Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Biosensors (Basel) ; 14(6)2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38920590

RESUMEN

A tetherless multi-targeted bioimpedance device was designed, modeled, built, and tested for measuring arterial pulse and, using morphological analysis, its potential for monitoring blood flow restrictions that mimic Peripheral Artery Disease (PAD) was assessed across multiple peripheral arteries. Specifically, we first developed a small form factor, tetherless, bioimpedance device, based on high-frequency structure simulator (HFSS) simulations. After designing and building the device we then tested it in vivo on human subjects on multiple arteries and found that we did not need to modify the gain on the device compared to the bench top system. Further, it was found that changes in the morphology of the bioimpedance signal over time, depicted through the ratio of the first and second harmonic in the signal frequency, could be used to predict blood flow restrictions that mimic peripheral artery disease (PAD). The HFSS simulations helped guide the modulation frequency selection and the placement of the bioimpedance electrodes. We built the device and compared it to two commercially available bioimpedance devices and it was shown to demonstrate a distinct advantage in its multi-target capability, enabling more accurate pulse measurements from different arteries without the need for tuning the circuit for each artery. Comparing the ratio of the 1st and 2nd harmonics as a function of the blood flow restriction, the two commercial devices showed a maximum error across arteries of between 22% and 27% depending on the measurement location, whereas our system consistently displayed a stable value of just below 4%. With this system, there is the potential for comprehensive and personalized medical examinations for PAD at the point of care (POC).


Asunto(s)
Impedancia Eléctrica , Enfermedad Arterial Periférica , Humanos , Enfermedad Arterial Periférica/fisiopatología , Progresión de la Enfermedad
2.
Biosensors (Basel) ; 14(2)2024 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-38392011

RESUMEN

Pulse Wave Velocity (PWV) analysis is valuable for assessing arterial stiffness and cardiovascular health and potentially for estimating blood pressure cufflessly. However, conventional PWV analysis from two transducers spaced closely poses challenges in data management, battery life, and developing the device for continuous real-time applications together along an artery, which typically need data to be recorded at high sampling rates. Specifically, although a pulse signal consists of low-frequency components when used for applications such as determining heart rate, the pulse transit time for transducers near each other along an artery takes place in the millisecond range, typically needing a high sampling rate. To overcome this issue, in this study, we present a novel approach that leverages the Nyquist-Shannon sampling theorem and reconstruction techniques for signals produced by bioimpedance transducers closely spaced along a radial artery. Specifically, we recorded bioimpedance artery pulse signals at a low sampling rate, reducing the data size and subsequently algorithmically reconstructing these signals at a higher sampling rate. We were able to retain vital transit time information and achieved enhanced precision that is comparable to the traditional high-rate sampling method. Our research demonstrates the viability of the algorithmic method for enabling PWV analysis from low-sampling-rate data, overcoming the constraints of conventional approaches. This technique has the potential to contribute to the development of cardiovascular health monitoring and diagnosis using closely spaced wearable devices for real-time and low-resource PWV assessment, enhancing patient care and cardiovascular disease management.


Asunto(s)
Arterias , Análisis de la Onda del Pulso , Humanos , Arterias/fisiología , Presión Sanguínea , Frecuencia Cardíaca
3.
Micromachines (Basel) ; 15(7)2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-39064418

RESUMEN

Conventional dry electrodes often yield unstable results due to the presence of parasitic capacitance between the flat electrode surface and the non-uniform skin interface. To address this issue, a gel is typically placed between the electrodes to minimize parasitic capacitance. However, this approach has the drawbacks of being unsuitable for repeated use, limited lifetime due to gel evaporation, and the possibility of developing skin irritation. This is particularly problematic in underserved areas since, due to the cost of disposable wet electrodes, they often sterilize and reuse dry electrodes. In this study, we propose a method to neutralize the effects of parasitic capacitance by attaching high-value capacitors to the electrodes in parallel, specifically when applied to pulse wave monitoring through bioimpedance. Skin capacitance can also be mitigated due to the serial connection, enabling stable reception of arterial pulse signals through bioimpedance circuits. A high-frequency structure simulator (HFSS) was first used to simulate the capacitance when injection currents flow into the arteries through the bioimpedance circuits. We also used the simulation to investigate the effects of add-on capacitors. Lastly, we conducted preliminary comparative analyses between wet electrodes and dry electrodes in vivo with added capacitance values ranging from 100 pF to 1 µF, altering capacitance magnitudes by factors of 100. As a result, we obtained a signal-to-noise ratio (SNR) that was 8.2 dB higher than that of dry electrodes. Performance was also shown to be comparable to wet electrodes, with a reduction of only 0.4 dB using 1 µF. The comparative results demonstrate that the addition of capacitors to the electrodes has the potential to allow for performance similar to that of wet electrodes for bioimpedance pulse rate monitoring and could potentially be used for other applications of dry electrodes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA