Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 118
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 100(5): 860-867, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36116028

RESUMEN

BACKGROUND: Transcatheter aortic valve-in-valve implantation (ViV-TAVI) has emerged in recent years as a safe alternative to redo surgery in high-risk patients. Although early results are encouraging, data beyond short-term outcomes are lacking. Herein, we aimed to assess the 2-year outcomes after ViV-TAVI. METHODS: Patients undergoing ViV-TAVI for degenerated surgical valves between 2013 and 2019 at the Cleveland Clinic were reviewed. The coprimary endpoints were all-cause mortality and congestive heart failure (CHF) hospitalizations. We used time-to-event analyses to assess the primary outcomes. Further, we measured the changes in transvalvular gradients and the incidence of structural valve deterioration (SVD). RESULTS: One hundred and eighty-eight patients were studied (mean age = 76 years; 65% males). At 2 years of follow-up, all-cause mortality and CHF hospitalizations occurred in 15 (8%) and 28 (14.9%) patients, respectively. On multivariable analysis, the postprocedural length of stay was a significant predictor for both all-cause mortality (hazard ratio [HR] = 1.1; 95% confidence interval [CI]: 1.01, 1.19) and CHF hospitalization (HR = 1.16; 95% CI: 1.07, 1.27). However, the internal diameter of the surgical valve was not associated with significant differences in both primary endpoints. For hemodynamic outcomes, nine patients (4.8%) developed SVD. The mean and peak transvalvular pressure gradients remained stable over the follow-up period. CONCLUSION: ViV-TAVI for degenerated surgical valves was associated with favorable 2-year clinical and hemodynamic outcomes. Further studies are needed to better understand the role of ViV-TAVI as a treatment option in the life management of aortic valve disease.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Anciano , Femenino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Bioprótesis/efectos adversos , Falla de Prótesis , Reoperación/métodos , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Implantación de Prótesis de Válvulas Cardíacas/métodos
2.
Dig Dis Sci ; 67(11): 5315-5326, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35150344

RESUMEN

BACKGROUND: Recently, the Cirrhotic Cardiomyopathy Consortium (Consortium) proposed criteria to replace the World Congress of Gastroenterology (WGO) criteria for cirrhotic cardiomyopathy (CCM) using contemporary echocardiography parameters. We assessed the impact of substituting WGO by Consortium criteria on the frequency of diagnosis and clinical outcomes in patients with cirrhosis awaiting liver transplantation (LT). METHODS: Consecutive adults with cirrhosis approved for LT with echocardiography evaluation from January 2014 to December 2016 were screened. Patients with structural heart diseases were excluded. Two primary outcomes were: (1) frequency of CCM; (2) association of CCM with pre-transplant mortality. The secondary outcomes were pre-LT complications of acute kidney injury (AKI) and/or hepatic encephalopathy (HE), and post-LT mortality. RESULTS: Of 386 patients screened, 278 were included. 238 (85.6%) and 208 (74.8%) patients met Consortium and WGO criteria, respectively; 180 (64.7%) patients fulfilled both the criteria, while 12 (4.3%) patients had no evidence of CCM by either criterion. Pre-LT mortality rates in Consortium-CCM group were similar to the other groups (19.3% vs 20.2% vs 25.0%). The patients with advanced diastolic dysfunction (DD) per Consortium-CCM criteria had higher mortality than the other groups. The rates of pre-LT AKI/HE rates and post-LT mortality were similar in Consortium-CCM and WGO-CCM groups. CONCLUSION: The Consortium criteria do not impact the prevalence of CCM compared to WGO criteria and have similar predictive accuracy. Presence of advanced DD per the Consortium criteria increases the risk of pre-LT mortality and complications of AKI/HE. The patients with advanced DD could benefit from further monitoring and treatment.


Asunto(s)
Lesión Renal Aguda , Cardiomiopatías , Trasplante de Hígado , Adulto , Humanos , Trasplante de Hígado/efectos adversos , Estudios Retrospectivos , Cirrosis Hepática/epidemiología , Cardiomiopatías/etiología , Cardiomiopatías/diagnóstico , Lesión Renal Aguda/complicaciones
3.
Curr Cardiol Rep ; 24(12): 1917-1932, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36334213

RESUMEN

PURPOSE OF REVIEW: Transcatheter mitral valve replacement (TMVR) is an evolving and rapidly expanding field within structural interventions, offering renewed treatment options for patients with high-risk mitral valve disease. We aim to highlight and illustrate the importance of cardiac CT in the planning of TMVR. RECENT FINDINGS: As TMVR has evolved, so has the specific nuances of cardiac CT planning, we now understand the importance of accurate annular sizing and valve simulation to predict complications such as neo-LVOT obstruction and paravalvular leak (PVL). More so than any other modality, cardiac CT remains instrumental in accurately planning TVMR from feasibility, device sizing, access, and fluoroscopic angles. Cardiac CT remains the key modality in TMVR evaluation, often the first step in determining patient eligibility through comprehensive procedural planning as well as informing potential outcomes and prognosis. In this review, we discuss the critical role of cardiac computed tomography (CT) and the specific considerations involved in TMVR.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Obstrucción del Flujo Ventricular Externo , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas/efectos adversos , Obstrucción del Flujo Ventricular Externo/cirugía , Tomografía Computarizada por Rayos X , Cateterismo Cardíaco/métodos , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/complicaciones
4.
J Nucl Cardiol ; 28(2): 536-542, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30877551

RESUMEN

BACKGROUND: Assessing for coronary artery disease (CAD) in patients with left bundle branch block (LBBB) is difficult with noninvasive cardiac imaging. Few studies report the prevalence of LBBB associated septal-apical perfusion defects using regadenoson stress on Positron Electron Tomography (PET) imaging. METHODS AND RESULTS: We identified 101 consecutive patients with baseline LBBB, and without known CAD, who underwent rest-stress regadenoson PET. Investigators have the ability to prospectively identify studies, whose quality is limited by LBBB artifact. With the infusion of regadenoson, resting to peak stress heart rate rose from a median of 78 to 93 BPM. Despite this, LBBB perfusion artifacts were not identified in any studies. 10 individuals had both regadenoson SPECT and PET within 1 year. 3 of the 10 SPECT studies had LBBB artifacts, all of which were not seen on subsequent PET. 21 patients with PET had subsequent coronary angiography. Of these, 9 PETs were without significant inducible ischemia, and angiogram was without flow-limiting disease. 3 PETs identified inducible ischemia, but did not have flow-limiting disease on angiogram. 9 PETs identified inducible ischemia and had flow-limiting disease on angiogram. CONCLUSIONS: In patients with LBBB undergoing regadenoson PET stress imaging, artifactual septal perfusion defects are rare.


Asunto(s)
Bloqueo de Rama/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Tabiques Cardíacos/diagnóstico por imagen , Imagen de Perfusión Miocárdica/métodos , Tomografía de Emisión de Positrones/métodos , Purinas/farmacología , Pirazoles/farmacología , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada de Emisión de Fotón Único
5.
Curr Cardiol Rep ; 23(9): 114, 2021 07 16.
Artículo en Inglés | MEDLINE | ID: mdl-34269899

RESUMEN

PURPOSE OF REVIEW: The field of transcatheter tricuspid valve interventions (TTVI) is rapidly evolving to meet a well-defined but unmet clinical need. Severe tricuspid regurgitation is common and is associated with significant morbidity and mortality. Surgical options are limited and of high risk. The success of TTVI depends on careful procedural planning, and cardiac computed tomography (CCT) plays an emerging key role. RECENT FINDINGS: TTVI technologies have various targets, including the leaflets, annulus, and venae cavae, along with valve replacement. Based on the planned procedure, CCT allows for device sizing, careful assessment of the access route, and comprehensive analysis of relevant adjacent anatomic structures to enhance procedural safety. It can also evaluate right-sided heart function, and its data can be for fusion imaging and 3D printing. Procedural planning is key to TTVI's success and is highly dependent on high-quality CCT data. This review details the comprehensive roles of CCT, specifics of the dedicated TTVI protocol, and its limitations.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Cateterismo Cardíaco , Humanos , Tomografía , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía
6.
Catheter Cardiovasc Interv ; 96(2): 330-335, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32233062

RESUMEN

Three-dimensional (3D) printing has had an evolving role in cardiology, although has been largely reserved for planning of structural heart disease interventions. We present a case whereby multimodality imaging, including 3D printing, played a pivotal role in planning a technically feasible approach for complex percutaneous coronary intervention of a chronically occluded anomalous right coronary artery, with creation of a customized guide catheter.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Oclusión Coronaria/terapia , Anomalías de los Vasos Coronarios , Impresión Tridimensional , Anciano , Enfermedad Crónica , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Oclusión Coronaria/diagnóstico por imagen , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Diseño de Equipo , Femenino , Humanos , Modelos Anatómicos , Modelos Cardiovasculares , Tomografía Computarizada Multidetector , Stents , Resultado del Tratamiento
7.
Echocardiography ; 36(1): 94-101, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30471079

RESUMEN

AIM: The aim of this study was to investigate whether conventional echocardiographic assessment of right ventricular (RV) systolic function can be improved by the addition of RV strain imaging. Additionally, we also aimed to investigate whether dedicated reading sessions and education can improve echocardiographic interpretation of RV systolic function. METHODS: Readers of varying expertise (staff echocardiologists, advanced cardiovascular imaging fellows, sonographers) assessed RV systolic function. In session 1, 20 readers graded RV function of 19 cases, using conventional measures. After dedicated education, in session 2, the same cases were reassessed, with the addition of RV strains. In session 3, 18 readers graded RV function of 20 additional cases, incorporating RV strains. Computer simulations were performed to obtain 230 random teams. RV ejection fraction (RVEF) by cardiac magnetic resonance (CMR) was the reference standard. RESULTS: Correlation between RV GLS and CMR-derived RVEF was moderate: Spearman's rho: 0.70, n = 19, P < 0.001 (first two sessions); 0.55, n = 20, P < 0.05 (third session). Individual readers' assessment moderately correlated with RVEF (Spearman's rho first session: 0.67 ± 0.2; second session: 0.61 ± 0.2; and third session: 0.68 ± 0.09). Team estimates of RV systolic function showed consistently better correlation with RVEF, which were improved further by averaging across all readers. RV strain parameters influenced echocardiographic interpretation, with a net reclassification index of 8.0 ± 3.6% (P = 0.014). CONCLUSIONS: The RV strain parameters showed moderate correlations with CMR-derived RVEF and appropriately influenced echocardiographic interpretation of RV systolic function. "Wisdom of the crowd" applied by averaging echocardiographic assessments of RV systolic function across teams of echocardiography readers, further improved echocardiographic assessment of RV systolic function.


Asunto(s)
Ecocardiografía/métodos , Imagen por Resonancia Magnética/métodos , Disfunción Ventricular Derecha/diagnóstico por imagen , Función Ventricular Derecha/fisiología , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
8.
J Nucl Cardiol ; 24(3): 1094-1097, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-27016106

RESUMEN

BACKGROUND: Tc99m-pyrophosphate (Tc99m-PYP) scintigraphy has emerged as a diagnostic modality for transthyretin (TTR) cardiac amyloidosis (CA). We sought to examine the variability in test utilization across multiple centers in the US. METHODS: An electronic, web-based survey addressing specifics on Tc-99m PYP imaging was emailed to ASNC members, totaling 2785 recipients. Only one response per institution was allowed. RESULTS: Responses were collected from 101 centers between July 2 and July 27, 2015. Among the respondents, 24% performed Tc-99m PYP specifically for CA diagnosis. The most commonly used dose was 20 mCi (37%) and most centers (35%) imaged 1 hour after injection. Scans were most often interpreted by cardiologists (60%). Quantification of uptake was performed in 57% of institutions with almost half (43%) utilizing the heart-to-contralateral lung (H/CL) ratio. CONCLUSIONS: This national survey shows relatively low penetrance and high variability in Tc99m-PYP scintigraphy for CA diagnosis highlighting the need for standardization.


Asunto(s)
Neuropatías Amiloides Familiares/diagnóstico por imagen , Neuropatías Amiloides Familiares/epidemiología , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/epidemiología , Pautas de la Práctica en Medicina/estadística & datos numéricos , Pirofosfato de Tecnecio Tc 99m , Revisión de Utilización de Recursos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Radiofármacos , Estados Unidos/epidemiología
9.
Curr Cardiol Rep ; 19(8): 73, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28688022

RESUMEN

PURPOSE OF REVIEW: This review aims to provide a comprehensive assessment of mitral valve disease, both mitral stenosis and mitral regurgitation, starting with an overview of the valve anatomy. RECENT FINDINGS: The advent of three-dimensional imaging has allowed a better representation of the valve anatomy. Rheumatic disease is still the number one cause of mitral stenosis worldwide and percutaneous balloon mitral valvuloplasty remains the therapy of choice when indicated and in anatomically eligible patients. Mitral regurgitation (MR) is classified as primary (i.e., lesion in the mitral apparatus) or secondary (caused by left ventricular geometrical alterations). While surgery, preferably repair, is still the recommended therapy for severe primary MR, percutaneous approaches to repair and/or replace the mitral valve are being extensively investigated. Mitral valve disease is common. A careful understanding of mitral valve anatomy and the disease processes that affect the valve are crucial for providing optimal patient care.


Asunto(s)
Insuficiencia de la Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Procedimientos Quirúrgicos Cardíacos , Humanos , Imagenología Tridimensional , Válvula Mitral/anatomía & histología , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/patología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/etiología , Cardiopatía Reumática/complicaciones
10.
Curr Cardiol Rep ; 19(7): 60, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28528454

RESUMEN

PURPOSE OF REVIEW: This review article aims to provide a contemporary insight into the pathophysiological mechanisms of and therapeutic targets for pericarditis, drawing distinction between autoinflammatory and autoimmune pericarditis. RECENT FINDINGS: Recent research has focused on the distinction between autoinflammatory and autoimmune pericarditis. In autoinflammatory pericarditis, viruses can activate the sensor molecule of the inflammasome, which results in downstream release of cytokines, such as interleukin-1, that recruit neutrophils and macrophages to the site of injury. Conversely, in autoimmune pericarditis, a type I interferon signature predominates, and pericardial manifestations coincide with the severity of the underlying systemic autoimmune disease. In addition, autoimmune pericarditis can also develop after cardiac injury syndromes. With either type of pericarditis, imaging can help stage the inflammatory state. Prominent pericardial delayed hyperenhancement on magnetic resonance imaging suggests ongoing inflammation whereas calcium on computed tomography suggests a completed inflammatory cascade. In patients with ongoing pericarditis, treatments that converge on the inflammasome, such as colchicine and anakinra, have proved effective in recurrent autoinflammatory pericarditis, though further clinical trials with anakinra are warranted. An improved understanding of the pathophysiological mechanisms of pericarditis helps unravel effective therapeutic targets for this condition.


Asunto(s)
Enfermedades Autoinmunes/etiología , Enfermedades Autoinmunes/terapia , Pericarditis/etiología , Pericarditis/terapia , Colchicina/uso terapéutico , Humanos , Interferón Tipo I/metabolismo , Proteína Antagonista del Receptor de Interleucina 1/uso terapéutico , Pericarditis/diagnóstico por imagen
11.
Am Heart J ; 167(1): 77-85, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24332145

RESUMEN

BACKGROUND: Risk assessment may be important in patients being considered for repeat revascularization after prior coronary intervention or surgery. We sought the prognostic value of radionuclide stress myocardial perfusion imaging or echocardiography among patients with previous revascularization. METHODS: Studies on the outcomes of stress imaging tests after revascularization were selected from an electronic search if they reported the odds or hazard ratio (HR) of an abnormal stress test in the prediction of mortality (cardiac or total), hard cardiac events (cardiac death and myocardial infarction [MI]), total hard events (total mortality and MI]), or overall events (cardiac death, MI, and repeat revascularization). RESULTS: In 29 studies (12,874 patients, 63 ± 3 years, 80% men), an abnormal test result was associated with hard cardiac events (HR 1.2, 95% CI 1.1-1.3), cardiac mortality (HR 5.8, 95% CI 0.8-10.8), total mortality (HR 2.2, 95% CI 1.3-3.1), total hard events(HR 2.4, 95% CI 1.4-3.3), and overall events (HR 1.2, 95% CI 1.1-1.3). The nature of the end point was not associated with differences in the prediction of events, but the type of revascularization showed a significant association with outcome, with percutaneous intervention portending a worse outcome. Age and the timing of the stress imaging postrevascularization were inversely associated with survival. Gender, length of follow-up after testing, symptom status, past infarction, and risk factor status did not explain interstudy heterogeneity. CONCLUSIONS: In patients with previous revascularization, abnormal results at stress echocardiography or radionuclide myocardial perfusion imaging are predictive of subsequent events, with age, type of revascularization, and the timing of the stress imaging after revascularization being important sources of heterogeneity between studies.


Asunto(s)
Ecocardiografía de Estrés , Infarto del Miocardio/terapia , Imagen de Perfusión Miocárdica/métodos , Revascularización Miocárdica , Puente de Arteria Coronaria , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/mortalidad , Isquemia Miocárdica/epidemiología , Pronóstico , Retratamiento , Medición de Riesgo
13.
Cardiol Clin ; 42(3): 351-360, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38910020

RESUMEN

Echocardiography, in all its forms (transthoracic echocardiography [TTE], transesophageal echocardiography [TEE], and intracardiac echocardiography [ICE]), is pivotal for the evaluation, guidance, and follow-up of transcatheter tricuspid edge-to-edge repair (TV-TEER) therapies. Although two-dimensional (2D) echocardiography remains essential, three-dimensional (3D) echo with multiplanar reconstruction (MPR) has revolutionized the field of structural imaging. In addition, the advent of 3D ICE has added an important modality to the imaging toolbox, particularly helpful when intraprocedural TEE images are challenging. In this review, we provide a detailed, step-by-step approach for advanced echocardiographic guidance of TV-TEER using 3D MPR.


Asunto(s)
Cateterismo Cardíaco , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Cateterismo Cardíaco/métodos , Ecocardiografía/métodos , Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Ultrasonografía Intervencional/métodos
14.
JACC Cardiovasc Imaging ; 17(4): 428-440, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38569793

RESUMEN

Structural heart disease interventions rely heavily on preprocedural planning and simulation to improve procedural outcomes and predict and prevent potential procedural complications. Modeling technologies, namely 3-dimensional (3D) printing and computational modeling, are nowadays increasingly used to predict the interaction between cardiac anatomy and implantable devices. Such models play a role in patient education, operator training, procedural simulation, and appropriate device selection. However, current modeling is often limited by the replication of a single static configuration within a dynamic cardiac cycle. Recognizing that health systems may face technical and economic limitations to the creation of "in-house" 3D-printed models, structural heart teams are pivoting to the use of computational software for modeling purposes.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Cardiopatías , Humanos , Valor Predictivo de las Pruebas , Procedimientos Quirúrgicos Cardíacos/métodos , Simulación por Computador , Cardiopatías/diagnóstico por imagen , Cardiopatías/terapia , Programas Informáticos , Impresión Tridimensional
15.
JACC Cardiovasc Imaging ; 17(1): 1-12, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37498256

RESUMEN

BACKGROUND: There are limited data on the sex differences in the hemodynamic progression and outcomes of early-stage aortic stenosis (AS). OBJECTIVES: The authors sought to determine sex differences in hemodynamic progression and outcomes of mild to moderate native AS. METHODS: This was a retrospective observational cohort study including patients with mild to moderate native tricuspid AS from the Cleveland Clinic echocardiographic database between 2008 and 2016 and followed until 2018. All-cause mortality, aortic valve replacement (AVR), and disease progression assessed by annualized changes in echocardiographic parameters were analyzed based on sex. RESULTS: The authors included 2,549 patients (mean age, 74 ± 7 years and 42.5% women) followed over a median duration of 5.7 years. There was no difference in all-cause mortality between sexes irrespective of age, baseline disease severity, progression to severe AS, and receipt of AVR. Relative to men, women had similar all-cause mortality but lower risk of AVR (adjusted HR: 0.81 [95% CI: 0.67-0.91]; P = 0.009) at 10 years. On 1:1 propensity-matched analysis, men had a significantly faster disease progression represented by greater increases in the median of annualized change in mean gradient (2.10 vs 1.15 mm Hg/y, respectively, P < 0.001), maximum transvalvular velocity (0.42 vs 0.28 m/s/y), left ventricular end-diastolic diameters (0.15 vs 0.048 mm/m2.7/y) (P = 0.014). Women have significantly higher left ventricular ejection fraction, filling pressures, and left ventricular septum thickness over time on follow-up echocardiograms compared with men. CONCLUSIONS: Women with mild to moderate AS had slower hemodynamic progression of AS, were more likely to have preserved left ventricular ejection fraction and concentric left ventricular hypertrophy in addition to lower incidence of AVR compared with men despite similar mortality. These findings provide further evidence that there are distinct sex-specific longitudinal echocardiographic and clinical profiles in patients with AS.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Femenino , Masculino , Anciano , Anciano de 80 o más Años , Volumen Sistólico , Función Ventricular Izquierda , Estudios de Cohortes , Estudios de Seguimiento , Caracteres Sexuales , Valor Predictivo de las Pruebas , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Progresión de la Enfermedad , Índice de Severidad de la Enfermedad , Estudios Retrospectivos
16.
Artículo en Inglés | MEDLINE | ID: mdl-38641438

RESUMEN

BACKGROUND: Candidates for transcatheter aortic valve replacement (TAVR) occasionally have a "borderline-size" aortic annulus between 2 transcatheter heart valve sizes, based on the manufacturer's sizing chart. Data on TAVR outcomes in such patients are limited. METHODS: We retrospectively reviewed 1816 patients who underwent transfemoral-TAVR with balloon-expandable valve (BEV) at our institution between 2016 and 2020. We divided patients into borderline and non-borderline groups based on computed tomography-derived annular measurements and compared outcomes. Furthermore, we analyzed procedural characteristics and compared outcomes between the smaller- and larger-valve strategies in patients with borderline-size annulus. RESULTS: During a median follow-up of 23.3 months, there was no significant difference between the borderline (n = 310, 17.0 %) and non-borderline (n = 1506) groups in mortality (17.3 % vs. 19.5 %; hazard ratio [HR] = 0.86 [95% CI = 0.62-1.20], p = 0.39), major adverse cardiac/cerebrovascular events (MACCE: death/myocardial infarction/stroke, 21.2 % vs. 21.5 %; HR = 0.97 [0.71-1.32], p = 0.85), paravalvular leak (PVL: mild 21.8 % vs. 20.6 %, p = 0.81; moderate 0 % vs. 1.2 %; p = 0.37), or mean gradient (12.9 ± 5.8 vs. 12.6 ± 5.2 mmHg, p = 0.69) at 1 year. There was no significant difference between the larger-(n = 113) and smaller-valve(n = 197) subgroups in mortality (23.7 % vs. 15.2 %; HR = 1.57 [0.89-2.77], p = 0.12), MACCE (28.1 % vs. 18.4 %; HR = 1.52 [0.91-2.54], p = 0.11), mild PVL (13.3 % vs. 25.9 %; p = 0.12), or mean gradient (12.3 ± 4.5 vs. 13.6 ± 5.3 mmHg, p = 0.16); however, the rate of permanent pacemaker implantation (PPI) was higher in the larger-valve subgroup (15.9 % vs. 2.6 %, p < 0.001). CONCLUSION: Borderline-size annulus is not associated with higher risk of adverse outcomes after BEV-TAVR. However, the larger-valve strategy for borderline-size annulus is associated with higher PPI risk, suggesting a greater risk of injury to the conduction system.

17.
Open Heart ; 11(1)2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38769066

RESUMEN

OBJECTIVE: Patients with moderate aortic stenosis (AS) exhibit high morbidity and mortality. Limited evidence exists on the role of aortic valve replacement (AVR) in this patient population. To investigate the benefit of AVR in moderate AS on survival and left ventricular function. METHODS: In a retrospective cohort study, patients with moderate AS between 2008 and 2016 were selected from the Cleveland Clinic echocardiography database and followed until 2018. Patients were classified as receiving AVR or managed medically (clinical surveillance). All-cause and cardiovascular mortality were assessed by survival analyses. Temporal haemodynamic and structural changes were assessed with longitudinal analyses using linear mixed effects models. RESULTS: We included 1421 patients (mean age, 75.3±5.4 years and 39.9% women) followed over a median duration of 6 years. Patients in the AVR group had lower risk of all-cause (adjusted HR (aHR)=0.51, 95% CI: 0.34 to 0.77; p=0.001) and cardiovascular mortality (aHR=0.50, 95% CI: 0.31 to 0.80; p=0.004) compared with those in the clinical surveillance group irrespective of sex, receipt of other open-heart surgeries and underlying malignancy. These findings were seen only in those with preserved left ventricular ejection fraction (LVEF) ≥50%. Further, patients in the AVR group had a significant trend towards an increase in LVEF and a decrease in right ventricular systolic pressure compared with those in the clinical surveillance group. CONCLUSIONS: In patients with moderate AS, AVR was associated with favourable clinical outcomes and left ventricular remodelling.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Función Ventricular Izquierda , Humanos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/diagnóstico , Femenino , Masculino , Estudios Retrospectivos , Anciano , Implantación de Prótesis de Válvulas Cardíacas/métodos , Función Ventricular Izquierda/fisiología , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Resultado del Tratamiento , Factores de Tiempo , Índice de Severidad de la Enfermedad , Estudios de Seguimiento , Factores de Riesgo , Ecocardiografía/métodos , Anciano de 80 o más Años , Tasa de Supervivencia/tendencias , Medición de Riesgo/métodos , Volumen Sistólico/fisiología
18.
J Am Heart Assoc ; 13(3): e032760, 2024 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-38293932

RESUMEN

BACKGROUND: Data regarding permanent pacemaker (PPM) implantation following tricuspid valve surgery (TVS) are limited. We sought to evaluate its incidence, risk factors, and outcomes. METHODS AND RESULTS: Medicare beneficiaries who underwent TVS from 2013 to 2020 were identified. Patients who underwent TVS for endocarditis were excluded. The primary exposure of interest was new PPM after TVS. Outcomes included all-cause mortality and readmission with endocarditis or heart failure on follow-up. Among the 13 294 patients who underwent TVS, 2518 (18.9%) required PPM placement. Risk factors included female sex (relative risk [RR], 1.26 [95% CI, 1.17-1.36], P<0.0001), prior sternotomy (RR, 1.12 [95% CI, 1.02-1.23], P=0.02), preoperative second-degree heart block (RR, 2.20 [95% CI, 1.81-2.69], P<0.0001), right bundle-branch block (RR, 1.21 [95% CI, 1.03-1.41], P=0.019), bifascicular block (RR, 1.43 [95% CI, 1.06-1.93], P=0.02), and prior malignancy (RR, 1.23 [95% CI, 1.01-1.49], P=0.04). Tricuspid valve (TV) replacement was associated with a significantly higher risk of PPM implantation when compared with TV repair (RR, 3.20 [95% CI, 2.16-4.75], P<0.0001). After a median follow-up of 3.1 years, mortality was not different in patients who received PPM compared with patients who did not (hazard ratio [HR], 1.02 [95% CI, 0.93-1.12], P=0.7). PPM placement was not associated with a higher risk of endocarditis but was associated with a higher risk of heart failure readmission (HR, 1.28 [95% CI, 1.14-1.43], P<0.001). CONCLUSIONS: PPM implantation frequently occurs after TVS, notably in female patients and patients undergoing TV replacement. Although mortality is not increased, it is associated with higher rates of heart failure rehospitalization.


Asunto(s)
Estenosis de la Válvula Aórtica , Endocarditis , Insuficiencia Cardíaca , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano , Estados Unidos/epidemiología , Estenosis de la Válvula Aórtica/cirugía , Estimulación Cardíaca Artificial/efectos adversos , Incidencia , Válvula Tricúspide/cirugía , Resultado del Tratamiento , Medicare , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Bloqueo de Rama/terapia , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/complicaciones , Endocarditis/cirugía , Válvula Aórtica/cirugía , Estudios Retrospectivos
19.
JTCVS Open ; 18: 12-30, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38690415

RESUMEN

Objective: Anterior mitral anular calcification, particularly in radiation heart disease, and previous valve replacement with destroyed intervalvular fibrosa are challenging for prosthesis sizing and placement. The Commando procedure with intervalvular fibrosa reconstruction permits double-valve replacement in these challenging conditions. We referenced outcomes after Commando procedures to standard double-valve replacements. Methods: From January 2011 to January 2022, 129 Commando procedures and 1191 aortic and mitral double-valve replacements were performed at the Cleveland Clinic, excluding endocarditis. Reasons for the Commando were severe calcification after radiation (n = 67), without radiation (n = 43), and others (n = 19). Commando procedures were referenced to a subset of double-valve replacements using balancing-score methods (109 pairs). Results: Between balanced groups, Commando versus double-valve replacement had higher total calcium scores (median 6140 vs 2680 HU, P = .03). Hospital outcomes were similar, including operative mortality (12/11% vs 8/7.3%, P = .35) and reoperation for bleeding (9/8.3% vs 5/4.6%, P = .28). Survival and freedom from reoperation at 5 years were 54% versus 67% (P = .33) and 87% versus 100% (P = .04), respectively. Higher calcium score was associated with lower survival after double-valve replacement but not after the Commando. The Commando procedure had lower aortic valve mean gradients at 4 years (9.4 vs 11 mm Hg, P = .04). After Commando procedures for calcification, 5-year survival was 60% and 59% with and without radiation, respectively (P = .47). Conclusions: The Commando procedure with reconstruction of the intervalvular fibrosa destroyed by mitral anular calcification, radiation, or previous surgery demonstrates acceptable outcomes similar to standard double-valve replacement. More experience and long-term outcomes are required to refine patient selection for and application of the Commando approach.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA