Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Pacing Clin Electrophysiol ; 36(5): 570-7, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23448187

RESUMEN

BACKGROUND: An implantable left atrial pressure (LAP) monitoring system for guiding the management of patients with advanced heart failure has the potential to require extraction, particularly in the setting of infection. The LAP sensor lead was designed to be suitable for ease of percutaneous extraction using standard techniques for extracting pacemaker and defibrillator leads. The clinical experience, to date, with percutaneous extraction of the LAP sensor lead is presented. METHODS: A total of 82 patients underwent successful implantation of the LAP sensor lead using transseptal catheterization. Five patients of the 82 patients during a cumulative follow-up period of 267 patient-years (median of 2.9 years/patient) underwent percutaneous extraction using manual traction with a locking stylet and/or an excimer laser sheath to bore through adhesions. The distal fixation anchors of the LAP sensor lead are designed to fold forward during extraction so that the sensor module can easily separate from the interatrial septum. RESULTS: Percutaneous extraction of the LAP sensor lead was accomplished successfully in all five patients with no embolic events, vascular tears, perforations, or other complications requiring surgical intervention. Manual traction alone was sufficient to detach the LAP sensor lead from the interatrial septum in all cases. Use of the excimer laser sheath was needed in selected cases to bore through scar tissue within the venous insertion site, but not within the heart. CONCLUSIONS: The extraction of the LAP sensor lead was accomplished safely using standard techniques and equipment for percutaneously extracting pacemaker and defibrillator leads.


Asunto(s)
Determinación de la Presión Sanguínea/instrumentación , Remoción de Dispositivos/métodos , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Insuficiencia Cardíaca/fisiopatología , Prótesis e Implantes , Transductores de Presión , Anciano , Determinación de la Presión Sanguínea/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Insuficiencia Cardíaca/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
2.
ASAIO J ; 59(5): 486-92, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23851452

RESUMEN

A left atrial pressure (LAP) monitoring system was developed for guiding the management of patients with heart failure. The LAP sensor is implanted into the left atrium via transseptal catheterization and affixed to the interatrial septum by nitinol anchors. The long-term safety of permanent implantation of the LAP sensor in patients was evaluated based on the comparative pathology in animals. Tissue specimens of the LAP sensor from 7 patients, 49 canines, and 14 ovine were examined for thrombosis and tissue overgrowth. Implant duration ranged from 22 to 1,686 days. Gross examination showed minimal-to-moderate tissue overgrowth with no evidence of migration, erosion, or perforation. There was no excessive host-to-device reaction or active thrombogenesis in any of the subjects that followed the antithrombotic therapy protocol. Micro-computed tomography scanning confirmed the structural integrity of the device. Low vacuum scanning electron microscopy and histology showed neoendocardial tissue overgrowth with no inflammation or fibrin. The pathology of both animal models was found to closely approximate the pathology in humans and favorably supports the long-term safety of the device.


Asunto(s)
Presión Atrial , Atrios Cardíacos/patología , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Transductores de Presión , Animales , Artefactos , Perros , Falla de Equipo , Insuficiencia Cardíaca/terapia , Humanos , Microscopía Electrónica de Rastreo , Modelos Animales , Seguridad del Paciente , Presión , Ovinos , Trombosis/fisiopatología , Factores de Tiempo , Microtomografía por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA