Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Blood Adv ; 7(17): 4773-4781, 2023 09 12.
Artículo en Inglés | MEDLINE | ID: mdl-36103340

RESUMEN

CITE was a prospective, noninterventional study in adult patients with chronic immune thrombocytopenia treated with eltrombopag under routine clinical care in Asia-Pacific, the Middle East, and Turkey. Data to assess eltrombopag usage, compliance, and outcomes were collected from May 2017 to December 2020. Platelet response was defined as platelet count ≥50 × 103/µL in the absence of rescue medications and splenectomy. Quality of life was evaluated using the Functional Assessment of Chronic Illness Therapy-Fatigue (FACIT-F) questionnaire. Noncompliance was defined as the number of missed doses and number of days where the patient did not follow food instructions. A total of 231 patients were enrolled; the median (range) duration of eltrombopag treatment was 484.5 (1-642) days. Compliance to prescribed eltrombopag dose since the previous routine visit was high at ≥96.0%. Baseline median platelet count was 19.0 × 103/µL, which increased to ≥50 × 103/µL at month 2 and mostly fluctuated between 70 × 103/µL and 100 × 103/µL thereafter. The median time to first platelet response was 1.05 (95% confidence interval: 0.92-1.28) months, and the median (interquartile range) maximum duration of platelet response was 193 (57-456) days. FACIT-F scores improved from a mean (standard deviation) 34.4 (12.1) at baseline to 38.5 (9.1) at month 18. Adverse events occurred in 50.9% of patients (n = 116), the most common being upper respiratory tract infection (8.3%) and headache (6.6%). These findings confirmed the effectiveness of eltrombopag treatment in routine practice and reassured that real-world compliance to eltrombopag-prescribed doses and dietary instructions in Asia-Pacific, the Middle East, and Turkey were in line with current recommendations.


Asunto(s)
Púrpura Trombocitopénica Idiopática , Adulto , Humanos , Púrpura Trombocitopénica Idiopática/tratamiento farmacológico , Púrpura Trombocitopénica Idiopática/inducido químicamente , Turquía , Calidad de Vida , Estudios Prospectivos , Enfermedad Crónica , Hidrazinas/efectos adversos , Asia
2.
Ultrasound Med Biol ; 40(10): 2445-57, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25023113

RESUMEN

Hemodynamic flow variations at low fluid shear stress are thought to play a critical role in local atherosclerotic plaque initiation and development and to affect plaque instability. Targeted microbubbles are being developed as intravascular agents for identifying atherosclerotic lesions using ultrasound. How variations in local hydrodynamic flow influence the adhesiveness of targeted microbubbles is not well understood. We postulated that rates of targeted microbubble binding and accumulation differ when subjected to steady flow (SF) as compared with oscillatory or pulsatile flow (PF), because PF imposes non-uniform blood rheology and periodic acceleration and deceleration of blood velocity, when compared with SF. We assessed the binding rates of targeted microbubbles in seven randomly assigned PF and seven matched SF replicate runs at low (<1 Pa) and intermediate (≥1 and <2.5 Pa) wall shear stress (WSS) by drawing 4.8 × 10(6) microbubbles mL(-1) over streptavidin-coated substrates, immobilized within a parallel plate flow chamber at a calculated density of 81 binding sites µm(-2). Selective binding and accumulation of targeted microbubbles was recorded in a single field of view using real-time video microscopy. Microbubble accumulation was modeled to obtain flow-mediated microbubble binding kinetics (amplitude, A, and rate constant, k). PF elicited higher microbubble accumulation rates, in comparison to SF. The rates of microbubble accumulation differed significantly between PF and SF (p < 0.05) at intermediate WSS but not at low WSS (p > 0.05). The rate of microbubble accumulation decreased as WSS increased.


Asunto(s)
Microburbujas , Ultrasonografía Doppler de Pulso , Arteriosclerosis/diagnóstico por imagen , Calibración , Diseño de Equipo , Microscopía por Video , Flujo Pulsátil , Reología , Estreptavidina , Estrés Mecánico , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA