Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 102(5): 864-877, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37668012

RESUMEN

BACKGROUND: The recent development and widespread adoption of antegrade dissection re-entry (ADR) techniques have been underlined as one of the antegrade strategies in all worldwide CTO consensus documents. However, historical wire-based ADR experience has suffered from disappointing long-term outcomes. AIMS: Compare technical success, procedural success, and long-term outcome of patients who underwent wire-based ADR technique versus antegrade wiring (AW). METHODS: One thousand seven hundred and ten patients, from the prospective European Registry of Chronic Total Occlusions (ERCTO), underwent 1806 CTO procedures between January 2018 and December 2021, at 13 high-volume ADR centers. Among all 1806 lesions attempted by the antegrade approach, 72% were approached with AW techniques and 28% with wire-based ADR techniques. RESULTS: Technical and procedural success rates were lower in wire-based ADR than in AW (90.3% vs. 96.4%, p < 0.001; 87.7% vs. 95.4%, p < 0.001, respectively); however, wire-based ADR was used successfully more often in complex lesions as compared to AW (p = 0.017). Wire-based ADR was used in most cases (85%) after failure of AW or retrograde procedures. At a mean clinical follow-up of 21 ± 15 months, major adverse cardiac and cerebrovascular events (MACCEs) did not differ between AW and wire-based ADR (12% vs. 15.1%, p = 0.106); both AW and wire-based ADR procedures were associated with significant symptom improvements. CONCLUSIONS: As compared to AW, wire-based ADR is a reliable and effective strategy successfully used in more complex lesions and often after the failure of other techniques. At long-term follow-up, patient's MACCEs and symptoms improvement were similar in both antegrade techniques.


Asunto(s)
Oclusión Coronaria , Intervención Coronaria Percutánea , Humanos , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/terapia , Resultado del Tratamiento , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Estudios Prospectivos , Angiografía Coronaria , Sistema de Registros , Enfermedad Crónica
2.
J Card Fail ; 20(2): 91-7, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24361803

RESUMEN

BACKGROUND: Despite chronic systemic anticoagulation, advanced heart failure patients treated with a continuous-flow left ventricular assist device (LVAD) remain at risk for pump thrombosis. Pump thrombosis may initially be suspected in the setting of clinical and biochemical evidence for intravascular hemolysis, putatively related to shear stress on red blood cells propelled through a partially occluded pump. Limited data exist to guide management in these patients. METHODS AND RESULTS: We present a series of 8 LVAD patients who presented with intravascular hemolysis secondary to pump thrombosis who were treated with intraventricular thrombolytic therapy. In 3 patients, thrombolytic therapy led to complete and lasting resolution of hemolysis, suggesting successful dissolution of pump thrombus. In the remaining 5 patients, thrombolytic therapy ultimately failed to halt or reverse pump thrombosis and hemolysis: 1 patient required emergent pump exchange, 2 patients progressed to cardiogenic shock and died, 1 patient suffered a debilitating stroke after which care was withdrawn, and 1 patient underwent cardiac transplantation. CONCLUSIONS: In the setting of LVAD thrombosis, thrombolytic therapy is an alternate treatment strategy in a subset of patients. Candidacy for this alternate procedure must carefully weigh the risks of complications, including hemorrhage and thromboembolism.


Asunto(s)
Corazón Auxiliar/efectos adversos , Terapia Trombolítica/métodos , Trombosis/tratamiento farmacológico , Trombosis/etiología , Activador de Tejido Plasminógeno/administración & dosificación , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
3.
J Thromb Thrombolysis ; 38(1): 73-7, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24469337

RESUMEN

A 75-year old woman with a history of coronary disease status post 3-vessel coronary artery bypass grafting (CABG) 8 years ago and a repeat one-vessel CABG 2 years ago in the setting of aortic valve replacement with a #19 mm St. Jude bileaflet mechanical valve for severe aortic stenosis presented with two to three weeks of progressive dyspnea and increasing substernal chest discomfort. Echocardiography revealed a gradient to 31 mmHg across her aortic valve, increased from a baseline of 13 mmHg five months previously. Fluoroscopy revealed thrombosis of her mechanical aortic valve. She was not a candidate for surgery given her multiple comorbidities, and fibrinolysis was contraindicated given a recent subdural hematoma 1 year prior to presentation. She was treated with heparin and eptifibatide and subsequently demonstrated resolution of her aortic valve thrombosis. We report the first described successful use of eptifibatide in addition to unfractionated heparin for the management of subacute valve thrombosis in a patient at high risk for repeat surgery or fibrinolysis.


Asunto(s)
Válvula Aórtica , Fibrinolíticos/administración & dosificación , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas/efectos adversos , Heparina/administración & dosificación , Péptidos/administración & dosificación , Inhibidores de Agregación Plaquetaria/administración & dosificación , Trombosis/tratamiento farmacológico , Anciano , Eptifibatida , Femenino , Fibrinólisis/efectos de los fármacos , Humanos , Trombosis/etiología
4.
Front Cardiovasc Med ; 10: 1185422, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37255702

RESUMEN

Background: The aim of this two-center, all-comers registry was to compare the effectiveness and safety of intravascular lithotripsy (IVL) to that of modified balloon angioplasty (MB). MB angioplasty using a cutting or scoring balloon is commonly used in patients with calcified coronary arteries. IVL is a new technology for lesion preparation. This is the first study to compare MB with IVL. Methods: The cohort included all patients treated by MB angioplasty or IVL between 2019 and 2021. The primary endpoint was strategy success (<20% residual stenosis). The secondary endpoint was long-term safety outcomes [cardiac death, acute myocardial infarction (AMI), target lesion failure/revascularization (TVR)]. Quantitative coronary angiography (QCA) was performed in all patients. Primary and secondary endpoints were compared using inverse probability of treatment weighting (IPTW) for treatment effect estimation. Results: A total of n = 86 patients were treated by IVL and n = 92 patients by MB angioplasty. The primary endpoint was reached in 152 patients (85.4%). Patients in the IVL group had less residual stenosis (5.8% vs. 22.8%; p = 0.001) in QCA. Weighted multivariable regression analysis revealed that IVL had a significant positive effect on reaching the primary endpoint of strategy success [odds ratio (OR) 24.58; 95% confidence interval (95% CI) 7.40-101.86; p = 0.001]. In addition, severe calcification was shown to result in a lower probability of achieving the primary endpoint (OR 0.08; 95% CI 0.02-0.24; p = 0.001). During the follow-up period (450 days) there was no difference in cardiovascular mortality rate [IVL (n = 5) 2.8% vs. MB (n = 3) 1.7%; p = 0.129]. Patients with unstable angina at the time of the index procedure had the highest probability of cardiovascular death [hazard ratio (HR) 7.136; 95% CI 1.248-40.802; p = 0.027]. No differences were found in long-term rates of AMI (IVL 1.7% vs. MB 2.8%; p = 0.399; IVL HR 2.73; 95% CI 0.4-17.0; p = 0.281) or TVR (IVL 5.6% vs. MB 9%; p = 0.186; IVL HR 0.78; 95% CI 0.277-2.166; p = 0.626). Conclusion: IVL leads to a significantly better angiographic intervention outcome compared to MB angioplasty in our cohort. During long-term follow-up, no differences in cardiovascular mortality, rate of acute myocardial infarction, or target lesion failure/revascularization were observed.

5.
J Thorac Cardiovasc Surg ; 164(5): 1532-1541.e2, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-34024615

RESUMEN

OBJECTIVES: Little data exist regarding the potential of external stents to mitigate long-term disease progression in saphenous vein grafts. We investigated the effect of external stents on the progression of saphenous vein graft disease. METHODS: A total of 184 patients undergoing isolated coronary artery bypass grafting, using an internal thoracic artery graft and at least 2 additional saphenous vein grafts, were enrolled in 14 European centers. One saphenous vein graft was randomized to an external stent, and 1 nonstented saphenous vein graft served as the control. The primary end point was the saphenous vein graft Fitzgibbon patency scale assessed by angiography, and the secondary end point was saphenous vein graft intimal hyperplasia assessed by intravascular ultrasound in a prespecified subgroup at 2 years. RESULTS: Angiography was completed in 128 patients and intravascular ultrasound in the entire prespecified cohort (n = 51) at 2 years. Overall patency rates were similar between stented and nonstented saphenous vein grafts (78.3% vs 82.2%, P = .43). However, the Fitzgibbon patency scale was significantly improved in stented versus nonstented saphenous vein grafts, with Fitzgibbon patency scale I, II, and III rates of 66.7% versus 54.9%, 27.8% versus 34.3%, and 5.5% versus 10.8%, respectively (odds ratio, 2.02; P = .03). Fitzgibbon patency scale was inversely related to saphenous vein graft minimal lumen diameter, with Fitzgibbon patency scale I, II, and III saphenous vein grafts having an average minimal lumen diameter of 2.62 mm, 1.98 mm, and 1.32 mm, respectively (P < .05). Externally stented saphenous vein grafts also showed significant reductions in mean intimal hyperplasia area (22.5%; P < .001) and thickness (23.5%; P < .001). CONCLUSIONS: Two years after coronary artery bypass grafting, external stenting improves Fitzgibbon patency scales of saphenous vein grafts and significantly reduces intimal hyperplasia area and thickness. Whether this will eventually lead to improved long-term patency is still unknown.


Asunto(s)
Enfermedad de la Arteria Coronaria , Vena Safena , Angiografía Coronaria , Puente de Arteria Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/cirugía , Progresión de la Enfermedad , Humanos , Hiperplasia/patología , Vena Safena/diagnóstico por imagen , Vena Safena/patología , Stents , Resultado del Tratamiento , Grado de Desobstrucción Vascular
6.
Eur J Cardiothorac Surg ; 62(1)2022 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-35312782

RESUMEN

OBJECTIVES: In a post hoc analysis of the VEST III trial, we investigated the effect of the harvesting technique on saphenous vein graft (SVG) patency and disease progression after coronary artery bypass grafting. METHODS: Angiographic outcomes were assessed in 183 patients undergoing open (126 patients, 252 SVG) or endoscopic harvesting (57 patients, 114 SVG). Overall SVG patency was assessed by computed tomography angiography at 6 months and by coronary angiography at 2 years. Fitzgibbon patency (FP I, II and III) and intimal hyperplasia (IH) in a patient subset were assessed by coronary angiography and intravascular ultrasound, respectively, at 2 years. RESULTS: Baseline characteristics were similar between patients who underwent open and those who underwent endoscopic harvesting. Open compared with endoscopic harvesting was associated with higher overall SVG patency rates at 6 months (92.9% vs 80.4%, P = 0.04) and 2 years (90.8% vs 73.9%, P = 0.01), improved FP I, II and III rates (65.2% vs 49.2%; 25.3% vs 45.9%, and 9.5% vs 4.9%, respectively; odds ratio 2.81, P = 0.09) and reduced IH area (-31.8%; P = 0.04) and thickness (-28.9%; P = 0.04). External stenting was associated with improved FP I, II and III rates (odds ratio 2.84, P = 0.01), reduced IH area (-19.5%; P < 0.001) and thickness (-25.0%; P < 0.001) in the open-harvest group and reduced IH area (-12.7%; P = 0.01) and thickness (-9.5%; P = 0.21) in the endoscopic-harvest group. CONCLUSIONS: A post-hoc analysis of the VEST III trial showed that open harvesting is associated with improved overall SVG patency and reduced IH. External stenting reduces SVG disease progression, particularly with open harvesting.


Asunto(s)
Enfermedad de la Arteria Coronaria , Vena Safena , Angiografía Coronaria , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria/métodos , Enfermedad de la Arteria Coronaria/cirugía , Progresión de la Enfermedad , Humanos , Vena Safena/trasplante , Grado de Desobstrucción Vascular
7.
J Heart Valve Dis ; 18(3): 284-8, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19557984

RESUMEN

BACKGROUND AND AIM OF THE STUDY: Pure annular dilation (PAD) is a recognized etiology of mitral regurgitation, yet few data exist to define the prognostic profile of this disorder relative to other etiologies, such as ischemia or myxomatous prolapse. METHODS: A total of 535 patients undergoing mitral repair at two institutions between 1993 and 2002 was retrospectively reviewed. PAD was defined as requiring only ring annuloplasty +/- cleft repair, without evidence of prolapse, regional wall motion abnormality, or infarction. RESULTS: PAD was identified in 74 patients, while alternative etiologies were myxomatous prolapse (n = 290), ischemia (n = 141), and 'other' (n = 30). PAD patients were more often female (78%) than male (38%) (p < 0.001), more often hypertensive (37% versus 26%; p = 0.003), and had a left ventricular ejection fraction (LVEF) that was lower (0.41 +/- 0.12) than those in patients with prolapse (0.51 +/- 0.11; p < 0.01) but similar to values in ischemic patients (0.38 +/- 0.10). The valve size was smaller for PAD versus prolapse (ring size 24-26 mm in 71% versus 12%; p < 0.001). The unadjusted PAD prognosis was intermediate, with five-year survival being 70 +/- 8%, compared to 87 +/- 3% for prolapse and 56 +/- 5% for ischemia (p < 0.01). Survival adjusted for differences in baseline characteristics was not different among the three groups (p > 0.10). CONCLUSION: PAD is a clinically distinct etiology of mitral regurgitation associated with female gender, small valve size, a lower LVEF, and hypertension. Early, more aggressive hypertension control might improve or minimize the consequences of this predominantly female cardiac disorder.


Asunto(s)
Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/patología , Válvula Mitral/patología , Caracteres Sexuales , Adulto , Anciano , Dilatación Patológica/complicaciones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/fisiopatología , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/cirugía , Prolapso de la Válvula Mitral/complicaciones , Isquemia Miocárdica/complicaciones , Estudios Retrospectivos , Volumen Sistólico/fisiología , Disfunción Ventricular Izquierda/patología , Disfunción Ventricular Izquierda/fisiopatología
8.
J Biomech ; 41(14): 2906-11, 2008 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-18804766

RESUMEN

Atherosclerotic plaque rupture is the major cause of acute coronary syndromes. Currently, there is no reliable diagnostic tool to predict plaque rupture. Knowledge of plaque mechanical properties based on local artery wall strain measurements would be useful for characterizing its composition and predicting its vulnerability. Due to cardiac motion, strain estimation in clinical intravascular ultrasound (IVUS) images is extremely challenging. A method is presented to estimate cross-sectional coronary artery wall strain in response to cardiac pulsatile pressure using clinically acquired IVUS images, which are acquired in continuous pullback mode. First, cardiac phase information is retrieved retrospectively from an IVUS image sequence using an image-based gating method, and image sub-sequences at systole and diastole are extracted. Then, images at branch sites are used as landmarks to align the two image sub-sequences. Finally, the paired images at each site are registered to measure the 2D strain tensor of the coronary artery cross-section. This method has been successfully applied to IVUS images of a left anterior descending (LAD) coronary artery acquired clinically during a standard procedure. Such complete strain information should be useful for identifying vulnerable plaque.


Asunto(s)
Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiología , Diagnóstico por Imagen de Elasticidad/métodos , Interpretación de Imagen Asistida por Computador/métodos , Modelos Cardiovasculares , Ultrasonografía Intervencional/métodos , Simulación por Computador , Módulo de Elasticidad , Humanos , Sensibilidad y Especificidad , Estrés Mecánico
10.
J Matern Fetal Neonatal Med ; 19(9): 543-9, 2006 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16966122

RESUMEN

BACKGROUND: Pregnancy in a woman with a mechanical heart valve is a life-threatening situation. Due to the inability of unfractionated heparin to prevent valvular thromboses, warfarin or other vitamin K antagonists have been the preferred anticoagulants for the mother. They are, however, potentially harmful to the fetus. With the advent of low-molecular-weight heparins, clinicians were hopeful for an alternative that was safe for the fetus, but more effective than unfractionated heparin, which carries a 29-33% risk of life-threatening thromboses and a 7-15% chance of mortality. Unfortunately, fatal thromboses have occurred with low-molecular-weight heparin as well. METHODS: We searched the MEDLINE database and other sources to identify cases of the use of low-molecular-weight heparin for thromboprophylaxis in women with mechanical heart valves. RESULTS: We found 73 cases and added three of our own for a total of 76. There were 17 thrombotic events (22%). Thirteen were valve thromboses, two were strokes, and two were myocardial infarctions. There were three deaths (4%). CONCLUSIONS: While pregnant women with mechanical heart valves who receive low-molecular-weight heparin for thromboprophylaxis are at extremely high risk of life-threatening thromboses, there is no evidence that low-molecular-weight heparin is inferior to unfractionated heparin.


Asunto(s)
Anticoagulantes/uso terapéutico , Prótesis Valvulares Cardíacas , Heparina de Bajo-Peso-Molecular/uso terapéutico , Complicaciones Cardiovasculares del Embarazo/tratamiento farmacológico , Trombosis/prevención & control , Anticoagulantes/efectos adversos , Femenino , Heparina de Bajo-Peso-Molecular/efectos adversos , Humanos , Embarazo , Riesgo , Trombosis/epidemiología
11.
J Am Coll Cardiol ; 68(4): 356-65, 2016 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-27443431

RESUMEN

BACKGROUND: Hybrid coronary revascularization (HCR) combines minimally invasive surgical coronary artery bypass grafting of the left anterior descending artery with percutaneous coronary intervention (PCI) of non-left anterior descending vessels. HCR is increasingly used to treat multivessel coronary artery disease that includes stenoses in the proximal left anterior descending artery and at least 1 other vessel, but its effectiveness has not been rigorously evaluated. OBJECTIVES: This National Institutes of Health-funded, multicenter, observational study was conducted to explore the characteristics and outcomes of patients undergoing clinically indicated HCR and multivessel PCI for hybrid-eligible coronary artery disease, to inform the design of a confirmatory comparative effectiveness trial. METHODS: Over 18 months, 200 HCR and 98 multivessel PCI patients were enrolled at 11 sites. The primary outcome was major adverse cardiac and cerebrovascular events (MACCE) (i.e., death, stroke, myocardial infarction, repeat revascularization) within 12 months post-intervention. Cox proportional hazards models were used to model time to first MACCE event. Propensity scores were used to balance the groups. RESULTS: Mean age was 64.2 ± 11.5 years, 25.5% of patients were female, 38.6% were diabetic, and 4.7% had previous stroke. Thirty-eight percent had 3-vessel coronary artery disease, and the mean SYNTAX (Synergy Between PCI With Taxus and Cardiac Surgery) score was 19.7 ± 9.6. Adjusted for baseline risk, MACCE rates were similar between groups within 12 months post-intervention (hazard ratio [HR]: 1.063; p = 0.80) and during a median 17.6 months of follow-up (HR: 0.868; p = 0.53). CONCLUSIONS: These observational data from this first multicenter study of HCR suggest that there is no significant difference in MACCE rates over 12 months between patients treated with multivessel PCI or HCR, an emerging modality. A randomized trial with long-term outcomes is needed to definitively compare the effectiveness of these 2 revascularization strategies. (Hybrid Revascularization Observational Study; NCT01121263).


Asunto(s)
Puente de Arteria Coronaria/métodos , Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/cirugía , Stents Liberadores de Fármacos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Intervención Coronaria Percutánea/métodos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento
12.
J Thorac Cardiovasc Surg ; 129(6): 1405-13, 2005 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-15942585

RESUMEN

OBJECTIVES: Fifty percent of human aortocoronary saphenous vein grafts are occluded after 10 years. Intimal hyperplasia is an initial step in graft occlusion and consists of vascular smooth muscle cell proliferation. Phosphatidylinositol 3-kinase and its downstream regulator, the inositol 3-phosphatase PTEN (phosphatase and tensin homolog deleted on chromosome 10), are important regulators of vascular smooth muscle cell proliferation, migration, and cell death. This study tests whether overexpression of PTEN in aortocoronary saphenous vein grafts can reduce intimal hyperplasia. METHODS: Adult dogs underwent aortocoronary bypass grafting to the left anterior descending artery by using the autologous saphenous vein. Saphenous vein grafts were treated with phosphate-buffered saline (n = 9), empty adenovirus (n = 8), or adenovirus encoding for PTEN (n = 8). Arteriography at 30 and 90 days assessed saphenous vein graft patency. A subset received saphenous vein grafts treated with a marker transgene (beta-galactosidase, n = 3), empty adenovirus (n = 4), or adenovirus encoding for PTEN (n = 4) and were killed on postoperative day 3 to confirm expression. Vascular smooth muscle cells were isolated from canine saphenous vein infected with adenovirus encoding for PTEN, and immunoblotting and proliferation assays were performed. RESULTS: Saphenous vein graft transgene expression was confirmed by means of immunohistochemistry, immunoblotting, and polymerase chain reaction. Arteriograms revealed all saphenous vein grafts to be patent. Saphenous vein grafts treated with adenovirus encoding for PTEN demonstrated reduced intimal area compared with those treated with empty adenovirus and phosphate-buffered saline (1.39 +/- 0.11 vs 2.35 +/- 0.3 and 2.57 +/- 0.4 mm 2 , P < .05), and the intima/media ratio was lower in saphenous vein grafts treated with adenovirus encoding for PTEN (0.50 +/- 0.05 vs 1.43 +/- 0.18 and 1.11 +/- 0.14, P < .005). PTEN overexpression in vascular smooth muscle cells inhibited platelet-derived growth factor-induced phosphorylation of Akt, a downstream effector of phosphatidylinositol 3-kinase. PTEN-treated vascular smooth muscle cells demonstrated decreased basal, platelet-derived growth factor-stimulated, and serum-stimulated proliferation. CONCLUSION: This study demonstrates that PTEN overexpression in aortocoronary saphenous vein grafts reduces intimal hyperplasia. The mechanism of this antiproliferative effect in vascular smooth muscle cells is likely due to inhibition of phosphatidylinositol 3-kinase signaling through Akt, with resultant decreases in vascular smooth muscle cell growth and survival. Therefore modulation of the phosphatidylinositol 3-kinase pathway through PTEN overexpression might represent a novel therapy to prevent saphenous vein graft intimal hyperplasia after coronary artery bypass grafting.


Asunto(s)
Puente de Arteria Coronaria , Oclusión de Injerto Vascular/etiología , Fosfatidilinositol 3-Quinasas/fisiología , Vena Safena/patología , Vena Safena/trasplante , Túnica Íntima/patología , Animales , División Celular , Perros , Hiperplasia , Músculo Liso Vascular/patología , Transducción de Señal
13.
Clin Nucl Med ; 30(4): 262-4, 2005 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15764886

RESUMEN

The authors report a case of a left-sided silicone breast implant interfering with nuclear imaging of the myocardium. Cardiac SPECT imaging of a woman documented widespread infarct in the anterolateral, inferior, and posterolateral walls, as well as mixed ischemia/infarct in the anterior wall. Subsequent cardiac MRI revealed just anterolateral and inferolateral infarct. The anterior wall was completely viable. Also apparent on the MR images was a left breast implant overlying the anterior myocardial wall. This case of a left-sided silicone breast implant interfering with nuclear imaging of the myocardium highlights the importance of understanding the potential interference from silicone breast implants.


Asunto(s)
Artefactos , Implantes de Mama , Errores Diagnósticos/prevención & control , Cuerpos Extraños/diagnóstico por imagen , Corazón/diagnóstico por imagen , Infarto del Miocardio/diagnóstico por imagen , Siliconas , Anciano , Diagnóstico Diferencial , Femenino , Cuerpos Extraños/diagnóstico , Humanos , Imagen por Resonancia Magnética , Infarto del Miocardio/diagnóstico , Cintigrafía
14.
J Thorac Cardiovasc Surg ; 127(1): 27-33, 2004 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-14752409

RESUMEN

OBJECTIVE: More than 50% of aortocoronary saphenous vein grafts are occluded 10 years after surgery. Intimal hyperplasia is an initial, critical step in the progression toward occlusion. To date, no clinically relevant large animal models of aortocoronary saphenous vein graft intimal hyperplasia have been fully characterized. Gene therapy holds promise as a novel treatment for aortocoronary saphenous vein graft intimal hyperplasia. The 2 objectives of this study are to characterize a canine model of aortocoronary saphenous vein graft intimal hyperplasia and to demonstrate that ex vivo gene delivery is possible in these grafts using adenoviral vectors. METHODS: Ten dogs underwent aortocoronary bypass grafting using saphenous veins. Six dogs underwent serial arteriograms to monitor graft patency. On postoperative day 90, the dogs were killed and their grafted and nongrafted saphenous veins were studied histologically. Four dogs underwent the same procedure, but their saphenous veins were treated with 1 x 10(12) total viral particles of a replication-deficient, recombinant adenovirus containing beta-galactosidase (n = 2) or the beta-adrenergic receptor kinase carboxyl terminus (n = 2). These animals were killed on postoperative day 7 for determination of transgene expression. RESULTS: All grafts were demonstrated patent by arteriogram before the animals were killed. The mean intimal area of the saphenous vein grafts was increased when compared with that of the nongrafted saphenous veins (2.83 mm(2) vs 0.09 mm(2), P <.0008). Adenoviral-treated saphenous vein grafts demonstrated positive transgene expression either by X-gal staining (beta-galactosidase) or Northern analysis (beta-adrenergic receptor kinase carboxyl terminus). CONCLUSION: This study characterizes a clinically relevant canine model of aortocoronary saphenous vein graft intimal hyperplasia. In addition, it demonstrates that adenoviral vectors can be delivered ex vivo to the saphenous vein graft vessel wall at subphysiologic distension pressures. This model may be used in future studies to manipulate molecular targets critical in aortocoronary saphenous vein graft intimal hyperplasia.


Asunto(s)
Puente de Arteria Coronaria/métodos , Terapia Genética/métodos , Oclusión de Injerto Vascular/prevención & control , Vena Safena/trasplante , Túnica Íntima/patología , Animales , Aortografía , Biopsia con Aguja , Modelos Animales de Enfermedad , Perros , Femenino , Técnicas de Transferencia de Gen , Oclusión de Injerto Vascular/diagnóstico por imagen , Hiperplasia/diagnóstico por imagen , Hiperplasia/prevención & control , Inmunohistoquímica , Masculino , Probabilidad , Medición de Riesgo , Vena Safena/patología , Sensibilidad y Especificidad , Resultado del Tratamiento , Grado de Desobstrucción Vascular/fisiología
15.
J Biomech ; 36(5): 689-97, 2003 May.
Artículo en Inglés | MEDLINE | ID: mdl-12694999

RESUMEN

Stents have dramatically improved the treatment of coronary artery disease. Since the implantation of stents changes the geometry and dynamics of the coronary artery, it is reasonable to hypothesize that some of these changes may have an important effect on the development of atherosclerosis by modulating the mechanical environment. In this paper, we presented a method to compare the geometric dynamics of the coronary artery before and after stenting using biplane angiography. Two cases are reviewed and a number of parameters are proposed to describe the longitudinal change of the vessel before and after stenting. This analysis technique has the potential to identify some aspects of stent design and procedure that might improve the success rate with this therapeutic approach.


Asunto(s)
Cineangiografía/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Stents , Arterias/fisiopatología , Vasos Coronarios/fisiopatología , Vasos Coronarios/cirugía , Humanos , Imagenología Tridimensional/métodos , Movimiento (Física) , Cuidados Posoperatorios , Cuidados Preoperatorios
16.
Hellenic J Cardiol ; 54(1): 69-76, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23340133

RESUMEN

The combination of a giant coronary aneurysm with multiple coronary aneurysms in adults is an extremely rare entity--especially in atherosclerotic patients, since it is most commonly associated with Kawasaki disease in children. We report an interesting case of a 59-year-old male patient with multiple atherosclerotic aneurysms of the left coronary system and a giant aneurysm of the right coronary artery. The patient was admitted to our hospital because of a non-ST myocardial infarction. Diagnosis was established by echocardiography, computed tomography angiogram, and coronary angiography. In view of the clinical symptoms and the extent of the giant right coronary aneurysm, with the associated risk of rupture, the patient was successfully treated with urgent surgical intervention. We also present a review of the current literature on this anomaly and a statistical analysis of all atherosclerotic giant coronary artery aneurysms previously reported.


Asunto(s)
Aneurisma Coronario/complicaciones , Enfermedad de la Arteria Coronaria/complicaciones , Infarto del Miocardio/complicaciones , Adulto , Aneurisma Coronario/diagnóstico , Angiografía Coronaria , Ecocardiografía , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico , Tomografía Computarizada por Rayos X
19.
Int J Cardiol ; 135(1): 43-52, 2009 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-18597872

RESUMEN

BACKGROUND: The non-uniform distribution of atherosclerosis in the human vasculature suggests that local fluid dynamics or wall mechanics may be involved in atherogenesis. Thus certain aspects of vascular geometry, which mediates both fluid dynamics and wall mechanics, might be risk factors for coronary atherosclerosis. Cataloguing the geometry of normal human coronary arteries and its variability is a first step toward identifying specific geometric features that increase vascular susceptibility to the disease. METHODS: Images of angiographically normal coronary arteries, including 32 left anterior descending (LAD) and 35 right coronary arteries (RCA), were acquired by clinical biplane cineangiography from 52 patients. The vessel axes in end diastole were reconstructed and geometric parameters that included measures of curvature, torsion and tortuosity were quantified for the proximal, middle and distal segments of the arteries. RESULTS: Statistical analysis shows that (1) in the LAD, curvature, torsion and tortuosity are generally highest in the distal portion, (2) in the RCA, these parameters are smallest in the middle segment, (3) the LAD exhibits significant higher torsion than the RCA (P < 0.005), and (4) >80% of the variability of coronary arterial geometry can be expressed in terms of two factors, one dominated by the curvature measures and tortuosity, and the other emphasizing the torsion parameters. CONCLUSIONS: This study has comprehensively documented the normal arterial geometry of the LAD and RCA in end diastole. This information may be used to guide the identification of geometric features that might be atherogenic risk factors.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/epidemiología , Modelos Cardiovasculares , Adulto , Enfermedad de la Arteria Coronaria/fisiopatología , Diástole , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Factores de Riesgo , Torsión Mecánica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA