1.
J Arthroplasty ; 23(8): 1122-7, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18534421

RESUMEN

This preliminary prospective study to determine the rate of deep venous thrombosis (DVT) examined 277 patients undergoing total knee or total hip arthroplasty (TKA or THA) who were randomized to use a portable, continuous enhanced circulation therapy (CECT) compression device and low-molecular-weight heparin (LMWH) or to receive LMWH alone. Patients were screened for DVT using duplex ultrasound at hospital discharge and followed clinically for 3 months. In TKA, 5 DVTs (6.6%) occurred in the CECT + LMWH group compared with one pulmonary embolism and 14 DVTs (19.5%) in the LMWH group (P = .018). In THA, 1 DVT (1.5%) occurred in the CECT + LMWH group and 2 DVTs (3.4%) occurred in the LMWH group. This preliminary study demonstrated significant reduction in rate of DVT after TKA when the CECT device was combined with LMWH.


Asunto(s)
Anticoagulantes/uso terapéutico , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Heparina de Bajo-Peso-Molecular/uso terapéutico , Aparatos de Compresión Neumática Intermitente , Trombosis de la Vena/etiología , Trombosis de la Vena/prevención & control , Adulto , Anciano , Anciano de 80 o más Años , Terapia Combinada , Femenino , Estudios de Seguimiento , Humanos , Masculino , Tamizaje Masivo , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento , Ultrasonografía , Trombosis de la Vena/diagnóstico por imagen
4.
J Arthroplasty ; 19(3): 369-72, 2004 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15067653

RESUMEN

Flexion following total knee arthroplasty can be visually estimated, measured with a goniometer placed against the patient's leg, or measured from a lateral radiograph of the flexed knee. Three examiners, in a blinded fashion, estimated the degree of maximal knee flexion and measured the flexion with a goniometer for 27 knees in 16 patients. A lateral knee radiograph then was taken and the flexion angle was measured from the radiograph by 2 different methods. Although interobserver and intraobserver correlation coefficients were high (0.79 and 0.92), 45% of the visual estimates and 22% of the goniometer measurements differed by 5 degrees or greater from the radiographic measurements. These differences increased as the flexion angle increased. Body mass index did not affect the accuracy of the estimates or goniometer measurements.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Articulación de la Rodilla/fisiopatología , Prótesis de la Rodilla , Femenino , Fémur/diagnóstico por imagen , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Masculino , Radiografía , Tibia/diagnóstico por imagen