Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Am J Respir Crit Care Med ; 205(9): 1036-1045, 2022 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-35104436

RESUMEN

Rationale: Cross-sectional analysis of mucus plugs in computed tomography (CT) lung scans in the Severe Asthma Research Program (SARP)-3 showed a high mucus plug phenotype. Objectives: To determine if mucus plugs are a persistent asthma phenotype and if changes in mucus plugs over time associate with changes in lung function. Methods: In a longitudinal analysis of baseline and Year 3 CT lung scans in SARP-3 participants, radiologists generated mucus plug scores to assess mucus plug persistence over time. Changes in mucus plug score were analyzed in relation to changes in lung function and CT air trapping measures. Measurements and Main Results: In 164 participants, the mean (range) mucus plug score was similar at baseline and Year 3 (3.4 [0-20] vs. 3.8 [0-20]). Participants and bronchopulmonary segments with a baseline plug were more likely to have plugs at Year 3 than those without baseline plugs (risk ratio, 2.8; 95% confidence interval [CI], 2.0-4.1; P < 0.001; and risk ratio, 5.0; 95% CI, 4.5-5.6; P < 0.001, respectively). The change in mucus plug score from baseline to Year 3 was significantly negatively correlated with change in FEV1% predicted (rp = -0.35; P < 0.001) and with changes in CT air trapping measures (all P values < 0.05). Conclusions: Mucus plugs identify a persistent asthma phenotype, and susceptibility to mucus plugs occurs at the subject and the bronchopulmonary segment level. The association between change in mucus plug score and change in airflow over time supports a causal role for mucus plugs in mechanisms of airflow obstruction in asthma.


Asunto(s)
Asma , Moco , Estudios Transversales , Humanos , Pulmón/diagnóstico por imagen , Pruebas de Función Respiratoria
2.
Radiology ; 303(1): 184-190, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34931858

RESUMEN

Background Airway mucus plugs in asthma are associated with exacerbation frequency, increased eosinophilia, and reduced lung function. The relationship between mucus plugs and spatially overlapping ventilation abnormalities observed at hyperpolarized gas MRI has not been assessed quantitatively. Purpose To assess regional associations between CT mucus plugs scored by individual bronchopulmonary segment and corresponding measurements of segmental ventilation defect percentage (VDP) at hyperpolarized helium 3 (3He) MRI. Materials and Methods In this secondary analysis of a Health Insurance Portability and Accountability Act-compliant prospective observational cohort, participants in the Severe Asthma Research Program (SARP) III (NCT01760915) between December 2012 and August 2015 underwent hyperpolarized 3He MRI to determine segmental VDP. Segmental mucus plugs at CT were scored by two readers, with segments scored as plugged only if both readers agreed independently. A linear mixed-effects model controlling for interpatient variability was then used to assess differences in VDP in plugged versus plug-free segments. Results Forty-four participants with asthma were assessed (mean age ± standard deviation, 47 years ± 15; 29 women): 19 with mild-to-moderate asthma and 25 with severe asthma. Mucus plugs were observed in 49 total bronchopulmonary segments across eight of 44 patients. Segments containing mucus plugs had a median segmental VDP of 25.9% (25th-75th percentile, 7.3%-38.3%) versus 1.4% (25th-75th percentile, 0.1%-5.2%; P < .001) in plug-free segments. Similarly, the model estimated a segmental VDP of 18.9% (95% CI: 15.7, 22.2) for mucus-plugged segments versus 5.1% (95% CI: 3.3, 7.0) for plug-free segments (P < .001). Participants with one or more mucus plugs had a median whole-lung VDP of 11.1% (25th-75th percentile, 7.1%-18.9%) versus 3.1% (25th-75th percentile, 1.1%-4.4%) in those without plugs (P < .001). Conclusion Airway mucus plugging at CT was associated with reduced ventilation in the same bronchopulmonary segment at hyperpolarized helium 3 MRI, suggesting that mucus plugging may be an important cause of ventilation defects in asthma. © RSNA, 2021 Online supplemental material is available for this article.


Asunto(s)
Asma , Trastornos Respiratorios , Asma/diagnóstico por imagen , Femenino , Helio , Humanos , Pulmón , Imagen por Resonancia Magnética/métodos , Masculino , Moco/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos
3.
Am J Respir Crit Care Med ; 203(1): 78-89, 2021 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-32673071

RESUMEN

Rationale: Idiopathic pulmonary fibrosis (IPF) is a progressive inflammatory lung disease without effective molecular markers of disease activity or treatment responses. Monocyte and interstitial macrophages that express the C-C motif CCR2 (chemokine receptor 2) are active in IPF and central to fibrosis.Objectives: To phenotype patients with IPF for potential targeted therapy, we developed 64Cu-DOTA-ECL1i, a radiotracer to noninvasively track CCR2+ monocytes and macrophages using positron emission tomography (PET).Methods: CCR2+ cells were investigated in mice with bleomycin- or radiation-induced fibrosis and in human subjects with IPF. The CCR2+ cell populations were localized relative to fibrotic regions in lung tissue and characterized using immunolocalization, single-cell mass cytometry, and Ccr2 RNA in situ hybridization and then correlated with parallel quantitation of lung uptake by 64Cu-DOTA-ECL1i PET.Measurements and Main Results: Mouse models established that increased 64Cu-DOTA-ECL1i PET uptake in the lung correlates with CCR2+ cell infiltration associated with fibrosis (n = 72). As therapeutic models, the inhibition of fibrosis by IL-1ß blockade (n = 19) or antifibrotic pirfenidone (n = 18) reduced CCR2+ macrophage accumulation and uptake of the radiotracer in mouse lungs. In lung tissues from patients with IPF, CCR2+ cells concentrated in perifibrotic regions and correlated with radiotracer localization (n = 21). Human imaging revealed little lung uptake in healthy volunteers (n = 7), whereas subjects with IPF (n = 4) exhibited intensive signals in fibrotic zones.Conclusions: These findings support a role for imaging CCR2+ cells within the fibrogenic niche in IPF to provide a molecular target for personalized therapy and monitoring.Clinical trial registered with www.clinicaltrials.gov (NCT03492762).


Asunto(s)
Biomarcadores/química , Fibrosis Pulmonar Idiopática/fisiopatología , Pulmón/diagnóstico por imagen , Pulmón/fisiopatología , Macrófagos/fisiología , Monocitos/fisiología , Receptores CCR2/química , Adulto , Anciano , Anciano de 80 o más Años , Animales , Modelos Animales de Enfermedad , Femenino , Humanos , Masculino , Ratones , Persona de Mediana Edad , Imagen Molecular , Tomografía de Emisión de Positrones
4.
Am J Respir Crit Care Med ; 203(8): 957-968, 2021 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-33180550

RESUMEN

Rationale: The relative roles of mucus plugs and emphysema in mechanisms of airflow limitation and hypoxemia in smokers with chronic obstructive pulmonary disease (COPD) are uncertain.Objectives: To relate image-based measures of mucus plugs and emphysema to measures of airflow obstruction and oxygenation in patients with COPD.Methods: We analyzed computed tomographic (CT) lung images and lung function in participants in the Subpopulations and Intermediate Outcome Measures in COPD Study. Radiologists scored mucus plugs on CT lung images, and imaging software automatically quantified emphysema percentage. Unadjusted and adjusted relationships between mucus plug score, emphysema percentage, and lung function were determined using regression.Measurements and Main Results: Among 400 smokers, 229 (57%) had mucus plugs and 207 (52%) had emphysema, and subgroups could be identified with mucus-dominant and emphysema-dominant disease. Only 33% of smokers with high mucus plug scores had mucus symptoms. Mucus plug score and emphysema percentage were independently associated with lower values for FEV1 and peripheral oxygen saturation (P < 0.001). The relationships between mucus plug score and lung function outcomes were strongest in smokers with limited emphysema (P < 0.001). Compared with smokers with low mucus plug scores, those with high scores had worse COPD Assessment Test scores (17.4 ± 7.7 vs. 14.4 ± 13.3), more frequent annual exacerbations (0.75 ± 1.1 vs. 0.43 ± 0.85), and shorter 6-minute-walk distance (329 ± 115 vs. 392 ± 117 m) (P < 0.001).Conclusions: Symptomatically silent mucus plugs are highly prevalent in smokers and independently associate with lung function outcomes. These data provide rationale for targeting patients with mucus-high/emphysema-low COPD in clinical trials of mucoactive treatments.Clinical trial registered with www.clinicaltrials.gov (NCT01969344).


Asunto(s)
Hipoxia/inducido químicamente , Hipoxia/fisiopatología , Moco , Enfermedad Pulmonar Obstructiva Crónica/inducido químicamente , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Enfisema Pulmonar/inducido químicamente , Enfisema Pulmonar/fisiopatología , Fumar/efectos adversos , Anciano , Femenino , Volumen Espiratorio Forzado , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Pruebas de Función Respiratoria , Fumadores , Capacidad Vital
5.
Radiology ; 297(3): 675-684, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32930652

RESUMEN

Background Classification of lung cancer screening CT scans depends on measurement of lung nodule size. Information about interobserver agreement is limited. Purpose To assess interobserver agreement in the measurements and American College of Radiology Lung CT Screening Reporting and Data System (Lung-RADS) classifications of solid lung nodules detected at lung cancer screening using manual measurements of average diameter and computer-aided semiautomated measurements of average diameter and volume (CT volumetry). Materials and Methods Two radiologists and one radiology resident retrospectively measured lung nodules from screening CT scans obtained between September 2016 and June 2018 with a Lung-RADS (version 1.0) classification of 2, 3, 4A, or 4B in the clinical setting. Average manual diameter and semiautomated computer-aided diameter and volume measurements were converted to the corresponding Lung-RADS categories. Interobserver agreement in raw measurements was assessed using intraclass correlation and Bland-Altman indexes, and interobserver agreement in Lung-RADS classification was assessed using bi-rater κ. Results One hundred twenty patients (mean age, 63 years ± 6 [standard deviation]; 67 women) were evaluated. All manual, semiautomated diameter, and semiautomated volume measurements were obtained by all three readers in 120 of 147 nodules (82%). Intraclass correlation coefficients were greater than or equal to 0.95 for all reader pairs using all measurement methods and were highest using volumetry. Bias and 95% limits of agreement for average diameter were smaller with semiautomated measurements than with manual measurements. κ values across all Lung-RADS classifications were greater than or equal to 0.81, with the lowest being for manual measurements and the highest being for volumetric measurements. Forty-three of 120 (36%) of the nodules were classified into a lower Lung-RADS category on the basis of volumetry compared with using manual diameter measurements by at least one reader, whereas the reverse occurred for four of 120 (3%) of the nodules. Conclusion Interobserver agreement was high with manual diameter measurements and increased with semiautomated CT volumetric measurements. Semiautomated CT volumetry enabled classification of more nodules into lower Lung CT Screening Reporting and Data System categories than manual or semiautomated diameter measurements. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Nishino in this issue.


Asunto(s)
Neoplasias Pulmonares/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Nódulos Pulmonares Múltiples/diagnóstico por imagen , Variaciones Dependientes del Observador , Estudios Retrospectivos , Nódulo Pulmonar Solitario/diagnóstico por imagen , Carga Tumoral
6.
Radiographics ; 40(1): 28-43, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31782933

RESUMEN

Quantitative analysis of thin-section CT of the chest has a growing role in the clinical evaluation and management of diffuse lung diseases. This heterogeneous group includes diseases with markedly different prognoses and treatment options. Quantitative tools can assist in both accurate diagnosis and longitudinal management by improving characterization and quantification of disease and increasing the reproducibility of disease severity assessment. Furthermore, a quantitative index of disease severity may serve as a useful tool or surrogate endpoint in evaluating treatment efficacy. The authors explore the role of quantitative imaging tools in the evaluation and management of diffuse lung diseases. Lung parenchymal features can be classified with threshold, histogram, morphologic, and texture-analysis-based methods. Quantitative CT analysis has been applied in obstructive, infiltrative, and restrictive pulmonary diseases including emphysema, cystic fibrosis, asthma, idiopathic pulmonary fibrosis, hypersensitivity pneumonitis, connective tissue-related interstitial lung disease, and combined pulmonary fibrosis and emphysema. Some challenges limiting the development and practical application of current quantitative analysis tools include the quality of training data, lack of standard criteria to validate the accuracy of the results, and lack of real-world assessments of the impact on outcomes. Artifacts such as patient motion or metallic beam hardening, variation in inspiratory effort, differences in image acquisition and reconstruction techniques, or inaccurate preprocessing steps such as segmentation of anatomic structures may lead to inaccurate classification. Despite these challenges, as new techniques emerge, quantitative analysis is developing into a viable tool to supplement the traditional visual assessment of diffuse lung diseases and to provide decision support regarding diagnosis, prognosis, and longitudinal evaluation of disease. ©RSNA, 2019.


Asunto(s)
Enfermedades Pulmonares/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Diagnóstico Diferencial , Humanos , Enfermedades Pulmonares/patología , Pronóstico , Pruebas de Función Respiratoria
7.
J Allergy Clin Immunol ; 142(6): 1773-1780.e9, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-29438772

RESUMEN

BACKGROUND: Quantitative computed tomographic (QCT) biomarkers of airway morphology hold potential for understanding and monitoring regional airway remodeling in asthmatic patients. OBJECTIVE: We sought to determine whether the change in airway lumen area between total lung capacity (TLC) and functional residual capacity (FRC) lung volumes measured from CT imaging data was correlated with severe outcomes in asthmatic patients. METHODS: We studied 152 asthmatic patients (90 female and 62 male patients) and 33 healthy subjects (12 female and 21 male subjects) using QCT. Postprocessing of airways at generations 1 to 5 (1 = trachea) was performed for wall area percentage, wall thickness percentage (WT%), lumen area at baseline total lung capacity (LATLC), lumen area at baseline functional residual capacity (LAFRC), and low attenuation area at FRC. A new metric (reflecting remodeling, distal air trapping, or both), Delta Lumen, was determined as follows: Percentage difference in lumen area (LATLC - LAFRC)/LATLC × 100. RESULTS: Postprocessing of 4501 airway segments was performed (3681 segments in the 152 patients with asthma and 820 segments in the 33 healthy subjects; range, 17-28 segments per subject). Delta Lumen values were negatively correlated with WT% and low attenuation area (P < .01) in asthmatic patients. Delta Lumen values were significantly lower for airway generations 3 to 5 (segmental airways) in subjects undergoing hospitalization because of exacerbation and in patients with refractory asthma requiring treatment with systemic corticosteroids. WT% and low attenuation area were positively and Delta Lumen values were negatively associated with systemic corticosteroid treatment (P < .05), suggesting that a reduced Delta Lumen value is a potential outcome biomarker in patients with severe asthma. CONCLUSION: Reduced Delta Lumen value in the central airways measured by using QCT is a promising exploratory biomarker of unstable refractory asthma that warrants further study.


Asunto(s)
Asma/diagnóstico por imagen , Sistema Respiratorio/diagnóstico por imagen , Corticoesteroides/uso terapéutico , Adulto , Remodelación de las Vías Aéreas (Respiratorias) , Asma/tratamiento farmacológico , Asma/patología , Asma/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector , Respiración , Pruebas de Función Respiratoria , Sistema Respiratorio/patología , Sistema Respiratorio/fisiopatología , Adulto Joven
8.
J Allergy Clin Immunol ; 139(1): 1-10, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-28065276

RESUMEN

There have been significant advancements in the various imaging techniques being used for the evaluation of asthmatic patients, both from a clinical and research perspective. Imaging characteristics can be used to identify specific asthmatic phenotypes and provide a more detailed understanding of endotypes contributing to the pathophysiology of the disease. Computed tomography, magnetic resonance imaging, and positron emission tomography can be used to assess pulmonary structure and function. It has been shown that specific airway and lung density measurements using computed tomography correlate with clinical parameters, including severity of disease and pathology, but also provide unique phenotypes. Hyperpolarized 129Xe and 3He are gases used as contrast media for magnetic resonance imaging that provide measurement of distal lung ventilation reflecting small-airway disease. Positron emission tomography can be useful to identify and target lung inflammation in asthmatic patients. Furthermore, imaging techniques can serve as a potential biomarker and be used to assess response to therapies, including newer biological treatments and bronchial thermoplasty.


Asunto(s)
Asma/diagnóstico por imagen , Asma/patología , Biomarcadores , Humanos , Pulmón/patología , Imagen por Resonancia Magnética , Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X
9.
Eur Radiol ; 27(12): 5113-5118, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28616728

RESUMEN

PURPOSE: The National Lung Screening Trial (NLST) demonstrated a reduction in lung cancer and all-cause mortality with low-dose CT (LDCT) screening. The aim of our study was to examine the time to diagnosis (TTD) of lung cancer in the LDCT arm of the NLST and assess its relationship with cancer characteristics and survival. METHODS: The subjects (N = 462) with a positive baseline screen and subsequent lung cancer diagnosis within 3 years were evaluated by data and image review to confirm the baseline abnormality. The cases were analysed for the relationship between TTD and imaging features, cancer type, stage and survival for 7 years from baseline screen. RESULTS: Cancer was judged to be present at baseline in 397/462 cases. The factors that showed significant association (p value trend less than 0.05) with longer TTD included smaller nodule size, pure ground glass nodules (GGNs), smooth/lobulated margins, stages I/II, adenocarcinoma, and decreasing lung cancer mortality. The logistic regression model for lung cancer death showed significant inverse relationships with size less than 20 mm (OR = 0.32), pure GGNs (OR = 0.24), adenocarcinoma (OR = 0.57) and direct relationship with age (OR = 1.4). CONCLUSION: TTD after a positive LDCT screen in the NLST showed a strong association with imaging features, stage and mortality. KEY POINTS: • NLST observed variable time to lung cancer diagnosis from positive baseline screen. • Time to diagnosis was associated with imaging features, cancer type and stage. • In univariate but not multivariate analysis, longer TTD correlated with decreased mortality.


Asunto(s)
Adenocarcinoma/diagnóstico por imagen , Detección Precoz del Cáncer/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Tamizaje Masivo/métodos , Tomografía Computarizada por Rayos X/métodos , Adenocarcinoma/mortalidad , Adenocarcinoma/patología , Anciano , Femenino , Humanos , Modelos Logísticos , Neoplasias Pulmonares/mortalidad , Neoplasias Pulmonares/patología , Masculino , Persona de Mediana Edad
10.
Eur Radiol ; 27(8): 3249-3256, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28050695

RESUMEN

OBJECTIVES: This study retrospectively analyses the screening CT examinations and outcomes of the National Lung Screening Trial (NLST) participants who had interval lung cancer diagnosed within 1 year after a negative CT screen and before the next annual screen. METHODS: The screening CTs of all 44 participants diagnosed with interval lung cancer (cases) were matched with negative CT screens of participants who did not develop lung cancer (controls). A majority consensus process was used to classify each CT screen as positive or negative according to the NLST criteria and to estimate the likelihood that any abnormalities detected retrospectively were due to lung cancer. RESULTS: By retrospective review, 40/44 cases (91%) and 17/44 controls (39%) met the NLST criteria for a positive screen (P < 0.001). Cases had higher estimated likelihood of lung cancer (P < 0.001). Abnormalities included pulmonary nodules ≥4 mm (n = 16), mediastinal (n = 8) and hilar (n = 6) masses, and bronchial lesions (n = 6). Cancers were stage III or IV at diagnosis in 32/44 cases (73%); 37/44 patients (84%) died of lung cancer, compared to 225/649 (35%) for all screen-detected cancers (P < 0.0001). CONCLUSION: Most cases met the NLST criteria for a positive screen. Awareness of missed abnormalities and interpretation errors may aid lung cancer identification in CT screening. KEY POINTS: • Lung cancer within a year of a negative CT screen was rare. • Abnormalities likely due to lung cancer were identified retrospectively in most patients. • Awareness of error types may help identify lung cancer sooner.


Asunto(s)
Detección Precoz del Cáncer/normas , Neoplasias Pulmonares/diagnóstico por imagen , Tamizaje Masivo/normas , Tomografía Computarizada por Rayos X , Anciano , Errores Diagnósticos/prevención & control , Femenino , Humanos , Masculino , Persona de Mediana Edad , Nódulos Pulmonares Múltiples/diagnóstico por imagen , Estudios Retrospectivos
12.
AJR Am J Roentgenol ; 209(5): 1009-1014, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28898131

RESUMEN

OBJECTIVE: As low-dose CT (LDCT) lung cancer screening moves into routine clinical practice, evaluation of nodules identified as new becomes critical. We examine the frequency and clinical outcomes of new lung nodules reported at the two postbaseline annual screening examinations (hereafter referred to as postbaseline time 1 [T1] and time 2 [T2]), compared with those detected at baseline in the National Lung Screening Trial. MATERIALS AND METHODS: Radiologists classified nodules detected at T1 and T2 as new or preexisting on the basis of comparison with findings from prior LDCT screening examinations. Subjects were tracked for lung cancer incidence and mortality. We examined the incidence of new nodules and their associated lung cancer risk by nodule size (i.e., mean diameter). RESULTS: A total of 25,002 subjects underwent the baseline LDCT screening examination and either a T1 or T2 LDCT screen. At both T1 and T2, 2.6% of subjects had new solid nodules. Of the new solid nodules, 53.0% were < 6 mm, 29.5% were 6 to < 10 mm, and 17.1% were ≥ 10 mm. Lung cancer risk (defined as diagnosis within 2 years of baseline) increased from 1.1% for nodules < 4 mm to 24.0% for those ≥ 20 mm. Compared with solid nodules detected at baseline, the cancer risk was higher for new solid nodules that were 4 to < 6 mm (p < 0.001) and 6 to < 8 mm (p < 0.001) but lower for new nodules ≥ 20 mm (p = 0.03). Cancers associated with new nodules had significantly poorer survival than did those associated with baseline nodules and were significantly less likely to be adenocarcinoma. CONCLUSION: The incidence of new nodules was 2-3% annually, with the cancer risk increasing by nodule size. New nodules may convey differential lung cancer risks by size, compared with baseline nodules.


Asunto(s)
Adenocarcinoma/diagnóstico por imagen , Adenocarcinoma/etiología , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/etiología , Nódulo Pulmonar Solitario/diagnóstico por imagen , Adenocarcinoma/mortalidad , Anciano , Detección Precoz del Cáncer , Femenino , Humanos , Incidencia , Neoplasias Pulmonares/mortalidad , Masculino , Tamizaje Masivo , Persona de Mediana Edad , Factores de Riesgo , Nódulo Pulmonar Solitario/complicaciones , Nódulo Pulmonar Solitario/patología , Tasa de Supervivencia , Factores de Tiempo
13.
Pediatr Transplant ; 21(3)2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28120553

RESUMEN

Obtaining information on transplanted lung microstructure is an important part of the current care for monitoring transplant recipients. However, until now this information was only available from invasive lung biopsy. The objective of this study was to evaluate the use of an innovative non-invasive technique, in vivo lung morphometry with hyperpolarized ³He MRI-to characterize lung microstructure in the pediatric lung transplant population. This technique yields quantitative measurements of acinar airways' (alveolar ducts and sacs) parameters, such as acinar airway radii and alveolar depth. Six pediatric lung transplant recipients with cystic fibrosis underwent in vivo lung morphometry MRI, pulmonary function testing, and quantitative CT. We found a strong correlation between lung lifespan and alveolar depth-patients with more shallow alveoli were likely to have a negative outcome sooner than those with larger alveolar depth. Combining morphometric results with CT, we also determined mean alveolar wall thickness and found substantial increases in this parameter in some patients that negatively correlated with DLCO. In vivo lung morphometry uniquely provides previously unavailable information on lung microstructure that may be predictive of a negative outcome and has a potential to aid in lung selection for transplantation.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Trasplante de Pulmón , Pulmón/diagnóstico por imagen , Pulmón/fisiología , Adolescente , Niño , Fibrosis Quística/diagnóstico por imagen , Fibrosis Quística/cirugía , Femenino , Helio/química , Humanos , Masculino , Permeabilidad , Estudios Prospectivos , Alveolos Pulmonares/patología , Pruebas de Función Respiratoria , Relación Señal-Ruido , Tomografía Computarizada por Rayos X , Adulto Joven
14.
N Engl J Med ; 368(21): 1980-91, 2013 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-23697514

RESUMEN

BACKGROUND: Lung cancer is the largest contributor to mortality from cancer. The National Lung Screening Trial (NLST) showed that screening with low-dose helical computed tomography (CT) rather than with chest radiography reduced mortality from lung cancer. We describe the screening, diagnosis, and limited treatment results from the initial round of screening in the NLST to inform and improve lung-cancer-screening programs. METHODS: At 33 U.S. centers, from August 2002 through April 2004, we enrolled asymptomatic participants, 55 to 74 years of age, with a history of at least 30 pack-years of smoking. The participants were randomly assigned to undergo annual screening, with the use of either low-dose CT or chest radiography, for 3 years. Nodules or other suspicious findings were classified as positive results. This article reports findings from the initial screening examination. RESULTS: A total of 53,439 eligible participants were randomly assigned to a study group (26,715 to low-dose CT and 26,724 to chest radiography); 26,309 participants (98.5%) and 26,035 (97.4%), respectively, underwent screening. A total of 7191 participants (27.3%) in the low-dose CT group and 2387 (9.2%) in the radiography group had a positive screening result; in the respective groups, 6369 participants (90.4%) and 2176 (92.7%) had at least one follow-up diagnostic procedure, including imaging in 5717 (81.1%) and 2010 (85.6%) and surgery in 297 (4.2%) and 121 (5.2%). Lung cancer was diagnosed in 292 participants (1.1%) in the low-dose CT group versus 190 (0.7%) in the radiography group (stage 1 in 158 vs. 70 participants and stage IIB to IV in 120 vs. 112). Sensitivity and specificity were 93.8% and 73.4% for low-dose CT and 73.5% and 91.3% for chest radiography, respectively. CONCLUSIONS: The NLST initial screening results are consistent with the existing literature on screening by means of low-dose CT and chest radiography, suggesting that a reduction in mortality from lung cancer is achievable at U.S. screening centers that have staff experienced in chest CT. (Funded by the National Cancer Institute; NLST ClinicalTrials.gov number, NCT00047385.).


Asunto(s)
Detección Precoz del Cáncer/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Radiografía Torácica , Tomografía Computarizada por Rayos X , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dosis de Radiación , Sensibilidad y Especificidad , Fumar , Tomografía Computarizada por Rayos X/métodos
15.
N Engl J Med ; 369(10): 920-31, 2013 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-24004119

RESUMEN

BACKGROUND: The National Lung Screening Trial was conducted to determine whether three annual screenings (rounds T0, T1, and T2) with low-dose helical computed tomography (CT), as compared with chest radiography, could reduce mortality from lung cancer. We present detailed findings from the first two incidence screenings (rounds T1 and T2). METHODS: We evaluated the rate of adherence of the participants to the screening protocol, the results of screening and downstream diagnostic tests, features of the lung-cancer cases, and first-line treatments, and we estimated the performance characteristics of both screening methods. RESULTS: At the T1 and T2 rounds, positive screening results were observed in 27.9% and 16.8% of participants in the low-dose CT group and in 6.2% and 5.0% of participants in the radiography group, respectively. In the low-dose CT group, the sensitivity was 94.4%, the specificity was 72.6%, the positive predictive value was 2.4%, and the negative predictive value was 99.9% at T1; at T2, the positive predictive value increased to 5.2%. In the radiography group, the sensitivity was 59.6%, the specificity was 94.1%, the positive predictive value was 4.4%, and the negative predictive value was 99.8% at T1; both the sensitivity and the positive predictive value increased at T2. Among lung cancers of known stage, 87 (47.5%) were stage IA and 57 (31.1%) were stage III or IV in the low-dose CT group at T1; in the radiography group, 31 (23.5%) were stage IA and 78 (59.1%) were stage III or IV at T1. These differences in stage distribution between groups persisted at T2. CONCLUSIONS: Low-dose CT was more sensitive in detecting early-stage lung cancers, but its measured positive predictive value was lower than that of radiography. As compared with radiography, the two annual incidence screenings with low-dose CT resulted in a decrease in the number of advanced-stage cancers diagnosed and an increase in the number of early-stage lung cancers diagnosed. (Funded by the National Cancer Institute; NLST ClinicalTrials.gov number, NCT00047385.).


Asunto(s)
Neoplasias Pulmonares/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Nódulo Pulmonar Solitario/diagnóstico por imagen , Detección Precoz del Cáncer/métodos , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Nódulos Pulmonares Múltiples/diagnóstico por imagen , Valor Predictivo de las Pruebas , Radiografía Torácica , Sensibilidad y Especificidad , Tomografía Computarizada Espiral
16.
J Comput Assist Tomogr ; 40(4): 589-95, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27096403

RESUMEN

OBJECTIVE: The aim of this study was to compare the performance of 2- (2D) and 3-dimensional (3D) quantitative computed tomography (CT) methods for classifying lung nodules as lung cancer, metastases, or benign. METHODS: Using semiautomated software and computerized analysis, we analyzed more than 50 quantitative CT features of 96 solid nodules in 94 patients, in 2D from a single slice and in 3D from the entire nodule volume. Multivariable logistic regression was used to classify nodule types. Model performance was assessed by the area under the receiver operating characteristic curve (AUC) using leave-one-out cross-validation. RESULTS: The AUC for distinguishing 53 primary lung cancers from 18 benign nodules and 25 metastases ranged from 0.79 to 0.83 and was not significantly different for 2D and 3D analyses (P = 0.29-0.78). Models distinguishing metastases from benign nodules were statistically significant only by 3D analysis (AUC = 0.84). CONCLUSIONS: Three-dimensional CT methods did not improve discrimination of lung cancer, but may help distinguish benign nodules from metastases.


Asunto(s)
Imagenología Tridimensional/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Nódulo Pulmonar Solitario/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Anciano , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Carga Tumoral
17.
Ann Intern Med ; 162(7): 485-91, 2015 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-25664444

RESUMEN

BACKGROUND: Lung cancer screening with low-dose computed tomography (LDCT) has been recommended, based primarily on the results of the NLST (National Lung Screening Trial). The American College of Radiology recently released Lung-RADS, a classification system for LDCT lung cancer screening. OBJECTIVE: To retrospectively apply the Lung-RADS criteria to the NLST. DESIGN: Secondary analysis of a group from a randomized trial. SETTING: 33 U.S. screening centers. PATIENTS: Participants were randomly assigned to the LDCT group of the NLST, were aged 55 to 74 years, had at least a 30-pack-year history of smoking, and were current smokers or had quit within the past 15 years. INTERVENTION: 3 annual LDCT lung cancer screenings. MEASUREMENTS: Lung-RADS classifications for LDCT screenings. Lung-RADS categories 1 to 2 constitute negative screening results, and categories 3 to 4 constitute positive results. RESULTS: Of 26 722 LDCT group participants, 26 455 received a baseline screening; 48 671 screenings were done after baseline. At baseline, the false-positive result rate (1 minus the specificity rate) for Lung-RADS was 12.8% (95% CI, 12.4% to 13.2%) versus 26.6% (CI, 26.1% to 27.1%) for the NLST; after baseline, the false-positive result rate was 5.3% (CI, 5.1% to 5.5%) for Lung-RADS versus 21.8% (CI, 21.4% to 22.2%) for the NLST. Baseline sensitivity was 84.9% (CI, 80.8% to 89.0%) for Lung-RADS versus 93.5% (CI, 90.7% to 96.3%) for the NLST, and sensitivity after baseline was 78.6% (CI, 74.6% to 82.6%) for Lung-RADS versus 93.8% (CI, 91.4% to 96.1%) for the NLST. LIMITATION: Lung-RADS criteria were applied retrospectively. CONCLUSION: Lung-RADS may substantially reduce the false-positive result rate; however, sensitivity is also decreased. The effect of using Lung-RADS criteria in clinical practice must be carefully studied. PRIMARY FUNDING SOURCE: National Institutes of Health.


Asunto(s)
Detección Precoz del Cáncer/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Tamizaje Masivo/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Reacciones Falso Positivas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Dosis de Radiación , Estudios Retrospectivos
18.
J Comput Assist Tomogr ; 39(4): 584-90, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25938213

RESUMEN

OBJECTIVE: We reduced the computed tomography (CT)-reconstructed field of view (FOV), increasing pixel density across airway structures and reducing partial volume effects, to determine whether this would improve accuracy of airway wall thickness quantification. METHODS: We performed CT imaging on a lung phantom and 29 participants. Images were reconstructed at 30-, 15-, and 10-cm FOV using a medium-smooth kernel. Cross-sectional airway dimensions were compared at each FOV with repeated-measures analysis of variance. RESULTS: Phantom measurements were more accurate when FOV decreased from 30 to 15 cm (P < 0.05). Decreasing FOV further to 10 cm did not significantly improve accuracy. Human airway measurements similarly decreased by decreasing FOV (P < 0.001). Percent changes in all measurements when reducing FOV from 30 to 15 cm were less than 3%. CONCLUSIONS: Airway measurements at 30-cm FOV are near the limits of CT resolution using a medium-smooth kernel. Reducing reconstructed FOV would minimally increase sensitivity to detect differences in airway dimensions.


Asunto(s)
Asma/diagnóstico por imagen , Asma/fisiopatología , Procesamiento de Imagen Asistido por Computador/métodos , Pulmón/diagnóstico por imagen , Pulmón/fisiopatología , Tomografía Computarizada Multidetector , Adulto , Análisis de Varianza , Pesos y Medidas Corporales/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
19.
Ann Intern Med ; 161(9): 627-33, 2014 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-25199624

RESUMEN

BACKGROUND: The NLST (National Lung Screening Trial) showed reduced lung cancer mortality in high-risk participants (smoking history of ≥30 pack-years) aged 55 to 74 years who were randomly assigned to screening with low-dose computed tomography (LDCT) versus those assigned to chest radiography. An advisory panel recently expressed reservations about Medicare coverage of LDCT screening because of concerns about performance in the Medicare-aged population, which accounted for only 25% of the NLST participants. OBJECTIVE: To examine the results of the NLST LDCT group by age (Medicare-eligible vs. <65 years). DESIGN: Secondary analysis of a group from a randomized trial (NCT00047385). SETTING: 33 U.S. screening centers. PATIENTS: 19 612 participants aged 55 to 64 years (under-65 cohort) and 7110 participants aged 65 to 74 years (65+ cohort) at randomization. INTERVENTION: 3 annual rounds of LDCT screening. MEASUREMENTS: Demographics, smoking and medical history, screening examination adherence and results, diagnostic follow-up procedures and complications, lung cancer diagnoses, treatment, survival, and mortality. RESULTS: The aggregate false-positive rate was higher in the 65+ cohort than in the under-65 cohort (27.7% vs. 22.0%; P < 0.001). Invasive diagnostic procedures after false-positive screening results were modestly more frequent in the older cohort (3.3% vs. 2.7%; P = 0.039). Complications from invasive procedures were low in both groups (9.8% in the under-65 cohort vs. 8.5% in the 65+ cohort). Prevalence and positive predictive value (PPV) were higher in the 65+ cohort (PPV, 4.9% vs. 3.0%). Resection rates for screen-detected cancer were similar (75.6% in the under-65 cohort vs. 73.2% in the 65+ cohort). Five-year all-cause survival was lower in the 65+ cohort (55.1% vs. 64.1%; P = 0.018). LIMITATION: The oldest screened patient was aged 76 years. CONCLUSION: NLST participants aged 65 years or older had a higher rate of false-positive screening results than those younger than 65 years but a higher cancer prevalence and PPV. Screen-detected cancer was treated similarly in the groups. PRIMARY FUNDING SOURCE: National Institutes of Health.


Asunto(s)
Detección Precoz del Cáncer , Neoplasias Pulmonares/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Factores de Edad , Anciano , Reacciones Falso Positivas , Humanos , Neoplasias Pulmonares/mortalidad , Neoplasias Pulmonares/cirugía , Persona de Mediana Edad , Estadificación de Neoplasias , Neumonectomía , Fumar , Análisis de Supervivencia , Tomografía Computarizada por Rayos X
20.
Nat Commun ; 15(1): 3900, 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38724552

RESUMEN

By incompletely understood mechanisms, type 2 (T2) inflammation present in the airways of severe asthmatics drives the formation of pathologic mucus which leads to airway mucus plugging. Here we investigate the molecular role and clinical significance of intelectin-1 (ITLN-1) in the development of pathologic airway mucus in asthma. Through analyses of human airway epithelial cells we find that ITLN1 gene expression is highly induced by interleukin-13 (IL-13) in a subset of metaplastic MUC5AC+ mucus secretory cells, and that ITLN-1 protein is a secreted component of IL-13-induced mucus. Additionally, we find ITLN-1 protein binds the C-terminus of the MUC5AC mucin and that its deletion in airway epithelial cells partially reverses IL-13-induced mucostasis. Through analysis of nasal airway epithelial brushings, we find that ITLN1 is highly expressed in T2-high asthmatics, when compared to T2-low children. Furthermore, we demonstrate that both ITLN-1 gene expression and protein levels are significantly reduced by a common genetic variant that is associated with protection from the formation of mucus plugs in T2-high asthma. This work identifies an important biomarker and targetable pathways for the treatment of mucus obstruction in asthma.


Asunto(s)
Asma , Proteínas Ligadas a GPI , Interleucina-13 , Lectinas , Mucina 5AC , Moco , Niño , Humanos , Asma/genética , Asma/metabolismo , Citocinas , Células Epiteliales/metabolismo , Proteínas Ligadas a GPI/genética , Proteínas Ligadas a GPI/metabolismo , Interleucina-13/genética , Interleucina-13/metabolismo , Lectinas/genética , Lectinas/metabolismo , Mucina 5AC/genética , Mucina 5AC/metabolismo , Moco/metabolismo , Mucosa Nasal/metabolismo , Polimorfismo Genético , Mucosa Respiratoria/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA