Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Sensors (Basel) ; 23(11)2023 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-37299937

RESUMEN

We present a device- and network-based solution for automatic passnger counting that operates on the edge in real time. The proposed solution consists of a low-cost WiFi scanner device equipped with custom algorithms for dealing with MAC address randomization. Our low-cost scanner is able to capture and analyze 802.11 probe requests emitted by passengers' devices such as laptops, smartphones, and tablets. The device is configured with a Python data-processing pipeline that combines data coming from different types of sensors and processes them on the fly. For the analysis task, we have devised a lightweight version of the DBSCAN algorithm. Our software artifact is designed in a modular way in order to accommodate possible extensions of the pipeline, e.g., either additional filters or data sources. Furthermore, we exploit multi-threading and multi-processing for speeding up the entire computation. The proposed solution has been tested with different types of mobile devices, obtaining promising experimental results. In this paper, we present the key ingredients of our edge computing solution.

2.
J Pediatr Hematol Oncol ; 37(4): 311-4, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25811747

RESUMEN

BACKGROUND: Sickle cell disease (SCD) is a well-known multisystem illness characterized by vascular injury due to vasoocclusion and hemolysis, as well as infectious complications and iron overload, all of which contribute to high morbidity and mortality rates among children. In these patients, some authors have previously described iron cortical deposition in the kidney. We here report the first case in the literature of a girl affected by SCD showing an anomalous metal and rare element retention in the renal cortex. CASE PRESENTATION: A 10-year-old white girl affected by SCD underwent a routine magnetic resonance imaging investigation that evidenced a reduced signal intensity in the renal cortex, compatible with hemosiderin precipitation. Histologic and elemental analyses of the hepatic and the renal biotic samples, performed with inductively coupled plasma mass spectrometry, revealed that concomitant with the high iron deposition, toxic and potentially carcinogenic elements such as nickel, magnesium, rubidium, and gadolinuim were anomalously retained particularly in the kidney. CONCLUSIONS: The finding of rare and toxic elements in the kidney of SCD patients might be linked to the development of specific neoplastic transformations already described in this patient cohort. To be confirmed, our speculations need to be demonstrated in large sampling of patients.


Asunto(s)
Anemia de Células Falciformes/metabolismo , Corteza Renal/metabolismo , Metales/metabolismo , Niño , Femenino , Humanos , Espectrofotometría Atómica
3.
BMC Health Serv Res ; 14: 327, 2014 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-25070705

RESUMEN

BACKGROUND: The growing cost of health care and lack of specialised staff have set e-Health high on the European political agenda. In a prospective study we evaluated the effect of providing images for remote consultation through an iPad on the number of in-hospital orthopaedic consultations for children with bone fractures. METHODS: Children from 0 to 18 years diagnosed with a bone fracture by the radiologist during the hours when an orthopaedic service is provided only on-call were eligible for enrollment. Cases were enrolled prospectively during September and October 2013. A standard approach (verbal information only, no X-Ray provided remotely) was compared to an experimental approach (standard approach plus the provision of X-ray for remote consultation through an iPad). The primary outcome was the number of orthopaedic in-hospital consultations that occurred. Other outcomes included: immediate activation of other services; time needed for decision-making; technical difficulties; quality of images and diagnostic confidence (on a likert scale of 1 to 10). RESULTS: Forty-two children were enrolled in the study. Number of in-hospital consultancies dropped from 32/42 (76.1%) when no X-ray was provided to 16/42 (38%) when the X-rays was provided (p < 0.001). With remote X-ray consultation in 14/42 (33.3%) cases services such as surgery and plaster room could be immediately activated, compared to no service activated without teleradiology (p < 0.001). Average time for decision making was 23.4 ± 21.8 minutes with remote X-ray consultation, compared to 56.2 ± 16.1 when the X-ray was not provided (p < 0.001). The comparison between images on the iPad and on the standard system for X- Ray visualisation resulted in a non statistically significant difference in the quality of images (average score 9.89 ± 0.37 vs 9.91 ± 0.30; p = 0.79), and in non statistically significant difference in diagnostic confidence (average score 9.91 ± 0.32 vs 9.92 ± 0.31; p = 0.88). CONCLUSIONS: Remote X-ray consultation through Aycan OsiriX PRO and iPad should be considered as a means for reducing the need of in-hospital orthopaedic consultation during on-call times, and potentially decrease the cost of care for the health system. In the future, alternative systems less expensive than Aycan OsiriX PRO should be further developed and tested.


Asunto(s)
Computadoras de Mano , Fracturas Óseas/diagnóstico por imagen , Consulta Remota/instrumentación , Telerradiología/instrumentación , Adolescente , Niño , Preescolar , Toma de Decisiones , Humanos , Lactante , Recién Nacido , Italia , Estudios Prospectivos , Radiografía , Factores de Tiempo
4.
PLoS One ; 14(12): e0226023, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31805135

RESUMEN

This study investigates the bottlenose dolphin (Tursiops truncatus, Montagu 1821) habitat use in the Portofino marine protected area (NW Italy) and adjacent waters, a core area for the dolphins and a highly touristic area in the Mediterranean Sea. A permanent automated real-time passive acoustic monitoring system, able to detect and track dolphins continuously, was tested in the area within the activities of the Life+ Nature project ARION. The habits of bottlenose dolphins was investigated considering the resident rate inside the area, which quantifies the amount of time dolphins spent in these waters, by means of random forest regression. The dependency of dolphin resident rate was analyzed in relation to four explanatory variables: sea surface temperature, season, time of day, and proximity to the coast. Dolphins spent more time in the area during spring and when sea surface temperature ranged between 15-16°C. Summer resulted the season with lower dolphin residency with significant difference between working day and weekend, in the last the lowest residency was recorded. Main findings provide important information to properly manage the area in order to protect bottlenose dolphins.


Asunto(s)
Acústica , Delfín Mular , Ecosistema , Monitoreo del Ambiente/métodos , Animales , Monitoreo del Ambiente/instrumentación , Análisis de Regresión , Estaciones del Año
5.
PLoS One ; 11(10): e0164539, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27749905

RESUMEN

BACKGROUND: The use of point-of-care ultrasonography (POC US) in paediatrics is increasing. This study investigated the diagnostic accuracy of POC US in children accessing the emergency department (ED) when performed by paediatricians under the remote guidance of radiologists (TELE POC). METHODS: Children aged 0 to 18 years accessing the ED of a third level research hospital with eight possible clinical scenarios and without emergency/severity signs at the triage underwent three subsequent US tests: by a paediatrician guided remotely by a radiologist (TELE POC); by the same radiologist (UNBLIND RAD); by an independent blinded radiologist (BLIND RAD). Tele-radiology was implemented using low cost "commercial off-the-shelf" (COTS) equipment and open-source software. Data were prospectively collected on predefined templates. RESULTS: Fifty-two children were enrolled, for a total of 170 ultrasound findings. Sensitivity, specificity, positive and negative predictive values of TELE POC were: 93.8, 99.7, 96.8, 99.4 when compared to UNBLIND RAD and 88.2, 99.7, 96.8, 98.7 when compared to BLIND RAD. The inter-observers agreement between the paediatricians and either the unblind or blind radiologist was excellent (k = 0.93). The mean duration of TELE POC was 6.3 minutes (95% CI 4.1 to 8.5). Technical difficulties occurred in two (3.8%) cases. Quality of the transmission was rated as fair, good, very good and excellent in 7.7%, 15.4%, 42.3% and 34.6% of cases respectively, while in no case was it rated as poor. CONCLUSIONS: POC US performed by paediatricians in ED guided via tele-radiology by an expert radiologist (TELE POC) produced reliable and timely diagnoses. Findings of this study, especially for the rarer conditions under evaluation, need further confirmation. Future research should investigate the overall benefits and the cost savings of using tele-ultrasound to perform US "at children's bedsides", under remote guidance of expert radiologists.


Asunto(s)
Errores Diagnósticos/estadística & datos numéricos , Sistemas de Atención de Punto , Práctica Profesional/estadística & datos numéricos , Consulta Remota/métodos , Ultrasonografía , Abdomen/diagnóstico por imagen , Adolescente , Niño , Preescolar , Sistemas de Computación , Servicio de Urgencia en Hospital/economía , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Consulta Remota/instrumentación , Programas Informáticos
6.
PLoS One ; 11(1): e0145362, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26789265

RESUMEN

Within the framework of the EU Life+ project named LIFE09 NAT/IT/000190 ARION, a permanent automated real-time passive acoustic monitoring system for the improvement of the conservation status of the transient and resident population of bottlenose dolphin (Tursiops truncatus) has been implemented and installed in the Portofino Marine Protected Area (MPA), Ligurian Sea. The system is able to detect the simultaneous presence of dolphins and boats in the area and to give their position in real time. This information is used to prevent collisions by diffusing warning messages to all the categories involved (tourists, professional fishermen and so on). The system consists of two gps-synchronized acoustic units, based on a particular type of marine buoy (elastic beacon), deployed about 1 km off the Portofino headland. Each one is equipped with a four-hydrophone array and an onboard acquisition system which can record the typical social communication whistles emitted by the dolphins and the sound emitted by boat engines. Signals are pre-filtered, digitized and then broadcast to the ground station via wi-fi. The raw data are elaborated to get the direction of the acoustic target to each unit, and hence the position of dolphins and boats in real time by triangulation.


Asunto(s)
Acústica/instrumentación , Delfín Mular/fisiología , Vocalización Animal/fisiología , Animales , Sistemas de Computación , Conservación de los Recursos Naturales/métodos , Mar Mediterráneo , Navíos , Espectrografía del Sonido/instrumentación , Espectrografía del Sonido/métodos
7.
Opt Lett ; 34(7): 1078-80, 2009 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-19340225

RESUMEN

A novel technique, based on polarization-sensitive, frequency-domain reflectometry, for a full noninvasive characterization of spin profile in randomly birefringent spun fibers is presented. Effective measurements of spin profile in a fiber sample a few tens of meters long are reported, but the technique can be straightforwardly scaled to kilometers-long samples.

8.
Opt Lett ; 33(20): 2284-6, 2008 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-18923597

RESUMEN

We present a novel reflectometric technique for the measurement of orientation and modulus of the linear birefringence vector in single-mode optical fibers. The technique provides information also on circular birefringence, although this component, if present, appears as a rotation of the linear birefringence. A detailed theoretical analysis is reported and validated by experimental results.

9.
Respiration ; 70(2): 179-94, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-12740516

RESUMEN

Complex technical problems interfered with the application of thoracic ultrasound (US) for studies and clinical research. Moreover, in contrast to radiologists, cardiologists, gastroenterologists, internists, obstetricians, gynecologists and others, pulmonologists were not trained in the basics of US images. However, endoscopic US methods were developed in the last 20 years and these methods also provided important results for pulmonologists. As soon as the technical problems interfering with US application in air-containing spaces were solved, endobronchial US (EBUS) became a valuable technique as well. With EBUS, the delicate multilayer structure of the tracheobronchial wall can be analyzed. This knowledge became decisive for the management of early cancer in the central airways. These lesions can undergo local treatment instead of surgical intervention if the bronchial cartilage is intact and if the adjacent lymph nodes are not involved. EBUS proved valuable as well for the staging of more advanced lung cancer, especially with regard to endoluminal, intramural and extraluminal tumor spread. Endobronchial endosonographers are able to diagnose mediastinal lymph nodes similar to the experience of gastrointestinal endosonographers. EBUS-guided transbronchial needle aspiration (TBNA) improved the results of N-staging of lung cancer, especially in difficult lymph node levels without any clear endoscopic landmarks. The possibility of identifying N2 and N3 stages by means of a nonsurgical procedure can modify the management of lung cancer and decrease the number of unnecessary surgical interventions. EBUS can reduce the need for more invasive procedures such as thoracoscopy or mediastinoscopy. It is also useful for biopsying peripheral lesions or solitary pulmonary nodules instead of fluoroscopic guidance and also plays an important role in the strategy of interventional endoscopy.


Asunto(s)
Bronquios/diagnóstico por imagen , Endosonografía , Neoplasias Pulmonares/diagnóstico , Biopsia con Aguja , Broncoscopía/métodos , Fluoroscopía , Humanos , Metástasis Linfática
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA