Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Radiology ; 310(1): e230453, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38259204

RESUMEN

Background Splenic biopsy is rarely performed because of the perceived risk of hemorrhagic complications. Purpose To evaluate the safety of large bore (≥18 gauge) image-guided splenic biopsy. Materials and Methods This retrospective study included consecutive adult patients who underwent US- or CT-guided splenic biopsy between March 2001 and March 2022 at eight academic institutions in the United States. Biopsies were performed with needles that were 18 gauge or larger, with a comparison group of biopsies with needles smaller than 18 gauge. The primary outcome was significant bleeding after the procedure, defined by the presence of bleeding at CT performed within 30 days or angiography and/or surgery performed to manage the bleeding. Categorical variables were compared using the χ2 test and medians were compared using the Mann-Whitney test. Results A total of 239 patients (median age, 63 years; IQR, 50-71 years; 116 of 239 [48.5%] female patients) underwent splenic biopsy with an 18-gauge or smaller needle and 139 patients (median age, 58 years [IQR, 49-69 years]; 66 of 139 [47.5%] female patients) underwent biopsy with a needle larger than 18 gauge. Bleeding was detected in 20 of 239 (8.4%) patients in the 18-gauge or smaller group and 11 of 139 (7.9%) in the larger than 18-gauge group. Bleeding was treated in five of 239 (2.1%) patients in the 18-gauge or smaller group and one of 139 (1%) in the larger than 18-gauge group. No deaths related to the biopsy procedure were recorded during the study period. Patients with bleeding after biopsy had smaller lesions compared with patients without bleeding (median, 2.1 cm [IQR, 1.6-5.4 cm] vs 3.5 cm [IQR, 2-6.8 cm], respectively; P = .03). Patients with a history of lymphoma or leukemia showed a lower incidence of bleeding than patients without this history (three of 90 [3%] vs 28 of 288 [9.7%], respectively; P = .05). Conclusion Bleeding after splenic biopsy with a needle 18 gauge or larger was similar to biopsy with a needle smaller than 18 gauge and seen in 8% of procedures overall, with 2% overall requiring treatment. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Grant in this issue.


Asunto(s)
Biopsia Guiada por Imagen , Agujas , Bazo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Angiografía , Biopsia Guiada por Imagen/efectos adversos , Agujas/efectos adversos , Agujas/estadística & datos numéricos , Estudios Retrospectivos , Bazo/diagnóstico por imagen , Bazo/patología , Anciano
2.
Radiology ; 306(2): e220101, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36125375

RESUMEN

Background Adrenal masses are common, but radiology reporting and recommendations for management can be variable. Purpose To create a machine learning algorithm to segment adrenal glands on contrast-enhanced CT images and classify glands as normal or mass-containing and to assess algorithm performance. Materials and Methods This retrospective study included two groups of contrast-enhanced abdominal CT examinations (development data set and secondary test set). Adrenal glands in the development data set were manually segmented by radiologists. Images in both the development data set and the secondary test set were manually classified as normal or mass-containing. Deep learning segmentation and classification models were trained on the development data set and evaluated on both data sets. Segmentation performance was evaluated with use of the Dice similarity coefficient (DSC), and classification performance with use of sensitivity and specificity. Results The development data set contained 274 CT examinations (251 patients; median age, 61 years; 133 women), and the secondary test set contained 991 CT examinations (991 patients; median age, 62 years; 578 women). The median model DSC on the development test set was 0.80 (IQR, 0.78-0.89) for normal glands and 0.84 (IQR, 0.79-0.90) for adrenal masses. On the development reader set, the median interreader DSC was 0.89 (IQR, 0.78-0.93) for normal glands and 0.89 (IQR, 0.85-0.97) for adrenal masses. Interreader DSC for radiologist manual segmentation did not differ from automated machine segmentation (P = .35). On the development test set, the model had a classification sensitivity of 83% (95% CI: 55, 95) and specificity of 89% (95% CI: 75, 96). On the secondary test set, the model had a classification sensitivity of 69% (95% CI: 58, 79) and specificity of 91% (95% CI: 90, 92). Conclusion A two-stage machine learning pipeline was able to segment the adrenal glands and differentiate normal adrenal glands from those containing masses. © RSNA, 2022 Online supplemental material is available for this article.


Asunto(s)
Aprendizaje Automático , Tomografía Computarizada por Rayos X , Humanos , Femenino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X/métodos , Estudios Retrospectivos , Algoritmos , Glándulas Suprarrenales
3.
AJR Am J Roentgenol ; 220(5): 693-704, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36416399

RESUMEN

BACKGROUND. Adrenal masses are often indeterminate on single-phase postcontrast CT. Dual-energy CT (DECT) with three-material decomposition algorithms may aid characterization. OBJECTIVE. The purpose of this study was to compare the diagnostic performance of metrics derived from portal venous phase DECT, including virtual noncontrast (VNC) attenuation, fat fraction, iodine density, and relative enhancement ratio, for characterizing adrenal masses. METHODS. This retrospective study included 128 patients (82 women, 46 men; mean age, 64.6 ± 12.7 [SD] years) who between January 2016 and December 2019 underwent portal venous phase abdominopelvic DECT that showed a total of 139 adrenal lesions with an available reference standard based on all imaging, clinical, and pathologic records (87 adenomas, 52 nonadenomas [48 metastases, two adrenal cortical carcinomas, one ganglioneuroma, one hematoma]). Two radiologists placed ROIs to determine the following characteristics of the masses: VNC attenuation, fat fraction, iodine density normalized to portal vein, and for masses with VNC greater than 10 HU, relative enhancement ratio (ratio of portal venous phase attenuation to VNC attenuation). Readers' mean measurements were used for ROC analyses, and clinically optimal thresholds were derived as thresholds yielding the highest sensitivity at 100% specificity. RESULTS. Adenomas and nonadenomas were significantly different (all p < .001) in VNC attenuation (mean ± SD, 18.5 ± 12.9 vs 34.1 ± 8.9 HU), fat fraction (mean ± SD, 24.3% ± 8.2% vs 14.2% ± 5.6%), normalized iodine density (mean ± SD, 0.34 ± 0.15 vs 0.17 ± 0.17), and relative enhancement ratio (mean ± SD, 186% ± 96% vs 58% ± 59%). AUCs for all metrics ranged from 0.81 through 0.91. The metric with highest sensitivity for adenoma at the clinically optimal threshold (i.e., 100% specificity) was fat fraction (threshold, ≥ 23.8%; sensitivity, 59% [95% CI, 48-69%]) followed by VNC attenuation (≤ 15.2 HU; sensitivity, 39% [95% CI, 29-50%]), relative enhancement ratio (≥ 214%; sensitivity, 37% [95% CI, 25-50%]), and normalized iodine density (≥ 0.90; sensitivity, 1% (95% CI, 0-60%]). VNC attenuation at the traditional true noncontrast attenuation threshold of 10 HU or lower had sensitivity of 28% (95% CI, 19-38%) and 100% specificity. Presence of fat fraction 23.8% or greater or relative enhancement ratio 214% or greater yielded sensitivity of 68% (95% CI, 57-77%) with 100% specificity. CONCLUSION. For adrenal lesions evaluated with single-phase DECT, fat fraction had higher sensitivity than VNC attenuation at both the clinically optimal threshold and the traditional threshold of 10 HU or lower. CLINICAL IMPACT. By helping to definitively diagnose adenomas, DECT-derived metrics can help avoid downstream imaging for incidental adrenal lesions.


Asunto(s)
Adenoma , Neoplasias de la Corteza Suprarrenal , Enfermedades de las Glándulas Suprarrenales , Neoplasias de las Glándulas Suprarrenales , Adenoma Corticosuprarrenal , Yodo , Masculino , Humanos , Femenino , Persona de Mediana Edad , Anciano , Tomografía Computarizada por Rayos X/métodos , Estudios Retrospectivos , Benchmarking , Sensibilidad y Especificidad , Adenoma Corticosuprarrenal/diagnóstico por imagen , Adenoma/diagnóstico por imagen , Neoplasias de las Glándulas Suprarrenales/diagnóstico por imagen , Neoplasias de las Glándulas Suprarrenales/secundario
4.
AJR Am J Roentgenol ; 220(1): 134-140, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35920705

RESUMEN

BACKGROUND. Radiology informatics systems and clinical decision support tools in the electronic health record (EHR) can be leveraged to help impact ordering patterns in response to the ongoing global iodinated contrast media shortage. OBJECTIVE. The purpose of our study was to assess the impact of EHR order entry-based interventions, implemented as part of a health system's response to the global contrast media shortage, on contrast-enhanced CT utilization. METHODS. This retrospective study included 79,259 patients who underwent CT at a large multisite health system between April 1, 2022, and July 3, 2022. Two EHR-based interventions were implemented as part of the health system's response to the global contrast media shortage. A first EHR-based intervention on May 10, 2022, entailed creating an alert that appeared in a sidebar after any contrast-enhanced body CT orders, indicating the present shortage and recommending alternate imaging modalities. A second EHR-based intervention on May 16, 2022, required referrers to enter detailed clinical information for all contrast-enhanced body CT orders, which radiologists used when protocoling examinations. Data regarding CT orders and examinations performed were extracted from the electronic data warehouse. RESULTS. During the preintervention, first postintervention, and second postintervention periods, the mean number of patients who underwent contrast-enhanced CT per weekday was 726, 689, and 639, respectively (p for preintervention vs second postintervention periods, < .001). During the three periods, the mean number of patients who underwent CT per weekday was 1350, 1323, and 1314 (p < .001). During the three periods, the mean number of patients who underwent contrast-enhanced body CT per weekday was 561, 532, and 492 (p < .001). During the three periods, the mean number of orders for CT with IV contrast media per weekday was 154, 143, and 131 (p < .001). During the three periods, the mean number of orders for CT without IV contrast media per weekday was 196, 202, and 221 (p < .001). CONCLUSION. EHR order entry-based interventions implemented in response to the global contrast media shortage significantly reduced contrast-enhanced CT utilization in a large health system. CLINICAL IMPACT. The findings indicate the ability to rapidly achieve changes in ordering clinician behavior and subsequent clinical practice using systemwide EHR changes.


Asunto(s)
Registros Electrónicos de Salud , Radiología , Humanos , Medios de Contraste , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
5.
AJR Am J Roentgenol ; 221(4): 486-501, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37195792

RESUMEN

BACKGROUND. Patients with cancer undergo frequent CT examinations with iodinated contrast media and may be uniquely predisposed to contrast-associated acute kidney injury (CA-AKI). OBJECTIVE. The purpose of this study was to develop and validate a model for predicting the risk of CA-AKI after contrast-enhanced CT in patients with cancer. METHODS. This retrospective study included 25,184 adult patients (12,153 men, 13,031 women; mean age, 62.3 ± 13.7 [SD] years) with cancer who underwent 46,593 contrast-enhanced CT examinations between January 1, 2016, and June 20, 2020, at one of three academic medical centers. Information was recorded regarding demographics, malignancy type, medication use, baseline laboratory values, and comorbid conditions. CA-AKI was defined as a 0.3-mg/dL or greater increase in serum creatinine level from baseline within 48 hours after CT or a 1.5-fold or greater increase in the peak measurement within 14 days after CT. Multivariable models accounting for correlated data were used to identify risk factors for CA-AKI. A risk score for predicting CA-AKI was generated in a development set (n = 30,926) and tested in a validation set (n = 15,667). RESULTS. CA-AKI occurred after 5.8% (2682/46,593) of CT examinations. The final multivariable model for predicting CA-AKI included hematologic malignancy, diuretic use, angiotensin-converting enzyme inhibitor or angiotensin receptor blocker use, chronic kidney disease (CKD) stage 3a, CKD stage 3b, CKD stage 4 or 5, serum albumin level less than 3.0 g/dL, platelet count less than 150 × 103/µL, 1+ or greater proteinuria on baseline urinalysis, diabetes mellitus, heart failure, and contrast medium volume 100 mL or greater. A risk score (range, 0-53 points) was generated with these variables. The most points (13) were for CKD stage 4 or 5 and for albumin level less than 3 g/dL. The frequency of CA-AKI progressively increased in higher risk categories. For example, in the validation set, CA-AKI occurred after 2.2% of CT examinations in the lowest risk category (score ≤ 4) and after 32.7% of CT examinations in the highest risk category (score ≥ 30). The Hosmer-Lemeshow test result indicated that the risk score was a good fit (p = .40). CONCLUSION. A risk model in which readily available clinical data are used to predict the likelihood of CA-AKI after contrast-enhanced CT in patients with cancer was developed and validated. CLINICAL IMPACT. The model may help facilitate appropriate implementation of preventive measures in the care of patients at high risk of CA-AKI.


Asunto(s)
Lesión Renal Aguda , Neoplasias , Insuficiencia Renal Crónica , Masculino , Adulto , Humanos , Femenino , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Medios de Contraste/efectos adversos , Lesión Renal Aguda/inducido químicamente , Lesión Renal Aguda/diagnóstico por imagen , Lesión Renal Aguda/epidemiología , Factores de Riesgo , Neoplasias/complicaciones , Tomografía Computarizada por Rayos X/efectos adversos
6.
J Comput Assist Tomogr ; 47(3): 369-375, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37184998

RESUMEN

OBJECTIVE: The aim of the study is to determine whether computed tomography (CT) urography (CTU) can characterize incidental adrenal nodules. METHODS: This retrospective cohort study was performed at an academic medical center. Patients were identified by free text search of CTU reports that contained the terms "adrenal mass" "adrenal nodule" and "adrenal lesion." Computed tomography urography technique consisted of unenhanced images and postcontrast images obtained at 100 seconds and 15 minutes. The final cohort included 145 patients with 151 adrenal nodules. Nodules were considered lipid-rich adenomas or myelolipomas based on unenhanced imaging characteristics. Absolute and relative washout values were calculated for the remaining nodules, using a cutoff of 60% and 40%, respectively, to diagnose adenomas. Reference standard for lipid-poor adenomas and malignant nodules was histopathology or imaging/clinical follow-up. Mann-Whitney U test was used for comparison of continuous variables, and Fisher exact test was used for categorical variables. RESULTS: One hundred nodules were lipid-rich adenomas and 3 were myelolipomas. Forty-eight nodules were indeterminate at unenhanced CT, corresponding to 39 lipid-poor adenomas and 9 malignant nodules based on reference standards. Both absolute and relative washout correctly characterized 71% of nodules (34/48), with a sensitivity of 67% and specificity of 89%. Overall, 91% of all adrenal nodules (137/151) were correctly characterized by CTU alone. Lipid-poor adenomas were smaller than malignant nodules ( P < 0.01) and were lower in attenuation on unenhanced and delayed images ( P < 0.01). CONCLUSIONS: Adrenal nodules detected at 3-phase CTU can be accurately characterized, potentially eliminating the need for subsequent adrenal protocol CT or magnetic resonance imaging.


Asunto(s)
Adenoma , Neoplasias de las Glándulas Suprarrenales , Mielolipoma , Humanos , Neoplasias de las Glándulas Suprarrenales/diagnóstico por imagen , Estudios Retrospectivos , Medios de Contraste , Tomografía Computarizada por Rayos X/métodos , Adenoma/diagnóstico por imagen , Diagnóstico Diferencial , Lípidos , Sensibilidad y Especificidad
7.
AJR Am J Roentgenol ; 219(3): 462-470, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35383485

RESUMEN

BACKGROUND. Practices vary for screening patients for risk of renal dysfunction before administration of iodinated contrast medium. A 2020 American College of Radiology/National Kidney Foundation (ACR/NKF) consensus statement provided streamlined screening criteria. OBJECTIVE. The purpose of this study was to assess the yield of patient-reported risk factors for identifying estimated glomerular filtration rate (eGFR) less than 30 mL/min/1.73 m2 before outpatient CT. METHODS. This retrospective study was performed at a health system that implemented an electronic screening form for patients to complete before outpatient CT encounters to report undergoing dialysis, taking cancer-treating medications, having kidney disease, undergoing prior kidney surgery, having diabetes mellitus treated with medication, having hypertension treated with medication, or having multiple myeloma. Patients with any risk factor were required to undergo eGFR testing before CT. Of 44,708 patients completing the form from June 1, 2020, through February 28, 2021, 10,256 patients (5315 men, 4941 women; mean age, 66.8 ± 11.9 [SD] years; range, 21-98 years) underwent eGFR testing on the day of CT. Multivariable regression analysis for predicting reduced eGFR was performed. Findings were compared with those from theoretic use of the ACR/NKF criteria. RESULTS. Same-day testing yielded eGFR less than 30 mL/min/1.73 m2 in 1.4% (144/10,256) of patients. The only significant independent predictors of low eGFR were dialysis (odds ratio [OR], 203.30], kidney disease (OR, 12.55), and diabetes mellitus treated with medication (OR, 2.44). If the ACR/NKF criteria (only kidney disease, defined as dialysis, kidney disease, or prior kidney surgery) had been followed as a trigger for eGFR testing, the number of patients needing testing would have decreased 89.7%, from 10,256 to 1059; yield would have increased to 7.2% (76/1059); and 47.2% (68/144) of patients with low eGFR would have been missed. If the ACR/NKF criteria had been followed but diabetes mellitus been considered a required rather than an optional criterion, the number of patients needing testing would have decreased 77.1%, to 2353; yield would have increased to 4.0% (95/2353); and 34.0% (49/144) of patients with low eGFR would have been missed. CONCLUSION. Using patient-reported risk factors resulted in frequent eGFR testing but low yield of low eGFR. Commonly applied risk factors were not independently associated with low eGFR. CLINICAL IMPACT. Application of ACR/NKF criteria would substantially reduce eGFR testing, but patients with renal dysfunction would be missed. The statement should consider omitting kidney surgery as a trigger for eGFR testing and including diabetes mellitus as a required trigger.


Asunto(s)
Diabetes Mellitus , Insuficiencia Renal Crónica , Anciano , Diabetes Mellitus/etiología , Femenino , Tasa de Filtración Glomerular , Humanos , Riñón , Masculino , Persona de Mediana Edad , Pacientes Ambulatorios , Medición de Resultados Informados por el Paciente , Insuficiencia Renal Crónica/diagnóstico por imagen , Insuficiencia Renal Crónica/etiología , Estudios Retrospectivos , Factores de Riesgo , Tomografía Computarizada por Rayos X/métodos
8.
Int J Hyperthermia ; 39(1): 34-39, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34937523

RESUMEN

PURPOSE: To assess the impact of periprocedural factors, including adverse events, on overall patient survival following image-guided liver tumor cryoablation procedures. METHODS: In this retrospective single-institution study, 143 patients (73 male, 70 female, ages 29-88) underwent 169 image-guided liver tumor cryoablation procedures between October 1998 and August 2014. Patient, tumor and procedural variables were recorded. The primary outcome was overall survival post-procedure (Kaplan-Meier analysis). Secondary outcomes were the impact of 15 variables on patient survival, which were assessed with multivariate cox regression and log-rank tests. RESULTS: Mean tumor diameter was 2.5 ± 1.2 cm. 26 of 143 (18.2%) patients had primary hepatic malignancies; 117 of 143 (81.8%) had liver metastases. Survival analysis revealed survivor functions at 3, 5, 7, 10 and 12 years post-ablation of 0.54, 0.37, 0.30, 0.17 and 0.06, with mean survival time of 40.8 ± 4.9 months. Tumor size ≥4 cm (p = .018), pre-procedural platelet count <100 × 103/µL (p = .023), and prior local radiation therapy (p = .014) were associated with worse overall patient survival. Grade 3 or higher adverse events were not associated with reduced survival (p = .49). CONCLUSIONS: All variables associated with overall survival were patient-related and none were associated with the cryoablation procedure. Pre-procedural thrombocytopenia, larger tumor size and history of prior local radiation therapy were independent risk factors for reduced overall survival in patients undergoing hepatic cryoablation. Adverse events related to hepatic cryoablation were not associated with decreased survival.


Asunto(s)
Criocirugía , Neoplasias Hepáticas , Adulto , Anciano , Anciano de 80 o más Años , Criocirugía/métodos , Femenino , Humanos , Estimación de Kaplan-Meier , Neoplasias Hepáticas/etiología , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/cirugía , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
9.
Am J Emerg Med ; 50: 10-13, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34271230

RESUMEN

PURPOSE: To assess the association of imaging features of acute pancreatitis (AP) with the magnitude of lipase elevation in Emergency Department (ED) patients. METHODS: This Institutional Review Board-approved retrospective study included 509 consecutive patients presenting from 9/1/13-8/31/15 to a large academic ED with serum lipase levels ≥3× the upper limit of normal (ULN) (≥180 U/L). Patients were excluded if they did not have imaging (n = 131) or had a history of trauma, abdominal metastases, altered mental status, or transfer from an outside hospital (n = 190); the final study population was 188 patients. Imaging exams were retrospectively evaluated, and a consensus opinion of two subspecialty-trained abdominal radiologists was used to diagnose AP. Primary outcome was presence of imaging features of AP stratified by lipase level (≥3×-10× ULN and > 10× ULN). Secondary outcome was rate of discordant consensus evaluation compared to original radiologist's report. RESULTS: 25.0% of patients (47/188) had imaging features of AP. When lipase was >10× ULN (n = 94), patients were more likely to have imaging features of AP (34%) vs. those with mild elevation (16%) (p = 0.0042). There was moderately strong correlation between lipase level and presence of imaging features of AP (r = 0.48, p < 0.0001). Consensus review of CT and MRI images was discordant with the original report in 14.9% (28/188) of cases. CONCLUSION: Prevalence of imaging signs of AP in an ED population with lipase ≥3× ULN undergoing imaging is low. However, the probability of imaging features of AP increases as lipase value increases.


Asunto(s)
Servicio de Urgencia en Hospital , Lipasa/sangre , Pancreatitis/diagnóstico por imagen , Pancreatitis/enzimología , Biomarcadores/sangre , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Prevalencia , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
10.
AJR Am J Roentgenol ; 214(4): 835-842, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32023118

RESUMEN

OBJECTIVE. The objective of this study was to assess impact of a report template quality improvement (QI) initiative on use of preferred phrases for communicating normal findings in structured abdominal CT and MRI reports. SUBJECTS AND METHODS. This prospective QI initiative, designed to decrease use of equivocal phrases and increase use of preferred and acceptable phrases (defined by multidisciplinary experts including patient advocates) in radiology reports, was performed in an academic medical center with over 800,000 annual radiologic examinations and was exempt from institutional review board approval. The intervention populated the preferred term "normal" (default) and acceptable specified pertinent negative phrases (pick-list option) when describing abdominal organ subheadings (liver, pancreas, spleen, adrenal glands, kidneys) within the "Findings" heading of abdominal CT and MRI report templates. We tabulated frequencies of the term "normal", specified pertinent negatives, and equivocal phrases in 21,629 reports before (June 1, 2017, to February 28, 2018) and 23,051 reports after (April 1, 2018, to December 31, 2018) the intervention using natural language processing and recorded trainee participation in report generation. We assessed intervention impact using statistical process control (SPC) charts and the Fisher exact test. RESULTS. Equivocal phrases were used less frequently in abdominal CT and MRI reports for both attending radiologists and trainees after the intervention (p < 0.05, SPC). Use of the term "normal" increased for reports generated by attending radiologists alone but decreased for reports created with trainee participation (p < 0.05, SPC). Frequency of pertinent negatives increased for reports with trainee participation (p < 0.05, SPC). CONCLUSION. A QI intervention decreased use of equivocal terms and increased use of preferred and acceptable phrases when communicating normal findings in abdominal CT and MRI reports.


Asunto(s)
Control de Formularios y Registros/normas , Imagen por Resonancia Magnética , Mejoramiento de la Calidad , Terminología como Asunto , Tomografía Computarizada por Rayos X , Humanos , Estudios Prospectivos , Sistemas de Información Radiológica
13.
AJR Am J Roentgenol ; 213(5): 1008-1014, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31414884

RESUMEN

OBJECTIVE. Variability in reports of the same imaging study performed at the same institution may be confusing to referrers and patients, hindering results communication. The purpose of this study was to introduce a quality improvement initiative aimed at reducing variation in radiology report templates at a large academic center. MATERIALS AND METHODS. The quality improvement initiative was undertaken at a large multisite, multidivision academic radiology practice performing more than 820,000 radiologic examinations annually. A project charter defined the goals, scope, and personnel of the initiative and an escalation pathway for conflict resolution. Standard requirements for templates were initially developed. From September 2017 to May 2018, an oversight committee (24 organ system and modality-based work groups with representatives from nine subspecialty divisions) reviewed and harmonized all institutional radiology report templates across the enterprise irrespective of the imaging site or division that interpreted the study. The primary outcome measure was percentage reduction in report templates after harmonization. The secondary outcome measure was monthly adherence to harmonized templates for 9 months after implementation assessed by manual review of 40 randomly selected reports per month. The paired t test was used to assess template reduction, and the chi-square trend test was used to study trend in adherence to harmonized templates. RESULTS. Among 19,687 total templates at baseline, 597 harmonized templates remained after harmonization (p < 0.001). There was variation in template reduction by work group (multiple p < 0.05; reduction range, 79.2-99.3%). Radiologist adherence to harmonized templates ranged from 88.0% to 100%, unchanged in the 9 months after implementation (p = 0.23, chi-square trend). CONCLUSION. A radiology report harmonization initiative reduced 97.0% of report templates with a sustained high degree of adherence to harmonized templates after implementation at a large multisite multidivision academic radiology practice.


Asunto(s)
Servicio de Radiología en Hospital/organización & administración , Sistemas de Información Radiológica/normas , Centros Médicos Académicos , Boston , Humanos , Registro Médico Coordinado , Evaluación de Procesos, Atención de Salud , Mejoramiento de la Calidad , Estudios Retrospectivos
14.
AJR Am J Roentgenol ; 213(5): 1003-1007, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31216200

RESUMEN

OBJECTIVE. The purpose of this study was to evaluate the technologist productivity and accuracy in assigning protocols for abdominal CT and MRI examinations compared with a standard work flow whereby protocols are assigned by physicians. MATERIALS AND METHODS. In this quality improvement project at a large academic medical center, two CT technologists and two MRI technologists assigned protocols for examinations during a 15-week study period. The primary outcome measure was mean number of protocols assigned by technologists per hour. Secondary outcome measures were proportion of examinations with protocols assigned by technologists and rate of filing of quality assurance reports for protocols completed by technologists. A two-tailed t test was used to compare mean number of protocols; a chi-square test was used to compare proportions between CT and MRI. RESULTS. The mean number of protocols assigned by technologists per hour was not different between CT and MRI (CT, 22/h; MRI, 19/h; p = 0.28). CT and MRI technologist protocols accounted for 1650 of 4867 (33.9%) CT examinations (range, 23-275 per week) and 569 of 2388 (23.8%) MRI examinations (range, 0-95 per week) (p < 0.001). Radiologist quality assurance reports on inaccurate protocols were rare: three for CT (3/1650 [0.18%]), five for MRI (5/569 [0.88%]) (p = 0.017). A retrospective review of randomly selected CT and MRI protocols revealed no errors (80/80 correct). No patients were called back for repeat imaging due to protocol error. CONCLUSION. Technologists can efficiently and accurately assign protocols for abdominal CT and MRI examinations at an academic medical center, leading to increased radiologist time spent on other value-added activities.


Asunto(s)
Eficiencia , Imagen por Resonancia Magnética , Radiografía Abdominal , Radiólogos/estadística & datos numéricos , Tecnología Radiológica , Tomografía Computarizada por Rayos X , Carga de Trabajo/estadística & datos numéricos , Centros Médicos Académicos , Competencia Clínica , Femenino , Humanos , Masculino , Mejoramiento de la Calidad , Estudios Retrospectivos
16.
AJR Am J Roentgenol ; 209(6): 1381-1389, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28952807

RESUMEN

OBJECTIVE: The purpose of this article is to report our intermediate to long-term outcomes with image-guided percutaneous hepatic tumor cryoablation and to evaluate its technical success, technique efficacy, local tumor progression, and adverse event rate. MATERIALS AND METHODS: Between 1998 and 2014, 299 hepatic tumors (243 metastases and 56 primary tumors; mean diameter, 2.5 cm; median diameter, 2.2 cm; range, 0.3-7.8 cm) in 186 patients (95 women; mean age, 60.9 years; range, 29-88 years) underwent cryoablation during 236 procedures using CT (n = 126), MRI (n = 100), or PET/CT (n = 10) guidance. Technical success, technique efficacy at 3 months, local tumor progression (mean follow-up, 2.5 years; range, 2 months to 14.6 years), and adverse event rates were calculated. RESULTS: The technical success rate was 94.6% (279/295). The technique efficacy rate was 89.5% (231/258) and was greater for tumors smaller than 4 cm (93.4%; 213/228) than for larger tumors (60.0%; 18/30) (p < 0.0001). Local tumor progression occurred in 23.3% (60/258) of tumors and was significantly more common after the treatment of tumors 4 cm or larger (63.3%; 19/30) compared with smaller tumors (18.0%; 41/228) (p < 0.0001). Adverse events followed 33.8% (80/236) of procedures and were grade 3-5 in 10.6% (25/236) of cases. Grade 3 or greater adverse events more commonly followed the treatment of larger tumors (19.5%; 8/41) compared with smaller tumors (8.7%; 17/195) (p = 0.04). CONCLUSION: Image-guided percutaneous cryoablation of hepatic tumors is efficacious; however, tumors smaller than 4 cm are more likely to be treated successfully and without an adverse event.


Asunto(s)
Criocirugía/métodos , Neoplasias Hepáticas/cirugía , Imagen por Resonancia Magnética Intervencional , Radiografía Intervencional , Adulto , Anciano , Anciano de 80 o más Años , Progresión de la Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
17.
AJR Am J Roentgenol ; 209(3): W145-W151, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28657843

RESUMEN

OBJECTIVE: The purpose of this study is to determine the interobserver agreement of the Prostate Imaging Reporting and Data System version 2 (PI-RADSv2) for diagnosing prostate cancer using in-bore MRI-guided prostate biopsy as the reference standard. MATERIALS AND METHODS: Fifty-nine patients underwent in-bore MRI-guided prostate biopsy between January 21, 2010, and August 21, 2013, and underwent diagnostic multiparametric MRI 6 months or less before biopsy. A single index lesion per patient was selected after retrospective review of MR images. Three fellowship-trained abdominal radiologists (with 1-11 years' experience) blinded to clinical information interpreted all studies according to PI-RADSv2. Interobserver agreement was assessed using Cohen kappa statistics. RESULTS: Thirty-eight lesions were in the peripheral zone and 21 were in the transition zone. Cancer was diagnosed in 26 patients (44%). Overall PI-RADS scores were higher for all biopsy-positive lesions (mean ± SD, 3.9 ± 1.1) than for biopsy-negative lesions (3.1 ± 1.0; p < 0.0001) and for clinically significant lesions (4.2 ± 1.0) than for clinically insignificant lesions (3.1 ± 1.0; p < 0.0001). Overall suspicion score interobserver agreement was moderate (κ = 0.45). There was moderate interobserver agreement among overall PI-RADS scores in the peripheral zone (κ = 0.46) and fair agreement in the transition zone (κ = 0.36). CONCLUSION: PI-RADSv2 scores were higher in the biopsy-positive group. PI-RADSv2 showed moderate interobserver agreement among abdominal radiologists with no prior experience using the scoring system.


Asunto(s)
Biopsia Guiada por Imagen/métodos , Imagen por Resonancia Magnética/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos
18.
Radiology ; 272(1): 132-42, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24555636

RESUMEN

PURPOSE: To determine for expert and novice radiologists repeatability of major diagnostic features and scoring systems (ie, Liver Imaging Reporting and Data System [LI-RADS], Organ Procurement and Transplantation Network [OPTN], and American Association for the Study of Liver Diseases [AASLD]) for hepatocellular carcinoma (HCC) by using magnetic resonance (MR) imaging. MATERIALS AND METHODS: Institutional review board approval was obtained and patient consent was waived for this HIPAA-compliant, retrospective study. The LI-RADS discussed in this article refers to version 2013.1. Ten blinded readers reviewed 100 liver MR imaging studies that demonstrated observations preliminarily assigned LI-RADS scores of LR1-LR5. Diameter and major HCC features (arterial hyperenhancement, washout appearance, pseudocapsule) were recorded for each observation. LI-RADS, OPTN, and AASLD scores were assigned. Interreader agreement was assessed by using intraclass correlation coefficients and κ statistics. Scoring rates were compared by using McNemar test. RESULTS: Overall interreader agreement was substantial for arterial hyperenhancement (0.67 [95% confidence interval {CI}: 0.65, 0.69]), moderate for washout appearance (0.48 [95%CI: 0.46, 0.50]), moderate for pseudocapsule (0.52 [95% CI: 050, 0.54]), fair for LI-RADS (0.35 [95% CI: 0.34, 0.37]), fair for AASLD (0.39 [95% CI: 0.37, 0.42]), and moderate for OPTN (0.53 [95% CI: 0.51, 0.56]). Agreement for measured diameter was almost perfect (range, 0.95-0.97). There was substantial agreement for most scores consistent with HCC. Experts agreed significantly more than did novices and were significantly more likely than were novices to assign a diagnosis of HCC (P < .001). CONCLUSION: Two of three major features for HCC (washout appearance and pseudocapsule) have only moderate interreader agreement. Experts and novices who assigned scores consistent with HCC had substantial but not perfect agreement. Expert agreement is substantial for OPTN, but moderate for LI-RADS and AASLD. Novices were less consistent and less likely to diagnose HCC than were experts.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico , Competencia Clínica , Neoplasias Hepáticas/diagnóstico , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma Hepatocelular/patología , Medios de Contraste , Femenino , Humanos , Imagenología Tridimensional , Neoplasias Hepáticas/patología , Masculino , Meglumina/análogos & derivados , Persona de Mediana Edad , Compuestos Organometálicos , Reproducibilidad de los Resultados , Estudios Retrospectivos
19.
AJR Am J Roentgenol ; 203(6): 1230-5, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25415699

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate stone detection, assessment of secondary signs of stone disease, and diagnostic confidence utilizing submillisievert CT with model-based iterative reconstruction (MBIR) in a North American population with diverse body habitus. MATERIALS AND METHODS: Fifty-two adults underwent stone CT using a split-dose protocol; weight-based projected volume CT dose index (CTDIvol) and dose-length product (DLP) were divided into two separate acquisitions at 80% and 20% dose levels. Images were reconstructed with MBIR. Five blinded readers counted stones in three size categories and rated "overall diagnostic confidence" and "detectability of secondary signs of stone disease" on a 0-4 scale at both dose levels. Effective dose (ED) in mSv was calculated as DLP multiplied by conversion coefficient, k, equal to 0.017. RESULTS: Mean ED (80%, 3.90±1.44 mSv; vs 20%, 0.97±0.34 mSv [p<0.001]) and number of stones detected (80%, 193.6±25.0; vs 20%, 154.4±15.4 [p=0.03]) were higher in scans at 80% dose level. Intrareader correlation between scans at 80% and 20% dose levels was excellent (0.83-0.97). With 80% scans as reference standard, mean sensitivity and specificity at 20% varied with stone size (<3 mm, 74% and 77%; ≥3 mm, 92% and 82%). The 20% scans scored lower than 80% scans in diagnostic confidence (2.46±0.50; vs 3.21±0.36 [p<0.005]) and detectability of secondary signs (2.41±0.39; vs 3.19±0.29 [p<0.005]). CONCLUSION: Aggressively dose-reduced (~1 mSv) MBIR scans detected most urinary tract stones of 3 mm or larger but underperformed the low-dose reference standard (3-4 mSv) scans in small (<3 mm) stone detection and diagnostic confidence.


Asunto(s)
Modelos Biológicos , Dosis de Radiación , Protección Radiológica/métodos , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Urolitiasis/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Simulación por Computador , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
20.
AJR Am J Roentgenol ; 203(2): 329-35, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25055267

RESUMEN

OBJECTIVE: The purpose of this article is to evaluate single-source dual-energy CT (DECT) for distinguishing benign and indeterminate adrenal nodules, with attention to the effects of phase of IV contrast enhancement. MATERIALS AND METHODS: A retrospective review revealed 273 contrast-enhanced abdominal DECT examinations from November 2009 through March 2012. Fifty adrenal nodules 0.8 cm or larger were identified in 41 patients (22 women and 19 men; average age, 66 years; age range, 36-88 years). CT postprocessing and measurements were independently performed by two radiologists (readers 1 and 2) for each nodule, as follows: attenuation (in Hounsfield units) on true unenhanced images; contrast-enhanced attenuation (in Hounsfield units) on monochromatic spectral images at 40, 75, and 140 keV; and contrast-enhanced material density (in milligrams per milliliter) on virtual unenhanced images. Nodules were classified as benign (< 10 HU) and indeterminate (≥ 10 HU) according to true unenhanced images. RESULTS: Interreader agreement regarding benign and indeterminate nodules was high (κ = 0.92; 95% CI, 0.8-1.0). At 140 keV, the attenuation of benign nodules was significantly lower (reader 1, 7.0 ± 12.5 HU; reader 2, 7.8 ± 9.2 HU) than that of indeterminate nodules (reader 1, 15.7 ± 20.5 HU [p = 0.004]; reader 2, 17.5 ± 13.4 HU [p < 0.0001]). On virtual unenhanced images, benign nodules had significantly lower material density (reader 1, 992.4 ± 9.9 mg/mL; reader 2, 992.7 ± 9.6 mg/mL) than did indeterminate nodules (reader 1, 1001.1 ± 20.5 mg/mL [p = 0.038]; reader 2, 1007.6 ± 13.4 mg/mL [p < 0.0001]). CONCLUSION: DECT tools can mathematically subtract iodine or minimize its effects in high-energy reconstructions, approximating unenhanced imaging and potentially reducing the need for additional studies to triage adrenal nodules detected on contrast-enhanced DECT examinations.


Asunto(s)
Neoplasias de las Glándulas Suprarrenales/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador , Estudios Retrospectivos , Técnica de Sustracción , Triaje
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA