Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Magn Reson Imaging ; 36(3): 561-8, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22552939

RESUMEN

PURPOSE: To investigate changes in diffusion tensor imaging (DTI) measures in limbic system white matter of patients with temporal lobe epilepsy (TLE) using diffusion tensor tractography. MATERIALS AND METHODS: DTI metrics including fractional anisotropy (FA), λ1, λ2, λ3, and trace (Tr) coefficients were obtained from tractography for bilateral fornix, superior and inferior cingulum fibers in 18 patients and 10 healthy controls. Hippocampal signal-to-noise ratio (SNR) quantitative analysis was performed in order to confirm the magnetic resonance imaging (MRI) hippocampal lesion presence or absence in TLE patients. RESULTS: Nine patients presented unilateral hippocampal sclerosis (TLE+HS) and nine patients had no signal abnormalities on conventional MRI (TLE-HS). On the ipsilateral seizure side, all three investigated tracts showed significant DTI indices abnormalities in both patient groups when compared with controls, most marked on the inferior cingulum. Contralateral to the seizure side, the three tracts presented significant DTI parameters in only the TLE+HS group when compared with controls. CONCLUSION: The DTI abnormalities found in the TLE-HS group may suggest that in the inferior cingulum the structural integrity is more affected than in the fornix or superior cingulum white matter bundles. The eigenvalues taken separately add complementary information to the FA and Tr metrics and may be useful indices in better understanding the architectural reorganization of limbic system tracts in TLE patients without HS.


Asunto(s)
Imagen de Difusión Tensora/métodos , Epilepsia/patología , Interpretación de Imagen Asistida por Computador/métodos , Sistema Límbico/patología , Fibras Nerviosas Mielínicas/patología , Lóbulo Temporal/patología , Adulto , Femenino , Humanos , Vías Nerviosas/patología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
2.
Invest Radiol ; 39(1): 45-55, 2004 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-14701988

RESUMEN

RATIONALE AND OBJECTIVES: Using magnetic resonance imaging (MRI), we investigated cerebral blood and cerebrospinal fluid (CSF) flows in patients with communicating hydrocephalus (CH) and in healthy volunteers to determine the contribution of CSF flow to brain pressure regulation in CH patients. METHODS: Cine phase-contrast MRI data from 16 healthy volunteers and 12 patients with CH characterized by hyperdynamic aqueductal CSF flow were analyzed using in-house image-processing software that automatically measured flow curves. Amplitude and temporal CSF and blood flow parameters were compared in the 2 groups. RESULTS: Jugular peak flow occurred significantly earlier (P < 0.01) in the CH patients than in the healthy volunteers. Cervical CSF oscillations were not significantly different between the 2 groups. CONCLUSION: Venous vessel compression and/or changes in intracranial subarachnoid CSF flow produce an increase in ventricular CSF flush that compensates for vascular brain expansion in patients with CH.


Asunto(s)
Líquido Cefalorraquídeo/fisiología , Circulación Cerebrovascular/fisiología , Hidrocefalia/fisiopatología , Imagen por Resonancia Cinemagnética , Adolescente , Adulto , Velocidad del Flujo Sanguíneo/fisiología , Presión del Líquido Cefalorraquídeo , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Presión Intracraneal , Masculino , Factores de Tiempo
3.
Magn Reson Imaging ; 21(6): 645-50, 2003 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-12915196

RESUMEN

Magnetic Resonance Diffusion-Weighted Imaging (DWI) has been reported to be helpful for the differential diagnosis between abscesses and cystic/necrotic brain tumors. However the number of patients is still limited, and the sensitivity and specificity of the method remain to be confirmed. The primary purpose of this study was to investigate a larger sample of patients, all investigated under the same experimental conditions, in order to obtain statistically significant data. Moreover, there is no consensus about the appropriate values of b required to use to make an accurate diagnosis from DWI. The secondary purpose of this study was to determine the discriminating threshold b values for raw diffusion-weighted images and for normalized diffusion-weighted images. On the basis of 14 abscesses, 10 high-grade gliomas and 2 metastases, we show that the calculation of accurate Apparent Diffusion Coefficient (ADC) values gives a specificity rate of 100%. Without ADC calculation, we show that image normalization is required to make an accurate differential diagnosis, and we highlight the ability of DWI to discriminate between brain abscesses and cystic/necrotic brain tumors using normalized signal intensity at lower b values (503 s/mm(2)) than usual.


Asunto(s)
Absceso Encefálico/diagnóstico , Neoplasias Encefálicas/diagnóstico , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Encéfalo/patología , Niño , Preescolar , Diagnóstico Diferencial , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Necrosis , Sensibilidad y Especificidad , Estadísticas no Paramétricas
4.
J Comput Assist Tomogr ; 28(2): 247-54, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15091130

RESUMEN

OBJECTIVE: To present a novel magnetic resonance (MR) method of analysis of cerebrospinal fluid (CSF) flow dynamics. METHODS: Fifty-one subjects were explored with phase-contrast cine MR imaging. There were 36 volunteers, 9 patients with normal pressure hydrocephalus (NPH), and 6 patients with asymptomatic ventricular dilation (VD). The transfer function XFRA/CSF from the arterial pulse waves (APWs) and the CSF pulse waves (CSFPWs) and the transfer function XFRCSF/SS from the CSF pulse waves (CSFPWs) and the sagittal sinus pulse waves (SSPWs) were studied separately. RESULTS: There was a significant difference in the amplitude spectrum of the XFRA/CSF of patients with VD and volunteers (P < 0.05) and in that of patients with NPH and volunteers (P = 0.005). The amplitude of the fundamental frequency was higher in the NPH group than in the VD group (P = 0.02). In patients with NPH, the amplitude spectrum of XFRCSF/SS showed an attenuation of the pulse wave components that significantly differed from the observed amplification in healthy subjects (P = 0.009) and patients with VD (P = 0.012). CONCLUSION: This systems analysis method could help to detect increased venous compliance in VD and decreased venous compliance in NPH.


Asunto(s)
Líquido Cefalorraquídeo/fisiología , Hidrocefalia/fisiopatología , Imagen por Resonancia Cinemagnética , Adulto , Análisis de Fourier , Humanos , Hidrocefalia/diagnóstico , Hidrocéfalo Normotenso/fisiopatología , Persona de Mediana Edad , Análisis de Sistemas
5.
Eur J Nucl Med Mol Imaging ; 30(6): 859-67, 2003 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-12677300

RESUMEN

Both electrocardiographically (ECG) gated blood pool SPET (GBPS) and ECG-gated myocardial perfusion SPET (GSPET) are currently used for the measurement of global systolic left ventricular (LV) function. In this study, we aimed to compare the value of GSPET and GBPS for this purpose. The population included 65 patients who underwent rest thallium-201 GSPET imaging at 15 min after (201)Tl injection followed by planar (planar(RNA)) and GBPS equilibrium radionuclide angiography immediately after 4-h redistribution myocardial perfusion SPET imaging. Thirty-five patients also underwent LV conventional contrast angiography (X-rays). LV ejection fraction (EF) and LV volume [end-diastolic (EDV) and end-systolic (ESV) volumes] were calculated with GBPS and GSPET and compared with the gold standard methods (planar(RNA) LVEF and X-ray based calculation of LV volume). For both LVEF and LV volume, the inter-observer variability was lower with GBPS than with GSPET. GBPS LVEF was higher than planar(RNA) (P<0.01) and GSPET LVEF (P<0.01). Planar(RNA) LVEF showed a slightly better correlation with GBPS LVEF than with GSPET LVEF: r=0.87 and r=0.83 respectively. GSPET LV volume was lower than that obtained using X-rays and GBPS (P<0.01 for both). LV volume calculated using X-rays showed a slightly better correlation with GBPS LV volume than with GSPET LV volume: r=0.88 and r=0.83 respectively. On stepwise regression analysis, the accuracy of GSPET for the measurement of LVEF and LV volume was correlated with a number of factors, including planar(RNA) LVEF, signal to noise ratio, LV volume calculated using X-rays, summed rest score and acquisition scan distance (i.e. the radius of rotation). The accuracy of GBPS for the measurement of LVEF and LV volume was correlated only with the signal level, the signal to noise ratio and the acquisition scan distance. Both GSPET and GBPS provide reliable estimation of global systolic LV function. The better reliability of GBPS and in particular its lower sensitivity to different variables as compared with GSPET favours its use when precise assessment of global systolic LV function is clinically indicated.


Asunto(s)
Enfermedad Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Electrocardiografía/métodos , Imagen de Acumulación Sanguínea de Compuerta/métodos , Sístole/fisiología , Función Ventricular Izquierda/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Transporte Biológico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico por imagen , Radiofármacos/farmacocinética , Análisis de Regresión , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tecnecio/farmacocinética , Distribución Tisular , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA