Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 328
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Gastroenterology ; 165(6): 1533-1546.e4, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37657758

RESUMEN

BACKGROUND & AIMS: The aims of our case-control study were (1) to develop an automated 3-dimensional (3D) Convolutional Neural Network (CNN) for detection of pancreatic ductal adenocarcinoma (PDA) on diagnostic computed tomography scans (CTs), (2) evaluate its generalizability on multi-institutional public data sets, (3) its utility as a potential screening tool using a simulated cohort with high pretest probability, and (4) its ability to detect visually occult preinvasive cancer on prediagnostic CTs. METHODS: A 3D-CNN classification system was trained using algorithmically generated bounding boxes and pancreatic masks on a curated data set of 696 portal phase diagnostic CTs with PDA and 1080 control images with a nonneoplastic pancreas. The model was evaluated on (1) an intramural hold-out test subset (409 CTs with PDA, 829 controls); (2) a simulated cohort with a case-control distribution that matched the risk of PDA in glycemically defined new-onset diabetes, and Enriching New-Onset Diabetes for Pancreatic Cancer score ≥3; (3) multi-institutional public data sets (194 CTs with PDA, 80 controls), and (4) a cohort of 100 prediagnostic CTs (i.e., CTs incidentally acquired 3-36 months before clinical diagnosis of PDA) without a focal mass, and 134 controls. RESULTS: Of the CTs in the intramural test subset, 798 (64%) were from other hospitals. The model correctly classified 360 CTs (88%) with PDA and 783 control CTs (94%), with a mean accuracy 0.92 (95% CI, 0.91-0.94), area under the receiver operating characteristic (AUROC) curve of 0.97 (95% CI, 0.96-0.98), sensitivity of 0.88 (95% CI, 0.85-0.91), and specificity of 0.95 (95% CI, 0.93-0.96). Activation areas on heat maps overlapped with the tumor in 350 of 360 CTs (97%). Performance was high across tumor stages (sensitivity of 0.80, 0.87, 0.95, and 1.0 on T1 through T4 stages, respectively), comparable for hypodense vs isodense tumors (sensitivity: 0.90 vs 0.82), different age, sex, CT slice thicknesses, and vendors (all P > .05), and generalizable on both the simulated cohort (accuracy, 0.95 [95% 0.94-0.95]; AUROC curve, 0.97 [95% CI, 0.94-0.99]) and public data sets (accuracy, 0.86 [95% CI, 0.82-0.90]; AUROC curve, 0.90 [95% CI, 0.86-0.95]). Despite being exclusively trained on diagnostic CTs with larger tumors, the model could detect occult PDA on prediagnostic CTs (accuracy, 0.84 [95% CI, 0.79-0.88]; AUROC curve, 0.91 [95% CI, 0.86-0.94]; sensitivity, 0.75 [95% CI, 0.67-0.84]; and specificity, 0.90 [95% CI, 0.85-0.95]) at a median 475 days (range, 93-1082 days) before clinical diagnosis. CONCLUSIONS: This automated artificial intelligence model trained on a large and diverse data set shows high accuracy and generalizable performance for detection of PDA on diagnostic CTs as well as for visually occult PDA on prediagnostic CTs. Prospective validation with blood-based biomarkers is warranted to assess the potential for early detection of sporadic PDA in high-risk individuals.


Asunto(s)
Carcinoma Ductal Pancreático , Diabetes Mellitus , Neoplasias Pancreáticas , Humanos , Inteligencia Artificial , Estudios de Casos y Controles , Detección Precoz del Cáncer , Neoplasias Pancreáticas/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Carcinoma Ductal Pancreático/diagnóstico por imagen , Estudios Retrospectivos
2.
Radiology ; 310(3): e231986, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38501953

RESUMEN

Photon-counting CT (PCCT) is an emerging advanced CT technology that differs from conventional CT in its ability to directly convert incident x-ray photon energies into electrical signals. The detector design also permits substantial improvements in spatial resolution and radiation dose efficiency and allows for concurrent high-pitch and high-temporal-resolution multienergy imaging. This review summarizes (a) key differences in PCCT image acquisition and image reconstruction compared with conventional CT; (b) early evidence for the clinical benefit of PCCT for high-spatial-resolution diagnostic tasks in thoracic imaging, such as assessment of airway and parenchymal diseases, as well as benefits of high-pitch and multienergy scanning; (c) anticipated radiation dose reduction, depending on the diagnostic task, and increased utility for routine low-dose thoracic CT imaging; (d) adaptations for thoracic imaging in children; (e) potential for further quantitation of thoracic diseases; and (f) limitations and trade-offs. Moreover, important points for conducting and interpreting clinical studies examining the benefit of PCCT relative to conventional CT and integration of PCCT systems into multivendor, multispecialty radiology practices are discussed.


Asunto(s)
Radiología , Tomografía Computarizada por Rayos X , Niño , Humanos , Procesamiento de Imagen Asistido por Computador , Fotones
3.
Radiology ; 312(2): e233038, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39105638

RESUMEN

Background Standardized methods to measure and describe Crohn disease strictures at CT enterography are needed to guide clinical decision making and for use in therapeutic studies. Purpose To assess the reliability of CT enterography features to describe Crohn disease strictures and their correlation with stricture severity. Materials and Methods A retrospective study was conducted in 43 adult patients with symptomatic terminal ileal Crohn disease strictures who underwent standard-of-care CT enterography at a tertiary care center at the Cleveland Clinic between January 2008 and August 2016. After training on standardized definitions, four abdominal radiologists blinded to all patient information assessed imaging features (seven continuous measurements and nine observations) of the most distal ileal stricture in two separate sessions (separated by ≥2 weeks) in random order. Features with an interrater intraclass correlation coefficient (ICC) of 0.41 or greater (ie, moderate reliability or better) were considered reliable. Univariable and multivariable linear regression analysis identified reliable features associated with a visual analog scale of overall stricture severity. Significant reliable features were assessed as components of a CT enterography-based model to quantitate stricture severity. Results Examinations in 43 patients (mean age, 52 years ± 16 [SD]; 23 female) were evaluated. Five continuous measurements and six observations demonstrated at least moderate interrater reliability (interrater ICC range, 0.42 [95% CI: 0.25, 0.57] to 0.80 [95% CI: 0.67, 0.88]). Of these, 10 were univariably associated with stricture severity, and three continuous measurements-stricture length (interrater ICC, 0.64 [95% CI: 0.42, 0.81]), maximal associated small bowel dilation (interrater ICC, 0.80 [95% CI: 0.67, 0.88]), and maximal stricture wall thickness (interrater ICC, 0.50 [95% CI: 0.34, 0.62])-were independently associated (P value range, <.001 to .003) with stricture severity in a multivariable model. These three measurements were used to derive a well-calibrated (optimism-adjusted calibration slope = 1.00) quantitative model of stricture severity. Conclusion Standardized CT enterography measurements and observations can reliably describe terminal ileal Crohn disease strictures. Stricture length, maximal associated small bowel dilation, and maximal stricture wall thickness are correlated with stricture severity. © RSNA, 2024 Supplemental material is available for this article. See also the article by Rieder et al in this issue. See also the editorial by Galgano and Summerlin in this issue.


Asunto(s)
Enfermedad de Crohn , Tomografía Computarizada por Rayos X , Humanos , Enfermedad de Crohn/diagnóstico por imagen , Femenino , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Reproducibilidad de los Resultados , Constricción Patológica/diagnóstico por imagen , Adulto , Anciano
4.
Radiology ; 312(2): e233039, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39105637

RESUMEN

Background Clinical decision making and drug development for fibrostenosing Crohn disease is constrained by a lack of imaging definitions, scoring conventions, and validated end points. Purpose To assess the reliability of MR enterography features to describe Crohn disease strictures and determine correlation with stricture severity. Materials and Methods A retrospective study of patients with symptomatic terminal ileal Crohn disease strictures who underwent MR enterography at tertiary care centers (Cleveland Clinic: September 2013 to November 2020; Mayo Clinic: February 2008 to March 2019) was conducted by using convenience sampling. In the development phase, blinded and trained radiologists independently evaluated 26 MR enterography features from baseline and follow-up examinations performed more than 6 months apart, with no bowel resection performed between examinations. Follow-up examinations closest to 12 months after baseline were selected. Reliability was assessed using the intraclass correlation coefficient (ICC). In the validation phase, after five features were redefined, reliability was re-estimated in an independent convenience sample using baseline examinations. Multivariable linear regression analysis identified features with at least moderate interrater reliability (ICC ≥0.41) that were independently associated with stricture severity. Results Ninety-nine (mean age, 40 years ± 14 [SD]; 50 male) patients were included in the development group and 51 (mean age, 45 years ± 16 [SD]; 35 female) patients were included in the validation group. In the development group, nine features had at least moderate interrater reliability. One additional feature demonstrated moderate reliability in the validation group. Stricture length (ICC = 0.85 [95% CI: 0.75, 0.91] and 0.91 [95% CI: 0.75, 0.96] in development and validation phase, respectively) and maximal associated small bowel dilation (ICC = 0.74 [95% CI: 0.63, 0.80] and 0.73 [95% CI: 0.58, 0.87] in development and validation group, respectively) had the highest interrater reliability. Stricture length, maximal stricture wall thickness, and maximal associated small bowel dilation were independently (regression coefficients, 0.09-3.97; P < .001) associated with stricture severity. Conclusion MR enterography definitions and scoring conventions for reliably assessing features of Crohn disease strictures were developed and validated, and feature correlation with stricture severity was determined. © RSNA, 2024 Supplemental material is available for this article. See also the article by Rieder and Ma et al in this issue. See also the editorial by Galgano and Summerlin in this issue.


Asunto(s)
Enfermedad de Crohn , Imagen por Resonancia Magnética , Humanos , Enfermedad de Crohn/diagnóstico por imagen , Femenino , Masculino , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos , Adulto , Reproducibilidad de los Resultados , Constricción Patológica/diagnóstico por imagen , Persona de Mediana Edad
5.
AJR Am J Roentgenol ; 222(3): e2329778, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37991334

RESUMEN

BACKGROUND. The higher spatial resolution and image contrast for iodine-containing tissues of photon-counting detector (PCD) CT may address challenges in evaluating small calcified vessels when performing lower extremity CTA by energy-integrating detector (EID) CTA. OBJECTIVE. The purpose of the study was to compare the evaluation of infrapopliteal vasculature between lower extremity CTA performed using EID CT and PCD CT. METHODS. This prospective study included 32 patients (mean age, 69.7 ± 11.3 [SD] years; 27 men, five women) who underwent clinically indicated lower extremity EID CTA between April 2021 and March 2022; participants underwent investigational lower extremity PCD CTA later the same day as EID CTA using a reduced IV contrast media dose. Two radiologists independently reviewed examinations in two sessions, each containing a random combination of EID CTA and PCD CTA examinations; the readers assessed the number of visualized fibular perforators, characteristics of stenoses at 11 infrapopliteal segmental levels, and subjective arterial sharpness. RESULTS. Mean IV contrast media dose was 60.0 ± 11.0 (SD) mL for PCD CTA versus 139.6 ± 11.8 mL for EID CTA (p < .001). The number of identified fibular perforators per lower extremity was significantly higher for PCD CTA than for EID CTA for reader 1 (R1) (mean ± SD, 6.4 ± 3.2 vs 4.2 ± 2.4; p < .001) and reader 2 (R2) (8.8 ± 3.4 vs 7.6 ± 3.3; p = .04). Reader confidence for assessing stenosis was significantly higher for PCD CTA than for EID CTA for R1 (mean ± SD, 82.3 ± 20.3 vs 78.0 ± 20.2; p < .001) but not R2 (89.8 ± 16.7 vs 90.6 ± 7.1; p = .24). The number of segments per lower extremity with total occlusion was significantly lower for PCD CTA than for EID CTA for R2 (mean ± SD, 0.5 ± 1.3 vs 0.9 ± 1.7; p = .04) but not R1 (0.6 ± 1.3 vs 1.0 ± 1.5; p = .07). The number of segments per lower extremity with clinically significant nonocclusive stenosis was significantly higher for PCD CTA than for EID CTA for R1 (mean ± SD, 2.2 ± 2.2 vs 1.6 ± 1.7; p = .01) but not R2 (1.1 ± 2.0 vs 1.1 ± 1.4; p = .89). Arterial sharpness was significantly greater for PCD CTA than for EID CTA for R1 (mean ± SD, 3.2 ± 0.5 vs 1.8 ± 0.5; p < .001) and R2 (3.2 ± 0.4 vs 1.7 ± 0.8; p < .001). CONCLUSION. PCD CTA yielded multiple advantages relative to EID CTA for visualizing small infrapopliteal vessels and characterizing associated plaque. CLINICAL IMPACT. The use of PCD CTA may improve vascular evaluation in patients with peripheral arterial disease.


Asunto(s)
Medios de Contraste , Fotones , Masculino , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Estudios Prospectivos , Constricción Patológica , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Extremidad Inferior/diagnóstico por imagen
6.
Artículo en Inglés | MEDLINE | ID: mdl-39146219

RESUMEN

OBJECTIVE: Pulmonary CT angiography (CTA) to detect pulmonary emboli can be performed using conventional dual-source CT with single-energy acquisition at high-pitch (high-pitch conventional CT), which minimizes motion artifacts, or routine-pitch, dual-energy acquisitions (routine-pitch conventional DECT), which maximize iodine signal. We compared iodine signal, radiation dose, and motion artifacts of pulmonary CTA between these conventional CT modalities and dual-source photon-counting detector CT with high-pitch, multienergy acquisitions (high-pitch photon-counting CT). METHODS: Consecutive clinically indicated pulmonary CTA exams were collected. CT number/noise was measured from the main to right lower lobe segmental pulmonary arteries using 120 kV threshold low, 120 kV, and mixed kV (0.6 linear blend) images. Three radiologists reviewed anonymized, randomized exams, rating them using a 4- or 5-point Likert scale (1 = worst, and 4/5 = best) for contrast enhancement in pulmonary arteries, motion artifacts in aortic root to subsegmental pulmonary arteries, lung image quality; pulmonary blood volume (PBV) map image quality (for multienergy or dual-energy exams), and contribution to reader confidence. RESULTS: One hundred fifty patients underwent high-pitch photon-counting CT (n = 50), high-pitch conventional CT (n = 50), and routine-pitch conventional DECT (n = 50). High-pitch photon-counting CT had lower radiation dose (CTDIvol: 8.1 ± 2.5 vs 9.6 ± 6.8 and 16.2 ± 8.5 mGy, respectively; P < 0.001), and routine-pitch conventional DECT had significantly less contrast (P < 0.009). CT number and CNR measurements were significantly greater at high-pitch photon-counting CT (P < 0.001). Across readers, high-pitch photon-counting CT demonstrated significantly higher subjective contrast enhancement in the pulmonary arteries compared to the other modalities (4.7 ± 0.6 vs 4.4 ± 0.7 vs 4.3 ± 0.7; P = 0.011) and lung image quality (3.4 ± 0.5 vs 3.1 ± 0.5 vs 3.1 ± 0.5; P = 0.013). High-pitch photon-counting CT and high-pitch conventional CT had fewer motion artifacts at all levels compared to DECT (P < 0.001). High-pitch photon-counting CT PBV maps had superior image quality (P < 0.001) and contribution to reader confidence (P < 0.001) compared to routine-pitch conventional DECT. CONCLUSION: High-pitch photon-counting pulmonary CTA demonstrated higher contrast in pulmonary arteries at lower radiation doses with improved lung image quality and fewer motion artifacts compared to high-pitch conventional CT and routine-pitch conventional dual-energy CT.

7.
Skeletal Radiol ; 2024 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-39120685

RESUMEN

OBJECTIVE: To determine the accuracy of photon-counting-detector CT (PCD-CT) at deriving bone morphometric indices and demonstrate utility in vivo in the distal radius. METHODS: Ten cadaver wrists were scanned using PCD-CT and high-resolution peripheral quantitative CT (HRpQCT). Correlation between PCD-CT and HRpQCT morphometric indices was determined. Agreement was assessed by Lin's concordance correlation coefficient (Lin's CCC). Wrist PCD-CTs of patients between 02/2022 and 08/2023 were also evaluated for clinical utility. Morphometric indices of the in vivo distal radii were extracted and compared between patients with or without osteoporosis. RESULTS: In cadavers, strong correlation between PCD-CT and HRpQCT was observed for cortical thickness (Spearman correlation, ρ, 0.85), trabecular spacing (ρ = 0.98), and trabecular bone volume fraction (ρ = 0.68). Moderate negative correlation (ρ = - 0.49) was observed for trabecular thickness. PCD-CT shows good agreement to HRpQCT for cortical thickness, trabecular spacing, and trabecular bone volume fraction (Lin's CCC = 0.80, 0.94, and 0.86, respectively) but poor agreement (Lin's CCC = - 0.1) for trabecular thickness. In forty participants (31 adults and 9 pediatric), bone morphometrics indices for cortical thickness, trabecular thickness, trabecular spacing, and trabecular bone volume fraction were 0.99 mm (IQR, 0.89-1.06), 0.38 mm (IQR, 0.25-0.40), 0.82 mm (IQR, 0.72-1.05), and 0.28 (IQR, 0.25-0.33), respectively. Patients with osteoporosis had statistically significantly larger trabecular spacing (p = 0.025) and lower trabecular volumetric bone mineral density (p = 0.042). CONCLUSION: This study demonstrates the agreement of PCD-CT to HRpQCT in cadavers of most cortical and bone morphometrics examined and provide in vivo quantitative metrics of bone microarchitecture from routine clinical PCD-CT images of the distal radius.

8.
Gastroenterology ; 162(4): 1111-1122.e2, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34951994

RESUMEN

BACKGROUND & AIMS: Diagnostic tests for defecatory disorders (DDs) asynchronously measure anorectal pressures and evacuation and show limited agreement; thus, abdominopelvic-rectoanal coordination in normal defecation and DDs is poorly characterized. We aimed to investigate anorectal pressures, anorectal and abdominal motion, and evacuation simultaneously in healthy and constipated women. METHODS: Abdominal wall and anorectal motion, anorectal pressures, and rectal evacuation were measured simultaneously with supine magnetic resonance defecography and anorectal manometry. Evacuators were defined as those who attained at least 25% rectal evacuation. Supervised (logistic regression and random forest algorithm) and unsupervised (k-means cluster) analyses identified abdominal and anorectal variables that predicted evacuation. RESULTS: We evaluated 28 healthy and 26 constipated women (evacuators comprised 19 healthy participants and 8 patients). Defecation was initiated by abdominal wall expansion that was coordinated with anorectal descent, increased rectal and anal pressure, and then anal relaxation and rectal evacuation. Compared with evacuators, nonevacuators had lower anal diameters during simulated defecation, rectal pressure, anorectal junction descent, and abdominopelvic-rectoanal coordination (P < .05). Unsupervised cluster analysis identified 3 clusters that were associated with evacuator status (P < .01), that is, 10 evacuators (83%), 16 evacuators (73%), and 1 evacuator (5%) in clusters 1, 2, and 3, respectively. Each cluster had distinct characteristics (eg, maximum abdominosacral distance, rectal pressure, anorectal junction descent, anal diameter) and correlates that were more (clusters 1-2) or less (cluster 3) conducive to evacuation. Cluster 2 had 16 evacuators (73%) and intermediate characteristics (eg, lower anal resting pressure and relaxation during evacuation; P < .05). CONCLUSIONS: Women with DDs and a modest proportion of healthy women had specific patterns of anorectal dysfunction, including inadequate rectal pressurization, anal relaxation, and abdominopelvic-rectoanal coordination. These observations may guide individualized therapy for DDs in the future.


Asunto(s)
Canal Anal , Recto , Estreñimiento/diagnóstico , Defecación , Femenino , Voluntarios Sanos , Humanos , Manometría , Recto/diagnóstico por imagen
9.
Gastroenterology ; 163(5): 1435-1446.e3, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35788343

RESUMEN

BACKGROUND & AIMS: Our purpose was to detect pancreatic ductal adenocarcinoma (PDAC) at the prediagnostic stage (3-36 months before clinical diagnosis) using radiomics-based machine-learning (ML) models, and to compare performance against radiologists in a case-control study. METHODS: Volumetric pancreas segmentation was performed on prediagnostic computed tomography scans (CTs) (median interval between CT and PDAC diagnosis: 398 days) of 155 patients and an age-matched cohort of 265 subjects with normal pancreas. A total of 88 first-order and gray-level radiomic features were extracted and 34 features were selected through the least absolute shrinkage and selection operator-based feature selection method. The dataset was randomly divided into training (292 CTs: 110 prediagnostic and 182 controls) and test subsets (128 CTs: 45 prediagnostic and 83 controls). Four ML classifiers, k-nearest neighbor (KNN), support vector machine (SVM), random forest (RM), and extreme gradient boosting (XGBoost), were evaluated. Specificity of model with highest accuracy was further validated on an independent internal dataset (n = 176) and the public National Institutes of Health dataset (n = 80). Two radiologists (R4 and R5) independently evaluated the pancreas on a 5-point diagnostic scale. RESULTS: Median (range) time between prediagnostic CTs of the test subset and PDAC diagnosis was 386 (97-1092) days. SVM had the highest sensitivity (mean; 95% confidence interval) (95.5; 85.5-100.0), specificity (90.3; 84.3-91.5), F1-score (89.5; 82.3-91.7), area under the curve (AUC) (0.98; 0.94-0.98), and accuracy (92.2%; 86.7-93.7) for classification of CTs into prediagnostic versus normal. All 3 other ML models, KNN, RF, and XGBoost, had comparable AUCs (0.95, 0.95, and 0.96, respectively). The high specificity of SVM was generalizable to both the independent internal (92.6%) and the National Institutes of Health dataset (96.2%). In contrast, interreader radiologist agreement was only fair (Cohen's kappa 0.3) and their mean AUC (0.66; 0.46-0.86) was lower than each of the 4 ML models (AUCs: 0.95-0.98) (P < .001). Radiologists also recorded false positive indirect findings of PDAC in control subjects (n = 83) (7% R4, 18% R5). CONCLUSIONS: Radiomics-based ML models can detect PDAC from normal pancreas when it is beyond human interrogation capability at a substantial lead time before clinical diagnosis. Prospective validation and integration of such models with complementary fluid-based biomarkers has the potential for PDAC detection at a stage when surgical cure is a possibility.


Asunto(s)
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Humanos , Estudios de Casos y Controles , Neoplasias Pancreáticas/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Carcinoma Ductal Pancreático/diagnóstico por imagen , Aprendizaje Automático , Estudios Retrospectivos , Neoplasias Pancreáticas
10.
Radiology ; 306(1): 229-236, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36066364

RESUMEN

Background Photon-counting detector (PCD) CT and deep learning noise reduction may improve spatial resolution at lower radiation doses compared with energy-integrating detector (EID) CT. Purpose To demonstrate the diagnostic impact of improved spatial resolution in whole-body low-dose CT scans for viewing multiple myeloma by using PCD CT with deep learning denoising compared with conventional EID CT. Materials and Methods Between April and July 2021, adult participants who underwent a whole-body EID CT scan were prospectively enrolled and scanned with a PCD CT system in ultra-high-resolution mode at matched radiation dose (8 mSv for an average adult) at an academic medical center. EID CT and PCD CT images were reconstructed with Br44 and Br64 kernels at 2-mm section thickness. PCD CT images were also reconstructed with Br44 and Br76 kernels at 0.6-mm section thickness. The thinner PCD CT images were denoised by using a convolutional neural network. Image quality was objectively quantified in two phantoms and a randomly selected subset of participants (10 participants; median age, 63.5 years; five men). Two radiologists scored PCD CT images relative to EID CT by using a five-point Likert scale to detect findings reflecting multiple myeloma. The scoring for the matched reconstruction series was blinded to scanner type. Reader-averaged scores were tested with the null hypothesis of equivalent visualization between EID and PCD. Results Twenty-seven participants (median age, 68 years; IQR, 61-72 years; 16 men) were included. The blinded assessment of 2-mm images demonstrated improvement in viewing lytic lesions, intramedullary lesions, fatty metamorphosis, and pathologic fractures for PCD CT versus EID CT (P < .05 for all comparisons). The 0.6-mm PCD CT images with convolutional neural network denoising also demonstrated improvement in viewing all four pathologic abnormalities and detected one or more lytic lesions in 21 of 27 participants compared with the 2-mm EID CT images (P < .001). Conclusion Ultra-high-resolution photon-counting detector CT improved the visibility of multiple myeloma lesions relative to energy-integrating detector CT. © RSNA, 2022 Online supplemental material is available for this article.


Asunto(s)
Aprendizaje Profundo , Mieloma Múltiple , Adulto , Anciano , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Fotones , Tomografía Computarizada por Rayos X/métodos , Femenino
11.
Radiology ; 306(2): e220266, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36194112

RESUMEN

Background Substantial interreader variability exists for common tasks in CT imaging, such as detection of hepatic metastases. This variability can undermine patient care by leading to misdiagnosis. Purpose To determine the impact of interreader variability associated with (a) reader experience, (b) image navigation patterns (eg, eye movements, workstation interactions), and (c) eye gaze time at missed liver metastases on contrast-enhanced abdominal CT images. Materials and Methods In a single-center prospective observational trial at an academic institution between December 2020 and February 2021, readers were recruited to examine 40 contrast-enhanced abdominal CT studies (eight normal, 32 containing 91 liver metastases). Readers circumscribed hepatic metastases and reported confidence. The workstation tracked image navigation and eye movements. Performance was quantified by using the area under the jackknife alternative free-response receiver operator characteristic (JAFROC-1) curve and per-metastasis sensitivity and was associated with reader experience and image navigation variables. Differences in area under JAFROC curve were assessed with the Kruskal-Wallis test followed by the Dunn test, and effects of image navigation were assessed by using the Wilcoxon signed-rank test. Results Twenty-five readers (median age, 38 years; IQR, 31-45 years; 19 men) were recruited and included nine subspecialized abdominal radiologists, five nonabdominal staff radiologists, and 11 senior residents or fellows. Reader experience explained differences in area under the JAFROC curve, with abdominal radiologists demonstrating greater area under the JAFROC curve (mean, 0.77; 95% CI: 0.75, 0.79) than trainees (mean, 0.71; 95% CI: 0.69, 0.73) (P = .02) or nonabdominal subspecialists (mean, 0.69; 95% CI: 0.60, 0.78) (P = .03). Sensitivity was similar within the reader experience groups (P = .96). Image navigation variables that were associated with higher sensitivity included longer interpretation time (P = .003) and greater use of coronal images (P < .001). The eye gaze time was at least 0.5 and 2.0 seconds for 71% (266 of 377) and 40% (149 of 377) of missed metastases, respectively. Conclusion Abdominal radiologists demonstrated better discrimination for the detection of liver metastases on abdominal contrast-enhanced CT images. Missed metastases frequently received at least a brief eye gaze. Higher sensitivity was associated with longer interpretation time and greater use of liver display windows and coronal images. © RSNA, 2022 Online supplemental material is available for this article.


Asunto(s)
Neoplasias Hepáticas , Masculino , Humanos , Adulto , Neoplasias Hepáticas/patología , Errores Diagnósticos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
12.
Eur Radiol ; 33(8): 5321-5330, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37014409

RESUMEN

Since 1971 and Hounsfield's first CT system, clinical CT systems have used scintillating energy-integrating detectors (EIDs) that use a two-step detection process. First, the X-ray energy is converted into visible light, and second, the visible light is converted to electronic signals. An alternative, one-step, direct X-ray conversion process using energy-resolving, photon-counting detectors (PCDs) has been studied in detail and early clinical benefits reported using investigational PCD-CT systems. Subsequently, the first clinical PCD-CT system was commercially introduced in 2021. Relative to EIDs, PCDs offer better spatial resolution, higher contrast-to-noise ratio, elimination of electronic noise, improved dose efficiency, and routine multi-energy imaging. In this review article, we provide a technical introduction to the use of PCDs for CT imaging and describe their benefits, limitations, and potential technical improvements. We discuss different implementations of PCD-CT ranging from small-animal systems to whole-body clinical scanners and summarize the imaging benefits of PCDs reported using preclinical and clinical systems. KEY POINTS: • Energy-resolving, photon-counting-detector CT is an important advance in CT technology. • Relative to current energy-integrating scintillating detectors, energy-resolving, photon-counting-detector CT offers improved spatial resolution, improved contrast-to-noise ratio, elimination of electronic noise, increased radiation and iodine dose efficiency, and simultaneous multi-energy imaging. • High-spatial-resolution, multi-energy imaging using energy-resolving, photon-counting-detector CT has been used in investigations into new imaging approaches, including multi-contrast imaging.


Asunto(s)
Yodo , Tomografía Computarizada por Rayos X , Animales , Tomografía Computarizada por Rayos X/métodos , Fotones , Rayos X , Fantasmas de Imagen
13.
Eur Radiol ; 33(8): 5309-5320, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37020069

RESUMEN

The X-ray detector is a fundamental component of a CT system that determines the image quality and dose efficiency. Until the approval of the first clinical photon-counting-detector (PCD) system in 2021, all clinical CT scanners used scintillating detectors, which do not capture information about individual photons in the two-step detection process. In contrast, PCDs use a one-step process whereby X-ray energy is converted directly into an electrical signal. This preserves information about individual photons such that the numbers of X-ray in different energy ranges can be counted. Primary advantages of PCDs include the absence of electronic noise, improved radiation dose efficiency, increased iodine signal and the ability to use lower doses of iodinated contrast material, and better spatial resolution. PCDs with more than one energy threshold can sort the detected photons into two or more energy bins, making energy-resolved information available for all acquisitions. This allows for material classification or quantitation tasks to be performed in conjunction with high spatial resolution, and in the case of dual-source CT, high pitch, or high temporal resolution acquisitions. Some of the most promising applications of PCD-CT involve imaging of anatomy where exquisite spatial resolution adds clinical value. These include imaging of the inner ear, bones, small blood vessels, heart, and lung. This review describes the clinical benefits observed to date and future directions for this technical advance in CT imaging. KEY POINTS: • Beneficial characteristics of photon-counting detectors include the absence of electronic noise, increased iodine signal-to-noise ratio, improved spatial resolution, and full-time multi-energy imaging. • Promising applications of PCD-CT involve imaging of anatomy where exquisite spatial resolution adds clinical value and applications requiring multi-energy data simultaneous with high spatial and/or temporal resolution. • Future applications of PCD-CT technology may include extremely high spatial resolution tasks, such as the detection of breast micro-calcifications, and quantitative imaging of native tissue types and novel contrast agents.


Asunto(s)
Compuestos de Yodo , Yodo , Humanos , Tomografía Computarizada por Rayos X/métodos , Tomógrafos Computarizados por Rayos X , Medios de Contraste , Fotones , Fantasmas de Imagen
14.
Dis Colon Rectum ; 66(2): 243-252, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36538706

RESUMEN

BACKGROUND: Refractory perianal Crohn's disease remains notoriously difficult to treat. We developed a novel technology using a commercially available bioabsorbable fistula plug to deliver autologous adipose-derived mesenchymal stem cells. OBJECTIVE: This study aimed to assess therapeutic safety and feasibility in the completed STOMP (stem cells on matrix plugs) phase 1 clinical trial. DESIGN: Prospective single-arm phase I clinical trial. SETTING: Tertiary academic medical center. PATIENTS: Adults (aged 18-65 y) with complex single-tract Crohn's disease perianal fistula who have failed conventional therapy were included in this study. INTERVENTION: Autologous adipose-derived mesenchymal stem cells were isolated, ex vivo culture expanded, and seeded onto a commercially available bioabsorbable fistula plug. Six weeks later, patients returned to the operating room for removal of the seton and placement of the stem cell-loaded plug. MAIN OUTCOME MEASURES: Patients were followed up for a total of 8 visits through 12 months. Safety was the primary end point; clinical healing and MRI response were secondary end points. RESULTS: Twenty patients (12 females; mean age 36 y) were treated with the stem cell-loaded plug. Of the 20 patients enrolled, 3 were not included in the 12-month analysis because of study withdrawal. Through 12 months, no patient experienced a serious adverse event related to the stem cell-loaded plug. Four patients experienced 7 serious adverse events and 12 patients experienced 22 adverse events. Complete clinical healing occurred in 14 of 18 patients at 6 months and 13 of 17 patients at 12 months. MRI response was observed in 12 of 18 patients at 6 months. LIMITATIONS: The main limitations were the small sample size and restrictive inclusion criteria. CONCLUSIONS: A stem cell-loaded plug can safely and effectively deliver cell-based therapy for patients with single-tract fistulizing perianal Crohn's disease. See Video Abstract at http://links.lww.com/DCR/C70 . RESPUESTA DURADERA OBSERVADA EN PACIENTES CON ENFERMEDAD DE CROHN PERIANAL FISTULIZANTE REFRACTARIA MEDIANTE EL USO DE CLULAS MADRE MESENQUIMALES AUTLOGAS EN UNA MATRIZ DISOLUBLE RESULTADOS DEL ENSAYO DE FASE I STEM CELL ON MATRIX PLUG: ANTECEDENTES:La enfermedad de Crohn perianal refractaria sigue siendo notoriamente difícil de tratar. Desarrollamos una tecnología novedosa utilizando un tapón de fístula bioabsorbible disponible comercialmente para administrar células madre mesenquimales derivadas de tejido adiposo autólogo.OBJETIVO:Evaluar la seguridad y viabilidad terapéutica en el ensayo finalizado STOMP.DISEÑO:Ensayo clínico prospectivo de fase I de un solo brazo.AJUSTE:Centro médico académico terciario.PACIENTES:Adultos (18-65) con fístula perianal compleja de la enfermedad de Crohn de un solo tracto que han fracasado con la terapia convencional.INTERVENCIÓN:Se aislaron células madre mesenquimales derivadas de tejido adiposo autólogo, se expandieron en cultivo ex vivo y se sembraron en un tapón de fístula bioabsorbible disponible comercialmente. Seis semanas después, los pacientes regresaron al quirófano para retirar el setón y colocar el tapón cargado de células madre.PRINCIPALES MEDIDAS DE RESULTADO:Los pacientes fueron seguidos durante un total de 8 visitas durante 12 meses. La seguridad fue el criterio principal de valoración; la curación clínica y la respuesta a la resonancia magnética fueron criterios de valoración secundarios.RESULTADOS:Veinte pacientes (12 mujeres, edad media 36 años) fueron tratados con el tapón cargado de células madre. De los 20 pacientes inscritos, tres no se incluyeron en el análisis de 12 meses porque se retiraron del estudio. A lo largo de 12 meses, ningún paciente experimentó un evento adverso grave relacionado con el tapón cargado de células madre. Cuatro pacientes experimentaron 7 eventos adversos graves y 12 pacientes experimentaron 22 eventos adversos. La curación clínica completa ocurrió en 14 de 18 pacientes a los 6 meses y en 13 de 17 pacientes a los 12 meses. La respuesta a la resonancia magnética se observó en 12 de 18 pacientes a los 6 meses.LIMITACIONES:Las principales limitaciones son el tamaño pequeño de la muestra y los criterios de inclusión restrictivos.CONCLUSIONES:Un tapón cargado de células madre se puede administrar de manera segura y efectiva, una terapia basada en células para pacientes con enfermedad de Crohn perianal fistulizante de un solo tracto. Consule Video Resumen en http://links.lww.com/DCR/C70 . (Traducción- Dr. Yesenia Rojas-Khalil ).


Asunto(s)
Enfermedad de Crohn , Células Madre Mesenquimatosas , Fístula Rectal , Adulto , Femenino , Humanos , Enfermedad de Crohn/complicaciones , Enfermedad de Crohn/terapia , Estudios Prospectivos , Fístula Rectal/etiología , Fístula Rectal/terapia , Estudios Retrospectivos , Células Madre
15.
AJR Am J Roentgenol ; 220(4): 551-560, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36259593

RESUMEN

Photon-counting detector (PCD) CT has emerged as a novel imaging modality that represents a fundamental shift in the way that CT systems detect x-rays. After pre-clinical and clinical investigations showed benefits of PCD CT for a range of imaging tasks, the U.S. FDA in 2021 approved the first commercial PCD CT system for clinical use. The technologic features of PCD CT are particularly well suited for musculo-skeletal imaging applications. Advantages of PCD CT compared with conventional energy-integrating detector (EID) CT include smaller detector pixels and excellent geometric dose efficiency that enable imaging of large joints and central skeletal anatomy at ultrahigh spatial resolution; advanced multienergy spectral postprocessing that allows quantification of gout deposits and generation of virtual noncalcium images for visualization of bone edema; improved metal artifact reduction for imaging of orthopedic implants; and higher CNR and suppression of electronic noise. Given substantially improved cortical and trabecular detail, PCD CT images more clearly depict skeletal abnormalities, including fractures, lytic lesions, and mineralized tumor matrix. The purpose of this article is to review, by use of clinical examples comparing EID CT and PCD CT, the technical features of PCD CT and their associated impact on musculoskeletal imaging applications.


Asunto(s)
Fotones , Tomografía Computarizada por Rayos X , Humanos , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Rayos X
16.
AJR Am J Roentgenol ; 220(1): 73-85, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35731096

RESUMEN

BACKGROUND. Anatomic redundancy between phases can be used to achieve denoising of multiphase CT examinations. A limitation of iterative reconstruction (IR) techniques is that they generally require use of CT projection data. A frequency-split multi-band-filtration algorithm applies denoising to the multiphase CT images themselves. This method does not require knowledge of the acquisition process or integration into the reconstruction system of the scanner, and it can be implemented as a supplement to commercially available IR algorithms. OBJECTIVE. The purpose of the present study is to compare radiologists' performance for low-contrast and high-contrast diagnostic tasks (i.e., tasks for which differences in CT attenuation between the imaging target and its anatomic background are subtle or large, respectively) evaluated on multiphase abdominal CT between routine-dose images and radiation dose-reduced images processed by a frequency-split multiband-filtration denoising algorithm. METHODS. This retrospective single-center study included 47 patients who underwent multiphase contrast-enhanced CT for known or suspected liver metastases (a low-contrast task) and 45 patients who underwent multiphase contrast-enhanced CT for pancreatic cancer staging (a high-contrast task). Radiation dose-reduced images corresponding to dose reduction of 50% or more were created using a validated noise insertion technique and then underwent denoising using the frequency-split multi-band-filtration algorithm. Images were independently evaluated in multiple sessions by different groups of abdominal radiologists for each task (three readers in the low-contrast arm and four readers in the high-contrast arm). The noninferiority of denoised radiation dose-reduced images to routine-dose images was assessed using the jackknife alternative free-response ROC (JAFROC) figure-of-merit (FOM; limit of noninferiority, -0.10) for liver metastases detection and using the Cohen kappa statistic and reader confidence scores (100-point scale) for pancreatic cancer vascular invasion. RESULTS. For liver metastases detection, the JAFROC FOM for denoised radiation dose-reduced images was 0.644 (95% CI, 0.510-0.778), and that for routine-dose images was 0.668 (95% CI, 0.543-0.792; estimated difference, -0.024 [95% CI, -0.084 to 0.037]). Intraobserver agreement for pancreatic cancer vascular invasion was substantial to near perfect when the two image sets were compared (κ = 0.53-1.00); the 95% CIs of all differences in confidence scores between image sets contained zero. CONCLUSION. Multiphase contrast-enhanced abdominal CT images with a radiation dose reduction of 50% or greater that undergo denoising by a frequency-split multiband-filtration algorithm yield performance similar to that of routine-dose images for detection of liver metastases and vascular staging of pancreatic cancer. CLINICAL IMPACT. The image-based denoising algorithm facilitates radiation dose reduction of multiphase examinations for both low- and high-contrast diagnostic tasks without requiring manufacturer-specific hardware or software.


Asunto(s)
Neoplasias Hepáticas , Tomografía Computarizada por Rayos X , Humanos , Estudios Retrospectivos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Algoritmos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
17.
Radiographics ; 43(1): e220119, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36459493

RESUMEN

MR defecating proctography (MRDP) is a noninvasive examination that can be used for evaluating posterior compartment disorders. MRDP has several advantages over conventional fluoroscopic defecography. These benefits include high-contrast resolution evaluation of the deep pelvic organs, simultaneous multicompartmental assessment that is performed statically and dynamically during defecation, and lack of ionizing radiation. MRDP also provides a highly detailed anatomic evaluation of the pelvic floor supportive structures, including direct assessment of the pelvic floor musculature and indirect assessment of the endopelvic fascia. As the breadth of knowledge regarding anatomic and functional posterior compartment disorders expands, so too does the advancement of noninvasive and surgical treatment options for these conditions. High-quality MRDP examinations, with key anatomic and functional features reported, guide treatment planning. Reporting of MRDP examination findings with use of standardized terminology that emphasizes objective measurements rather than subjective grading aids consistent communication among radiologists, clinicians, and surgeons. Familiarity with commonly encountered posterior compartment pelvic floor pathologic entities that contribute to posterior compartment disorders and awareness of the essential information needed by surgeons are key to providing an optimal multidisciplinary discussion for planning pelvic floor dysfunction treatment. The authors provide an overview of the basic concepts of the MRDP acquisition technique, the anatomic abnormalities of posterior compartment pelvic floor pathologic entities associated with defecatory disorders, and recently developed interdisciplinary MRDP reporting templates and lexicons. In addition, the associated imaging findings that are key for surgical treatment guidance are highlighted. © RSNA, 2022 Online supplemental material is available for this article.


Asunto(s)
Defecografía , Diafragma Pélvico , Humanos , Diafragma Pélvico/diagnóstico por imagen , Imagen por Resonancia Magnética , Radiólogos , Examen Físico
18.
Radiographics ; 43(5): e220158, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37022956

RESUMEN

Photon-counting detector (PCD) CT is an emerging technology that has led to continued innovation and progress in diagnostic imaging after it was approved by the U.S. Food and Drug Administration for clinical use in September 2021. Conventional energy-integrating detector (EID) CT measures the total energy of x-rays by converting photons to visible light and subsequently using photodiodes to convert visible light to digital signals. In comparison, PCD CT directly records x-ray photons as electric signals, without intermediate conversion to visible light. The benefits of PCD CT systems include improved spatial resolution due to smaller detector pixels, higher iodine image contrast, increased geometric dose efficiency to allow high-resolution imaging, reduced radiation dose for all body parts, multienergy imaging capabilities, and reduced artifacts. To recognize these benefits, diagnostic applications of PCD CT in musculoskeletal, thoracic, neuroradiologic, cardiovascular, and abdominal imaging must be optimized and adapted for specific diagnostic tasks. The diagnostic benefits and clinical applications resulting from PCD CT in early studies have allowed improved visualization of key anatomic structures and radiologist confidence for some diagnostic tasks, which will continue as PCD CT evolves and clinical use and applications grow. ©RSNA, 2023 Quiz questions for this article are available in the supplemental material. See the invited commentary by Ananthakrishnan in this issue.


Asunto(s)
Yodo , Tomografía Computarizada por Rayos X , Humanos , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Intensificación de Imagen Radiográfica/métodos , Fotones
19.
J Comput Assist Tomogr ; 47(4): 569-575, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36790898

RESUMEN

OBJECTIVE: This study aimed to determine the optimal photon energy for virtual monoenergetic images (VMI) in computed tomography angiography (CTA) using photon-counting-detector (PCD) CT. METHODS: Under institutional review board approval, 10 patients (abdominal, n = 4; lower extremity, n = 3; head and neck, n = 3) were scanned on an investigational PCD-CT (Count Plus, Siemens Healthcare) at 120 or 140 kV. All images were iteratively reconstructed with Bv48 kernel and 2-mm slice thickness. Axial and coronal VMI maximum-intensity projections were created in the range 40 to 65 keV (5-keV steps). Contrast-to-noise ratio (CNR) was calculated for major arteries in each VMI series. Two radiologists blindly ranked each VMI series for overall image quality and visualization of small vessels and pathology. The median and SD of scores for each photon energy were calculated. In addition, readers identified any VMIs that distinguished itself from others in terms of vessel/pathology visualization or artifacts. RESULTS: Mean iodine CNR was highest in 40-keV VMIs for all evaluated arteries. Across readers, the 50-keV VMI had the highest combined score (2.00 ± 1.11). Among different body parts, the 45-keV VMI was ranked highest for the head-and-neck (1.75 ± 0.68) and lower extremity (2.00 ± 1.41) CTA. Meanwhile, 50- and 55-keV VMIs were ranked highest for abdominal (2.50 ± 1.35 and 2.50 ± 1.56) CTA. The 40-keV VMI received the highest score for iodine visualization in vessels, and the 65-keV VMI for reduced metal/calcium-blooming artifacts. CONCLUSIONS: Quantitatively, VMIs at 40 keV had the highest CNR in major arterial vasculature using PCD-CTA. Based on radiologists' preference, the 45- and 50-keV VMIs were optimal for small body parts (eg, head and neck and lower extremity) and large body parts (eg, abdomen), respectively.


Asunto(s)
Yodo , Imagen Radiográfica por Emisión de Doble Fotón , Humanos , Angiografía por Tomografía Computarizada/métodos , Relación Señal-Ruido , Tomografía Computarizada por Rayos X/métodos , Cabeza , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Estudios Retrospectivos , Imagen Radiográfica por Emisión de Doble Fotón/métodos
20.
J Comput Assist Tomogr ; 47(2): 229-235, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36573321

RESUMEN

OBJECTIVE: To evaluate the diagnostic quality of photon-counting detector (PCD) computed tomography (CT) in patients undergoing lung cancer screening compared with conventional energy-integrating detector (EID) CT in a prospective multireader study. MATERIALS: Patients undergoing lung cancer screening with conventional EID-CT were prospectively enrolled and scanned on a PCD-CT system using similar automatic exposure control settings and reconstruction kernels. Three thoracic radiologists blinded to CT system compared PCD-CT and EID-CT images and scored examinations using a 5-point Likert comparison score (-2 [left image is worse] to +2 [left image is better]) for artifacts, sharpness, image noise, diagnostic image quality, emphysema visualization, and lung nodule evaluation focusing on the border. Post hoc correction of Likert scores was performed such that they reflected PCD-CT performance in comparison to EID-CT. A nonreader radiologist measured objective image noise. RESULTS: Thirty-three patients (mean, 66.9 ± 5.6 years; 11 female; body mass index; 30.1 ± 5.1 kg/m 2 ) were enrolled. Mean volume CT dose index for PCD-CT was lower (0.61 ± 0.21 vs 0.73 ± 0.22; P < 0.001). Pooled reader results showed significant differences between imaging modalities for all comparative rankings ( P < 0.001), with PCD-CT favored for sharpness, image noise, image quality, and emphysema visualization and lung nodule border, but not artifacts. Photon-counting detector CT had significantly lower image noise (74.4 ± 10.5 HU vs 80.1 ± 8.6 HU; P = 0.048). CONCLUSIONS: Photon-counting detector CT with similar acquisition and reconstruction settings demonstrated improved image quality and less noise despite lower radiation dose, with improved ability to depict pulmonary emphysema and lung nodule borders compared with EID-CT at low-dose lung cancer CT screening.


Asunto(s)
Enfisema , Neoplasias Pulmonares , Enfisema Pulmonar , Humanos , Femenino , Detección Precoz del Cáncer , Estudios Prospectivos , Neoplasias Pulmonares/diagnóstico por imagen , Fotones , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA