Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-39225035

RESUMEN

PURPOSE: To assess the visual impact of Diffusion Optics Technology™ 0.2 DOT lenses (SightGlass Vision Inc.) designed for myopia control on primary gaze. DOT spectacle lenses contain light scattering elements that scatter light as it passes through the lens which, in turn, reduces retinal image contrast. METHODS: Fifty-one children (12.2 ± 1.3, range 10-14 years; 51% females) were randomly assigned to wear DOT spectacle (n = 27) or single vision lenses (n = 24) across six investigational sites in North America. Binocular high- and low-contrast distant visual acuities, near visual acuity, reading speed, contrast sensitivity, stereoacuity and glare were assessed in primary gaze after at least 3 years of wear, with the study 95% powered in all metrics to detect significant differences between the groups. RESULTS: Mean binocular distance high-contrast (-0.09 ± 0.02 vs. -0.08 ± 0.02 logMAR, p = 0.81), low-contrast (0.05 ± 0.02 vs. 0.07 ± 0.02 logMAR, p = 0.52) and near visual acuity with glare sources (-0.06 ± 0.03 vs. -0.09 ± 0.03 logMAR, p = 0.32) were similar for DOT and single vision lens wearers, respectively. Contrast sensitivity was similar between children wearing DOT or single vision lenses across 11 of the 16 spatial frequencies (p > 0.05). Mean stereopsis was similar (p = 0.30) with the DOT lenses (33.2 ± 12.5″) and single vision lenses (38.1 ± 14.2″). Functional reading speed metrics were similar in both study groups, as was the objectively measured head tilt during reading (p > 0.05). The mean halo radius was 0.56° ± 0.17° with the DOT lenses compared with 0.50° ± 0.12° with single vision lenses (p = 0.02), but the statistically significant difference was smaller than the non-inferiority bound of 0.4°. CONCLUSION: Diffusion optics technology lenses provide a clinically equivalent visual experience to a standard single vision lens.

2.
Optom Vis Sci ; 99(3): 204-212, 2022 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-35086120

RESUMEN

SIGNIFICANCE: Treatment of myopic children with a dual-focus soft contact lens (DFCL; MiSight 1 day) produced sustained slowing of myopia progression over a 6-year period. Significant slowing was also observed in children switched from a single vision control to treatment lenses (3 years in each lens). PURPOSE: This study aimed to evaluate the effectiveness of DFCLs in sustaining slowed progression of juvenile-onset myopia over a 6-year treatment period and assess myopia progression in children who were switched to a DFCL at the end of year 3. METHODS: Part 1 was a 3-year clinical trial comparing DFCLs with a control contact lens (Proclear 1 day) at four investigational sites. In part 2, subjects completing part 1 were invited to continue for 3 additional years during which all children were treated with MiSight 1 day DFCLs (52 and 56 from the initially treated [T6] and control [T3] groups, respectively). Eighty-five subjects (45 [T3] and 40 [T6]) completed part 2. Cyclopleged spherical equivalent refractive errors (SEREs) and axial lengths (ALs) were monitored, and a linear mixed model was used to compare their adjusted change annually. RESULTS: Average ages at part 2 baseline were 13.2 ± 1.3 and 13.0 ± 1.5 years for the T6 and T3 groups, respectively. Slowed myopia progression in the T6 group observed during part 1 was sustained throughout part 2 (mean ± standard error of the mean: change from baseline SERE [in diopters], -0.52 ± 0.076 vs. -0.51 ± 0.076; change in AL [in millimeters], 0.28 ± 0.033 vs. 0.23 ± 0.033; both P > .05). Comparing progression rates in part 2 for the T6 and T3 groups, respectively, indicates that prior treatment does not influence efficacy (SERE, -0.51 ± 0.076 vs. -0.34 ± 0.077; AL, 0.23 ± 0.03 vs. 0.18 ± 0.03; both P > .05). Within-eye comparisons of AL growth revealed a 71% slowing for the T3 group (3 years older than part 1) and further revealed a small subset of eyes (10%) that did not respond to treatment. CONCLUSIONS: Dual-focus soft contact lenses continue to slow the progression of myopia in children over a 6-year period revealing an accumulation of treatment effect. Eye growth of the initial control cohort with DFCL was slowed by 71% over the subsequent 3-year treatment period.


Asunto(s)
Lentes de Contacto Hidrofílicos , Miopía , Longitud Axial del Ojo , Niño , Progresión de la Enfermedad , Humanos , Miopía/diagnóstico , Miopía/terapia , Refracción Ocular , Visión Ocular
3.
Evol Anthropol ; 29(5): 263-279, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32652819

RESUMEN

Mortuary behavior (activities concerning dead conspecifics) is one of many traits that were previously widely considered to have been uniquely human, but on which perspectives have changed markedly in recent years. Theoretical approaches to hominin mortuary activity and its evolution have undergone major revision, and advances in diverse archeological and paleoanthropological methods have brought new ways of identifying behaviors such as intentional burial. Despite these advances, debates concerning the nature of hominin mortuary activity, particularly among the Neanderthals, rely heavily on the rereading of old excavations as new finds are relatively rare, limiting the extent to which such debates can benefit from advances in the field. The recent discovery of in situ articulated Neanderthal remains at Shanidar Cave offers a rare opportunity to take full advantage of these methodological and theoretical developments to understand Neanderthal mortuary activity, making a review of these advances relevant and timely.


Asunto(s)
Entierro/historia , Hombre de Neandertal/fisiología , Paleontología , Animales , Cuevas , Fósiles , Fracturas Óseas/patología , Sedimentos Geológicos/química , Historia Antigua , Irak
4.
Rev Palaeobot Palynol ; 280: 104278, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32834132

RESUMEN

Pollen retention on clothes, footwear, hair and body has been used to link people to localities with distinctive vegetation, or soils containing distinctive palynomorphs. Little attention has been given to human skin as a possible medium for carrying a forensically important pollen load and whether this might survive attempts to remove it. We report here the results of experiments testing the retention of pollen of 10 flowering plant species on the human skin through repeated cycles of washing and drying hands, using the WHO protocol to standardize hand-washing and drying. Between 0.36% and 2.74% (mean 0.93%) of the initial pollen load was retained through a single hand-wash. Trace amounts of some species survived multiple hand-wash cycles. It is concluded that forensic analyses can be made of the pollen load of those parts of the skin that may have been in contact with palynologically distinctive vegetation, even in cases where the person involved has washed, or been washed. These observations may also be of relevance in cases where human skin became contaminated with other microscopic particulates.

5.
Eye Contact Lens ; 44 Suppl 1: S273-S282, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28617731

RESUMEN

PURPOSE: To determine the retention rate (RR) for neophyte patients fitted with contact lenses (CLs) and to identify factors associated with retention and dropout. METHOD: This multisite, sponsor-masked registry study evaluated the 1-year status of neophyte CL wearers fitted in a representative range of UK practices. A total of 26 UK investigational sites each recruited up to 89 neophyte patients. The participants were requested to complete surveys at 1 month (±1 week from date of fitting), 3 months (±2 weeks), and 12 months (±3 weeks) online or through phone. Participants were contacted by email (or phone) and invited to complete an online survey that asked a range of questions regarding their CL wearing experience. RESULTS: Of the 531 participants recruited, 65.3% (347/531) responded to at least one follow-up survey and 42.3% (225/531) responded to all three surveys. One in four patients showed discontinued CL wear by 12 months. Based on evaluable subjects at 12 months, the RR was 77.6% (194/250, 95% confidence interval: 72.0-82.3). The most common reason for discontinuation was problems with vision (41%), followed by discomfort (36%) and handling problems (25%). The factors affecting first-year RRs: sex, spherical refraction, lens usage (full time or part time), and supply method (collected or posted). CONCLUSIONS: In this prospective study, the first-year RR for neophyte CL wearers was 77.6%. This was consistent with that noted in a retrospective study: 74.0%. As with the previous study, the commonly cited reason for discontinuation was visual problems.


Asunto(s)
Lentes de Contacto/estadística & datos numéricos , Cooperación del Paciente/estadística & datos numéricos , Satisfacción del Paciente , Ajuste de Prótesis/estadística & datos numéricos , Agudeza Visual , Adolescente , Adulto , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Encuestas y Cuestionarios , Adulto Joven
6.
J Hum Evol ; 111: 102-118, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28874265

RESUMEN

The Neanderthal remains from Shanidar Cave, excavated between 1951 and 1960, have played a central role in debates concerning diverse aspects of Neanderthal morphology and behavior. In 2015 and 2016, renewed excavations at the site uncovered hominin remains from the immediate area where the partial skeleton of Shanidar 5 was found in 1960. Shanidar 5 was a robust adult male estimated to have been aged over 40 years at the time of death. Comparisons of photographs from the previous and recent excavations indicate that the old and new remains were directly adjacent to one another, while the disturbed arrangement and partial crushing of the new fossils is consistent with descriptions and photographs of the older discoveries. The newly discovered bones include fragments of several vertebrae, a left hamate, part of the proximal left femur, a heavily crushed partial pelvis, and the distal half of the right tibia and fibula and associated talus and navicular. All these elements were previously missing from Shanidar 5, and morphological and metric data are consistent with the new elements belonging to this individual. A newly discovered partial left pubic symphysis indicates an age at death of 40-50 years, also consistent with the age of Shanidar 5 estimated previously. Thus, the combined evidence strongly suggests that the new finds can be attributed to Shanidar 5. Ongoing analyses of associated samples, including for sediment morphology, palynology, and dating, will therefore offer new evidence as to how this individual was deposited in the cave and permit new analyses of the skeleton itself and broader discussion of Neanderthal morphology and variation.


Asunto(s)
Cuevas , Peroné , Fósiles , Hombre de Neandertal , Huesos Pélvicos , Animales , Hominidae , Humanos , Irak , Masculino
7.
J Hum Evol ; 105: 69-88, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28366201

RESUMEN

The paper presents the results of optical dating of potassium-rich feldspar grains obtained from the Haua Fteah cave in Cyrenaica, northeast Libya, focussing on the chronology of the Deep Sounding excavated by Charles McBurney in the 1950s and re-excavated recently. Samples were also collected from a 1.25 m-deep trench (Trench S) excavated during the present project below the basal level of the Deep Sounding. Optically stimulated luminescence (OSL) data sets for multi-grain, single aliquots of quartz for samples from the Middle Trench were previously published. Re-analyses of these OSL data confirm significant variation in the dose saturation levels of the quartz signal, but allow the most robust OSL ages to be determined for comparison with previous age estimates and with those obtained in this study for potassium-rich feldspars from the Deep Sounding. The latter indicate that humans may have started to visit the cave as early as ∼150 ka ago, but that major use of the cave occurred during MIS 5, with the accumulation of the Deep Sounding sediments. Correlations between optical ages and episodes of "Pre-Aurignacian" artefact discard indicate that human use of the cave during MIS 5 was highly intermittent. The earliest phases of human activity appear to have occurred during interstadial conditions (5e and 5c), with a later phase of lithic discard associated with more stadial conditions, possibly MIS 5b. We argue that the "Pre-Aurignacian" assemblage can probably be linked with modern humans, like the succeeding "Levalloiso-Mousterian" assemblage; two modern human mandibles associated with the latter are associated with a modelled age of 73-65 ka. If this attribution is correct, then the new chronology implies that modern humans using "Pre-Aurignacian" technologies were in Cyrenaica as early as modern humans equipped with "Aterian" technologies were in the Maghreb, raising new questions about variability among lithic technologies during the initial phases of modern human dispersals into North Africa.


Asunto(s)
Cuevas , Sedimentos Geológicos/análisis , Hominidae , Datación Radiométrica , Animales , Arqueología , Humanos , Libia , Mediciones Luminiscentes
8.
Optom Vis Sci ; 93(8): 836-47, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-27391535

RESUMEN

PURPOSE: To characterize and compare the prevalence of soft contact lens-related (SCL) dryness symptoms in large populations of SCL wearers in North America (NAm) and the United Kingdom (UK). METHODS: SCL wearers from NAm (n = 1443) and UK (n = 932) sites completed self-administered questionnaires on SCL symptoms and wearing experiences. A categorization for contact lens-related dry eye (CL-DE) was applied that combined Contact Lens Dry Eye Questionnaire (CLDEQ) items on dryness frequency and intensity at the end of the day (CL-DE+ = constantly/frequently/sometimes plus intensity = 3-5, and CL-DE- = never/rarely plus intensity = 0-1, Marginal = all other ratings). Data were analyzed across regions and categories, with p-values <0.05 significant. RESULTS: Compared to UK wearers, those in NAm wore fewer toric and multifocal designs, and reported significantly longer average and comfortable wearing times (p < 0.001) but similar levels of general and end-of-day comfort. The prevalence of CL-DE+ differed between the UK and NAm: CL-DE+: 31 vs. 39%, Marginal CL-DE: 13 vs. 14%, and CL-DE-: 56 vs. 47%, p = 0.0001. Although daily disposable (DD) lenses were worn more commonly in the UK than NAm (33 vs. 10%, p < 0.0001), their use did not impact the overall prevalence of dryness symptoms. Between regions, NAm wearers reported significantly more frequent and intense end-of-day discomfort and dryness (p < 0.0001) and were significantly more likely to use treatments for CL-related symptoms yet experienced a lower degree of relief. CONCLUSIONS: SCL wearers in NAm reported longer hours of wear with significantly more symptoms of dryness and discomfort. NAm wearers used dryness treatments more often, but experienced less relief than UK wearers. In both regions, the CL-DE categorization was useful to predict poorer comfort, shorter comfortable wearing time, and increased use of treatments. These results highlight the need to benchmark SCL performance locally or regionally to understand and focus on the challenges to the lens wearing experience.


Asunto(s)
Lentes de Contacto Hidrofílicos/efectos adversos , Síndromes de Ojo Seco/etiología , Adulto , Lentes de Contacto Hidrofílicos/estadística & datos numéricos , Equipos Desechables , Síndromes de Ojo Seco/diagnóstico , Síndromes de Ojo Seco/epidemiología , Femenino , Humanos , Masculino , América del Norte/epidemiología , Comodidad del Paciente , Prevalencia , Factores de Riesgo , Encuestas y Cuestionarios , Reino Unido/epidemiología
9.
Glob Chang Biol ; 20(1): 158-69, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23828718

RESUMEN

Our limited understanding of terrestrial ecosystem responses to elevated CO2 is a major constraint on predicting the impacts of climate change. A change in botanical composition has been identified as a key factor in the CO2 response with profound implications for ecosystem services such as plant production and soil carbon storage. In temperate grasslands, there is a strong consensus that elevated CO2 will result in a greater physiological stimulus to growth in legumes and to a lesser extent forbs, compared with C3 grasses, and the presumption this will lead in turn to a greater proportion of these functional groups in the plant community. However, this view is based on data mainly collected in experiments of three or less years in duration and not in experiments where defoliation has been by grazing animals. Grazing is, however, the most common management of grasslands and known in itself to influence botanical composition. In a long-term Free Air Carbon Dioxide Enrichment (FACE) experiment in a temperate grassland managed with grazing animals (sheep), we found the response to elevated CO2 in plant community composition in the first 5 years was consistent with the expectation of increased proportions of legumes and forbs. However, in the longer term, these differences diminished so that the proportions of grasses, legumes and forbs were the same under both ambient and elevated CO2 . Analysis of vegetation before and after each grazing event showed there was a sustained disproportionately greater removal ('apparent selection') of legumes and forbs by the grazing animals. This bias in removal was greater under elevated CO2 than ambient CO2 . This is consistent with sustained faster growth rates of legumes and forbs under elevated CO2 being countered by selective defoliation, and so leading to little difference in community composition.


Asunto(s)
Dióxido de Carbono , Fabaceae/crecimiento & desarrollo , Poaceae/crecimiento & desarrollo , Ovinos/fisiología , Animales , Ecosistema , Herbivoria , Nueva Zelanda
10.
J Hum Evol ; 66: 39-63, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24331954

RESUMEN

The 1950s excavations by Charles McBurney in the Haua Fteah, a large karstic cave on the coast of northeast Libya, revealed a deep sequence of human occupation. Most subsequent research on North African prehistory refers to his discoveries and interpretations, but the chronology of its archaeological and geological sequences has been based on very early age determinations. This paper reports on the initial results of a comprehensive multi-method dating program undertaken as part of new work at the site, involving radiocarbon dating of charcoal, land snails and marine shell, cryptotephra investigations, optically stimulated luminescence (OSL) dating of sediments, and electron spin resonance (ESR) dating of tooth enamel. The dating samples were collected from the newly exposed and cleaned faces of the upper 7.5 m of the ∼14.0 m-deep McBurney trench, which contain six of the seven major cultural phases that he identified. Despite problems of sediment transport and reworking, using a Bayesian statistical model the new dating program establishes a robust framework for the five major lithostratigraphic units identified in the stratigraphic succession, and for the major cultural units. The age of two anatomically modern human mandibles found by McBurney in Layer XXXIII near the base of his Levalloiso-Mousterian phase can now be estimated to between 73 and 65 ka (thousands of years ago) at the 95.4% confidence level, within Marine Isotope Stage (MIS) 4. McBurney's Layer XXV, associated with Upper Palaeolithic Dabban blade industries, has a clear stratigraphic relationship with Campanian Ignimbrite tephra. Microlithic Oranian technologies developed following the climax of the Last Glacial Maximum and the more microlithic Capsian in the Younger Dryas. Neolithic pottery and perhaps domestic livestock were used in the cave from the mid Holocene but there is no certain evidence for plant cultivation until the Graeco-Roman period.


Asunto(s)
Arqueología , Cuevas , Cronología como Asunto , Teorema de Bayes , Espectroscopía de Resonancia por Spin del Electrón , Fósiles , Sedimentos Geológicos/análisis , Humanos , Mediciones Luminiscentes , Datación Radiométrica
11.
Ophthalmic Physiol Opt ; 33(2): 94-103, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23406489

RESUMEN

PURPOSE: To evaluate the ease with which astigmats from three groups of current non-wearers of toric contact lenses can be fitted with current toric soft lenses, and to determine toric lens-wearing success. METHODS: This was a 1-month, randomized, bilateral, open-label, daily wear study involving 200 subjects and 16 investigational sites in the UK. Three groups of astigmatic subjects aged from 16 to 60 and with a mean age of 36 years (67 spherical soft contact lens users, SW; 72 contact lens drop-outs, DO; and 61 neophytes, Neo) were fitted with one of two toric soft lens types: a daily disposable toric soft lens (1 Day Acuvue Moist for Astigmatism, Johnson & Johnson Vision Care) or a 2-weekly replacement, re-usable toric soft lens (Acuvue Oasys for Astigmatism, Johnson & Johnson Vision Care). Subjects were evaluated after 1 month of wear and success rates calculated according to pre-set criteria for acceptable fit, orientation stability, visual acuity, quality of vision, and overall comfort. RESULTS: Eighty-eight percent of lenses were fitted at the first attempt. Of 198 subjects dispensed with lenses, 182 (92%) completed the study. When analysed by subject group, the success rates according to the pre-set criteria were 80% (53/66), 74% (52/70), and 70% (39/56) for the SW, DO and Neo groups respectively. Comfort was the most common reason for failure with all three groups; however, visual problems were more common in the DO and Neo groups (13% vs 6%). VA with the study lenses was significantly better in the SW group compared to their habitual lenses. For the DO and Neo groups combined (i.e. spectacle wearers), visual acuity was comparable to their habitual spectacles. CONCLUSIONS: A high proportion of astigmats who are not using toric soft contact lenses can be fitted with current lenses. Previous contact lens drop-outs and neophyte wearers achieve visual acuity comparable to spectacles when fitted with toric soft lenses. Spherical contact lens wearing astigmats achieve superior visual acuity when refitted with toric soft lenses. These findings suggest that many astigmats who are not currently using toric soft contact lenses could do so successfully.


Asunto(s)
Astigmatismo/rehabilitación , Lentes de Contacto Hidrofílicos , Adolescente , Adulto , Análisis de Varianza , Femenino , Humanos , Masculino , Persona de Mediana Edad , Satisfacción del Paciente , Reino Unido , Agudeza Visual , Adulto Joven
12.
Optom Vis Sci ; 89(12): 1682-90, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23190713

RESUMEN

PURPOSE: To estimate the prevalence of self-reported "sensitive eyes" (SEs) in soft contact lens (CL) wearers, evaluate the clinical characteristics of patients with SEs, and examine the effect of refitting them with silicone hydrogel lenses. METHODS: After self-assessment, 2154 CL wearers were separated into SE and non-SE patients. Demographics, biometric data, wearing time, symptoms, and signs were compared between the two populations. Sixty-three SE patients were randomized into senofilcon A (senA) lenses and 65 into a non-senA arm (lotrafilcon B, omafilcon A, and balafilcon A lenses). The performance of senA lenses was compared against habitual and non-senA lenses 2 weeks later. RESULTS: A total of 12.2% of CL wearers reported SEs with their habitual CLs. No significant differences were noticed between SE and non-SE patients in sex, age, or refraction. The prevalence of dryness (43 vs 19%, p < 0.0001), irritation (25 vs 11%, p < 0.0001), redness (20 vs 6%, p < 0.0001), and stinging (6 vs 1%, p < 0.0001) was higher in SE patients. Average wearing time (13.0 vs 14.1 hours, p < 0.0001) was lower in this group. Limbal/bulbar hyperemia and corneal/conjunctival staining were not significantly different between the two populations. Senofilcon A increased the number of patients reporting no dryness (habitual vs senA, 20 vs 44%, p < 0.0003), irritation (22 vs 37%, p = 0.015), redness (52 vs 76%, p =0.009) and stinging (58 vs 77%, p = 0.012) but did not significantly affect clinical signs. Senofilcon A was significantly more efficient than non-senA lenses in improving dryness (scale of 0 to 3: senA vs non-senA, 0.64 vs 1.02, p = 0.0056), irritation (0.72 vs 1.16, p = 0.0015), and stinging (0.18 vs 0.53, p = 0.0049). CONCLUSIONS: A substantial proportion of CL wearers report SEs with their habitual lenses. These patients are characterized by a high prevalence of additional symptoms, which are not reflected in clinical signs. Senofilcon A, or lenses with similar properties, may help reduce these symptoms in SE patients.


Asunto(s)
Enfermedades de la Conjuntiva/epidemiología , Lentes de Contacto Hidrofílicos/efectos adversos , Enfermedades de la Córnea/epidemiología , Hiperemia/epidemiología , Limbo de la Córnea/irrigación sanguínea , Adolescente , Adulto , Conjuntiva/irrigación sanguínea , Enfermedades de la Conjuntiva/diagnóstico , Enfermedades de la Conjuntiva/etiología , Enfermedades de la Córnea/diagnóstico , Enfermedades de la Córnea/etiología , Femenino , Estudios de Seguimiento , Humanos , Hiperemia/diagnóstico , Hiperemia/etiología , Masculino , Prevalencia , Ajuste de Prótesis , Errores de Refracción/terapia , Encuestas y Cuestionarios , Adulto Joven
13.
Optom Vis Sci ; 89(11): 1582-9, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23080059

RESUMEN

PURPOSE: To evaluate predisposing factors in subjects susceptible to solution-induced corneal staining (SICS). METHODS: Four hundred forty-six existing soft contact lens wearers were randomly fitted with one of two study lenses (lotrafilcon B, CIBA Vision, or omafilcon A, CooperVision) and used a hydrogen peroxide care system (Clear Care, CIBAVision) for a 1-month period. Each subject was then challenged with the same lenses presoaked in a multipurpose solution (ReNu MultiPlus, Bausch & Lomb) and assessed after approximately 2 h to be categorized as either "stainers" or "non-stainers" based on whether they showed a classic SICS pattern (diffuse punctate corneal staining in three or more peripheral quadrants). RESULTS: Overall, 36% (155 of 425) of eligible subjects were classified as stainers and included a higher proportion of omafilcon wearers: 44% (91 of 205) vs. 29% (64 of 220). After using the peroxide system, the stainers were more likely to show poorer wetting (odds ratio [OR] = 1.76, p = 0.02) compared with the non-stainers. Lens wetting showed a significant negative correlation with film deposits (r = -0.63, p < 0.0001, n = 425). Furthermore, on slit lamp examination, the stainers were more likely to show higher levels of upper- and lower-palpebral hyperemia (OR = 2.18, p = 0.02; OR = 1.93, p = 0.04), tarsal roughness (OR = 1.71, p = 0.01), corneal staining (OR = 17.1, p < 0.0001), and conjunctival staining (OR = 1.94, p = 0.004). Although not exposed to preservatives, twice as many eyes in the stainers group had some level of corneal staining: 51% vs. 25%. There were no significant differences between the stainers and non-stainers with respect to age, sex, refraction, or keratometry (p > 0.05). CONCLUSIONS: This study highlighted some notable trends in patients susceptible to SICS. The findings point toward poor tear quality as a predisposing factor for SICS.


Asunto(s)
Soluciones para Lentes de Contacto/farmacología , Lentes de Contacto de Uso Prolongado , Córnea/efectos de los fármacos , Coloración y Etiquetado/métodos , Adolescente , Adulto , Anciano , Córnea/citología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
14.
Optom Vis Sci ; 89(8): 1125-32, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22820475

RESUMEN

PURPOSE: To report demographics, wearing patterns, and symptoms from soft contact lens (SCL) wearers with significant SCL-related dryness symptoms with and without significant ocular signs of dryness. METHODS: In a multicenter, prospective observational clinical trial, symptomatic SCL wearers reported significant SCL-related dryness via self-administered questionnaire of frequency and intensity of dryness after a dry eye (DE) examination. DE etiology was assigned post hoc by an expert panel, and those with and without significant DE-related signs were analyzed by univariate logistic regression. Possible DE etiologies were aqueous tear deficiency, SCL-induced tear instability, meibomian gland dysfunction, or "other." Wearers without signs that qualified for any DE etiology were designated as No DE Signs (NDES). RESULTS: Of the 226 SCL symptomatic wearers examined, 23% were without signs, 30% had aqueous tear deficiency, 25% had SCL-induced tear instability, 14% had meibomian gland dysfunction, and 8% had "other" diagnoses. The NDES wearers had significantly longer pre-lens break-up time (9.8 vs. 6.6 s, p < 0.0001), better lens wetting (3.4 vs. 2.4 0 to 4 scale, p < 0.0001), lower levels of film deposits on lenses (0.45 vs. 0.92, 0 to 4 scale, p < 0.0001), and of most slit lamp signs. The NDES wearers were significantly more likely to be male (36% vs.19%, p = 0.013), were less likely to have deteriorating comfort during the day (81% vs. 97%, p = 0.001), reported longer average hours of comfortable wear (11 ± 3 vs. 9 ± 4 h, p = 0.014), had older contact lenses (18 ± 14 vs. 13 ± 12 days, p = 0.029), and greater intensity of photophobia early and late in the day (p = 0.043 and 0.021). CONCLUSIONS: Symptoms of dryness in SCL wearers stem from a variety of underlying causes. However, nearly one-quarter of these symptomatic SCL wearers appear to be free of signs of dryness. The effective management of CL-related dryness requires a comprehensive range of clinical assessments and the use of a diverse range of management strategies.


Asunto(s)
Lentes de Contacto Hidrofílicos/efectos adversos , Síndromes de Ojo Seco/etiología , Satisfacción del Paciente , Lágrimas/fisiología , Adulto , Síndromes de Ojo Seco/fisiopatología , Femenino , Humanos , Masculino , Estudios Prospectivos , Encuestas y Cuestionarios
15.
Eye Contact Lens ; 37(1): 20-5, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21178696

RESUMEN

PURPOSE: To estimate the proportion of potential soft contact lens wearers requiring an astigmatic correction and to estimate the proportion of astigmats who can be accommodated with toric soft lenses of varying prescription range. METHOD: A database of 11,624 spectacle prescriptions was used to calculate the prevalence of astigmatism for various thresholds (0.50-2.00 DC) by eye and by patient. The coverage of various prescription ranges was estimated using a subset of the database comprising those patients with at least 0.75 D of astigmatism in at least one eye (n = 5,444). RESULTS: The prevalence of patients showing astigmatism of 0.75 and 1.00 D or greater in at least one eye was 47.4% and 31.8% and, in both eyes, 24.1% and 15.0%, respectively. The proportion of eyes showing astigmatism greater than or equal to 0.75, 1.00, 1.50, and 2.00 D was 35.7%, 23.4%, 10.8%, 5.6%, respectively. The prevalence of astigmatism of 0.75 D or greater was almost double in myopes compared with hyperopes: 31.7% vs. 15.7%. The prevalence of with-the-rule (WTR) astigmatism was higher than against-the-rule (32.9% vs. 29.1%); the proportion was also higher for WTR in eyes with astigmatism ≥0.75 D (15.3% vs. 14.5%). We estimate that approximately one third of potential contact lens wearers require astigmatic correction. A stock range of toric soft lenses in sphere powers +6.00 to -9.00 D, three cylinder powers, and 18 axes requires nearly 3,000 prescriptions and provides coverage for 90% of astigmats. CONCLUSION: These findings provide an estimate of the proportion of soft contact lens patients requiring an astigmatic correction and some useful insights into the proportion of astigmats covered by toric soft lens stocks of varying range.


Asunto(s)
Astigmatismo/epidemiología , Astigmatismo/rehabilitación , Lentes de Contacto Hidrofílicos , Ajuste de Prótesis , Adolescente , Adulto , Anciano , Niño , Diseño de Equipo , Humanos , Persona de Mediana Edad , Miopía/rehabilitación , Prescripciones , Prevalencia , Resultado del Tratamiento , Adulto Joven
16.
Cont Lens Anterior Eye ; 44(4): 101391, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33549474

RESUMEN

PURPOSE: To report on the ocular health and safety of children fit with soft hydrogel daily-disposable contact lenses, and followed for 6-years in a double-masked clinical trial investigating the performance of a dual-focus contact lens designed to control myopia progression. METHODS: Children aged 8-12 years, naïve to contact lens wear, were enrolled across four international sites. During years 1-3, children were randomised to either MiSight® 1 day or Proclear® 1 day (both omafilcon A, CooperVision, Inc.). The lenses were identical in material and geometry except for the front optical zone design. At the end of year-3, all those wearing Proclear 1 day were switched to MiSight 1 day, therefore all wore MiSight 1 day in years 4-6. Subjects agreed to wear the lenses at least 10-hours/day, 6-days/week. After dispensing, study visits were at 1-week, 1-month, 6-months and every 6-months until 6-years. At each visit, ocular measurements and subjective responses were recorded. Biomicroscopy used 0-4 grading scales; grade 0 represented no findings. RESULTS: 144 children were enrolled: 69F:75M; mean age 10.1 years; mean cycloplegic spherical-equivalent refraction -2.11D; ethnicities included 34 East-Asian, 12 West-Asian, and 79 Caucasian. 92 completed the 6-years. Only three subjects discontinued due to an ocular adverse event (AE). No contact lens related AEs were classified as serious. The incidence rate of infiltrative AEs was 0.61% (6.1/1000 wearing-years; 95%CI: 0.24%-1.57%). The most common biomicroscopy findings were limbal, bulbar and tarsal hyperaemia and tarsal roughness. 99% of all biomicroscopy findings were grade-1 or lower. After 6-years of lens wear, ocular health by biomicroscopy was similar to pre-lens wear. CONCLUSIONS: Across the 6-years, there were no contact lens related serious AEs and biomicroscopy showed no significant changes. Results suggest that children this age can successfully wear daily-disposable hydrogel contact lenses with minimal impact on ocular physiology.


Asunto(s)
Lentes de Contacto Hidrofílicos , Miopía , Niño , Equipos Desechables , Humanos , Miopía/terapia , Satisfacción del Paciente , Refracción Ocular , Visión Ocular
17.
Optom Vis Sci ; 87(5): 358-66, 2010 May.
Artículo en Inglés | MEDLINE | ID: mdl-20386354

RESUMEN

PURPOSE: To determine which ocular topography variables affect soft contact lens fit. METHODS: Fifty subjects each wore three pairs of soft lenses in random succession (Vistakon Acuvue 2, Vistakon Acuvue Advance, Ciba Vision Night & Day), and various aspects of lens fit were evaluated. The steeper base curves of each type were worn in one eye and the flatter base curves in the other eye. Corneal topography data were collected using a Medmont E300 corneal topographer (Camberwell, Australia). Corneal curvature, shape factor (SF), and corneal height were measured over a 10 mm chord and also over the maximum measurable diameter. These were measured in the horizontal, vertical, steepest, and flattest meridians. RESULTS: With each lens type, the steeper base curve provided the best fit on the greatest proportion of eyes and the significant differences in various aspects of fit were noted between base curves. For each lens type, there was no significant difference in mean K-reading between those eyes best fit with the steeper base curve and those eyes best fit with the flatter base curve. Two of the lenses showed a positive correlation between centration and horizontal corneal height (maximum), whereas one lens showed a negative correlation between centration and horizontal SF (SF = e). Several lenses showed a positive correlation between post-blink movement and horizontal or vertical corneal SF. CONCLUSIONS: The measurement of corneal topography using current Placido disc instrumentation allows a better prediction of soft lens fit than by keratometry, but it is not reliable enough to enable accurate selection of the best fitting base curve. Some correlations are evident between corneal measurements; however, trial fitting remains the method of choice for selection of soft lens base curve.


Asunto(s)
Lentes de Contacto Hidrofílicos , Córnea/patología , Topografía de la Córnea/instrumentación , Miopía/patología , Adulto , Diseño de Equipo , Femenino , Humanos , Masculino , Miopía/fisiopatología , Miopía/rehabilitación , Valor Predictivo de las Pruebas , Refracción Ocular
18.
Optom Vis Sci ; 86(11): E1259-66, 2009 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-19789457

RESUMEN

PURPOSE: To evaluate the comparative orientation characteristics of currently available silicone hydrogel torics. METHODS: The re-orientation characteristics of four toric lenses were assessed: three prism-ballasted (PB) designs, Purevision Toric (PVT), Air Optix Toric (AOT), Proclear Toric (PCT), and an "Accelerated Stabilization Design" (ASD) ACUVUE ADVANCE for Astigmatism (AAfA). In the first part of the study, the toric lenses were rotated, approximately 45 degrees in the infero-temporal direction and a video recording of lens reorientation was made from which blink-by-blink measurements of lens orientation were taken. In the second part of the study, subjects were positioned with their head orientated 90 degrees to the vertical and lens orientation photographed once it had settled. RESULTS: In Part 1, the speed of re-orientation from oblique mis location was similar for the four designs tested and ranged from 22°/min (PVT) to25°/min (AOT). Lenses showed more rotation during rather than between the blink (p<0.0001). Between blinks, AAfA and AOT showed significantly more rotation than PCT and PVT (p0.04). There were no significant differences between lenses for rotation during the blink. The PB lenses showed faster re-orientation further away from the zero position.AAfA showed no significant difference in rotation speed with varying orientation position. In Part 2, all the PB lenses rotated significantly more under the effect of gravity than the ASD lenses.The mean total rotation of the AAfA lenses,from their settled position, was 11.4° compared with 25.9° for PVT (p0.01), 18.4° with AOT (p0.02) and 37.4° with PCT (p0.0002) [corrected]. The mean total rotation of the AAfA lenses, from their settled position, was 11.2 degrees compared with 32.8 degrees for PVT (p < 0.001), 16.1 degrees with AOT and 33.1 degrees with PCT (p < 0.001). CONCLUSIONS: The four lens designs show similar re-orientation speeds. In the recumbent position, PB lenses rotate more from their normal settled position than ASD lenses.


Asunto(s)
Parpadeo , Lentes de Contacto Hidrofílicos , Rotación , Diseño de Equipo , Gravitación , Humanos , Orientación , Ajuste de Prótesis , Factores de Tiempo , Grabación en Video
19.
Eye Contact Lens ; 35(2): 50-8, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19265324

RESUMEN

PURPOSE: To clinically evaluate long-term users of two different contact lens care preservative systems and to investigate whether prolonged use is associated with an increase in the prevalence of dry eye. METHODS: Eighty-nine wearers of group IV hydrogel or silicone hydrogel lenses participated in this one-visit, investigator-masked study. Subjects were required to have consistently used a polyhexamethylene biguanide (PHMB) or polyquaternium-1 (PQT) based solution for 2 years. Consistent use was defined as 80% for the past 2 years and 100% for the past year. Clinical assessments included: average and comfortable wear time; overall and end-of-day comfort; signs of dryness, discomfort, burning or stinging, grittiness or scratchiness and visual changes; non-invasive and fluorescein break-up-time; pre-ocular tear film lipids, tear meniscus height, Schirmer and fluorescein clearance tests; limbal and bulbar hyperemia; palpebral roughness; corneal and conjunctival staining; lens front surface wetting; and lens film deposits. RESULTS: Significantly more grittiness or scratchiness was reported by subjects using a PHMB-containing system (67% vs. 44%; P = 0.02). Palpebral roughness and hyperemia were significantly greater in the PHMB group wearing group IV lenses (P = 0.01 and P = 0.05, respectively). Corneal staining was significantly higher in the PHMB users in all four peripheral sectors (P < 0.01). Nasal and temporal conjunctival staining was also significantly higher for users of PHMB-containing systems (P < 0.05). Front surface lens wettability was significantly better for group IV PQT users compared to PHMB users (P = 0.008), with 84% vs. 72%, respectively, with lenses graded by the investigator as having "good" or "excellent" wettability. Significantly higher levels of lens front surface film deposits were noted with PHMB users (P = 0.007), with 58% of group IV lenses treated with PHMB compared with 38% of group IV lenses treated with PQT showing some lens front surface film deposition. No significant differences between the two preservative system groups were noted for the range of dry eye evaluations nor the remaining clinical assessments. CONCLUSIONS: Differences in both ocular and lens characteristic were observed between long-term users of two preservative systems used in many contact lens multi-purpose solutions. The findings from this study did not support the hypothesis that prolonged use of PHMB-containing solutions leads to dry eye. Additional studies including a larger sample size and perhaps longer use of the systems could help to further elucidate differences in clinical performance between systems.


Asunto(s)
Biguanidas , Soluciones para Lentes de Contacto , Lentes de Contacto Hidrofílicos , Desinfectantes , Polímeros , Conservadores Farmacéuticos , Biguanidas/efectos adversos , Biguanidas/farmacología , Conjuntiva/efectos de los fármacos , Soluciones para Lentes de Contacto/química , Córnea/efectos de los fármacos , Desinfectantes/efectos adversos , Desinfectantes/farmacología , Humanos , Hidrogel de Polietilenoglicol-Dimetacrilato , Hiperemia/inducido químicamente , Polímeros/efectos adversos , Polímeros/farmacología , Conservadores Farmacéuticos/efectos adversos , Conservadores Farmacéuticos/farmacología , Siliconas , Método Simple Ciego , Lágrimas/efectos de los fármacos , Factores de Tiempo , Humectabilidad/efectos de los fármacos , Xeroftalmia/inducido químicamente
20.
Biosensors (Basel) ; 8(2)2018 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-29596396

RESUMEN

Imaging photoplethysmography (iPPG) is an emerging technology used to assess microcirculation and cardiovascular signs by collecting backscattered light from illuminated tissue using optical imaging sensors. The aim of this study was to study how effective smart garment fabrics could be capturing physiological signs in a non-contact mode. The present work demonstrates a feasible approach of, instead of using conventional high-power illumination sources, integrating a grid of surface-mounted light emitting diodes (LEDs) into cotton fabric to spotlight the region of interest (ROI). The green and the red LEDs (525 and 660 nm) placed on a small cotton substrate were used to locally illuminate palm skin in a dual-wavelength iPPG setup, where the backscattered light is transmitted to a remote image sensor through the garment fabric. The results show that the illuminations from both wavelength LEDs can be used to extract heart rate (HR) reaching an accuracy of 90% compared to a contact PPG probe. Stretching the fabric over the skin surface alters the morphology of iPPG signals, demonstrating a significantly higher pulsatile amplitude in both channels of green and red illuminations. The skin compression by the fabric could be potentially utilised to enhance the penetration of illumination into cutaneous microvascular beds. The outcome could lead a new avenue of non-contact opto-physiological monitoring and assessment with functional garment fabrics.


Asunto(s)
Vestuario/normas , Procesamiento de Imagen Asistido por Computador/métodos , Monitoreo Fisiológico/métodos , Fenómenos Fisiológicos de la Piel/inmunología , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA