Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Anaesthesia ; 79(2): 211-212, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37989484
2.
Anaesthesist ; 59(11): 1003-4, 1006-7, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20835692

RESUMEN

Spontaneous ventilation is a popular mode of ventilation for patients with the laryngeal mask airway (LMA). Studies have shown, however, that spontaneous ventilation impairs gas exchange and that assisting or controlling ventilation results in higher oxygen saturation. Atelectasis during general anesthesia is a well described mechanism which impacts on gas exchange. Positive end-expiratory pressure (PEEP) increases the lung volume available for gas exchange. This study investigated whether the application of PEEP leads to an improvement of oxygen saturation in unassisted spontaneously breathing patients with a LMA. A total of 80 adult patients under general anesthesia were prospectively randomized into two groups. Both groups were left to breathe spontaneously. In group 1 the adjustable pressure limiting (APL) valve was opened resulting in zero end-expiratory pressure. In group 2 the valve was set to a PEEP of +7 cm H2O. Oxygen saturation was measured by pulse oxymetry at four different phases: pre-induction, after induction and insertion of the LMA, during maintenance and in recovery. The application of PEEP did not improve oxygen saturation. In both groups the mean oxygen saturation was similar (97.2±1.8% in group 1 versus 97.2±1.9% in group 2, p=0.941) during maintenance. No effect on oxygen saturation in recovery could be found either (96.0±1.8% in group 1 versus 96.1±2.0% in group 2, p=0.952) and hemodynamics were unaffected by the application of PEEP. The application of a PEEP of +7 cm H2O with a LMA under spontaneous ventilation cannot be recommended. Limitations of our study were the selection of healthy patients and omitting pre-oxygenation before induction which might have limited the development of atelectasis. In addition arterial partial pressure of oxygen (p(a)O2) measurements could have revealed subtle changes in oxygenation.


Asunto(s)
Anestesia General , Máscaras Laríngeas , Respiración con Presión Positiva , Respiración , Mecánica Respiratoria/fisiología , Adulto , Análisis de los Gases de la Sangre , Presión Sanguínea/fisiología , Femenino , Humanos , Masculino , Monitoreo Intraoperatorio , Oxígeno/sangre , Consumo de Oxígeno
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA