Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
J Nanobiotechnology ; 19(1): 167, 2021 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-34082783

RESUMEN

Liposomes are widely used as drug delivery carriers and as cell model systems. Here, we measure the dielectric properties of individual liposomes adsorbed on a metal electrode by in-liquid scanning dielectric microscopy in force detection mode. From the measurements the lamellarity of the liposomes, the separation between the lamellae and the specific capacitance of the lipid bilayer can be obtained. As application we considered the case of non-extruded DOPC liposomes with radii in the range ~ 100-800 nm. Uni-, bi- and tri-lamellar liposomes have been identified, with the largest population corresponding to bi-lamellar liposomes. The interlamellar separation in the bi-lamellar liposomes is found to be below ~ 10 nm in most instances. The specific capacitance of the DOPC lipid bilayer is found to be ~ 0.75 µF/cm2 in excellent agreement with the value determined on solid supported planar lipid bilayers. The lamellarity of the DOPC liposomes shows the usual correlation with the liposome's size. No correlation is found, instead, with the shape of the adsorbed liposomes. The proposed approach offers a powerful label-free and non-invasive method to determine the lamellarity and dielectric properties of single liposomes.


Asunto(s)
Portadores de Fármacos , Liposomas/química , Microscopía , Sistemas de Liberación de Medicamentos , Membrana Dobles de Lípidos , Nanotecnología/métodos
2.
Langmuir ; 36(43): 12963-12972, 2020 11 03.
Artículo en Inglés | MEDLINE | ID: mdl-33084346

RESUMEN

The specific capacitance of biological membranes is a key physical parameter in bioelectricity that also provides valuable physicochemical information on composition, phase, or hydration properties. Cholesterol is known to modulate the physicochemical properties of biomembranes, but its effect on the specific capacitance has not been fully established yet. Here we use the high spatial resolution capabilities of in-liquid scanning dielectric microscopy in force detection mode to directly demonstrate that DOPC bilayer patches at 50% cholesterol concentration show a strong reduction of their specific capacitance with respect to pure DOPC bilayer patches. The reduction observed (∼35%) cannot be explained by the small increase in bilayer thickness (∼16%). We suggest that the reduction of the specific capacitance might be due to the dehydration of the polar head groups caused by the insertion of cholesterol molecules in the bilayer. The results reported confirm the potential of in-liquid SDM to study the electrical and physicochemical properties of lipid bilayers at very small scales (down to ∼200 nm here), with implications in fields such as biophysics, bioelectricity, biochemistry, and biosensing.

3.
Phys Chem Chem Phys ; 19(5): 3884-3893, 2017 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-28106185

RESUMEN

We obtained maps of electric permittivity at ∼19 GHz frequencies on non-planar thin film heterogeneous samples by means of combined atomic force-scanning microwave microscopy (AFM-SMM). We show that the electric permittivity maps can be obtained directly from the capacitance images acquired in contact mode, after removing the topographic cross-talk effects. This result demonstrates the possibility of identifying the electric permittivity of different materials in a thin film sample irrespectively of their thickness by just direct imaging and processing. We show, in addition, that quantitative maps of the electric permittivity can be obtained with no need for any theoretical calculation or complex quantification procedures when the electric permittivity of one of the materials is known. To achieve these results the use of contact mode imaging is a key factor. For non-contact imaging modes the effects of local sample thickness and of the imaging distance make the interpretation of the capacitance images in terms of the electric permittivity properties of the materials much more complex. The present results represent a substantial contribution to the field of nanoscale microwave dielectric characterization of thin film materials with important implications for the characterization of novel 3D electronic devices and 3D nanomaterials.

4.
Proc Natl Acad Sci U S A ; 111(35): E3624-30, 2014 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-25136104

RESUMEN

The electric polarizability of DNA, represented by the dielectric constant, is a key intrinsic property that modulates DNA interaction with effector proteins. Surprisingly, it has so far remained unknown owing to the lack of experimental tools able to access it. Here, we experimentally resolved it by detecting the ultraweak polarization forces of DNA inside single T7 bacteriophages particles using electrostatic force microscopy. In contrast to the common assumption of low-polarizable behavior like proteins (εr ∼ 2-4), we found that the DNA dielectric constant is ∼ 8, considerably higher than the value of ∼ 3 found for capsid proteins. State-of-the-art molecular dynamic simulations confirm the experimental findings, which result in sensibly decreased DNA interaction free energy than normally predicted by Poisson-Boltzmann methods. Our findings reveal a property at the basis of DNA structure and functions that is needed for realistic theoretical descriptions, and illustrate the synergetic power of scanning probe microscopy and theoretical computation techniques.


Asunto(s)
Bacteriófago T7/genética , Cápside/química , ADN Viral/química , ADN/química , Espectroscopía Dieléctrica/métodos , Modelos Químicos , Bacteriófago T7/química , Cationes/química , ADN/metabolismo , ADN Viral/metabolismo , Proteínas de Unión al ADN/química , Técnicas Electroquímicas , Ligandos , Microscopía de Fuerza Atómica , Proteínas Nucleares/química , Proteínas Nucleares/metabolismo
5.
Adv Mater ; 36(13): e2309767, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38110297

RESUMEN

Charge transport in electrolyte-gated organic field-effect transistors (EGOFETs) is governed by the microstructural property of the semiconducting thin film that is in direct contact with the electrolyte. Therefore, a comprehensive nanoscale operando characterization of the active channel is crucial to pinpoint various charge transport bottlenecks for rational and targeted optimization of the devices. Here, the local electrical properties of EGOFETs are systematically probed by in-liquid scanning dielectric microscopy (in-liquid SDM) and a direct picture of their functional mechanism at the nanoscale is provided across all operational regimes, starting from subthreshold, linear to saturation, until the onset of pinch-off. To this end, a robust interpretation framework of in-liquid SDM is introduced that enables quantitative local electric potential mapping directly from raw experimental data without requiring calibration or numerical simulations. Based on this development, a straightforward nanoscale assessment of various charge transport bottlenecks is performed, like contact access resistances, inter- and intradomain charge transport, microstructural inhomogeneities, and conduction anisotropy, which have been inaccessible earlier. Present results contribute to the fundamental understanding of charge transport in electrolyte-gated transistors and promote the development of direct structure-property-function relationships to guide future design rules.

6.
Bioelectrochemistry ; 157: 108675, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38422765

RESUMEN

Cable bacteria are filamentous, multicellular microorganisms that display an exceptional form of biological electron transport across centimeter-scale distances. Currents are guided through a network of nickel-containing protein fibers within the cell envelope. Still, the mechanism of long-range conduction remains unresolved. Here, we characterize the conductance of the fiber network under dry and wet, physiologically relevant, conditions. Our data reveal that the fiber conductivity is high (median value: 27 S cm-1; range: 2 to 564 S cm-1), does not show any redox signature, has a low thermal activation energy (Ea = 69 ± 23 meV), and is not affected by humidity or the presence of ions. These features set the nickel-based conduction mechanism in cable bacteria apart from other known forms of biological electron transport. As such, conduction resembles that of an organic semi-metal with a high charge carrier density. Our observation that biochemistry can synthesize an organo-metal-like structure opens the way for novel bio-based electronic technologies.


Asunto(s)
Bacterias , Níquel , Oxidación-Reducción , Transporte de Electrón , Bacterias/metabolismo , Conductividad Eléctrica
7.
Nat Mater ; 11(9): 808-16, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22772654

RESUMEN

Label-free detection of the material composition of nanoparticles could be enabled by the quantification of the nanoparticles' inherent dielectric response to an applied electric field. However, the sensitivity of dielectric nanoscale objects to geometric and non-local effects makes the dielectric response extremely weak. Here we show that electrostatic force microscopy with sub-piconewton resolution can resolve the dielectric constants of single dielectric nanoparticles without the need for any reference material, as well as distinguish nanoparticles that have an identical surface but different inner composition. We unambiguously identified unlabelled ~10 nm nanoparticles of similar morphology but different low-polarizable materials, and discriminated empty from DNA-containing virus capsids. Our approach should make the in situ characterization of nanoscale dielectrics and biological macromolecules possible.


Asunto(s)
Bacteriófago T7/aislamiento & purificación , Microscopía/métodos , Nanopartículas/análisis , Bacteriófago T7/química , Calibración , Cápside/química , Impedancia Eléctrica , Nanopartículas/química , Tamaño de la Partícula
8.
Colloids Surf B Biointerfaces ; 222: 113019, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36435028

RESUMEN

Drug and gene delivery systems based on polymeric nanoparticles offer a greater efficacy and a reduced toxicity compared to traditional formulations. Recent studies have evidenced that their internalization, biodistribution and efficacy can be affected, among other factors, by their mechanical properties. Here, we analyze by means of Atomic Force Microscopy force spectroscopy how composition, surface functionalization and loading affect the mechanics of nanoparticles. For this purpose, nanoparticles made of Poly(lactic-co-glycolic) (PLGA) and Ethyl cellulose (EC) with different functionalizations and loading were prepared by nano-emulsion templating using the Phase Inversion Composition method (PIC) to form the nano-emulsions. A multiparametric nanomechanical study involving the determination of the Young's modulus, maximum deformation and breakthrough force was carried out. The obtained results showed that composition, surface functionalization and loading affect the nanomechanical properties in a different way, thus requiring, in general, to consider the overall mechanical properties after the addition of a functionalization or loading. A graphical representation method has been proposed enabling to easily identify mechanically equivalent formulations, which is expected to be useful in the development of soft polymeric nanoparticles for pre-clinical and clinical use.


Asunto(s)
Nanopartículas , Ácido Poliglicólico , Copolímero de Ácido Poliláctico-Ácido Poliglicólico , Ácido Poliglicólico/química , Ácido Láctico/química , Distribución Tisular , Nanopartículas/química
9.
ACS Nano ; 16(9): 15347-15357, 2022 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-35998341

RESUMEN

Van der Waals layered ferroelectrics, such as CuInP2S6 (CIPS), offer a versatile platform for miniaturization of ferroelectric device technologies. Control of the targeted composition and kinetics of CIPS synthesis enables the formation of stable self-assembled heterostructures of ferroelectric CIPS and nonferroelectric In4/3P2S6 (IPS). Here, we use quantitative scanning probe microscopy methods combined with density functional theory (DFT) to explore in detail the nanoscale variability in dynamic functional properties of the CIPS-IPS heterostructure. We report evidence of fast ionic transport which mediates an appreciable out-of-plane electromechanical response of the CIPS surface in the paraelectric phase. Further, we map the nanoscale dielectric and ionic conductivity properties as we thermally stimulate the ferroelectric-paraelectric phase transition, recovering the local dielectric behavior during this phase transition. Finally, aided by DFT, we reveal a substantial and tunable conductivity enhancement at the CIPS/IPS interface, indicating the possibility of engineering its interfacial properties for next generation device applications.

10.
Langmuir ; 27(21): 13165-72, 2011 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-21936555

RESUMEN

Atomic force microscopy (AFM) has been used to study the structural and mechanical properties of low concentrated spin-coated dioleoylphosphatidylcholine (DOPC) layers in dry environment (RH ≈ 0%) at the nanoscale. It is shown that for concentrations in the 0.1-1 mM range the structure of the DOPC spin-coated samples consists of an homogeneous lipid monolayer ∼1.3 nm thick covering the whole substrate on top of which lipid bilayer (or multilayer) micro- and nanometric patches and rims are formed. The thickness of the bilayer structures is found to be ∼4.5 nm (or multiples of this value for multilayer structures), while the lateral dimensions range from micrometers to tens of nanometer depending on the lipid concentration. The force required to break a bilayer (breakthrough force) is found to be ∼0.24 nN. No dependence of the mechanical values on the lateral dimensions of the bilayer structures is evidenced. Remarkably, the thickness and breakthrough force values of the bilayers measured in dry environment are very similar to values reported in the literature for supported DOPC bilayers in pure water.


Asunto(s)
Membrana Dobles de Lípidos/química , Fenómenos Mecánicos , Microscopía de Fuerza Atómica , Nanotecnología , Fosfatidilcolinas/química , Silicatos de Aluminio/química , Soluciones
11.
Nanoscale ; 13(44): 18754-18762, 2021 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-34747424

RESUMEN

Shewanella oneidensis MR-1 is a metal-reducing bacterium that is able to exchange electrons with solid-phase minerals outside the cell. These bacterial cells can produce outer membrane extensions (OMEs) that are tens of nanometers wide and several microns long. The capability of these OMEs to transport electrons is currently under investigation. Tubular chemically fixed OMEs from S. oneidensis have shown good dc conducting properties when measured in an air environment. However, no direct demonstration of the conductivity of the more common bubble-like OMEs has been provided yet, due to the inherent difficulties in measuring it. In the present work, we measured the electrical properties of bubble-like OMEs in a dry air environment by Scanning Dielectric Microscopy (SDM) in force detection mode. We found that at the frequency of the measurements (∼2 kHz), OMEs show an insulating behavior, with an equivalent homogeneous dielectric constant εOME = 3.7 ± 0.7 and no dephasing between the applied ac voltage and the measured ac electric force. The dielectric constant measured for the OMEs is comparable to that obtained for insulating supramolecular protein structures (εprotein = 3-4), pointing towards a rich protein composition of the OMEs, probably coming from the periplasm. Based on the detection sensitivity of the measuring instrument, the upper limit for the ac longitudinal conductivity of bubble-like OMEs in a dry air environment has been set to σOME,ac < 10-5 S m-1, a value several orders of magnitude smaller than the dc conductivity measured in tubular chemically fixed OMEs. The lack of conductivity of bubble-like OMEs can be attributed to the relatively large separation between cytochromes in these larger OMEs and to the suppression of cytochrome mobility due to the dry environmental conditions.


Asunto(s)
Shewanella , Transporte de Electrón , Electrones , Periplasma/metabolismo
12.
Nanoscale ; 13(22): 10116-10126, 2021 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-34060583

RESUMEN

Polymer nanocomposite materials based on metallic nanowires are widely investigated as transparent and flexible electrodes or as stretchable conductors and dielectrics for biosensing. Here we show that Scanning Dielectric Microscopy (SDM) can map the depth distribution of metallic nanowires within the nanocomposites in a non-destructive way. This is achieved by a quantitative analysis of sub-surface electrostatic force microscopy measurements with finite-element numerical calculations. As an application we determined the three-dimensional spatial distribution of ∼50 nm diameter silver nanowires in ∼100 nm-250 nm thick gelatin films. The characterization is done both under dry ambient conditions, where gelatin shows a relatively low dielectric constant, εr∼ 5, and under humid ambient conditions, where its dielectric constant increases up to εr∼ 14. The present results show that SDM can be a valuable non-destructive subsurface characterization technique for nanowire-based nanocomposite materials, which can contribute to the optimization of these materials for applications in fields such as wearable electronics, solar cell technologies or printable electronics.

13.
Nanomaterials (Basel) ; 11(6)2021 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-34070690

RESUMEN

Mapping the dielectric properties of cells with nanoscale spatial resolution can be an important tool in nanomedicine and nanotoxicity analysis, which can complement structural and mechanical nanoscale measurements. Recently we have shown that dielectric constant maps can be obtained on dried fixed cells in air environment by means of scanning dielectric force volume microscopy. Here, we demonstrate that such measurements can also be performed in the much more challenging case of fixed cells in liquid environment. Performing the measurements in liquid media contributes to preserve better the structure of the fixed cells, while also enabling accessing the local dielectric properties under fully hydrated conditions. The results shown in this work pave the way to address the nanoscale dielectric imaging of living cells, for which still further developments are required, as discussed here.

14.
Small Methods ; 5(7): e2100279, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-34928004

RESUMEN

Mapping the biochemical composition of eukaryotic cells without the use of exogenous labels is a long-sought objective in cell biology. Recently, it has been shown that composition maps on dry single bacterial cells with nanoscale spatial resolution can be inferred from quantitative nanoscale dielectric constant maps obtained with the scanning dielectric microscope. Here, it is shown that this approach can also be applied to the much more challenging case of fixed and dry eukaryotic cells, which are highly heterogeneous and show micrometric topographic variations. More importantly, it is demonstrated that the main bottleneck of the technique (the long computation times required to extract the nanoscale dielectric constant maps) can be shortcut by using supervised neural networks, decreasing them from weeks to seconds in a wokstation computer. This easy-to-use data-driven approach opens the door for in situ and on-the-fly label free nanoscale composition mapping of eukaryotic cells with scanning dielectric microscopy.


Asunto(s)
Células Eucariotas , Aprendizaje Automático , Microscopía de Fuerza Atómica/métodos
15.
Nat Commun ; 12(1): 3996, 2021 06 28.
Artículo en Inglés | MEDLINE | ID: mdl-34183682

RESUMEN

Filamentous cable bacteria display long-range electron transport, generating electrical currents over centimeter distances through a highly ordered network of fibers embedded in their cell envelope. The conductivity of these periplasmic wires is exceptionally high for a biological material, but their chemical structure and underlying electron transport mechanism remain unresolved. Here, we combine high-resolution microscopy, spectroscopy, and chemical imaging on individual cable bacterium filaments to demonstrate that the periplasmic wires consist of a conductive protein core surrounded by an insulating protein shell layer. The core proteins contain a sulfur-ligated nickel cofactor, and conductivity decreases when nickel is oxidized or selectively removed. The involvement of nickel as the active metal in biological conduction is remarkable, and suggests a hitherto unknown form of electron transport that enables efficient conduction in centimeter-long protein structures.


Asunto(s)
Proteínas Bacterianas/química , Deltaproteobacteria/metabolismo , Conductividad Eléctrica , Transporte de Electrón/fisiología , Níquel/química , Electricidad
16.
Nano Lett ; 9(4): 1604-8, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19271767

RESUMEN

We present the experimental demonstration of low-frequency dielectric constant imaging of single-layer supported biomembranes at the nanoscale. The dielectric constant image has been quantitatively reconstructed by combining the thickness and local capacitance obtained using a scanning force microscope equipped with a sub-attofarad low-frequency capacitance detector. This work opens new possibilities for studying bioelectric phenomena and the dielectric properties of biological membranes at the nanoscale.


Asunto(s)
Membrana Celular , Microscopía/métodos , Nanotecnología
17.
Nanoscale ; 12(40): 20658-20668, 2020 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-33043923

RESUMEN

Organic self-assembled monolayers (SAMs) at metal/electrolyte interfaces have been thoroughly investigated both from fundamental and applied points of view. A relevant figure of merit of metal/SAM/electrolyte interfaces is the specific capacitance, which determines the charge that can be accumulated at the metal electrode. Here, we show that the specific capacitance of non-uniform alkanethiol SAMs at gold/electrolyte interfaces can be quantitatively measured and mapped at the nanoscale by in-liquid scanning dielectric microscopy in force detection mode. We show that sub-100 nm spatial resolution in ultrathin (<1 nm) SAMs can be achieved, largely improving the performance of current sensing characterization techniques. The present results provide access to study the dielectric properties of metal/SAM/electrolyte interfaces at scales that have remained unexplored until now.

18.
Biosens Bioelectron ; 150: 111844, 2020 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-31740253

RESUMEN

Organic electronic materials offer an untapped potential for novel tools for low-invasive electrophysiological recording and stimulation devices. Such materials combine semiconducting properties with tailored surface chemistry, elastic mechanical properties and chemical stability in water. In this work, we investigate solution processed Electrolyte Gated Organic Field Effect Transistors (EGOFETs) based on a small molecule semiconductor. We demonstrate that EGOFETs based on a blend of soluble organic semiconductor 2,8-Difluoro-5,11-bis(triethylsilylethynyl)anthradithiophene (diF-TES-ADT) combined with an insulating polymer show excellent sensitivity and long-term recording under electrophysiological applications. Our devices can stably record the extracellular potential of human pluripotent stem cell derived cardiomyocyte cells (hPSCs-CMs) for several weeks. In addition, cytotoxicity tests of pharmaceutical drugs, such as Norepinephrine and Verapamil was achieved with excellent sensitivity. This work demonstrates that organic transistors based on organic blends are excellent bioelectronics transducer for extracellular electrical recording of excitable cells and tissues thus providing a valid alternative to electrochemical transistors.


Asunto(s)
Técnicas Biosensibles , Electrólitos/aislamiento & purificación , Miocitos Cardíacos/metabolismo , Electrodos , Electrólitos/química , Fenómenos Electrofisiológicos , Humanos , Miocitos Cardíacos/química , Polímeros/química , Semiconductores , Transistores Electrónicos , Agua/química
19.
Nanoscale ; 11(43): 20809-20819, 2019 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-31657419

RESUMEN

Mapping the dielectric constant at the nanoscale of samples showing a complex topography, such as non-planar nanocomposite materials or single cells, poses formidable challenges to existing nanoscale dielectric microscopy techniques. Here we overcome these limitations by introducing Scanning Dielectric Force Volume Microscopy. This scanning probe microscopy technique is based on the acquisition of electrostatic force approach curves at every point of a sample and its post-processing and quantification by using a computational model that incorporates the actual measured sample topography. The technique provides quantitative nanoscale images of the local dielectric constant of the sample with unparalleled accuracy, spatial resolution and statistical significance, irrespectively of the complexity of its topography. We illustrate the potential of the technique by presenting a nanoscale dielectric constant map of a single bacterial cell, including its small-scale appendages. The bacterial cell shows three characteristic equivalent dielectric constant values, namely, εr,bac1 = 2.6 ± 0.2, εr,bac2 = 3.6 ± 0.4 and εr,bac3 = 4.9 ± 0.5, which enable identifying different dielectric properties of the cell wall and of the cytoplasmatic region, as well as, the existence of variations in the dielectric constant along the bacterial cell wall itself. Scanning Dielectric Force Volume Microscopy is expected to have an important impact in Materials and Life Sciences where the mapping of the dielectric properties of samples showing complex nanoscale topographies is often needed.


Asunto(s)
Capacidad Eléctrica , Microscopía de Fuerza Atómica/métodos , Pseudomonas aeruginosa/química , Pared Celular/química , Microesferas , Nanotecnología , Pseudomonas aeruginosa/metabolismo , Dióxido de Silicio/química , Propiedades de Superficie
20.
Biosens Bioelectron ; 24(2): 290-6, 2008 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-18511254

RESUMEN

This article presents the fabrication and characterisation of a high-speed detection micro-Coulter counter with two-dimensional (2D) adjustable aperture and differential impedance detection. The developed device has been fabricated from biocompatible and transparent materials (polymer and glass) and uses the principle of hydrodynamic focusing in two dimensions. The use of a conductive solution for the sample flux and non-conductive solutions for the focalising fluxes provides an adjustable sample flow where particles are aligned and the resistive response concentrated, consequently enhancing the sensitivity and versatility of the device. High-speed counting of 20 microm polystyrene particles and 5 microm yeast cells with a rate of up to 1,000 particles/s has been demonstrated. Two-dimensional focusing conditions have been used in devices with physical cross-sectional areas of 180 microm x 65 microm and 100 microm x 43 microm, respectively, in which particles resulted undetectable in the absence of focusing. The 2D-focusing conditions have provided, in addition, increased detection sensitivity by a factor of 1.6 as compared to 1D-focusing conditions.


Asunto(s)
Recuento de Células/instrumentación , Electrónica/instrumentación , Citometría de Flujo/instrumentación , Técnicas Analíticas Microfluídicas/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA