectively). The dependence on spatial sampling is also indicated in vivo, albeit with higher correlative dependence between resolutions using ν WERP (k = 0.64, R2 = 0.81 for dx = 1.1 vs. 0.8 mm) than with RB or UB (k = 0.04, R2 = 0.03, and k = 0.07, R2 = 0.07, respectively). CONCLUSION: Image-based full-field methods such as ν WERP enable cerebrovascular relative pressure mapping; however, accuracy is directly dependent on utilized spatial resolution.


Asunto(s)
Imagenología Tridimensional , Imagen por Resonancia Magnética , Velocidad del Flujo Sanguíneo , Simulación por Computador , Voluntarios Sanos , Hemodinámica , Humanos
10.
J Cardiovasc Magn Reson ; 23(1): 51, 2021 05 13.
Artículo en Inglés | MEDLINE | ID: mdl-33980249

RESUMEN

BACKGROUND: Chronic type B aortic dissection (TBAD) is associated with poor long-term outcome, and accurate risk stratification tools remain lacking. Pressurization of the false lumen (FL) has been recognized as central in promoting aortic growth. Several surrogate imaging-based metrics have been proposed to assess FL hemodynamics; however, their relationship to enlarging aortic dimensions remains unclear. We investigated the association between aortic growth and three cardiovascular magnetic resonance (CMR)-derived metrics of FL pressurization: false lumen ejection fraction (FLEF), maximum systolic deceleration rate (MSDR), and FL relative pressure (FL ΔPmax). METHODS: CMR/CMR angiography was performed in 12 patients with chronic dissection of the descending thoracoabdominal aorta, including contrast-enhanced CMR angiography and time-resolved three-dimensional phase-contrast CMR (4D Flow CMR). Aortic growth rate was calculated as the change in maximal aortic diameter between baseline and follow-up imaging studies over the time interval, with patients categorized as having either 'stable' (< 3 mm/year) or 'enlarging' (≥ 3 mm/year) growth. Three metrics relating to FL pressurization were defined as: (1) FLEF: the ratio between retrograde and antegrade flow at the TBAD entry tear, (2) MSDR: the absolute difference between maximum and minimum systolic acceleration in the proximal FL, and (3) FL ΔPmax: the difference in absolute pressure between aortic root and distal FL. RESULTS: FLEF was higher in enlarging TBAD (49.0 ± 17.9% vs. 10.0 ± 11.9%, p = 0.002), whereas FL ΔPmax was lower (32.2 ± 10.8 vs. 57.2 ± 12.5 mmHg/m, p = 0.017). MSDR and conventional anatomic variables did not differ significantly between groups. FLEF showed positive (r = 0.78, p = 0.003) correlation with aortic growth rate whereas FL ΔPmax showed negative correlation (r = - 0.64, p = 0.026). FLEF and FL ΔPmax remained as independent predictors of aortic growth rate after adjusting for baseline aortic diameter. CONCLUSION: Comparative analysis of three 4D flow CMR metrics of TBAD FL pressurization demonstrated that those that focusing on retrograde flow (FLEF) and relative pressure (FL ΔPmax) independently correlated with growth and differentiated patients with enlarging and stable descending aortic dissections. These results emphasize the highly variable nature of aortic hemodynamics in TBAD patients, and suggest that 4D Flow CMR derived metrics of FL pressurization may be useful to separate patients at highest and lowest risk for progressive aortic growth and complications.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Disección Aórtica/diagnóstico por imagen , Aorta , Hemodinámica , Humanos , Espectroscopía de Resonancia Magnética , Valor Predictivo de las Pruebas , Resultado del Tratamiento
11.
Proc Natl Acad Sci U S A ; 115(11): 2640-2645, 2018 03 13.
Artículo en Inglés | MEDLINE | ID: mdl-29483243

RESUMEN

Polymer-based bioresorbable scaffolds (BRS) seek to eliminate long-term complications of metal stents. However, current BRS designs bear substantially higher incidence of clinical failures, especially thrombosis, compared with metal stents. Research strategies inherited from metal stents fail to consider polymer microstructures and dynamics--issues critical to BRS. Using Raman spectroscopy, we demonstrate microstructural heterogeneities within polymeric scaffolds arising from integrated strain during fabrication and implantation. Stress generated from crimping and inflation causes loss of structural integrity even before chemical degradation, and the induced differences in crystallinity and polymer alignment across scaffolds lead to faster degradation in scaffold cores than on the surface, which further enlarge localized deformation. We postulate that these structural irregularities and asymmetric material degradation present a response to strain and thereby clinical performance different from metal stents. Unlike metal stents which stay patent and intact until catastrophic fracture, BRS exhibit loss of structural integrity almost immediately upon crimping and expansion. Irregularities in microstructure amplify these effects and can have profound clinical implications. Therefore, polymer microstructure should be considered in earliest design stages of resorbable devices, and fabrication processes must be well-designed with microscopic perspective.


Asunto(s)
Polímeros/química , Andamios del Tejido/química , Implantes Absorbibles , Animales , Materiales Biocompatibles/química , Vasos Sanguíneos/crecimiento & desarrollo , Humanos , Poliésteres/química , Espectrometría Raman
12.
Eur Heart J ; 41(27): 2556-2569, 2020 07 14.
Artículo en Inglés | MEDLINE | ID: mdl-32666097

RESUMEN

AIMS: The difference in the benefit of invasive cardiovascular interventions compared with placebo controls has not been analysed systematically. METHODS AND RESULTS: MEDLINE and Web of Science were searched through 29 March 2020. Randomized, placebo-controlled trials of invasive cardiovascular interventions (including catheter-based interventions and pacemaker-like devices) investigating predefined primary outcomes were included. Standardized mean differences (SMD) and odds ratios were calculated for continuous and dichotomous outcomes, respectively. Meta-regression analyses were performed to assess whether estimates of treatment effects were associated with methodological characteristics of trials. Thirty trials, including 4102 patients, were analysed. The overall risk of bias was judged to be low in only 43% of the trials. Ten trials (33%) demonstrated statistically significant superiority of invasive interventions over placebo controls for the respective predefined primary outcomes. In almost half of the 16 trials investigating continuous predefined primary outcomes, the SMD between the active and placebo procedure indicated a small (n = 4) to moderate (n = 3) treatment effect of active treatment over placebo. In contrast, one trial indicated a small treatment effect in favour of the placebo procedure. In the remaining trials, there was no relevant treatment effect of active treatment over placebo. In trials with a protocol-mandated stable and symmetrical use of co-interventions, the superiority of active procedures vs. invasive placebo procedures was significantly larger as compared with trials with frequent or unbalanced changes in co-interventions (P for interaction 0.027). CONCLUSIONS: The additional treatment effect of invasive cardiovascular interventions compared with placebo controls was small in most trials.


Asunto(s)
Ensayos Clínicos Controlados Aleatorios como Asunto , Humanos
13.
Circulation ; 140(2): 147-163, 2019 07 09.
Artículo en Inglés | MEDLINE | ID: mdl-31146585

RESUMEN

BACKGROUND: The cells that form the arterial wall contribute to multiple vascular diseases. The extent of cellular heterogeneity within these populations has not been fully characterized. Recent advances in single-cell RNA-sequencing make it possible to identify and characterize cellular subpopulations. METHODS: We validate a method for generating a droplet-based single-cell atlas of gene expression in a normal blood vessel. Enzymatic dissociation of 4 whole mouse aortas was followed by single-cell sequencing of >10 000 cells. RESULTS: Clustering analysis of gene expression from aortic cells identified 10 populations of cells representing each of the main arterial cell types: fibroblasts, vascular smooth muscle cells, endothelial cells (ECs), and immune cells, including monocytes, macrophages, and lymphocytes. The most significant cellular heterogeneity was seen in the 3 distinct EC populations. Gene set enrichment analysis of these EC subpopulations identified a lymphatic EC cluster and 2 other populations more specialized in lipoprotein handling, angiogenesis, and extracellular matrix production. These subpopulations persist and exhibit similar changes in gene expression in response to a Western diet. Immunofluorescence for Vcam1 and Cd36 demonstrates regional heterogeneity in EC populations throughout the aorta. CONCLUSIONS: We present a comprehensive single-cell atlas of all cells in the aorta. By integrating expression from >1900 genes per cell, we are better able to characterize cellular heterogeneity compared with conventional approaches. Gene expression signatures identify cell subpopulations with vascular disease-relevant functions.


Asunto(s)
Aorta/citología , Aorta/fisiología , Células Endoteliales/fisiología , Perfilación de la Expresión Génica/métodos , Análisis de la Célula Individual/métodos , Animales , Femenino , Ratones , Ratones Endogámicos C57BL
14.
Crit Care ; 24(1): 95, 2020 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-32188462

RESUMEN

BACKGROUND: Concomitant vasoactive drugs are often required to maintain adequate perfusion pressure in patients with acute myocardial infarction (AMI) and cardiogenic shock (CS) receiving hemodynamic support with an axial flow pump (Impella CP). OBJECTIVE: To compare the effect of equipotent dosages of epinephrine, dopamine, norepinephrine, and phenylephrine on cardiac work and end-organ perfusion in a porcine model of profound ischemic CS supported with an Impella CP. METHODS: CS was induced in 10 pigs by stepwise intracoronary injection of polyvinyl microspheres. Hemodynamic support with Impella CP was initiated followed by blinded crossover to vasoactive treatment with norepinephrine (0.10 µg/kg/min), epinephrine (0.10 µg/kg/min), or dopamine (10 µg/kg/min) for 30 min each. At the end of the study, phenylephrine (10 µg/kg/min) was administered for 20 min. The primary outcome was cardiac workload, a product of pressure-volume area (PVA) and heart rate (HR), measured using the conductance catheter technique. End-organ perfusion was assessed by measuring venous oxygen saturation from the pulmonary artery (SvO2), jugular bulb, and renal vein. Treatment effects were evaluated using multilevel mixed-effects linear regression. RESULTS: All catecholamines significantly increased LV stroke work and cardiac work, dopamine to the greatest extend by 341.8 × 103 (mmHg × mL)/min [95% CI (174.1, 509.5), p < 0.0001], and SvO2 significantly improved during all catecholamines. Phenylephrine, a vasoconstrictor, caused a significant increase in cardiac work by 437.8 × 103 (mmHg × mL)/min [95% CI (297.9, 577.6), p < 0.0001] due to increase in potential energy (p = 0.001), but no significant change in LV stroke work. Also, phenylephrine tended to decrease SvO2 (p = 0.063) and increased arterial lactate levels (p = 0.002). CONCLUSION: Catecholamines increased end-organ perfusion at the expense of increased cardiac work, most by dopamine. However, phenylephrine increased cardiac work with no increase in end-organ perfusion.


Asunto(s)
Gasto Cardíaco/efectos de los fármacos , Corazón Auxiliar , Hemodinámica/efectos de los fármacos , Choque Cardiogénico/terapia , Animales , Catecolaminas/uso terapéutico , Modelos Animales de Enfermedad , Dopamina , Humanos , Infarto del Miocardio/complicaciones , Infarto del Miocardio/terapia , Norepinefrina , Fenilefrina , Choque Cardiogénico/fisiopatología , Porcinos
15.
Biomed Instrum Technol ; 54(1): 37-43, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31961742

RESUMEN

Hydrophilic polymer coatings on intravascular devices lower friction between the device and vasculature, thereby reducing trauma during interventional procedures. Polymer coating embolism-the detachment and downstream embolism of polymer particles-has been reported as an iatrogenic complication of coated interventional devices affecting the vasculature and various organs. The Food and Drug Administration (FDA) acknowledges this complication and continues to work with stakeholders to close gaps in performance testing and standards related to polymer coating integrity. Recent innovations within interventional technologies have led to development of new hydrophilic-coated devices with expanded indications for use. The 2018 FDA draft guidance for intravascular guidewires expands the application of particulate generation testing to most devices and recommends labeling changes to increase industry awareness. This article highlights current procedural trends where the phenomenon of polymer coating embolism may be more prevalent. It describes the mechanisms of polymer separation, reported clinical sequelae, and risk factors for relevant indications. These procedural trends and associated risk factors articulate the need for particulate testing and support the FDA's draft guidance recommendations for performance testing of applied coatings. If standardized, particulate assessments may allow characterization and comparisons of coating integrity among devices from various manufacturers, and are an important foundation for setting particulate limits. As hydrophilic coatings enable endovascular treatment for a range of patient populations, setting particulate limits or finding alternative solutions without compromise to device function may be essential. Particulate testing is relevant to physicians, regulators, and manufacturers for the purposes of product development and quality improvement of interventional devices.


Asunto(s)
Embolia , Materiales Biocompatibles Revestidos , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Polímeros , Estados Unidos , United States Food and Drug Administration
16.
Am J Physiol Cell Physiol ; 316(2): C210-C222, 2019 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-30566394

RESUMEN

The programmed form of cell death (apoptosis) is essential for normal development of multicellular organisms. Dysregulation of apoptosis has been linked with embryonal death and is involved in the pathophysiology of various diseases. Specifically, endothelial apoptosis plays pivotal roles in atherosclerosis whereas prevention of endothelial apoptosis is a prerequisite for neovascularization in tumors and metastasis. Endothelial biology is intertwined with the composition of subendothelial basement membrane proteins. Apoptosis was induced by addition of tumor necrosis factor-α to cycloheximide-sensitized endothelial cells. Cells were either grown on polystyrene culture plates or on plates precoated with healthy basement membrane proteins (collagen IV, fibronectin, or laminin) or collagen I. Our results reveal that proteins of healthy basement membrane alleviate cytokine-induced apoptosis whereas precoating with collagen type I had no significant effect on apoptosis by addition of tumor necrosis factor-α to cycloheximide-sensitized endothelial cells compared with cells cultured on uncoated plates. Yet, treatment with transforming growth factor-ß1 significantly reduced the rate of apoptosis endothelial cells grown on collagen I. Detailed analysis reveals differences in intracellular signaling pathways for each of the basement membrane proteins studied. We provide additional insights into the importance of basement membrane proteins and the respective cytokine milieu on endothelial biology. Exploring outside-in signaling by basement membrane proteins may constitute an interesting target to restore vascular function and prevent complications in the atherosclerotic cascade.


Asunto(s)
Aorta/metabolismo , Apoptosis/fisiología , Membrana Basal/metabolismo , Vasos Coronarios/metabolismo , Células Endoteliales/metabolismo , Aorta/citología , Membrana Basal/citología , Células Cultivadas , Vasos Coronarios/citología , Matriz Extracelular/metabolismo , Humanos
17.
Catheter Cardiovasc Interv ; 93(2): 278-285, 2019 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-30244502

RESUMEN

OBJECTIVES: Drug-eluting stent (DES) strut fracture (SF) is associated with higher incidence of In-stent restenosis (ISR)-return of blockage in a diseased artery post stenting-than seen with bare metal stents (BMS). We hypothesize that concomitance of drug and SF leads to greater neointimal response. BACKGROUND: Controlled release of therapeutic agents, such as sirolimus and its analogs, or paclitaxel from has reduced tissue based DES failure modes compared to BMS. ISR is dramatically reduced and yet the implications of mechanical device failure is magnified. METHODS: Bilateral Xience Everolimus-eluting stents (EES) were implanted in 20 New Zealand White rabbits on normal (n = 7) or high fat (HF)/high cholesterol (HC) (n = 13) diets. Implanted stents were intact or mechanically fractured. Everolimus concentration was as packaged or pre-eluted. After 21 days, stented vessels were explanted, resin embedded, MicroCT scanned, and analyzed histomorphometrically. RESULTS: Fractured EES were associated with significant (P < 0.05) increases in arterial stenosis and neointimal formation and lower lumen-to-artery area ratios compared to intact EES. Hyperlipidemic animals receiving pre-eluted EES revealed no significant difference between intact and fracture groups. CONCLUSIONS: SF increases intimal hyperplasia, post EES implant, and worse with more advanced disease. Pre-eluted groups, reflective of BMS, did not show significant differences, suggesting a synergistic effect of everolimus and mechanical injury, potentially explaining the lack of SF reports for BMS. Here, we report that ISR has a higher incidence with SF in EES, the clinical implication is that patients with SF after DES implantation merit careful follow-up.


Asunto(s)
Aterosclerosis/terapia , Fármacos Cardiovasculares/administración & dosificación , Stents Liberadores de Fármacos , Procedimientos Endovasculares/instrumentación , Everolimus/administración & dosificación , Arteria Ilíaca/patología , Neointima , Falla de Prótesis , Animales , Aterosclerosis/diagnóstico por imagen , Aterosclerosis/etiología , Aterosclerosis/patología , Colesterol en la Dieta , Dieta Alta en Grasa , Modelos Animales de Enfermedad , Procedimientos Endovasculares/efectos adversos , Hiperplasia , Arteria Ilíaca/diagnóstico por imagen , Diseño de Prótesis , Conejos , Factores de Tiempo
18.
Nano Lett ; 18(9): 5839-5845, 2018 09 12.
Artículo en Inglés | MEDLINE | ID: mdl-30096241

RESUMEN

Fibrosis contributes to ∼45% of all deaths in industrialized nations, but no direct antifibrotic therapeutic interventions exist to date. Graphene-based nanomaterials exhibit excellent versatility in electronics, and emerging trends exploit their properties for biomedical applications, especially for drug and gene delivery. We designed constructs of graphene nanostars linked to PAMAM-G5 dendrimer for the selective targeting and delivery of a plasmid expressing the collagenase metalloproteinase 9 under the CD11b promoter into inflammatory macrophages in cirrhotic livers. Graphene nanostars preferentially accumulated in inflammatory macrophages M1 in less than 3 h in a manner unaffected by covalent linkage to dendrimers. Dendrimer-graphene nanostars efficiently delivered the plasmid encoding for metalloproteinase 9 into macrophages, allowing the synthesis and secretion of the metalloproteinase to digest adjacent collagen fibers. In turn, metalloproteinase 9 overexpression promoted the macrophage switch from inflammatory M1 to pro-regenerative M2 in 3 days. This targeted gene therapy reduced selectively and locally the presence of collagen fibers in fibrotic tracts where inflammatory macrophages accumulated in cirrhotic mice without affecting the activation state of hepatic stellate cells. Overall, this treatment significantly reduced hepatic injury and improved liver restoration in mice with liver cirrhosis treated for 10 days. Graphene-dendrimer nanostars targeted the macrophage overexpression of metalloproteinase 9, selectively reducing hepatic fibrosis, and might be a good treatment for diseases associated with fibrosis and inflammatory macrophage accumulation.


Asunto(s)
Dendrímeros/química , Grafito/química , Cirrosis Hepática/terapia , Macrófagos/metabolismo , Metaloproteinasa 9 de la Matriz/genética , Nanopartículas/química , Plásmidos/administración & dosificación , Animales , Técnicas de Transferencia de Gen , Terapia Genética , Cirrosis Hepática/genética , Ratones , Ratones Endogámicos BALB C , Nanopartículas/ultraestructura , Plásmidos/genética , Plásmidos/uso terapéutico , Regulación hacia Arriba
19.
Circulation ; 136(14): 1304-1314, 2017 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-28794001

RESUMEN

BACKGROUND: The safety and efficacy of a novel cobalt alloy-based coronary stent with a durable elastomeric polymer eluting the antiproliferative agent ridaforolimus for treatment of patients with coronary artery disease is undetermined. METHODS: A prospective, international 1:1 randomized trial was conducted to evaluate in a noninferiority design the relative safety and efficacy of ridaforolimus-eluting stents (RESs) and slow-release zotarolimus-eluting stents among 1919 patients undergoing percutaneous coronary intervention at 76 centers. Inclusion criteria allowed enrollment of patients with recent myocardial infarction, total occlusions, bifurcations lesions, and other complex conditions. RESULTS: Baseline clinical and angiographic characteristics were similar between the groups. Overall, mean age was 63.4 years, 32.5% had diabetes mellitus, and 39.7% presented with acute coronary syndromes. At 12 months, the primary end point of target lesion failure (composite of cardiac death, target vessel-related myocardial infarction, and target lesion revascularization) was 5.4% for both devices (upper bound of 1-sided 95% confidence interval 1.8%, Pnoninferiority=0.001). Definite/probable stent thrombosis rates were low in both groups (0.4% RES versus 0.6% zotarolimus-eluting stent, P=0.75); 13-month angiographic in-stent late lumen loss was 0.22±0.41 mm and 0.23±0.39 mm (Pnoninferiority=0.004) for the RES and zotarolimus-eluting stent groups, respectively, and intravascular ultrasound percent neointimal hyperplasia was 8.10±5.81 and 8.85±7.77, respectively (Pnoninferiority=0.01). CONCLUSIONS: In the present trial, which allowed broad inclusion criteria, the novel RESs met the prespecified criteria for noninferiority compared with zotarolimus-eluting stents for the primary end point of target lesion failure at 12 months and had similar measures of late lumen loss. These findings support the safety and efficacy of RESs in patients who are representative of clinical practice. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01995487.


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos/normas , Intervención Coronaria Percutánea/métodos , Sirolimus/análogos & derivados , Femenino , Humanos , Masculino , Estudios Prospectivos , Sirolimus/administración & dosificación , Sirolimus/farmacología , Sirolimus/uso terapéutico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA