1.
Ann Cardiol Angeiol (Paris) ; 72(5): 101662, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37742408

RESUMEN

Premature ventricular contractions (PVCs) are common. Although often benign, they can also be associated with increased morbidity and mortality. The aim of this review was to assess the risk evaluation of PVCs in patients with or without structural heart disease and discuss the management of this arrhythmia. Reports published in English were searched in PubMed with the following search terms: premature ventricular contraction, ectopic ventricular beat, ventricular extrasystole, antiarrhythmic drugs, ablation, ventricular arrhythmia, ventricular tachycardia, ventricular fibrillation and torsade de pointe. This analysis suggests that all patients with frequent PVCs should be assessed for PVC burden, symptom status and the presence of structural heart disease. PVCs in patients with structurally normal hearts was once considered a benign phenomenon. Uncommonly, PVCs may provoke life-threatening arrhythmias. Ventricular fibrillation is the initial mode of malignant rapid ventricular arrhythmias (MRVAs). Patients with malignant PVC and PVC burden >10% are at increased risk of MRVA in case of myocardial infarction and heart failure. MRVA is the primary cause of sudden cardiac death in patients with and without structural heart disease. Therapeutic options include medical therapy and catheter ablation, the latter more effective and potentially curable, particularly in patients with left ventricular dysfunction. The timely recognition and effective treatment of malignant PVCs in symptomatic patients with underling cardiomyopathy are mandatory to initiate early therapies before the occurrence of adverse clinical outcomes and to improve the long-term prognosis.

2.
Ann Endocrinol (Paris) ; 82(3-4): 132-133, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32171470

RESUMEN

BACKGROUND: Male hypogonadism, arising from a range of etiologies including androgen-deprivation therapies (ADTs), has been reported as a risk factor for acquired long-QT syndrome (aLQTS) and torsades de pointes (TdP). A full description of the clinical features of aLQTS associated with ADT and of underlying mechanisms is lacking. METHODS: We searched the international pharmacovigilance database VigiBase for men (n=6 560 565 individual case safety reports) presenting with aLQTS, TdP, or sudden death associated with ADT. In cardiomyocytes derived from induced pluripotent stem cells from men, we studied electrophysiological effects of ADT and dihydrotestosterone. RESULTS: Among subjects receiving ADT in VigiBase, we identified 184 cases of aLQTS (n=168) and/or TdP (n=68; 11% fatal), and 99 with sudden death. Of the 10 ADT drugs examined, 7 had a disproportional association (reporting odds ratio=1.4-4.7; P<0.05) with aLQTS, TdP, or sudden death. The minimum and median times to sudden death were 0.25 and 92 days, respectively. The androgen receptor antagonist enzalutamide was associated with more deaths (5430/31 896 [17%]; P<0.0001) than other ADT used for prostate cancer (4208/52 089 [8.1%]). In induced pluripotent stem cells, acute and chronic enzalutamide (25µM) significantly prolonged action potential durations (action potential duration at 90% when paced at 0.5Hz; 429.7±27.1 (control) versus 982.4±33.2 (acute, P<0.001) and 1062.3±28.9ms (chronic; P<0.001), and generated afterdepolarizations and/or triggered activity in drug-treated cells (11/20 acutely and 8/15 chronically). Enzalutamide acutely and chronically inhibited delayed rectifier potassium current, and chronically enhanced late sodium current. Dihydrotestosterone (30nM) reversed enzalutamide electrophysiological effects on induced pluripotent stem cells. CONCLUSION: QT prolongation and TdP are a risk in men receiving enzalutamide and other ADTs. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03193138.


Asunto(s)
Dihidrotestosterona/farmacología , Miocitos Cardíacos/efectos de los fármacos , Función Ventricular/efectos de los fármacos , Andrógenos/farmacología , Andrógenos/uso terapéutico , Diferenciación Celular/efectos de los fármacos , Diferenciación Celular/fisiología , Células Cultivadas , Bases de Datos Factuales , Muerte Súbita Cardíaca/epidemiología , Dihidrotestosterona/uso terapéutico , Fenómenos Electrofisiológicos/efectos de los fármacos , Eunuquismo/tratamiento farmacológico , Eunuquismo/epidemiología , Eunuquismo/fisiopatología , Ventrículos Cardíacos/efectos de los fármacos , Ventrículos Cardíacos/fisiopatología , Humanos , Células Madre Pluripotentes Inducidas/efectos de los fármacos , Células Madre Pluripotentes Inducidas/fisiología , Internacionalidad , Síndrome de QT Prolongado/inducido químicamente , Síndrome de QT Prolongado/epidemiología , Síndrome de QT Prolongado/patología , Síndrome de QT Prolongado/fisiopatología , Masculino , Potenciales de la Membrana/efectos de los fármacos , Miocitos Cardíacos/patología , Farmacovigilancia , Torsades de Pointes/inducido químicamente , Torsades de Pointes/epidemiología , Torsades de Pointes/patología , Torsades de Pointes/fisiopatología , Investigación Biomédica Traslacional
3.
Int J Cardiol ; 258: 172-178, 2018 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-29544927

RESUMEN

INTRODUCTION: The prognosis of pregnancy in patients with Arrhythmogenic Right Ventricular Cardiomyopathy/dysplasia (ARVC/D) is poorly documented. The aim of this study is to assess the cardiac risks during pregnancy and the impact of ARVC/D on fetuses/neonates/children. METHODS: We included all ARVC/D women with a history of pregnancy from the ARVC/D Pitié-Salpêtrière registry. Cardiac and obstetrical events having occurred during pregnancy/delivery/post-partum periods and neonatal data/follow-up were collected. RESULTS: Sixty pregnancies in twenty-three patients were identified between 1968 and 2016. Only two major non-fatal cardiac events (one sustained non-documented tachycardia and one ventricular tachycardia) were recorded during pregnancy in two different mothers (3% of pregnancies, 9% of mothers). None occurred during delivery or in the postpartum period. No mother developed heart failure. Beta-blocker therapy during pregnancy (n=15) was associated with lower birthweight (2730 vs 3400g, p=0.004). Only two preterm deliveries occurred, unrelated to cardiac condition. Caesarean section was performed in 13% of cases. Premature sudden-death occurred in 10% (n=5) of children before 25years-old including two in the first year of life. CONCLUSION: ARVC/D is associated with a low rate of major cardiac events during pregnancy and vaginal delivery appears safe. The risk of sustained ventricular arrhythmia seems poorly predictable and supports the continuation of beta-blockers during pregnancy. Major cardiac events were frequent in childhood, justifying close cardiac monitoring.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica/diagnóstico por imagen , Displasia Ventricular Derecha Arritmogénica/epidemiología , Complicaciones Cardiovasculares del Embarazo/diagnóstico por imagen , Complicaciones Cardiovasculares del Embarazo/epidemiología , Resultado del Embarazo/epidemiología , Aborto Espontáneo/diagnóstico por imagen , Aborto Espontáneo/epidemiología , Aborto Espontáneo/prevención & control , Antagonistas Adrenérgicos beta/uso terapéutico , Adulto , Displasia Ventricular Derecha Arritmogénica/tratamiento farmacológico , Femenino , Humanos , Recién Nacido , Persona de Mediana Edad , Embarazo , Complicaciones Cardiovasculares del Embarazo/tratamiento farmacológico , Nacimiento Prematuro/diagnóstico por imagen , Nacimiento Prematuro/epidemiología , Nacimiento Prematuro/prevención & control , Estudios Retrospectivos , Adulto Joven
4.
Int J Cardiol ; 236: 216-220, 2017 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-28237734

RESUMEN

BACKGROUND: Atrioventricular block (AVB) is common after transcatheter aortic valve replacement (TAVR) and permanent pacemaker (PPM) implantation is needed in up to 30% of patients. Main predictors of long term AVB are electrocardiographic. The purpose of this study is to assess the prognostic value of serial HV intervals measured before and after TAVR to shorten the timing of PPM implantation. METHODS: His bundle recordings were performed before (HV1), immediately after TAVR (HV2) and at day 2 for Edwards Sapien (ES) and 5 for Medtronic CoreValve (CV) (HV3). PPM indications were high degree AVB before day 5 or prolonged HV interval ≥80ms at the last recording. High degree AVB after discharge was evaluated from the pacemaker memories and ECG at 1 and 6months. RESULTS: Data were obtained in 84 patients (33% CV and 67% ES). HV values were not associated with early or late AVB. PPM were implanted in 27 patients (34%) for documented AVB (n=17, 24%), prolonged HV interval (n=9) or sick sinus syndrome (n=1). Persistent complete AVB during the procedure and postoperative high degree AVB were the only perioperative factors associated with further long term occurrence of high degree AVB (p=0.001 and p<0.001). On multivariate analysis, only postoperative high degree AVB was significant (p=0.001). CONCLUSION: Pre- and post-operative HV measurements were not correlated with late AVB after TAVR. Perioperative persistent complete AVB and postoperative high degree AVB are the only factors to predict late AVB and should be considered for the decision of PPM implantation.


Asunto(s)
Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/fisiopatología , Fascículo Atrioventricular/fisiopatología , Electrocardiografía/métodos , Reemplazo de la Válvula Aórtica Transcatéter/tendencias , Anciano , Anciano de 80 o más Años , Electrocardiografía/tendencias , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Prospectivos , Sistema de Registros , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
5.
Arch Mal Coeur Vaiss ; 99(10): 871-5, 2006 Oct.
Artículo en Francés | MEDLINE | ID: mdl-17100136

RESUMEN

UNLABELLED: A survey into the implantation of cardiac pacemakers during 2001 in the Ile-de-France area was carried out by the French National Insurance Medical Service in order to evaluate performance in all centres performing more than 10 primary implantations per year. METHODS AND RESULTS: In 2001, 12 centres out of a total of 49 performed less than 50 primary implantations per year, representing 5% of the total regional activity, which was estimated to be 6414 procedures. The remaining 95% of procedures were spread evenly among 8 high-throughput centres (> 200 primary implantations per year) and 29 medium-throughput centres (50 to 200 primary implantations per year). Indications for pacing were analysed retrospectively by a team of regulatory doctors on a sample of 2176 patients with reference to the ACC/AHA/NASPE guidelines. After examination of the medical records, the indication was ranked as being class I, II or Ill (absence of indication). A valid indication was lacking in 8.2% of cases. Sinus node dysfunction represented 74.6% of the non-indications, and this classification had the predictive factors of asymptomatic dysfunction, and treatment with anti-arrhythmic or bradycardic medication. The proportion of class III interventions was significantly lower in the high-throughput centres (5.8 vs 9.9%, p < 0.05). CONCLUSION: 8.2% of primary pacing procedures were not indicated and resulted principally from asymptomatic sinus node dysfunction.


Asunto(s)
Estimulación Cardíaca Artificial/estadística & datos numéricos , Anciano , Femenino , Humanos , Masculino , Paris , Estudios Retrospectivos , Encuestas y Cuestionarios
6.
J Interv Card Electrophysiol ; 3(2): 169-72, 1999 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-10387132

RESUMEN

INTRODUCTION: During radiofrequency catheter ablation of a common atrial flutter between the tricuspid annulus and the Eustachian valve "septal isthmus", double potentials were recorded along the Eustachian valve, previously described as an anatomical line of conduction block between the coronary sinus ostium and the inferior vena cava. RESULTS: Just before flutter termination, lengthening and beat to beat delay variations between the 2 components of the double potentials were correlated with simultaneous modifications of the flutter cycle length. CONCLUSION: The "septal isthmus" is a common pathway for the flutter wavefront and the impulse generating the second component of the double potential. It is also a good target for flutter ablation.


Asunto(s)
Aleteo Atrial/fisiopatología , Aleteo Atrial/cirugía , Ablación por Catéter , Vena Cava Inferior/fisiopatología , Adulto , Electrocardiografía , Humanos , Masculino
7.
Arch Mal Coeur Vaiss ; 93(7): 865-8, 2000 Jul.
Artículo en Francés | MEDLINE | ID: mdl-10975039

RESUMEN

The authors report the case of a young man with idiopathic ventricular tachycardia occurring in bursts and arising from the pulmonary infundibulum. During follow-up, progressive, severe, dilated cardiomyopathy was observed. Radiofrequency ablation of the site of origin of this very active arrhythmia resulted in total regression of the cardiomyopathy. Contrary to generally accepted concepts, paroxystic ventricular tachycardia, usually qualified as benign, may be complicated by cardiomyopathy when the ventricular extrasystole is incessant and repetitive.


Asunto(s)
Cardiomiopatía Dilatada/etiología , Taquicardia Ventricular/complicaciones , Adulto , Ablación por Catéter , Electrofisiología , Humanos , Masculino , Taquicardia Ventricular/cirugía , Resultado del Tratamiento
8.
Arch Mal Coeur Vaiss ; 96 Spec No 3: 46-9, 2003 Apr.
Artículo en Francés | MEDLINE | ID: mdl-12741332

RESUMEN

The IRM is formally contraindicated to the pacemaker and cardiac defibrillator wearers because of the risk of inhibition or inappropriate stimulations during the examination. However if the examination is essential, suitable programming of the apparatus and a constant monitoring of the heartbeat rate by a qualified doctor in cardiac stimulation must make it possible to avoid any accident.


Asunto(s)
Desfibriladores Implantables , Campos Electromagnéticos , Marcapaso Artificial , Ondas de Radio/efectos adversos , Humanos
9.
Arch Mal Coeur Vaiss ; 96 Spec No 3: 35-41, 2003 Apr.
Artículo en Francés | MEDLINE | ID: mdl-12741330

RESUMEN

UNLABELLED: The effect of 50 Hz and 60 Hz (frequencies of current distribution) and 20 kHz to 50 kHz (frequencies of induction cooktop) magnetic interference on implanted pacemakers have been assessed with the present generation of device technology. Sixty patients implanted in 1998 and 1999 with dual chamber pacemakers from 9 different manufacturers were monitored with telemetry while passing through, and standing between a system of two coils. They generated a 50 Hz or a 60 Hz magnetic field at 50 microT. Then, patients used a cooktop at different power. The recordings were made with the standard setting of "medically correct" sensing parameters chosen for the patients. Then pacemakers were reprogrammed to the unipolar mode, with the highest atrial (A) and ventricular (V) sensitivity that did not induce muscular inhibition while moving. Between each exposure (50 Hz, 60 Hz or 20 kHz to 50 kHz), the pacemaker programmation was controlled. At the end of the tests, pacemakers will be reprogrammed with the standard setting. The medical observer being blind to the existence or not of the magnetic field. No pacemaker was influenced by the vicinity of the magnetic field at medically correct settings. At unipolar high sensitivity, no inhibition nor reprogramming was observed. Transient reversion to interference mode was observed in 6 cases, 3 transient acceleration due to atrial detection of the interference, and one T wave detection by the ventricular lead. All were observed with the 60 Hz, and only 3 with the 50 Hz magnetic field. One device (Biotronik) shifted out of its special program (hysteresis research) during the tests with the induction cooktop, but it maintained its standard program, and the event could not be repeated despite further testing. CONCLUSION: Actual pacemakers do not present any electromagnetic interference with 50 Hz and 60 Hz or induction cooktop frequency working. They are insensitive with medically correct settings. Unusual high sensitivity leads only to noise reversion mode, or transient ventricular tracking.


Asunto(s)
Campos Electromagnéticos , Marcapaso Artificial , Relación Dosis-Respuesta en la Radiación , Diseño de Equipo , Humanos , Monitoreo Fisiológico , Marcapaso Artificial/efectos adversos , Ondas de Radio , Telemetría
10.
Arch Pediatr ; 10(1): 38-41, 2003 Jan.
Artículo en Francés | MEDLINE | ID: mdl-12818779

RESUMEN

UNLABELLED: In children, Wolff-Parkinson-White (WPW) syndrome is often revealed by reentrant tachycardia episodes. Rarely, this syndrome can be the cause of syncope or of sudden death, resulting from rapid conduction of atrial fibrillation to the ventricles through the accessory pathway. CASE REPORT: The authors report the case of a child, who had a WPW syndrome diagnosed after birth because of a supraventricular tachycardia and who was later asymptomatic. At ten years of age, he was admitted because of palpitations due to atrial fibrillation and rapid conduction through the accessory pathway. CONCLUSION: In a child with WPW syndrome, tachycardia with wide and irregular QRS complexes should evoke the involvement of atrial fibrillation, with rapid conduction to the ventricle. Drugs blocking conduction through the atrio-ventricular node are contra-indicated and the condition is an indication for radiofrequency ablation.


Asunto(s)
Fibrilación Atrial/etiología , Síndrome de Wolff-Parkinson-White/complicaciones , Niño , Electrocardiografía , Humanos , Lactante , Masculino
11.
Ann Cardiol Angeiol (Paris) ; 49(4): 238-44, 2000 Jul.
Artículo en Francés | MEDLINE | ID: mdl-12555485

RESUMEN

Cardiac pacemaker are sensitive to many kind of electromagnetic interference (EMI). However the low rate of reported effects is due to many protective features. Risks are minimal in everyday life conditions as airport detectors, electronic anti-thief systems, domestic electrical appliances and even mobile phones with the most recent models. Interference detection can be prevented by "medically correct" setting, with the use of bipolar sensing, and ventricular sensitivity above 2 mV. The effect of EMI from the industrial world are difficult to assess and need an individual study. The most important risks occur in the medical world, with the electrocutary, thransthoracic DC shocks, and magnetic resonance imaging.


Asunto(s)
Campos Electromagnéticos , Marcapaso Artificial , Campos Electromagnéticos/efectos adversos , Diseño de Equipo , Falla de Equipo , Humanos , Factores de Riesgo
13.
Heart ; 97(10): 844-9, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21378009

RESUMEN

BACKGROUND: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is an inherited heart disease in which mutations affecting Plakophilin-2 (PKP2) are the most frequently detected. However, pathogenicity of variants is not always fully determined. PKP2 encodes two isoforms, the longest (PKP2b) includes the alternatively spliced exon 6, which is routinely screened for molecular diagnosis, despite the absence of data on cardiac expression of PKP2 isoforms. OBJECTIVE: To examine the pathogenicity of PKP2 exon 6 mutations by focusing on a missense variant located in this exon. METHODS AND RESULTS: The PKP2 heterozygous p.Arg490Trp variant was identified in two unrelated ARVC probands (absent from 470 controls). In silico analysis suggested that PKP2 exon 6 is an Alu-derived sequence with very low expression level. PKP2a mRNA, which does not include the sequence encoded by exon 6, was the dominant isoform transcribed; at western blot analysis PKP2A was the only clearly detectable isoform in all human heart samples analysed (from six different controls and the proband). Moreover, in the proband's sample, p.Arg490Trp was not associated with aberrant exon 6 splicing or mutant mRNA downregulation. Finally, a heterozygous missense variant (p.Glu2343Lys) in Desmoplakin was identified in this proband and is likely to be the disease-causing mutation. CONCLUSION: PKP2A was shown to be the major isoform expressed in human heart tissue and PKP2B protein was undetectable. The results strongly suggest that p.Arg490Trp and other variants located in PKP2 exon 6 may not be disease causing. Variant splicing also has important consequences for the interpretation of mutation analysis and genetic counselling in ARVC and other hereditary cardiac diseases.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica/genética , Pruebas Genéticas/métodos , Mutación Missense/genética , Placofilinas/genética , Adulto , Displasia Ventricular Derecha Arritmogénica/diagnóstico , Western Blotting , Femenino , Heterocigoto , Humanos , Masculino , Miocardio/metabolismo , Placofilinas/metabolismo , Isoformas de Proteínas/genética , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa
15.
Pacing Clin Electrophysiol ; 23(11 Pt 2): 1798-800, 2000 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11139927

RESUMEN

Active-fixation pacemaker leads enable pacing at various sites, have a low dislodgment rate, and are easier to extract than passive-fixation leads, though are usually not routinely implanted in the ventricle because of their higher pacing threshold. The long-term pacing threshold associated with an active-fixation steroid-eluting lead was prospectively measured in 18 women and 20 men. At a mean follow-up of 14 months (range 3-25 months), pacing threshold increased from 0.71 +/- 0.29 V to 0.96 +/- 0.28 V (P = 0.01) between implant and the first month of follow-up, then remained stable over time, consistently allowing the long-term programming of the ventricular output at 2.5 V, while lead impedance remained stable (from 647 +/- 161 omega at implant to 666 +/- 122 omega at last follow-up). If the long-term performance of this type of lead is confirmed, the routine implantation of ventricular steroid-eluting active-fixation leads should be considered since lead extraction has become a major concern.


Asunto(s)
Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial/métodos , Dexametasona/análogos & derivados , Electrodos Implantados/normas , Ventrículos Cardíacos/cirugía , Marcapaso Artificial , Adulto , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/fisiopatología , Enfermedad Crónica , Dexametasona/administración & dosificación , Implantes de Medicamentos , Femenino , Estudios de Seguimiento , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Umbral Sensorial , Resultado del Tratamiento
16.
Pacing Clin Electrophysiol ; 19(5): 752-7, 1996 May.
Artículo en Inglés | MEDLINE | ID: mdl-8734741

RESUMEN

The purpose of the current study was to characterize the effects of transvenous ICD shocks on myocardial impedance. Rather than recording impedance during shocks, it was measured during continuous pacing in order to minimize confounding effects such as electrode polarization. Pacing impedance (reflecting the combined impedances of the electrode-tissue interface, myocardium, and blood pool) was measured every 5 seconds before and after 58 single shocks in 22 patients undergoing ICD implantation with a Transvene (n = 14) or Endotak (n = 8) lead. There was a progressive and long-lasting decrease in impedance after shocks. The magnitude of this change was similar for 0.6-J test shocks and shocks > or = 5 J (28 +/- 32 omega vs 23 +/- 16 omega; P = 0.8). However, the drop in impedance was more abrupt after high energy shocks. Because impedance continued to decline throughout the 5-minute interval between shocks, successive shocks had a cumulative effect, with a decrease of 46 +/- 42 omega after four discharges. In conclusion, a progressive decline in pacing impedance is a characteristic response to transvenous ICD discharges.


Asunto(s)
Estimulación Cardíaca Artificial , Desfibriladores Implantables , Corazón/fisiología , Adulto , Anciano , Antiarrítmicos/uso terapéutico , Sangre , Factores de Confusión Epidemiológicos , Conductividad Eléctrica , Impedancia Eléctrica , Electrodos Implantados , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores de Tiempo
17.
Curr Cardiol Rep ; 2(6): 498-506, 2000 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11203287

RESUMEN

Arrhythmogenic right ventricular dysplasia (ARVD) is a structural heart disease affecting young adults that leads to cardiac rhythm disorders including supraventricular and mostly ventricular arrhythmias. Sudden death may be the first presentation of the disease. Ablation techniques have been used for the treatment of ventricular tachycardia in cases resistant to drug therapy. Radiofrequency is appropriate as a first approach for ventricular tachycardia ablation in ARVD; however, its effectiveness is less than 40% at the first session. Fulguration is effective for ventricular tachy-cardia ablation and should be used in the same session after ineffective radiofrequency ablation. However, fulguration requires expertise, general anesthesia, and more than one session in half of all patients. Radiofrequency and fulguration plus other common forms of treatment including pacemakers and automatic implantable cardioverter defibrillators provides a clinical success rate of 81% to 93% in a series of 50 consecutive patients studied during 16 years. Earlier poor reputation of fulguration was the result of poorly understood technical problems concerning the physics and biophysics of the procedure under control with presently available methods. This in-depth study of a large population over a long time period demonstrates that fulguration should be rehabilitated.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica/complicaciones , Ablación por Catéter/métodos , Taquicardia Ventricular/cirugía , Adolescente , Adulto , Anciano , Displasia Ventricular Derecha Arritmogénica/diagnóstico , Displasia Ventricular Derecha Arritmogénica/mortalidad , Electrocardiografía , Femenino , Estudios de Seguimiento , Pruebas de Función Cardíaca , Hemodinámica/fisiología , Humanos , Masculino , Persona de Mediana Edad , Probabilidad , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Tasa de Supervivencia , Taquicardia Ventricular/etiología , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA