Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Langmuir ; 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-38957955

RESUMEN

The antifouling properties of conductive polymers have received extensive attention for biosensor and bioelectronic applications. Polyethylene glycol (PEG) is a well-known antifouling material, but the controlled regulation of the surface topography of PEG without a template remains a challenge. Here, we show a columnar structure antifouling conductive polymer brush with enhanced antifouling properties and considerable conductivity. The method involves synthesizing the 3,4-ethylenedioxythiophene monomer modified with azide (EDOT-N3), the electropolymerization of PEDOT-N3, and the in situ growth of PEG polymer brushes on PEDOT through double-click reactions. The resultant columnar structure polymer brush exhibits high electrical conductivity (3.5 Ω·cm2), ultrahigh antifouling property, electrochemical stability (capacitance retention was 93.8% after 2000 cycles of CV scans in serum), and biocompatibility.

2.
Inorg Chem ; 63(7): 3317-3326, 2024 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-38329889

RESUMEN

A new 3D zinc-based metal-organic framework {[Zn7L2(DMF)3(H2O)(OH)2]·5DMF}n (1) (H6L = 5,5',5″-(methylsilanetriyl) triisophthalic acid) was constructed with an organosilicon-based linker, where H6L is a tetrahedral structure furnished with rich -COO- chelating sites for Zn(II) immobilization. Compound 1 exhibited two types of irregular one-dimensional channels and a three-dimensional skeleton with large specific surface area, making it a promising catalytic platform. Moreover, by incorporation of the second metal ion into the inorganic node of framework 1, isomorphic bimetallic MOF ZnMg-1 was successfully synthesized. ZnMg-1 demonstrated enhanced catalytic activity compared to 1 under identical conditions. Contrast experiments and theoretical calculations indicate that bimetallic active sites play a facilitating role in the chemical fixation of epoxides and CO2. It indicated that efficient chemical fixation of CO2 to cyclic carbonates was obtained over isomorphic MOF catalysts 1 and ZnMg-1.

3.
Mikrochim Acta ; 191(5): 257, 2024 04 11.
Artículo en Inglés | MEDLINE | ID: mdl-38600405

RESUMEN

A new detection platform based on CaCO3-based magnetic micromotor (CaCO3@Fe3O4) integrated with graphene field effect transistor (GFET) was construct and used for on-site SARS-CoV-2 coronavirus pathogen detection. The CaCO3@Fe3O4 micromotor, which was modified with anti-SARS-CoV-2 (labelled antibody, AntiE1), can self-moved in the solution containing hydrochloric acid (HCl) and effective to capture the SARS-CoV-2 coronavirus pathogens. After magnetic field separation, the capture micromotor was detected by GFET, exhibiting a good linear relationship within the range of 1 ag/mL to 100 ng/mL and low detection limit (0.39 ag/mL). Furthermore, the detection platform was also successfully applied to detection of SARS-CoV-2 coronavirus pathogens in soil solution, indicating the potential use in on-site application.


Asunto(s)
Enfermedades Transmisibles , Grafito , Humanos , Anticuerpos , SARS-CoV-2 , Fenómenos Magnéticos
4.
Sensors (Basel) ; 23(9)2023 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-37177552

RESUMEN

Herein, an ultra-sensitive and facile electrochemical biosensor for procalcitonin (PCT) detection was developed based on NiCoP/g-C3N4 nanocomposites. Firstly, NiCoP/g-C3N4 nanocomposites were synthesized using hydrothermal methods and then functionalized on the electrode surface by π-π stacking. Afterward, the monoclonal antibody that can specifically capture the PCT was successfully linked onto the surface of the nanocomposites with a 1-(3-Dimethylaminopropyl)-3-ethylcarbodiimide hydrochloride (EDC) and N-Hydroxysuccinimide (NHS) condensation reaction. Finally, the modified sensor was employed for the electrochemical analysis of PCT using differential Pulse Voltammetry(DPV). Notably, the larger surface area of g-C3N4 and the higher electron transfer capacity of NiCoP/g-C3N4 endow this sensor with a wider detection range (1 ag/mL to 10 ng/mL) and an ultra-low limit of detection (0.6 ag/mL, S/N = 3). In addition, this strategy was also successfully applied to the detection of PCT in the diluted human serum sample, demonstrating that the developed immunosensors have the potential for application in clinical testing.


Asunto(s)
Técnicas Biosensibles , Grafito , Nanopartículas del Metal , Nanocompuestos , Humanos , Polipéptido alfa Relacionado con Calcitonina , Técnicas Biosensibles/métodos , Inmunoensayo/métodos , Técnicas Electroquímicas/métodos , Límite de Detección , Oro
5.
Langmuir ; 36(2): 546-553, 2020 01 21.
Artículo en Inglés | MEDLINE | ID: mdl-31849232

RESUMEN

Conducting polymers tethered with molecular recognition elements are good candidates for biosensing applications such as detecting a target molecule with selectivity. We develop a new monomer, namely, 3,4-ethylenedioxythiophene bearing a pyridylboronic acid moiety (EDOT-PyBA), for label-free detection of sialic acid as a cancer biomarker. PyBA, which is known to show specific binding to sialic acid in acid conditions is used as a synthetic ligand instead of lectins. PyBA confirms the enhanced binding affinity for sialic acid at pH 5.0-6.0 compared with traditional phenylboronic acid. Poly(EDOT-PyBA) is electrodeposited on a planar glassy carbon electrode and the obtained film is successfully characterized by X-ray photoelectron spectroscopy, scanning electron microscopy, atomic force microscopy, water contact angle measurements, and electrochemical impedance spectroscopy. The specific interaction of PyBA with sialic acid at the solution/electrode interface is detected by differential pulse voltammetry in a dynamic range 0.1-3.0 mM with a detection limit of 0.1 mM for a detection time of 3 min. The sensitivity covers the total level of free sialic acid in human serum and the assay time is the shorter than that of other methods. The poly(EDOT-PyBA) electrode successfully detects spiked sialic acid in human serum samples. Owing to its processability, mass productivity, and robustness, polythiophene conjugated with "boronolectin" is a candidate material for developing point-of-care and wearable biosensors.

6.
Anal Chim Acta ; 1315: 342804, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38879211

RESUMEN

BACKGROUND: Rapid on-site detection of infectious diseases is considerably essential for preventing and controlling major epidemics and maintaining social and public safety. However, the complexity of the natural environment in which infectious disease pathogens exist severely disrupts the performance of on-site detection, and rapid detection can become meaningless because of the cumbersome sample pretreatment process. RESULT: Herein, a new detection platform based on a carbon sphere@Fe3O4 micromotor (CS@Fe3O4) in combination with a graphene field-effect transistor (GFET) was designed and used for the on-site detection of SARS-CoV-2 coronavirus pathogens. The CS@Fe3O4 micromotor, surface-modified with anti-SARS-CoV-2 coronavirus antibody, could move at a velocity of 79.4 µm/s in a solution containing hydrogen peroxide (H2O2) and exhibited capture rates of 67.9% and 36.2% for the SARS-CoV-2 pathogen in phosphate buffered saline (PBS) and soil solutions, respectively. After magnetic field separation, the captured micromotor was used for GFET detection, with detection limits of 4.6 and 15.6 ag/mL in PBS and soil solutions, respectively. SIGNIFICANCE AND NOVELTY: This detection platform can be employed to avoid complex sample pretreatment procedures and achieve rapid on-site detection of SARS-CoV-2 coronavirus pathogens in complex environments. This study introduces a novel approach for the on-site detection of infectious diseases.


Asunto(s)
COVID-19 , Carbono , Grafito , SARS-CoV-2 , Transistores Electrónicos , Grafito/química , SARS-CoV-2/aislamiento & purificación , SARS-CoV-2/inmunología , COVID-19/diagnóstico , COVID-19/virología , Carbono/química , Humanos , Límite de Detección , Técnicas Biosensibles/métodos , Peróxido de Hidrógeno/química , Óxido Ferrosoférrico/química
7.
Pharmaceutics ; 15(12)2023 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-38140091

RESUMEN

Cancer treatments, including traditional chemotherapy, have failed to cure human malignancies. The main reasons for the failure of these treatments are the inevitable drug resistance and serious side effects. In clinical treatment, only 5 percent of the 50 percent of cancer patients who are able to receive conventional chemotherapy survive. Because of these factors, being able to develop a drug and treatment that can target only cancer cells without affecting normal cells remains a big challenge. Since the special properties of cisplatin in the treatment of malignant tumors were accidentally discovered in the last century, metal anticancer drugs have become a research hotspot. Metal anticancer drugs have unique pharmaceutical properties, such as ruthenium metal drugs with their high selectivity, low toxicity, easy absorption by tumor tissue, excretion, and so on. In recent years, efficient and low-toxicity metal antitumor complexes have been synthesized. In this paper, the scientific literature on platinum (Pt), ruthenium (Ru), iridium (Ir), gold (Au), and other anticancer complexes was reviewed by referring to a large amount of relevant literature at home and abroad.

8.
RSC Adv ; 12(35): 22518-22525, 2022 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-36105974

RESUMEN

In this study, we established a label free and ultrasensitive electrochemical sensor based on graphitic nitride nanosheets (g-C3N4 NS) for procalcitonin (PCT) detection. Firstly, an easy-to-prepare and well-conducting g-C3N4 NS was synthesized. Next the g-C3N4 NS was immobilized on the electrode surface by π-π stacking, and further used to anchor the specific recognition peptide (PP). The surface morphology and structure after g-C3N4 NS and PP modification was characterized by X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM) and electrochemistry. The sensing property of this sensor was evaluated by differential pulse voltammetry (DPV) and showed a detection sensitivity with a dynamic range from 0.15 to 11.7 fg mL-1 with a low limit of detection (LOD) of 0.11 fg mL-1. Besides, the electrochemical biosensor was successfully used to detect PCT in human serum samples, and the results suggest its potential use in clinical application.

9.
ACS Appl Mater Interfaces ; 9(16): 14162-14170, 2017 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-28379685

RESUMEN

Conducting polymers are good candidates for biosensor applications when molecular recognition element is imparted. We developed trisaccharide-grafted conducting polymers for label-free detection of the human influenza A virus (H1N1) with high sensitivity and specificity. A 3,4-ethylenedioxythiophene (EDOT) derivative bearing an oxylamine moiety was electrochemically copolymerized with EDOT. The obtained film was characterized by cyclic voltammetry, X-ray photoelectron spectroscopy, scanning electron microscopy, stylus surface profilometer, and AC-impedance spectroscopy. The trisaccharides comprising Sia-α2,6'-Gal-Glu (2,6-sialyllactose) or Sia-α2,3'-Gal-Glu (2,3-sialyllactose) were covalently introduced to the side chain of the conducting polymers as a ligand for viral recognition. Immobilization of sialyllactose was confirmed by quartz crystal microbalance (QCM) and water contact angle measurements. Specific interaction of 2,6-sialyllactose with hemagglutinin in the envelope of the human influenza A virus (H1N1) was detected by QCM and potentiometry with enhanced sensitivity by 2 orders of magnitude when compared with that of commercially available kits. The developed conducting polymers possessing specific virus recognition are a good candidate material for wearable monitoring and point-of-care testing because of their processability and mass productivity in combination with printing technologies.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA