RESUMEN
Background Most radiologists reporting CT colonography (CTC) do not undergo compulsory performance accreditation, potentially lowering diagnostic sensitivity. Purpose To determine whether 1-day individualized training in CTC reporting improves diagnostic sensitivity of experienced radiologists for 6-mm or larger lesions, the durability of any improvement, and any associated factors. Materials and Methods This prospective, multicenter cluster-randomized controlled trial was performed in National Health Service hospitals in England and Wales between April 2017 and January 2020. CTC services were cluster randomized into intervention (1-day training plus feedback) or control (no training or feedback) arms. Radiologists in the intervention arm attended a 1-day workshop focusing on CTC reporting pitfalls with individualized feedback. Radiologists in the control group received no training. Sensitivity for 6-mm or larger lesions was tested at baseline and 1, 6, and 12 months thereafter via interpretation of 10 CTC scans at each time point. The primary outcome was the mean difference in per-lesion sensitivity between arms at 1 month, analyzed using multilevel regression after adjustment for baseline sensitivity. Secondary outcomes included per-lesion sensitivity at 6- and 12-month follow-up, sensitivity for flat neoplasia, and effect of prior CTC experience. Results A total of 69 hospitals were randomly assigned to the intervention (31 clusters, 80 radiologists) or control (38 clusters, 59 radiologists) arm. Radiologists were experienced (median, 500-999 CTC scans interpreted) and reported CTC scans routinely (median, 151-200 scans per year). One-month sensitivity improved after intervention (66.4% [659 of 992]) compared with sensitivity in the control group (42.4% [278 of 655]; difference = 20.8%; 95% CI: 14.6, 27.0; P < .001). Improvements were maintained at 6 (66.4% [572 of 861] vs 50.5% [283 of 560]; difference = 13.0%; 95% CI: 7.4, 18.5; P < .001) and 12 (63.7% [310 of 487] vs 44.4% [187 of 421]; difference = 16.7%; 95% CI: 10.3, 23.1; P < .001) months. This beneficial effect applied to flat lesions (difference = 22.7%; 95% CI: 15.5, 29.9; P < .001) and was independent of career experience (≥1500 CTC scans: odds ratio = 1.09; 95% CI: 0.88, 1.36; P = .22). Conclusion For radiologists evaluating CT colonography studies, a 1-day training intervention yielded sustained improvement in detection of clinically relevant colorectal neoplasia, independent of previous career experience. Clinical trial registration no. NCT02892721 © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Pickhardt in this issue. An earlier incorrect version appeared online and in print. This article was corrected on February 28, 2022.
Asunto(s)
Colonografía Tomográfica Computarizada , Neoplasias Colorrectales , Colonografía Tomográfica Computarizada/métodos , Neoplasias Colorrectales/diagnóstico por imagen , Neoplasias Colorrectales/patología , Detección Precoz del Cáncer , Humanos , Estudios Prospectivos , Medicina EstatalRESUMEN
OBJECTIVES: To compare the distention quality and patient experience of oral mannitol and polyethylene glycol (PEG) for MRE. METHODS: This study is a retrospective, observational study of a subset of patients enrolled in a multicentre, prospective trial evaluating the diagnostic accuracy of MRE for small bowel Crohn's. Overall and segmental MRE small bowel distention, from 105 patients (64 F, mean age 37) was scored from 0 = poor to 4 = excellent by two experienced observers (68 [65%] mannitol and 37 [35%] PEG). Additionally, 130 patients (77 F, mean age 34) completed a questionnaire rating tolerability of various symptoms immediately and 2 days after MRE (85 [65%] receiving mannitol 45 [35%] receiving PEG). Distension was compared between agents and between those ingesting ≤ 1 L or > 1 L of mannitol using the test of proportions. Tolerability grades were collapsed into "very tolerable," "moderately tolerable," and "not tolerable." RESULTS: Per patient distension quality was similar between agents ("excellent" or "good" in 54% [37/68] versus 46% [17/37]) with mannitol and PEG respectively. Jejunal distension was significantly better with mannitol compared to PEG (40% [27/68] versus 14% [5/37] rated as excellent or good respectively). There was no significant difference according to the volume of mannitol ingested. Symptom tolerability was comparable between agents, although fullness following MRE was graded as "very tolerable" in 27% (12/45) of patients ingesting PEG, verses 44% (37/84) ingesting mannitol, difference 17% (95% CI 0.6 to 34%). CONCLUSION: Mannitol-based solutions and PEG generally achieve comparable distension quality and side effect profiles, although jejunal distension is better quality with mannitol. Neither distension quality nor side-effect profile is altered by ingestion of more than 1 L of mannitol. KEY POINTS: ⢠Mannitol-based and PEG-based oral preparation agents generally achieve comparable distension quality for MRE with the exception of the jejunum which is better distended with mannitol. ⢠Mannitol-based and PEG-based oral preparation agents used for MRE have similar side effect profiles. ⢠Neither distension quality nor side-effect profile is altered by ingestion of more than 1 L of mannitol.
Asunto(s)
Enfermedad de Crohn , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos , Adulto , Medios de Contraste/farmacología , Enfermedad de Crohn/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Manitol/farmacología , Evaluación del Resultado de la Atención al Paciente , Polietilenglicoles , Estudios Prospectivos , Estudios RetrospectivosRESUMEN
BACKGROUND: Preoperative planning is a crucial aspect of safe complete mesocolic excision (CME) surgery. 3D models derived from imaging may help improve anatomical understanding of the complex vascular anatomy. Here, we assessed the effect of 3D models on surgeons' anatomical understanding in comparison to a systematic approach for CT scan interpretation (AMIGO). METHOD: Fifteen cases were included in the study. Two GI radiology consultants reviewed each scan to ascertain the vascular anatomy. Virtual 3D models were produced and displayed on a web-based platform (https://skfb.ly/6OZUZ). A total of 13 surgical trainees were recruited. Candidates were assessed after baseline anatomical training and subsequently using the AMIGO method and 3D models. Five cases were randomly allocated in each round of testing for each participant. The primary outcome measure was an objective vascular anatomy knowledge score. The secondary outcome measure was subjective feedback from participants. RESULTS: Both 3D and AMIGO significantly improved anatomical understanding in comparison to baseline testing. However, 3D was superior to AMIGO (3D [n = 65; median score 8/14] vs. AMIGO [n = 65; median score 6/14; p < 0.0001]. For 13/15 patient cases examined, 3D was superior to the AMIGO method. Eleven participants demonstrated better anatomical understanding using 3D models versus AMIGO. Ten participants preferred 3D models in comparison to standard CT imaging. CONCLUSIONS: 3D models improve anatomical understanding of mesenteric vascular anatomy in a group of colorectal surgical trainees in comparison to a formal CT interpretation method. 3D models may be a useful planning adjunct to 2D imaging for CME surgery.
Asunto(s)
Imagenología Tridimensional , Mesocolon , Estudios Cruzados , Humanos , Mesenterio/cirugía , Mesocolon/diagnóstico por imagen , Mesocolon/cirugía , Modelos Anatómicos , Tomografía Computarizada por Rayos X/métodosRESUMEN
OBJECTIVES: To evaluate the additional diagnostic benefit of diffusion weighted imaging (DWI) and contrast enhanced (CE) images during MR enterography (MRE) of Crohn's disease. METHODS: Datasets from 73 patients (mean age 32; 40 male) (28 new-diagnosis, 45 relapsed) were read independently by two radiologists selected from a pool of 13. Radiologists interpreted datasets using three sequential sequence blocks: (1) T2 weighted and steady state free precession gradient echo (SSFP) images alone (T2^); (2) T2 weighted and SSFP images with DWI (T2 + DWI^) and; (3) T2 weighted images, SSFP, DWI and post-contrast enhanced (CE) T1 images (T2 + DWI + CE^), documenting presence, location, and activity of small bowel disease. For each sequence block, sensitivity and specificity (readers combined) was calculated against an outcome-based construct reference standard. RESULTS: 59/73 patients had small bowel disease. Per-patient sensitivity for disease detection was essentially identical (80 % [95 % CI 72, 86], 81 % [73,87], and 79 % [71,86] for T2^, T2 + DWI^and T2 + DWI + CE^respectively). Specificity was identical (82 % [64 to 92]). Per patient sensitivity for disease extent was 56 % (47,65), 56 % (47,65) and 52 % (43 to 61) respectively, and specificity was 82 % (64 to 92) for all blocks. Sensitivity for active disease was 97 % (90,99), 97 % (90,99) and 98 % (92,99), and specificity was also comparable between all sequence combination reads. Results were consistent across segments and newly diagnosed/relapse patients. CONCLUSION: There is no additional diagnostic benefit of adding either DWI or CE to T2 FSE and SSFP sequences for evaluating small bowel Crohn's disease, suggesting MRE protocols can be simplified safely.
Asunto(s)
Medios de Contraste , Enfermedad de Crohn , Imagen de Difusión por Resonancia Magnética , Sensibilidad y Especificidad , Humanos , Enfermedad de Crohn/diagnóstico por imagen , Masculino , Femenino , Adulto , Imagen de Difusión por Resonancia Magnética/métodos , Persona de Mediana Edad , Reproducibilidad de los Resultados , Adolescente , Anciano , Adulto Joven , Aumento de la Imagen/métodosRESUMEN
OBJECTIVES: To evaluate interobserver variability for diagnosis of disease presence and extent of small bowel and colonic Crohn's disease using MR enterography (MRE). METHODS: Data from the first 73 consecutive patients (mean age 32, 33F, 28 new diagnosis, 45 suspected relapse) recruited to a multicentre, prospective diagnostic accuracy trial evaluating MRE for small bowel Crohn's disease were each read independently by three (from a pool of 20) radiologists. Radiologists documented presence and segmental location of small bowel Crohn's disease and recorded morphological mural/extramural parameters for involved segments. Per patient percentage agreement for disease presence and extent were calculated against an outcome-based construct reference standard (averaged between pairs of readers). Prevalence-adjusted bias-adjusted κ (PABAK) was calculated. RESULTS: Agreement for small bowel disease presence for new diagnosis/relapsed patients was 68%(κ = 0.36)/ 78% (κ = 0.56) and 43%(κ = 0.14)/ 53% for disease extent (κ = 0.07), respectively. For disease presence, all three radiologists agreed correctly with the reference standard in 41/59 (69%) of patients with small bowel involvement, and in 8/14 (57%) cases of without small bowel disease. Agreement was highest for multisegment disease, greater than 5 cm in length, with mural thickness>6 mm, and increased mural T2 signal. Agreement for colonic disease presence was 61% (κ = 0.21 fair agreement) for new diagnosis/ 60% (κ = 0.20, slight agreement) for relapsed patients. CONCLUSION: There is a reasonable agreement between radiologists for small bowel disease presence using MRE for newly diagnosed Crohn's disease, and patients with suspected relapse, respectively. Agreement is lower for disease extent. ADVANCES IN KNOWLEDGE: There is reasonable agreement between radiologists for small bowel disease presence using MRE for newly diagnosed (68%) Crohn's disease, and patients with suspected relapse (78%). Agreement is lower for disease extent (43% new diagnosis and 53% suspected relapse).
Asunto(s)
Enfermedad de Crohn , Adulto , Ensayos Clínicos como Asunto , Enfermedad de Crohn/diagnóstico por imagen , Enfermedad de Crohn/patología , Femenino , Humanos , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Masculino , Estudios Multicéntricos como Asunto , Variaciones Dependientes del Observador , Estudios Prospectivos , RecurrenciaRESUMEN
OBJECTIVE: The objective of our study was to assess the utility of MR enterography compared with capsule endoscopy for the detection of small-bowel polyps in patients with Peutz-Jeghers syndrome (PJS). SUBJECTS AND METHODS: Adult patients with PJS scheduled for surveillance capsule endoscopy were prospectively recruited and underwent MR enterography and capsule endoscopy. Polyps > 10 mm were regarded as clinically relevant. When appropriate, large polyps (> 15 mm) were removed at enteroscopy, enabling correlation with MR enterography and capsule endoscopy findings. Interobserver agreement for MR enterography and capsule endoscopy was calculated. Patient comfort, convenience, and test preference were assessed. RESULTS: Nineteen patients (median age, 39.6 years) underwent both procedures. There was no significant difference between techniques for the detection of polyps > 10 mm (18 vs 23 polyps at capsule endoscopy and MR enterography, respectively; p = 0.35) or in the number of patients in whom > 10 mm polyps were detected (eight vs 11 patients at capsule endoscopy and MR enterography, respectively; p = 0.38). However, in three patients, large polyps (> 15 mm) detected on MR enterography were not detected on capsule endoscopy; large polyps were seen in six patients at capsule endoscopy and in nine patients at MR enterography (p = 0.25). Interobserver agreement was high for MR enterography but was only fair for capsule endoscopy (kappa = 0.81 and 0.27, respectively). Size assessments of large polyps (> 15 mm) appeared more reproducible with MR enterography than with capsule endoscopy. Patients rated capsule endoscopy as more comfortable than MR enterography. There was no significant difference between the techniques with regard to patient convenience or preference. CONCLUSION: MR enterography is a promising alternative to capsule endoscopy for small-bowel surveillance in adults with PJS. Although our results suggest that capsule endoscopy is more comfortable for the patient, MR enterography may be less prone to missing large polyps and may be more reliable in their size assessment.
Asunto(s)
Endoscopía Capsular , Pólipos Intestinales/patología , Intestino Delgado , Imagen por Resonancia Magnética/métodos , Síndrome de Peutz-Jeghers/patología , Adulto , Anciano , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Vigilancia de la Población , Estudios Prospectivos , Sistema de Registros , Reproducibilidad de los Resultados , Método Simple Ciego , Estadísticas no Paramétricas , Encuestas y CuestionariosRESUMEN
PURPOSE: To retrospectively evaluate the effect of increasing numbers of computer-aided detection (CAD)-generated false-positive (FP) marks on reader specificity and reporting times by using computed tomographic (CT) colonography in a low-prevalence screening population. MATERIALS AND METHODS: Ethics committee approval and informed consent were obtained for this HIPAA-compliant study. Four readers each read 48 data sets (26 men, 22 women; mean age, 57 years) from a screening population (three containing polyps) without CAD application, followed by review of the CAD output and recorded findings and diagnostic confidence. The 45 data sets that were designated as normal were chosen such that 22 generated 15 or fewer FP CAD marks and 23 generated more than 15 FP CAD marks. Sensitivity, specificity, and receiver operating characteristic (ROC) curves were calculated with and without CAD. The relationships between the number of CAD FP marks and reader confidence, reporting times, and correct data set classification were analyzed by using linear and logistic regression. RESULTS: Across all readers, CAD resulted in four additional FP detections. Overall reader sensitivity and specificity (6-mm polyp threshold) before and after CAD application were 0.75 (95% confidence interval [CI]: 0.43, 0.95) versus 0.83 (95% CI: 0.52, 0.98) and 0.96 (95% CI: 0.91, 0.98) versus 0.93 (95% CI: 0.88, 0.96), respectively. The area under the ROC curve increased from 0.57 (95% CI: 0.34, 0.80) to 0.61 (95% CI: 0.42, 0.80). There was no correlation between an increasing number of CAD FP marks and reader confidence (P = .71) or correct study classification (P = .23), but there was a positive correlation with CAD-assisted reading times (0.06 [95% CI: 0.02, 0.10], P = .002). CONCLUSION: Increasing numbers of CAD FP marks did not adversely influence correct reader study classification or diagnostic confidence, although reporting times did increase.