Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Magn Reson Med ; 90(4): 1728-1737, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37350426

RESUMEN

PURPOSE: To improve intraoral transverse loop coil design for high-resolution dental MRI. METHODS: The transverse intraoral loop coil (tLoop) was modified (mtLoop) by overlapping the feed port conductors, bending the posterior section, introducing a parallel plate capacitor, optimizing the insulation thickness, and using it in receive-only mode. In addition, an MR-silent insulation was introduced. The performances of the mtLoop and tLoop coils were compared in terms of sensitivity, image SNR, and eddy currents using electromagnetic simulations and MRI measurements at 3T. RESULTS: The receive-only mode of the mtLoop increases the sensitivity at the apices of the roots, and the overlapped feed port design eliminated signal voids along the incisors. The bent posterior section with the parallel plate capacitor reduced the unwanted signal of the tongue by a factor of 2.3 in the selected region off interest and lowered the eddy currents by 10%. The proposed new coil provided higher SNR by elevenfold and 2.5-fold at the incisors and apices of the molar roots within the selected regions of interest, respectively, in the experiments, as well as improved comfort. Optimal insulation thickness was determined as 1 mm. With the mtLoop, a (250 µm)3 isotropic resolution of the dental arch could be realized using a UTE sequence within 2 min total acquisition time. A T2 -SPACE protocol with (350 µm)2 in-plane resolution was also demonstrated. CONCLUSION: The proposed new coil offers higher SNR at the incisors and apices of the molar roots, less unwanted signals from tongue, lower eddy currents, and improved patient comfort.


Asunto(s)
Imagen por Resonancia Magnética , Ondas de Radio , Humanos , Diseño de Equipo , Fantasmas de Imagen , Imagen por Resonancia Magnética/métodos
2.
Neuroimage ; 251: 118978, 2022 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-35143974

RESUMEN

The mammalian neocortex exhibits a stereotypical laminar organization, with feedforward inputs arriving primarily into layer 4, local computations shaping response selectivity in layers 2/3, and outputs to other brain areas emanating via layers 2/3, 5 and 6. It cannot be assumed a priori that these signatures of laminar differences in neuronal circuitry are reflected in hemodynamic signals that form the basis of functional magnetic resonance imaging (fMRI). Indeed, optical imaging of single-vessel functional responses has highlighted the potential limits of using vascular signals as surrogates for mapping the selectivity of neural responses. Therefore, before fMRI can be employed as an effective tool for studying critical aspects of laminar processing, validation with single-vessel resolution is needed. The primary visual cortex (V1) in cats, with its precise neuronal functional micro-architecture, offers an ideal model system to examine laminar differences in stimulus selectivity across imaging modalities. Here we used cerebral blood volume weighted (wCBV) fMRI to examine if layer-specific orientation-selective responses could be detected in cat V1. We found orientation preference maps organized tangential to the cortical surface that typically extended across depth in a columnar fashion. We then examined arterial dilation and blood velocity responses to identical visual stimuli by using two- and three- photon optical imaging at single-vessel resolution-which provides a measure of the hemodynamic signals with the highest spatial resolution. Both fMRI and optical imaging revealed a consistent laminar response pattern in which orientation selectivity in cortical layer 4 was significantly lower compared to layer 2/3. This systematic change in selectivity across cortical layers has a clear underpinning in neural circuitry, particularly when comparing layer 4 to other cortical layers.


Asunto(s)
Imagen por Resonancia Magnética , Corteza Visual Primaria , Animales , Mapeo Encefálico/métodos , Gatos , Volumen Sanguíneo Cerebral , Humanos , Imagen por Resonancia Magnética/métodos , Mamíferos , Imagen Óptica
3.
Neuroimage ; 250: 118924, 2022 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-35065267

RESUMEN

Understanding the link between the brain activity and behavior is a key challenge in modern neuroscience. Behavioral neuroscience, however, lacks tools to record whole-brain activity in complex behavioral settings. Here we demonstrate that a novel Multi-Band SWeep Imaging with Fourier Transformation (MB-SWIFT) functional magnetic resonance imaging (fMRI) approach enables whole-brain studies in spontaneously behaving head-fixed rats. First, we show anatomically relevant functional parcellation. Second, we show sensory, motor, exploration, and stress-related brain activity in relevant networks during corresponding spontaneous behavior. Third, we show odor-induced activation of olfactory system with high correlation between the fMRI and behavioral responses. We conclude that the applied methodology enables novel behavioral study designs in rodents focusing on tasks, cognition, emotions, physical exercise, and social interaction. Importantly, novel zero echo time and large bandwidth approaches, such as MB-SWIFT, can be applied for human behavioral studies, allowing more freedom as body movement is dramatically less restricting factor.


Asunto(s)
Conducta Animal/fisiología , Mapeo Encefálico/métodos , Encéfalo/fisiología , Imagen por Resonancia Magnética/instrumentación , Animales , Electroencefalografía , Diseño de Equipo , Movimientos de la Cabeza , Ratas , Ratas Sprague-Dawley
4.
Magn Reson Med ; 87(6): 2872-2884, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-34985145

RESUMEN

PURPOSE: To develop a high temporal resolution functional MRI method for tracking repeating events in the brain. METHODS: We developed a novel functional MRI method using multiband sweep imaging with Fourier transformation (SWIFT), termed event-recurring SWIFT (EVER-SWIFT). The method is able to image similar repeating events with subsecond temporal resolution. Here, we demonstrate the use of EVER-SWIFT for detecting functional MRI responses during deep brain stimulation of the medial septal nucleus and during spontaneous isoflurane-induced burst suppression in the rat brain at 9.4 T with 200-ms temporal resolution. RESULTS: The EVER-SWIFT approach showed that the shapes and time-to-peak values of the response curves to deep brain stimulation significantly differed between downstream brain regions connected to the medial septal nucleus, resembling findings obtained with traditional 2-second temporal resolution. In contrast, EVER-SWIFT allowed for detailed temporal measurement of a spontaneous isoflurane-induced bursting activity pattern, which was not achieved with traditional temporal resolution. CONCLUSION: The EVER-SWIFT technique enables subsecond 3D imaging of both stimulated and spontaneously recurring brain activities, and thus holds great potential for studying the mechanisms of neuromodulation and spontaneous brain activity.


Asunto(s)
Estimulación Encefálica Profunda , Isoflurano , Animales , Encéfalo/diagnóstico por imagen , Encéfalo/fisiología , Isoflurano/farmacología , Imagen por Resonancia Magnética/métodos , Ratas
5.
Magn Reson Med ; 85(2): 831-844, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32892400

RESUMEN

PURPOSE: We demonstrate the feasibility of MRI with missing-pulse steady-state free precession (MP-SSFP) in a 4T magnet with artificially degraded homogeneity. METHODS: T1 , T2 , and diffusion contrast of MP-SSFP was simulated with constant and alternate radiofrequency (RF) phase using an extended phase graph. To validate MP-SSFP performance in human brain imaging, MP-SSFP was tested with two types of artificially introduced inhomogeneous magnetic fields: (1) a pure linear gradient field, and (2) a pseudo-linear gradient field introduced by mounting a head-gradient set at 36 cm from the magnet isocenter. Image distortion induced by the nonlinear inhomogeneous field was corrected using B0 mapping measured with MP-SSFP. RESULTS: The maximum flip angle in MP-SSFP was limited to ≤10° because of the large range of resonance frequencies in the inhomogeneous magnetic fields tested in this study. Under this flip-angle limitation, MP-SSFP with constant RF phase provided advantages of higher signal-to-noise ratio and insensitivity to B1+ field inhomogeneity as compared with an alternate RF phase. In diffusion simulation, the steady-state magnetization in constant RF phase MP-SSFP increased with an increase of static field gradient up to 8 to 21 mT/m depending on simulation parameters. Experimental results at 4T validated these findings. In human brain imaging, MP-SSFP preserved sufficient signal intensities, but images showed severe image distortion from the pseudo-linear inhomogeneous field. However, following distortion correction, good-quality brain images were achieved. CONCLUSION: MP-SSFP appears to be a feasible MRI technique for brain imaging in an inhomogeneous magnetic field.


Asunto(s)
Campos Magnéticos , Imagen por Resonancia Magnética , Encéfalo/diagnóstico por imagen , Humanos , Ondas de Radio , Relación Señal-Ruido
6.
Neuroimage ; 206: 116338, 2020 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-31730923

RESUMEN

Functional magnetic resonance imaging (fMRI) studies in animal models provide invaluable information regarding normal and abnormal brain function, especially when combined with complementary stimulation and recording techniques. The echo planar imaging (EPI) pulse sequence is the most common choice for fMRI investigations, but it has several shortcomings. EPI is one of the loudest sequences and very prone to movement and susceptibility-induced artefacts, making it suboptimal for awake imaging. Additionally, the fast gradient-switching of EPI induces disrupting currents in simultaneous electrophysiological recordings. Therefore, we investigated whether the unique features of Multi-Band SWeep Imaging with Fourier Transformation (MB-SWIFT) overcome these issues at a high 9.4 T magnetic field, making it a potential alternative to EPI. MB-SWIFT had 32-dB and 20-dB lower peak and average sound pressure levels, respectively, than EPI with typical fMRI parameters. Body movements had little to no effect on MB-SWIFT images or functional connectivity analyses, whereas they severely affected EPI data. The minimal gradient steps of MB-SWIFT induced significantly lower currents in simultaneous electrophysiological recordings than EPI, and there were no electrode-induced distortions in MB-SWIFT images. An independent component analysis of the awake rat functional connectivity data obtained with MB-SWIFT resulted in near whole-brain level functional parcellation, and simultaneous electrophysiological and fMRI measurements in isoflurane-anesthetized rats indicated that MB-SWIFT signal is tightly linked to neuronal resting-state activity. Therefore, we conclude that the MB-SWIFT sequence is a robust preclinical brain mapping tool that can overcome many of the drawbacks of conventional EPI fMRI at high magnetic fields.


Asunto(s)
Artefactos , Electroencefalografía/métodos , Neuroimagen Funcional/métodos , Imagen por Resonancia Magnética/métodos , Movimiento , Ruido , Vigilia , Anestésicos por Inhalación , Animales , Imagen Eco-Planar , Análisis de Fourier , Isoflurano , Masculino , Ratas , Ratas Wistar , Inconsciencia
7.
Magn Reson Med ; 81(3): 1947-1954, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30242896

RESUMEN

PURPOSE: The sweep imaging with Fourier transformation (SWIFT) imaging technique has been shown to provide positive contrast from diluted cell suspensions labeled with super-paramagnetic iron oxide (SPIO) in a tissue, as an alternative to T2*-weighted imaging. Here we demonstrate a variation of the SWIFT technique that yields a hyperintense signal from a concentrated cell suspension. The proposed technique provides minimal background signal from host tissue and facilitates visualization of injected cells. METHODS: The proton resonance frequency and linewidth were determined for SPIO solutions of different concentrations. The original SWIFT sequence was modified and a dual saturation Gaussian shape RF pulse with ~200 Hz bandwidth was incorporated into the acquisition protocol to suppress host tissue and fat signals. This modification of the original acquisition protocol permits the detection of a hyperintense signal from grafted cells with minimal background signal from the host tissue. RESULTS: SPIO particles not only induce broadening of NMR line-width but also an initiate proton resonance frequency shift. This shift is linearly proportional to the concentration of the iron oxide particles and induced by the bulk magnetic susceptibility of SPIOs. The shift of the resonance frequency of iron labeled cells allowed us effectively suppress the host tissues with saturation RF pulse to improve MRI detection of grafted cells. CONCLUSIONS: Iron oxide particles increase the resonance frequency of water proton signal. This shift permitted us to add the tissue/fat saturation RF pulse into the original SWIFT acquisition protocol and detect distinct hyperintense signals from grafted cells with minimal background signal from the host tissue.


Asunto(s)
Compuestos Férricos , Procesamiento de Imagen Asistido por Computador/métodos , Hierro/química , Células Madre Mesenquimatosas/citología , Animales , Medios de Contraste , Femenino , Ferrocianuros/química , Análisis de Fourier , Miembro Posterior/patología , Articulaciones/diagnóstico por imagen , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Magnetismo , Nanopartículas de Magnetita/química , Trasplante de Células Madre Mesenquimatosas , Ratones , Fantasmas de Imagen , Ratas
8.
Neuroimage ; 159: 443-448, 2017 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-28797739

RESUMEN

Recently introduced 3D radial MRI pulse sequence entitled Multi-Band SWeep Imaging with Fourier Transformation (MB-SWIFT) having virtually zero acquisition delay was used to obtain functional MRI (fMRI) contrast in rat's brain at 9.4 T during deep brain stimulation (DBS). The results demonstrate that MB-SWIFT allows functional images free of susceptibility artifacts, and provides an excellent fMRI activation contrast in the brain. Flip angle dependence of the MB-SWIFT fMRI signal and elimination of the fMRI contrast while using saturation bands, indicate a blood flow origin of the observed fMRI contrast. MB-SWIFT fMRI modality permits activation studies in the close proximity to an implanted lead, which is not possible to achieve with conventionally used gradient echo and spin echo - echo planar imaging fMRI techniques. We conclude that MB-SWIFT fMRI is a powerful imaging modality for investigations of functional responses during DBS.


Asunto(s)
Encéfalo/diagnóstico por imagen , Estimulación Encefálica Profunda , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Neuroimagen/métodos , Animales , Procesamiento de Imagen Asistido por Computador/métodos , Ratas , Ratas Sprague-Dawley
9.
Magn Reson Med ; 78(5): 1900-1910, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28097749

RESUMEN

PURPOSE: Conventional T2 -weighted MRI produces a hypointense signal from iron-labeled cells, which renders quantification unfeasible. We tested a SWeep Imaging with Fourier Transformation (SWIFT) MRI pulse sequence to generate a quantifiable hyperintense signal from iron-labeled cells. METHODS: Mesenchymal stem cells (MSCs) were labeled with different concentrations of iron oxide particles and examined for cell viability, proliferation, and differentiation. The SWIFT sequence was optimized to detect and quantify the amount of iron in the muscle tissue after injection of iron oxide solution and iron-labeled MSCs. RESULTS: The incubation of MSCs with iron oxide and low concentration of poly-L-lysine mixture resulted in an internalization of up to 22 pg of iron per cell with no adverse effect on MSCs. Phantom experiments showed a dependence of SWIFT signal intensity on the excitation flip angle. The hyperintense signal from iron-labeled cells or solutions was detected, and an amount of the iron oxide in the tissue was quantified with the variable flip angle method. CONCLUSIONS: The SWIFT sequence can produce a quantifiable hyperintense MRI signal from iron-labeled cells. The graft of 18 x 106 cells was detectable for 19 days after injection and the amount of iron was quantifiable. The proposed protocol simplifies the detection and provides a means to quantify cell numbers. Magn Reson Med 78:1900-1910, 2017. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Rastreo Celular/métodos , Medios de Contraste , Imagen por Resonancia Magnética/métodos , Nanopartículas de Magnetita , Animales , Supervivencia Celular , Células Cultivadas , Medios de Contraste/farmacocinética , Medios de Contraste/toxicidad , Procesamiento de Imagen Asistido por Computador , Nanopartículas de Magnetita/química , Nanopartículas de Magnetita/toxicidad , Trasplante de Células Madre Mesenquimatosas , Células Madre Mesenquimatosas/citología , Células Madre Mesenquimatosas/metabolismo , Ratones , Fantasmas de Imagen , Procesamiento de Señales Asistido por Computador
10.
Magn Reson Med ; 78(2): 702-712, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-27667655

RESUMEN

PURPOSE: To use contrast based on longitudinal relaxation times (T1 ) or rates (R1 ) to quantify the biodistribution of iron oxide nanoparticles (IONPs), which are of interest for hyperthermia therapy, cell targeting, and drug delivery, within primary clearance organs. METHODS: Mesoporous silica-coated IONPs (msIONPs) were intravenously injected into 15 naïve mice. Imaging and mapping of the longitudinal relaxation rate constant at 24 h or 1 week postinjection were performed with an echoless pulse sequence (SWIFT). Alternating magnetic field heating measurements were also performed on ex vivo tissues. RESULTS: Signal enhancement from positive T1 contrast caused by IONPs was observed and quantified in vivo in liver, spleen, and kidney at concentrations up to 3.2 mg Fe/(g tissue wt.) (61 mM Fe). In most cases, each organ had a linear correlation between the R1 and the tissue iron concentration despite variations in intra-organ distribution, degradation, and IONP surface charge. Linear correlation between R1 and volumetric SAR in hyperthermia therapy was observed. CONCLUSION: The linear dependence between R1 and tissue iron concentration in major organs allows quantitative monitoring of IONP biodistribution in a dosage range relevant to magnetic hyperthermia applications, which falls into the concentration gap between CT and conventional MRI techniques. Magn Reson Med 78:702-712, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Medios de Contraste , Hipertermia Inducida/métodos , Imagen por Resonancia Magnética/métodos , Nanopartículas de Magnetita , Animales , Medios de Contraste/análisis , Medios de Contraste/química , Medios de Contraste/farmacocinética , Femenino , Riñón/metabolismo , Hígado/metabolismo , Nanopartículas de Magnetita/análisis , Nanopartículas de Magnetita/química , Ratones , Ratones Desnudos , Bazo/metabolismo , Distribución Tisular
11.
Magn Reson Med ; 76(6): 1932-1938, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27670251

RESUMEN

PURPOSE: To present a practical scheme of a simultaneous radiofrequency (RF) transmit (Tx) and receive (Rx) (STAR) system for MRI, discuss the challenges and solutions, and show preliminary in vivo MR images obtained with this new technique. METHODS: A remotely controlled STAR system was built and tested with a transverse electromagnetic head coil on a 4T (Oxford, 90 cm-bore) MRI scanner equipped with an Agilent DirectDrive console (Agilent, Santa Clara, CA). In vivo head images have been acquired using continuous sweep excitation and acquisition. RESULTS: The bench test and MR experimental results show our STAR system to have high isolation (60 dB) between Tx and Rx, with insensitivity to load swings created by head motion. To acquire in vivo head images, ultralow RF peak power of 50 mW was used. CONCLUSION: A novel motion-insensitive STAR MRI technique was developed and experimentally tested. The first in vivo MR images using this method were acquired. Magn Reson Med 76:1932-1938, 2016. © 2016 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Encéfalo/anatomía & histología , Imagen por Resonancia Magnética/instrumentación , Magnetismo/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación , Transductores , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
12.
Magn Reson Med ; 75(2): 537-46, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25800547

RESUMEN

PURPOSE: Methods designed to image fast-relaxing spins, such as sweep imaging with Fourier transformation (SWIFT), often utilize high excitation bandwidth and duty cycle, and in some applications the optimal flip angle cannot be used without exceeding safe specific absorption rate (SAR) levels. The aim is to reduce SAR and increase the flexibility of SWIFT by applying time-varying gradient-modulation (GM). The modified sequence is called GM-SWIFT. THEORY AND METHODS: The method known as gradient-modulated offset independent adiabaticity was used to modulate the radiofrequency (RF) pulse and gradients. An expanded correlation algorithm was developed for GM-SWIFT to correct the phase and scale effects. Simulations and phantom and in vivo human experiments were performed to verify the correlation algorithm and to evaluate imaging performance. RESULTS: GM-SWIFT reduces SAR, RF amplitude, and acquisition time by up to 90%, 70%, and 45%, respectively, while maintaining image quality. The choice of GM parameter influences the lower limit of short T2 (*) sensitivity, which can be exploited to suppress unwanted image haze from unresolvable ultrashort T2 (*) signals originating from plastic materials in the coil housing and fixatives. CONCLUSIONS: GM-SWIFT reduces peak and total RF power requirements and provides additional flexibility for optimizing SAR, RF amplitude, scan time, and image quality.


Asunto(s)
Tobillo/anatomía & histología , Encéfalo/anatomía & histología , Imagen por Resonancia Magnética/métodos , Diente/anatomía & histología , Algoritmos , Simulación por Computador , Análisis de Fourier , Humanos , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Fantasmas de Imagen
13.
Radiology ; 274(2): 540-7, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25247405

RESUMEN

PURPOSE: To report the results of sweep imaging with Fourier transformation (SWIFT) magnetic resonance (MR) imaging for diagnostic breast imaging. MATERIALS AND METHODS: Informed consent was obtained from all participants under one of two institutional review board-approved, HIPAA-compliant protocols. Twelve female patients (age range, 19-54 years; mean age, 41.2 years) and eight normal control subjects (age range, 22-56 years; mean age, 43.2 years) enrolled and completed the study from January 28, 2011, to March 5, 2013. Patients had previous lesions that were Breast Imaging Reporting and Data System 4 and 5 based on mammography and/or ultrasonographic imaging. Contrast-enhanced SWIFT imaging was completed by using a 4-T research MR imaging system. Noncontrast studies were completed in the normal control subjects. One of two sized single-breast SWIFT-compatible transceiver coils was used for nine patients and five controls. Three patients and five control subjects used a SWIFT-compatible dual breast coil. Temporal resolution was 5.9-7.5 seconds. Spatial resolution was 1.00 mm isotropic, with later examinations at 0.67 mm isotropic, and dual breast at 1.00 mm or 0.75 mm isotropic resolution. RESULTS: Two nonblinded breast radiologists reported SWIFT image findings of normal breast tissue, benign fibroadenomas (six of six lesions), and malignant lesions (10 of 12 lesions) concordant with other imaging modalities and pathologic reports. Two lesions in two patients were not visualized because of coil field of view. The images yielded by SWIFT showed the presence and extent of known breast lesions. CONCLUSION: The SWIFT technique could become an important addition to breast imaging modalities because it provides high spatial resolution at all points during the dynamic contrast-enhanced examination.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Medios de Contraste , Análisis de Fourier , Imagen por Resonancia Magnética/métodos , Adulto , Femenino , Humanos , Persona de Mediana Edad , Proyectos Piloto , Adulto Joven
14.
Magn Reson Med ; 73(2): 677-82, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24604286

RESUMEN

PURPOSE: SWIFT (SWeep Imaging with Fourier Transformation) is a non-Cartesian MRI method with unique features and capabilities. In SWIFT, radiofrequency (RF) excitation and reception are performed nearly simultaneously, by rapidly switching between transmit and receive during a frequency-swept RF pulse. Because both the transmitted pulse and data acquisition are simultaneously amplitude-modulated in SWIFT (in contrast to continuous RF excitation and uninterrupted data acquisition in more familiar MRI sequences), crosstalk between different frequency bands occurs in the data. This crosstalk leads to a "bulls-eye" artifact in SWIFT images. We present a method to cancel this interband crosstalk by cycling the pulse and receive gap positions relative to the un-gapped pulse shape. We call this strategy "gap cycling." THEORY AND METHODS: We carry out theoretical analysis, simulation and experiments to characterize the signal chain, resulting artifacts, and their elimination for SWIFT. RESULTS: Theoretical analysis reveals the mechanism for gap-cycling's effectiveness in canceling interband crosstalk in the received data. We show phantom and in vivo results demonstrating bulls-eye artifact free images. CONCLUSION: Gap cycling is an effective method to remove bulls-eye artifact resulting from interband crosstalk in SWIFT data.


Asunto(s)
Algoritmos , Artefactos , Encéfalo/anatomía & histología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
15.
Magn Reson Med ; 73(5): 1812-9, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-24919566

RESUMEN

PURPOSE: To evaluate the capability of longitudinal MR scans using sweep imaging with Fourier transformation (SWIFT) to detect breast cancer metastasis to the lung in mice. METHODS: Mice with breast cancer metastatic to the lung were generated by tail vein injection of MDA-MB-231-LM2 cells. Thereafter, MR imaging was performed every week using three different pulse sequences: SWIFT [echo time (TE) ∼3 µs], concurrent dephasing and excitation (CODE; TE ∼300 µs), and three-dimensional (3D) gradient echo (GRE; TE = 2.2 ms). Motion during the long SWIFT MR scans was compensated for by rigid-body motion correction. Maximum intensity projection (MIP) images were generated to visualize changes in lung vascular structures during the development and growth of metastases. RESULTS: SWIFT MRI was more sensitive to signals from the lung parenchyma than CODE or 3D GRE MRI. Metastatic tumor growth in the lungs induced a progressive increase in intensity of parenchymal signals in SWIFT images. MIP images from SWIFT clearly visualized lung vascular structures and their disruption due to progression of breast cancer metastases in the lung. CONCLUSION: SWIFT MRI's sensitivity to fast-decaying signals and tolerance of magnetic susceptibility enhances its effectiveness at detecting structural changes in lung parenchyma and vasculature due to breast cancer metastases in the lung.


Asunto(s)
Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/secundario , Imagen por Resonancia Magnética/métodos , Neoplasias Mamarias Experimentales/diagnóstico , Animales , Artefactos , Línea Celular Tumoral , Femenino , Análisis de Fourier , Humanos , Estudios Longitudinales , Pulmón/patología , Ratones , Ratones Desnudos , Trasplante de Neoplasias
16.
Magn Reson Med ; 74(1): 175-184, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25111731

RESUMEN

PURPOSE: To evaluate the feasibility of SWIFT with variable flip angle (VFA) for measurement of T1 relaxation time in Gd-agarose-phantoms and osteochondral specimens, including regions of very short T2 *, and compare with T1 measured using standard methods METHODS: T1 s of agarose phantoms with variable concentration of Gd-DTPA2- and nine pairs of native and trypsin-treated bovine cartilage-bone specimens were measured. For specimens, VFA-SWIFT, inversion recovery (IR) fast spin echo (FSE) and saturation recovery FSE were used. For phantoms, additionally spectroscopic IR was used. Differences and agreement between the methods were assessed using nonparametric Wilcoxon and Kruskal-Wallis tests and intraclass correlation. RESULTS: The different T1 mapping methods agreed well in the phantoms. VFA-SWIFT allowed reliable measurement of T1 in the osteochondral specimens, including regions where FSE-based methods failed. The T1 s measured by VFA-SWIFT were shifted toward shorter values in specimens. However, the measurements correlated significantly (highest correlation VFA-SWIFT versus FSE was r = 0.966). SNR efficiency was generally highest for SWIFT, especially in the subchondral bone. CONCLUSION: Feasibility of measuring T1 relaxation time using VFA-SWIFT in osteochondral specimens and phantoms was demonstrated. A shift toward shorter T1 s was observed for VFA-SWIFT in specimens, reflecting the higher sensitivity of SWIFT to short T2 * spins. Magn Reson Med 74:175-184, 2015. © 2014 Wiley Periodicals, Inc.

17.
Magn Reson Med ; 73(1): 254-62, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24523028

RESUMEN

PURPOSE: MRI relaxation measurements are performed in the presence of a fictitious magnetic field in the recently described technique known as RAFF (Relaxation Along a Fictitious Field). This method operates in the 2(nd) rotating frame (rank n = 2) by using a nonadiabatic sweep of the radiofrequency effective field to generate the fictitious magnetic field. In the present study, the RAFF method is extended for generating MRI contrasts in rotating frames of ranks 1 ≤ n ≤ 5. The developed method is entitled RAFF in rotating frame of rank n (RAFFn). THEORY AND METHODS: RAFFn pulses were designed to generate fictitious fields that allow locking of magnetization in rotating frames of rank n. Contrast generated with RAFFn was studied using Bloch-McConnell formalism together with experiments on human and rat brains. RESULTS: Tolerance to B0 and B1 inhomogeneities and reduced specific absorption rate with increasing n in RAFFn were demonstrated. Simulations of exchange-induced relaxations revealed enhanced sensitivity of RAFFn to slow exchange. Consistent with such feature, an increased grey/white matter contrast was observed in human and rat brain as n increased. CONCLUSION: RAFFn is a robust and safe rotating frame relaxation method to access slow molecular motions in vivo.


Asunto(s)
Algoritmos , Encéfalo/anatomía & histología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Animales , Femenino , Humanos , Ratas , Ratas Wistar , Reproducibilidad de los Resultados , Rotación , Sensibilidad y Especificidad
18.
Magn Reson Med ; 72(1): 160-5, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23900995

RESUMEN

PURPOSE: The signal-to-noise ratio and resolution are two competing parameters for dental MRI and are highly dependent on the radiofrequency coil configuration and performance. The purpose of this work is to describe an intraoral approach for imaging teeth with the radiofrequency coil plane oriented orthogonally to the Zeeman field to use the transverse components of the B1 field for transmitting and receiving the NMR signal. METHODS: A single loop coil with shape and size fitted to the average adult maxillary arch was built and tested with a phantom and human subjects in vivo on a whole-body 4 T MRI scanner. Supporting Biot-Savart law simulations were performed with Matlab. RESULTS: In the occlusal position (in bite plane between the upper and lower teeth), the sensitive volume of the coil encompasses the most important dental structures, the teeth and their supporting structures, while uninteresting tissues containing much higher proton density (cheeks, lips, and tongue) are outside the sensitive volume. The presented images and simulated data show the advantages of using a coil in the orthogonal orientation for dental applications. CONCLUSION: The transverse components of the B1 field of a surface coil can effectively be used for imaging of teeth and associated structures.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Enfermedades Dentales/diagnóstico , Diseño de Equipo , Humanos , Aumento de la Imagen/métodos , Fantasmas de Imagen , Relación Señal-Ruido
19.
Magn Reson Med ; 71(6): 1982-8, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24664527

RESUMEN

PURPOSE: Iron-oxide nanoparticles (IONPs) have proven utility as contrast agents in many MRI applications. Previous quantitative IONP mapping has been performed using mainly T2 * mapping methods. However, in applications requiring high IONP concentrations, such as magnetic nanoparticles based thermal therapies, conventional pulse sequences are unable to map T2 * because the signal decays too rapidly. In this article, sweep imaging with Fourier transformation (SWIFT) sequence is combined with the Look-Locker method to map T1 of IONPs in high concentrations. METHODS: T1 values of agar containing IONPs in different concentrations were measured with the SWIFT Look-Locker method and with inversion recovery spectroscopy. Precisions of Look-Locker and variable flip angle (VFA) methods were compared in simulations. RESULTS: The measured R1 (=1/T1 ) has a linear relationship with IONP concentration up to 53.6 mM of Fe. This concentration exceeds concentrations measured in previous work by almost an order of magnitude. Simulations show SWIFT Look-Locker method is also much less sensitive to B1 inhomogeneity than the VFA method. CONCLUSION: SWIFT Look-Locker can accurately measure T1 of IONP concentrations ≤53.6 mM. By mapping T1 as a function of IONP concentration, IONP distribution maps might be used in the future to plan effective magnetic nanoparticle hyperthermia therapy.


Asunto(s)
Imagenología Tridimensional , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos , Nanopartículas de Magnetita/química , Análisis de Fourier , Nanopartículas de Magnetita/análisis , Fantasmas de Imagen , Agua/química
20.
Magn Reson Med ; 72(3): 858-63, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24155275

RESUMEN

PURPOSE: The limiting factor for MRI of skeletal/mineralized tissue is fast transverse relaxation. A recent advancement in MRI technology, SWIFT (Sweep Imaging with Fourier Transform), is emerging as a new approach to overcome this difficulty. Among other techniques like UTE, ZTE, and WASPI, the application of SWIFT technology has the strong potential to impact preclinical and clinical imaging, particularly in the context of primary or metastatic bone cancers because it has the added advantage of imaging water in mineralized tissues of bone allowing MRI images to be obtained of tissues previously visible only with modalities such as computed tomography (CT). The goal of the current study is to examine the feasibility of SWIFT for the assessment of the prostate cancer induced changes in bone formation (osteogenesis) and destruction (osteolysis) in ex vivo specimens. METHODS: A luciferase expressing prostate cancer cell line (PAIII) or saline control was inoculated directly into the tibia of 6-week-old immunocompromised male mice. Tumor growth was assessed weekly for 3 weeks before euthanasia and dissection of the tumor bearing and sham tibias. The ex vivo mouse tibia specimens were imaged with a 9.4 Tesla (T) and 7T MRI systems. SWIFT images are compared with traditional gradient-echo and spin-echo MRI images as well as CT and histological sections. RESULTS: SWIFT images with nominal resolution of 78 µm are obtained with the tumor and different bone structures identified. Prostate cancer induced changes in the bone microstructure are visible in SWIFT images, which is supported by spin-echo, high resolution CT and histological analysis. CONCLUSION: SWIFT MRI is capable of high-quality high-resolution ex vivo imaging of bone tumor and surrounding bone and soft tissues. Furthermore, SWIFT MRI shows promise for in vivo bone tumor imaging, with the added benefits of nonexposure to ionizing radiation, quietness, and speed.


Asunto(s)
Adenocarcinoma/patología , Neoplasias Óseas/patología , Imagen por Resonancia Magnética/métodos , Neoplasias de la Próstata/patología , Animales , Línea Celular Tumoral , Luciferasas/metabolismo , Masculino , Ratones , Reproducibilidad de los Resultados , Tibia , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA