Radiology ; 308(1): e230084, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37404154

RESUMEN

Background The triple combination of the cystic fibrosis transmembrane regulator (CFTR) modulators elexacaftor, tezacaftor, and ivacaftor (hereafter, elexacaftor/tezacaftor/ivacaftor) has a positive effect on lung function in patients with cystic fibrosis (CF). Purpose To compare three-dimensional (3D) ultrashort echo time (UTE) MRI functional lung data to common functional lung parameters in assessing lung function in patients with CF undergoing elexacaftor/tezacaftor/ivacaftor therapy. Materials and Methods In this prospective feasibility study, 16 participants with CF consented to undergo pulmonary MRI with a breath-hold 3D UTE sequence at baseline (April 2018-June 2019) and follow-up (April-July 2021). Eight participants received elexacaftor/tezacaftor/ivacaftor after baseline, and eight participants with unchanged treatment served as the control group. Lung function was assessed with body plethysmography and lung clearance index (LCI). Image-based functional lung parameters, such as ventilation inhomogeneity and ventilation defect percentage (VDP), were calculated from signal intensity change between MRI scans at inspiration and expiration. Metrics at baseline and follow-up were compared within groups (permutation test), correlation was tested (Spearman rank correlation), and 95% CIs were calculated (bootstrapping technique). Results MRI ventilation inhomogeneity correlated with LCI at baseline (r = 0.92, P < .001) and follow-up (r = 0.81, P = .002). Mean MRI ventilation inhomogeneity (baseline, 0.74 ± 0.15 [SD]; follow-up, 0.64 ± 0.11; P = .02) and mean VDP (baseline, 14.1% ± 7.4; follow-up, 8.5% ± 3.3; P = .02) decreased from baseline to follow-up in the treatment group. Lung function was stable over time (mean LCI: 9.3 turnovers ± 4.1 at baseline vs 11.5 turnovers ± 7.4 at follow-up; P = .34) in the control group. In all participants, correlation of forced expiratory volume in 1 second with MRI ventilation inhomogeneity was good at baseline (r = -0.61, P = .01) but poor during follow-up (r = -0.06, P = .82). Conclusion Noncontrast 3D UTE lung MRI functional parameters of ventilation inhomogeneity and VDP can be used to assess lung function over time in patients with CF and can add regional information to established global parameters, such as LCI. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Iwasawa in this issue.


Asunto(s)
Fibrosis Quística , Humanos , Fibrosis Quística/diagnóstico por imagen , Fibrosis Quística/tratamiento farmacológico , Regulador de Conductancia de Transmembrana de Fibrosis Quística/genética , Estudios Prospectivos , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Mutación
2.
Acta Radiol ; 64(5): 1851-1858, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36718493

RESUMEN

BACKGROUND: Ultrashort-echo-time (UTE) sequences have been developed to overcome technical limitations of pulmonary magnetic resonance imaging (MRI). Recently, it has been shown that UTE sequences with breath-hold allow rapid image acquisition with sufficient image quality. However, patients with impaired respiration require alternative acquisition strategies while breathing freely. PURPOSE: To compare the diagnostic performance of free-breathing three-dimensional (3D)-UTE sequences with different trajectories based on pulmonary imaging of immunocompromised patients. MATERIAL AND METHODS: In a prospective study setting, two 3D-UTE sequences performed in free-breathing and exploiting non-Cartesian trajectories-one using a stack-of-spirals and the other exploiting a radial trajectory-were acquired at 3 T in patients undergoing hematopoietic stem cell transplantation. Two radiologists assessed the images regarding presence of pleural effusions and pulmonary infiltrations. Computed tomography (CT) was used as reference. RESULTS: A total of 28 datasets, each consisting of free-breathing 3D-UTE MRI with the two sequence techniques and a reference CT scan, were acquired in 20 patients. Interrater agreement was substantial for pulmonary infiltrations using both sequence techniques (κ = 0.77 - 0.78). Regarding pleural effusions, agreement was almost perfect in the stack-of-spirals (κ = 0.81) and moderate in the radial sequence (κ = 0.59). No significant differences in detectability of the assessed pulmonary pathologies were observed between both 3D-UTE sequence techniques (P > 0.05), and their level of agreement was substantial throughout (κ = 0.62-0.81). Both techniques provided high sensitivities and specificities (79%-100%) for the detection of pulmonary infiltrations and pleural effusions compared to reference CT. CONCLUSION: The diagnostic performance of the assessed 3D-UTE MRI sequences was similar. Both sequences enable the detection of typical inflammatory lung pathologies.


Asunto(s)
Imagenología Tridimensional , Derrame Pleural , Humanos , Estudios Prospectivos , Imagenología Tridimensional/métodos , Pulmón/diagnóstico por imagen , Pulmón/patología , Respiración , Imagen por Resonancia Magnética/métodos
3.
Magn Reson Med ; 87(2): 972-983, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34609026

RESUMEN

PURPOSE: Image acquisition and subsequent manual analysis of cardiac cine MRI is time-consuming. The purpose of this study was to train and evaluate a 3D artificial neural network for semantic segmentation of radially undersampled cardiac MRI to accelerate both scan time and postprocessing. METHODS: A database of Cartesian short-axis MR images of the heart (148,500 images, 484 examinations) was assembled from an openly accessible database and radial undersampling was simulated. A 3D U-Net architecture was pretrained for segmentation of undersampled spatiotemporal cine MRI. Transfer learning was then performed using samples from a second database, comprising 108 non-Cartesian radial cine series of the midventricular myocardium to optimize the performance for authentic data. The performance was evaluated for different levels of undersampling by the Dice similarity coefficient (DSC) with respect to reference labels, as well as by deriving ventricular volumes and myocardial masses. RESULTS: Without transfer learning, the pretrained model performed moderately on true radial data [maximum number of projections tested, P = 196; DSC = 0.87 (left ventricle), DSC = 0.76 (myocardium), and DSC =0.64 (right ventricle)]. After transfer learning with authentic data, the predictions achieved human level even for high undersampling rates (P = 33, DSC = 0.95, 0.87, and 0.93) without significant difference compared with segmentations derived from fully sampled data. CONCLUSION: A 3D U-Net architecture can be used for semantic segmentation of radially undersampled cine acquisitions, achieving a performance comparable with human experts in fully sampled data. This approach can jointly accelerate time-consuming cine image acquisition and cumbersome manual image analysis.


Asunto(s)
Corazón , Semántica , Corazón/diagnóstico por imagen , Ventrículos Cardíacos , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Imagen por Resonancia Cinemagnética , Redes Neurales de la Computación
4.
Eur Radiol ; 31(6): 3600-3609, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33280057

RESUMEN

OBJECTIVES: Trauma evaluation of extremities can be challenging in conventional radiography. A multi-use x-ray system with cone-beam CT (CBCT) option facilitates ancillary 3-D imaging without repositioning. We assessed the clinical value of CBCT scans by analyzing the influence of additional findings on therapy. METHODS: Ninety-two patients underwent radiography and subsequent CBCT imaging with the twin robotic scanner (76 wrist/hand/finger and 16 ankle/foot/toe trauma scans). Reports by on-call radiologists before and after CBCT were compared regarding fracture detection, joint affliction, comminuted injuries, and diagnostic confidence. An orthopedic surgeon recommended therapy based on reported findings. Surgical reports (N = 52) and clinical follow-up (N = 85) were used as reference standard. RESULTS: CBCT detected more fractures (83/64 of 85), joint involvements (69/53 of 71), and multi-fragment situations (68/50 of 70) than radiography (all p < 0.001). Six fractures suspected in radiographs were ruled out by CBCT. Treatment changes based on additional information from CBCT were recommended in 29 patients (31.5%). While agreement between advised therapy before CBCT and actual treatment was moderate (κ = 0.41 [95% confidence interval 0.35-0.47]; p < 0.001), agreement after CBCT was almost perfect (κ = 0.88 [0.83-0.93]; p < 0.001). Diagnostic confidence increased considerably for CBCT studies (p < 0.001). Median effective dose for CBCT was 4.3 µSv [3.3-5.3 µSv] compared to 0.2 µSv [0.1-0.2 µSv] for radiography. CONCLUSIONS: CBCT provides advantages for the evaluation of acute small bone and joint trauma by detecting and excluding extremity fractures and fracture-related findings more reliably than radiographs. Additional findings induced therapy change in one third of patients, suggesting substantial clinical impact. KEY POINTS: • With cone-beam CT, extremity fractures and fracture-related findings can be detected and ruled out more reliably than with conventional radiography. • Additional diagnostic information provided by cone-beam CT scans has substantial impact on therapy in small bone and joint trauma. • For distal extremity injury assessment, one-stop-shop imaging without repositioning is feasible with the twin robotic x-ray system.


Asunto(s)
Fracturas Óseas , Procedimientos Quirúrgicos Robotizados , Tomografía Computarizada de Haz Cónico , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/terapia , Humanos , Radiografía , Rayos X
5.
Invest Radiol ; 57(12): 819-825, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-35776435

RESUMEN

OBJECTIVES: Hardening the x-ray beam, tin prefiltration is established for imaging of high-contrast subjects in energy-integrating detector computed tomography (EID-CT). With this work, we aimed to investigate the dose-saving potential of spectral shaping via tin prefiltration in photon-counting detector CT (PCD-CT) of the temporal bone. METHODS: Deploying dose-matched scan protocols with and without tin prefiltration on a PCD-CT and EID-CT system (low-/intermediate-/full-dose: 4.8/7.6-7.7/27.0-27.1 mGy), 12 ultra-high-resolution examinations were performed on each of 5 cadaveric heads. While 120 kVp was applied for standard imaging, the protocols with spectral shaping used the highest potential available with tin prefiltration (EID-CT: Sn 150 kVp, PCD-CT: Sn 140 kVp). Contrast-to-noise ratios and dose-saving potential by spectral shaping were computed for each scanner. Three radiologists independently assessed the image quality of each examination with the intraclass correlation coefficient being computed to measure interrater agreement. RESULTS: Regardless of tin prefiltration, PCD-CT with low (171.2 ± 10.3 HU) and intermediate radiation dose (134.7 ± 4.5 HU) provided less image noise than full-dose EID-CT (177.0 ± 14.2 HU; P < 0.001). Targeting matched image noise to 120 kVp EID-CT, mean dose reduction of 79.3% ± 3.9% could be realized in 120 kVp PCD-CT. Subjective image quality of PCD-CT was better than of EID-CT on each dose level ( P < 0.050). While no distinction was found between dose-matched PCD-CT with and without tin prefiltration ( P ≥ 0.928), Sn 150 kVp EID-CT provided better image quality than 120 kVp EID-CT at high and intermediate dose levels ( P > 0.050). The majority of low-dose EID-CT examinations were considered not diagnostic, whereas PCD-CT scans of the same dose level received satisfactory or better ratings. Interrater reliability was excellent (intraclass correlation coefficient 0.903). CONCLUSIONS: PCD-CT provides superior image quality and significant dose savings compared with EID-CT for ultra-high-resolution examinations of the temporal bone. Aiming for matched image noise, high-voltage scan protocols with tin prefiltration facilitate additional dose saving in EID-CT, whereas superior inherent denoising decreases the dose reduction potential of spectral shaping in PCD-CT.


Asunto(s)
Fotones , Estaño , Humanos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/métodos , Hueso Temporal
6.
Rofo ; 194(1): 39-48, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34649285

RESUMEN

PURPOSE: To evaluate the feasibility of non-contrast-enhanced three-dimensional ultrashort echo time (3D-UTE) MRI for pulmonary imaging in immunocompromised patients during hematopoietic stem cell transplantation (HSCT). METHODS: MRI was performed using a stack-of-spirals 3D-UTE sequence (slice thickness: 2.34mm; matrix: 256 × 256; acquisition time: 12.7-17.6 seconds) enabling imaging of the entire thorax within single breath-holds. Patients underwent MRI before HSCT initiation, in the case of periprocedural pneumonia, before discharge, and in the case of re-hospitalization. Two readers separately assessed the images regarding presence of pleural effusions, ground glass opacities (GGO), and consolidations on a per lung basis. A T2-weighted (T2w) multi-shot Turbo Spin Echo sequence (BLADE) was acquired in coronal orientation during breath-hold (slice thickness: 6.00mm; matrix: 320 × 320; acquisition time: 3.1-5.5 min) and read on a per lesion basis. Low-dose CT scans in inspiration were used as reference and were read on a per lung basis. Only scans performed within a maximum of three days were included in the inter-method analyses. Interrater agreement, sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy of 3D-UTE MRI were calculated. RESULTS: 67 MRI scans of 28 patients were acquired. A reference CT examination was available for 33 scans of 23 patients. 3D-UTE MRI showed high sensitivity and specificity regarding pleural effusions (n = 6; sensitivity, 92 %; specificity, 100 %) and consolidations (n = 22; sensitivity 98 %, specificity, 86 %). Diagnostic performance was lower for GGO (n = 9; sensitivity, 63 %; specificity, 84 %). Accuracy rates were high (pleural effusions, 98 %; GGO, 79 %; consolidations 94 %). Interrater agreement was substantial for consolidations and pleural effusions (κ = 0.69-0.82) and moderate for GGO (κ = 0.54). Compared to T2w imaging, 3D-UTE MRI depicted the assessed pathologies with at least equivalent quality and was rated superior regarding consolidations and GGO in ~50 %. CONCLUSION: Non-contrast 3D-UTE MRI enables radiation-free assessment of typical pulmonary complications during HSCT procedure within a single breath-hold. Yet, CT was found to be superior regarding the identification of pure GGO changes. KEY POINTS: · 3D-UTE MRI of the thorax can be acquired within a single breath-hold.. · 3D-UTE MRI provides diagnostic imaging of pulmonary consolidations and pleural effusions.. · 3D-UTE sequences improve detection rates of ground glass opacities on pulmonary MRI.. · 3D-UTE MRI depicts pulmonary pathologies at least equivalent to T2-weighted Blade sequence.. CITATION FORMAT: · Metz C, Böckle D, Heidenreich JF et al. Pulmonary Imaging of Immunocompromised Patients during Hematopoietic Stem Cell Transplantation using Non-Contrast-Enhanced Three-Dimensional Ultrashort Echo Time (3D-UTE) MRI. Fortschr Röntgenstr 2022; 194: 39 - 48.


Asunto(s)
Trasplante de Células Madre Hematopoyéticas , Imagenología Tridimensional , Humanos , Huésped Inmunocomprometido , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética
7.
Invest Radiol ; 56(12): 785-790, 2021 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-33882030

RESUMEN

OBJECTIVES: Detailed visualization of bone microarchitecture is essential for assessment of wrist fractures in computed tomography (CT). This study aims to evaluate the imaging performance of a CT system with clinical cadmium telluride-based photon-counting detector (PCD-CT) compared with a third-generation dual-source CT scanner with energy-integrating detector technology (EID-CT). MATERIALS AND METHODS: Both CT systems were used for the examination of 8 cadaveric wrists with radiation dose equivalent scan protocols (low-/standard-/full-dose imaging: CTDIvol = 1.50/5.80/8.67 mGy). All wrists were scanned with 2 different operating modes of the photon-counting CT (standard-resolution and ultra-high-resolution). After reformatting with comparable reconstruction parameters and convolution kernels, subjective evaluation of image quality was performed by 3 radiologists on a 7-point scale. For estimation of interrater reliability, we report the intraclass correlation coefficient (absolute agreement, 2-way random-effects model). Signal-to-noise and contrast-to-noise ratios were calculated to provide semiquantitative assessment of image quality. RESULTS: Subjective image quality of standard-dose PCD-CT examinations in ultra-high-resolution mode was superior compared with full-dose PCD-CT in standard-resolution mode (P = 0.016) and full-dose EID-CT (P = 0.040). No difference was ascertained between low-dose PCD-CT in ultra-high-resolution mode and standard-dose scans with either PCD-CT in standard-resolution mode (P = 0.108) or EID-CT (P = 0.470). Observer evaluation of standard-resolution PCD-CT and EID-CT delivered similar results in full- and standard-dose scans (P = 0.248/0.509). Intraclass correlation coefficient was 0.876 (95% confidence interval, 0.744-0.925; P < 0.001), indicating good reliability. Between dose equivalent studies, signal-to-noise and contrast-to-noise ratios were substantially higher in photon-counting CT examinations (all P's < 0.001). CONCLUSIONS: Superior visualization of fine anatomy is feasible with the clinical photon-counting CT system in cadaveric wrist scans. The ultra-high-resolution scan mode suggests potential for considerable dose reduction over energy-integrating dual-source CT.


Asunto(s)
Tomografía Computarizada por Rayos X , Muñeca , Cadáver , Compuestos de Cadmio , Humanos , Fantasmas de Imagen , Fotones , Reproducibilidad de los Resultados , Telurio , Tomografía Computarizada por Rayos X/métodos