Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Lancet ; 402(10408): 1147-1157, 2023 09 30.
Artículo en Inglés | MEDLINE | ID: mdl-37634520

RESUMEN

BACKGROUND: Continuous automatic optimisation of cardiac resynchronisation therapy (CRT), stimulating only the left ventricle to fuse with intrinsic right bundle conduction (synchronised left ventricular stimulation), might offer better outcomes than conventional CRT in patients with heart failure, left bundle branch block, and normal atrioventricular conduction. This study aimed to compare clinical outcomes of adaptive CRT versus conventional CRT in patients with heart failure with intact atrioventricular conduction and left bundle branch block. METHODS: This global, prospective, randomised controlled trial was done in 227 hospitals in 27 countries across Asia, Australia, Europe, and North America. Eligible patients were aged 18 years or older with class 2-4 heart failure, an ejection fraction of 35% or less, left bundle branch block with QRS duration of 140 ms or more (male patients) or 130 ms or more (female patients), and a baseline PR interval 200 ms or less. Patients were randomly assigned (1:1) via block permutation to adaptive CRT (an algorithm providing synchronised left ventricular stimulation) or conventional biventricular CRT using a device programmer. All patients received device programming but were masked until procedures were completed. Site staff were not masked to group assignment. The primary outcome was a composite of all-cause death or intervention for heart failure decompensation and was assessed in the intention-to-treat population. Safety events were collected and reported in the intention-to-treat population. This study is registered with ClinicalTrials.gov, NCT02205359, and is closed to accrual. FINDINGS: Between Aug 5, 2014, and Jan 31, 2019, of 3797 patients enrolled, 3617 (95·3%) were randomly assigned (1810 to adaptive CRT and 1807 to conventional CRT). The futility boundary was crossed at the third interim analysis on June 23, 2022, when the decision was made to stop the trial early. 1568 (43·4%) of 3617 patients were female and 2049 (56·6%) were male. Median follow-up was 59·0 months (IQR 45-72). A primary outcome event occurred in 430 of 1810 patients (Kaplan-Meier occurrence rate 23·5% [95% CI 21·3-25·5] at 60 months) in the adaptive CRT group and in 470 of 1807 patients (25·7% [23·5-27·8] at 60 months) in the conventional CRT group (hazard ratio 0·89, 95% CI 0·78-1·01; p=0·077). System-related adverse events were reported in 452 (25·0%) of 1810 patients in the adaptive CRT group and 440 (24·3%) of 1807 patients in the conventional CRT group. INTERPRETATION: Compared with conventional CRT, adaptive CRT did not significantly reduce the incidence of all-cause death or intervention for heart failure decompensation in the included population of patients with heart failure, left bundle branch block, and intact AV conduction. Death and heart failure decompensation rates were low with both CRT therapies, suggesting a greater response to CRT occurred in this population than in patients in previous trials. FUNDING: Medtronic.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Masculino , Femenino , Bloqueo de Rama/etiología , Bloqueo de Rama/terapia , Estudios Prospectivos , Resultado del Tratamiento , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Volumen Sistólico , Electrocardiografía
3.
J Cardiovasc Electrophysiol ; 31(6): 1519-1526, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32162753

RESUMEN

BACKGROUND: Atrial fibrillation (AF) and heart failure (HF) often coexist but little is known on how AF burden associates with subsequent episodes of HF. OBJECTIVE: The aim of this study was to quantitatively assess the short- and long-term association of AF burden with subsequent episodes of HF events in patients with reduced ejection fraction. METHODS: Patients with cardiac resynchronization therapy (CRT) devices with at least 90 days of device data were included in the study. Time-dependent Cox regression with a 7-day window was used to evaluate the association of short- and long-term AF burden with subsequent HF events. Each patient with HF was matched to two control patients without an HF event based on age, gender, year of implant and CRT defibrillation capability. RESULTS: In our cohort with 2:1 matching (N = 549), 183 patients developed HF events and 275 (50.1%) had AF over an average follow-up of 24 ± 11 months. A 1-hour increase in short-term AF burden was associated with a 3% increased risk of HF events (HR, 1.034; 95% confidence interval [CI], 1.012-1.056; P = .01; HR for 24-hour = 2.23). In contrast, the association between long-term AF burden and subsequent HF events was not statistically significant (HR, 1.009; 95% CI, 0.992-1.026; P = .373). CONCLUSION: A 24-hour increase in AF burden is associated with a more than two-fold increased risk of HF events over the subsequent week while the long-term AF burden is not significantly associated with HF events.


Asunto(s)
Fibrilación Atrial/epidemiología , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca/epidemiología , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/terapia , Terapia de Resincronización Cardíaca/efectos adversos , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Pronóstico , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Volumen Sistólico , Factores de Tiempo , Función Ventricular Izquierda
4.
J Cardiovasc Electrophysiol ; 30(12): 2877-2884, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31646695

RESUMEN

BACKGROUND: Contemporary implantable cardioverter-defibrillator (ICD) programming involving delayed high-rate detection and use of supraventricular tachycardia (SVT) discriminators has significantly reduced the rate of inappropriate shocks. The extent to which SVT algorithms alone reduce inappropriate therapies is poorly understood. METHODS AND RESULTS: PainFree SST enrolled 2770 patients with a single- or dual-chamber ICD or cardiac resynchronization defibrillator. Patients were followed for 22 ± 9 months with SVT discriminators on in 96% of patients. Sustained ventricular tachyarrhythmias and SVT episodes were adjudicated by an independent physician committee. For this analysis, all episodes were subjected to postprocessing computer simulation with SVT discriminators off with and without delayed high-rate detection criteria (ventricular fibrillation zone only, 30/40 at 320 ms). There were 3282 adjudicated SVT episodes of which 115 resulted in an ICD shock and 113 received only ATP (2-year inappropriate shock and therapy rates of 3.1% and 4.1%). Therapy was appropriately withheld for the remaining 3054 SVT episodes. With both SVT discriminators and delayed high-rate detection simulated off, the 2-year inappropriate therapy rate would have been 22.9% (hazard ratio [HR] = 6.24; 95% confidence interval [CI]: 5.20-7.49). With SVT discriminators simulated off and delayed high-rate detection simulated on in all patients, the 2-year rate would have been 6.4% (HR = 1.63; CI: 1.44-1.85). CONCLUSIONS: The use of SVT discriminators has a significant role in reducing the rate of inappropriate ICD therapy even in the setting of delayed high-rate detection settings. Deactivating SVT discriminators would have resulted in an overall increase in the inappropriate ICD therapy rate by 63% and 524% with and without delayed high-rate detection programming, respectively.


Asunto(s)
Algoritmos , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca/efectos adversos , Desfibriladores Implantables , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/instrumentación , Falla de Prótesis , Procesamiento de Señales Asistido por Computador , Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/terapia , Fibrilación Ventricular/terapia , Anciano , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Taquicardia Supraventricular/fisiopatología , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/fisiopatología
5.
Pacing Clin Electrophysiol ; 42(2): 132-138, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30478983

RESUMEN

BACKGROUND: Atrial arrhythmias are associated with major adverse cardiovascular events. Recent reports among implantable cardioverter defibrillator (ICD) patients have demonstrated a high prevalence of atrial fibrillation (AF), predominantly in dual-chamber recipients. AF incidence among patients with single-chamber systems (approximately 50% of all ICDs) is currently unknown. The objective was to estimate the prevalence of new-onset AF among single-chamber ICD patients by observing the rates of new atrial tachycardia (AT)/AF among a propensity scoring matched cohort of dual-chamber ICD patients from the PainFree SmartShock technology study, to better inform screening initiatives. METHODS: Among 2770 patients enrolled, 1862 single-chamber, dual-chamber, and cardiac resynchronization therapy subjects with no prior history of atrial tachyarrhythmias were included. Daily AT/AF burden was estimated using a propensity score weighted model against data from dual-chamber ICDs. RESULTS: Over 22 ± 9 months of follow-up, the estimated incidence of AT/AF-lasting at least 6 min, 6 h, and 24 h per day -in the single-chamber cohort was 22.0, 9.8, and 6.3%, whereas among dual-chamber patients, the prevalence was 26.6, 13.1, and 7.1%, respectively. Initiation of oral anticoagulation was estimated to occur in 9.8% of the propensity matched single-chamber cohort, which was higher than the actual observed rate of 6.0%. Stroke and transient ischemic attack occurred at low rates in all device subgroups. CONCLUSIONS: Atrial arrhythmias occur frequently, and significant underutilization of anticoagulation is suggested in single-chamber ICD recipients. Routine screening for AF should be considered among single-chamber ICD recipients.


Asunto(s)
Fibrilación Atrial/epidemiología , Desfibriladores Implantables , Complicaciones Posoperatorias/epidemiología , Anciano , Estudios de Cohortes , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Diseño de Prótesis
6.
Europace ; 20(2): e1-e10, 2018 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-28339818

RESUMEN

Aims: Cardiac resynchronization therapy (CRT) reduces morbidity and mortality in systolic heart failure patients with ventricular conduction delay. Variability of individual response to CRT warrants improved patient selection. The Markers and Response to CRT (MARC) study was designed to investigate markers related to response to CRT. Methods and results: We prospectively studied the ability of 11 clinical, 11 electrocardiographic, 4 echocardiographic, and 16 blood biomarkers to predict CRT response in 240 patients. Response was measured by the reduction of indexed left ventricular end-systolic volume (LVESVi) at 6 months follow-up. Biomarkers were related to LVESVi change using log-linear regression on continuous scale. Covariates that were significant univariately were included in a multivariable model. The final model was utilized to compose a response score. Age was 67 ± 10 years, 63% were male, 46% had ischaemic aetiology, LV ejection fraction was 26 ± 8%, LVESVi was 75 ± 31 mL/m2, and QRS was 178 ± 23 ms. At 6 months LVESVi was reduced to 58 ± 31 mL/m2 (relative reduction of 22 ± 24%), 130 patients (61%) showed ≥ 15% LVESVi reduction. In univariate analysis 17 parameters were significantly associated with LVESVi change. In the final model age, QRSAREA (using vectorcardiography) and two echocardiographic markers (interventricular mechanical delay and apical rocking) remained significantly associated with the amount of reverse ventricular remodelling. This CAVIAR (CRT-Age-Vectorcardiographic QRSAREA -Interventricular Mechanical delay-Apical Rocking) response score also predicted clinical outcome assessed by heart failure hospitalizations and all-cause mortality. Conclusions: The CAVIAR response score predicts the amount of reverse remodelling after CRT and may be used to improve patient selection. Clinical Trials: NCT01519908.

7.
Pacing Clin Electrophysiol ; 41(9): 1185-1191, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29928759

RESUMEN

BACKGROUND: The PainFree Smart Shock Technology (SST) study showed a low implantable cardioverter-defibrillator (ICD) inappropriate shock rate. However, the majority of patients were from Western countries with patient characteristics different from those in Japan. ICD shock rates using the novel SST algorithms in Japanese patients are still unknown. METHODS: All 2,770 patients in the PainFree SST study (Japan [JPN]: N = 181, other geographies [OJPN]: N = 2,589) were included in this analysis. RESULTS: Japanese patients had higher average left ventricular ejection fraction (P < 0.0001), higher prevalence of secondary prevention indications (P < 0.0001), nonischemic cardiomyopathy (P < 0.0001), and permanent atrial fibrillation (P < 0.0001). The appropriate shock rate at 12 months was not different between JPN and OJPN: 6.4% and 6.3%, respectively (P = 0.95). The inappropriate shock rate at 12 months was significantly higher in Japanese patients (2.9% vs 1.7%, P = 0.017). However, after propensity score matching to adjust for the difference in baseline characteristics, the difference in inappropriate shock rate was not statistically significant (P = 0.51). CONCLUSIONS: There was no difference in the appropriate shock rate between Japan and other geographies. The inappropriate shock rate in Japan was low, although it was slightly higher compared to other geographies due to baseline characteristics, including a higher prevalence of permanent AF. There was not a statistically significant difference after adjusting for baseline characteristics.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Cardioversión Eléctrica , Anciano , Algoritmos , Desfibriladores Implantables , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Puntaje de Propensión , Estudios Prospectivos
8.
Pacing Clin Electrophysiol ; 40(3): 294-300, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28054365

RESUMEN

BACKGROUND: Central sleep apnea syndrome, correlated with the occurrence of heart failure, is characterized by periods of insufficient ventilation during sleep. This acute study in 15 patients aims to map the venous system and determine if diaphragmatic movement can be achieved by phrenic nerve stimulation at various locations within the venous system. METHODS: Subjects underwent a scheduled catheter ablation procedure. During the procedural waiting time, one multielectrode electrophysiology catheter was subsequently placed at the superior and inferior vena cava and the junctions of the left jugular and left brachiocephalic vein and right jugular and right brachiocephalic vein, for phrenic nerve stimulation (1-2 seconds ON/2-3 seconds OFF, 40 Hz, pulse width 210 µs). Diaphragmatic movement was assessed manually and by a breathing mask. During a follow-up assessment between 2 and 4 weeks postprocedure, occurrence of adverse events was assessed. RESULTS: In all patients diaphragmatic movement was induced at one or more locations using a median threshold of at least 2 V and maximally 7.5 V (i.e., e 3.3 mA, 14.2 mA). The lowest median current to obtain diaphragmatic stimulation without discomfort was found for the right brachiocephalic vein (4.7 mA). In 12/15 patients diaphragmatic movement could be induced without any discomfort, but in three patients hiccups occurred. CONCLUSION: Diaphragmatic stimulation from the brachiocephalic and caval veins is feasible. Potential side effects should be eliminated by adapting the stimulation pattern. This information could be used to design a catheter, combining cardiac pacing with enhancing diaphragm movement during a sleep apnea episode.


Asunto(s)
Cateterismo Periférico/métodos , Diafragma/fisiopatología , Terapia por Estimulación Eléctrica/métodos , Nervio Frénico/fisiopatología , Apnea Central del Sueño/fisiopatología , Apnea Central del Sueño/terapia , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Países Bajos , Apnea Central del Sueño/diagnóstico , Resultado del Tratamiento
9.
Eur Heart J ; 37(41): 3154-3163, 2016 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-26984864

RESUMEN

AIMS: Hospital admissions are frequently preceded by increased pulmonary congestion in heart failure (HF) patients. This study evaluated whether early automated fluid status alert notification via telemedicine improves outcome in HF patients. METHODS AND RESULTS: Patients recently implanted with an implantable cardioverter defibrillator (ICD) with or without cardiac resynchronization therapy were eligible if one of three conditions was met: prior HF hospitalization, recent diuretic treatment, or recent brain natriuretic peptide increase. Eligible patients were randomized (1:1) to have fluid status alerts automatically transmitted as inaudible text message alerts to the responsible physician or to receive standard care (no alerts). In the intervention arm, following a telemedicine alert, a protocol-specified algorithm with remote review of device data and telephone contact was prescribed to assess symptoms and initiate treatment. The primary endpoint was a composite of all-cause death and cardiovascular hospitalization. We followed 1002 patients for an average of 1.9 years. The primary endpoint occurred in 227 patients (45.0%) in the intervention arm and 239 patients (48.1%) in the control arm [hazard ratio, HR, 0.87; 95% confidence interval (CI), 0.72-1.04; P = 0.13]. There were 59 (11.7%) deaths in the intervention arm and 63 (12.7%) in the control arm (HR, 0.89; 95% CI, 0.62-1.28; P = 0.52). Twenty-four per cent of alerts were not transmitted and 30% were followed by a medical intervention. CONCLUSION: Among ICD patients with advanced HF, fluid status telemedicine alerts did not significantly improve outcomes. Adherence to treatment protocols by physicians and patients might be challenge for further developments in the telemedicine field.


Asunto(s)
Insuficiencia Cardíaca , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Hospitalización , Humanos , Telemedicina , Resultado del Tratamiento
10.
Eur Heart J ; 37(27): 2118-27, 2016 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-26787437

RESUMEN

AIMS: The ALternate Site Cardiac ResYNChronization (ALSYNC) study evaluated the feasibility and safety of left ventricular endocardial pacing (LVEP) using a market-released pacing lead implanted via a single pectoral access by a novel atrial transseptal lead delivery system. METHODS AND RESULTS: ALSYNC was a prospective clinical investigation with a minimum of 12-month follow-up in 18 centres of cardiac resynchronization therapy (CRT)-indicated patients, who had failed or were unsuitable for conventional CRT. The ALSYNC system comprises the investigational lead delivery system and LVEP lead. Patients required warfarin therapy post-implant. The primary study objective was safety at 6-month follow-up, which was defined as freedom from complications related to the lead delivery system, implant procedure, or the lead ≥70%. The ALSYNC study enrolled 138 patients. The LVEP lead implant success rate was 89.4%. Freedom from complications meeting the definition of primary endpoint was 82.2% at 6 months (95% CI 75.6-88.8%). In the study, 14 transient ischaemic attacks (9 patients, 6.8%), 5 non-disabling strokes (5 patients, 3.8%), and 23 deaths (17.4%) were observed. No death was from a primary endpoint complication. At 6 months, the New York Heart Association class improved in 59% of patients, and 55% had LV end-systolic volume reduction of 15% or greater. Those patients enrolled after CRT non-response showed similar improvement with LVEP. CONCLUSIONS: The ALSYNC study demonstrates clinical feasibility, and provides an early indication of possible benefit and risk of LVEP. CLINICAL TRIAL: NCT01277783.


Asunto(s)
Ventrículos Cardíacos , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Estudios Prospectivos , Resultado del Tratamiento
11.
ESC Heart Fail ; 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38712903

RESUMEN

AIMS: Clinical pathways have been shown to improve outcomes in patients with heart failure (HF). Although patients with HF often have a cardiac implantable electronic device, few studies have reported the utility of device-derived risk scores to augment and organize care. TriageHF Plus is a device-based HF clinical pathway (DHFP) that uses remote monitoring alerts to trigger structured telephone assessment for HF stability and optimization. We aimed to evaluate the impact of TriageHF Plus on hospitalizations and describe the associated workforce burden. METHODS AND RESULTS: TriageHF Plus was a multi-site, prospective study that compared outcomes for patients recruited between April 2019 and February 2021. All alert-triggered assessments were analysed to determine the appropriateness of the alert and the workload burden. A negative-binomial regression with inverse probability treatment weighting using a time-matched usual care cohort was applied to estimate the effect of TriageHF Plus on non-elective hospitalizations. A post hoc pre-COVID-19 sensitivity analysis was also performed. The TriageHF Plus cohort (n = 443) had a mean age of 68.8 ± 11.2 years, 77% male (usual care cohort: n = 315, mean age of 66.2 ± 14.5 years, 65% male). In the TriageHF Plus cohort, an acute medical issue was identified following an alert in 79/182 (43%) cases. Fifty assessments indicated acute HF, requiring clinical action in 44 cases. At 30 day follow-up, 39/66 (59%) of initially symptomatic patients reported improvement, and 20 (19%) initially asymptomatic patients had developed new symptoms. On average, each assessment took 10 min. The TriageHF Plus group had a 58% lower rate of hospitalizations across full follow-up [incidence relative ratio: 0.42, 95% confidence interval (CI): 0.23-0.76, P = 0.004]. Across the pre-COVID-19 window, hospitalizations were 31% lower (0.69, 95% CI: 0.46-1.04, P = 0.077). CONCLUSIONS: These data represent the largest real-world evaluation of a DHFP based on multi-parametric risk stratification. The TriageHF Plus clinical pathway was associated with an improvement in HF symptoms and reduced all-cause hospitalizations.

12.
Circulation ; 126(7): 822-9, 2012 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-22781424

RESUMEN

BACKGROUND: Cardiac resynchronization therapy (CRT) decreases mortality, improves functional status, and induces reverse left ventricular remodeling in selected populations with heart failure. We aimed to assess the impact of baseline QRS duration and morphology and the change in QRS duration with pacing on CRT outcomes in mild heart failure. METHODS AND RESULTS: Resynchronization Reverses Remodeling in Systolic Left Ventricular Dysfunction (REVERSE) was a multicenter randomized trial of CRT among 610 patients with mild heart failure. Baseline and CRT-paced QRS durations and baseline QRS morphology were evaluated by blinded core laboratories. The mean baseline QRS duration was 151±23 milliseconds, and 60.5% of subjects had left bundle-branch block (LBBB). Patients with LBBB experienced a 25.3-mL/m(2) mean reduction in left ventricular end-systolic volume index (P<0.0001), whereas non-LBBB patients had smaller decreases (6.7 mL/m(2); P=0.18). Baseline QRS duration was also a strong predictor of change in left ventricular end-systolic volume index with monotonic increases as QRS duration prolonged. Similarly, the clinical composite score improved with CRT for LBBB subjects (odds ratio, 0.530; P=0.0034) but not for non-LBBB subjects (odds ratio, 0.724; P=0.21). The association between clinical composite score and QRS duration was highly significant (odds ratio, 0.831 for each 10-millisecond increase in QRS duration; P<0.0001), with improved response at longer QRS durations. The change in QRS duration with CRT pacing was not an independent predictor of any outcomes after correction for baseline variables. CONCLUSION: REVERSE demonstrated that LBBB and QRS prolongation are markers of reverse remodeling and clinical benefit with CRT in mild heart failure. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00271154.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca/terapia , Anciano , Bloqueo de Rama/complicaciones , Electrocardiografía , Femenino , Corazón/fisiopatología , Insuficiencia Cardíaca/etiología , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/complicaciones , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/terapia , Remodelación Ventricular/fisiología
13.
Pacing Clin Electrophysiol ; 36(2): 214-20, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23121136

RESUMEN

INTRODUCTION: Cardiac resynchronization therapy (CRT) can improve clinical and cardiac structural status in heart failure patients. The role of baseline diastolic echocardiographic parameters to characterize the likelihood of positive outcomes is not well known. We explored relationships between diastolic parameters and outcomes 6 months after CRT implant in the Predictors of Response to CRT (PROSPECT) Trial. HYPOTHESIS: We hypothesized that diastolic echocardiographic parameters were associated with clinical and structural outcomes in CRT patients. METHODS: For 426 patients in PROSPECT, a prospective observational trial of CRT, baseline E/A ratio, left atrial (LA) area, isovolumic relaxation time, left ventricular inflow deceleration time, E' velocity, and E/E' ratio were evaluated and related to 6-month clinical composite score (CCS) and left ventricular end-systolic volume (LVESV) reduction using Spearman rank-order correlations. Parameters associated with outcomes were analyzed further by discrete categorization. RESULTS: As continuous variables, only E/A ratio and LA area correlated with CCSs (P = 0.017, P = 0.045, respectively) and relative change in LVESV at 6 months (P < 0.0001, P = 0.001, respectively). As discrete variables, E/A ratio and LA area also correlated with CCSs and LVESV. CONCLUSION: Diastolic echo parameters E/A ratio and LA area were associated with clinical and structural outcomes in CRT patients at 6 months.


Asunto(s)
Ecocardiografía/estadística & datos numéricos , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/prevención & control , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/prevención & control , Anciano , Comorbilidad , Femenino , Humanos , Masculino , Prevalencia , Reproducibilidad de los Resultados , Medición de Riesgo , Factores de Riesgo , Sensibilidad y Especificidad , Estados Unidos/epidemiología
14.
Eur Heart J ; 33(21): 2662-71, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22285578

RESUMEN

OBJECTIVES: The objective of this study is to ascertain the effects of the left (LV) and right (RV) ventricular lead tip position in response to cardiac resynchronization therapy (CRT). BACKGROUND: The REVERSE randomized trial examined the effects of CRT in patients with asymptomatic or mildly symptomatic heart failure (HF). METHODS: We analysed data collected from the active group (CRT-ON) of REVERSE in whom the precise locations of the LV and RV ventricular lead tips were determined from postoperative chest roentgenograms as part of a prespecified sub-study. LV position was classified as lateral or non-lateral, and apical or non-apical. RV position was classified as apical or non-apical. Echocardiographic LV end-systolic volume index (LVESVi), QRS duration, and clinical outcomes at 12-24 months of follow-up were evaluated with respect to the lead tip position. The primary trial endpoint was the proportion of patients with a worsened HF clinical composite response, scored as improved, unchanged, or worsened. RESULTS: Totally 346 patients included in this analysis were followed for a median of 12.6 months (interquartile range: 11.9-23.9 months). The proportion of worsened HF clinical composite response did not correlate with lead position, whereas a significantly greater decrease in the powered secondary endpoint of LVESVi was observed with the non-apical vs. the apical LV lead positions. CRT-paced QRS duration was significantly shorter than at baseline in patients with lateral vs. non-lateral LV position, as well non-apical vs. apical LV position. The incidence of composite endpoint of death and first hospitalization for HF was lower in the LV lateral than in the non-lateral (HR 0.44; 95% CI 0.19-0.99; P= 0.04), and in the LV non-apical than in the apical group (HR 0.27; 95% CI 0.11-0.63; P= 0.001). No significant differences were observed between RV apical and non-apical positions of the lead tip. CONCLUSIONS: A more favourable outcome of CRT with regard to LV reverse remodelling and the composite of time to death or first HF hospitalization was observed when the LV lead tip was implanted in the lateral wall, away from the apex, while the position of the RV lead tip was indifferent. The long-term change in QRS duration was significantly associated with the position of the LV lead tip. ClinicalTrials.gov Identifier: NCT00271154.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca/terapia , Implantación de Prótesis/métodos , Terapia de Resincronización Cardíaca/métodos , Método Doble Ciego , Electrocardiografía , Femenino , Ventrículos Cardíacos , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
15.
Circulation ; 124(16): 1719-26, 2011 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-21931078

RESUMEN

BACKGROUND: Heart failure is associated with frequent hospitalizations, often resulting from volume overload. Measurement of intrathoracic impedance with an implanted device with an audible patient alert may detect increases in pulmonary fluid retention early. We hypothesized that early intervention could prevent hospitalizations and affect outcome. METHODS AND RESULTS: We studied 335 patients with chronic heart failure who had undergone implantation of an implantable cardioverter-defibrillator alone (18%) or with cardiac resynchronization therapy (82%). All devices featured a monitoring tool to track changes in intrathoracic impedance (OptiVol) and other diagnostic parameters. Patients were randomized to have information available to physicians and patients as an audible alert in case of preset threshold crossings (access arm) or not (control arm). The primary end point was a composite of all-cause mortality and heart failure hospitalizations. During 14.9±5.4 months, this occurred in 48 patients (29%) in the access arm and in 33 patients (20%) in the control arm (P=0.063; hazard ratio, 1.52; 95% confidence interval, 0.97-2.37). This was due mainly to more heart failure hospitalizations (hazard ratio, 1.79; 95% confidence interval, 1.08-2.95; P=0.022), whereas the number of deaths was comparable (19 versus 15; P=0.54). The number of outpatient visits was higher in the access arm (250 versus 84; P<0.0001), with relatively more signs of heart failure among control patients during outpatient visits. Although the trial was terminated as a result of slow enrollment, a post hoc futility analysis indicated that a positive result would have been unlikely. CONCLUSION: Use of an implantable diagnostic tool to measure intrathoracic impedance with an audible patient alert did not improve outcome and increased heart failure hospitalizations and outpatient visits in heart failure patients. Clinical Trial Registration-URL: http://www.clinicaltrials.gov. Unique identifier: NCT 00480077.


Asunto(s)
Terapia de Resincronización Cardíaca/normas , Cardiografía de Impedancia/métodos , Desfibriladores Implantables/normas , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Hospitalización/estadística & datos numéricos , Adolescente , Anciano , Terapia de Resincronización Cardíaca/mortalidad , Enfermedad Crónica , Humanos , Persona de Mediana Edad , Resultado del Tratamiento , Adulto Joven
16.
Eur Heart J ; 32(18): 2266-73, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21362703

RESUMEN

AIMS: Early recognition of impending decompensation and timely intervention may prevent heart failure (HF) hospitalization. We investigated the performance of OptiVol® intrathoracic fluid monitoring for the prediction of HF events in chronic HF patients newly implanted with a device (implantable cardioverter-defibrillator with or without cardiac resynchronization therapy). METHODS AND RESULTS: SENSE-HF was a prospective, multi-centre study that enrolled 501 patients. Phase I (double blinded, 6 months) determined the sensitivity and positive predictive value (PPV) of the OptiVol data in predicting HF hospitalizations. Of 58 adjudicated HF hospitalizations that occurred during the first 6 months in Phase I, 12 were predicted by OptiVol (sensitivity = 20.7%). Sensitivity appeared to be dynamic in nature and at the end of Phase I, had increased to 42.1%. With 253 OptiVol detections, PPV for Phase I was 4.7%. Phase II/III (unblinded, 18 months) determined the PPV of the first OptiVol Patient Alert for detection of worsening HF status with signs and/or symptoms of pulmonary congestion. A total of 233 patients noted such an OptiVol alert and for 210, HF status was evaluated within 30 days. Heart failure status had worsened for 80 patients (PPV = 38.1%). CONCLUSIONS: An intrathoracic impedance-derived fluid index had low sensitivity and PPV in the early period after implantation of a device in chronic HF patients. Sensitivity improved within the first 6 months after implant. Further studies are needed to assess the place of this monitoring technology in the clinical management of patients with HF.


Asunto(s)
Cardiografía de Impedancia/instrumentación , Desfibriladores Implantables , Insuficiencia Cardíaca/prevención & control , Anciano , Método Doble Ciego , Diagnóstico Precoz , Electrodos Implantados , Femenino , Hospitalización/estadística & datos numéricos , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Ambulatorio/instrumentación , Sensibilidad y Especificidad
17.
J Arrhythm ; 38(4): 608-614, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35936040

RESUMEN

Aims: The aim of the Mid-Q Response study is to test the hypothesis that adaptive preferential left ventricular-only pacing with the AdaptivCRT algorithm has superior clinical outcomes compared to conventional cardiac resynchronization therapy (CRT) in heart failure (HF) patients with moderately wide QRS duration (≥120 ms and <150 ms), left bundle branch block (LBBB), and normal atrioventricular (AV) conduction (PR interval ≤200 ms). Methods: This prospective, multi-center, randomized, controlled, clinical study is being conducted at approximately 60 centers in Asia. Following enrollment and baseline assessment, eligible patients are implanted with a CRT system equipped with the AdaptivCRT algorithm and are randomly assigned in a 1:1 ratio to have AdaptivCRT ON (Adaptive Bi-V and LV pacing) or AdaptivCRT OFF (Nonadaptive CRT). A minimum of 220 randomized patients are required for analysis of the primary endpoint, clinical composite score (CCS) at 6 months post-implant. The secondary and ancillary endpoints are all-cause and cardiovascular death, hospitalizations for worsening HF, New York Heart Association (NYHA) class, Kansas City Cardiomyopathy Questionnaire (KCCQ), atrial fibrillation (AF), and cardiovascular adverse events at 6 or 12 months. Conclusion: The Mid-Q Response study is expected to provide additional evidence on the incremental benefit of the AdaptivCRT algorithm among Asian HF patients with normal AV conduction, moderately wide QRS, and LBBB undergoing CRT implant.

18.
Int J Cardiol ; 350: 36-40, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-34998948

RESUMEN

BACKGROUND: Patients with inherited arrhythmogenic diseases (IADs) are often prescribed preventative implantable cardioverter-defibrillators (ICDs) to manage their increased sudden cardiac arrest risk. However, it has been suggested that ICDs in IAD patients may come with additional risk. We aimed to leverage the PainFree SmartShock Technology dataset to compare inappropriate therapies, appropriate therapies, mortality, and complications in patients with and without IAD. METHODS: This retrospective analysis included extracted, physician-adjudicated, arrhythmic episodes from ICD devices. The incidence of arrhythmic events was estimated with the Kaplan-Meier method using the log-rank test. Cox proportional hazards regression was used to estimate hazard ratios (HRs) with their 95% confidence intervals (CIs). RESULTS: Of the 1699 ICD patients, 77 patients (4.5%) had IAD. Incidence of inappropriate shock was similar in both patients with (3.2% at 24 months) and without (3.8% at 24 months) IAD (HR: 0.80, CI: 0.19-3.30, p = 0.76). In a multivariable analysis IAD was not significantly associated with reduced mortality (HR: 0.64, CI: 0.08-4.80, p = 0.66). The rates of complications were numerically lower in patients with IAD vs without (8.8% vs 9.6% at 24 months respectively), but not statistically significant (HR: 0.83, CI: 0.20-3.38, p = 0.79). CONCLUSIONS: IAD patients showed a very low annual rate of inappropriate therapy. This suggests that newer algorithms, such as the SST algorithm, are equally good at identifying and treating life-threatening arrhythmias in patients regardless of whether they have IAD.


Asunto(s)
Desfibriladores Implantables , Arritmias Cardíacas/etiología , Muerte Súbita Cardíaca/epidemiología , Desfibriladores Implantables/efectos adversos , Humanos , Estudios Retrospectivos , Factores de Riesgo , Tecnología , Resultado del Tratamiento
19.
Indian Heart J ; 74(3): 194-200, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35490849

RESUMEN

AIMS: Sudden cardiac death (SCD) continues to be a devastating complication amongst survivors of myocardial infarction (MI). Mortality is high in the initial months after MI. The aims of the INSPIRE-ELR study were to assess the proportion of patients with significant arrhythmias early after MI and the association with mortality during 12 months of follow-up. METHODS: The study included 249 patients within 14 days after MI with left ventricular ejection fraction (LVEF) ≤35% at discharge in 11 hospitals in India. Patients received a wearable external loop recorder (ELR) 5 ± 3 days after MI to monitor arrhythmias for 7 days. RESULTS: Patients were predominantly male (86%) with a mean age of 56 ± 12 years. In 82%, reperfusion had been done and all received standard of care cardiovascular medications at discharge. LVEF was 32.2 ± 3.9%, measured 5.1 ± 3.0 days after MI. Of the 233 patients who completed monitoring (7.1 ± 1.5 days), 81 (35%) experienced significant arrhythmias, including Ventricular Tachycardia/Fibrillation (VT/VF): 10 (4.3%); frequent Premature Ventricular Contractions (PVCs): 65 (28%); Atrial Fibrillation (AF): 8 (3.4%); chronic atrial flutter: 4 (1.7%); 2nd or 3rd degree Atrioventricular (AV) block: 4 (1.7%); and symptomatic bradycardia: 8 (3.4%). In total, 26 patients died. Mortality was higher in patients with clinically significant arrhythmia (at 12 months: 23.6% vs 4.8% with 19 vs 7 deaths, hazard ratio (HR) = 5.5, 95% confidence interval (CI) 2.3 to 13.0, p < 0.0001). Excluding 7 deaths during ELR monitoring, HR = 4.5, p < 0.001. CONCLUSION: ELR applied in patients with acute MI and LV dysfunction at the time of discharge identifies patients with high mortality risk.


Asunto(s)
Electrocardiografía Ambulatoria , Infarto del Miocardio , Función Ventricular Izquierda , Adulto , Anciano , Electrocardiografía Ambulatoria/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/mortalidad , Infarto del Miocardio/fisiopatología , Medición de Riesgo/métodos , Función Ventricular Izquierda/fisiología
20.
Circulation ; 121(18): 1985-91, 2010 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-20421518

RESUMEN

BACKGROUND: Numerous criteria believed to define a positive response to cardiac resynchronization therapy have been used in the literature. No study has investigated agreement among these response criteria. We hypothesized that the agreement among the various response criteria would be poor. METHODS AND RESULTS: A literature search was conducted with the keywords "cardiac resynchronization" and "response." The 50 publications with the most citations were reviewed. After the exclusion of editorials and reviews, 17 different primary response criteria were identified from 26 relevant articles. The agreement among 15 of these 17 response criteria was assessed in 426 patients from the Predictors of Response to Cardiac Resynchronization Therapy (PROSPECT) study with Cohen's kappa-coefficient (2 response criteria were not calculable from PROSPECT data). The overall response rate ranged from 32% to 91% for the 15 response criteria. Ninety-nine percent of patients showed a positive response according to at least 1 of the 15 criteria, whereas 94% were classified as a nonresponder by at least 1 criterion. kappa-Values were calculated for all 105 possible comparisons among the 15 response criteria and classified into standard ranges: Poor agreement (kappa< or =0.4), moderate agreement (0.4 or =0.75). Seventy-five percent of the comparisons showed poor agreement, 21% showed moderate agreement, and only 4% showed strong agreement. CONCLUSIONS: The 26 most-cited publications on predicting response to cardiac resynchronization therapy define response using 17 different criteria. Agreement between different methods to define response to cardiac resynchronization therapy is poor 75% of the time and strong only 4% of the time, which severely limits the ability to generalize results over multiple studies.


Asunto(s)
Estimulación Cardíaca Artificial , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Modelos Estadísticos , Evaluación de Resultado en la Atención de Salud/métodos , Insuficiencia Cardíaca/diagnóstico por imagen , Humanos , Valor Predictivo de las Pruebas , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA