Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Eur Radiol ; 33(10): 7340-7351, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37522898

RESUMEN

OBJECTIVES: To investigate the predictability of synthetic relaxometry for neurodevelopmental outcomes in premature infants and to evaluate whether a combination of relaxation times with clinical variables or qualitative MRI abnormalities improves the predictive performance. METHODS: This retrospective study included 33 premature infants scanned with synthetic MRI near or at term equivalent age. Based on neurodevelopmental assessments at 18-24 months of corrected age, infants were classified into two groups (no/mild disability [n = 23] vs. moderate/severe disability [n = 10]). Clinical and MRI characteristics associated with moderate/severe disability were explored, and combined models incorporating independent predictors were established. Ultimately, the predictability of relaxation times, clinical variables, MRI findings, and a combination of the two were evaluated and compared. The models were internally validated using bootstrap resampling. RESULTS: Prolonged T1-frontal/parietal and T2-parietal periventricular white matter (PVWM), moderate-to-severe white matter abnormality, and bronchopulmonary dysplasia were significantly associated with moderate/severe disability. The overall predictive performance of each T1-frontal/-parietal PVWM model was comparable to that of individual MRI finding and clinical models (AUC = 0.71 and 0.76 vs. 0.73 vs. 0.83, respectively; p > 0.27). The combination of clinical variables and T1-parietal PVWM achieved an AUC of 0.94, sensitivity of 90%, and specificity of 91.3%, outperforming the clinical model alone (p = 0.049). The combination of MRI finding and T1-frontal PVWM yielded AUC of 0.86, marginally outperforming the MRI finding model (p = 0.09). Bootstrap resampling showed that the models were valid. CONCLUSIONS: It is feasible to predict adverse outcomes in premature infants by using early synthetic relaxometry. Combining relaxation time with clinical variables or MRI finding improved prediction. CLINICAL RELEVANCE STATEMENT: Synthetic relaxometry performed during the neonatal period may serve as a biomarker for predicting adverse neurodevelopmental outcomes in premature infants. KEY POINTS: • Synthetic relaxometry based on T1 relaxation time of parietal periventricular white matter showed acceptable performance in predicting adverse outcome with an AUC of 0.76 and an accuracy of 78.8%. • The combination of relaxation time with clinical variables and/or structural MRI abnormalities improved predictive performance of adverse outcomes. • Synthetic relaxometry performed during the neonatal period helps predict adverse neurodevelopmental outcome in premature infants.


Asunto(s)
Encéfalo , Recien Nacido Prematuro , Recién Nacido , Lactante , Humanos , Encéfalo/diagnóstico por imagen , Estudios Retrospectivos , Estudios de Factibilidad , Imagen por Resonancia Magnética
2.
Int J Mol Sci ; 24(9)2023 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-37175665

RESUMEN

Autoimmune neuroinflammatory diseases are a group of disorders resulting from abnormal immune responses in the nervous system, causing inflammation and tissue damage. The interleukin (IL) family of cytokines, especially IL-1, IL-6, and IL-17, plays a critical role in the pathogenesis of these diseases. IL-1 is involved in the activation of immune cells, production of pro-inflammatory cytokines, and promotion of blood-brain barrier breakdown. IL-6 is essential for the differentiation of T cells into Th17 cells and has been implicated in the initiation and progression of neuroinflammation. IL-17 is a potent pro-inflammatory cytokine produced by Th17 cells that plays a crucial role in recruiting immune cells to sites of inflammation. This review summarizes the current understanding of the roles of different interleukins in autoimmune neuroinflammatory diseases, including multiple sclerosis, amyotrophic lateral sclerosis, Alzheimer's disease, neuromyelitis optica, and autoimmune encephalitis, and discusses the potential of targeting ILs as a therapeutic strategy against these diseases. We also highlight the need for further research to better understand the roles of ILs in autoimmune neuroinflammatory diseases and to identify new targets for treating these debilitating diseases.


Asunto(s)
Enfermedades Autoinmunes , Enfermedades Neuroinflamatorias , Humanos , Interleucina-17 , Interleucina-6 , Interleucinas , Inflamación/tratamiento farmacológico , Citocinas , Células Th17 , Interleucina-1/uso terapéutico
3.
Neuroradiology ; 64(2): 381-392, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34382095

RESUMEN

PURPOSE: To validate the use of synthetic magnetic resonance imaging (SyMRI) volumetry by comparing with child-optimized SPM 12 volumetry in 3 T pediatric neuroimaging. METHODS: In total, 106 children aged 4.7-18.7 years who underwent both synthetic and 3D T1-weighted imaging and had no abnormal imaging/neurologic findings were included for the SyMRI vs. SPM T1-only segmentation (SPM T1). Forty of the 106 children who underwent an additional 3D T2-weighted imaging were included for the SyMRI vs. SPM multispectral segmentation (SPM multi). SPM segmentation using an age-appropriate atlas and inverse-transforming template-space intracranial mask was compared with SyMRI segmentation. Volume differences between SyMRI and SPM T1 were plotted against age to evaluate the influence of age on volume difference. RESULTS: Measurements derived from SyMRI and two SPM methods showed excellent agreements and strong correlations except for the CSF volume (CSFV) (intraclass correlation coefficients = 0.87-0.98; r = 0.78-0.96; relative volume difference other than CSFV = 6.8-18.5% [SyMRI vs. SPM T1] and 11.3-22.7% [SyMRI vs. SPM multi]). Dice coefficients of all brain tissues (except CSF) were in the range 0.78-0.91. The Bland-Altman plot and age-related volume difference change suggested that the volume differences between the two methods were influenced by the volume of each brain tissue and subject's age (p < 0.05). CONCLUSION: SyMRI and SPM segmentation results were consistent except for CSFV, which supports routine clinical use of SyMRI-based volumetry in pediatric neuroimaging. However, caution should be taken in the interpretation of the CSF segmentation results.


Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Encéfalo/diagnóstico por imagen , Niño , Humanos , Imagenología Tridimensional , Neuroimagen
4.
Pediatr Radiol ; 52(12): 2401-2412, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35661908

RESUMEN

BACKGROUND: Synthetic MRI is a time-efficient imaging technique that provides both quantitative MRI and contrast-weighted images simultaneously. However, a rather long single scan time can be challenging for children. OBJECTIVE: To evaluate the clinical feasibility of time-saving synthetic MRI protocols adjusted for echo train length and receiver bandwidth in pediatric neuroimaging based on image quality assessment and quantitative data analysis. MATERIALS AND METHODS: In total, we included 33 children ages 1.6-17.4 years who underwent synthetic MRI using three sets of echo train length and receiver bandwidth combinations (echo train length [E]12-bandwidth [B in KHz]22, E16-B22 and E16-B83) at 3 T. The image quality and lesion conspicuity of synthetic contrast-weighted images were compared between the suggested protocol (E12-B22) and adjusted protocols (E16-B22 and E16-B83). We also compared tissue values (T1, T2, proton-density values) and brain volumetry. RESULTS: For the E16-B83 combination, image quality was sufficient except for 15.2% of T1-W and 3% of T2-W fluid-attenuated inversion recovery (FLAIR) images, with remarkable scan time reduction (up to 35%). The E16-B22 combination demonstrated a comparable image quality to E12-B22 (P>0.05) with a scan time reduction of up to 8%. There were no significant differences in lesion conspicuity among the three protocols (P>0.05). Tissue value measurements and brain tissue volumes obtained with the E12-B22 protocol and adjusted protocols showed excellent agreement and strong correlations except for gray matter volume and non-white matter/gray matter/cerebrospinal fluid volume in E12-B22 vs. E16-B83. CONCLUSION: The adjusted synthetic protocols produced image quality sufficient or comparable to that of the suggested protocol while maintaining lesion conspicuity with reduced scan time. The quantitative values were generally consistent with the suggested MRI-protocol-derived values, which supports the clinical application of adjusted protocols in pediatric neuroimaging.


Asunto(s)
Imagen por Resonancia Magnética , Neuroimagen , Humanos , Niño , Lactante , Preescolar , Adolescente , Imagen por Resonancia Magnética/métodos , Neuroimagen/métodos , Encéfalo/diagnóstico por imagen , Cabeza , Proyectos de Investigación
5.
Eur Radiol ; 30(9): 5130-5138, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32333146

RESUMEN

OBJECTIVES: To evaluate the feasibility and image quality of respiratory motion-resolved 4D zero echo time (ZTE) lung MRI compared with that of 3D ZTE. METHODS: Our institutional review board approved this study. Twenty-one patients underwent lung scans using 3D ZTE and 4D ZTE sequences via prospective and retrospective soft gating techniques, respectively. Image qualities of 3D ZTE and 4D ZTE at end-expiration were compared through objective and subjective assessments. The quality of end-expiratory images of 3D ZTE and 4D ZTE of the two groups with different lung functions was also compared. RESULTS: Images were successfully acquired in all patients without any adverse events. Signal-to-noise ratios (SNRs) of lung parenchyma and thoracic structures were significantly (all p < 0.001) higher in 4D ZTE. Contrast-to-noise ratios (CNRs) of peripheral bronchi, peripheral pulmonary vessels, and nodules or masses were significantly (all p < 0.001) higher in 4D ZTE. The subjective image quality assessed by two independent radiologists showed that intrapulmonary structures, noise and artifacts, and overall acceptability were superior in 4D ZTE (all p < 0.001). Image qualities of groups with normal and low lung functions differed significantly (all p < 0.05) in 3D ZTE, but not in 4D ZTE. The mean acquisition time was 136 s (127-143 s) in 3D ZTE and 325 s (308-352 s) in 4D ZTE. CONCLUSIONS: Respiratory motion-resolved 4D ZTE lung imaging was feasible as part of routine chest MRI. The 4D ZTE provides motion-robust lung parenchymal images with better SNR and CNR than the 3D ZTE, regardless of patients' lung function. KEY POINTS: • ZTE MRI captures rapidly decaying transverse magnetization in the lung parenchyma. • 4D ZTE provides motion-robust lung parenchymal images with better SNR and CNR compared with 3D ZTE. • Compared with 3D ZTE, the image quality of 4D ZTE lung MRI was affected less by patients' lung function and respiratory performance.


Asunto(s)
Imagenología Tridimensional/métodos , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Adulto , Anciano , Anciano de 80 o más Años , Artefactos , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Movimiento (Física) , Estudios Prospectivos , Respiración , Estudios Retrospectivos , Relación Señal-Ruido , Tórax/diagnóstico por imagen , Adulto Joven
6.
Eur Radiol ; 29(5): 2253-2262, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30547204

RESUMEN

OBJECTIVE: To determine the feasibility of using high-resolution volumetric zero echo time (ZTE) sequence in routine lung magnetic resonance imaging (MRI) and compare free breathing 3D ultrashort echo time (UTE) and ZTE lung MRI in terms of image quality and small-nodule detection. MATERIALS AND METHODS: Our Institutional Review Board approved this study. Twenty patients underwent both UTE and ZTE sequences during routine lung MR. UTE and ZTE images were compared in terms of subjective image quality and detection of lung parenchymal signal, intrapulmonary structures, and sub-centimeter nodules. Differences between the two sequences were compared through statistical analysis. RESULTS: Lung parenchyma showed significantly (p < 0.05) higher signal-to-noise ratio (SNR) in ZTE than in UTE. The SNR and contrast-to-noise ratio (CNR) of peripheral bronchus and small pulmonary arteries were significantly (all p < 0.05) higher in ZTE. Subjective image quality evaluated by two independent radiologists in terms of depicting normal structures and overall acceptability was superior in ZTE (p < 0.05). The diagnostic accuracy for sub-centimeter nodules was significantly higher for ZTE (reader 1: AUC, 0.972; p = 0.044; reader 2: AUC, 0.946; p = 0.045) than that for UTE (reader 1: AUC, 0.885; reader 2: AUC, 0.855). Mean scan time was 131 s (125-141 s) in ZTE and 467 s (453-508 s) in UTE. ZTE images were obtained with less acoustic noise. CONCLUSION: Implementing ZTE as an additional sequence in routine lung MR is feasible. ZTE can provide high-resolution pulmonary structural information with better SNR and CNR using shorter time than UTE. KEY POINTS: • Both UTE and ZTE techniques use very short TEs to capture signals from very short T2/T2* tissues. • ZTE is superior in capturing lung parenchymal signal than UTE. • ZTE provides high-resolution structural information with better SNR and CNR for normal intrapulmonary structures and small nodules using shorter scan time than UTE.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Respiración , Relación Señal-Ruido , Adulto Joven
7.
Pediatr Radiol ; 47(12): 1638-1647, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28638982

RESUMEN

BACKGROUND: The clinical application of the multi-echo, multi-delay technique of synthetic magnetic resonance imaging (MRI) generates multiple sequences in a single acquisition but has mainly been used in adults. OBJECTIVE: To evaluate the image quality of synthetic brain MR in children compared with that of conventional images. MATERIALS AND METHODS: Twenty-nine children (median age: 6 years, range: 0-16 years) underwent synthetic and conventional imaging. Synthetic (T2-weighted, T1-weighted and fluid-attenuated inversion recovery [FLAIR]) images with settings matching those of the conventional images were generated. The overall image quality, gray/white matter differentiation, lesion conspicuity and image degradations were rated on a 5-point scale. The relative contrasts were assessed quantitatively and acquisition times for the two imaging techniques were compared. RESULTS: Synthetic images were inferior due to more pronounced image degradations; however, there were no significant differences for T1- and T2-weighted images in children <2 years old. The quality of T1- and T2-weighted images were within the diagnostically acceptable range. FLAIR images showed greatly reduced quality. Gray/white matter differentiation was comparable or better in synthetic T1- and T2-weighted images, but poorer in FLAIR images. There was no effect on lesion conspicuity. Synthetic images had equal or greater relative contrast. Acquisition time was approximately two-thirds of that for conventional sequences. CONCLUSION: Synthetic T1- and T2-weighted images were diagnostically acceptable, but synthetic FLAIR images were not. Lesion conspicuity and gray/white matter differentiation were comparable to conventional MRI.


Asunto(s)
Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Adolescente , Niño , Preescolar , Femenino , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Lactante , Recién Nacido , Masculino , Estudios Prospectivos
8.
BMC Psychiatry ; 15: 295, 2015 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-26581193

RESUMEN

BACKGROUND: Findings about sex differences in the field of fear conditioning and fear extinction have been mixed. At the psychophysiological level, sex differences emerge only when taking estradiol levels of women into consideration. This suggests that this hormone may also influence sex differences with regards to activations of brain regions involved in fear conditioning and its extinction. Importantly, the neurobiological correlates associated with the use of hormonal oral contraceptives in women have not been fully contrasted against men and against naturally cycling women with different levels of estradiol. In this study, we begin to fill these scientific gaps. METHODS: We recruited 37 healthy men and 48 healthy women. Of these women, 16 were using oral contraceptives (OC) and 32 were naturally cycling. For these naturally cycling women, a median split was performed on their serum estradiol levels to create a high estradiol (HE) group (n = 16) and a low estradiol (LE) group (n = 16). All participants underwent a 2-day fear conditioning and extinction paradigm in a 3 T MR scanner. Using the 4 groups (men, HE women, LE women, and OC users) and controlling for age and coil type, one-way ANCOVAs were performed to look at significant activations within the nodes of the fear circuit. Using post-hoc analyses, beta-weights were extracted in brain regions showing significant effects in order to unveil the differences based on hormonal status (men, HE, LE, OC). RESULTS: Significant main effect of hormonal status group was found across the different phases of the experiment and in different sub-regions of the insular and cingulate cortices, amygdala, hippocampus, and hypothalamus. During conditioning, extinction and recall, most of the observed differences suggested higher activations among HE women relative to men. During the unconditioned response, however, a different pattern was observed with men showing significantly higher brain activations. CONCLUSIONS: Our data further support the important contribution of estradiol levels in the activation of brain regions underlying fear learning and extinction. The results highlight the need to document gonadal hormonal levels, menstrual cycle phase as well as oral contraceptive use in women in order to avoid overlooking sex differences when investigating the neurobiology of emotional regulation.


Asunto(s)
Anticonceptivos Hormonales Orales/metabolismo , Estradiol/metabolismo , Extinción Psicológica/fisiología , Miedo/fisiología , Caracteres Sexuales , Adulto , Amígdala del Cerebelo/metabolismo , Reacción de Prevención , Encéfalo/fisiología , Miedo/psicología , Femenino , Giro del Cíngulo/metabolismo , Humanos , Masculino , Recuerdo Mental/fisiología , Adulto Joven
9.
Sci Rep ; 14(1): 3864, 2024 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-38366042

RESUMEN

We aimed to evaluate the feasibility of MR elastography (MRE) using a transpelvic approach. Thirty-one patients who underwent prostate MRE and had a pathological diagnosis were included in this study. MRE was obtained using a passive driver placed at the umbilicus and iliac crests. The shear stiffness, clinical data, and conventional imaging findings of prostate cancer and benign prostatic hyperplasia (BPH) were compared. Inter-reader agreements were evaluated using the intraclass coefficient class (ICC). Prostate MRE was successfully performed for all patients (100% technical success rate). Nineteen cancer and 10 BPH lesions were visualized on MRE. The mean shear stiffness of cancer was significantly higher than that of BPH (5.99 ± 1.46 kPa vs. 4.67 ± 1.54 kPa, p = 0.045). One cancer was detected on MRE but not on conventional sequences. Six tiny cancer lesions were not visualized on MRE. The mean size of cancers that were not detected on MRE was smaller than that of cancers that were visible on MRE (0.8 ± 0.3 cm vs. 2.3 ± 1.8 cm, p = 0.001). The inter-reader agreement for interpreting MRE was excellent (ICC = 0.95). Prostate MRE with transpelvic vibration is feasible without intracavitary actuators. Transpelvic prostate MRE is reliable for detecting focal lesions, including clinically significant prostate cancer and BPH.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Hiperplasia Prostática , Neoplasias de la Próstata , Masculino , Humanos , Próstata/diagnóstico por imagen , Vibración , Diagnóstico por Imagen de Elasticidad/métodos , Estudios de Factibilidad , Hiperplasia Prostática/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico por imagen , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/métodos
10.
Diagnostics (Basel) ; 12(1)2022 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-35054316

RESUMEN

(1) Background: Highly flexible adaptive image receive (AIR) coil has become available for clinical use. The present study aimed to evaluate the performance of AIR anterior array coil in lung MR imaging using a zero echo time (ZTE) sequence compared with conventional anterior array (CAA) coil. (2) Methods: Sixty-six patients who underwent lung MR imaging using both AIR coil (ZTE-AIR) and CAA coil (ZTE-CAA) were enrolled. Image quality of ZTE-AIR and ZTE-CAA was quantified by calculating blur metric value, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of lung parenchyma. Image quality was qualitatively assessed by two independent radiologists. Lesion detection capabilities for lung nodules and emphysema and/or lung cysts were evaluated. Patients' comfort levels during examinations were assessed. (3) Results: SNR and CNR of lung parenchyma were higher (both p < 0.001) in ZTE-AIR than in ZTE-CAA. Image sharpness was superior in ZTE-AIR (p < 0.001). Subjective image quality assessed by two independent readers was superior (all p < 0.05) in ZTE-AIR. AIR coil was preferred by 64 of 66 patients. ZTE-AIR showed higher (all p < 0.05) sensitivity for sub-centimeter nodules than ZTE-CAA by both readers. ZTE-AIR showed higher (all p < 0.05) sensitivity and accuracy for detecting emphysema and/or cysts than ZTE-CAA by both readers. (4) Conclusions: The use of highly flexible AIR coil in ZTE lung MR imaging can improve image quality and patient comfort. Application of AIR coil in parenchymal imaging has potential for improving delineation of low-density parenchymal lesions and tiny nodules.

11.
Clin Psychopharmacol Neurosci ; 20(3): 415-426, 2022 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-35879026

RESUMEN

Objective: Recent studies highlighted the triple-network model which illustrated the interactions among three large-scale networks including salience network (SN). The functional magnetic resonance imaging used in this study was designed to investigate the characteristics of three large-scale networks associated with the thought-action fusion (TAF) in patients with obsessive-compulsive disorder (OCD) using power spectral density (PSD) analysis. Methods: This study included 32 OCD patients and 38 age-matched healthy controls (HC). The TAF task was modified from the experiment of Rassin. PSD from time courses in large-scale networks of each subject was measured to compare between the groups for both TAF and resting state. Results: In SN, OCD reported lower power in the low-frequency domain of SN compared to HC using the two-sample t test during the TAF task (t = -2.395, p = 0.019) but not in the resting state. The PSD in the low-frequency domain of the SN had a significant negative correlation with state score in the guilty inventory (r = -0.361, p = 0.042) in OCD patients. Conclusion: This study suggests that OCD patients showed reduced SN power which can be prominent in a certain situation, such as TAF. In addition, the PSD alterations in SN cause difficulty in processing ambiguous emotional cues in social situations, and the difficulty can be connected with a negative feeling (e.g., guilt).

12.
Food Sci Biotechnol ; 29(8): 1101-1112, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32670664

RESUMEN

Black ginseng (BG), which is produced by repeated steaming and drying of fresh ginseng, has various pharmacological and therapeutic properties. This study investigated the anti-hyperglycemic and hypolipidemic effects of BG ethanolic extract in type 2 diabetic db/db mice. The levels of fasting blood glucose, HbA1c, insulin levels and thiobarbituric acid reactive substances values were decreased in the groups fed BG extract (BG) (100 and 900 mg/kg BW/day), compared to the control group (CON). In the BG compared with the CON, hepatic steatosis in the liver and the size of adipocytes in muscle tissue were improved. The administration of BG regulated the glucose transporter type (GLUT) 4 and 2, and peroxisome proliferator-activated receptor (PPAR) α and γ in muscle and liver. Moreover, ginsenosides (Rh4, Rg5, and Rk1), which profiled by HPLC, regulated the markers for lipid metabolism and glucose metabolism; PPARs and GLUTs in muscle and C2C12 rather than liver cells and tissue. These findings suggested that ginsenosides (Rh4, Rg5, and Rk1) from BG extract can ameliorate type 2 diabetes through their anti-hyperglycemic and hypolipidemic effects.

13.
Food Chem ; 297: 124977, 2019 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-31253260

RESUMEN

Polycyclic aromatic hydrocarbons (PAHs) are primarily produced during the incomplete combustion of organic matter. PAHs are suspected endocrine disruptors and possible carcinogenic materials. The major sources of human exposure to PAHs are inhaled fumes and food. The aim of this study was to provide an alternative drying method to mitigate PAH formation in dried red peppers. We prepared dried red pepper samples using air-drying and heat pump-assisted drying methods, and measured the concentrations of four PAHs (PAH4), benzo[a] anthracene (B[a]A), chrysene (CHR), benzo[b]fluoranthene (B[b]F), and benzo[a]pyrene (B[a]P), in the resulting pepper samples. The PAH concentrations ranged from 3.61 to 18.0 µg/kg and from 2.22 to 8.35 µg/kg in the air-dried and heat pump-dried pepper samples, respectively. Overall, the results have shown that dried peppers contain PAH4, that the drying conditions for these contaminants should be optimized for mitigating the PAH formation in dried red peppers.


Asunto(s)
Capsicum/química , Hidrocarburos Policíclicos Aromáticos/metabolismo , Antracenos/análisis , Antracenos/metabolismo , Benzo(a)pireno/análisis , Benzo(a)pireno/metabolismo , Carcinógenos/análisis , Carcinógenos/metabolismo , Crisenos/análisis , Crisenos/metabolismo , Desecación , Fluorenos/análisis , Fluorenos/metabolismo , Calor , Hidrocarburos Policíclicos Aromáticos/análisis
14.
J Neurol ; 266(2): 431-439, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30536110

RESUMEN

BACKGROUND: Ultrafast brain MRI is required for uncooperative patients and time-critical diseases such as stroke because it reduces scan times and motion artifacts. This study investigated the clinical feasibility of a 1-min ultrafast brain MRI protocol for detecting intracranial abnormalities in restless and uncooperative patients. METHODS: We retrospectively reviewed the records of 25 patients who underwent a 1-min ultrafast MRI protocol using T1-weighted image, T2-weighted image, echo-planar fluid-attenuated inversion recovery, diffusion-weighted image, and T2*-weighted image between March 2017 and May 2017. Simple methods were applied for ultrafast MRI protocol to reduce scan time as follows: parallel imaging techniques, multiband technique on diffusion sequence, and echo-planar fluid-attenuated inversion recovery. The images were compared with the routine brain MRI protocol using synthetic MRI, and quality was assessed by two independent readers. The Wilcoxon signed-rank test was used to compare the readers' ratings of the routine MRI protocol and ultrafast MRI protocol images. RESULTS: Using a four-point assessment scale, overall image quality and anatomical delineation of ultrafast brain MRI images were lower than those of routine brain MRI images. However, the ultrafast protocol demonstrated sufficient overall image quality and anatomical delineation with an assessment rating greater than two points. The ultrafast protocol had fewer artifacts than the routine protocol using synthetic MRI. CONCLUSIONS: Although the overall image quality and anatomical delineation of the 1-min ultrafast MRI were inferior to those of the routine brain MRI protocol, the ultrafast protocol showed at least sufficient image quality. Therefore, this protocol may be an option in specific clinical situations involving non-cooperative, restless, or pediatric patients, or patients with time-critical disease such as stroke. Further study is required to validate our findings.


Asunto(s)
Encefalopatías/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Neuroimagen/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Protocolos Clínicos , Estudios de Factibilidad , Femenino , Humanos , Imagen por Resonancia Magnética/normas , Masculino , Persona de Mediana Edad , Neuroimagen/normas , Proyectos Piloto , Estudios Retrospectivos , Factores de Tiempo , Adulto Joven
15.
Korean J Radiol ; 17(6): 903-911, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27833406

RESUMEN

OBJECTIVE: To investigate the interobserver and test-retest reproducibility of T1ρ and T2 measurements of lumbar intervertebral discs using 3T magnetic resonance imaging (MRI). MATERIALS AND METHODS: This study included a total of 51 volunteers (female, 26; male, 25; mean age, 54 ± 16.3 years) who underwent lumbar spine MRI with a 3.0 T scanner. Amongst these subjects, 40 underwent repeat T1ρ and T2 measurement acquisitions with identical image protocol. Two observers independently performed the region of interest measurements in the nuclei pulposi of the discs from L1-2 through L5-S1 levels. Statistical analysis was performed using intraclass correlation coefficient (ICC) with a two-way random model of absolute agreement. Comparison of the ICC values was done after acquisition of ICC values using Z test. Statistical significance was defined as p value < 0.05. RESULTS: The ICCs of interobserver reproducibility were 0.951 and 0.672 for T1ρ and T2 mapping, respectively. The ICCs of test-retest reproducibility (40 subjects) for T1ρ and T2 measurements were 0.922 and 0.617 for observer A and 0.914 and 0.628 for observer B, respectively. In the comparison of the aforementioned ICCs, ICCs of interobserver and test-retest reproducibility for T1ρ mapping were significantly higher than T2 mapping (p < 0.001). CONCLUSION: The interobserver and test-retest reproducibility of T1ρ mapping were significantly higher than those of T2 mapping for the quantitative assessment of nuclei pulposi of lumbar intervertebral discs.


Asunto(s)
Degeneración del Disco Intervertebral/diagnóstico , Imagen por Resonancia Magnética , Adulto , Anciano , Femenino , Humanos , Disco Intervertebral/diagnóstico por imagen , Degeneración del Disco Intervertebral/diagnóstico por imagen , Degeneración del Disco Intervertebral/patología , Vértebras Lumbares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Núcleo Pulposo/diagnóstico por imagen , Estudios Prospectivos , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad
16.
Neuroreport ; 15(11): 1699-703, 2004 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-15257130

RESUMEN

Diffusion tensor imaging is a new in vivo tool not only for the assessment of white matter structural integrity but also for diagnosis and assessment of disease conditions which disturb tissue structural coherence. In this study, we investigated the integrity of auditory pathway in patients of sensorineural hearing loss by means of fractional anisotropy of water diffusion to see any subtle changes of auditory pathways resulting from sensorineural hearing loss. In addition, this study suggests that the diffusion anisotropy measured by diffusion tensor imaging is highly sensitive to otherwise subtle disease processes not normally seen with conventional magnetic resonance imaging or computed tomography contrast.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Pérdida Auditiva Sensorineural/metabolismo , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Enfermedades Auditivas Centrales/metabolismo , Vías Auditivas/metabolismo , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad
17.
J Magn Reson Imaging ; 25(4): 862-5, 2007 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-17335009

RESUMEN

PURPOSE: To evaluate the effect of incidental magnetization transfer (iMT) in multislice brain imaging at 3.0T. MATERIALS AND METHODS: The contribution of iMT to multislice brain MRI was evaluated at 3.0T. In 10 normal subjects we obtained multislice fast spin-echo (FSE) MR images using a 16-echo pulse train without an off-resonance MT pulse at 3.0T and 1.5T. We quantified the extent of iMT by calculating the iMT ratio (iMTR). RESULTS: We found that the iMT contrast (iMTC) has a greater effect at 3.0T. As the number of slices increased in multislice FSE imaging, the difference between two field strengths became larger. Compared to WM structures, however, the difference in iMT effect between 1.5T and 3.0T was smaller in the case of GM structures. CONCLUSION: The iMTC has a greater effect at 3.0T. The strength of the iMT is different for different tissue types and also varies according to the number of slices used.


Asunto(s)
Encéfalo/anatomía & histología , Imagen por Resonancia Magnética/métodos , Adulto , Femenino , Humanos , Masculino , Procesamiento de Señales Asistido por Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA