Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 361
Filtrar
Más filtros

Intervalo de año de publicación
1.
Annu Rev Immunol ; 37: 97-123, 2019 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-31026412

RESUMEN

The B cell antigen receptor (BCR) plays a central role in the self/nonself selection of B lymphocytes and in their activation by cognate antigen during the clonal selection process. It was long thought that most cell surface receptors, including the BCR, were freely diffusing and randomly distributed. Since the advent of superresolution techniques, it has become clear that the plasma membrane is compartmentalized and highly organized at the nanometer scale. Hence, a complete understanding of the precise conformation and activation mechanism of the BCR must take into account the organization of the B cell plasma membrane. We review here the recent literature on the nanoscale organization of the lymphocyte membrane and discuss how this new information influences our view of the conformational changes that the BCR undergoes during activation.


Asunto(s)
Linfocitos B/inmunología , Membrana Celular/metabolismo , Receptores de Antígenos de Linfocitos B/metabolismo , Regulación Alostérica , Animales , Compartimento Celular , Humanos , Activación de Linfocitos , Nanomedicina , Conformación Proteica
2.
N Engl J Med ; 390(2): 107-117, 2024 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-37952132

RESUMEN

BACKGROUND: Subclinical atrial fibrillation is short-lasting and asymptomatic and can usually be detected only by long-term continuous monitoring with pacemakers or defibrillators. Subclinical atrial fibrillation is associated with an increased risk of stroke by a factor of 2.5; however, treatment with oral anticoagulation is of uncertain benefit. METHODS: We conducted a trial involving patients with subclinical atrial fibrillation lasting 6 minutes to 24 hours. Patients were randomly assigned in a double-blind, double-dummy design to receive apixaban at a dose of 5 mg twice daily (2.5 mg twice daily when indicated) or aspirin at a dose of 81 mg daily. The trial medication was discontinued and anticoagulation started if subclinical atrial fibrillation lasting more than 24 hours or clinical atrial fibrillation developed. The primary efficacy outcome, stroke or systemic embolism, was assessed in the intention-to-treat population (all the patients who had undergone randomization); the primary safety outcome, major bleeding, was assessed in the on-treatment population (all the patients who had undergone randomization and received at least one dose of the assigned trial drug, with follow-up censored 5 days after permanent discontinuation of trial medication for any reason). RESULTS: We included 4012 patients with a mean (±SD) age of 76.8±7.6 years and a mean CHA2DS2-VASc score of 3.9±1.1 (scores range from 0 to 9, with higher scores indicating a higher risk of stroke); 36.1% of the patients were women. After a mean follow-up of 3.5±1.8 years, stroke or systemic embolism occurred in 55 patients in the apixaban group (0.78% per patient-year) and in 86 patients in the aspirin group (1.24% per patient-year) (hazard ratio, 0.63; 95% confidence interval [CI], 0.45 to 0.88; P = 0.007). In the on-treatment population, the rate of major bleeding was 1.71% per patient-year in the apixaban group and 0.94% per patient-year in the aspirin group (hazard ratio, 1.80; 95% CI, 1.26 to 2.57; P = 0.001). Fatal bleeding occurred in 5 patients in the apixaban group and 8 patients in the aspirin group. CONCLUSIONS: Among patients with subclinical atrial fibrillation, apixaban resulted in a lower risk of stroke or systemic embolism than aspirin but a higher risk of major bleeding. (Funded by the Canadian Institutes of Health Research and others; ARTESIA ClinicalTrials.gov number, NCT01938248.).


Asunto(s)
Anticoagulantes , Aspirina , Fibrilación Atrial , Embolia , Accidente Cerebrovascular , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Anticoagulantes/efectos adversos , Anticoagulantes/uso terapéutico , Aspirina/efectos adversos , Aspirina/uso terapéutico , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Canadá , Embolia/etiología , Embolia/prevención & control , Hemorragia/inducido químicamente , Piridonas/efectos adversos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento , Inhibidores del Factor Xa/efectos adversos , Inhibidores del Factor Xa/uso terapéutico , Método Doble Ciego
3.
Circulation ; 147(10): 812-823, 2023 03 07.
Artículo en Inglés | MEDLINE | ID: mdl-36700426

RESUMEN

BACKGROUND: Benefit from cardiac resynchronization therapy (CRT) varies by QRS characteristics; individual randomized trials are underpowered to assess benefit for relatively small subgroups. METHODS: The authors analyzed patient-level data from pivotal CRT trials (MIRACLE [Multicenter InSync Randomized Clinical Evaluation], MIRACLE-ICD [Multicenter InSync ICD Randomized Clinical Evaluation], MIRACLE-ICD II [Multicenter InSync ICD Randomized Clinical Evaluation II], REVERSE [Resynchronization Reverses Remodeling in Systolic Left Ventricular Dysfunction], RAFT [Resynchronization-Defibrillation for Ambulatory Heart Failure], BLOCK-HF [Biventricular Versus Right Ventricular Pacing in Heart Failure Patients with Atrioventricular Block], COMPANION [Comparison of Medical Therapy, Pacing and Defibrillation in Heart Failure], and MADIT-CRT [Multicenter Automatic Defibrillator Implantation Trial - Cardiac Resynchronization Therapy]) using Bayesian Hierarchical Weibull survival regression models to assess CRT benefit by QRS morphology (left bundle branch block [LBBB], n=4549; right bundle branch block [RBBB], n=691; and intraventricular conduction delay [IVCD], n=1024) and duration (with 150-ms partition). The continuous relationship between QRS duration and CRT benefit was also examined within subgroups defined by QRS morphology. The primary end point was time to heart failure hospitalization (HFH) or death; a secondary end point was time to all-cause death. RESULTS: Of 6264 patients included, 25% were women, the median age was 66 [interquartile range, 58 to 73] years, and 61% received CRT (with or without an implantable cardioverter defibrillator). CRT was associated with an overall lower risk of HFH or death (hazard ratio [HR], 0.73 [credible interval (CrI), 0.65 to 0.84]), and in subgroups of patients with QRS ≥150 ms and either LBBB (HR, 0.56 [CrI, 0.48 to 0.66]) or IVCD (HR, 0.59 [CrI, 0.39 to 0.89]), but not RBBB (HR 0.97 [CrI, 0.68 to 1.34]; Pinteraction <0.001). No significant association for CRT with HFH or death was observed when QRS was <150 ms (regardless of QRS morphology) or in the presence of RBBB. Similar relationships were observed for all-cause death. CONCLUSIONS: CRT is associated with reduced HFH or death in patients with QRS ≥150 ms and LBBB or IVCD, but not for those with RBBB. Aggregating RBBB and IVCD into a single "non-LBBB" category when selecting patients for CRT should be reconsidered. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifiers: NCT00271154, NCT00251251, NCT00267098, and NCT00180271.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Femenino , Anciano , Masculino , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/terapia , Bloqueo de Rama/complicaciones , Terapia de Resincronización Cardíaca/efectos adversos , Teorema de Bayes , Ensayos Clínicos Controlados Aleatorios como Asunto , Desfibriladores Implantables/efectos adversos , Resultado del Tratamiento , Electrocardiografía
4.
Lancet ; 402(10408): 1147-1157, 2023 09 30.
Artículo en Inglés | MEDLINE | ID: mdl-37634520

RESUMEN

BACKGROUND: Continuous automatic optimisation of cardiac resynchronisation therapy (CRT), stimulating only the left ventricle to fuse with intrinsic right bundle conduction (synchronised left ventricular stimulation), might offer better outcomes than conventional CRT in patients with heart failure, left bundle branch block, and normal atrioventricular conduction. This study aimed to compare clinical outcomes of adaptive CRT versus conventional CRT in patients with heart failure with intact atrioventricular conduction and left bundle branch block. METHODS: This global, prospective, randomised controlled trial was done in 227 hospitals in 27 countries across Asia, Australia, Europe, and North America. Eligible patients were aged 18 years or older with class 2-4 heart failure, an ejection fraction of 35% or less, left bundle branch block with QRS duration of 140 ms or more (male patients) or 130 ms or more (female patients), and a baseline PR interval 200 ms or less. Patients were randomly assigned (1:1) via block permutation to adaptive CRT (an algorithm providing synchronised left ventricular stimulation) or conventional biventricular CRT using a device programmer. All patients received device programming but were masked until procedures were completed. Site staff were not masked to group assignment. The primary outcome was a composite of all-cause death or intervention for heart failure decompensation and was assessed in the intention-to-treat population. Safety events were collected and reported in the intention-to-treat population. This study is registered with ClinicalTrials.gov, NCT02205359, and is closed to accrual. FINDINGS: Between Aug 5, 2014, and Jan 31, 2019, of 3797 patients enrolled, 3617 (95·3%) were randomly assigned (1810 to adaptive CRT and 1807 to conventional CRT). The futility boundary was crossed at the third interim analysis on June 23, 2022, when the decision was made to stop the trial early. 1568 (43·4%) of 3617 patients were female and 2049 (56·6%) were male. Median follow-up was 59·0 months (IQR 45-72). A primary outcome event occurred in 430 of 1810 patients (Kaplan-Meier occurrence rate 23·5% [95% CI 21·3-25·5] at 60 months) in the adaptive CRT group and in 470 of 1807 patients (25·7% [23·5-27·8] at 60 months) in the conventional CRT group (hazard ratio 0·89, 95% CI 0·78-1·01; p=0·077). System-related adverse events were reported in 452 (25·0%) of 1810 patients in the adaptive CRT group and 440 (24·3%) of 1807 patients in the conventional CRT group. INTERPRETATION: Compared with conventional CRT, adaptive CRT did not significantly reduce the incidence of all-cause death or intervention for heart failure decompensation in the included population of patients with heart failure, left bundle branch block, and intact AV conduction. Death and heart failure decompensation rates were low with both CRT therapies, suggesting a greater response to CRT occurred in this population than in patients in previous trials. FUNDING: Medtronic.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Masculino , Femenino , Bloqueo de Rama/etiología , Bloqueo de Rama/terapia , Estudios Prospectivos , Resultado del Tratamiento , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Volumen Sistólico , Electrocardiografía
5.
Am Heart J ; 267: 81-90, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37984672

RESUMEN

BACKGROUND: Cardiac resynchronization therapy (CRT) reduces heart failure hospitalizations (HFH) and mortality for guideline-indicated patients with heart failure (HF). Most patients with HF are aged ≥70 years but such patients are often under-represented in randomized trials. METHODS: Patient-level data were combined from 8 randomized trials published 2002-2013 comparing CRT to no CRT (n = 6,369). The effect of CRT was estimated using an adjusted Bayesian survival model. Using age as a categorical (<70 vs ≥70 years) or continuous variable, the interaction between age and CRT on the composite end point of HFH or all-cause mortality or all-cause mortality alone was assessed. RESULTS: The median age was 67 years with 2436 (38%) being 70+; 1,554 (24%) were women; 2,586 (41%) had nonischemic cardiomyopathy and median QRS duration was 160 ms. Overall, CRT was associated with a delay in time to the composite end point (adjusted hazard ratio [aHR] 0.75, 95% credible interval [CI] 0.66-0.85, P = .002) and all-cause mortality alone (aHR of 0.80, 95% CI 0.69-0.96, P = .017). When age was treated as a categorical variable, there was no interaction between age and the effect of CRT for either end point (P > .1). When age was treated as a continuous variable, older patients appeared to obtain greater benefit with CRT for the composite end point (P for interaction = .027) with a similar but nonsignificant trend for mortality (P for interaction = .35). CONCLUSION: Reductions in HFH and mortality with CRT are as great or greater in appropriately indicated older patients. Age should not be a limiting factor for the provision of CRT.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Femenino , Anciano , Masculino , Teorema de Bayes , Resultado del Tratamiento , Insuficiencia Cardíaca/terapia , Modelos de Riesgos Proporcionales
6.
J Cardiovasc Electrophysiol ; 34(9): 1914-1924, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37522254

RESUMEN

AIMS: To investigate the association of cardiac resynchronization therapy (CRT) on outcomes among participants with and without a history of atrial fibrillation (AF). METHODS: Individual-patient-data from four randomized trials investigating CRT-Defibrillators (COMPANION, MADIT-CRT, REVERSE) or CRT-Pacemakers (COMPANION, MIRACLE) were analyzed. Outcomes were time to a composite of heart failure hospitalization or all-cause mortality or to all-cause mortality alone. The association of CRT on outcomes for patients with and without a history of AF was assessed using a Bayesian-Weibull survival regression model adjusting for baseline characteristics. RESULTS: Of 3964 patients included, 586 (14.8%) had a history of AF; 2245 (66%) were randomized to CRT. Overall, CRT reduced the risk of the primary composite endpoint (hazard ratio [HR]: 0.69, 95% credible interval [CI]: 0.56-0.81). The effect was similar (posterior probability of no interaction = 0.26) in patients with (HR: 0.78, 95% CI: 0.55-1.10) and without a history of AF (HR: 0.67, 95% CI: 0.55-0.80). In these four trials, CRT did not reduce mortality overall (HR: 0.82, 95% CI: 0.66-1.01) without evidence of interaction (posterior probability of no interaction = 0.14) for patients with (HR: 1.09, 95% CI: 0.70-1.74) or without a history of AF (HR: 0.70, 95% CI: 0.60-0.97). CONCLUSION: The association of CRT on the composite endpoint or mortality was not statistically different for patients with or without a history of AF, but this could reflect inadequate power. Our results call for trials to confirm the benefit of CRT recipients with a history of AF.


Asunto(s)
Fibrilación Atrial , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Terapia de Resincronización Cardíaca/métodos , Teorema de Bayes , Resultado del Tratamiento , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia
7.
Europace ; 26(1)2023 12 28.
Artículo en Inglés | MEDLINE | ID: mdl-38153385

RESUMEN

It is well established that right ventricular pacing is detrimental in patients with reduced cardiac function who require ventricular pacing (VP), and alternatives nowadays are comprised of biventricular pacing (BiVP) and conduction system pacing (CSP). The latter modality is of particular interest in patients with a narrow baseline QRS as it completely avoids, or minimizes, ventricular desynchronization associated with VP. In this article, experts debate whether BiVP or CSP should be used to treat these patients.


Asunto(s)
Bloqueo Atrioventricular , Terapia de Resincronización Cardíaca , Humanos , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/terapia , Terapia de Resincronización Cardíaca/efectos adversos , Volumen Sistólico , Trastorno del Sistema de Conducción Cardíaco , Sistema de Conducción Cardíaco
8.
Europace ; 25(8)2023 08 25.
Artículo en Inglés | MEDLINE | ID: mdl-37622580

RESUMEN

Cardiac resynchronization therapy (CRT) was proposed in the 1990s as a new therapy for patients with heart failure and wide QRS with depressed left ventricular ejection fraction despite optimal medical treatment. This review is aimed first to describe the rationale and the physiologic effects of CRT. The journey of the landmark randomized trials leading to the adoption of CRT in the guidelines since 2005 is also reported showing the high level of evidence for CRT. Different alternative pacing modalities of CRT to conventional left ventricular pacing through the coronary sinus have been proposed to increase the response rate to CRT such as multisite pacing and endocardial pacing. A new emerging alternative technique to conventional biventricular pacing, conduction system pacing (CSP), is a promising therapy. The different modalities of CSP are described (Hirs pacing and left bundle branch area pacing). This new technique has to be evaluated in clinical randomized trials before implementation in the guidelines with a high level of evidence.


Asunto(s)
Terapia de Resincronización Cardíaca , Humanos , Volumen Sistólico , Función Ventricular Izquierda , Trastorno del Sistema de Conducción Cardíaco , Sistema de Conducción Cardíaco
9.
Europace ; 25(11)2023 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-37926926

RESUMEN

AIMS: Left bundle branch area pacing (LBBAP) is a novel approach for cardiac resynchronization therapy (CRT), but the impact of myocardial substrate on its effect is poorly understood. This study aims to assess the association of cardiac magnetic resonance (CMR)-derived scar burden and the response of CRT via LBBAP. METHODS AND RESULTS: Consecutive patients with CRT indications who underwent CMR examination and successful LBBAP-CRT were retrospectively analysed. Cardiac magnetic resonance late gadolinium enhancement was used for scar assessment. Echocardiographic reverse remodelling and composite outcomes (defined as all-cause death or heart failure hospitalization) were evaluated. The echocardiographic response was defined as a ≥15% reduction of left ventricular end-systolic volume. Among the 54 patients included, LBBAP-CRT resulted in a 74.1% response rate. The non-responders had higher global, septal, and lateral scar burden (all P < 0.001). Global, septal, and lateral scar percentage all predicted echocardiographic response [area under the curve (AUC): 0.857, 0.864, and 0.822; positive likelihood ratio (+LR): 9.859, 5.594, and 3.059; and negative likelihood ratio (-LR): 0.323, 0.233, and 0.175 respectively], which was superior to QRS morphology criteria (Strauss left bundle branch abnormality: AUC: 0.696, +LR 2.101, and -LR 0.389). After a median follow-up time of 20.3 (11.5-38.7) months, higher global, lateral and septal scar burdens were all predictive of the composite outcome (hazard ratios: 4.996, 7.019, and 4.741, respectively; P's < 0.05). CONCLUSION: Lower scar burden was associated with higher response rate of LBBAP-CRT. The pre-procedure CMR scar evaluation provides further useful information to identify potential responders and clinical outcomes.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Cicatriz/diagnóstico por imagen , Cicatriz/patología , Medios de Contraste , Estudios Retrospectivos , Resultado del Tratamiento , Gadolinio , Pronóstico , Ecocardiografía , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Espectroscopía de Resonancia Magnética , Electrocardiografía/métodos
10.
J Immunol ; 207(12): 3004-3015, 2021 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-34772696

RESUMEN

Extracellular vesicles (EVs) are membrane-encapsulated nanoparticles that carry bioactive cargo, including proteins, lipids, and nucleic acids. Once taken up by target cells, EVs can modify the physiology of the recipient cells. In past studies, we reported that engagement of the glycophosphatidylinositol-anchored receptor CD24 on B lymphocytes (B cells) causes the release of EVs. However, a potential function for these EVs was not clear. Thus, we investigated whether EVs derived from CD24 or IgM-stimulated donor WEHI-231 murine B cells can transfer functional cargo to recipient cells. We employed a model system where donor cells expressing palmitoylated GFP (WEHI-231-GFP) were cocultured, after stimulation, with recipient cells lacking either IgM (WEHI-303 murine B cells) or CD24 (CD24 knockout mouse bone marrow B cells). Uptake of lipid-associated GFP, IgM, or CD24 by labeled recipient cells was analyzed by flow cytometry. We found that stimulation of either CD24 or IgM on the donor cells caused the transfer of lipids, CD24, and IgM to recipient cells. Importantly, we found that the transferred receptors are functional in recipient cells, thus endowing recipient cells with a second BCR or sensitivity to anti-CD24-induced apoptosis. In the case of the BCR, we found that EVs were conclusively involved in this transfer, whereas in the case in the CD24 the involvement of EVs is suggested. Overall, these data show that extracellular signals received by one cell can change the sensitivity of neighboring cells to the same or different stimuli, which may impact B cell development or activation.


Asunto(s)
Vesículas Extracelulares , Receptores de Antígenos de Linfocitos B , Animales , Linfocitos B/metabolismo , Vesículas Extracelulares/metabolismo , Inmunoglobulina M/metabolismo , Lípidos , Ratones , Receptores de Antígenos de Linfocitos B/metabolismo
11.
Circulation ; 144(19): 1543-1552, 2021 11 09.
Artículo en Inglés | MEDLINE | ID: mdl-34459659

RESUMEN

BACKGROUND: Percutaneous closure of the left atrial appendage (LAA) is an alternative to chronic oral anticoagulation to reduce stroke risk in patients with nonvalvular atrial fibrillation. The Amulet IDE trial (Amplatzer Amulet Left Atrial Appendage Occluder IDE Trial) was designed to evaluate the safety and effectiveness of the dual-seal mechanism of the Amulet LAA occluder compared with the Watchman device. METHODS: Patients with nonvalvular atrial fibrillation at increased risk of stroke were randomly assigned (1:1) to undergo percutaneous implantation of a LAA occluder with the Amulet occluder or Watchman device. The primary end points included safety (composite of procedure-related complications, all-cause death, or major bleeding at 12 months), effectiveness (composite of ischemic stroke or systemic embolism at 18 months), and the rate of LAA occlusion at 45 days. Prespecified secondary end points included a composite of all stroke, systemic embolism, or cardiovascular/unexplained death at 18 months, major bleeding at 18 months, and superiority test of the 3 primary end points. RESULTS: A total of 1878 patients were enrolled. The Amulet occluder was noninferior to the Watchman device for the primary safety end point (14.5% versus 14.7%; difference=-0.14 [95% CI, -3.42 to 3.13]; P<0.001 for noninferiority). Major bleeding and all-cause death were similar between groups (10.6% versus 10.0% and 3.9% versus 5.1%, respectively). Procedure-related complications were higher for the Amulet occluder (4.5% versus 2.5%), largely related to more frequent pericardial effusion and device embolization. The Amulet occluder was noninferior to the Watchman device for the primary effectiveness end point (2.8% versus 2.8%; difference=0.00 [95% CI, -1.55 to 1.55]; P<0.001 for noninferiority), and the composite of stroke, systemic embolism, or cardiovascular/unexplained death (5.6% versus 7.7%, difference=-2.12 [95% CI, -4.45 to 0.21]; P<0.001 for noninferiority). The rate of major bleeding was similar between groups (11.6% versus 12.3%; difference=-0.71 [95% CI, -3.72 to 2.31]; P=0.32 for superiority). LAA occlusion was higher for the Amulet occluder than for the Watchman device (98.9% versus 96.8%; difference=2.03 [95% CI, 0.41-3.66]; P<0.001 for noninferiority; P=0.003 for superiority). CONCLUSIONS: The Amulet occluder was noninferior for safety and effectiveness of stroke prevention for nonvalvular atrial fibrillation compared with the Watchman device and superior for LAA occlusion. Procedure-related complications were higher with the Amulet occluder and decreased with operator experience. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02879448.


Asunto(s)
Dispositivo Oclusor Septal/normas , Accidente Cerebrovascular/terapia , Anciano , Femenino , Humanos , Masculino
12.
Circulation ; 143(1): 7-17, 2021 01 05.
Artículo en Inglés | MEDLINE | ID: mdl-33073614

RESUMEN

BACKGROUND: The subcutaneous (S) implantable cardioverter-defibrillator (ICD) is safe and effective for sudden cardiac death prevention. However, patients in previous S-ICD studies had fewer comorbidities, had less left ventricular dysfunction, and received more inappropriate shocks (IAS) than in typical transvenous ICD trials. The UNTOUCHED trial (Understanding Outcomes With the S-ICD in Primary Prevention Patients With Low Ejection Fraction) was designed to evaluate the IAS rate in a more typical, contemporary ICD patient population implanted with the S-ICD using standardized programming and enhanced discrimination algorithms. METHODS: Primary prevention patients with left ventricular ejection fraction ≤35% and no pacing indications were included. Generation 2 or 3 S-ICD devices were implanted and programmed with rate-based therapy delivery for rates ≥250 beats per minute and morphology discrimination for rates ≥200 and <250 beats per minute. Patients were followed for 18 months. The primary end point was the IAS-free rate compared with a 91.6% performance goal, derived from the results for the ICD-only patients in the MADIT-RIT study (Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy). Kaplan-Meier analyses were performed to evaluate event-free rates for IAS, all-cause shock, and complications. Multivariable proportional hazard analysis was performed to determine predictors of end points. RESULTS: S-ICD implant was attempted in 1116 patients, and 1111 patients were included in postimplant follow-up analysis. The cohort had a mean age of 55.8±12.4 years, 25.6% were women, 23.4% were Black, 53.5% had ischemic heart disease, 87.7% had symptomatic heart failure, and the mean left ventricular ejection fraction was 26.4±5.8%. Eighteen-month freedom from IAS was 95.9% (lower confidence limit, 94.8%). Predictors of reduced incidence of IAS were implanting the most recent generation of device, using the 3-incision technique, no history of atrial fibrillation, and ischemic cause. The 18-month all-cause shock-free rate was 90.6% (lower confidence limit, 89.0%), meeting the prespecified performance goal of 85.8%. Conversion success rate for appropriate, discrete episodes was 98.4%. Complication-free rate at 18 months was 92.7%. CONCLUSIONS: This study demonstrates high efficacy and safety with contemporary S-ICD devices and programming despite the relatively high incidence of comorbidities in comparison with earlier S-ICD trials. The inappropriate shock rate (3.1% at 1 year) is the lowest reported for the S-ICD and lower than many transvenous ICD studies using contemporary programming to reduce IAS. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02433379.


Asunto(s)
Arritmias Cardíacas/prevención & control , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/normas , Prevención Primaria/métodos , Volumen Sistólico/fisiología , Adulto , Anciano , Arritmias Cardíacas/fisiopatología , Estudios de Cohortes , Muerte Súbita Cardíaca/epidemiología , Desfibriladores/normas , Desfibriladores/tendencias , Desfibriladores Implantables/tendencias , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
13.
Europace ; 24(7): 1058-1064, 2022 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-35061877

RESUMEN

AIMS: There is uncertainty about whether and how to perform screening for atrial fibrillation (AF). To estimate the incidence of previously undetected AF that would be captured using a continuous 14-day ECG monitor and the associated risk of stroke. METHODS AND RESULTS: We analysed data from a cohort of patients >65 years old with hypertension and a pacemaker, but without known AF. For each participant, we simulated 1000 ECG monitors by randomly selecting 14-day windows in the 6 months following enrolment and calculated the average AF burden (total time in AF). We used Cox proportional hazards models adjusted for CHA2DS2-VASc score to estimate the risk of subsequent ischaemic stroke or systemic embolism (SSE) associated with burdens of AF > and <6 min. Among 2470 participants, the median CHA2DS2-VASc score was 4.0, and 44 patients experienced SSE after 6 months following enrolment. The proportion of participants with an AF burden >6 min was 3.10% (95% CI 2.53-3.72). This was consistent across strata of age and CHA2DS2-VASc scores. Over a mean follow-up of 2.4 years, the rate of SSE among patients with <6 min of AF was 0.70%/year, compared to 2.18%/year (adjusted HR 3.02; 95% CI 1.39-6.56) in those with >6 min of AF. CONCLUSIONS: Approximately 3% of individuals aged >65 years with hypertension may have more than 6 min of AF detected by a 14-day ECG monitor. This is associated with a stroke risk of over 2% per year. Whether oral anticoagulation will reduce stroke in these patients is unknown.


Asunto(s)
Fibrilación Atrial , Isquemia Encefálica , Hipertensión , Accidente Cerebrovascular , Anciano , Anticoagulantes , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Isquemia Encefálica/diagnóstico , Electrocardiografía , Humanos , Hipertensión/diagnóstico , Hipertensión/epidemiología , Incidencia , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología
14.
Europace ; 24(1): 165-172, 2022 01 04.
Artículo en Inglés | MEDLINE | ID: mdl-34455442

RESUMEN

AIMS: To develop a suite of quality indicators (QIs) for the evaluation of the care and outcomes for adults undergoing cardiac pacing. METHODS AND RESULTS: Under the auspice of the Clinical Practice Guideline Quality Indicator Committee of the European Society of Cardiology (ESC), the Working Group for cardiac pacing QIs was formed. The Group comprised Task Force members of the 2021 ESC Clinical Practice Guidelines on Cardiac Pacing and Cardiac Resynchronization Therapy, members of the European Heart Rhythm Association, international cardiac device experts, and patient representatives. We followed the ESC methodology for QI development, which involved (i) the identification of the key domains of care by constructing a conceptual framework of the management of patients receiving cardiac pacing, (ii) the development of candidate QIs by conducting a systematic review of the literature, (iii) the selection of the final set of QIs using a modified-Delphi method, and (iv) the evaluation of the feasibility of the developed QIs. Four domains of care were identified: (i) structural framework, (ii) patient assessment, (iii) pacing strategy, and (iv) clinical outcomes. In total, seven main and four secondary QIs were selected across these domains and were embedded within the 2021 ESC Guidelines on Cardiac Pacing and Cardiac Resynchronization therapy. CONCLUSION: By way of a standardized process, 11 QIs for cardiac pacing were developed. These indicators may be used to quantify adherence to guideline-recommended clinical practice and have the potential to improve the care and outcomes of patients receiving cardiac pacemakers.


Asunto(s)
Terapia de Resincronización Cardíaca , Cardiología , Marcapaso Artificial , Adulto , Comités Consultivos , Terapia de Resincronización Cardíaca/efectos adversos , Humanos , Indicadores de Calidad de la Atención de Salud
15.
Proc Natl Acad Sci U S A ; 116(33): 16326-16331, 2019 08 13.
Artículo en Inglés | MEDLINE | ID: mdl-31366629

RESUMEN

Phase separation drives numerous cellular processes, ranging from the formation of membrane-less organelles to the cooperative assembly of signaling proteins. Features such as multivalency and intrinsic disorder that enable condensate formation are found not only in cytosolic and nuclear proteins, but also in membrane-associated proteins. The ABC transporter Rv1747, which is important for Mycobacterium tuberculosis (Mtb) growth in infected hosts, has a cytoplasmic regulatory module consisting of 2 phosphothreonine-binding Forkhead-associated domains joined by an intrinsically disordered linker with multiple phospho-acceptor threonines. Here we demonstrate that the regulatory modules of Rv1747 and its homolog in Mycobacterium smegmatis form liquid-like condensates as a function of concentration and phosphorylation. The serine/threonine kinases and sole phosphatase of Mtb tune phosphorylation-enhanced phase separation and differentially colocalize with the resulting condensates. The Rv1747 regulatory module also phase-separates on supported lipid bilayers and forms dynamic foci when expressed heterologously in live yeast and M. smegmatis cells. Consistent with these observations, single-molecule localization microscopy reveals that the endogenous Mtb transporter forms higher-order clusters within the Mycobacterium membrane. Collectively, these data suggest a key role for phase separation in the function of these mycobacterial ABC transporters and their regulation via intracellular signaling.


Asunto(s)
Transportadoras de Casetes de Unión a ATP/genética , Proteínas de la Membrana/genética , Mycobacterium tuberculosis/genética , Tuberculosis/genética , Transportadoras de Casetes de Unión a ATP/química , Citosol/metabolismo , Regulación Bacteriana de la Expresión Génica/genética , Humanos , Membrana Dobles de Lípidos/metabolismo , Proteínas de la Membrana/ultraestructura , Mycobacterium smegmatis/genética , Mycobacterium smegmatis/patogenicidad , Mycobacterium tuberculosis/patogenicidad , Mycobacterium tuberculosis/ultraestructura , Proteínas Nucleares/genética , Fosforilación/genética , Transducción de Señal/genética , Imagen Individual de Molécula , Tuberculosis/microbiología
16.
Am Heart J ; 235: 158-162, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33596412

RESUMEN

The WiSE system is a novel, leadless endocardial system that can provide cardiac resynchronization therapy in patients who cannot be treated with a conventional epicardial left ventricular lead. Safety and efficacy were being evaluated in the pivotal, randomized, double-blind SOLVE-CRT Trial (Stimulation of the Left Ventricular Endocardium for Cardiac Resynchronization Therapy.) The trial was initiated in 2018; however, patient enrollment was significantly impacted by the COVID-19 pandemic necessitating a change in design. This article describes the revised trial and the scientific rationale for the specific changes in the protocol.


Asunto(s)
COVID-19/epidemiología , Terapia de Resincronización Cardíaca/métodos , Endocardio , Insuficiencia Cardíaca/terapia , Pandemias , Terapia de Resincronización Cardíaca/efectos adversos , Método Doble Ciego , Humanos , Estudios Prospectivos , Tamaño de la Muestra , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda
17.
J Cardiovasc Electrophysiol ; 32(9): 2432-2440, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34324239

RESUMEN

BACKGROUND: Catheter ablation (CA) is a common treatment for atrial fibrillation (AF). This study evaluated outcomes of same day discharge (SDD) versus overnight stay (ONS) among AF patients undergoing outpatient CA. METHODS: The Optum SES Clinformatics Extended Data Mart database was used to identify patients ≥18 years of age undergoing outpatient CA for AF (2016-2020). Eligible patients were indexed to the date of first CA and classified into SDD and ONS groups based on the length of service. A 1:3 propensity score matching was used to create comparable SDD:ONS samples. The primary safety outcome was CA-related complications within 30 days of index procedure. The primary efficacy outcome was AF recurrence within 1 year. Cox proportional hazards models were estimated for outcome comparison. RESULTS: In the postmatch 30-day cohort for safety evaluation, there were 6600 patients (1660 [25.2%] SDD; 4940 [74.8%] ONS), with a mean age of 66.6 years. There was no significant difference in the 30-day composite rate of postablation complications (4.7% [78/1660] vs. 3.8% [187/4940]; p = 0.100) and 1-year composite rate of AF recurrence (14.3% [142/996] vs. 14.5% [430/2972]; p = 0.705) between the SDD and ONS groups. CONCLUSION: This study demonstrated that SDD following CA to treat patients with AF is safe, with low rates of postablation complications and AF recurrence, which were comparable to rates in patients with an ONS after CA.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Humanos , Alta del Paciente , Modelos de Riesgos Proporcionales , Recurrencia , Resultado del Tratamiento
18.
J Cardiovasc Electrophysiol ; 32(9): 2498-2503, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34245479

RESUMEN

BACKGROUND: Pacing at sites of late intraventricular activation (QLV) or long interventricular conduction (right ventricle [RV]-left ventricular [LV]) have been associated with improved cardiac resynchronization therapy (CRT) outcomes. Quadripolar leads improve CRT outcomes by allowing for electrical repositioning to optimize pacing sites. However, little is known regarding the effect of such repositioning on electrical delay. OBJECTIVE: Determine the relationship between different electrical bipoles from a quadripolar lead and measures of electrical delay. METHODS: Forty-six patients underwent CRT with a quadripolar lead. The RV-LV and QLV intervals were measured for both the proximal and distal bipoles and the difference (Δ) between bipoles for each measure were calculated. Multivariate analyses were performed to identify predictors of electrical delays. RESULTS: This was a typical CRT population with a mean age of 65 years and ejection fraction of 27%, with left bundle branch block (LBBB) present in 70%. The regression model for ΔQLV was significant (p = .05), with both gender (p = .008) and LBBB status (p = .020) significant predictors. The overall regression model for ΔRV-LV was not significant. ΔQLV and ΔRV-LV were significant among LBBB patients. Among non-LBBB, only ΔRV-LV was significant (mean: 7.2 ms, p = .006). ΔRV-LV versus ΔQLV were strongly correlated in LBBB (R2 = .92) but not non-LBBB (R2 = .06). CONCLUSION: In LBBB, ΔRV-LV and ΔQLV are closely correlated suggesting that the proximal bipole and thus basal LV pacing sites should be selected when feasible. Greater variation in activation pattern is present in non-LBBB, so pacing sites should be individualized.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Anciano , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/terapia , Electrocardiografía , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos , Humanos
19.
J Cardiovasc Electrophysiol ; 32(4): 1077-1084, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33650717

RESUMEN

INTRODUCTION: Catheter ablation (CA) of frequent premature ventricular contractions (PVC) is increasingly performed in older patients as the population ages. The aim of this study was to assess the impact of age on procedural characteristics, safety and efficacy on PVC ablations. METHODS: Consecutive patients with symptomatic PVCs undergoing CA between 2015 and 2020 were evaluated. Acute ablation success was defined as the elimination of PVCs at the end of the procedure. Sustained success was defined as an elimination of symptoms, and ≥80% reduction of PVC burden determined by Holter-electrocardiogram during long-term follow. Patients were sub-grouped based on age (<65 vs. ≥65 years). RESULTS: A total of 114 patients were enrolled (median age 64 years, 71% males) and followed up for a median duration of 228 days. Baseline and procedural data were similar in both age groups. A left-sided origin of PVCs was more frequently observed in the elderly patient group compared to younger patients (83% vs. 67%; p = .04). The median procedure time was significantly shorter in elderly patients (160 vs. 193 min; p = .02). The rates of both acute (86% vs. 92%; p = .32) and sustained success (70% vs. 71%; p = .90) were similar between groups. Complications rates (3.7%) did not differ between the two groups. CONCLUSION: In a large series of patients with a variety of underlying arrhythmia substrates, similar rates of acute procedural success, complications, and ventricular arrhythmia-free-survival were observed after CA of PVCs. Older age alone should not be a reason to withhold CA of PVCs.


Asunto(s)
Ablación por Catéter , Complejos Prematuros Ventriculares , Anciano , Ablación por Catéter/efectos adversos , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/cirugía
20.
J Cardiovasc Electrophysiol ; 32(3): 792-801, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33492734

RESUMEN

BACKGROUND: Traditionally, implantation of the subcutaneous implantable cardioverter defibrillator (S-ICD) requires incisions near the lateral chest wall, the xyphoid, and the superior sternal region (three-incision technique [3IT]). A two-incision technique (2IT) avoids the superior incision and has been shown to be a viable alternative in small studies with limited follow-up. OBJECTIVES: To report on the long-term safety and efficacy of the 2IT compared to the 3IT procedure in a large patient cohort. METHODS: Patients enrolled in the S-ICD post approval study (PAS) were stratified by procedural technique (2IT vs. 3IT). Baseline demographics, comorbidities and procedural outcomes were collected. Complications and S-ICD effectiveness in treating ventricular arrhythmias through an average 3-year follow-up period were compared. RESULTS: Of 1637 patients enrolled in the S-ICD PAS, 854 pts (52.2%) were implanted using the 2IT and 782 were implanted using the 3IT (47.8%). The 2IT became more prevalent over time, increasing from 40% to 69% of implants (Q1-Q4). Mean procedure time was shorter with 2IT (69.0 vs. 86.3 min, p < .0001). No other differences in outcomes were observed between the two groups, including rates of infection, electrode migration, inappropriate shocks and first shock efficacy for treating ventricular arrhythmias. CONCLUSION: In this large cohort of patients implanted with an S-ICD and followed for 3 years the 2IT was as safe and effective as the 3IT while significantly reducing procedure time.


Asunto(s)
Arritmias Cardíacas , Desfibriladores Implantables , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Estudios de Cohortes , Comorbilidad , Humanos , Implantación de Prótesis/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA