Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Vasc Interv Radiol ; 31(11): 1874-1885, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-33129433

RESUMEN

PURPOSE: To assess the feasibility of inducing vascular occlusion by application of radiofrequency (RF) energy via conductive endovascular wires or baskets. MATERIALS AND METHODS: A retrievable nitinol basket and stainless steel guidewire with a platinum tip were evaluated as conductors for endovascular application of RF energy. Tissue-mimicking thermochromic gel phantoms that change color with heating were cast with 2-, 5-, and 7-mm-diameter lumens and filled with 37 oC saline. After ablation, the phantoms were sectioned, and the thermal footprints were evaluated. Six castrated male domestic swine underwent endovascular ablation using the basket in iliac arteries and guidewires in renal arteries. Post-procedural angiography was performed, and postmortem arterial segments were resected for histopathologic analysis. RESULTS: In the phantom, the depth of thermal change in the 5- and 7-mm lumens averaged 6.3 and 6.0 mm along the basket, respectively, and in the 2- and 5-mm lumens, the depth of thermal change averaged 1.9 and 0.5 mm along the wire, respectively. In the swine, RF energy delivery led to angiographic occlusion at 12 of 13 sites. Thermal injury and occlusion were similar at the proximal, middle, and distal basket treatment zone, whereas injury and occlusion decreased from the proximal to the distal end of the 5-cm wire treatment zone. CONCLUSIONS: Endovascular delivery of RF energy via a conductive basket in medium-sized arteries or a guidewire in small arteries led to acute angiographic and histologic occlusion. The potential to induce stasis might be useful in settings where rapid occlusion is desirable.


Asunto(s)
Procedimientos Endovasculares/instrumentación , Arteria Ilíaca/cirugía , Ablación por Radiofrecuencia/instrumentación , Arteria Renal/cirugía , Aleaciones , Animales , Conductividad Eléctrica , Diseño de Equipo , Estudios de Factibilidad , Calor , Arteria Ilíaca/patología , Masculino , Ensayo de Materiales , Modelos Animales , Orquiectomía , Platino (Metal) , Arteria Renal/patología , Acero Inoxidable , Sus scrofa
2.
Mol Med ; 18: 606-17, 2012 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-22398685

RESUMEN

Chronic stress is associated with negative health outcomes and is linked with neuroendocrine changes, deleterious effects on innate and adaptive immunity, and central nervous system neuropathology. Although stress management is commonly advocated clinically, there is insufficient mechanistic understanding of how decreasing stress affects disease pathogenesis. Therefore, we have developed a "calm mouse model" with caging enhancements designed to reduce murine stress. Male BALB/c mice were divided into four groups: control (Cntl), standard caging; calm (Calm), large caging to reduce animal density, a cardboard nest box for shelter, paper nesting material to promote innate nesting behavior, and a polycarbonate tube to mimic tunneling; control exercise (Cntl Ex), standard caging with a running wheel, known to reduce stress; and calm exercise (Calm Ex), calm caging with a running wheel. Calm, Cntl Ex and Calm Ex animals exhibited significantly less corticosterone production than Cntl animals. We also observed changes in spleen mass, and in vitro splenocyte studies demonstrated that Calm Ex animals had innate and adaptive immune responses that were more sensitive to acute handling stress than those in Cntl. Calm animals gained greater body mass than Cntl, although they had similar food intake, and we also observed changes in body composition, using magnetic resonance imaging. Together, our results suggest that the Calm mouse model represents a promising approach to studying the biological effects of stress reduction in the context of health and in conjunction with existing disease models.


Asunto(s)
Ratones , Modelos Animales , Estrés Psicológico , Animales , Conducta Animal , Composición Corporal , Peso Corporal , Corticosterona/biosíntesis , Modelos Animales de Enfermedad , Ingestión de Energía , Ambiente , Masculino , Ratones Endogámicos BALB C , Hormonas Peptídicas/sangre , Condicionamiento Físico Animal
3.
J Virol ; 85(14): 6977-85, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21525339

RESUMEN

Eight percent of the human genome is composed of human endogenous retroviruses (HERVs), which are thought to be inactive remnants of ancient infections. Previously, we showed that individuals with early HIV-1 infection have stronger anti-HERV T cell responses than uninfected controls. In this study, we investigated whether these responses persist in chronic HIV-1 infection and whether they have a role in the control of HIV-1. Peripheral blood mononuclear cells (PBMCs) from 88 subjects diagnosed with HIV-1 infection for at least 1 year (median duration of diagnosis, 13 years) were tested for responses against HERV peptides in gamma interferon (IFN-γ) enzyme immunospot (ELISPOT) assays. Individuals who control HIV-1 viremia without highly active antiretroviral therapy (HAART) had stronger and broader HERV-specific T cell responses than HAART-suppressed patients, virologic noncontrollers, immunologic progressors, and uninfected controls (P < 0.05 for each pairwise comparison). In addition, the magnitude of the anti-HERV T cell response was inversely correlated with HIV-1 viral load (r(2) = 0.197, P = 0.0002) and associated with higher CD4(+) T cell counts (r(2) = 0.072, P = 0.027) in untreated patients. Flow cytometric analyses of an HLA-B51-restricted CD8(+) HERV response in one HIV-1-infected individual revealed a less activated and more differentiated phenotype than that stimulated by a homologous HIV-1 peptide. HLA-B51 tetramer dual staining within this individual confirmed two different T cell populations corresponding to these HERV and HIV-1 epitopes, ruling out cross-reactivity. These findings suggest a possible role for anti-HERV immunity in the control of chronic HIV-1 infection and provide support for a larger effort to design an HIV-1 vaccine that targets conserved antigens such as HERV.


Asunto(s)
Linfocitos T CD4-Positivos/inmunología , Retrovirus Endógenos/inmunología , Infecciones por VIH/inmunología , VIH-1/fisiología , Terapia Antirretroviral Altamente Activa , Enfermedad Crónica , Ensayo de Inmunoadsorción Enzimática , Femenino , Citometría de Flujo , Productos del Gen env/inmunología , Productos del Gen gag/inmunología , Infecciones por VIH/tratamiento farmacológico , Infecciones por VIH/virología , Humanos , Inmunofenotipificación , Masculino
4.
Cell Rep ; 41(6): 111628, 2022 11 08.
Artículo en Inglés | MEDLINE | ID: mdl-36351401

RESUMEN

Pathogens evade host humoral responses by accumulating mutations in surface antigens. While variable, there are conserved regions that cannot mutate without compromising fitness. Antibodies targeting these conserved epitopes are often broadly protective but remain minor components of the repertoire. Rational immunogen design leverages a structural understanding of viral antigens to modulate humoral responses to favor these responses. Here, we report an epitope-enriched immunogen presenting a higher copy number of the influenza hemagglutinin (HA) receptor-binding site (RBS) epitope relative to other B cell epitopes. Immunization in a partially humanized murine model imprinted with an H1 influenza shows H1-specific serum and >99% H1-specific B cells being RBS-directed. Single B cell analyses show a genetically restricted response that structural analysis defines as RBS-directed antibodies engaging the RBS with germline-encoded contacts. These data show how epitope enrichment expands B cell responses toward conserved epitopes and advances immunogen design approaches for next-generation viral vaccines.


Asunto(s)
Vacunas contra la Influenza , Gripe Humana , Humanos , Ratones , Animales , Glicoproteínas Hemaglutininas del Virus de la Influenza/química , Anticuerpos Antivirales , Epítopos de Linfocito B
5.
Cardiovasc Intervent Radiol ; 44(5): 774-781, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33409547

RESUMEN

PURPOSE: To compare needle placement performance using an augmented reality (AR) navigation platform implemented on smartphone or smartglasses devices to that of CBCT-guided fluoroscopy in a phantom. MATERIALS AND METHODS: An AR application was developed to display a planned percutaneous needle trajectory on the smartphone (iPhone7) and smartglasses (HoloLens1) devices in real time. Two AR-guided needle placement systems and CBCT-guided fluoroscopy with navigation software (XperGuide, Philips) were compared using an anthropomorphic phantom (CIRS, Norfolk, VA). Six interventional radiologists each performed 18 independent needle placements using smartphone (n = 6), smartglasses (n = 6), and XperGuide (n = 6) guidance. Placement error was defined as the distance from the needle tip to the target center. Placement time was recorded. For XperGuide, dose-area product (DAP, mGy*cm2) and fluoroscopy time (sec) were recorded. Statistical comparisons were made using a two-way repeated measures ANOVA. RESULTS: The placement error using the smartphone, smartglasses, or XperGuide was similar (3.98 ± 1.68 mm, 5.18 ± 3.84 mm, 4.13 ± 2.38 mm, respectively, p = 0.11). Compared to CBCT-guided fluoroscopy, the smartphone and smartglasses reduced placement time by 38% (p = 0.02) and 55% (p = 0.001), respectively. The DAP for insertion using XperGuide was 3086 ± 2920 mGy*cm2, and no intra-procedural radiation was required for augmented reality. CONCLUSIONS: Smartphone- and smartglasses-based augmented reality reduced needle placement time and radiation exposure while maintaining placement accuracy compared to a clinically validated needle navigation platform.


Asunto(s)
Fluoroscopía/métodos , Imagenología Tridimensional/métodos , Fantasmas de Imagen , Gafas Inteligentes , Teléfono Inteligente , Tomografía Computarizada de Haz Cónico Espiral/métodos , Cirugía Asistida por Computador/métodos , Realidad Aumentada , Humanos
6.
Int J Comput Assist Radiol Surg ; 15(11): 1921-1930, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32734314

RESUMEN

PURPOSE: To compare the system accuracy and needle placement performance of smartphone- and smartglasses-based augmented reality (AR) for percutaneous needle interventions. METHODS: An AR platform was developed to enable the superimposition of annotated anatomy and a planned needle trajectory onto a patient in real time. The system accuracy of the AR display on smartphone (iPhone7) and smartglasses (HoloLens1) devices was evaluated on a 3D-printed phantom. The target overlay error was measured as the distance between actual and virtual targets (n = 336) on the AR display, derived from preprocedural CT. The needle overlay angle was measured as the angular difference between actual and virtual needles (n = 12) on the AR display. Three operators each used the iPhone (n = 8), HoloLens (n = 8) and CT-guided freehand (n = 8) to guide needles into targets in a phantom. Needle placement error was measured with post-placement CT. Needle placement time was recorded from needle puncture to navigation completion. RESULTS: The target overlay error of the iPhone was comparable to the HoloLens (1.75 ± 0.59 mm, 1.74 ± 0.86 mm, respectively, p = 0.9). The needle overlay angle of the iPhone and HoloLens was similar (0.28 ± 0.32°, 0.41 ± 0.23°, respectively, p = 0.26). The iPhone-guided needle placements showed reduced error compared to the HoloLens (2.58 ± 1.04 mm, 3.61 ± 2.25 mm, respectively, p = 0.05) and increased time (87 ± 17 s, 71 ± 27 s, respectively, p = 0.02). Both AR devices reduced placement error compared to CT-guided freehand (15.92 ± 8.06 mm, both p < 0.001). CONCLUSION: An augmented reality platform employed on smartphone and smartglasses devices may provide accurate display and navigation guidance for percutaneous needle-based interventions.


Asunto(s)
Realidad Aumentada , Agujas , Gafas Inteligentes , Teléfono Inteligente , Estudios de Factibilidad , Humanos , Fantasmas de Imagen
7.
Cardiovasc Intervent Radiol ; 43(5): 756-764, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-31915907

RESUMEN

OBJECTIVE: To develop and assess the accuracy of an augmented reality (AR) needle guidance smartphone application. METHODS: A needle guidance AR smartphone application was developed using Unity and Vuforia SDK platforms, enabling real-time displays of planned and actual needle trajectories. To assess the application's accuracy in a phantom, eleven operators (including interventional radiologists, non-interventional radiology physicians, and non-physicians) performed single-pass needle insertions using AR guidance (n = 8) and CT-guided freehand (n = 8). Placement errors were measured on post-placement CT scans. Two interventional radiologists then used AR guidance (n = 3) and CT-guided freehand (n = 3) to navigate needles to within 5 mm of targets with intermediate CT scans permitted to mimic clinical use. The total time and number of intermediate CT scans required for successful navigation were recorded. RESULTS: In the first experiment, the average operator insertion error for AR-guided needles was 78% less than that for CT-guided freehand (2.69 ± 2.61 mm vs. 12.51 ± 8.39 mm, respectively, p < 0.001). In the task-based experiment, interventional radiologists achieved successful needle insertions on each first attempt when using AR guidance, thereby eliminating the need for intraoperative CT scans. This contrasted with 2 ± 0.9 intermediate CT scans when using CT-guided freehand. Additionally, average procedural times were reduced from 13.1 ± 6.6 min with CT-guided freehand to 4.5 ± 1.3 min with AR guidance, reflecting a 66% reduction. CONCLUSIONS: All operators exhibited superior needle insertion accuracy when using the smartphone-based AR guidance application compared to CT-guided freehand. This AR platform can potentially facilitate percutaneous biopsies and ablations by improving needle insertion accuracy, expediting procedural times, and reducing radiation exposures.


Asunto(s)
Realidad Aumentada , Aplicaciones Móviles , Radiografía Intervencional/métodos , Tomografía Computarizada por Rayos X/métodos , Humanos , Agujas , Fantasmas de Imagen , Reproducibilidad de los Resultados , Teléfono Inteligente
8.
Diabetes ; 62(9): 3282-91, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23903356

RESUMEN

Maternal metabolism during pregnancy impacts the developing fetus, affecting offspring birth weight and adiposity. This has important implications for metabolic health later in life (e.g., offspring of mothers with pre-existing or gestational diabetes mellitus have an increased risk of metabolic disorders in childhood). To identify genetic loci associated with measures of maternal metabolism obtained during an oral glucose tolerance test at ∼28 weeks' gestation, we performed a genome-wide association study of 4,437 pregnant mothers of European (n = 1,367), Thai (n = 1,178), Afro-Caribbean (n = 1,075), and Hispanic (n = 817) ancestry, along with replication of top signals in three additional European ancestry cohorts. In addition to identifying associations with genes previously implicated with measures of glucose metabolism in nonpregnant populations, we identified two novel genome-wide significant associations: 2-h plasma glucose and HKDC1, and fasting C-peptide and BACE2. These results suggest that the genetic architecture underlying glucose metabolism may differ, in part, in pregnancy.


Asunto(s)
Secretasas de la Proteína Precursora del Amiloide/genética , Ácido Aspártico Endopeptidasas/genética , Glucemia/genética , Estudio de Asociación del Genoma Completo/métodos , Adolescente , Adulto , Secretasas de la Proteína Precursora del Amiloide/fisiología , Ácido Aspártico Endopeptidasas/fisiología , Péptido C/sangre , Ayuno/sangre , Femenino , Genotipo , Prueba de Tolerancia a la Glucosa , Humanos , Embarazo , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA