Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Q J Nucl Med Mol Imaging ; 67(1): 57-68, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34309334

RESUMEN

BACKGROUND: The aim of this phantom study was to optimize the [68Ga]Ga-PSMA PET/CT examination in terms of scan time duration and image reconstruction parameters, in combination with PSF and TOF modelling, in a digital Biograph Vision PET/CT scanner. METHODS: Three types of phantoms were used: 1) soft-tissue tumor phantom consisting of six spheres mounted in a torso phantom; 2) bone-lung tumor phantom; 3) resolution phantom. Phantom inserts were filled with activity concentrations (ACs) that were derived from clinical data. Phantom data were acquired in list-mode at one bed position. Images with emission data ranging from 30 to 210 s in 30-s increments were reconstructed from a reference image acquired with 3.5-min emission. Iterative image reconstruction (OSEM), point-spread-function (PSF) and time-of-flight (TOF) options were applied using different iterations, Gaussian filters, and voxel sizes. The criteria for image quality was lesion detectability and lesion quantification, evaluated as contrast-to-noise ratio (CNR) and maximum AC (peak AC), respectively. A threshold value of CNR above 6 and percentage maximum AC (peak AC) deviation range of ±20% of the reference image were considered acceptable. The proposed single-bed scan time reduction was projected to a whole-body examination (patient validation scan) using the continuous-bed-motion mode. RESULTS: Sphere and background ACs of 20 kBq/mL and 1 kBq/mL were selected, respectively. The optimized single-bed scan time was approximately 60 s using OSEM-TOF or OSEM-TOF+PSF (four iterations, 4.0-mm Gaussian filter and almost isotropic voxel size of 3.0-mm side length), resulting in a PET spatial resolution of 6.3 mm for OSEM-TOF and 5.5 mm for OSEM-TOF+PSF. In the patient validation, the maximum percentage difference in lesion quantification between standard and optimized protocol (whole-body scan time of 15 vs. 5 min) was below 19%. CONCLUSIONS: A reduction of single-bed and whole-body scan time for [68Ga]Ga-PSMA PET/CT compared to current recommended clinical acquisition protocols is postulated. Clinical studies are warranted to validate the applicability of this protocol.


Asunto(s)
Radioisótopos de Galio , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Computarizada por Rayos X , Factores de Tiempo , Fantasmas de Imagen
2.
J Nucl Cardiol ; 30(1): 101-111, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-35562639

RESUMEN

INTRODUCTION: Transthyretin (ATTR) amyloidosis is responsible for the majority of cardiac amyloidosis (CA) cases and can be reliably diagnosed with bone scintigraphy and the visual Perugini score. We aimed to implement a quantification method of cardiac amyloid deposits in patients with suspected cardiac amyloidosis and to compare performance to visual scoring. METHODS AND MATERIALS: 136 patients received 99mTc-DPD-bone scintigraphy including SPECT/CT of the thorax in case of suspicion of cardiac amyloidosis. Imaging phantom studies were performed to determine the scaling factor for standardized uptake value (SUV) quantification from SPECT/CT. Myocardial tracer uptake was quantified in a whole heart volume of interest. RESULTS: Forty-five patients were diagnosed with CA. A strong relationship between cardiac SUVmax and Perugini score was found (Spearman r 0.75, p < 0.0001). Additionally, tracer uptake in bone decreased with increasing cardiac SUVmax and Perugini score (p < 0.0001). ROC analysis revealed good performance of the SUVmax for the detection of ATTR-CA with AUC of 0.96 ± 0.02 (p < 0.0001) with sensitivity 98.7% and specificity 87.2%. CONCLUSION: We demonstrate an accessible and accurate quantitative SPECT approach in CA. Quantitative assessment of the cardiac tracer uptake may improve diagnostic accuracy and risk classification. This method may enable monitoring and assessment of therapy response in patients with ATTR amyloidosis.


Asunto(s)
Amiloidosis , Cardiomiopatías , Humanos , Corazón , Prealbúmina , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía Computarizada de Emisión de Fotón Único , Tomografía Computarizada por Rayos X
3.
Eur J Nucl Med Mol Imaging ; 49(2): 460-469, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34218300

RESUMEN

INTRODUCTION: While [177Lu]Lu-PSMA radioligand therapy is currently only applied in end-stage metastatic castrate-resistant prostate cancer (mCRPC) patients, also low-volume hormone-sensitive metastatic prostate cancer (mHSPC) patients can benefit from it. However, there are toxicity concerns related to the sink effect in low-volume disease. This prospective study aims to determine the kinetics of [177Lu]Lu-PSMA in mHSPC patients, analyzing the doses to organs at risk (salivary glands, kidneys, liver, and bone marrow) and tumor lesions < 1 cm diameter. METHODS: Ten mHSPC patients underwent two cycles of [177Lu]Lu-PSMA therapy. Three-bed position SPECT/CT was performed at 5 time points after each therapy. Organ dosimetry and lesion dosimetry were performed using commercial software and a manual approach, respectively. Correlation between absorbed index lesion dose and treatment response (PSA drop of > 50% at the end of the study) was calculated and given as Spearman's r and p-values. RESULTS: Kinetics of [177Lu]Lu-PSMA in mHSPC patients are comparable to those in mCRPC patients. Lesion absorbed dose was high (3.25 ± 3.19 Gy/GBq) compared to organ absorbed dose (salivary glands: 0.39 ± 0.17 Gy/GBq, kidneys: 0.49 ± 0.11 Gy/GBq, liver: 0.09 ± 0.01 Gy/GBq, bone marrow: 0.017 ± 0.008 Gy/GBq). A statistically significant correlation was found between treatment response and absorbed index lesion dose (p = 0.047). CONCLUSIONS: We successfully performed small lesion dosimetry and showed that the tumor sink effect in mHSPC patients is of less concern than was expected. Tumor-to-organ ratio of absorbed dose was high and tumor uptake correlates with PSA response. Additional treatment cycles are legitimate in terms of organ toxicity and could lead to better tumor response.


Asunto(s)
Lutecio , Antígeno Prostático Específico , Neoplasias de la Próstata , Radiofármacos , Hormonas/metabolismo , Humanos , Lutecio/efectos adversos , Lutecio/farmacocinética , Lutecio/uso terapéutico , Masculino , Órganos en Riesgo/diagnóstico por imagen , Órganos en Riesgo/efectos de la radiación , Estudios Prospectivos , Antígeno Prostático Específico/efectos adversos , Antígeno Prostático Específico/sangre , Antígeno Prostático Específico/farmacocinética , Antígeno Prostático Específico/uso terapéutico , Neoplasias de la Próstata/sangre , Neoplasias de la Próstata/metabolismo , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/secundario , Dosis de Radiación , Radiofármacos/efectos adversos , Radiofármacos/farmacocinética , Radiofármacos/uso terapéutico , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Resultado del Tratamiento
4.
Eur J Nucl Med Mol Imaging ; 49(10): 3373-3386, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35412053

RESUMEN

PURPOSE: The determination of the glomerular filtration rate (GFR) is decisive for a variety of clinical issues, for example, to monitor the renal function in radionuclide therapy patients. Renal scintigraphy using glomerularly filtered tracers allows combined acquisition of renograms and GFR estimation but requires repeated blood sampling for several hours. In contrast, dynamic PET imaging using the glomerularly filtered tracer [68Ga]Ga-DOTA bears the potential to non-invasively estimate the GFR by compartmental kinetic modelling. Here, we report the, to our knowledge, first comparison of human renal dynamic [68Ga]Ga-DOTA PET imaging in comparison to renal scintigraphy and compare PET-derived to serum creatinine-derived GFR measurements. METHODS: Dynamic [68Ga]Ga-DOTA PET data were acquired for 30 min immediately after tracer injection in 12 patients. PET and renal scintigraphy images were visually interpreted in a consensus read by three nuclear medicine physicians. The functional renal cortex was segmented to obtain time-activity curves. The arterial input function was estimated from the PET signal in the abdominal aorta. Single-compartmental tracer kinetic modelling was performed to calculate the GFR using complete 30-min (GFRPET-30) and reduced 15-min PET data sets (GFRPET-15) to evaluate whether a shorter acquisition time is sufficient for an accurate GFR estimation. A modified approach excluding minutes 2 to 10 was applied to reduce urinary spill-over effects. Serum creatinine-derived GFRCKD (CKD-EPI-formula) was used as reference standard. RESULTS: PET image interpretation revealed the same findings as conventional scintigraphy (2/12 patients with both- and 1/12 patients with right-sided urinary obstruction). Model fit functions were substantially improved for the modified approach to exclude spill-over. Depending on the modelling approach, GFRCKD and both GFRPET-30 and GFRPET-15 were well correlated with interclass correlation coefficients (ICCs) from 0.74 to 0.80 and Pearson's correlation coefficients (PCCs) from 0.74 to 0.81. For a subgroup of patients with undisturbed urinary efflux (n = 9), correlations were good to excellent (ICCs from 0.82 to 0.95 and PCCs from 0.83 to 0.95). Overall, GFRPET-30 and GFRPET-15 were excellently correlated (ICCs from 0.96 to 0.99 and PCCs from 0.96 to 0.99). CONCLUSION: Renal [68Ga]Ga-DOTA PET can be a suitable alternative to conventional scintigraphy. Visual assessment of PET images and conventional renograms revealed comparable results. GFR values derived by non-invasive single-compartmental-modelling of PET data show a good correlation to serum creatinine-derived GFR values. In patients with undisturbed urinary efflux, the correlation was excellent. Dynamic PET data acquisition for 15 min is sufficient for visual evaluation and GFR derivation.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Insuficiencia Renal Crónica , Creatinina , Radioisótopos de Galio , Tasa de Filtración Glomerular , Compuestos Heterocíclicos con 1 Anillo , Humanos , Riñón/diagnóstico por imagen , Riñón/fisiología , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos
5.
Eur J Nucl Med Mol Imaging ; 49(4): 1101-1112, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34623453

RESUMEN

INTRODUCTION: Patient eligibility for [177Lu]Lu-PSMA therapy remains a challenge, with only 40-60% response rate when patient selection is done based on the lesion uptake (SUV) on [68Ga]Ga-PSMA-PET/CT. Prediction of absorbed dose based on this pre-treatment scan could improve patient selection and help to individualize treatment by maximizing the absorbed dose to target lesions while adhering to the threshold doses for the organs at risk (kidneys, salivary glands, and liver). METHODS: Ten patients with low-volume hormone-sensitive prostate cancer received a pre-therapeutic [68Ga]Ga-PSMA-11 PET/CT, followed by 3 GBq [177Lu]Lu-PSMA-617 therapy. Intra-therapeutically, SPECT/CT was acquired at 1, 24, 48, 72, and 168 h. Absorbed dose in organs and lesions (n = 22) was determined according to the MIRD scheme. Absorbed dose prediction based on [68Ga]Ga-PSMA-PET/CT was performed using tracer uptake at 1 h post-injection and the mean tissue effective half-life on SPECT. Predicted PET/actual SPECT absorbed dose ratios were determined for each target volume. RESULTS: PET/SPECT absorbed dose ratio was 1.01 ± 0.21, 1.10 ± 0.15, 1.20 ± 0.34, and 1.11 ± 0.29 for kidneys (using a 2.2 scaling factor), liver, submandibular, and parotid glands, respectively. While a large inter-patient variation in lesion kinetics was observed, PET/SPECT absorbed dose ratio was 1.3 ± 0.7 (range: 0.4-2.7, correlation coefficient r = 0.69, p < 0.01). CONCLUSION: A single time point [68Ga]Ga-PSMA-PET scan can be used to predict the absorbed dose of [177Lu]Lu-PSMA therapy to organs, and (to a limited extent) to lesions. This strategy facilitates in treatment management and could increase the personalization of [177Lu]Lu-PSMA therapy.


Asunto(s)
Radioisótopos de Galio , Neoplasias de la Próstata Resistentes a la Castración , Dipéptidos , Compuestos Heterocíclicos con 1 Anillo , Humanos , Lutecio , Masculino , Órganos en Riesgo/patología , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones , Antígeno Prostático Específico , Neoplasias de la Próstata Resistentes a la Castración/patología , Radiofármacos/uso terapéutico
6.
BMC Cancer ; 22(1): 899, 2022 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-35978274

RESUMEN

BACKGROUND: New-generation silicon-photomultiplier (SiPM)-based PET/CT systems exhibit an improved lesion detectability and image quality due to a higher detector sensitivity. Consequently, the acquisition time can be reduced while maintaining diagnostic quality. The aim of this study was to determine the lowest 18F-FDG PET acquisition time without loss of diagnostic information and to optimise image reconstruction parameters (image reconstruction algorithm, number of iterations, voxel size, Gaussian filter) by phantom imaging. Moreover, patient data are evaluated to confirm the phantom results. METHODS: Three phantoms were used: a soft-tissue tumour phantom, a bone-lung tumour phantom, and a resolution phantom. Phantom conditions (lesion sizes from 6.5 mm to 28.8 mm in diameter, lesion activity concentration of 15 kBq/mL, and signal-to-background ratio of 5:1) were derived from patient data. PET data were acquired on an SiPM-based Biograph Vision PET/CT system for 10 min in list-mode format and resampled into time frames from 30 to 300 s in 30-s increments to simulate different acquisition times. Different image reconstructions with varying iterations, voxel sizes, and Gaussian filters were probed. Contrast-to-noise-ratio (CNR), maximum, and peak signal were evaluated using the 10-min acquisition time image as reference. A threshold CNR value ≥ 5 and a maximum (peak) deviation of ± 20% were considered acceptable. 20 patient data sets were evaluated regarding lesion quantification as well as agreement and correlation between reduced and full acquisition time standard uptake values (assessed by Pearson correlation coefficient, intraclass correlation coefficient, Bland-Altman analyses, and Krippendorff's alpha). RESULTS: An acquisition time of 60 s per bed position yielded acceptable detectability and quantification results for clinically relevant phantom lesions ≥ 9.7 mm in diameter using OSEM-TOF or OSEM-TOF+PSF image reconstruction, a 4-mm Gaussian filter, and a 1.65 × 1.65 x 2.00-mm3 or 3.30 × 3.30 x 3.00-mm3 voxel size. Correlation and agreement of patient lesion quantification between full and reduced acquisition times were excellent. CONCLUSION: A threefold reduction in acquisition time is possible. Patients might benefit from more comfortable examinations or reduced radiation exposure, if instead of the acquisition time the applied activity is reduced.


Asunto(s)
Fluorodesoxiglucosa F18 , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Fantasmas de Imagen , Tomografía de Emisión de Positrones
7.
BMC Cancer ; 21(1): 62, 2021 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-33446147

RESUMEN

BACKGROUND: The superior accuracy and sensitivity of 18F-FDG-PET/CT in comparison to morphological imaging alone leads to an upstaging in up to 30% of lymphoma patients. Novel digital PET/CT scanners might enable to reduce administered tracer activity or scan time duration while maintaining diagnostic performance; this might allow for a higher patient throughput or a reduced radiation exposure, respectively. In particular, the radiation exposure reduction is of interest due to the often young age and high remission rate of lymphoma patients. METHODS: Twenty patients with (suspected) lymphoma (6 for initial staging, 12 after systemic treatment, 2 in suspicion of recurrence) sequentially underwent 18F-FDG-PET/CT examinations on a digital PET/CT (Siemens Biograph Vision) with a total scan time duration of 15 min (reference acquisition protocol) and 5 min (reduced acquisition protocol) using continuous-bed-motion. Both data sets were reconstructed using either standalone time of flight (TOF) or in combination with point spread function (PSF), each with 2 and 4 iterations. Lesion detectability by blinded assessment (separately for supra- and infradiaphragmal nodal lesions and for extranodal lesions), lesion image quantification, and image noise were used as metrics to assess diagnostic performance. Additionally, Deauville Score was compared for all patients after systemic treatment. RESULTS: All defined regions were correctly classified in the images acquired with reduced emission time, and therefore, no changes in staging were observed. Lesion quantification was acceptable, that is, mean absolute percentage deviation of maximum and peak standardized uptake values were 6.8 and 6.4% (derived from 30 lesions). A threefold reduction of scan time duration led to an increase in image noise from 7.1 to 11.0% (images reconstructed with 4 iterations) and from 4.7 to 7.2% (images reconstructed with 2 iterations). No deviations in Deauville Score were observed. CONCLUSION: These results suggest that scan time duration or administered tracer activity can be reduced threefold without compromising diagnostic performance. Especially a reduction of administered activity might allow for a lower radiation exposure and better health economics. Larger trials are warranted to confirm our results.


Asunto(s)
Fluorodesoxiglucosa F18/metabolismo , Procesamiento de Imagen Asistido por Computador/métodos , Linfoma/patología , Tomografía Computarizada por Tomografía de Emisión de Positrones/instrumentación , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Radiofármacos/metabolismo , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Linfoma/diagnóstico por imagen , Linfoma/metabolismo , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Adulto Joven
8.
Eur J Nucl Med Mol Imaging ; 46(7): 1439-1447, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30710323

RESUMEN

PURPOSE: According to the ACRIN 6668/RTOG 0235 trial, pretreatment metabolic tumour volume (MTV) as detected by 18F-fluorodeoxyglucose PET/CT is a prognostic factor in patients with stage III non-small-cell lung cancer (NSCLC) after definitive radiochemotherapy (RCT). To validate the prognostic value of MTV in patients with stage III NSCLC after RCT, we analysed mature survival data from the German phase III trial ESPATUE. METHODS: This analysis included patients who were staged by PET/CT and who were enrolled in the ESPATUE trial, a randomized study comparing definitive RCT (arm A) with surgery (arm B) after induction chemotherapy and RCT in patients with resectable stage IIIA/IIIB NSCLC. Patients refusing surgery and those with nonresectable disease were scheduled to receive definitive RCT. MTV was measured using a fixed threshold-based approach and a model-based iterative volume thresholding approach. Data were analysed using proportional hazards models and Kaplan-Meier survival functions. RESULTS: MTV as a continuous variable did not reveal differences in survival between the 117 patients scheduled to receive definitive RCT and all 169 enrolled patients who underwent pretreatment PET/CT (p > 0.5). Five-year survival rates were 33% (95% CI 17-49%) in patients scheduled for definitive RCT with a high MTV (>95.4 ml) and 32% (95% CI: 22-42%) in those with a low MTV. The hazard ratio for survival was 0.997 (95% CI 0.973-1.022) per 10-ml increase in MTV and the slope was significantly shallower than that in the ACRIN 6668/RTOG 0235 trial (random effects model, p = 0.002). There were no differences in MTV size distributions between the ACRIN and ESPATUE trials (p = 0.97). CONCLUSION: Patients with stage III NSCLC and a large MTV in whom definitive RCT had a particularly good survival in the ESPATUE trial. Treatment individualization according to MTV is not supported by this study. The ESPATUE and ACRIN trials differed by the use of cisplatin-containing induction chemotherapy and an intensified radiotherapy regimen that were particularly effective in patients with large MTV disease.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Quimioradioterapia/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones , Adulto , Anciano , Carcinoma de Pulmón de Células no Pequeñas/mortalidad , Carcinoma de Pulmón de Células no Pequeñas/terapia , Terapia Combinada , Femenino , Fluorodesoxiglucosa F18 , Alemania , Humanos , Quimioterapia de Inducción , Estimación de Kaplan-Meier , Neoplasias Pulmonares/mortalidad , Neoplasias Pulmonares/terapia , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Pronóstico , Modelos de Riesgos Proporcionales , Radiofármacos/uso terapéutico , Resultado del Tratamiento , Carga Tumoral
9.
Q J Nucl Med Mol Imaging ; 63(3): 235-252, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31298014

RESUMEN

Radioiodine therapy of thyroid cancer was the first successful radionuclide therapy in the treatments of cancer, although its clinical use is empirical and not based on precise dosimetry. 124I is a positron-emitting radionuclide and positron emission tomography/computed tomography (PET/CT) with 124I currently provides the most accurate estimation of the absorbed (radiation) dose to thyroid cancer lesions. In the application, serial 124I PET/CT scans are performed to determine the time uptake curves and to delineate the volumes of the lesions. The 124I data are then used to project the absorbed dose per unit administered 131I activity. The results are part of the decision-making process to individually guide treatment plans, in particular by tailoring the therapeutic 131I activity in radioiodine therapy. The aim of this review is to provide an overview of 124I PET/CT lesion dosimetry of differentiated thyroid cancer including: 1) an historical overview; 2) the general properties of 124I and its activity measurement; 3) the main factors impairing PET image quantification; 4) an optimized lesion dosimetry protocol used in our group to make this manuscript self-contained; as well as 5) a summary of important clinical studies.


Asunto(s)
Radioisótopos de Yodo , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Neoplasias de la Tiroides/diagnóstico por imagen , Humanos , Radiometría , Neoplasias de la Tiroides/patología
10.
Q J Nucl Med Mol Imaging ; 61(3): 331-339, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25566809

RESUMEN

BACKGROUND: A retrospective study using PET/CT imaging with 124I-labeled metaiodobenzylguanidine (124I-MIBG) was performed to estimate the (radiation) absorbed dose to the salivary glands in neuroendocrine cancer patients undergoing 131I-MIBG therapy and to compare these results with those in radioiodine (131I-iodide) therapy. METHODS: Twenty-seven patients received individual 124I-MIBG-PET/CT dosimetries, among whom 18 had not previously undergone any MIBG therapies (patient group before treatment) and 9 had already received MIBG therapies prior to the tracer dosimetries (patient group after treatment). For each patient, three or four 124I-MIBG PET/CT scans were performed at approximately 4 and 24 hours, as well as at approximately 48 or/and ≥96 hours after tracer injection. The absorbed doses per administered 131I-MIBG activity to the submandibular and parotid glands were calculated based on the MIRD concept, with its assumption of a uniform glandular activity distribution. RESULTS: The mean±standard deviation of the (self-)absorbed dose per activity averaged over both patient groups and salivary gland types was 0.53±0.24 Gy/GBq (median, 0.49 Gy/GBq; range, 0.17-1.38 Gy/GBq). The absorbed doses per activity of the patient group before treatment did not significantly deviate from those of the patient group after treatment (P=0.67). In the patient group after treatment, the mean±standard deviation of the cumulative 131I-MIBG activity was 20±12 GBq (median, 16 GBq; range, 10-50 GBq). Among the patient groups, no significant absorbed dose difference was found between the submandibular and parotid glands (P>0.24). In comparison to radioiodine therapy, the estimated absorbed dose per activity in MIBG was significantly higher (P<0.001), on average twice as high, contradicting the relationship between the absorbed dose and clinical observation of glandular side effects. CONCLUSIONS: The discrepant salivary gland responses in MIBG and radioiodine therapies suggest a different radiotherapeutical distribution on microscopic scale within the glandular tissue and prove the clinical relevance of a microdosimetric analysis.


Asunto(s)
3-Yodobencilguanidina/efectos adversos , Radioisótopos de Yodo/efectos adversos , Glándulas Salivales/efectos de la radiación , 3-Yodobencilguanidina/uso terapéutico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Animales , Carcinoma Neuroendocrino/diagnóstico por imagen , Carcinoma Neuroendocrino/radioterapia , Niño , Femenino , Humanos , Radioisótopos de Yodo/uso terapéutico , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Tomografía de Emisión de Positrones , Dosis de Radiación , Estudios Retrospectivos , Glándulas Salivales/diagnóstico por imagen , Adulto Joven
11.
Inorg Chem ; 55(12): 6294-9, 2016 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-27276239

RESUMEN

Procedures for the purification and subsequent crystallization of the slightly soluble four-coordinate metallporphines, the simplest possible porphyrin derivatives, are described. Crystals of the porphine derivatives of cobalt(II), copper(II), platinum(II), and two polymorphs of zinc(II) were obtained. Analysis of the crystal and molecular structures shows that all except the platinum(II) derivative form an unusual trimeric species in the solid state. The isomorphous cobalt(II), copper(II), and one zinc(II) polymorph pack in the unit cell to form dimers as well as the trimers. Interplanar spacings between porphine rings are similar in both the dimers and trimers and range between 3.24 and 3.37 Å. Porphine rings are strongly overlapped with lateral shifts between ring centers in both the dimers and trimers with values between 1.52 and 1.70 Å or in Category S as originally defined by Scheidt and Lee. Periodic trends in the M-Np bond distances parallel those observed previously for tetraphenyl- and octaethylporphyrin derivatives.

12.
Phys Med Biol ; 69(16)2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-38925139

RESUMEN

Objective.The partial-volume effect (PVE) is an important factor impairing tumour quantification in molecular imaging. The commonly used contour-volume-of-interest (contour-VOI) approach to correct for this effect employs phantom-based recovery coefficients. Applying oversize-VOIs could offer superior quantification accuracy in small lesions. The oversize-VOI approach uses a large oversize volume to determine the total tumour activity after applying a background correction. Aims of this study were to provide a procedure for the application of the oversize-VOI approach and to compare its performance to the contour-VOI approach in PET imaging.Approach.A sphere tumour model was simulated to determine the oversize diameter that contained 90%, 95%, and 98% of the total activity as a function of the tumour size. Experimental investigations involving phantom and clinical data were conducted on a digital PET/CT scanner. In the phantom investigation, 12 spherical tumour inserts (diameters ranging from 3.7 to 37.4 mm) containing18F-solution were used. The accuracy of the contour- and oversize-VOI approach was evaluated for different signal-to-background ratios (20-3). Clinically, both approaches were applied on PET/CT images acquired with18F-labelled prostate-specific membrane antigen in prostate cancer patients.Main results.From the tumour model, we deduced that an oversize-VOI of two PET spatial resolutions larger than the physical lesion diameter contains at least 98% of the total activity for lesions with diameters down to one PET spatial resolution, while minimizing the background contribution. Both approaches were robust against varying phantom and clinical imaging conditions. Performance of the oversize-VOI approach was favorable for lesions below 10 mm in diameter, whereas the contour-VOI approach was slightly more accurate for sizes above 10 mm.Significance.The oversize-VOI approach facilitates image quantification of small tumours. It is simple and effective to correct for the PVE and may be used in pre-therapeutic (small) tumour dosimetry.


Asunto(s)
Fantasmas de Imagen , Tomografía de Emisión de Positrones , Radiometría , Planificación de la Radioterapia Asistida por Computador , Planificación de la Radioterapia Asistida por Computador/métodos , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Procesamiento de Imagen Asistido por Computador/métodos , Carga Tumoral , Dosificación Radioterapéutica , Neoplasias/radioterapia , Neoplasias/diagnóstico por imagen
13.
EJNMMI Phys ; 11(1): 3, 2024 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-38167953

RESUMEN

AIM: Positron emission tomography (PET) using 124I-mIBG has been established for imaging and pretherapeutic dosimetry. Here, we report the first systematic analysis of the biodistribution and radiation dosimetry of 124I-mIBG in patients with neural crest tumours and project the results to paediatric patient models. METHODS: Adult patients with neural crest tumours who underwent sequential 124I-mIBG PET were included in this retrospective single-center analysis. PET data were acquired 4, 24, 48, and/or 120 h after administration of a mean of 43 MBq 124I-mIBG. Whole-body counting and blood sampling were performed at 2, 4, 24, 48 and 120 h after administration. Absorbed organ dose and effective dose coefficients were estimated in OLINDA/EXM 2.2 according to the MIRD formalism. Extrapolation to paediatric models was performed based on mass-fraction scaling of the organ-specific residence times. Biodistribution data for adults were also projected to 123I-mIBG and 131I-mIBG. RESULTS: Twenty-one patients (11 females, 10 males) were evaluated. For adults, the organs exposed to the highest dose per unit administered activity were urinary bladder (1.54 ± 0.40 mGy/MBq), salivary glands (0.77 ± 0.28 mGy/MBq) and liver (0.65 ± 0.22 mGy/MBq). Mean effective dose coefficient for adults was 0.25 ± 0.04 mSv/MBq (male: 0.24 ± 0.03 mSv/MBq, female: 0.26 ± 0.06 mSv/MBq), and increased gradually to 0.29, 0.44, 0.69, 1.21, and 2.94 mSv/MBq for the 15-, 10-, 5-, 1-years-old, and newborn paediatric reference patients. Projected mean effective dose coefficients for 123I-mIBG and 131I-mIBG for adults were 0.014 ± 0.002 mSv/MBq and 0.18 ± 0.04 mSv/MBq, respectively. CONCLUSION: PET-based derived radiation dosimetry data for 124I-mIBG from this study agreed well with historical projected data from ICRP 53. The effective dose coefficients presented here may aid in guidance for establishing weight-based activity administration protocols.

14.
J Nucl Med ; 65(1): 71-78, 2024 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-38050121

RESUMEN

In the VISION trial, [177Lu]Lu-PSMA-617 (177Lu-PSMA-617) plus protocol-permitted standard of care significantly improved overall survival and radiographic progression-free survival compared with standard of care alone in patients with prostate-specific membrane antigen-positive metastatic castration-resistant prostate cancer. This VISION dosimetry substudy quantified absorbed doses of 177Lu-PSMA-617 in the kidneys and other organs. Methods: Participants were a separate cohort of 30 nonrandomized patients receiving standard of care plus 177Lu-PSMA-617 at 7.4 GBq per cycle for up to 6 cycles. Blood samples, whole-body conjugate planar image scintigraphy, and abdominal SPECT/CT images were collected. SPECT/CT images were collected at 2, 24, 48, and 168 h after administration in cycle 1 and at a single time point 48 h after administration in cycles 2-6. Outcomes were absorbed dose per unit activity per cycle and cumulative absorbed dose over all cycles. Cumulative absorbed doses were predicted by extrapolation from cycle 1, and calculation of observed values was based on measurements of cycle 1 and cycles 2-6. Safety was also assessed. Results: Mean (±SD) absorbed doses per cycle in the kidneys were 0.43 ± 0.16 Gy/GBq in cycle 1 and 0.44 ± 0.21 Gy/GBq in cycles 2-6. The observed and predicted 6-cycle cumulative absorbed doses in the kidneys were 15 ± 6 and 19 ± 7 Gy, respectively. Observed and predicted cumulative absorbed doses were similar in other at-risk organs. Safety findings were consistent with those in the VISION study; no patients experienced renal treatment-emergent adverse events of a grade higher than 3. Conclusion: The renal cumulative absorbed 177Lu-PSMA-617 dose was below the established limit. 177Lu-PSMA-617 had a good overall safety profile, and low renal radiotoxicity was not a safety concern. Cumulative absorbed doses in at-risk organs over multiple cycles can be predicted by extrapolation from cycle 1 data in patients with metastatic castration-resistant prostate cancer receiving 177Lu-PSMA-617.


Asunto(s)
Neoplasias de la Próstata Resistentes a la Castración , Masculino , Humanos , Neoplasias de la Próstata Resistentes a la Castración/radioterapia , Neoplasias de la Próstata Resistentes a la Castración/patología , Radiofármacos/efectos adversos , Dipéptidos/efectos adversos , Antígeno Prostático Específico , Compuestos Heterocíclicos con 1 Anillo/efectos adversos , Riñón , Lutecio/efectos adversos
15.
J Nucl Med ; 65(6): 931-937, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38637142

RESUMEN

Para-aminohippurate, also known as p-aminohippuric acid (PAH), is used clinically to measure effective renal plasma flow. Preclinically, it was shown to reduce 177Lu-DOTATOC uptake in the kidneys while improving bioavailability compared with amino acid (AA) coinfusion. We report the safety and efficacy of PAH coinfusion during peptide receptor radiotherapy in patients with neuroendocrine tumors. Methods: Twelve patients with metastatic or unresectable gastroenteropancreatic neuroendocrine tumors received 177Lu-DOTATOC in 33 treatment cycles. Either 8 g of PAH or a mixture of 25 g of arginine and 25 g of lysine were coinfused. Safety was assessed by monitoring laboratory data, including hematologic and renal data, as well as electrolytes obtained before and 24 h after treatment. For radiation dosimetry, whole-body scans were performed at 1, 24, and 48 h and a SPECT/CT scan was performed at 48 h, along with blood sampling at 5 min and 0.5, 2, 4, 24, and 48 h after administration. Absorbed dose estimations for the kidneys and bone marrow were performed according to the MIRD concept. Results: In 15 treatment cycles, PAH was coinfused. No changes in mean creatinine level, glomerular filtration rate, and serum electrolytes were observed before or 24 h after treatment when using PAH protection (P ≥ 0.20), whereas serum chloride and serum phosphate increased significantly under AA (both P < 0.01). Kidney-absorbed dose coefficients were 0.60 ± 0.14 Gy/GBq with PAH and 0.53 ± 0.16 Gy/GBq with AA. Based on extrapolated cumulative kidney-absorbed doses for 4 cycles, 1 patient with PAH protection and 1 patient with AA protection in our patient group would exceed the 23-Gy conservative threshold. The bone marrow-absorbed dose coefficient was 0.012 ± 0.004 Gy/GBq with PAH and 0.012 ± 0.003 Gy/GBq with AA. Conclusion: PAH is a promising alternative to AA for renal protection during peptide receptor radiotherapy. Further research is required to systematically investigate the safety profile and radiation dosimetry at varying PAH plasma concentrations.


Asunto(s)
Riñón , Tumores Neuroendocrinos , Octreótido , Humanos , Tumores Neuroendocrinos/radioterapia , Tumores Neuroendocrinos/metabolismo , Masculino , Femenino , Persona de Mediana Edad , Anciano , Octreótido/análogos & derivados , Octreótido/uso terapéutico , Octreótido/efectos adversos , Riñón/efectos de la radiación , Riñón/metabolismo , Receptores de Péptidos/metabolismo , Adulto , Protección Radiológica , Seguridad , Compuestos Organometálicos/uso terapéutico , Compuestos Organometálicos/efectos adversos
16.
Phys Med ; 114: 103149, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37778973

RESUMEN

PURPOSE: The aim of this study was to investigate conditions for reliable quantification of sub-centimeter lesions with low18F,68Ga, and124I uptake using a silicon photomultiplier-based PET/CT system. METHODS: A small tumor phantom was investigated under challenging but clinically realistic conditions resembling prostate and thyroid cancer lymph node metastases (6 spheres with 3.7-9.7 mm in diameter, 9 different activity concentrations ranging from about 0.25-25 kBq/mL, and a signal-to-background ratio of 20). Radionuclides with different positron branching ratios and prompt gamma coincidence contributions were investigated. Maximum-, contour-, and oversize-based partial volume effect (PVE) correction approaches were applied. Detection and quantification performance were estimated, considering a ±30 % deviation between imaged-derived and true activity concentrations as acceptable. A standard and a prolonged acquisition time and two image reconstruction algorithms (time-of-flight with/without point spread function modelling) were analyzed. Clinical data were evaluated to assess agreement of PVE-correction approaches indicating lesion quantification validity. RESULTS: The smallest 3.7-mm sphere was not visible. If the lesions were clearly observed, quantification was, except for a few cases, acceptable using contour- or oversized-based PVE-corrections. Quantification accuracy did not substantially differ between 18F, 68Ga, and 124I. No systematic differences between the analyzed reconstruction algorithms or shorter and larger acquisition times were observed. In the clinical evaluation of 20 lesions, an excellent statistical agreement between oversize- and contour-based PVE-corrections was observed. CONCLUSIONS: At the lower end of size (<10 mm) and activity concentration ranges of lymph-node metastases, quantification with reasonable accuracy is possible for 18F, 68Ga, and 124I, possibly allowing pre-therapeutic lesion dosimetry and individualized radionuclide therapy planning.


Asunto(s)
Radioisótopos de Galio , Tomografía Computarizada por Tomografía de Emisión de Positrones , Masculino , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Radioisótopos de Yodo/uso terapéutico , Radiometría , Tomografía de Emisión de Positrones
17.
J Nucl Med ; 64(6): 885-891, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36732054

RESUMEN

We aim to evaluate the efficacy and safety of 124I-metaiodobenzylguanidine (MIBG) dosimetry-guided high-activity 131I-MIBG therapy of advanced pheochromocytoma or neuroblastoma. Methods: Fourteen patients with advanced pheochromocytoma or neuroblastoma, age 9-69 y, underwent 124I-MIBG PET scans and whole-body retention measurements to assess the whole-body dose as a surrogate of bone marrow toxicity and tumor (absorbed) dose per unit of administered activity. Dosimetry results together with individual patient characteristics were combined to guide a single therapeutic activity to achieve a high tumor dose without exceeding toxicity threshold. Toxicity was assessed for hematologic, hepatic, and renal function. Response was evaluated by RECIST, International Society of Pediatric Oncology Europe Neuroblastoma-like score, change in PET uptake, and quantitative PET parameters (SUVmax, SUVpeak, metabolic tumor volume, total lesion glycolysis), as well as visual decrease in number or in visual intensity of lesions on baseline to follow-up 124I-MIBG PET/CT. Results: The average therapeutic activity was 14 GBq. Eleven of 14 patients (79%) received each more than 10 GBq. One male patient was treated with a single activity of 50 GBq. Three patients were treated with lower activities between 3.5 and 7.0 GBq. Median overall survival was 85 mo (95% CI), and median progression-free survival was 25 mo (95% CI). Four (29%) and 5 (36%) patients demonstrated response (complete response or partial response) by RECIST and functional imaging, respectively. One patient exceeded whole-body dose of 2 Gy and demonstrated grade 3 hematologic toxicity, which resolved spontaneously within 12 mo after the therapy without the need for further treatment. Three patients (21%) demonstrated transient grade 1 renal toxicity. Conclusion: 124I-MIBG dosimetry-guided high-activity 131I-MIBG therapy in patients with advanced pheochromocytoma or neuroblastoma resulted in durable responses with a low rate of manageable adverse events. Efficacy of 124I-MIBG-guided activity escalation should further be assessed in a prospective setting.


Asunto(s)
Neoplasias de las Glándulas Suprarrenales , Neuroblastoma , Feocromocitoma , Niño , Humanos , Masculino , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , 3-Yodobencilguanidina/efectos adversos , Feocromocitoma/diagnóstico por imagen , Feocromocitoma/radioterapia , Tomografía Computarizada por Tomografía de Emisión de Positrones , Estudios Prospectivos , Neuroblastoma/diagnóstico por imagen , Neuroblastoma/radioterapia , Neoplasias de las Glándulas Suprarrenales/diagnóstico por imagen , Neoplasias de las Glándulas Suprarrenales/radioterapia
18.
J Nucl Med ; 64(2): 329-336, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-35981898

RESUMEN

Therapy with 90Y-labeled fibroblast activation protein inhibitors (90Y-FAPIs) was recently introduced as a novel treatment concept for patients with solid tumors. Lesion and organ-at-risk dosimetry is part of assessing treatment efficacy and safety and requires reliable quantification of tissue uptake. As 90Y quantification is limited by the low internal positron-electron pair conversion rate, the increased effective sensitivity of digital silicon photomultiplier-based PET/CT systems might increase quantification accuracy and, consequently, allow for dosimetry in 90Y-FAPI therapy. The aim of this study was to explore the conditions for reliable lesion image quantification in 90Y-FAPI radionuclide therapy using a digital PET/CT system. Methods: Two tumor phantoms were filled with 90Y solution using different sphere activity concentrations and a constant signal-to-background ratio of 40. The minimum detectable activity concentration was determined, and its dependence on acquisition time (15 vs. 30 min per bed position) and smoothing levels (all-pass vs. 5-mm gaussian filter) was investigated. Quantification accuracy was evaluated at various activity concentrations to estimate the minimum quantifiable activity concentration using contour-based and oversized volume-of-interest-based quantification approaches. A ±20% deviation range between image-derived and true activity concentrations was regarded as acceptable. Tumor dosimetry for 3 patients treated with 90Y-FAPI is presented to project the phantom results to clinical scenarios. Results: For a lesion size of 40 mm and a clinical acquisition time of 15 min, both minimum detectable and minimum quantifiable activity concentrations were 0.12 MBq/mL. For lesion sizes of greater than or equal to 30 mm, accurate quantification was feasible for detectable lesions. Only for the smallest 10-mm sphere, the minimum detectable and minimum quantifiable activity concentrations differ substantially (0.43 vs. 1.97 MBq/mL). No notable differences between the 2 quantification approaches were observed. For the investigated tumors, absorbed dose estimates with reliable accuracy were achievable. Conclusion: For lesion sizes and activity concentrations that are expected to be observed in patients treated with 90Y-FAPI, quantification with reasonable accuracy is possible. Further dosimetry studies are needed to thoroughly investigate the efficacy and safety of 90Y-FAPI therapy.


Asunto(s)
Neoplasias , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Radioisótopos de Itrio/uso terapéutico , Tomografía de Emisión de Positrones/métodos , Neoplasias/diagnóstico por imagen , Neoplasias/radioterapia , Neoplasias/tratamiento farmacológico , Fibroblastos , Radioisótopos de Galio
19.
EJNMMI Phys ; 9(1): 56, 2022 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-35984531

RESUMEN

AIM: To evaluate the effect of combining positron range correction (PRC) with point-spread-function (PSF) correction and to compare different methods of implementation into iterative image reconstruction for 124I-PET imaging. MATERIALS AND METHODS: Uniform PR blurring kernels of 124I were generated using the GATE (GEANT4) framework in various material environments (lung, water, and bone) and matched to a 3D matrix. The kernels size was set to 11 × 11 × 11 based on the maximum PR in water and the voxel size of the PET system. PET image reconstruction was performed using the standard OSEM algorithm, OSEM with PRC implemented before the forward projection (OSEM+PRC simplified) and OSEM with PRC implemented in both forward- and back-projection steps (full implementation) (OSEM+PRC). Reconstructions were repeated with resolution recovery, point-spread function (PSF) included. The methods and kernel variation were validated using different phantoms filled with 124I acquired on a Siemens mCT PET/CT system. The data was evaluated for contrast recovery and image noise. RESULTS: Contrast recovery improved by 2-10% and 4-37% with OSEM+PRC simplified and OSEM+PRC, respectively, depending on the sphere size of the NEMA IQ phantom. Including PSF in the reconstructions further improved contrast by 4-19% and 3-16% with the PSF+PRC simplified and PSF+PRC, respectively. The benefit of PRC was more pronounced within low-density material. OSEM-PRC and OSEM-PSF as well as OSEM-PSF+PRC in its full- and simplified implementation showed comparable noise and convergence. OSEM-PRC simplified showed comparably faster convergence but at the cost of increased image noise. CONCLUSIONS: The combination of the PSF and PRC leads to increased contrast recovery with reduced image noise compared to stand-alone PSF or PRC reconstruction. For OSEM-PRC reconstructions, a full implementation in the reconstruction is necessary to handle image noise. For the combination of PRC with PSF, a simplified PRC implementation can be used to reduce reconstruction times.

20.
Front Physiol ; 13: 818463, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35350691

RESUMEN

Aim: To develop and evaluate a new approach for spatially variant and tissue-dependent positron range (PR) correction (PRC) during the iterative PET image reconstruction. Materials and Methods: The PR distributions of three radionuclides (18F, 68Ga, and 124I) were simulated using the GATE (GEANT4) framework in different material compositions (lung, water, and bone). For every radionuclide, the uniform PR kernel was created by mapping the simulated 3D PR point cloud to a 3D matrix with its size defined by the maximum PR in lung (18F) or water (68Ga and 124I) and the PET voxel size. The spatially variant kernels were composed from the uniform PR kernels by analyzing the material composition of the surrounding medium for each voxel before implementation as tissue-dependent, point-spread functions into the iterative image reconstruction. The proposed PRC method was evaluated using the NEMA image quality phantom (18F, 68Ga, and 124I); two unique PR phantoms were scanned and evaluated following OSEM reconstruction with and without PRC using different metrics, such as contrast recovery, contrast-to-noise ratio, image noise and the resolution evaluated in terms of full width at half maximum (FWHM). Results: The effect of PRC on 18F-imaging was negligible. In contrast, PRC improved image contrast for the 10-mm sphere of the NEMA image quality phantom filled with 68Ga and 124I by 33 and 24%, respectively. While the effect of PRC was less noticeable for the larger spheres, contrast recovery still improved by 5%. The spatial resolution was improved by 26% for 124I (FWHM of 4.9 vs. 3.7 mm). Conclusion: For high energy positron-emitting radionuclides, the proposed PRC method helped recover image contrast with reduced noise levels and with improved spatial resolution. As such, the PRC approach proposed here can help improve the quality of PET data in clinical practice and research.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA