RESUMEN
Scalable generation of genuine multipartite entanglement with an increasing number of qubits is important for both fundamental interest and practical use in quantum-information technologies1,2. On the one hand, multipartite entanglement shows a strong contradiction between the prediction of quantum mechanics and local realization and can be used for the study of quantum-to-classical transition3,4. On the other hand, realizing large-scale entanglement is a benchmark for the quality and controllability of the quantum system and is essential for realizing universal quantum computing5-8. However, scalable generation of genuine multipartite entanglement on a state-of-the-art quantum device can be challenging, requiring accurate quantum gates and efficient verification protocols. Here we show a scalable approach for preparing and verifying intermediate-scale genuine entanglement on a 66-qubit superconducting quantum processor. We used high-fidelity parallel quantum gates and optimized the fidelitites of parallel single- and two-qubit gates to be 99.91% and 99.05%, respectively. With efficient randomized fidelity estimation9, we realized 51-qubit one-dimensional and 30-qubit two-dimensional cluster states and achieved fidelities of 0.637 ± 0.030 and 0.671 ± 0.006, respectively. On the basis of high-fidelity cluster states, we further show a proof-of-principle realization of measurement-based variational quantum eigensolver10 for perturbed planar codes. Our work provides a feasible approach for preparing and verifying entanglement with a few hundred qubits, enabling medium-scale quantum computing with superconducting quantum systems.
RESUMEN
Genetic studies of blood pressure (BP) traits to date have been performed on conventional measures by brachial cuff sphygmomanometer for systolic BP (SBP) and diastolic BP, integrating several physiologic occurrences. Genetic associations with central SBP (cSBP) have not been well-studied. Genetic discovery studies of BP have been most often performed in European-ancestry samples. Here, we investigated genetic associations with cSBP in a Chinese population and functionally validated the impact of a novel associated coiled-coil domain containing 93 (CCDC93) gene on BP regulation. An exome-wide association study (EWAS) was performed using a mixed linear model of non-invasive cSBP and peripheral BP traits in a Han Chinese population (N = 5,954) from Beijing, China genotyped with a customized Illumina ExomeChip array. We identified four SNP-trait associations with three SNPs, including two novel associations (rs2165468-SBP and rs33975708-cSBP). rs33975708 is a coding variant in the CCDC93 gene, c.535C>T, p.Arg179Cys (MAF = 0.15%), and was associated with increased cSBP (ß = 29.3 mmHg, P = 1.23x10-7). CRISPR/Cas9 genome editing was used to model the effect of Ccdc93 loss in mice. Homozygous Ccdc93 deletion was lethal prior to day 10.5 of embryonic development. Ccdc93+/- heterozygous mice were viable and morphologically normal, with 1.3-fold lower aortic Ccdc93 protein expression (P = 0.0041) and elevated SBP as compared to littermate Ccdc93+/+ controls (110±8 mmHg vs 125±10 mmHg, P = 0.016). Wire myography of Ccdc93+/- aortae showed impaired acetylcholine-induced relaxation and enhanced phenylephrine-induced contraction. RNA-Seq transcriptome analysis of Ccdc93+/- mouse thoracic aortae identified significantly enriched pathways altered in fatty acid metabolism and mitochondrial metabolism. Plasma free fatty acid levels were elevated in Ccdc93+/- mice (96±7mM vs 124±13mM, P = 0.0031) and aortic mitochondrial dysfunction was observed through aberrant Parkin and Nix protein expression. Together, our genetic and functional studies support a novel role of CCDC93 in the regulation of BP through its effects on vascular mitochondrial function and endothelial function.
Asunto(s)
Presión Sanguínea , Mitocondrias , Polimorfismo de Nucleótido Simple , Proteínas de Transporte Vesicular , Animales , Femenino , Humanos , Masculino , Ratones , Persona de Mediana Edad , Presión Sanguínea/genética , Estudio de Asociación del Genoma Completo , Hipertensión/genética , Mitocondrias/genética , Mitocondrias/metabolismo , Vasodilatación/genética , Pueblos del Este de Asia/genética , Proteínas de Transporte Vesicular/genéticaRESUMEN
BACKGROUND AND AIMS: INTERASPIRE is an international study of coronary heart disease (CHD) patients, designed to measure if guideline standards for secondary prevention and cardiac rehabilitation are being achieved in a timely manner. METHODS: Between 2020 and 2023, adults hospitalized in the preceding 6-24 months with incident or recurrent CHD were sampled in 14 countries from all 6 World Health Organization regions and invited for a standardized interview and examination. Direct age and sex standardization was used for country-level prevalence estimation. RESULTS: Overall, 4548 (21.1% female) CHD patients were interviewed a median of 1.05 (interquartile range .76-1.45) years after index hospitalization. Among all participants, 24.6% were obese (40.7% centrally). Only 38.6% achieved a blood pressure (BP) < 130/80â mmHg and 16.6% a LDL cholesterol (LDL-C) of <1.4â mmol/L. Of those smoking at hospitalization, 48% persisted at interview. Of those with known diabetes, 55.2% achieved glycated haemoglobin (HbA1c) of <7.0%. A further 9.8% had undetected diabetes and 26.9% impaired glucose tolerance. Females were less likely to achieve the targets: BP (females 36.8%, males 38.9%), LDL-C (females 12.0%, males 17.9%), and HbA1c in diabetes (females 47.7%, males 57.5%). Overall, just 9.0% (inter-country range 3.8%-20.0%) reported attending cardiac rehabilitation and 1.0% (inter-country range .0%-2.4%) achieved the study definition of optimal guideline adherence. CONCLUSIONS: INTERASPIRE demonstrates inadequate and heterogeneous international implementation of guideline standards for secondary prevention in the first year after CHD hospitalization, with geographic and sex disparity. Investment aimed at reducing between-country and between-individual variability in secondary prevention will promote equity in global efforts to reduce the burden of CHD.
Asunto(s)
Enfermedad Coronaria , Prevención Secundaria , Humanos , Prevención Secundaria/métodos , Femenino , Masculino , Persona de Mediana Edad , Enfermedad Coronaria/prevención & control , Enfermedad Coronaria/epidemiología , Anciano , Hospitalización/estadística & datos numéricos , Rehabilitación Cardiaca , Adhesión a Directriz/estadística & datos numéricos , Guías de Práctica Clínica como AsuntoRESUMEN
VEXAS syndrome, an uncommon yet severe autoimmune disorder stemming from a mutation in the UBA1 gene, is the focus of this paper. The overview encompasses its discovery, epidemiological traits, genetic underpinnings, and clinical presentations. Delving into whether distinct genotypes yield varied clinical phenotypes in VEXAS patients, and the consequent adjustment of treatment strategies based on genotypic and clinical profiles necessitates thorough exploration within the clinical realm. Additionally, the current therapeutic landscape and future outlook are examined, with particular attention to the potential therapeutic roles of IL-6 inhibitors and JAK inhibitors, alongside an elucidation of prevailing limitations and avenues for further research. This study contributes essential theoretical groundwork and clinical insights for both diagnosing and managing VEXAS syndrome.
Asunto(s)
Interleucina-6 , Inhibidores de las Cinasas Janus , Enzimas Activadoras de Ubiquitina , Humanos , Interleucina-6/genética , Interleucina-6/metabolismo , Inhibidores de las Cinasas Janus/uso terapéutico , Enzimas Activadoras de Ubiquitina/genética , Enzimas Activadoras de Ubiquitina/antagonistas & inhibidores , Mutación , Enfermedades Autoinmunes/tratamiento farmacológico , Enfermedades Autoinmunes/genética , Enfermedades Autoinmunes/diagnósticoRESUMEN
Quantum non-Gaussianity, a more potent and highly useful form of nonclassicality, excludes all convex mixtures of Gaussian states and Gaussian parametric processes generating them. Here, for the first time, we conclusively test quantum non-Gaussian coincidences of entangled photon pairs with the Clauser-Horne-Shimony-Holt-Bell factor S=2.328±0.004 from a single quantum dot with a depth up to 0.94±0.02 dB. Such deterministically generated photon pairs fundamentally overcome parametric processes by reducing crucial multiphoton errors. For the quantum non-Gaussian depth of the unheralded (heralded) single-photon state, we achieve the value of 8.08±0.05 dB (19.06±0.29 dB). Our Letter experimentally certifies the exclusive quantum non-Gaussianity properties highly relevant for optical sensing, communication, and computation.
RESUMEN
A solid-state approach for quantum networks is advantageous, as it allows the integration of nanophotonics to enhance the photon emission and the utilization of weakly coupled nuclear spins for long-lived storage. Silicon carbide, specifically point defects within it, shows great promise in this regard due to the easy of availability and well-established nanofabrication techniques. Despite of remarkable progresses made, achieving spin-photon entanglement remains a crucial aspect to be realized. In this Letter, we experimentally generate entanglement between a silicon vacancy defect in silicon carbide and a scattered single photon in the zero-phonon line. The spin state is measured by detecting photons scattered in the phonon sideband. The photonic qubit is encoded in the time-bin degree of freedom and measured using an unbalanced Mach-Zehnder interferometer. Photonic correlations not only reveal the quality of the entanglement but also verify the deterministic nature of the entanglement creation process. By harnessing two pairs of such spin-photon entanglement, it becomes straightforward to entangle remote quantum nodes at long distance.
RESUMEN
In the quest to build general-purpose photonic quantum computers, fusion-based quantum computation has risen to prominence as a promising strategy. This model allows a ballistic construction of large cluster states which are universal for quantum computation, in a scalable and loss-tolerant way without feed forward, by fusing many small n-photon entangled resource states. However, a key obstacle to this architecture lies in efficiently generating the required essential resource states on photonic chips. One such critical seed state that has not yet been achieved is the heralded three-photon Greenberger-Horne-Zeilinger (3-GHZ) state. Here, we address this elementary resource gap, by reporting the first experimental realization of a heralded 3-GHZ state. Our implementation employs a low-loss and fully programmable photonic chip that manipulates six indistinguishable single photons of wavelengths in the telecommunication regime. Conditional on the heralding detection, we obtain the desired 3-GHZ state with a fidelity 0.573±0.024. Our Letter marks an important step for the future fault-tolerant photonic quantum computing, leading to the acceleration of building a large-scale optical quantum computer.
RESUMEN
Transcatheter pulmonary valve replacement (TPVR), also known as percutaneous pulmonary valve implantation, refers to a minimally invasive technique that replaces the pulmonary valve by delivering an artificial pulmonary prosthesis through a catheter into the diseased pulmonary valve under the guidance of X-ray and/or echocardiogram while the heart is still beating not arrested. In recent years, TPVR has achieved remarkable progress in device development, evidence-based medicine proof and clinical experience. To update the knowledge of TPVR in a timely fashion, and according to the latest research and further facilitate the standardized and healthy development of TPVR in Asia, we have updated this consensus statement. After systematical review of the relevant literature with an in-depth analysis of eight main issues, we finally established eight core viewpoints, including indication recommendation, device selection, perioperative evaluation, procedure precautions, and prevention and treatment of complications.
Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Válvula Pulmonar , Humanos , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Resultado del Tratamiento , Asia , CatéteresRESUMEN
Randomized clinical trials (RCTs) of PCSK9 monoclonal antibody(mAb) specifically for Chinese patients have been limited. This multi-center RCT is to clarify the efficacy and safety of a novel mAb, Ebronucimab, in Chinese patients. Patients diagnosed with primary hypercholesterolemia, including Heterozygous Familial Hypercholesterolemia, or mixed dyslipidemia, were categorized by ASCVD risk and randomly assigned at a ratio of 2:1:2:1 to receive Ebronucimab 450â¯mg or matching placebo every 4 weeks (Q4W), or Ebronucimab 150â¯mg or matching placebo every 2 weeks (Q2W). The primary outcome was the percentage change of LDL-C from baseline to week 12 for all groups. The least squares mean reduction difference (95â¯%CI) in LDL-C from baseline to week 12 of Ebronucimab 450â¯mg Q4W and Ebronucimab 150â¯mg Q2W groups versus the placebo group was -59.13 (-64.103, -54.153) (Adjusted p<0.0001) and -60.43 (-65.450, -55.416) (Adjusted p<0.0001), respectively. Meanwhile, the Ebronucimab group exhibited notably high rates in reaching LDL-C goals of each cardiovascular risk stratification. In addition, Ebronucimab effectively improved other lipid panel. During the double-blind treatment period, relatively frequently reported adverse events (AEs) were injection site reactions (ISR), urinary tract infection, and hyperuricemia (Incidence rate are 6.9â¯%, 4.8â¯% and 3.5â¯%). Among treatment-associated AEs, only injection site reactions (ISR) occurred more in the dose groups. In conclusion, Ebronucimab, with either 450â¯mg Q4W or 150â¯mg Q2W doses, demonstrated significant efficacy in lowering serum LDL-C level with a favorable safety and immunogenicity profile among hypercholesterolemic patients.
Asunto(s)
Anticuerpos Monoclonales Humanizados , LDL-Colesterol , Hipercolesterolemia , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Anticuerpos Monoclonales Humanizados/efectos adversos , Anticuerpos Monoclonales Humanizados/uso terapéutico , Anticolesterolemiantes/uso terapéutico , Anticolesterolemiantes/efectos adversos , China , LDL-Colesterol/sangre , Método Doble Ciego , Pueblos del Este de Asia , Hipercolesterolemia/tratamiento farmacológico , Proproteína Convertasa 9 , Resultado del TratamientoRESUMEN
BACKGROUND AND PURPOSE: Hypertension significantly contributes to stroke. Previous research has indicated a connection between daytime napping and stroke. Research on the connection between daytime napping duration and first stroke in hypertensive individuals is lacking nevertheless. METHODS: This research, which ran from 24 August 2013 to 31 December 2022, recruited 11,252 individuals with hypertension and without a history of stroke from the China Stroke Primary Prevention Trial. To determine the relationship between daytime napping duration and stroke onset in hypertensive individuals, we conducted analyses for threshold effects, multivariate-adjusted Cox proportional hazard regression models, and Kaplan-Meier survival curves. RESULTS: The duration of daytime napping (<75 min) was positively correlated with stroke risk; beyond 75 min, the risk did not increase further. When compared to hypertensive individuals who napped for 1-30 min, daytime napping 31-60 min (hazard ratio [HR] = 1.27, 95% confidence interval [CI] = 1.06-1.53) and >60 min (HR = 1.37, 95% CI = 1.14-1.65) were substantially related with a greater risk of first stroke. Additionally, this correlation was absent in cases of hemorrhagic stroke, but present in cases of ischemic stroke, specifically for hypertensive individuals who napped for 31-60 min or >60 min (p < 0.05). Kaplan-Meier survival curves displayed that hypertensive individuals who extended daytime napping had an elevated incidence of stroke. CONCLUSIONS: Hypertensive individuals who take longer daytime naps (>30 min) are at an elevated risk of stroke onset, particularly ischemic stroke, irrespective of other factors.
Asunto(s)
Hipertensión , Sueño , Accidente Cerebrovascular , Humanos , Masculino , Hipertensión/epidemiología , Hipertensión/complicaciones , Femenino , Persona de Mediana Edad , Sueño/fisiología , Anciano , Accidente Cerebrovascular/epidemiología , China/epidemiología , Factores de Tiempo , Factores de Riesgo , Accidente Cerebrovascular Isquémico/epidemiologíaRESUMEN
BACKGROUND: While folic acid (FA) is widely used to treat elevated total homocysteine (tHcy), promoting vascular health by reducing vascular oxidative stress and modulating endothelial nitric oxide synthase, the optimal daily dose and individual variation by MTHFR C677T genotypes have not been well studied. Therefore, this study aimed to explore the efficacy of eight different FA dosages on tHcy lowering in the overall sample and by MTHFR C677T genotypes. METHODS: This multicentered, randomized, double-blind, controlled clinical trial included 2697 eligible hypertensive adults with elevated tHcy (≥ 10 mmol/L) and without history of stroke and cardiovascular disease. Participants were randomized into eight dose groups of FA combined with 10 mg enalapril maleate, taken daily for 8 weeks of treatment. RESULTS: The intent to treat analysis included 2163 participants. In the overall sample, increasing FA dosage led to steady tHcy reduction within the FA dosing range of 0-1.2 mg. However, a plateau in tHcy lowering was observed in FA dose range of 1.2-1.6 mg, indicating a ceiling effect. In contrast, FA doses were positively and linearly associated with serum folate levels without signs of plateau. Among MTHFR genotype subgroups, participants with the TT genotype showed greater efficacy of FA in tHcy lowering. CONCLUSIONS: This randomized trial lent further support to the efficacy of FA in lowering tHcy; more importantly, it provided critically needed evidence to inform optimal FA dosage. We found that the efficacy of FA in lowering tHcy reaches a plateau if the daily dosage exceeds 1.2 mg, and only has a small gain by increasing the dosage from 0.8 to 1.2 mg. GOV IDENTIFIER: NCT03472508 (Registration Date: March 21, 2018).
Asunto(s)
Ácido Fólico , Genotipo , Homocisteína , Metilenotetrahidrofolato Reductasa (NADPH2) , Humanos , Ácido Fólico/administración & dosificación , Ácido Fólico/sangre , Homocisteína/sangre , Femenino , Masculino , Método Doble Ciego , Persona de Mediana Edad , Metilenotetrahidrofolato Reductasa (NADPH2)/genética , Hipertensión/tratamiento farmacológico , Relación Dosis-Respuesta a Droga , Anciano , Enalapril/administración & dosificación , Enalapril/farmacología , Adulto , Hiperhomocisteinemia/tratamiento farmacológico , Hiperhomocisteinemia/sangreRESUMEN
OBJECTIVE: To explore the relationship between lipid metabolism molecules in plasma and carotid atherosclerotic plaques, traditional cardiovascular risk factors and possible dietary related factors. METHODS: Firstly, among 1 312 community people from those who participated in a 10-year follow-up study of subclinical atherosclerosis cohort in Shijingshan District, Beijing, 85 individuals with 2 or more carotid soft plaques or mixed plaques and 89 healthy individuals without plaques were selected according to the inclusive and the exclusive criteria (< 70 years, not having clinical cardiovascular disease and other diseases, etc.). Secondly, 10 cases and 10 controls were randomly selected in the above 85 and 89 individuals respectively. Carotid plaques were detected using GE Vivid i Ultrasound Machine with 8L detector. Lipid metabolism molecules were detected by high performance liquid chromatography-mass spectrometry. The detection indexes included 113 lipid metabolism molecules. Traditional cardiovascular risk factors were collected by unified standard questionnaires, and dietary related factors were collected by main dietary frequency and weight scale. The difference of lipid metabolism molecules between the case group and the control group was analyzed by Wilcoxin rank test. In the control group, the Spearman correlation method was used to analyze the correlation between statistically significant lipid metabolism molecules and traditional cardiovascular risk factors and dietary factors. RESULTS: Among the 113 lipid metabolism molecules, 53 lipid metabolism molecules were detected. C24:0 sphingomyelin (SM), C22:0/ C24:0 ceramide molecules, C18:0 phosphoethanolamine (PE) molecules, and C18:0/C18:2 (Cis) phosphatidylcholine (PC) were significantly higher in the carotid atherosclerotic plaque group than in the control group. The correlation analysis showed that C24:0 SM was significantly positively correlated with low density lipoprotein cholesterol (LDL-C, r=0.636, P < 0.05), C18:2 (Cis) PC (DLPC) was significantly positively correlated with systolic pressure (r=0.733, P < 0.05), C18:0 PE was significantly positively correlated with high sensitivity C-response protein (r=0.782, P < 0.01), C22:0, C24:0 ceramide and C18:0 PE were negatively correlated with vegetable intake (r=-0.679, P < 0.05;r=-0.711, P < 0.05;r=-0.808, P < 0.01), C24:0 ceramide was also negatively correlated with beans food intake (r=-0.736, P < 0.05) in the control group. CONCLUSIONS: The increase of plasma C24:0 SM, C22:0, C24:0 ceramide, C18:0 PE, C18:2 (Cis) PC (DLPC), C18:0 PC (DSPC) may be new risk factors for human atherosclerotic plaques. These molecules may be related to blood lipid, blood pressure or inflammatory level and the intake of vegetables and soy products, but the nature of the association needs to be verified in a larger sample population.
Asunto(s)
Dieta , Metabolismo de los Lípidos , Placa Aterosclerótica , Humanos , Placa Aterosclerótica/sangre , Masculino , Femenino , Factores de Riesgo de Enfermedad Cardiaca , Factores de Riesgo , Enfermedades de las Arterias Carótidas/sangre , Anciano , Enfermedades Cardiovasculares/sangre , Enfermedades Cardiovasculares/etiología , Persona de Mediana Edad , Esfingomielinas/sangre , Ceramidas/sangre , Ceramidas/metabolismo , Estudios de Seguimiento , Lípidos/sangreRESUMEN
Carbon aerogels (CAs) have garnered significant attention due to their multifunctional applications. Biomass waste, abundantly generated by agriculture and industry, serves as a primary carbon source. However, developing a facile, sustainable, and efficient method to produce CAs from biomass waste remains challenging. In this study, a one-step Zn2+ ion-glue-assisted carbonization technique was developed to produce large-scale, high-performance CAs. Various biomass materials (wood bits, peanut shells, bamboo bits, and straw waste) were treated in a molten salt system (ZnCl2/KCl) at 300 °C for 2â h to obtain large-block CAs derived from biomass bits. Zn2+ ions cleave cellulose hydrogen bonds in natural biomass, facilitating the dehydration crosslinking reaction among cellulose, hemicellulose, and lignin, thus reconstructing the entire block structure. The resulting CAs exhibited high porosity (95 %) and low density (0.078â g/cm3). Numerous hydroxyl and carbonyl groups were preserved during the low-temperature treatment, facilitating chemical modification for diverse applications. For instance, amidoxime functionalized CAs were utilized as filters for selective and highly efficient extraction of U(VI) from wastewater. The adsorption capacity and extraction efficiency reached 801.2â mg/g and 95 % with a flux rate of 6.1×103â L/m2 â h.
RESUMEN
BACKGROUND: Short-term exposure to ambient air pollution has been linked with daily hospitalization and mortality from acute coronary syndrome (ACS); however, the associations of subdaily (hourly) levels of criteria air pollutants with the onset of ACS and its subtypes have rarely been evaluated. METHODS: We conducted a time-stratified case-crossover study among 1 292 880 patients with ACS from 2239 hospitals in 318 Chinese cities between January 1, 2015, and September 30, 2020. Hourly concentrations of fine particulate matter (PM2.5), coarse particulate matter (PM2.5-10), nitrogen dioxide (NO2), sulfur dioxide (SO2), carbon monoxide (CO), and ozone (O3) were collected. Hourly onset data of ACS and its subtypes, including ST-segment-elevation myocardial infarction, non-ST-segment-elevation myocardial infarction, and unstable angina, were also obtained. Conditional logistic regressions combined with polynomial distributed lag models were applied. RESULTS: Acute exposures to PM2.5, NO2, SO2, and CO were each associated with the onset of ACS and its subtypes. These associations were strongest in the concurrent hour of exposure and were attenuated thereafter, with the weakest effects observed after 15 to 29 hours. There were no apparent thresholds in the concentration-response curves. An interquartile range increase in concentrations of PM2.5 (36.0 µg/m3), NO2 (29.0 µg/m3), SO2 (9.0 µg/m3), and CO (0.6 mg/m3) over the 0 to 24 hours before onset was significantly associated with 1.32%, 3.89%, 0.67%, and 1.55% higher risks of ACS onset, respectively. For a given pollutant, the associations were comparable in magnitude across different subtypes of ACS. NO2 showed the strongest associations with all 3 subtypes, followed by PM2.5, CO, and SO2. Greater magnitude of associations was observed among patients older than 65 years and in the cold season. Null associations of exposure to either PM2.5-10 or O3 with ACS onset were observed. CONCLUSIONS: The results suggest that transient exposure to the air pollutants PM2.5, NO2, SO2, or CO, but not PM2.5-10 or O3, may trigger the onset of ACS, even at concentrations below the World Health Organization air quality guidelines.
Asunto(s)
Síndrome Coronario Agudo , Contaminantes Atmosféricos , Contaminación del Aire , Exposición a Riesgos Ambientales , Síndrome Coronario Agudo/epidemiología , Contaminantes Atmosféricos/análisis , Contaminantes Atmosféricos/toxicidad , Contaminación del Aire/efectos adversos , Contaminación del Aire/análisis , Monóxido de Carbono/análisis , Monóxido de Carbono/toxicidad , China/epidemiología , Ciudades/epidemiología , Estudios Cruzados , Exposición a Riesgos Ambientales/efectos adversos , Exposición a Riesgos Ambientales/análisis , Humanos , Dióxido de Nitrógeno/análisis , Dióxido de Nitrógeno/toxicidad , Ozono/análisis , Ozono/toxicidad , Material Particulado/análisis , Material Particulado/toxicidad , Dióxido de Azufre/análisis , Dióxido de Azufre/toxicidad , Factores de TiempoRESUMEN
Genomic discovery efforts for hematological traits have been successfully conducted through genome-wide association study on samples of predominantly European ancestry. We sought to conduct unbiased genetic discovery for coding variants that influence hematological traits in a Han Chinese population. A total of 5257 Han Chinese subjects from Beijing, China were included in the discovery cohort and analyzed by an Illumina ExomeChip array. Replication analyses were conducted in 3827 independent Chinese subjects. We analyzed 12 hematological traits and identified 22 exome-wide significant single-nucleotide polymorphisms (SNP)-trait associations with 15 independent SNPs. Our study provides replication for two associations previously reported but not replicated. Further, one association was identified and replicated in the current study, of a coding variant in the myeloproliferative leukemia (MPL) gene, c.793C > T, p.Leu265Phe (L265F) with increased platelet count (ß = 20.6 109 cells/l, Pmeta-analysis = 2.6 × 10-13). This variant is observed at ~2% population frequency in East Asians, whereas it has not been reported in gnomAD European or African populations. Functional analysis demonstrated that expression of MPL L265F in Ba/F3 cells resulted in enhanced phosphorylation of Stat3 and ERK1/2 as compared with the reference MPL allele, supporting altered activation of the JAK-STAT signal transduction pathway as the mechanism underlying the novel association between MPL L265F and platelet count.
Asunto(s)
Estudio de Asociación del Genoma Completo , Pueblo Asiatico/genética , Humanos , Recuento de Plaquetas , Polimorfismo de Nucleótido Simple/genética , Receptores de Trombopoyetina/genética , Transducción de Señal/genéticaRESUMEN
Background Coronary Artery Disease Reporting and Data System (CAD-RADS) was developed to standardize and optimize disease management in patients after coronary CT angiography (CCTA), but the impact of CAD-RADS management recommendations on clinical outcomes remains unclear. Purpose To retrospectively assess the association between the appropriateness of post-CCTA management according to CAD-RADS version 2.0 and clinical outcomes. Materials and Methods From January 2016 to January 2018, consecutive participants with stable chest pain referred for CCTA were prospectively included in a Chinese registry and followed for 4 years. Retrospectively, CAD-RADS 2.0 classification and the appropriateness of post-CCTA management were determined. Propensity score matching (PSM) was used to adjust for confounding variables. Hazard ratios (HRs) for a major adverse cardiovascular event (MACE), relative risks for invasive coronary angiography (ICA), and the corresponding number needed to treat were estimated. Results Of the 14 232 included participants (mean age, 61 years ± 13 [SD]; 8852 male), 2330, 2756, and 2614 were retrospectively categorized in CAD-RADS 1, 2, and 3, respectively. Only 26% of participants with CAD-RADS 1-2 disease and 20% with CAD-RADS 3 received appropriate post-CCTA management. After PSM, appropriate post-CCTA management was associated with lower risk of MACEs (HR, 0.34; 95% CI: 0.22, 0.51; P < .001), corresponding to a number needed to treat of 21 in CAD-RADS 1-2 but not CAD-RADS 3 (HR, 0.86; 95% CI: 0.49, 1.85; P = .42). Appropriate post-CCTA management was associated with decreased use of ICA in CAD-RADS 1-2 (relative risk, 0.40; 95% CI: 0.29, 0.55; P < .001) and 3 (relative risk, 0.33; 95% CI: 0.28, 0.39; P < .001), resulting in a number needed to treat of 14 and 2, respectively. Conclusion In this retrospective secondary analysis, appropriate disease management after CCTA according to CAD-RADS 2.0 was associated with lower risk of MACEs and more prudent use of ICA. ClinicalTrials.gov registration no. NCT04691037 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Leipsic and Tzimas in this issue.
Asunto(s)
Enfermedad de la Arteria Coronaria , Humanos , Masculino , Persona de Mediana Edad , Dolor en el Pecho/diagnóstico por imagen , Dolor en el Pecho/etiología , Angiografía por Tomografía Computarizada , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Pueblos del Este de Asia , Estudios Retrospectivos , Anciano , Sistema de RegistrosRESUMEN
BACKGROUND: Assessing index of microcirculatory resistance (IMR) is customarily performed using intracoronary wires fitted with sensors by at least 3 intracoronary injections of 3 to 4 mL of room-temperature saline during sustained hyperemia, which is time- and cost-consuming. METHODS: The FLASH IMR study is a prospective, multicenter, randomized study to assess the diagnostic performance of coronary angiography-derived IMR (caIMR) in patients with suspected myocardial ischemia with nonobstructive coronary arteries using wire-based IMR as a reference. The caIMR was calculated by an optimized computational fluid dynamics model simulating hemodynamics during diastole based on coronary angiograms. TIMI frame count and aortic pressure were included in computation. caIMR was determined onsite in real time and compared blind to wire-based IMR by an independent core laboratory, using wire-based IMR ≥25 units as indicative of abnormal coronary microcirculatory resistance. The primary endpoint was the diagnostic accuracy of caIMR, using wire-based IMR as a reference, with a pre-specified performance goal of 82%. RESULTS: A total of 113 patients underwent paired caIMR and wire-based IMR measurements. Order of performance of tests was based on randomization. Diagnostic accuracy, sensitivity, specificity, positive and negative predictive values of caIMR were 93.8% (95% CI: 87.7%-97.5%), 95.1% (95% CI: 83.5%- 99.4%), 93.1% (95% CI: 84.5%-97.7%), 88.6% (95% CI: 75.4%-96.2%) and 97.1% (95% CI: 89.9%-99.7%). The receiver-operating curve for caIMR to diagnose abnormal coronary microcirculatory resistance had area under the curve of 0.963 (95% CI: 0.928-0.999). CONCLUSIONS: Angiography-based caIMR has a good diagnostic yield with wire-based IMR. GOV IDENTIFIER: NCT05009667.
Asunto(s)
Enfermedad de la Arteria Coronaria , Humanos , Angiografía Coronaria , Microcirculación , Estudios Prospectivos , Resistencia Vascular , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Valor Predictivo de las Pruebas , Circulación CoronariaRESUMEN
BACKGROUND: Controversial findings have been reported in the literature regarding the impact of the absence of standard modifiable cardiovascular risk factors (SMuRFs) on long-term mortality risk in patients with acute coronary syndrome (ACS). While the prognostic additive value of SMuRFs has been well described, the prognostic role of prior cardiovascular disease (CVD) by sex is less well-known in patients with and without SMuRFs. METHODS: EPICOR and EPICOR Asia are prospective, observational registries conducted between 2010 and 2014, which enrolled ACS patients in 28 countries across Europe, Latin America, and Asia. Association between SMuRFs (diabetes, dyslipidaemia, hypertension, and smoking) and 2-year postdischarge mortality was evaluated using adjusted Cox models stratified by geographical region. RESULTS: Among 23,489 patients, the mean age was 60.9 ± 11.9 years, 24.3% were women, 4,582 (20.1%) presented without SMuRFs, and 16,055 (69.5%) without prior CVD. Patients with SMuRFs had a higher crude 2-year postdischarge mortality (HR 1.86; 95% CI, 1.56-2.22; P < .001), compared to those without SMuRFs. After adjustment for potential confounding, the association between SMuRFs and 2-year mortality risk was substantially attenuated (HR 1.17, 95% CI 0.98-1.41; P = .087), regardless of the type of ACS. The risk conferred by prior CVD was added to the underlying risk of SMuRFs to provide risk-specific phenotypes (eg, women with SMuRFs and with prior CVD were at higher risk of dying than women without SMuRFs and without CVD; HR 1.67, 95% CI 1.34-2.06). CONCLUSIONS: In this large-scale international ACS cohort the absence of SMuRFs was not associated with a lower adjusted 2-year postdischarge mortality risk. Patients with both SMuRFs and prior CVD had a higher mortality irrespective of their sex.
Asunto(s)
Síndrome Coronario Agudo , Enfermedades Cardiovasculares , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Síndrome Coronario Agudo/complicaciones , Enfermedades Cardiovasculares/complicaciones , Estudios Prospectivos , Cuidados Posteriores , Factores de Riesgo , Alta del Paciente , Factores de Riesgo de Enfermedad CardiacaRESUMEN
The refractive index is a critical parameter in optical and photonic device design. However, due to the lack of available data, precise designs of devices working in low temperatures are still frequently limited. In this work, we have built a homemade spectroscopic ellipsometer (SE) and measured the refractive index of GaAs at a matrix of temperatures (4 K < T < 295 K) and photon wavelengths (700 nm < λ < 1000 nm) with a system error of â¼0.04. We verified the credibility of the SE results by comparing them with afore-reported data at room temperature and with higher precision values measured by vertical GaAs cavity at cryogenic temperatures. This work makes up for the lack of the near-infrared refractive index of GaAs at cryogenic temperatures and provides accurate reference data for semiconductor device design and fabrication.
Asunto(s)
Fotones , Refractometría , Temperatura , SemiconductoresRESUMEN
Fault-tolerant quantum computing based on surface code has emerged as an attractive candidate for practical large-scale quantum computers to achieve robust noise resistance. To achieve universality, magic states preparation is a commonly approach for introducing non-Clifford gates. Here, we present a hardware-efficient and scalable protocol for arbitrary logical state preparation for the rotated surface code, and further experimentally implement it on the Zuchongzhi 2.1 superconducting quantum processor. An average of 0.8983±0.0002 logical fidelity at different logical states with distance three is achieved, taking into account both state preparation and measurement errors. In particular, the logical magic states |A^{π/4}⟩_{L}, |H⟩_{L}, and |T⟩_{L} are prepared nondestructively with logical fidelities of 0.8771±0.0009, 0.9090±0.0009, and 0.8890±0.0010, respectively, which are higher than the state distillation protocol threshold, 0.859 (for H-type magic state) and 0.827 (for T-type magic state). Our work provides a viable and efficient avenue for generating high-fidelity raw logical magic states, which is essential for realizing non-Clifford logical gates in the surface code.