Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 92(7): E453-E455, 2018 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-30019821

RESUMEN

Complex Coronary artery to Pulmonary artery fistulas (CPFs) can be difficult to manage with embolization or ligation. An 88-year-old woman with exertional angina was found to have a complex precordial CPF, severe Mitral regurgitation, and Pulmonary Hypertension. CPF treatment was recommended prior to minimally invasive mitral valve replacement (to avoid postoperative myocardial ischemia from worsened steal). The CPF was supplied by multiple branches from the LAD and RCA, and formed a complex common varicosity with multiple drainage channels to the pulmonary artery. The CPF was treated by injecting a liquid embolic agent, Ethylene Vinyl Alcohol Copolymer (Onyx, Medtronic, MN), into two of the feeding arteries arising from the RCA through a Scepter C Dual lumen balloon micro catheter (Microvention, Aliso Viejo, CA. This resulted in complete obliteration of the fistula, and the patient subsequently underwent successful mitral valve replacement surgery.


Asunto(s)
Fístula Arterio-Arterial/terapia , Oclusión con Balón , Anomalías de los Vasos Coronarios/terapia , Embolización Terapéutica/métodos , Polivinilos/administración & dosificación , Arteria Pulmonar/anomalías , Anciano de 80 o más Años , Fístula Arterio-Arterial/diagnóstico por imagen , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Embolización Terapéutica/instrumentación , Femenino , Humanos , Inyecciones Intraarteriales , Arteria Pulmonar/diagnóstico por imagen , Resultado del Tratamiento
2.
Neuroradiology ; 60(5): 529-533, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29497786

RESUMEN

PURPOSE: Contrast-induced nephropathy is a common clinical concern in patients undergoing neuroendovascular procedures, especially in those with pre-existent kidney disease. We aimed to define the incidence of contrast-induced nephropathy in these high-risk patients in our practice. METHODS: We analyzed data retrospectively from patients undergoing neuroendovascular procedures at two academic medical centers over a 4-year period. Contrast-induced nephropathy was determined by an absolute increase in serum creatinine of 0.5 mg/dL or a rise from its baseline value by ≥ 25%, at 48-72 h after exposure to contrast agent after excluding other causes of renal impairment. High-risk patients were identified as those with pre-procedural estimated glomerular filtration rate < 60 mL/min irrespective of creatinine level, corresponding to stages 3-5 of chronic kidney disease. RESULTS: One hundred eighty-five high-risk patients undergoing conventional cerebral angiography and neuroendovascular interventions were identified. Only 1 out of 184 (0.54%) high-risk patients developed contrast-induced nephropathy. That one patient had stage 5 chronic kidney disease and multiple other risk factors. CONCLUSION: We have observed a very low rate of renal injury in patients with chronic kidney disease, traditionally considered high risk for neuroendovascular procedures. Multiple factors may be responsible in the risk reduction of contrast-induced nephropathy in this patient population.


Asunto(s)
Angiografía Cerebral , Medios de Contraste/toxicidad , Procedimientos Endovasculares , Seguridad del Paciente , Insuficiencia Renal Crónica/inducido químicamente , Ácidos Triyodobenzoicos/toxicidad , Anciano , Femenino , Tasa de Filtración Glomerular , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia Renal Crónica/epidemiología , Estudios Retrospectivos
4.
J Vasc Interv Radiol ; 25(4): 587-92, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24674217

RESUMEN

Balloon-assisted embolization performed by delivering Onyx ethylene vinyl alcohol copolymer through a dual-lumen coaxial balloon microcatheter is a new technique for the management of peripheral vascular lesions. This technique does not require an initial reflux of Onyx to form around the tip of the microcatheter before antegrade flow of Onyx can commence. In a series of four patients who were treated with the use of this technique, the absence of significant reflux of Onyx was noted, as were excellent navigability and easy retrieval of the balloon microcatheter. However, in one patient, there was inadvertent adverse embolization of a digital artery, which was not caused by reflux of Onyx but could still be related to balloon inflation.


Asunto(s)
Oclusión con Balón/instrumentación , Dimetilsulfóxido/administración & dosificación , Embolización Terapéutica/instrumentación , Procedimientos Endovasculares/instrumentación , Polivinilos/administración & dosificación , Dispositivos de Acceso Vascular , Enfermedades Vasculares/terapia , Adolescente , Adulto , Angiografía de Substracción Digital , Oclusión con Balón/efectos adversos , Embolización Terapéutica/efectos adversos , Embolización Terapéutica/métodos , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/métodos , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Miniaturización , Resultado del Tratamiento , Enfermedades Vasculares/diagnóstico
5.
Heliyon ; 10(10): e30106, 2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38799748

RESUMEN

Objective: Natural language processing (NLP) can generate diagnoses codes from imaging reports. Meanwhile, the International Classification of Diseases (ICD-10) codes are the United States' standard for billing/coding, which enable tracking disease burden and outcomes. This cross-sectional study aimed to test feasibility of an NLP algorithm's performance and comparison to radiologists' and physicians' manual coding. Methods: Three neuroradiologists and one non-radiologist physician reviewers manually coded a randomly-selected pool of 200 craniospinal CT and MRI reports from a pool of >10,000. The NLP algorithm (Radnosis, VEEV, Inc., Minneapolis, MN) subdivided each report's Impression into "phrases", with multiple ICD-10 matches for each phrase. Only viewing the Impression, the physician reviewers selected the single best ICD-10 code for each phrase. Codes selected by the physicians and algorithm were compared for agreement. Results: The algorithm extracted the reports' Impressions into 645 phrases, each having ranked ICD-10 matches. Regarding the reviewers' selected codes, pairwise agreement was unreliable (Krippendorff α = 0.39-0.63). Using unanimous reviewer agreement as "ground truth", the algorithm's sensitivity/specificity/F2 for top 5 codes was 0.88/0.80/0.83, and for the single best code was 0.67/0.82/0.67. The engine tabulated "pertinent negatives" as negative codes for stated findings (e.g. "no intracranial hemorrhage"). The engine's matching was more specific for shorter than full-length ICD-10 codes (p = 0.00582x10-3). Conclusions: Manual coding by physician reviewers has significant variability and is time-consuming, while the NLP algorithm's top 5 diagnosis codes are relatively accurate. This preliminary work demonstrates the feasibility and potential for generating codes with reliability and consistency. Future works may include correlating diagnosis codes with clinical encounter codes to evaluate imaging's impact on, and relevance to care.

6.
AJR Am J Roentgenol ; 201(3): 631-8, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23971457

RESUMEN

OBJECTIVE: Although posterior reversible encephalopathy syndrome (PRES) typically involves cortical or subcortical edema of the cerebrum, only individual cases have been described of a variant involving the central brainstem and basal ganglia and lacking cortical and subcortical edema. We evaluated FLAIR and T2-weighted images of 124 patients with confirmed PRES to determine the incidence of this uncommon variant, which we refer to as the "central variant"; to determine which structures are involved in this variant; and to determine the associated causes. CONCLUSION: We found that five of the 124 patients (4%) with PRES had MR findings consistent with the central variant-that is, either brainstem or basal ganglia involvement and a lack of cortical or subcortical edema of the cerebrum. The thalami were involved in all five PRES patients with MR findings consistent with the central variant, but there was variable involvement of the posterior limb of the internal capsule (4/5), cerebellum (3/5), and periventricular white matter (3/5); in each patient, there was improvement both clinically and on MRI. The causes of PRES in these five patients were hypertension (n=2), cyclosporine (n=2), and eclampsia (n=1). The incidence of the central variant may be increasing because of an improving awareness of the diverse imaging patterns of PRES.


Asunto(s)
Ganglios Basales/patología , Tronco Encefálico/patología , Imagen por Resonancia Magnética/métodos , Síndrome de Leucoencefalopatía Posterior/patología , Adulto , Edema Encefálico/patología , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
7.
Neuroimage ; 60(2): 1073-82, 2012 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-22305993

RESUMEN

Gradient Echo Plural Contrast Imaging (GEPCI) is a post processing technique that, based on a widely available multiple gradient echo sequence, allows simultaneous generation of naturally co-registered images with various contrasts: T1 weighted, R2*=1/T2* maps and frequency (f) maps. Herein, we present results demonstrating the capability of GEPCI technique to generate image sets with additional contrast characteristics obtained by combing the information from these three basic contrast maps. Specifically, we report its ability to generate GEPCI-susceptibility weighted images (GEPCI-SWI) with improved SWI contrast that is free of T1 weighting and RF inhomogeneities; GEPCI-SWI-like images with the contrast similar to original SWI; T1f images that offer superior GM/WM matter contrast obtained by combining the GEPCI T1 and frequency map data; Fluid Suppressed T2* (FST2*) images that utilize GEPCI T1 data to suppress CSF signal in T2* maps and provide contrast similar to FLAIR T2 weighted images; and T2*-SWI images that combine SWI contrast with quantitative T2* map and offer advantages of visualizing venous structure with hyperintense T2* lesions (e.g. MS lesions). To analyze GEPCI images we use an improved algorithm for combining data from multi-channel RF coils and a method for unwrapping phase/frequency maps that takes advantage of the information on phase evolution as a function of gradient echo time in GEPCI echo train.


Asunto(s)
Encéfalo/fisiología , Neuroimagen Funcional , Imagen por Resonancia Magnética/métodos , Humanos
8.
Interv Neuroradiol ; : 15910199221135052, 2022 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-36299241

RESUMEN

INTRODUCTION: Spinal angiography (SpAn) is the gold standard for diagnosis of spinal dural fistulas and arteriovenous malformations. A complete spinal angiogram necessitates the interrogation of the segmental arteries arising from the aorta at every level as well, the internal iliac; and median sacral arteries at the caudal end; and the cervical vasculature at the cranial end. SpAn has traditionally been performed with transfemoral arterial access and could be challenging. Of late, transradial arterial access has emerged as a popular alternative for endovascular surgical Neuroradiology (ESN) procedures including SpAn. However, there is paucity of the literature regarding transradial access for spinal angiography. METHODS: After IRB approval, records and imaging were reviewed in a series of patients who underwent SpAn at our institution. RESULTS: A total of nine spinal angiograms were performed via transradial access in a consecutive series of eight patients between July 2019 and December 2020 at our institution. Eight of these were diagnostic SpAn's, and one patient underwent SpAn with transradial approach for the treatment of a type I spinal dural arteriovenous fistula. No complications occurred during or subsequent to the procedures. CONCLUSION: SpAn can be successfully and safely accomplished via transradial access. This approach appears to provide a stable method for interventions, as well.

9.
ACS Appl Mater Interfaces ; 14(37): 41659-41670, 2022 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-36070361

RESUMEN

Deep-seated tumors of the liver, brain, and other organ systems often recur after initial surgical, chemotherapeutic, radiation, or focal treatments. Repeating these treatments is often invasive and traumatic. We propose an iron oxide nanoparticle (IONP)-enhanced precipitating hydrophobic injectable liquid (PHIL, MicroVention inc.) embolic as a localized dual treatment implant for nutrient deprivation and multiple repeatable thermal ablation. Following a single injection, multiple thermal treatments can be repeated as needed, based on monitoring of tumor growth/recurrence. Herein we show the ability to create an injectable stable PHIL-IONP solution, monitor deposition of the PHIL-IONP precipitate dispersion by µCT, and gauge the IONP distribution within the embolic by magnetic resonance imaging. Once precipitated, the implant could be heated to reach therapeutic temperatures >8 °C for thermal ablation (clinical temperature of ∼45 °C), in a model disk and a 3D tumor bed model. Heat output was not affected by physiological conditions, multiple heating sessions, or heating at intervals over a 1 month duration. Further, in ex vivo mice hind-limb tumors, we could noninvasively heat the embolic to an "ablative" temperature elevation of 17 °C (clinically 54 °C) in the first 5 min and maintain the temperature rise over +8 °C (clinically a temperature of 45 °C) for longer than 15 min.


Asunto(s)
Embolización Terapéutica , Neoplasias , Animales , Dimetilsulfóxido , Embolización Terapéutica/métodos , Calefacción , Nanopartículas Magnéticas de Óxido de Hierro , Ratones , Neoplasias/tratamiento farmacológico , Polivinilos/uso terapéutico
10.
Stroke ; 42(11): 3127-31, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21940964

RESUMEN

BACKGROUND AND PURPOSE: The purpose of this study was to determine the utility of postcontrast susceptibility-weighted MRI (PCSWI) in the evaluation of vascular malformations of the brain (BVM). METHODS: We retrospectively evaluated PCSWI and digital subtraction angiography data from 16 consecutive patients with known or suspected BVM, which had been entered into a prospectively maintained database during a 1-year period. There had been no intervening treatment or change in patients' symptoms between the PCSWI and digital subtraction angiography studies. The use of PCSWI in the detection of arteriovenous shunting was compared with that of routine noncontrast susceptibility-weighted imaging, time-of-flight MR angiography, and contrast-enhanced MR angiography using digital subtraction angiography results as the reference standard. The presence of arteriovenous shunting in PCSWI or susceptibility-weighted imaging sequences was defined by the presence of abnormal signal hyperintensity in the venous structures adjacent to the BVM. RESULTS: A total of 17 BVMs were identified by digital subtraction angiography (9 newly diagnosed arteriovenous malformations, 3 dural arteriovenous fistulas, 4 treated arteriovenous malformations with residual arteriovenous shunting, and 1 complex developmental venous anomaly). PCSWI was 100% sensitive and 100% specific with 100% positive predictive value and 100% negative predictive value for the detection of arteriovenous shunting in these BVMs. The PCSWI/susceptibility-weighted imaging signal intensity ratio in the most prominent early draining venous structure was 1.2±0.32. CONCLUSIONS: PCSWI appears to be superior to susceptibility-weighted imaging, time-of-flight MR angiography, and contrast-enhanced MR angiography in detecting arteriovenous shunting in BVMs and may be useful in the initial diagnosis and follow-up of patients with BVMs.


Asunto(s)
Angiografía de Substracción Digital/tendencias , Encéfalo/diagnóstico por imagen , Malformaciones Arteriovenosas Intracraneales/diagnóstico por imagen , Angiografía por Resonancia Magnética/tendencias , Adulto , Encéfalo/irrigación sanguínea , Estudios de Cohortes , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Estudios Retrospectivos
11.
Stroke ; 42(1): 87-92, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21088245

RESUMEN

BACKGROUND AND PURPOSE: to determine the accuracy of susceptibility-weighted MRI (SWI) for the detection of arteriovenous shunting (AVS) in vascular malformations of the brain (BVM). METHODS: we retrospectively identified 60 patients who had been evaluated for known or suspected BVM by both SWI and digital subtraction angiography, without intervening treatment, during a 3-year period. SWI images were retrospectively assessed by 2 independent reviewers for the presence of AVS as determined by the presence of signal hyperintensity within a venous structure in the vicinity of the BVM. Discrepancies were resolved by consensus among a panel of 3 neuroradiologists. Accuracy parameters of SWI for the detection of AVS were calculated using digital subtraction angiography as the reference standard. RESULTS: a total of 80 BVM were identified in the 60 patients included in our study. Of the 29 BVM with AVS on digital subtraction angiography, 14 were untreated arteriovenous malformations, 10 were previously treated arteriovenous malformations, and 5 were untreated dural arteriovenous fistulas. Overall, SWI was 93% sensitive and 98% specific for the detection of AVS in BVM, with excellent interobserver agreement (κ=0.94). In the 14 previously treated arteriovenous malformations, SWI was 100% sensitive and specific for the detection of AVS. In the 28 BVM associated with intracerebral hemorrhage, SWI was 100% sensitive and 96% specific for the detection of AVS. CONCLUSIONS: SWI is accurate for the detection of arteriovenous shunting in vascular malformations of the brain and, for some patients, SWI may offer a noninvasive alternative to angiography in screening for or follow-up of treated BVM.


Asunto(s)
Angiografía de Substracción Digital/métodos , Anastomosis Arteriovenosa/diagnóstico por imagen , Malformaciones Vasculares del Sistema Nervioso Central/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Anastomosis Arteriovenosa/cirugía , Malformaciones Vasculares del Sistema Nervioso Central/cirugía , Femenino , Humanos , Masculino , Estudios Retrospectivos , Sensibilidad y Especificidad
12.
Interv Neuroradiol ; 27(2): 298-306, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33164616

RESUMEN

BACKGROUND: The use of compliant dual lumen balloon microcatheters (CDLB) for the endovascular treatment of vascular malformations, wide neck aneurysms, and intracranial angioplasty (for vasospasm) is well documented. Navigation of 4 mm or larger CDLB within tortuous and small distal intracranial vessels can be challenging. Recently, the lower profile Scepter Mini balloon microcatheter (SMB) has been approved for use, with potential for improved intracranial navigation. OBJECTIVE: Discuss operative experience of Scepter Mini (Microvention, Aliso Viejo, CA). METHODS: We describe our initial experience with the SMB in a series of nine patients. RESULTS: The balloon microcatheter was used for delivery of liquid embolic in six patients (Case 1, 2, 6-9), adjunct support for delivery or positioning of the Woven Endobridge (WEB) device in two (Case 3,4), and gentle post-deployment repositioning of a WEB device in the last one (Case 5). We were able to successfully navigate the SMB over a 0.008 "micro wire to the target lesion in all the patients. We experienced initial difficulty with injecting liquid embolic in Case 2. We postulate that the SMB was in a tortuous segment of a dural vessel in this patient, and that it kinked on inflation with occlusion of the liquid embolic delivery lumen; this was overcome with slightly proximal repositioning and reinflation of the SMB. CONCLUSION: Our initial experience shows that the SMB has potential to be useful in endovascular neurosurgical procedures requiring balloon assistance within smaller diameter blood vessels.


Asunto(s)
Oclusión con Balón , Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Investigación , Resultado del Tratamiento
13.
J Neurointerv Surg ; 13(10): 935-941, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33526480

RESUMEN

BACKGROUND: Catheter retention and difficulty in retrieval have been observed during embolization of brain arteriovenous malformations (bAVMs) with the Onyx liquid embolic system (Onyx). The Apollo Onyx delivery microcatheter (Apollo) is a single lumen catheter designed for controlled delivery of Onyx into the neurovasculature, with a detachable distal tip to aid catheter retrieval. This study evaluates the safety of the Apollo for delivery of Onyx during embolization of bAVMs. METHODS: This was a prospective, non-randomized, single-arm, multicenter, post-market study of patients with a bAVM who underwent Onyx embolization with the Apollo between May 2015 and February 2018. The primary endpoint was any catheter-related adverse event (AE) at 30 days, such as unintentional tip detachment or malfunction with clinical sequelae, or retained catheter. Procedure-related AEs (untoward medical occurrence, disease, injury, or clinical signs) and serious AEs (life threatening illness or injury, permanent physiological impairment, hospitalization, or requiring intervention) were also recorded. RESULTS: A total of 112 patients were enrolled (mean age 44.1±17.6 years, 56.3% men), and 201 Apollo devices were used in 142 embolization procedures. The mean Spetzler-Martin grade was 2.38. The primary endpoint was not observed (0/112, 0%). The catheter tip detached during 83 (58.5%) procedures, of which 2 (2.4%) were unintentional and did not result in clinical sequelae. At 30 days, procedure related AEs occurred in 26 (23.2%) patients, and procedure-related serious AEs in 12 (10.7%). At 12 months, there were 3 (2.7%) mortalities, including 2 (1.8%) neurological deaths, none of which were device-related. CONCLUSION: This study demonstrates the safety of Apollo for Onyx embolization of bAVMs. CLINICAL TRIAL REGISTRATION: CNCT02378883.


Asunto(s)
Embolización Terapéutica , Malformaciones Arteriovenosas Intracraneales , Adulto , Encéfalo , Dimetilsulfóxido/efectos adversos , Embolización Terapéutica/efectos adversos , Femenino , Humanos , Malformaciones Arteriovenosas Intracraneales/diagnóstico por imagen , Malformaciones Arteriovenosas Intracraneales/terapia , Masculino , Persona de Mediana Edad , Polivinilos/efectos adversos , Estudios Prospectivos , Resultado del Tratamiento
14.
Magn Reson Imaging Clin N Am ; 28(4): 583-591, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33040998

RESUMEN

Interventional MR imaging procedures are rapidly growing in number owing to the excellent soft tissue resolution of MR imaging, lack of ionizing radiation, hardware and software advancements, and technical developments in MR imaging-compatible robots, lasers, and ultrasound equipment. The safe operation of an interventional MR imaging system is a complex undertaking, which is only possible with multidisciplinary planning, training, operations and oversight. Safety for both patients and operators is essential for successful operations. Herein, we review the safety concerns, solutions and challenges associated with the operation of a modern interventional MR imaging system.


Asunto(s)
Cuidados Intraoperatorios/métodos , Imagen por Resonancia Magnética Intervencional/métodos , Seguridad del Paciente , Cirugía Asistida por Computador/métodos , Humanos , Imagen por Resonancia Magnética Intervencional/efectos adversos , Guías de Práctica Clínica como Asunto
15.
Neurosurgery ; 86(2): E156-E163, 2020 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-31758197

RESUMEN

BACKGROUND: Because of the overwhelming benefit of thrombectomy for highly selected trial patients with large vessel occlusion (LVO), some trial-ineligible patients are being treated in practice. OBJECTIVE: To determine the safety and efficacy of thrombectomy in DAWN/DEFUSE-3-ineligible patients. METHODS: Using a multicenter prospective observational study of consecutive patients with anterior circulation LVO who underwent late thrombectomy, we compared symptomatic intracerebral hemorrhage (sICH) and good outcome (90-d mRS 0-2) among DAWN/DEFUSE-3-ineligible patients to trial-eligible patients and to untreated DAWN/DEFUSE-3 controls. RESULTS: Ninety-eight patients had perfusion imaging and underwent thrombectomy >6 h; 46 (47%) were trial ineligible (41% M2 occlusions, 39% mild deficits, 28% ASPECTS <6). In multivariable regression, the odds of a good outcome (aOR 0.76, 95% CI 0.49-1.19) and sICH (aOR 3.33, 95% CI 0.42-26.12) were not different among trial-ineligible vs eligible patients. Patients with mild deficits were more likely to achieve a good outcome (aOR 3.62, 95% CI 1.48-8.86) and less sICH (0% vs 10%, P = .16), whereas patients with ASPECTS <6 had poorer outcomes (aOR 0.14, 95% CI 0.05-0.44) and more sICH (aOR 24, 95% CI 5.7-103). Compared to untreated DAWN/DEFUSE-3 controls, trial-ineligible patients had more sICH (13%BEST vs 3%DAWN [P = .02] vs 4%DEFUSE [P = .05]), but were more likely to achieve a good outcome at 90 d (36%BEST vs 13%DAWN [P < .01] vs 17%DEFUSE [P = .01]). CONCLUSION: Thrombectomy is used in practice for some patients ineligible for the DAWN/DEFUSE-3 trials with potentially favorable outcomes. Additional trials are needed to confirm the safety and efficacy of thrombectomy in broader populations, such as large core infarction and M2 occlusions.


Asunto(s)
Isquemia Encefálica/diagnóstico por imagen , Isquemia Encefálica/cirugía , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/cirugía , Trombectomía/métodos , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Trombectomía/tendencias , Resultado del Tratamiento
16.
World Neurosurg ; 129: 276, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31226456

RESUMEN

Woven EndoBridge (WEB) is an intrasaccular flow-disrupting device that has recently been approved by the U.S. Food and Drug Administration (FDA) for treatment of wide-neck ruptured and unruptured aneurysms at arterial bifurcations. Successful and effective treatment of aneurysms with the WEB device requires accurate sizing. For optimal positioning of the WEB device within the aneurysm sac, the diameter of the device has to exceed by the mean diameter of the aneurysm by 1.0 mm. However, this predictably results in an increase in the height of the device. In shallow, wide-necked aneurysms, this increase in height of the WEB device could result in encroachment of the device on the parent artery or branch vessel origins. In these circumstances, the placement of an intracranial stent can prevent such encroachment. In this video, we demonstrate the operative technique of stent-assisted WEB device placement that was performed at our institution for the treatment of a recurrent basilar apex aneurysm (Video 1). This previously ruptured aneurysm had been treated initially with primary coil embolization, and the patient consented to endovascular treatment of her aneurysm recurrence. The video illustrates this procedure using a combination of fluoroscopic images, fluoroscopic cines, and digital subtraction angiograms.


Asunto(s)
Implantación de Prótesis Vascular/métodos , Embolización Terapéutica/instrumentación , Embolización Terapéutica/métodos , Aneurisma Intracraneal/terapia , Aneurisma Roto/terapia , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/métodos , Femenino , Humanos , Recurrencia , Stents
17.
Interv Neuroradiol ; 25(3): 301-304, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30567455

RESUMEN

INTRODUCTION: Mechanical thrombectomy in the setting of acute ischemic stroke (AIS) requires cerebral digital subtraction angiography (DSA), typically performed with iodinated contrast medium. We present a case of emergent cerebral DSA and mechanical thrombectomy using gadolinium-based contrast for cerebral DSA in a patient with a history of anaphylaxis to iodinated contrast agents (ICs). CASE REPORT: A 72-year-old man developed left ventricle assist device thrombus while on anticoagulation. During hospitalization he suffered right middle cerebral artery occlusion with a National Institutes of Health stroke scale score of 10. He had a history of anaphylaxis and the advanced directives revealed do not resuscitate/do not intubate status. We performed an emergent DSA as part of thrombectomy procedure using gadolinium-based contrast mixed in 1:1 proportion with normal saline. The images obtained were of adequate quality and the patient underwent successful thrombectomy with modified thrombolysis in cerebral infarction 2B recanalization. CONCLUSION: Gadolinium-based contrast agents could be effective alternatives for cerebral DSA in patients undergoing mechanical thrombectomy for AIS who have a history of anaphylactic reaction to ICs.


Asunto(s)
Angiografía de Substracción Digital/métodos , Isquemia Encefálica/diagnóstico por imagen , Isquemia Encefálica/cirugía , Medios de Contraste , Gadolinio , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/cirugía , Trombectomía/métodos , Anciano , Anafilaxia/prevención & control , Infarto Cerebral/diagnóstico por imagen , Infarto Cerebral/cirugía , Hipersensibilidad a las Drogas , Corazón Auxiliar , Humanos , Masculino
18.
World Neurosurg ; 127: e251-e260, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30898757

RESUMEN

OBJECTIVE: Although canine stroke models have several intrinsic advantages, establishing consistent and reproducible territorial stroke in these models has been challenging because of the abundance of collateral circulation. We have described a skull-base surgical approach that yields reproducible stroke volumes. METHODS: Ten male beagles were studied. In all 10 dogs, a craniectomy was performed to expose the circle of Willis. Cerebral aneurysm clips were temporarily applied to the middle cerebral artery (MCA), anterior cerebral artery (ACA), posterior cerebral artery, and/or ophthalmic artery (OA) for 1 hour, followed by cauterization of the distal MCA pial collateral vessels. Indocyanine green angiography was performed to assess the local blood flow to the intended area of infarction. The dogs' neurologic examination was evaluated, and the stroke burden was quantified using magnetic resonance imaging. RESULTS: High mortality was observed after 1-hour clip occlusion of the posterior cerebral artery, MCA, ACA, and OA (n = 4). Without coagulation of the MCA collateral vessels, 1-hour occlusion of the MCA and/or ACA and OA yielded inconsistent stroke volumes (n = 2). In contrast, after coagulation of the distal MCA pial collateral vessels, 1-hour occlusion of the MCA, ACA, and OA yielded consistent territorial stroke volumes (n = 4; average stroke volume, 9.13 ± 0.90 cm3; no surgical mortalities), with reproducible neurologic deficits. CONCLUSION: Consistent stroke volumes can be achieved in male beagles using a skull base surgical approach with temporary occlusion of the MCA, ACA, and OA when combined with cauterization of the distal MCA pial collateral vessels.


Asunto(s)
Modelos Animales de Enfermedad , Perros , Infarto de la Arteria Cerebral Media/etiología , Animales , Conducta Animal , Encéfalo/patología , Angiografía Cerebral , Arterias Cerebrales/patología , Circulación Colateral , Constricción , Craneotomía , Electrocoagulación , Infarto de la Arteria Cerebral Media/diagnóstico por imagen , Infarto de la Arteria Cerebral Media/patología , Imagen por Resonancia Magnética/métodos , Masculino , Reproducibilidad de los Resultados , Base del Cráneo/cirugía
19.
Interv Neurol ; 7(6): 439-444, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30410522

RESUMEN

BACKGROUND/OBJECTIVE: Compliant dual-lumen balloon microcatheters have been used to perform balloon-assisted embolization (BAE) of brain arteriovenous malformations (AVMs) with ethylene vinyl alcohol copolymer (Onyx). However, vessel rupture and microcatheter retention have been reported from BAE using these microcatheters. Using an extra-compliant balloon microcatheter (Scepter XC; Microvention, Tustin, CA, USA) could help avoid pial vessel rupture during BAE. We herein report our experience using this balloon microcatheter for BAE. METHODS: This retrospective study included patients who underwent BAE of brain AVMs at our institution between June 2012 and March 2017. RESULTS: The extra-compliant Scepter XC balloon microcatheter was used for BAE of brain AVMs in 23 patients aged 44.3 ± 16.7 years (range 0-65 years). A total of 40 intracranial vessels (39 pial arteries and 1 pial vein) were catheterized and embolized during 30 separate sessions. In all instances, the balloon microcatheter could be successfully advanced to the AVM nidus. A mean volume of 2.4 ± 1.7 mL (range 0.65-4.6 mL) of Onyx was injected per session. There were no instances of vessel rupture, microcatheter retention, or stroke. CONCLUSION: Utilization of the extra-compliant balloon microcatheter results in safe and effective BAE, which adds to the growing experience with BAE for AVM treatment.

20.
Interv Neurol ; 6(1-2): 31-35, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28611831

RESUMEN

BACKGROUND: The pipeline embolization device (PED; Medtronic, MN, USA) can sometimes herniate into the aneurysmal sac in an unexpected manner during or shortly after its deployment due to device foreshortening. In this report, we describe 2 endovascular techniques, which can be used to reposition a herniated PED construct into a more favorable alignment. SUMMARY: In a 67-year-old patient who had an intraprocedural herniation of a PED device into a giant cavernous aneurysm, a stent anchor technique was used to reverse the herniation, reorient the PED construct, and achieve successful flow diversion. In a different patient with a giant superior hypophyseal aneurysm, a balloon anchor technique followed by deployment of an LVIS Jr (Microvention, Tustin, CA, USA) stent was used to reverse the herniation into the aneurysmal sac. KEY MESSAGES: Stent anchor and balloon anchor techniques as described here can be used to reposition PED constructs, which have unexpectedly herniated into the aneurysm sac during attempted flow diversion for the treatment of giant aneurysms.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA