Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Doc Ophthalmol ; 148(1): 15-24, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37749441

RESUMEN

PURPOSE: To correlate multifrequency pattern reversal VEPs in quadrants (QmfrVEPs) with perimetric field losses for objective detection of visual field losses. METHODS: QmfrVEP measurements were performed using four LED-based checkerboard stimulators to stimulate the four quadrants of the visual field. QmfrVEPs were measured monocularly in 5 normal subjects and in 5 glaucoma patients who showed losses in conventional Octopus perimetry. The pattern reversal frequency varied slightly between the stimulators: (11.92, 12.00, 12.08 and 12.16 reversals/sec). The responses to the different stimuli were identified by discrete Fourier analysis. VEPs were recorded using different electrode configurations, and the recording with the highest signal-to-noise ratio (SNR) was used for further analysis. RESULTS: QmfrVEP responses from the different quadrants can be reliably measured and separated using the 0.08 reversals/sec interstimulus reversal frequency differences. The signal-to-noise ratio in the four quadrants was significantly correlated with the equivalent visual field losses obtained with perimetry (Spearman rank correlation: P < 0.001). In the five glaucoma patients, the SNR was reduced in 15 out of the 16 quadrants with a perimetric defect, in comparison to the results in quadrants of healthy subjects. This confirms the sensitivity of the procedure. CONCLUSION: QmfrVEP responses can be measured reliably. This pilot study suggests that high SNR values exclude visual field defects and that focal defects can be identified in glaucoma patients. TRIAL REGISTRATION: www. CLINICALTRIALS: gov . NCT00494923.


Asunto(s)
Glaucoma , Pruebas del Campo Visual , Humanos , Pruebas del Campo Visual/métodos , Campos Visuales , Proyectos Piloto , Electrorretinografía , Trastornos de la Visión/diagnóstico , Glaucoma/diagnóstico , Potenciales Evocados Visuales
2.
Graefes Arch Clin Exp Ophthalmol ; 262(5): 1607-1618, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38183466

RESUMEN

PURPOSE: Estimating glaucoma suspects' risk for visual field defects helps to avoid under- and over-treatment. In this retrospective, longitudinal cohort study with a very long follow-up, we studied whether pattern electroretinograms (PERG) amplitudes and blue-on-yellow visual evoked potential (BY-VEP) latencies can predict visual field defects. METHODS: Participants of the Erlangen Glaucoma Study were examined with PERG and BY-VEP between 9/1991 and 8/2001. Stimuli were created using an optical bench with Maxwellian view and consisted of vertical gratings (0,88 cpd) in a 32° field for both PERG and BY-VEP. Patients were treated according to clinical standards and performed standard automated perimetry (SAP) annually. Retrospectively, patients with normal SAP at baseline were selected. Primary endpoint was conversion to perimetric glaucoma. Predictive value was modeled using Kaplan-Meier analyses and a multivariate cox proportional hazards model with the continuous variables PERG amplitude, BY-VEP peak time and SAP square-root of loss variance (sLV) after stratification for Jonas classification of the optic discs. RESULTS: Of 412 patients (288: Jonas 0, 103: I, and 21: II; baseline age: 20-60 years), 65 converted to perimetric glaucoma during follow-up (0.5-23.3 years; median 5.5 years). Optic disc classification was a strong risk factor for conversion (log rank p < 0.0001), and patients with more advanced changes progressed earlier. In the multivariate analysis (log rank p = 0.005), only PERG amplitude remained an independent risk factor after stratification for optic disc morphology (p = 0.021), with a ~ 30% higher risk per µV amplitude decrease. CONCLUSIONS: PERG helps to estimate glaucoma suspects' risk for visual field defects.


Asunto(s)
Glaucoma , Hipertensión Ocular , Humanos , Adulto Joven , Adulto , Persona de Mediana Edad , Pruebas del Campo Visual , Potenciales Evocados Visuales , Estudios Retrospectivos , Campos Visuales , Estudios de Seguimiento , Estudios Longitudinales , Presión Intraocular , Hipertensión Ocular/tratamiento farmacológico , Glaucoma/diagnóstico , Electrorretinografía , Trastornos de la Visión/diagnóstico
3.
Graefes Arch Clin Exp Ophthalmol ; 260(4): 1171-1181, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34821990

RESUMEN

BACKGROUND AND AIM: In the past, increased latencies of the blue-on-yellow pattern visually evoked potentials (BY-VEP), which predominantly originate in the koniocellular pathway, have proven to be a sensitive biomarker for early glaucoma. However, a complex experimental setup based on an optical bench was necessary to obtain these measurements because computer screens lack sufficient temporal, spatial, spectral, and luminance resolution. Here, we evaluated the diagnostic value of a novel setup based on a commercially available video projector. METHODS: BY-VEPs were recorded in 126 participants (42 healthy control participants, 12 patients with ocular hypertension, 17 with "preperimetric" glaucoma, and 55 with perimetric glaucoma). Stimuli were created with a video projector (DLP technology) by rear projection of a blue checkerboard pattern (460 nm) for 200 ms (onset) superimposed on a bright yellow background (574 nm), followed by an offset interval where only the background was active. Thus, predominantly S-cones were stimulated while L- and M-cone responses were suppressed by light adaptation. Times of stimulus onset to VEP onset-trough (N-peak time) and offset-peak (P-peak time) were analyzed after age-correction based on linear regression in the normal participants. RESULTS: The resulting BY-VEPs were quite similar to those obtained in the past with the optical bench: pattern-onset generated a negative deflection of the VEP, whereas the offset-response was dominated by a positive component. N-peak times were significantly increased in glaucoma patients (preperimetric 136.1 ± 10 ms, p < 0.05; perimetric 153.1 ± 17.8 ms, p < 0.001) compared with normal participants (123.6 ± 7.7 ms). Furthermore, they were significantly correlated with disease severity as determined by visual field losses retinal nerve fiber thinning (Spearman R = -0.7, p < 0.001). CONCLUSIONS: Video projectors can be used to create optical stimuli with high temporal and spatial resolution, thus potentially enabling sophisticated electrophysiological measurements in clinical practice. BY-VEPs based on such a projector had a high diagnostic value for detection of early glaucoma. Registration of study Registration site: www. CLINICALTRIALS: gov Trial registration number: NCT00494923.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Hipertensión Ocular , Potenciales Evocados Visuales , Glaucoma/diagnóstico , Glaucoma de Ángulo Abierto/diagnóstico , Humanos , Pruebas del Campo Visual
4.
Graefes Arch Clin Exp Ophthalmol ; 259(2): 483-494, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32960321

RESUMEN

PURPOSE: To measure parameters of the cardiac cycle-induced pulsatile light absorption signal (plethysmography signal) of the optic nerve head (ONH) and to compare parameters between normal subjects and patients with different stages of glaucoma. PATIENTS AND METHODS: A recently developed video ophthalmoscope was used to acquire short video sequences (10 s) of the ONH. After image registration and trend correction, the pulsatile changing light absorption at the ONH tissue (excluding large vessels) was calculated. The changing light absorption depends on the pulsatile changing blood volume. Various parameters, including peak amplitude, steepness, time-to-peak, full width at half maximum (FWHM), and pulse duration, were calculated for averaged individual pulses (heartbeats) of the plethysmography signal. This method was applied to 19 healthy control subjects and 91 subjects with ocular hypertension, as well as different stages of primary open-angle glaucoma (17 subjects with ocular hypertension, 24 with preperimetric glaucoma, and 50 with perimetric glaucoma). RESULTS: Compared to the normal subjects, significant reductions (p < 0.001) in peak amplitude and steepness were observed in the group of perimetric glaucoma patients, but no significant difference was found for time-to-peak, FWHM, and pulse duration. Peak amplitude and steepness showed high correlations with RNFL thickness (p < 0.001). CONCLUSIONS: The presented low-cost video-ophthalmoscope permits measurement of the plethysmographic signal of the ONH tissue and calculation of different blood flow-related parameters. The reduced values of the amplitude and steepness parameters in perimetric glaucoma patients suggest decreased ONH perfusion and blood volume. This outcome is in agreement with results from other studies using OCT angiography and laser speckle flowgraphy, which confirm reduced capillary density in these patients. Registration site: www.clinicaltrials.gov , Trial registration number: NCT00494923.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Disco Óptico , Glaucoma/diagnóstico , Humanos , Presión Intraocular , Pletismografía , Tomografía de Coherencia Óptica , Campos Visuales
5.
Graefes Arch Clin Exp Ophthalmol ; 254(2): 259-68, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26553198

RESUMEN

PURPOSE: To investigate whether a conventional, monitor-based multifocal visual evoked potential (mfVEP) system can be used to record steady-state mfVEP (ssmfVEP) in healthy subjects and to study the effects of temporal frequency, electrode configuration and alpha waves. METHODS: Multifocal pattern reversal VEP measurements were performed at 58 dartboard fields using VEP recording equipment. The responses were measured using m-sequences with four pattern reversals per m-step. Temporal frequencies were varied between 6 and 15 Hz. Recordings were obtained from nine normal subjects with a cross-shaped, four-electrode device (two additional channels were derived). Spectral analyses were performed on the responses at all locations. The signal to noise ratio (SNR) was computed for each response using the signal amplitude at the reversal frequency and the noise at the neighbouring frequencies. RESULTS: Most responses in the ssmfVEP were significantly above noise. The SNR was largest for an 8.6-Hz reversal frequency. The individual alpha electroencephalogram (EEG) did not strongly influence the results. The percentage of the records in which each of the 6 channels had the largest SNR was between 10.0 and 25.2 %. CONCLUSION: Our results in normal subjects indicate that reliable mfVEP responses can be achieved by steady-state stimulation using a conventional dartboard stimulator and multi-channel electrode device. The ssmfVEP may be useful for objective visual field assessment as spectrum analysis can be used for automated evaluation of responses. The optimal reversal frequency is 8.6 Hz. Alpha waves have only a minor influence on the analysis. Future studies must include comparisons with conventional mfVEP and psychophysical visual field tests.


Asunto(s)
Potenciales Evocados Visuales/fisiología , Campos Visuales/fisiología , Adulto , Corteza Cerebral/fisiología , Electroencefalografía , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Relación Señal-Ruido , Vías Visuales/fisiología , Adulto Joven
6.
Graefes Arch Clin Exp Ophthalmol ; 254(5): 937-46, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26883356

RESUMEN

PURPOSE: To compare perimetric data based on the second-generation frequency doubling technology (FDT) and on flicker defined form (FDF) stimulation in early glaucoma patients. METHODS: Seventy-two experienced glaucoma patients and 50 healthy subjects of the Erlangen Glaucoma Registry participated in the study. The definition of glaucoma was solely based on optic disc appearance. All patients underwent FDF perimetry (HEP), FDT perimetry (Matrix), standard automated perimetry (SAP, Octopus), and peripapillar measurements of the RNFL thickness (Spectralis OCT). Exclusion criteria were: mean defect (MD) in SAP > 6 dB, eye diseases other than glaucoma, or non-reliable FDF or FDT measurements. Statistical analyses included comparison of the standard indices and correlations between methods. Venn-diagrams show the number of patients with abnormal results in HEP, Matrix, SAP, and mean RNFL thickness. RESULTS: Mean defect data from FDT and FDF perimetry were strongly correlated (R = -0.85, P <0.001). In this cohort of early glaucoma patients, the MD values were 6.1 ± 5.0 dB (FDF) and 4.5 ± 4.1 dB (FDT). Sensitivity in this patient group was 65 % for FDF-MD, 60 % for FDT-MD, and 60 % for RNFL-thickness, all at a specificity of 95 %. The correlation analysis between local RNFL thickness and corresponding visual defects revealed significant Spearman correlation coefficients for the arcuate bundles of the visual field (FDF-inferior: R = -0.65, FDF-superior: R = -0.74, FDT-inferior: R = -0.55, FDT-superior: R = -0.72). CONCLUSION: FDF and FDT stimulations can be used to detect patients with early glaucoma. Combined consideration of RNFL thickness and results from one of these perimetric tests can increase the total number of detected patients.


Asunto(s)
Glaucoma de Ángulo Abierto/diagnóstico , Glaucoma de Baja Tensión/diagnóstico , Trastornos de la Visión/diagnóstico , Pruebas del Campo Visual/métodos , Campos Visuales , Adulto , Anciano , Estudios de Cohortes , Diagnóstico Precoz , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fibras Nerviosas/patología , Células Ganglionares de la Retina/patología , Tomografía de Coherencia Óptica
7.
Graefes Arch Clin Exp Ophthalmol ; 253(1): 107-14, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25308782

RESUMEN

PURPOSE: Higher levels of short-term fluctuation of intraocular pressure (IOP) are characteristic of pseudoexfoliation syndrome (PEX). However, it is not known whether they are just a side effect of the higher mean intraocular pressure (IOP) or an independent feature. The purpose of this study was to compare short-term fluctuation of IOP between eyes with PEX and control eyes that were matched as closely as possible for mean IOP. METHODS: In this retrospective case-control study, all patients with confirmed PEX were identified from the database of the Erlangen Glaucoma Registry. From the same database, matched control eyes with similar treatment, age, glaucoma stage, and mean IOP were identified. For each patient, data from multiple extended diurnal IOP profiles were available. RESULTS: Seventy-eight eyes were included in the study (39 with PEX and 39 matched control eyes). Although a very close match was achieved, a small but statistically significant difference in mean IOP was still present, but this did not seem to explain the differences in IOP fluctuation levels. Eyes with PEX had significantly higher short-term IOP fluctuations (SD of IOP and range of IOP). CONCLUSIONS: The higher levels of short-term fluctuation in IOP appear to be an independent feature of PEX and not merely a secondary effect of the higher mean IOP. We suggest that this may have practical implications, even if IOP fluctuation levels should not prove to be an independent risk factor for development/progression of glaucoma, because more frequent measurements are needed in these patients to obtain good estimates of mean IOP and changes in IOP under treatment.


Asunto(s)
Síndrome de Exfoliación/fisiopatología , Glaucoma de Ángulo Abierto/fisiopatología , Presión Intraocular/fisiología , Hipertensión Ocular/fisiopatología , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tonometría Ocular , Pruebas del Campo Visual , Campos Visuales/fisiología
8.
Graefes Arch Clin Exp Ophthalmol ; 253(3): 447-55, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25511293

RESUMEN

PURPOSE: To assess the potential of flicker-defined form (FDF) perimetry to detect functional loss in patient groups with beginning glaucoma, and to evaluate the dynamic range of the FDF stimulus in individual patients and at individual test positions. METHODS: FDF perimetry and standard automated perimetry (SAP) were performed at identical test locations (adapted G1 protocol) in 60 healthy subjects and 111 glaucoma patients. All patients showed glaucomatous optic disc appearance. Grouping within the glaucoma cohort was based on SAP-performance: 33 "preperimetric" open-angle glaucoma (OAG) patients, 28 "borderline" OAG (focal defects and SAP-mean defect (MD) <2 dB), 33 "early" OAG (SAP-MD < 5 dB), 17 "advanced" OAG. All participants were experienced in psychophysical and perimetric tests. Defect values and the areas under receiver operating characteristic curves (ROC) in patient groups were statistically compared. RESULTS: The values of FDF-MD in the preperimetric, borderline, and early OAG group were 2.7 ± 3.4 dB, 5.5 ± 2.6 dB, and 8.5 ± 3.4 dB respectively (all significantly above normal). The percentage of patients exceeding normal FDF-MD was 27.3 %, 60.7 %, and 87.9 % respectively. The age-adjusted FDF-mean defect (MD) of the G1X-protocol was not significantly correlated with refractive error, lens opacity, pupil size, or gender. Occurrence of ceiling effects (inability to detect targets at highest contrast) showed a high correlation with visual field losses (R = 0.72, p < 0.001). Local analysis indicates that SAP losses exceeding 5 dB could not be distinguished with the FDF technique. CONCLUSION: The FDF stimulus was able to detect beginning glaucoma damage. Patients with SAP-MD values exceeding 5 dB should be monitored with conventional perimetry because of its larger dynamic range.


Asunto(s)
Glaucoma de Ángulo Abierto/diagnóstico , Enfermedades del Nervio Óptico/diagnóstico , Trastornos de la Visión/diagnóstico , Pruebas del Campo Visual/métodos , Campos Visuales/fisiología , Anciano , Femenino , Glaucoma de Ángulo Abierto/fisiopatología , Humanos , Presión Intraocular/fisiología , Masculino , Persona de Mediana Edad , Enfermedades del Nervio Óptico/fisiopatología , Tonometría Ocular , Trastornos de la Visión/fisiopatología , Agudeza Visual/fisiología
9.
BMC Ophthalmol ; 14: 122, 2014 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-25316067

RESUMEN

BACKGROUND: The diurnal fluctuation of intraocular pressure may be relevant in glaucoma. The aim of this study was to find out whether the timing of diurnal fluctuation is stable over the years. METHODS: Long-term IOP data from the Erlangen Glaucoma Registry, consisting of several annual extended diurnal IOP profiles for each patient, was retrospectively analyzed. Normal subjects, patients with ocular hypertension and with pigment dispersion syndrome were included because these subjects had not been treated with antiglaucomatous medications at the time of data acquisition. A cosine curve was fitted to the IOP data and the stability of individual rhythms over the years was tested using the Rayleigh test. To compare the peak times among groups, means were calculated only from subjects with a significant Rayleigh test. RESULTS: Of the fifty-two eligible subjects, a total of 364 extended diurnal IOP profiles measured in a sitting position had been collected over a period of 114 ± 39 months. The Rayleigh test indicated intraindividual stability of phase timing only in 19 subjects (36%). In subjects with pigment dispersions syndrome, peak IOP occurred on average two hours and seven minutes later during the day compared with subjects without this condition (p = 0.05). CONCLUSIONS: Fitting of cosine curves to the clinical IOP profiles was generally feasible, although careful interpretation is warranted due to lack of measurements in supine position and between midnight and 7 am. The interesting observation of a phase lag in eyes with pigment dispersion syndrome warrants confirmation and exploration in future prospective studies. The analysis of the IOP data showed no stable individual rhythm in the long term in a majority of patients.


Asunto(s)
Ritmo Circadiano/fisiología , Glaucoma de Ángulo Abierto/fisiopatología , Presión Intraocular/fisiología , Hipertensión Ocular/fisiopatología , Adulto , Anciano , Femenino , Voluntarios Sanos , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Postura , Estudios Retrospectivos , Tonometría Ocular
10.
J Vis ; 14(9)2014 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-25122214

RESUMEN

The aim of this work was to investigate the mechanisms of lateral interactions involved in flicker perception. Furthermore, the spatial properties of the monoptic and dichoptic components of these mechanisms were studied. We quantified the perceived flicker strength (PFS) in the center of a test stimulus, which was simultaneously modulated with a surround stimulus of variable size. The modulation depth of a separate stimulus, identical to the center test stimulus but without the surround, was determined using a two-alternative forced choice procedure. Using LCD goggles synchronized to the frame rate of a CRT screen, the center and surround of the test stimulus were presented either monoptically or dichoptically. In the monoptic condition, center-surround interactions have subcortical and cortical origins. In the dichoptic condition, center-surround interactions must have a cortical origin. The difference between the dichoptic and the monoptic data is an estimate of the contribution of the subcortical mechanisms. At each condition (surround stimulus size; monoptic or dichoptic presentation), the PFS was measured for phase differences between center and surround stimuli. The PFS changed systematically with phase difference. It also was observed that the PFS in the center stimulus changed merely be the presence of a surround stimulus independently of the center-surround phase difference. We propose that this is a phase-independent mechanism related to contrast adaptation owing to the presence of surround modulation. Our data suggest that both phase-dependent and -independent mechanisms have cortical and subcortical origins. There were no systematic differences between the spatial properties of subcortical and cortical components involved in PFS modulation.


Asunto(s)
Sensibilidad de Contraste/fisiología , Corteza Visual/fisiología , Vías Visuales/fisiología , Percepción Visual/fisiología , Adulto , Área de Dependencia-Independencia , Humanos , Persona de Mediana Edad , Retina/fisiología , Células Ganglionares de la Retina/fisiología , Adulto Joven
11.
PLoS One ; 18(5): e0284743, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37146019

RESUMEN

The paper presents a comparative study of the pulsatile attenuation amplitude (PAA) within the optic nerve head (ONH) at four different areas calculated from retinal video sequences and its relevance to the retinal nerve fiber layer thickness (RNFL) changes in normal subjects and patients with different stages of glaucoma. The proposed methodology utilizes processing of retinal video sequences acquired by a novel video ophthalmoscope. The PAA parameter measures the amplitude of heartbeat-modulated light attenuation in retinal tissue. Correlation analysis between PAA and RNFL is performed in vessel-free locations of the peripapillary region with the proposed evaluating patterns: 360° circular area, temporal semi-circle, nasal semi-circle. For comparison, the full ONH area is also included. Various positions and sizes of evaluating patterns in peripapillary region were tested which resulted in different outputs of correlation analysis. The results show significant correlation between PAA and RNFL thickness calculated in proposed areas. The highest correlation coefficient Rtemp = 0.557 (p<0.001) reflects the highest PAA-RNFL correspondence in the temporal semi-circular area, compared to the lowest value in the nasal semi-circular area (Rnasal = 0.332, p<0.001). Furthermore, the results indicate the most relevant approach to calculate PAA from the acquired video sequences is using a thin annulus near the ONH center. Finally, the paper shows the proposed photoplethysmographic principle based on innovative video ophthalmoscope can be used to analyze changes in retinal perfusion in peripapillary area and can be potentially used to assess progression of the RNFL deterioration.


Asunto(s)
Glaucoma , Disco Óptico , Humanos , Fibras Nerviosas , Células Ganglionares de la Retina , Glaucoma/diagnóstico , Tomografía de Coherencia Óptica/métodos
12.
J Glaucoma ; 32(3): 186-194, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36730078

RESUMEN

PRCIS: COVID-19 underlines the importance of telemedical diagnostics. The smartphone-based campimetry (Sb-C) is a newly developed digital application allowing visual field testing using a head-mounted device and a smartphone. It enables visual field screening remotely from a clinic. BACKGROUND: Sb-C is a newly developed tool for functional ophthalmic diagnosis. This study aimed to examine the comparability of the Sb-C and Octopus 900 to ensure ophthalmological care in times of social distancing. METHODS: Total 93 eyes were included in the study. After an ophthalmological examination, the visual field was tested by the Octopus program G1 and by the smartphone-based campimeter. The Sb-C was performed using VR glasses and an iPhone 6. The software Sb-C was downloaded and installed as SmartCampiTracker app and is examining the 30-degree visual field with 59 test positions corresponding to the G pattern of Octopus G1. Sensitivities were recorded and saved on the app. In addition, test-retest reliability was tested on 6 ophthalmologically healthy participants. RESULTS: The group comprised 48 women and 45 men (mean age: 62.52±12.2 y) including 19 controls, 17 patients with ocular hypertension, 11 preperimetric glaucomas, and 46 perimetric glaucomas. The mean sensitivity (MS) of all points of G1 perimetry was 23.13 dB (95% CI, 22.08-24.18). The MS of the Sb-C was 21.23 dB (95% CI, 20.37-22.08). The correlation between the mean MS measured by G1 perimetry and the Sb-C was strong ( r =0.815, P <0.05). The test-retest reliability showed a correlation of r =0.591 ( P <0.05) . CONCLUSIONS: With some technical adjustments, the Sb-C shows promise for screening glaucoma and monitoring disease progression remotely from an ophthalmologic clinic.


Asunto(s)
COVID-19 , Glaucoma , Masculino , Humanos , Femenino , Persona de Mediana Edad , Anciano , Campos Visuales , Teléfono Inteligente , Reproducibilidad de los Resultados , Presión Intraocular , Glaucoma/diagnóstico , Pruebas del Campo Visual
13.
Doc Ophthalmol ; 124(2): 79-90, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22227776

RESUMEN

Flash electroretinogram responses were measured in normal subjects to different chromatic combinations of flashes and backgrounds. The amplitudes of the flash response components were measured at different flash strengths and could be described by a generalized Naka-Rushton function. The measurements were repeated at different background luminances to study adaptation effects. It was found that when flash strength and background luminance were expressed in photometric terms (cd s/m² and cd/m², respectively), then the responses were very similar for all chromatic combinations with the exception of the condition in which blue (peak wavelength 458 nm) was flashed upon an orange (peak wavelength 591 nm) background. We propose that in this condition, a second (possibly S-cone or rod-driven) mechanism intrudes. The negative response after the b-wave (here called "photopic negative response" or PhNR for all conditions) is thought to reflect ganglion cell activity and was also largest at this condition. Responses were measured to the 458 nm flash on 591 nm background and the reversed combination in a population of 39 normal subjects and 49 glaucoma patients. It was found that the PhNR amplitude was affected by glaucoma in all conditions. Other component parameters, reflecting responses and adaptation dynamics, were not altered. The best stimulus condition among the conditions used to separate the PhNR amplitude of normals and patients was a 1 cd s/m² 458 nm flash on a 10 cd/m² 591 nm background.


Asunto(s)
Electrorretinografía/métodos , Glaucoma/fisiopatología , Células Fotorreceptoras Retinianas Conos/fisiología , Células Fotorreceptoras Retinianas Bastones/fisiología , Adulto , Visión de Colores , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estimulación Luminosa
14.
Doc Ophthalmol ; 124(3): 237-48, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22457046

RESUMEN

The aim of this study is to measure the on- and off-responses and their response asymmetries elicited by sawtooth stimuli in normal subjects and glaucoma patients. Furthermore, the correlation between the ERGs and other functional and structural parameters are investigated. Full-field stimuli were produced using a Ganzfeld bowl with Light Emitting Diodes (LEDs) as light sources. On- and off-response ERGs were recorded from 17 healthy subjects, 12 pre-perimetric and 15 perimetric glaucoma patients using 4-Hz luminance rapid-on and rapid-off sawtooth stimuli (white light; mean luminance 55 cd/m(2)) at 100% contrast. The on- and off-responses were added to study response asymmetries. In addition, flash ERGs were elicited by red stimuli (200 cd/m(2)) on a blue background (10 cd/m(2)). The mean deviations (MD) of the visual field defects were obtained by standard automated perimetry. The retinal nerve fibre layer thickness (RNFLT) was measured with Spectral Domain Optical Coherence Tomography (SOCT). We studied the correlation between ERG response amplitudes, visual field mean deviation (MDs) and RNFLT values. The on-responses showed an initial negative (N-on) followed by a positive (P-on), a late positive (LP-on) and a late negative responses (LN-on). The off-responses showed an initial positive (P-off) a late positive (LP-off) and a late negative response (LN-off). The addition of on- and off-responses revealed an initial positive (P-add) and a late negative response (LN-add). The on-response components (N-on, P-on and LN-on) in the glaucoma patients were relatively similar to those of the control subjects. However, the LP-on was significantly elevated (p = 0.03) in perimetric patients. The LP-off was significantly elevated (p < 0.001), and the amplitude of LN-off was significantly reduced in perimetric patients (p = 0.02). The LN-add amplitude was significantly reduced (p < 0.001) and delayed (p = 0.03) in perimetric patients. The amplitudes of the LN-off and LN-add ERG components were significantly correlated with the PhNR in the flash ERG (LN-off: p = 0.01; LN-add: p < 0.001) and with RNFLT (LN-off: p = 0.006; LN-add: p = 0.001). On- and off-response ERGs and their response asymmetries, elicited by sawtooth stimuli, are altered in the glaucoma patients. The late components are affected. Changes in the late negative components are correlated with structural and other functional changes.


Asunto(s)
Electrorretinografía , Glaucoma de Ángulo Abierto/fisiopatología , Enfermedades del Nervio Óptico/fisiopatología , Retina/fisiología , Anciano , Femenino , Humanos , Presión Intraocular/fisiología , Masculino , Persona de Mediana Edad , Fibras Nerviosas/patología , Estimulación Luminosa , Tomografía de Coherencia Óptica , Pruebas del Campo Visual , Campos Visuales
15.
Doc Ophthalmol ; 122(1): 53-62, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21267627

RESUMEN

Recent studies suggest a diagnostic value of the photopic negative response (PhNR) with a long-duration stimulus. The aim of this study was to record the on and off responses of the photopic fullfield electroretinogram (ERG) in normal subjects and glaucoma patients. We focused on different waves of the responses after onset and offset of the long-duration stimulus ERG. Photopic fullfield ERGs were recorded in response to a white bright LED flash on a white 20 cd/m(2) background. Stimulus luminances were 40, 60 and 80 cd/m(2). Responses were averaged using a flash duration of 240 ms and an offset period of 500 ms. We examined 19 healthy subjects, 27 patients with glaucomatous optic disc atrophy and 7 ocular hypertensive patients. The amplitudes and implicit times of the on and off responses of the human ERG depended on flash luminance. Comparing patients with glaucoma and healthy subjects for the 60 cd/m² flash, there was a significant change in the PhNRs (at onset: P < 0.01, at offset: P < 0.001) of the d-wave and of the i-wave at offset (P < 0.01). No significant difference was found for peak times of the fullfield ERG and for a- and b-wave amplitudes. PhNR amplitudes were significantly correlated with mean thickness of retinal nerve fibre layer as measured with OCT. In comparison with the normal photopic long-flash ERG, glaucoma patients showed changes in the PhNR amplitude following stimulus onset and in waves following stimulus offset.


Asunto(s)
Visión de Colores , Electrorretinografía/métodos , Glaucoma/diagnóstico , Glaucoma/fisiopatología , Anciano , Atrofia , Estudios de Cohortes , Femenino , Glaucoma/patología , Humanos , Masculino , Persona de Mediana Edad , Hipertensión Ocular/diagnóstico , Hipertensión Ocular/patología , Hipertensión Ocular/fisiopatología , Disco Óptico/patología , Estimulación Luminosa/métodos , Retina/patología
16.
Invest Ophthalmol Vis Sci ; 62(6): 17, 2021 05 03.
Artículo en Inglés | MEDLINE | ID: mdl-33988692

RESUMEN

Purpose: The purpose of this study was to characterize summation of temporal L- and M-cone contrasts in the parvo- (P-) and magnocellular (M-) pathways in glaucoma and the relationship between the respective temporal contrast sensitivities (tCS) and clinical parameters. Methods: Perifoveal tCS to isolated or combined L- and M-cone contrasts (with different contrast ratios, and therefore different luminance and chromatic components) were measured at different temporal frequencies (at 1 or 2 Hz and at 20 Hz) using triple silent substitution in 73 subjects (13 healthy, 25 with glaucoma, and 35 with perimetric glaucoma). A vector summation model was used to analyze whether perception was driven by the P-pathway, the M-pathway, or both. Using this model, L- and M-cone input strengths (AL, AM) and phase differences between L- and M-cone inputs were estimated. Results: Perception was always mediated by the P-pathway at low frequencies, as indicated by a median phase angle of 179.84 degrees (cone opponency) and a median AL/AM ratio of 1.04 (balanced L- and M-cone input strengths). In contrast, perception was exclusively mediated by the M-pathway at higher frequencies (input strength not balanced: AL/AM = 2.94, median phase angles = 130.17 degrees). Differences in phase were not significant between diagnosis groups (Kruskal-Wallis = 0.092 for P- and 0.35 for M-pathway). We found differences between groups only for the M-pathway (L-cone tCS deviations at 20 Hz were significantly lower in the patients with glaucoma P = 0.014, with a strong tendency in M-cones P = 0.049). L-cone driven tCS deviations at 20 Hz were linearly correlated with perimetric mean defect (MD) and quadratically correlated with retinal nerve fiber layer (RNFL) thickness. Conclusions: Unaltered phase angles between L- and M-cone inputs in glaucoma indicated intact temporal processing. Only in the M-pathway, contrast sensitivity deviations were closely related to diagnosis group, MD, and RNFL thickness, indicating M-pathway involvement.


Asunto(s)
Opsinas de los Conos/fisiología , Sensibilidad de Contraste/fisiología , Cuerpos Geniculados/fisiología , Glaucoma de Ángulo Abierto/fisiopatología , Células Fotorreceptoras Retinianas Conos/fisiología , Células Ganglionares de la Retina/fisiología , Adulto , Anciano , Femenino , Humanos , Presión Intraocular/fisiología , Masculino , Persona de Mediana Edad , Tomografía de Coherencia Óptica , Pruebas del Campo Visual , Campos Visuales/fisiología , Vías Visuales/fisiología
17.
Invest Ophthalmol Vis Sci ; 62(9): 14, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-34241626

RESUMEN

Purpose: To compare the electroretinographical (ERG) responses elicited by L- and M-cone isolating ON- and OFF-sawtooth stimuli in normal subjects and glaucoma patients. Methods: Twenty-one normal subjects and 44 primary open-angle glaucoma patients participated in the study. L- and M-cone isolating (18% cone contrast; 284 cd/m2) rapid ON- and rapid OFF-sawtooth (4 Hz) stimuli with two stimulus sizes (full-field (FF) and central 70° diameter) were generated using the triple silent substitution technique. ON- and OFF-response asymmetries were studied by adding the two (to obtain L-add and M-add responses). The initial positive (P) and subsequent late negative (LN) components of the L-add and M-add ERGs were compared between the subject groups and correlated with retinal nerve fiber layer thickness (RNFLT) and pattern ERG responses. Results: The responses to L-ON and to M-OFF stimuli and vice versa resembled each other particularly with 70° stimuli. The PL-add amplitudes were not significantly different between the normal subjects and glaucoma patients, whereas the LNL-add amplitude was significantly (P < 0.01) smaller in the glaucoma patients. Both PM-add and LNM-add were not significantly different between the subject groups. The PERG amplitude with 0.8° check sizes and the 0.8°/16° amplitude ratio (PERG ratio) were significantly (P < 0.05) different between the subject groups. The 70° LNL-add amplitude and the 0.8° PERG amplitude were significantly correlated with RNFLT. Conclusions: The ERGs to 70° cone isolating sawtooth stimuli reflect cone opponency. The cone opponent ERG responses were not significantly different between glaucoma patients and normal subjects. Luminance driven L-add responses were significantly different, indicating that central luminance signals are mainly affected in glaucoma.


Asunto(s)
Electrorretinografía/métodos , Glaucoma de Ángulo Abierto/fisiopatología , Retina/fisiopatología , Células Fotorreceptoras Retinianas Conos/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Glaucoma de Ángulo Abierto/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Estimulación Luminosa/métodos
18.
PLoS One ; 16(5): e0249202, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33961631

RESUMEN

PURPOSE: Agonistic ß2-adrenergic receptor autoantibodies (ß2-agAAb) have been observed in sera of patients with ocular hypertension and open-angle glaucoma (OAG). They target the ß2-receptors on trabecular meshwork, ciliary body and pericytes (Junemann et al. 2018; Hohberger et al. 2019). In addition to their influence on the intraocular pressure, an association to retinal microcirculation is discussed. This study aimed to investigate foveal avascular zone (FAZ) characteristics by en face OCT angiography (OCT-A) in glaucoma suspects and its relationship to ß2-agAAb status in patients with OAG. MATERIAL AND METHODS: Thirty-four patients (28 OAG, 6 glaucoma suspects) underwent standardized, clinical examination including sensory testing as white-on-white perimetry (Octopus G1, mean defect, MD) and structural measures as retinal nerve fibre layer (RNFL) thickness, neuroretinal rim width (BMO-MRW), retinal ganglion cell layer (RGCL) thickness, and inner nuclear layer (INL) thickness with high-resolution OCT. FAZ characteristics were measured by OCT-A scans of superficial vascular plexus (SVP), intermediate capillary plexus (ICP), and deep capillary plexus (DCP). FAZ-R was calculated (area FAZ (SVP)/area FAZ (ICP)). Using cardiomyocyte bioassays we analysed serum samples for the presence of ß2-agAAb. RESULTS: (I) Total mean FAZ area [mm2]: 0.34±0.16 (SVP), 0.24±0.12 (ICP), and 0.49±0.24 (DCP); mean FAZ-R 1.58±0.94. No correlation was seen for FAZ-R with MD, RNFL, BMO-MRW, RGCL thickness and INL thickness (p>0.05). (II) ß2-agAAb have been observed in 91% patients and showed no correlation with MD, RNFL, BMO-MRW, RGCL thickness and INL thickness (p>0.05). (III) FAZ-R correlated significantly with the ß2-agAAb-induced increase of the beat rate of cardiomyocyte (p = 0.028). CONCLUSION: FAZ characteristics did not correlate with any glaucoma associated functional and morphometric follow-up parameter in the present cohort. However, level of ß2-agAAb showed a significantly correlation with FAZ-ratio. We conclude that ß2-agAAb might be a novel biomarker in glaucoma pathogenesis showing association to FAZ-ratio with OCT-A.


Asunto(s)
Autoanticuerpos/inmunología , Glaucoma de Ángulo Abierto/fisiopatología , Microcirculación/inmunología , Receptores Adrenérgicos beta 2/inmunología , Anciano , Femenino , Glaucoma de Ángulo Abierto/inmunología , Glaucoma de Ángulo Abierto/patología , Humanos , Presión Intraocular , Masculino , Células Ganglionares de la Retina/patología
19.
Vis Neurosci ; 27(3-4): 79-90, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20796325

RESUMEN

Full-field electroretinograms were recorded from five normal human subjects using white light (mean luminance: 250 cd/m2) sine wave stimuli at different frequencies and contrasts. In agreement with previous studies, we found that the amplitude of the fundamental component displayed a dip at about 12 Hz, coinciding with a maximum in the second harmonic component, indicating frequency doubling of the responses. By including measurements at different contrasts, we were able to recognize two (sine-like and transient) response components. We found that the waveform of the transient response was relatively frequency independent. An algorithm to separate the two components was developed. The interaction between these two components can explain the frequency-doubled responses around 12 Hz. The sine-like component is more linear and prominent in the low-frequency region, whereas the transient seems to be more nonlinear and prominent in the high-frequency region.


Asunto(s)
Sensibilidad de Contraste/fisiología , Electrorretinografía/métodos , Potenciales Evocados Visuales/fisiología , Psicofísica , Retina/fisiología , Adulto , Femenino , Análisis de Fourier , Humanos , Masculino , Persona de Mediana Edad , Estimulación Luminosa/métodos , Análisis de Componente Principal , Factores de Tiempo
20.
Ophthalmology ; 116(9): 1630-7, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19643487

RESUMEN

PURPOSE: Pathologic corneal neovascularization not only reduces corneal transparency and visual acuity, but also is one of the most significant preoperative and postoperative risk factors for graft rejection after corneal transplantation. The aim of this study was to test tolerability and efficacy of gene signal (GS)-101 eye drops, an antisense oligonucleotide against insulin receptor substrate-1, versus placebo on inhibition of progressive corneal neovascularization. DESIGN: Randomized, double-blind, multicenter, phase II clinical study. PARTICIPANTS AND CONTROLS: Interim analysis on 40 patients with progressive corneal neovascularization resulting from various underlying diseases being nonresponsive to conventional therapy. INTERVENTIONS: Four groups of 10 patients were treated for 3 months in this dose-finding study comparing 3 doses of GS-101 (eye drops twice daily; 43, 86, and 172 microg/day total) with placebo (10 patients per group). MAIN OUTCOME MEASURES: The primary end point was the area covered by pathologic corneal blood vessels, which was measured morphometrically on digitized slit-lamp pictures using image analysis techniques. RESULTS: GS-101 eye drops were well tolerated. All serious and 95% of all other adverse events were categorized by the investigators as unrelated. In 3 patients, there was a potentially related side effect of ocular surface discomfort. At a dose of 86 microg/day (43 microg/drop), GS-101 eye drops produced a significant inhibition and regression of corneal neovascularization (-2.04+/-1.57% of total corneal area; P = 0.0047), whereas the low dose tended to stabilize it (0.07+/-2.94%; P = 0.2088) compared with placebo (0.89+/-2.15%), where corneal neovascularization progressed in all patients. There was no apparent benefit to the higher dose (1.60+/-7.63%). CONCLUSIONS: The interim results of this phase II study suggest that GS-101 eye drops at an optimal dose of 86 microg/day are an effective and noninvasive approach specifically to inhibit and regress active corneal angiogenesis, a major risk factor for corneal graft transplantation and graft rejection. Safety concerns were not detected. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.


Asunto(s)
Inhibidores de la Angiogénesis/administración & dosificación , Neovascularización de la Córnea/tratamiento farmacológico , Oligonucleótidos/administración & dosificación , Adulto , Anciano , Anciano de 80 o más Años , Inhibidores de la Angiogénesis/efectos adversos , Neovascularización de la Córnea/patología , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Oligonucleótidos/efectos adversos , Soluciones Oftálmicas/administración & dosificación , Soluciones Oftálmicas/efectos adversos , Resultado del Tratamiento , Agudeza Visual/efectos de los fármacos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA