Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Arch Orthop Trauma Surg ; 139(1): 121-126, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30415415

RESUMEN

INTRODUCTION: The minimally invasive direct anterior approach (DAA) is an established approach for primary total hip arthroplasty (THA). The complication rates in hip revision arthroplasty are much higher in comparison with primary THA. A right positioning of the implants and a soft tissue, especially the abductors spearing approach, is important to get good functional results and low complication rates. The aim of this study was to show the clinical and radiological outcome of isolated revision hip arthroplasty of the cup by using the DAA. MATERIALS AND METHODS: Aseptic cup revisions were carried out in 48 patients using the DAA. A decision to exchange the stem was made intraoperatively in seven cases. Complications, radiological and functional outcome were assessed. All of the data were collected retrospectively. The mean follow-up period was 65 months. RESULTS: In most of the cases the standard DAA was used. A proximal extension was nescessary in 15 patients (31%). The mean cup inclination angle after revision was 44° (min. 25°, max. 62°). Six implants (12.5%) were located outside of the Lewinnek safe zone. The centers of rotation of the revision implants were a mean of 0.6 cm superior (min. 0, max. 2.2 cm) and 0.5 cm lateral (min. 0.2 cm, max 1.2 cm) in comparison with the center of rotation in the healthy hip on the contralateral side. Harris Hip Score improved significantly from 50 to 91 (P = 0.03). Complications noted consisted of two periprosthetic infections (4.2%), one aseptic cup loosening (2.1%), two hematomas requiring revision (4.2%), and one case each of femoral nerve injury, lower-leg venous thrombosis, and pneumonia. No dislocations were observed and there were no cases of heterotopic ossification based on the Brooker classification. No persistent damage of the nervus cutaneus femoris lateralis was found at the follow-up examinations. CONCLUSIONS: The DAA represents a feasible option in hip revision arthroplasty. Anatomic reconstruction of the cup is reproducibly possible. Good medium-term results can also be achieved. Particularly in relation to dislocation, the complication rates are low. Due to the learning curve, the DAA should only be used in hip revision arthroplasty by those with sufficient experience in primary THA. Adequate data regarding stem revisions through the DAA are not available at the moment.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Reoperación , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Artroplastia de Reemplazo de Cadera/estadística & datos numéricos , Estudios de Seguimiento , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Prótesis de Cadera , Humanos , Complicaciones Posoperatorias , Radiografía , Reoperación/efectos adversos , Reoperación/métodos , Reoperación/estadística & datos numéricos , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA