Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Artif Organs ; 26(4): 275-286, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36208373

RESUMEN

Patients with left ventricular assist devices (LVADs) receive anticoagulation to decrease the risk of thrombosis. Various circumstances require discontinuing anticoagulation in LVAD patients, but the risks entailed are not well defined. In a retrospective review of LVAD implantation procedures, we examined the effect of time off anticoagulation on thrombosis and mortality rates after implantation. An international normalized ratio ≤ 1.5 was used to screen for patients taken off anticoagulation. Patients were divided into three groups by the cumulative number of days off anticoagulation: no discontinuation, short-term discontinuation (< 30 days), and long-term discontinuation (≥ 30 days). Rates of ischemic stroke, pump thrombosis, and mortality were compared among groups. Of 245 patients who underwent LVAD implantation during the study, 70 (28.6%) were off anticoagulation during follow-up: 37 (15.1%) had short-term discontinuation (median, 11 days), and 33 (13.5%) had long-term discontinuation (median, 124 days). Patients with long-term discontinuation had a higher rate of ischemic stroke (adjusted hazard ratio 8.5, p = 0.001) and death (adjusted hazard ratio 3.9, p = 0.001). The three groups did not differ in pump thrombosis rate. We conclude that after LVAD implantation, discontinuing anticoagulation for ≥ 30 days is independently associated with an increased risk of ischemic stroke and death.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Accidente Cerebrovascular Isquémico , Trombosis , Humanos , Corazón Auxiliar/efectos adversos , Insuficiencia Cardíaca/cirugía , Insuficiencia Cardíaca/complicaciones , Trombosis/etiología , Trombosis/prevención & control , Estudios Retrospectivos , Anticoagulantes/uso terapéutico , Accidente Cerebrovascular Isquémico/inducido químicamente , Accidente Cerebrovascular Isquémico/complicaciones , Resultado del Tratamiento
2.
J Artif Organs ; 21(3): 285-292, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29766321

RESUMEN

Continuous-flow left ventricular assist devices (CF-LVADs) are increasingly being used to treat advanced, refractory chronic heart failure. Herein, we sought to determine the incidence of postoperative acute kidney injury (AKI) in axial-flow (HeartMate II; HM-II) and centrifugal-flow (HVAD) CF-LVAD recipients, as well as the effect of AKI on mortality. The study cohort comprised 520 patients who received a HM-II (n = 398) or HVAD (n = 122) at our center between November 2003 and March 2016. Their records were reviewed to determine the incidence of RIFLE-defined AKI after LVAD implantation. We compared the perioperative characteristics, postoperative complications, and survival rates of the patients with and without AKI and differentiated the outcomes based on device type (HM-II or HVAD). Seventy-five patients (14.4%) developed AKI postoperatively. Patients with AKI after LVAD implantation had significantly reduced survival compared to patients without AKI (p = 0.01). Cox proportional hazards models showed that AKI was a significant independent predictor of mortality (HR = 1.54, p = 0.03). Preoperative mechanical circulatory support and prolonged cardiopulmonary bypass time were independent predictors of AKI. The incidence of AKI was similar for HM-II and HVAD recipients (p = 0.25). There was no significant difference in AKI rates for the HM-II and HVAD recipients. Developing AKI adversely affected survival.


Asunto(s)
Lesión Renal Aguda/etiología , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Complicaciones Posoperatorias , Lesión Renal Aguda/epidemiología , Diseño de Equipo , Falla de Equipo , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tasa de Supervivencia/tendencias , Estados Unidos/epidemiología
3.
ASAIO J ; 68(12): 1443-1449, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-36150083

RESUMEN

Patients with severe refractory hypoxemic respiratory failure may benefit from extracorporeal membrane oxygenation (ECMO) for salvage therapy. The Coronavirus disease 2019 (COVID-19) pandemic offered three high-volume independent ECMO programs at a large medical center the chance to collaborate to optimize ECMO care at the beginning of the pandemic in Spring 2020. Between March 15, 2020, and May 30, 2020, 3,615 inpatients with COVID-19 were treated at the Texas Medical Center. During this time, 35 COVID-19 patients were cannulated for ECMO, all but one in a veno-venous configuration. At hospital discharge, 23 (66%) of the 35 patients were alive. Twelve patients died of vasodilatory shock (n = 9), intracranial hemorrhage (n = 2), and cannulation-related bleeding and multiorgan dysfunction (n = 1). The average duration of ECMO was 13.6 days in survivors and 25.0 days in nonsurvivors ( p < 0.04). At 1 year follow-up, all 23 discharged patients were still alive, making the 1 year survival rate 66% (23/35). At 2 years follow-up, the overall rate of survival was 63% (22/35). Of those patients who survived 2 years, all were at home and alive and well at follow-up.


Asunto(s)
COVID-19 , Oxigenación por Membrana Extracorpórea , Humanos , COVID-19/terapia , Estudios de Seguimiento , Texas/epidemiología , Hospitales
4.
Gen Thorac Cardiovasc Surg ; 68(11): 1278-1284, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32338333

RESUMEN

OBJECTIVE: Warfarin is standard anticoagulation therapy for patients with a continuous-flow left ventricular assist device (CF-LVAD). However, warfarin requires regular monitoring and dosage adjustments and fails for many patients, causing thromboembolic and bleeding events. Factor Xa inhibitors have been shown to be noninferior to warfarin in preventing strokes and are associated with less intracranial hemorrhage in patients with atrial fibrillation. We evaluated treatment safety and effectiveness in CF-LVAD patients who switched from warfarin to a factor Xa inhibitor (apixaban or rivaroxaban) after warfarin failure. METHODS: This was a retrospective, single-center study of patients treated between 2008 and 2018. We assessed the occurrence of stroke, non-central nervous system (CNS) embolism, pump thrombosis, and major gastrointestinal bleeding and intracranial hemorrhage during therapy. RESULTS: We identified seven patients: five were male, the average body mass index was 30 kg/m2, and average age was 56 years. Preimplantation comorbidities included hypertension (all patients) and diabetes mellitus, ischemic cardiomyopathy, atrial fibrillation, and previous myocardial infarction (four patients each). Overall, patients received warfarin for 3968 days and apixaban/rivaroxaban for 1459 days. The warfarin group was within the therapeutic INR range (2.0-3.0) 30% of the time. Complication rates did not differ between warfarin and apixaban/rivaroxaban: strokes, 0.20 vs none, non-CNS embolism, 0.54 vs none; pump thrombosis, 0.27 vs none; major gastrointestinal bleeding, 0.20 vs 0.50; intracranial hemorrhage, 0.13 vs none. CONCLUSIONS: Factor Xa inhibitors may be viable treatment options for CF-LVAD patients for whom warfarin therapy has failed. Large prospective studies are necessary to confirm these results.


Asunto(s)
Inhibidores del Factor Xa/administración & dosificación , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Pirazoles/administración & dosificación , Piridonas/administración & dosificación , Rivaroxabán/administración & dosificación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Accidente Cerebrovascular/prevención & control , Tromboembolia/prevención & control , Resultado del Tratamiento , Warfarina/administración & dosificación
5.
J Invasive Cardiol ; 32(7): 255-261, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32507753

RESUMEN

OBJECTIVES: To evaluate the safety and accuracy of the Early Bird Bleed Monitoring System (EBBMS; Saranas) for the detection of access-site related bleeds in humans undergoing endovascular procedures. BACKGROUND: Bleeding complications after endovascular procedures are frequent and associated with poor prognosis. The EBBMS is a novel technology designed to detect in real time the onset, progression, and severity of internal bleeds. METHODS: The EBBMS was used during and after endovascular procedures, either as a venous or arterial access sheath. The primary endpoint was the level of agreement in bleed detection between the Saranas EBBMS and postprocedural computed tomography. RESULTS: From August 2018 to December 2018, a total of 60 patients from five United States sites were enrolled and underwent elective endovascular procedures (transcatheter aortic valve replacement [67%], percutaneous coronary intervention [13%], percutaneous ventricular assist device [8%], balloon aortic valvuloplasty [7%], transcatheter mitral valve repair/replacement [4%], and endovascular aneurysmal repair [2%]). The EBBMS detected the absence of bleeds in 21 patients (35%) and bleeds in 39 patients (65%), with bleeding severity level 1 in 20 patients (33%), level 2 in 15 patients (25%), and level 3 in 4 patients (7%). Bleeding detection occurred during the procedure in 31% of patients and post procedure in 69% of patients. The level of agreement between the EBBMS and computed tomography scan was high (Cohen's kappa=0.84). No device-related complications were reported. CONCLUSIONS: The EBBMS was safe across a variety of endovascular procedures and detected bleeding events with a high level of agreement with postprocedural computed tomography scan.


Asunto(s)
Procedimientos Endovasculares , Hemorragia , Valvuloplastia con Balón , Procedimientos Endovasculares/efectos adversos , Hemorragia/diagnóstico , Hemorragia/epidemiología , Hemorragia/etiología , Humanos , Reemplazo de la Válvula Aórtica Transcatéter , Resultado del Tratamiento
7.
J Heart Lung Transplant ; 33(5): 470-7, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24656391

RESUMEN

BACKGROUND: Continuous-flow left ventricular assist devices (LVADs) expose blood cells to high shear stress, potentially resulting in the production of microparticles that express phosphatidylserine (PS+) and promote coagulation and inflammation. In this prospective study, we attempted to determine whether PS+ microparticle levels correlate with clinical outcomes in LVAD-supported patients. METHODS: We enrolled 20 patients undergoing implantation of the HeartMate II LVAD (Thoratec Corp, Pleasanton, CA) and 10 healthy controls who provided reference values for the microparticle assays. Plasma was collected before LVAD implantation, at discharge, at the 3-month follow-up, and when an adverse clinical event occurred. We quantified PS+ microparticles in the plasma using flow cytometry. RESULTS: During the study period, 8 patients developed adverse clinical events: ventricular tachycardia storm in 1, non-ST-elevation myocardial infarction in 2, arterial thrombosis in 2, gastrointestinal bleeding in 2, and stroke in 3. Levels of PS+ microparticles were higher in patients at baseline than in healthy controls (2.11% ± 1.26% vs 0.69% ± 0.46%, p = 0.007). After LVAD implantation, patient PS+ microparticle levels increased to 2.39% ± 1.22% at discharge and then leveled to 1.97% ± 1.25% at the 3-month follow-up. Importantly, levels of PS+ microparticles were significantly higher in patients who developed an adverse event than in patients with no events (3.82% ± 1.17% vs 1.57% ± 0.59%, p < 0.001), even though the 2 patient groups did not markedly differ in other clinical and hematologic parameters. CONCLUSIONS: Our results suggest that an elevation of PS+ microparticle levels may be associated with adverse clinical events. Thus, measuring PS+ microparticle levels in LVAD-supported patients may help identify patients at increased risk for adverse events.


Asunto(s)
Micropartículas Derivadas de Células , Insuficiencia Cardíaca/terapia , Trasplante de Corazón , Corazón Auxiliar/efectos adversos , Citometría de Flujo , Estudios de Seguimiento , Insuficiencia Cardíaca/sangre , Humanos , Proyectos Piloto , Estudios Prospectivos , Factores de Riesgo , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA