Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Int J Mol Sci ; 24(14)2023 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-37511192

RESUMEN

Assessment of the quality and current performance of computed tomography (CT) radiomics-based models in predicting epidermal growth factor receptor (EGFR) mutation status in patients with non-small-cell lung carcinoma (NSCLC). Two medical literature databases were systematically searched, and articles presenting original studies on CT radiomics-based models for predicting EGFR mutation status were retrieved. Forest plots and related statistical tests were performed to summarize the model performance and inter-study heterogeneity. The methodological quality of the selected studies was assessed via the Radiomics Quality Score (RQS). The performance of the models was evaluated using the area under the curve (ROC AUC). The range of the Risk RQS across the selected articles varied from 11 to 24, indicating a notable heterogeneity in the quality and methodology of the included studies. The average score was 15.25, which accounted for 42.34% of the maximum possible score. The pooled Area Under the Curve (AUC) value was 0.801, indicating the accuracy of CT radiomics-based models in predicting the EGFR mutation status. CT radiomics-based models show promising results as non-invasive alternatives for predicting EGFR mutation status in NSCLC patients. However, the quality of the studies using CT radiomics-based models varies widely, and further harmonization and prospective validation are needed before the generalization of these models.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Tomografía Computarizada por Rayos X , Humanos , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/genética , Carcinoma de Pulmón de Células no Pequeñas/patología , Receptores ErbB/genética , Interpretación de Imagen Asistida por Computador , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/patología , Mutación , Tomografía Computarizada por Rayos X/métodos
2.
Eur Radiol ; 32(2): 783-792, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34363133

RESUMEN

OBJECTIVE: We studied the repeatability and the relative intra-scan variability across acquisition protocols in CT using phantom and unenhanced abdominal series. METHODS: We used 17 CT scans from the Credence Cartridge Radiomics Phantom database and 20 unenhanced multi-site non-pathologic abdominal patient series for which we measured spleen and liver tissues. We performed multiple measurements in extracting 9 radiomics features. We defined a "tandem" as the measurement of a given tissue (or material) by a given radiomics. For each tandem, we assessed the proportion of the variability attributable to repetitions, acquisition protocols, material, or patient. We analyzed the distribution of the intra-scan correlation between pairs of tandems and checked the impact of correlation coefficient greater than 0.90 in comparing paired and unpaired differences. RESULTS: The repeatability of radiomics features depends on the measured material; 56% of tandems were highly repeatable. Histogram-derived radiomics were generally less repeatable. Nearly 60% of relative radiomics measurements had a correlation coefficient higher than 0.90 allowing paired measurements to improve reliability in detecting the difference between two materials. The analysis of liver and spleen tissues showed that measurement variability was negligible with respect to other variabilities. As for phantom data, we found that gray level zone length matrix (GLZLM)-derived radiomics and gray level co-occurrence matrix (GLCM)-derived radiomics were the most correlating features. For these features, relative intra-scan measurements improved the detection of different materials or tissues. CONCLUSIONS: We identified radiomics features for which the intra-scan measurements between tissues are linearly correlated. This property represents an opportunity to improve tissue characterization and inter-site harmonization. KEY POINTS: • The repeatability of radiomics features on CT depends on the measured material or tissue. • Some tandems of radiomics features/tissues are linearly affected by the variability of acquisition protocols on CT. • Relative intra-scan measurements are an opportunity for improving quantitative imaging on CT.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Tomografía Computarizada por Rayos X , Humanos , Fantasmas de Imagen , Cintigrafía , Reproducibilidad de los Resultados
3.
Eur Radiol ; 31(8): 6059-6068, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33459855

RESUMEN

OBJECTIVES: Following the craze for radiomic features (RF), their lack of reliability raised the question of the generalizability of classification models. Inter-site harmonization of images therefore becomes a central issue. We compared RF harmonization processing designed to detect liver diseases in CT images. METHODS: We retrospectively analyzed 76 multi-center portal CT series of non-diseased (NDL) and diseased liver (DL) patients. In each series, we positioned volumes of interest in spleen and liver, then extracted 9 RF (histogram and texture). We evaluated two RF harmonization approaches. First, in each series, we computed the Z-score of liver measurements based on those computed in the spleen. Second, we evaluated the ComBat method according to each imaging center; parameters were computed in the spleen and applied to the liver. We compared RF distributions and classification performances before/after harmonization. We classified NDL versus spleen and versus DL tissues. RESULTS: The RF distributions were all different between liver and spleen (p < 0.05). The Z-score harmonization outperformed for the detection of liver versus spleen: AUC = 93.1% (p < 0.001). For the detection of DL versus NDL, in a case/control setting, we found no differences between the harmonizations: mean AUC = 73.6% (p = 0.49). Using the whole datasets, the performances were improved using ComBat (p = 0.05) AUC = 82.4% and degraded with Z-score AUC = 67.4% (p = 0.008). CONCLUSIONS: Data harmonization requires to first focus on data structuring to not degrade the performances of subsequent classifications. Liver tissue classification after harmonization of spleen-based RF is a promising strategy for improving the detection of DL tissue. KEY POINTS: • Variability of acquisition parameter makes radiomics of CT features non-reproducible. • Data harmonization can help circumvent the inter-site variability of acquisition protocols. • Inter-site harmonization must be carefully implemented and requires designing consistent data sets.


Asunto(s)
Hígado , Tomografía Computarizada por Rayos X , Estudios de Casos y Controles , Humanos , Hígado/diagnóstico por imagen , Reproducibilidad de los Resultados , Estudios Retrospectivos
4.
J Vasc Interv Radiol ; 30(6): 915-917, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30773435

RESUMEN

Percutaneous radiologic gastrostomy (PRG) requires preliminary gastric inflation through a nasogastric tube (NGT) to safely perform gastric puncture. However, in case of pharyngeal or esophageal obstruction, NGT placement may be impossible even with a hydrophilic angiography catheter and wire. This brief report describes percutaneous computed tomography (CT)-guided gastrostomy with a 2-stick approach without nasogastric insufflation in 13 patients. Technical success rate was 100% with a mean of 1.8 punctures ± 1.0 to access the gastric lumen. Traversal of the colon and liver with a 22-gauge needle was necessary in 4 and 1 patients, respectively. There were no major complications. Minor complications occurred in 6 patients (46%). CT-guided percutaneous gastrostomy is technically feasible with minimal morbidity.


Asunto(s)
Gastrostomía/métodos , Radiografía Intervencional/métodos , Tomografía Computarizada por Rayos X , Anciano , Anciano de 80 o más Años , Femenino , Gastrostomía/instrumentación , Humanos , Masculino , Persona de Mediana Edad , Agujas , Punciones , Estudios Retrospectivos , Resultado del Tratamiento
5.
Eur Radiol ; 28(8): 3362-3371, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29476218

RESUMEN

OBJECTIVE: To assess the reliability of ADC measurements in vitro and in cervical lymph nodes of healthy volunteers. METHODS: We used a GE 1.5 T MRI scanner and a first ice-water phantom according to recommendations released by the Quantitative Imaging Biomarker Alliance (QIBA) for assessing ADC against reference values. We analysed the target size effect by using a second phantom made of six inserted spheres with diameters ranging from 10 to 37 mm. Thirteen healthy volunteers were also scanned to assess the inter- and intra-observer reproducibility of volumetric ADC measurements of cervical lymph nodes. RESULTS: On the ice-water phantom, the error in ADC measurements was less than 4.3 %. The spatial bias due to the non-linearity of gradient fields was found to be 24 % at 8 cm from the isocentre. ADC measure reliability decreased when addressing small targets due to partial volume effects (up to 12.8 %). The mean ADC value of cervical lymph nodes was 0.87.10-3 ± 0.12.10-3 mm2/s with a good intra-observer reliability. Inter-observer reproducibility featured a bias of -5.5 % due to segmentation issues. CONCLUSION: ADC is a potentially important imaging biomarker in oncology; however, variability issues preclude its broader adoption. Reliable use of ADC requires technical advances and systematic quality control. KEY POINTS: • ADC is a promising quantitative imaging biomarker. • ADC has a fair inter-reader variability and good intra-reader variability. • Partial volume effect, post-processing software and non-linearity of scanners are limiting factors. • No threshold values for detecting cervical lymph node malignancy can be drawn.


Asunto(s)
Ganglios Linfáticos/anatomía & histología , Adulto , Sesgo , Vértebras Cervicales , Imagen de Difusión por Resonancia Magnética/métodos , Imagen de Difusión por Resonancia Magnética/normas , Femenino , Voluntarios Sanos , Humanos , Vasos Linfáticos , Masculino , Persona de Mediana Edad , Cuello , Fantasmas de Imagen , Estudios Prospectivos , Reproducibilidad de los Resultados , Adulto Joven
7.
Surg Radiol Anat ; 39(4): 393-403, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27637762

RESUMEN

PURPOSE: Muscles have been proved to be a major component in postural regulation during pathological evolution or aging. Particularly, spinopelvic muscles are recruited for compensatory mechanisms such as pelvic retroversion, or knee flexion. Change in muscles' volume could, therefore, be a marker of greater postural degradation. Yet, it is difficult to interpret spinopelvic muscular degradation as there are few reported values for young asymptomatic adults to compare to. The objective was to provide such reference values on spinopelvic muscles. A model predicting the muscular volume from reduced set of MRI segmented images was investigated. METHODS: A total of 23 asymptomatic subjects younger than 24 years old underwent an MRI acquisition from T12 to the knee. Spinopelvic muscles were segmented to obtain an accurate 3D reconstruction, allowing precise computation of muscle's volume. A model computing the volume of muscular groups from less than six MRI segmented slices was investigated. RESULTS: Baseline values have been reported in tables. For all muscles, invariance was found for the shape factor [ratio of volume over (area times length): SD < 0.04] and volume ratio over total volume (SD < 1.2 %). A model computing the muscular volume from a combination of two to five slices has been evaluated. The five-slices model prediction error (in  % of the real volume from 3D reconstruction) ranged from 6 % (knee flexors and extensors and spine flexors) to 11 % (spine extensors). CONCLUSION: Spinopelvic muscles' values for a reference population have been reported. A new model predicting the muscles' volumes from a reduced set of MRI slices is proposed. While this model still needs to be validated on other populations, the current study appears promising for clinical use to determine, quantitatively, the muscular degradation.


Asunto(s)
Músculos Abdominales/anatomía & histología , Músculos Paraespinales/anatomía & histología , Pelvis/anatomía & histología , Adolescente , Adulto , Variación Anatómica , Femenino , Voluntarios Sanos , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Masculino , Modelos Anatómicos , Modelos Teóricos , Estudios Prospectivos , Valores de Referencia , Adulto Joven
8.
Front Oncol ; 13: 988784, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37007064

RESUMEN

Background: In clinical trials with imaging, Blinded Independent Central Review (BICR) with double reads ensures data blinding and reduces bias in drug evaluations. As double reads can cause discrepancies, evaluations require close monitoring which substantially increases clinical trial costs. We sought to document the variability of double reads at baseline, and variabilities across individual readers and lung trials. Material and methods: We retrospectively analyzed data from five BICR clinical trials evaluating 1720 lung cancer patients treated with immunotherapy or targeted therapy. Fifteen radiologists were involved. The variability was analyzed using a set of 71 features derived from tumor selection, measurements, and disease location. We selected a subset of readers that evaluated ≥50 patients in ≥two trials, to compare individual reader's selections. Finally, we evaluated inter-trial homogeneity using a subset of patients for whom both readers assessed the exact same disease locations. Significance level was 0.05. Multiple pair-wise comparisons of continuous variables and proportions were performed using one-way ANOVA and Marascuilo procedure, respectively. Results: Across trials, on average per patient, target lesion (TL) number ranged 1.9 to 3.0, sum of tumor diameter (SOD) 57.1 to 91.9 mm. MeanSOD=83.7 mm. In four trials, MeanSOD of double reads was significantly different. Less than 10% of patients had TLs selected in completely different organs and 43.5% had at least one selected in different organs. Discrepancies in disease locations happened mainly in lymph nodes (20.1%) and bones (12.2%). Discrepancies in measurable disease happened mainly in lung (19.6%). Between individual readers, the MeanSOD and disease selection were significantly different (p<0.001). In inter-trials comparisons, on average per patient, the number of selected TLs ranged 2.1 to 2.8, MeanSOD 61.0 to 92.4 mm. Trials were significantly different in MeanSOD (p<0.0001) and average number of selected TLs (p=0.007). The proportion of patients having one of the top diseases was significantly different only between two trials for lung. Significant differences were observed for all other disease locations (p<0.05). Conclusions: We found significant double read variabilities at baseline, evidence of reading patterns and a means to compare trials. Clinical trial reliability is influenced by the interplay of readers, patients and trial design.

9.
Front Oncol ; 13: 1239570, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37869080

RESUMEN

Background: In lung clinical trials with imaging, blinded independent central review with double reads is recommended to reduce evaluation bias and the Response Evaluation Criteria In Solid Tumor (RECIST) is still widely used. We retrospectively analyzed the inter-reader discrepancies rate over time, the risk factors for discrepancies related to baseline evaluations, and the potential of machine learning to predict inter-reader discrepancies. Materials and methods: We retrospectively analyzed five BICR clinical trials for patients on immunotherapy or targeted therapy for lung cancer. Double reads of 1724 patients involving 17 radiologists were performed using RECIST 1.1. We evaluated the rate of discrepancies over time according to four endpoints: progressive disease declared (PDD), date of progressive disease (DOPD), best overall response (BOR), and date of the first response (DOFR). Risk factors associated with discrepancies were analyzed, two predictive models were evaluated. Results: At the end of trials, the discrepancy rates between trials were not different. On average, the discrepancy rates were 21.0%, 41.0%, 28.8%, and 48.8% for PDD, DOPD, BOR, and DOFR, respectively. Over time, the discrepancy rate was higher for DOFR than DOPD, and the rates increased as the trial progressed, even after accrual was completed. It was rare for readers to not find any disease, for less than 7% of patients, at least one reader selected non-measurable disease only (NTL). Often the readers selected some of their target lesions (TLs) and NTLs in different organs, with ranges of 36.0-57.9% and 60.5-73.5% of patients, respectively. Rarely (4-8.1%) two readers selected all their TLs in different locations. Significant risk factors were different depending on the endpoint and the trial being considered. Prediction had a poor performance but the positive predictive value was higher than 80%. The best classification was obtained with BOR. Conclusion: Predicting discordance rates necessitates having knowledge of patient accrual, patient survival, and the probability of discordances over time. In lung cancer trials, although risk factors for inter-reader discrepancies are known, they are weakly significant, the ability to predict discrepancies from baseline data is limited. To boost prediction accuracy, it would be necessary to enhance baseline-derived features or create new ones, considering other risk factors and looking into optimal reader associations.

10.
Cancer Med ; 12(3): 3112-3122, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36098367

RESUMEN

OBJECTIVE: We compared therapeutic response of Varlitinib + Capecitabine (VC) versus Lapatinib + Capecitabine (LC) in patients with human epidermal growth factor receptor 2-positive metastatic breast cancer after trastuzumab therapy by assessing changes in target lesion (TL) diameter and volume per location. METHODS: We retrospectively analyzed the CT data of the ASLAN001-003 study (NCT02338245). We analyzed TL size and number at each location focusing on therapeutic response from baseline to Week 12. We used TL diameter and volume to conduct an inter-arm comparison of the response according to: RECIST 1.1; stratified per TL location and considering TLs independently. Multiple pairwise intra-arm comparisons of therapeutic responses were performed. Considering TL independently, weighted models were designed by adding weighted mean TL responses grouped by location. RESULTS: We evaluated 42 patients (88 TL) and 35 patients (74 TL), respectively, at baseline and Week 12. We found reductions in breast TL burden in the VC arm compared to the LC arm (p = 0.002 (diameter), p < 0.001 (volume)). Responses and TL sizes at baseline were not correlated. Explained variabilities of volume change per TL location, patient and patient:TL interaction were 36%, 10% and 4% (VC), and 13%, 1% and 23%, (LC). A test of inter-arm difference of responses yielded p = 0.07 (diameter), and p < 0.001 (volume). CONCLUSIONS: The therapeutic responses differed across tumors' locations; the magnitude of the differences of responses across the tumors' locations were drug-dependent. Stratified analysis of the response by tumor location improved drug comparisons and is a powerful tool to understand TL heterogeneity.


Asunto(s)
Neoplasias de la Mama , Humanos , Femenino , Neoplasias de la Mama/patología , Capecitabina/uso terapéutico , Lapatinib , Estudios Retrospectivos , Receptor ErbB-2/metabolismo , Quinazolinas/uso terapéutico , Resultado del Tratamiento , Trastuzumab/uso terapéutico , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico
11.
Insights Imaging ; 12(1): 78, 2021 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-34132919

RESUMEN

Artificial intelligence algorithms are booming in medicine, and the question of biases induced or perpetuated by these tools is a very important topic. There is a greater risk of these biases in radiology, which is now the primary diagnostic tool in modern treatment. Some authors have recently proposed an analysis framework for social inequalities and the biases at risk of being introduced into future algorithms. In our paper, we comment on the different strategies for resolving these biases. We warn that there is an even greater risk in mixing the notion of equity, the definition of which is socio-political, into the design stages of these algorithms. We believe that rather than being beneficial, this could in fact harm the main purpose of these artificial intelligence tools, which is the care of the patient.

12.
Insights Imaging ; 12(1): 36, 2021 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-33738548

RESUMEN

Response Evaluation Criteria In Solid Tumors (RECIST) is still the predominant criteria base for assessing tumor burden in oncology clinical trials. Despite several improvements that followed its first publication, RECIST continues to allow readers a lot of freedom in their evaluations. Notably in the selection of tumors at baseline. This subjectivity is the source of many suboptimal evaluations. When starting a baseline analysis, radiologists cannot always identify tumor malignancy with any certainty. Also, with RECIST, some findings can be deemed equivocal by radiologists with no confirmatory ground truth to rely on. In the specific case of Blinded Independent Central Review clinical trials with double reads using RECIST, the selection of equivocal tumors can have two major consequences: inter-reader variability and modified sensitivity of the therapeutic response. Apart from the main causes leading to the selection of an equivocal lesion, due to the uncertainty of the radiological characteristics or due to the censoring of on-site evaluations, several other situations can be described more precisely. These latter involve cases where an equivocal is selected as target or non-target lesions, the management of equivocal lymph nodes and the case of few target lesions. In all cases, awareness of the impact of selecting a non-malignant lesion will lead radiologists to make selections in the most rational way. Also, in clinical trials where the primary endpoint differs between phase 2 (response-related) and phase 3 (progression-related) trials, our impact analysis will help them to devise strategies for the management of equivocal lesions.

13.
Cancers (Basel) ; 13(18)2021 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-34572761

RESUMEN

BACKGROUND: Double reads in blinded independent central reviews (BICRs) are recommended to control the quality of trials but they are prone to discordances. We analyzed inter-reader discordances in a pool of lung cancer trials using RECIST 1.1. METHODS: We analyzed six lung cancer BICR trials that included 1833 patients (10,684 time points) involving 17 radiologists. We analyzed the rate of discrepancy of each trial at the time-point and patient levels as well as testing inter-trial differences. The analysis of adjudication made it possible to compute the readers' endorsement rates, the root causes of adjudications, and the proportions of "errors" versus "medically justifiable differences". RESULTS: The trials had significantly different discrepancy rates both at the time-point (average = 34.3%) and patient (average = 59.2%) levels. When considering only discrepancies for progressive disease, homogeneous discrepancy rates were found with an average of 32.9%, while readers' endorsement rates ranged between 27.7% and 77.8%. Major causes of adjudication were different per trial, with medically justifiable differences being the most common, triggering 74.2% of total adjudications. CONCLUSIONS: We provide baseline performances for monitoring reader performance in trials with double reads. Intelligent reading system implementation along with appropriate reader training and monitoring are solutions that could mitigate a large portion of the commonly encountered reading errors.

14.
Eur J Radiol ; 129: 109091, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32497944

RESUMEN

PURPOSE: Gaucher disease (GD) is an inherited lysosomal storage disorder. The Vertebral Disk Ratio (VDR) is a semi-quantitative imaging biomarker designed to diagnose and monitor GD. Computed from standard T1 MRI images, the VDR is derived from 2D segmentations. This study aimed to evaluate the 3D version of VDR, namely eVDR, and analyze the performances of two eVDR-derived response criteria for GD patients. METHODS: Three datasets were used: 8 longitudinal GD patients, 13 non-GD patients, and 2 longitudinal GD patients with known Bone Marrow Burden (BMB) scores. Two eVDR-derived response criteria were tested: 1) a parametric version (PeVDR) averaging all eVDR measures recorded for the 5 lumbar vertebrae; and 2) a non-parametric version (NPeVDR), considering all eVDR measures as independent and evaluating therapeutic response in a paired fashion. Analyses included assessment of reader variability in eVDR (3D) versus VDR (2D) and comparison with BMB response criteria. RESULTS: The repeatability of eVDR (3D) versus VDR (2D) demonstrated no difference in mean values but a lower variance (p < 0.004). The PeVDR intra-reader variability had a standard deviation < 0.1 with a coefficient of variation < 5%; the inter-reader variability featured a Limit of Agreement < 5% and a Bias < 3%. Observational comparison of eVDR and BMB scoring and sensitivity indicated a correlation between PeVDR and BMB, with an improved sensitivity with the NPeVDR version. CONCLUSIONS: Based on a standard MRI sequence, the eVDR imaging biomarker and its derived response criteria improved GD assessments and could help assessing other bone marrow diseases.


Asunto(s)
Enfermedad de Gaucher/diagnóstico por imagen , Disco Intervertebral/diagnóstico por imagen , Vértebras Lumbares/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Adulto , Biomarcadores , Conjuntos de Datos como Asunto , Femenino , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos
16.
Ann Palliat Med ; 8(5): 781-785, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31735044

RESUMEN

The status of mental health of physicians practicing in cancer research centers is evaluated. To date little information is given in research to date concerning the burnout syndrome. Recommendations are made for a better psychological development of caregivers.


Asunto(s)
Academias e Institutos , Agotamiento Profesional/psicología , Instituciones Oncológicas/organización & administración , Cuidadores/psicología , Cuerpo Médico de Hospitales/psicología , Neoplasias/terapia , Humanos
17.
Eur Thyroid J ; 8(5): 273-277, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31768339

RESUMEN

INTRODUCTION: Distant metastases of papillary thyroid cancers are rare. Most common metastatic sites include bone and lung, whereas metastases to brain, eye, breast, liver, kidney, muscle, and skin are infrequent and almost always appear in advanced-stage tumor disease. Metastases to ovary and/or uterus are even scarcer. We report herein a very exceptional case of asymptomatic malignant-to-benign tumor-to-tumor metastasis of thyroid origin into a uterine leiomyoma. CASE PRESENTATION: We present the case of a 53-year-old female patient who had a previous history of pT1b N0 M0 R0 papillary carcinoma of the lower left thyroid lobe, treated by total thyroidectomy and central lymph node dissection and two successive administrations of radioactive treatment with iodine-131. Six years later, follow-up imaging disclosed an asymptomatic slow-growing 40-mm-long pedicled subserous heterogeneous uterine myoma including a 12-mm hypervascular nodule, which was suspicious for thyroid malignancy on MRI. DISCUSSION: Histopathology of a hysterectomy specimen disclosed a hypervascular well-limited poorly differentiated trabecular carcinomatous infiltration within the uterine leiomyoma. The immunohistochemical profile of the suspicious nodule was compatible with a thyroid origin. CONCLUSION: A hypervascular "hot spot" intramyoma nodule was the diagnostic clue in a clinical context of hematogenous tumor spread of thyroid origin (increased thyroglobulin level).

18.
Eur J Radiol ; 118: 257-263, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31439252

RESUMEN

PURPOSE: In oncology clinical trials, nonconformity issues are frequently reported. Radiological workload is increasing, thus reducing radiologists' availability and affecting diagnostic quality. We compared performances of a standard radiological workflow (SW) and a novel "hybrid workflow" (HW). METHOD: We prospectively studied imaging data of 40 patients included in RECIST 1.1 clinical trials. Ninety-six time-points were reviewed by 7 radiologists and one trained technologist. Nonconformities using the SW were retrieved from hospital archives. For the HW, radiologists performed all baseline evaluations; the technologist made subsequent measurements. Finally, the radiologists checked the technologist's findings before confirming the evaluations. The HW enabled implementation of an electronic reporting system. An independent body compared SW and HW reading times and nonconformity occurrences. RESULTS: Using SW, 19 types of nonconformity were found: blank report (13%); unsigned report (11%); undocumented change of tumor burden (10%); undocumented new lesions (9%); missing/wrong patients' appointment dates (7%); undocumented tumor location (5%); error in tumor burden change (5%). SW and HW nonconformities affected 55% (179/323) and 5% (2/40) of reports, respectively (p < 0.001). HW nonconformities were: one inaccurate login name was used on the platform, and one erroneous time-point number. On average, SW required 11'30″ [10'06″; 13'20″] per time-point. HW required 1'35″ [40″; 5'08″] for radiologists, and 12'18″ [11'12″; 14'18″] for the technologist. CONCLUSIONS: HW significantly reduced the number of trial nonconformities and saved 87% of radiologists' time while enabling them to apply their expertise to final decisions. HW could offer an effective opportunity for cost reduction associated with improved imaging trial quality.


Asunto(s)
Ensayos Clínicos como Asunto/estadística & datos numéricos , Neoplasias/terapia , Criterios de Evaluación de Respuesta en Tumores Sólidos , Flujo de Trabajo , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neoplasias/patología , Radiólogos/estadística & datos numéricos , Radiología/estadística & datos numéricos , Sistemas de Información Radiológica/estadística & datos numéricos , Factores de Tiempo , Carga Tumoral , Carga de Trabajo/estadística & datos numéricos
19.
Insights Imaging ; 9(4): 599-609, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29770927

RESUMEN

The digitalization of modern imaging has led radiologists to become very familiar with computers and their user interfaces (UI). New options for display and command offer expanded possibilities, but the mouse and keyboard remain the most commonly utilized, for usability reasons. In this work, we review and discuss different UI and their possible application in radiology. We consider two-dimensional and three-dimensional imaging displays in the context of interventional radiology, and discuss interest in touchscreens, kinetic sensors, eye detection, and augmented or virtual reality. We show that UI design specifically for radiologists is key for future use and adoption of such new interfaces. Next-generation UI must fulfil professional needs, while considering contextual constraints. TEACHING POINTS: • The mouse and keyboard remain the most utilized user interfaces for radiologists. • Touchscreen, holographic, kinetic sensors and eye tracking offer new possibilities for interaction. • 3D and 2D imaging require specific user interfaces. • Holographic display and augmented reality provide a third dimension to volume imaging. • Good usability is essential for adoption of new user interfaces by radiologists.

20.
PLoS One ; 13(2): e0192124, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29444120

RESUMEN

OBJECTIVE: The measure of body surface area (BSA) is a standard for planning optimal dosing in oncology. This index is derived from a model having questionable performances. In this study, we proposed measurement of BSA from whole body CT images (iBSA). We tested the reliability of iBSA assessments and simulated the impact of our approach on patient chemotherapy dosage planning. METHODS: We first evaluated accuracy and precision of iBSA in measuring 14 phantom and 11 CT test-retest images.Secondly, we retrospectively analyzed 26 whole body PET-CT scans to evaluate inter-method variability between iBSA and the most used anthropomorphic models, notably the "Du Bois and Du Bois" model. Finally, we simulated the impact on chemotherapy dose planning of capecitabine based on iBSA. RESULTS: Precision and accuracy of iBSA measurement featured a standard deviation of 1.11% and a mean error of 1.53%. Inter-method variability between iBSA and "Du Bois and Du Bois" assessment featured a standard deviation of 4.11% leading to a reclassification rate of capecitabine of 32.5%. CONCLUSIONS: iBSA could help the oncologist in standardizing assessments for chemotherapy planning. iBSA could also be relevant for applications such as comprehensive body composition and provide a sensitive measurement for changes related to nutritional intake or other metabolism.


Asunto(s)
Antropometría , Superficie Corporal , Neoplasias/patología , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Antineoplásicos/administración & dosificación , Capecitabina/administración & dosificación , Relación Dosis-Respuesta a Droga , Femenino , Humanos , Masculino , Persona de Mediana Edad , Imagen Multimodal , Neoplasias/tratamiento farmacológico , Fantasmas de Imagen , Tomografía de Emisión de Positrones , Reproducibilidad de los Resultados , Estudios Retrospectivos , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA